Preview only show first 10 pages with watermark. For full document please download

Spectrum Power Management Systems Catalog

   EMBED


Share

Transcript

SPECTRUM POWER MANAGEMENT SYSTEMS C Power Strips & Specialty Solutions Power Distribution for AC & DC Applications pical Applications • • • • • • • Data Centers Industrial ATE Cabinets Telecom Messaging Systems Scientific Instrumentation Cabinets Communication Base Stations Network Operating Centers Defense ATE Equipment Contact Us 1900 West College Avenue, State College, PA 16801 814-272-SPMS [email protected] www.specpower.com • • • • • • • • Portable Communications Equipment Rapid Deployment Racks Financial Centers Wireless Messaging Platforms Remote Sensors Solar Powered Infrastructures Wind Turbine Power Plants Oil Refineries Index Please click the appropriate headline and/or product description to view associated content What to Consider Before Selecting a Power Distribution Solution 4 Considerations for the Use of 3 Phase Wiring 5 Key Features & Benefits 6 Power Categories 7 Standard AC Power Strips 33” Power Strips NEMA Configurations Global Configurations Cordless Configurations 8 14 17 66” Power Strips NEMA Configurations Global Configurations 20 22 14” Satellites 24 Accessories 25 26 28 Cable Trays for Power Strips Optional Mounting Brackets Power Cords Specialty AC Power Solutions 72A-264BAHEN-02 / 72A-260BMHEN-02 72A-264BAXEN-02 / 72A-260BMXEN-02 7200-A-39S1 7200-A-39-3 72RA2A8BWFFN-00 / 72RA296BXFFN-00 72A-120BUHEM-71 72A-196BAREMS01 / 72A-190BQREMS01 AC SMARTStart® 7200-A-49 Specialty DC Power Solutions DC SMARTStart® & PMU 7400-DS79 7400-DS93 Data Acquisition & Power Monitoring 30 32 34 36 38 40 42 44 49 53 60 64 68 Quality Assurance 69 Request for Customer Specific Solution 70 AC and DC Product Offering Overview 71 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 2 Introduction Spectrum Power Management Systems is a well-respected manufacturer of power strips, power distribution units, and circuit protection systems for both AC and DC power applications. We have developed products as an OEM/ODM Global partner to the industry’s top names. SpecPower® has utilized the best of the OEM/ODM features to create a line of off-the-shelf (OTS) products which encompasses our AC Power Strips, AC and DC SMARTStart® Power Distribution Units, and a variety of specialty solutions. Our portfolio of AC Power Strips and and Specialty Solutions is created with the intent to offer a wide variety of options into a compact package that provides the client with many choices from which to choose the best configuration for the application. AC products are available with the choice of power monitoring (inclusive of visual display) or without monitoring. The monitoring feature provides for real time tracking of appliance power at the device. The monitoring includes a network interface to provide Telnet, SNMP, WEB or Serial RS232 remote power monitoring. Monitoring devices are becoming the industry preferred manner of getting closer to the actual cabinet and clearly knowing the health of the data center. The unmonitored units are an economical means to distribute bulk power to multiple appliances in a cabinet installation, while also providing reliable circuit protection. All of our products carry the UL/CE mark. The power distribution units are listed to UL60950-1, and circuit breakers are listed to UL489. UL489-listed circuit breakers are mandatory for use as primary branch disconnect protection. The use of circuit protection is truly valuable in most system installations to avoid the possibility of catastrophic system faults. Choosing the wrong type of circuit protection fuses or underrated circuit protection can result in major expenses that far exceed choosing the right power distribution solution. Thank you for your interest in Spectrum Power Management Systems. We believe our portfolio of AC Power Strips and Specialty Solutions will provide you the information needed to choose the best power distribution solution. If you find a product that needs to be tailored to fully accommodate your needs, we specialize in customized power distribution solutions. Speak to a Sales Representative today at 814-272-SPMS or email [email protected] to create your perfect power distribution solution! State College, Pennsylvania Location 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 3 What to Consider Before Selecting a Power Distribution Solution What are you powering? The number of devices needing power and the associated input cords determine the amount and types of outlets you need. Then, you must determine how much power must be supplied. We have a portfolio of products that provide anywhere from 2.40 to 22.08 KVA. For help determining the number of units required for your rack, refer to the table on page 7. Please carefully consider the loading characteristics of the application and the power capability of the actual site installation. It is most important that if selecting a 30 Amp single phase power strip, the power drop to the cabinet is indeed capable of handling such a load, and the same applies if you choose several power strips for such an installation. How much space is available? Do you have available “U” Space, or are you looking for a vertical solution? Spectrum Power Management Systems offers 0U, 1U, and 2U products to support a variety of power distribution needs. We know how important rack space is and, therefore, strive to provide the most power possible in the smallest package. You can get up to 24 outlets in a compact, 33” 0U design! What are your future expectations? Obviously, it is important to first consider what your present power needs are. However, it is also very important to think about what you may require in the future. Power requirements in data centers continue to grow. Therefore, it is best to choose scalable and flexible solutions that are able to grow with the increasing network demands. Although you might not currently need a high power output, you might consider selecting a power strip with a slightly higher output to prepare for your growing needs. The same applies to voltage. Also keep in mind that you should never load a PDU to its maximum to help prevent possible overload. Also ensure that the “upstream” breakers are sufficiently rated to match the total maximum rating of the PDU. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 4 Considerations for the Use of 3 Phase Wiring Why are data centers compelled to use 3 Phase at the cabinet? Minimizing the number of wires under the elevated flooring is a good practice to improve air flow and provide a great deal more clarity to the electricians. A significantly reduced amount of wiring can be attained when using a 3 Phase Wye (5 Wire System) versus the supposed equivalent of Single Phase wiring. An electrician would actually be required to run 3 individual 3 conductor cables compared to a single 5 conductor 3 Phase Wye cable. Benefits of 3 Phase Wiring: • • Reduced material and installation (Labor) costs Balanced loads on a single circuit versus the use of 3 individual single phase circuits 3 Phase WYE (Y) A 3 Phase-Wye connected system consists of three hot lines, or phases, commonly referred to as X, Y, Z, a neutral, and a ground wire for a total of five wires in a power distribution cable. In North America the most common 3 Phase-Y voltages are either 120/208 VAC or 277/480 VAC, while internationally the most common 3 Phase voltage is 230/400 VAC. The lower voltage in each case is the country’s standard utilization voltage and is measured Lineto-Neutral, while the higher voltage is measured Line-to-Line. The Line-to-Line voltage is always 1.732 times higher than the Line-to-Neutral voltage in a Wye configured 3 Phase system. The line current supplied to the load is also the same as the phase current. It is important to note that when all three “Hot” phases of the system are loaded equally, the net current draw in the neutral line is zero! Red (Black) Y iL iP 3 L1 VP Black (Brown) X VL-L iL = iP VL-L = √3 VP White (Blue) N Blue (Grey) Z Green/Yellow G 3 Phase Delta (∆) A 3 Phase-Delta connected system consists of three hot lines, commonly referred to as X,Y, Z, and a ground wire for a total of four wires in a power distribution cable. In North America the most common 3 Phase-∆ voltages are either 208VAC or 240VAC, while internationally the most common 3 Phase voltage is 230 VAC. These phase voltages are measured Line-to-Line and are typically the country’s standard utilization voltage. Since there is no neutral line in a Delta-connected system, there is no Line-to-Neutral voltage! However, the line current in a Delta-connected system is 1.732 times the phase current supplied to the load(s). Proper care must be taken to correctly size cables in a Delta system because the line currents are much higher than the load (or phase) currents. Delta systems typically have lower line voltages but higher line currents than Wye-connected systems. Red iP iL = √3 iP VP 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 5 Y iL VL-L = VP VL-L Black X Blue Z Green/Yellow G ey Features & Benefits of SpecPower® Power Strips Flexibility Our portfolio of AC Power Strips & Specialty Solutions includes a variety of power inputs and outputs which allows you to mix and match components to accommodate most power distribution needs. Both NEMA and IEC receptacles and plugs are utilized. Monitored and unmonitored versions are available. Unmonitored devices are a reliable cost-efficient means to basic power distribution. Monitored units, in addition to the same features as the standard devices, provide an excellent visual indication of the load in a data center cabinet. Both styles are perfect for a variety of environments. Power Whether you require basic power output or high power output, we have a solution to fit your needs! Output power capabilities range from 2.40 to 22.08 KVA. For easy product selection, we have categorized our products into four groups based on power output: Basic Power, Intermediate Power, High Power, and Enforcer Power. Basic Power Strips provide up to 5 kW of power. Intermediate Power Strips range from 5 - 10 kW. Enforcer Power Strips provide up to 25 kW of power. Compact 0U, 1U, and 2U Designs We know how important your rack space is. That’s why we strive to produce high-quality power solutions in a compact size, leaving valuable “U” space for other network-critical devices. This also allows the power sockets to be placed close to the equipment being powered, reducing the nuisance of cable clutter. The dominant focus of this brochure is towards 0U products, but 1U and 2U products are manufactured and supported. Please see available products in this brochure or call Spectrum Power Management Systems at 814-272-SPMS. Circuit Protection All circuit protected power devices use UL 489-listed circuit breakers to manually control on/off operation for groups of receptacles. No fuses are used which allows the unit to return to service quickly and easily. For easy power-on indication, each circuit breaker features an LED power-on indicator, and each circuit is clearly labeled to help simplify load balancing. Standard Warranty Under normal use and specified operation conditions, all power units are warranted from the day of delivery for a period of one year. During this period, if the product should fail, contact the factory or point of purchase for an RMA and instructions on the return procedure. Additionally, RMA instructions and support can be found online at www.specpower.com 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 6 Power Categories Basic Power Provides reliable power for up to (14) 1U servers, (9) 2U servers, or a combination of each. Intermediate Power Allows for dependable power distribution to up to (28) 1U servers or (18) 2U servers. These units are also capable of providing power to up to 2 blade server chassis. High Power Enables consistent power supply to low, medium, and high-density devices. Enforcer Power Supports up to 6 high-density, power-hungry blade servers or other high-powered devices. ow Many Servers Can a Single Unit Support 1U Server with 2U Server with Blade Server with Average Power Draw Average Power Draw Average Power Draw of 0.35 kW of 0.55 kW of 4 kW Basic Power (0-5 kW) Intermediate Power (5-10 kW) High Power (10-15 kW) Enforcer Power (15-25 kW) 0-5 6-14 4-9 0-1 2.40 6 4 N/A 4.80 13 8 1 5-10 14-28 9-18 1-2 6.90 19 12 1 9.36 26 17 2 10-15 28-42 18-27 2-3 11.04 31 20 2 14.00 40 25 3 15-25 42-71 27-45 3-6 22.08 63 40 5 24.00 68 43 6 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 7 33” NEMA Configurations - Single Phase L5-20P Power Cord Connector W 72A-120BFLBN-00 G Standard AC Power Strips X L5-20P Power Cord Connector W X 100-127 VAC Line Current 20A Max. (16A Derated) Output Power 2.40 KVA - (Basic Power) Output Connector 12 x NEMA 5-20R Input Protection 20A 1 Pole Circuit Breaker Panel Indicators Power-on, LED Voltage Input 100-127 VAC Voltage Output 100-127 VAC Line Current 20A Max. (16A Derated) Output Power 2.40 KVA - (Basic Power) Output Connector 22 x NEMA 5-20R Input Protection 20A 1 Pole Circuit Breaker Panel Indicators Power-on, LED 72A-120BULBN-00 IEC C20 Power Inlet Connector N IEC C20 Power Inlet Connector L 100-127 VAC Voltage Output 72A-120BFVBN-00 G L Voltage Input Voltage Input 100-127 VAC Voltage Output 100-127 VAC Line Current 20A Max. (16A Derated) Output Power 2.40 KVA - (Basic Power) Output Connector 12 x NEMA 5-20R Input Protection 20A 1 Pole Circuit Breaker Panel Indicators Power-on, LED 72A-120BUVBN-00 N Voltage Input 100-127 VAC Voltage Output 100-127 VAC Line Current 20A Max. (16A Derated) Output Power 2.40 KVA - (Basic Power) Output Connector 22 x NEMA 5-20R Input Protection 20A 1 Pole Circuit Breaker Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 8 33” NEMA Configurations - Single Phase L5-30P Power Cord Connector W G L5-30P Power Cord Connector Voltage Input 100-127 VAC Voltage Output 100-127 VAC Line Current 30A Max. (24A Derated) Output Power 3.60 KVA - (Basic Power) Output Connector 2 x 6 NEMA 5-20R Input Protection (2) 15A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-130BHTBN-00 W G L6-20P Power Cord Connector Voltage Input 100-127 VAC Voltage Output 100-127 VAC Line Current 30A Max. (24A Derated) Output Power 3.60 KVA - (Basic Power) Output Connector 2 x 10 NEMA 5-20R Input Protection (2) 15A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-120BKLEN-00 X G Y L6-20P Power Cord Connector Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 20A Max. (16A Derated) Output Power 4.60 KVA - (Basic Power) Output Connector 12 x IEC C13 Input Protection 20A 2 Pole Circuit Breaker Panel Indicators Power-on, LED 72A-120BKXEN-00 X G Y Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 20A Max. (16A Derated) Output Power 4.60 KVA - (Basic Power) Output Connector 24 x IEC C13 Input Protection 20A 2 Pole Circuit Breaker Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 9 Standard AC Power Strips 72A-130BHLBN-00 33” NEMA Configurations - Single Phase Dual IEC C20 Power Inlet Connectors Standard AC Power Strips L 72A-240BULBN-00 N Dual IEC C20 Power Inlet Connectors L Voltage Input 100-127 VAC Voltage Output 100-127 VAC Inlet Current 2 x 20A Max. Output Power 4.80 KVA - (Basic Power) Output Connector 2 x 6 NEMA 5-20R Input Protection (2) 20A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-240BUTBN-00 N L6-30P Power Cord Connector Voltage Input 100-127 VAC Voltage Output 100-127 VAC Inlet Current 2 x 20A Max. Output Power 4.80 KVA - (Basic Power) Output Connector 2 x 10 NEMA 5-20R Input Protection (2) 20A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-130BMLEN-00 X G Y Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x 6 IEC C13 Input Protection (2) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 10 33” NEMA Configurations - Single Phase L6-30P Power Cord Connector X G Y Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x (5-IEC C13, 1-IEC C19) Input Protection (2) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-130BMTGN-00 L6-30P Power Cord Connector X G Y L6-30P Power Cord Connector Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x (9-IEC C13, 1-IEC C19) Input Protection (2) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-130BMXEN-00 X G Y Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x 12 IEC C13 Input Protection (2) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 11 Standard AC Power Strips 72A-130BMLGN-00 33” NEMA Configurations - Three Phase Standard AC Power Strips L21-20P Power Cord Connector 72A-160BPRBN-00 Voltage Input 208 VAC +10%/-15%, 3 Phase WYE Voltage Output 120 VAC Nominal Line Current 20A Max. (16A Derated) Output Power 7.20 KVA - (Intermediate Power) Output Connector 3 x 6 NEMA 5-20R Input Protection (3) 20A 1 Pole Circuit Breakers Panel Indicators Power-on, LED L15-30P Power Cord Connector 72A-178BWOGN-00 Voltage Input 208 VAC +10%/-15%, 3 Phase, Delta Voltage Output 208 VAC Nominal L-L Line Current 26A Max. (24A Derated) Output Power 9.36 KVA - (Intermediate Power) Output Connector 3 x (4-IEC C13, 1-IEC C19) Input Protection (3) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED L15-30P Power Cord Connector 72A-178BWLFN-00 Voltage Input 208 VAC +10%/-15%, 3 Phase, Delta Voltage Output 208 VAC Nominal L-L Line Current 26A Max. (24A Derated) Output Power 9.36 KVA - (Intermediate Power) Output Connector 3 x 4 IEC C19 Input Protection (3) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 12 33” NEMA Configurations - Three Phase L15-30P Power Cord Connector 72A-178BWREN-00 Voltage Input 208 VAC +10%/-15%, 3 Phase, Delta Voltage Output 208 VAC Nominal L-L Line Current 26A Max. (24A Derated) Output Power 9.36 KVA - (Intermediate Power) L21-30P Power Cord Connector Input Protection (3) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-190BQRBN-00 Voltage Input 208V +10%/-15%, 3 Phase, WYE Voltage Output 120 V Line Current 30A Max. (24A Derated) Output Power 10.80 KVA - (High Power) Output Connector 18 x NEMA 5-20R Input Protection (2) 15A 1 Pole Circuit Breakers/Phase Panel Indicators Power-on, LED L21-30P Power Cord Connector 72A-190BQREN-00 Voltage Input 208V +10%/-15%, 3 Phase, WYE Voltage Output 120 V Line Current 30A Max. (24A Derated) Output Power 10.80 KVA - (High Power) Output Connector 18 x IEC C13 Input Protection (2) 15A 1 Pole Circuit Breakers/Phase Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 13 Standard AC Power Strips Output Connector 3 x 6 IEC C13 33” Global Configurations - Single Phase IEC 60309, 16A Power Cord Connector Standard AC Power Strips L 72A-116BXLEN-00 L IEC 60309, 16A Power Cord Connector L Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 16A Max. Output Power 3.68 KVA - (Basic Power) Output Connector 12 x IEC C13 Input Protection 16A 2 Pole Circuit Breaker Panel Indicators Power-on, LED 72A-116BXXEN-00 L Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 16A Max. Output Power 3.68 KVA - (Basic Power) Output Connector 24 x IEC C13 Input Protection 16A 2 Pole Circuit Breaker Panel Indicators Power-on, LED IEC 60309, 32A Power Cord Connector L 72A-132BATGN-00 L Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x (9-IEC C13, 1-IEC C19) Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 14 33” Global Configurations - Single Phase IEC 60309, 32A Power Cord Connector L L Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x 12 IEC C13 Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED IEC 60309, 32A Power Cord Connector 72A-132BALGN-00 Voltage Input L L Voltage Output 200-250 VAC Line Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x (5-IEC C13, 1-IEC C19) Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED IEC 60309, 32A Power Cord Connector L 200-250 VAC 72A-132BALEN-00 L Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x 6 IEC C13 Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 15 Standard AC Power Strips 72A-132BAXEN-00 33” Global Configurations - Three Phase IEC 60309, 16A Power Cord Connector L3 Standard AC Power Strips N 72A-148BXREN-00 L2 L1 IEC 60309, 16A Power Cord Connector L3 N Voltage Input 3øY, 400 VAC Voltage Output 230 VAC Line Current 16A Max. Output Power 11.04 KVA - (High Power) Output Connector 3 x 6 IEC C13 Input Protection (3) 16A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-148BXLFN-00 Voltage Input L2 L1 Voltage Output 230 VAC Line Current 16A Max. Output Power 11.04 KVA - (High Power) Output Connector 3 x 4 IEC C19 Input Protection (3) 16A 1 Pole Circuit Breakers Panel Indicators Power-on, LED IEC 60309, 16A Power Cord Connector L3 N 72A-148BXOGN-00 L2 L1 Voltage Input 3øY, 400 VAC Voltage Output 230 VAC Line Current 16A Max. Output Power 11.04 KVA - (High Power) Output Connector 3 x (4-IEC C13, 1-IEC C19) Input Protection (3) 16A 1 Pole Circuit Breakers Panel Indicators Power-on, LED IEC 60309, 32A Power Cord Connector L3 N 3øY, 400 VAC 72A-196BAREN-00 L2 L1 Voltage Input 3øY, 400 VAC Voltage Output 230 VAC Line Current 32A Max. Output Power 22.08 KVA - (Enforcer Power) Output Connector 18 x IEC C13 Input Protection (6) 16A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 16 33” Cordless Configurations - NEMA or Global Voltage Capability * NEMA Models are also capable of 120-125 VAC output with proper cordage. IEC C20 Power Inlet Connector 72A-120BULEN-00 72A-116BULEN-00 N (NEMA) Voltage Input 200-250 VAC* (Global) 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 20A Max. 16A Max. Output Power 4.60 KVA - (Basic Power) 3.68 KVA - (Basic Power) Output Connector 12 x IEC C13 12 x IEC C13 Input Protection 20A 2 Pole Circuit Breaker 16A 2 Pole Circuit Breaker Panel Indicators Power-on, LED Power-on, LED IEC C20 Power Inlet Connector L 72A-120BUXEN-00 72A-116BUXEN-00 N (NEMA) (Global) Voltage Input 200-250 VAC* 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 20A Max. 16A Max. Output Power 4.60 KVA - (Basic Power) 3.68 KVA - (Basic Power) Output Connector 24 x IEC C13 24 x IEC C13 Input Protection 20A 2 Pole Circuit Breaker 16A 2 Pole Circuit Breaker Panel Indicators Power-on, LED Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 17 Standard AC Power Strips L 33” Cordless Configurations - NEMA or Global Voltages Capable * NEMA Models are also capable of 120-125 VAC output with proper cordage. Dual IEC C20 Power Inlet Connectors 72A-240BULEN-00 72A-232BULEN-00 (NEMA) Standard AC Power Strips L Voltage Input N (Global) 200-250 VAC* 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 2 x 20A Max. 2 x 16A Max. Output Power 9.20 KVA (Intermediate Power) 7.36 KVA (Intermediate Power) Output Connector 2 x 6 IEC C13 2 x 6 IEC C13 Input Protection (2) 20A 2 Pole Circuit Breakers (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED Power-on, LED 72A-240BULGN-00 72A-232BULGN-00 Dual IEC C20 Power Inlet Connectors L N (NEMA) Voltage Input (Global) 200-250 VAC* 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 2 x 20A Max. 2 x 16A Max. Output Power 9.20 KVA (Intermediate Power) 7.36 KVA (Intermediate Power) Output Connector 2 x (5-IEC C13, 1-IEC C19) 2 x (5-IEC C13, 1-IEC C19) Input Protection (2) 20A 2 Pole Circuit Breakers (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 18 33” Cordless Configurations - NEMA or Global Voltages Capable Dual IEC C20 Power Inlet Connectors L N 72A-240BUXEN-00 72A-232BUXEN-00 (NEMA) (Global) Voltage Input 200-250 VAC* 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 2 x 20A Max. 2 x 16A Max. Output Power 9.20 KVA (Intermediate Power) 7.36 KVA (Intermediate Power) Output Connector 2 x 12 IEC C13 2 x 12 IEC C13 Input Protection (2) 20A 2 Pole Circuit Breakers (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED Power-on, LED Dual IEC C20 Power Inlet Connectors 72A-240BUTGN-00 72A-232BUTGN-00 (NEMA) L N (Global) Voltage Input 200-250 VAC* 200-250 VAC Voltage Output 200-250 VAC* 200-250 VAC Inlet Current 2 x 20A Max. 2 x 16A Max. Output Power 9.20 KVA (Intermediate Power) 7.36 KVA (Intermediate Power) Output Connector 2 x (9-IEC C13, 1-IEC C19) 2 x (9-IEC C13, 1-IEC C19) Input Protection (2) 20A 2 Pole Circuit Breakers (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED Power-on, LED 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 19 Standard AC Power Strips * NEMA Models are also capable of 120-125 VAC output with proper cordage. 66” NEMA Configurations - Voltage Input 120 VAC Voltage Output 120 VAC Line Current 30A Max. (24A Derated) Output Power 3.60 KVA - (Basic Power) Output Connector 2 x 12 NEMA 5-20R Input Protection (2) 15A 1 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-130BMXGN-10 72A-130BMXGN-10 72A-130BHXBN-10 Standard AC Power Strips 72A-130BHXBN-10 Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x (9-IEC C13, 3-IEC C19) Input Protection (2) 15A 1 Pole Circuit Breakers Panel Indicators Power-on, LED L5-30P Power Cord Connector W G L6-30P Power Cord Connector X G Y 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 20 66” NEMA Configurations - Voltage Input 200-250 VAC Voltage Output 200-250 VAC Line Current 30A Max. (24A Derated) Output Power 6.90 KVA - (Intermediate Power) Output Connector 2 x 12 IEC C13 Input Protection (2) 15A 2 Pole Circuit Breakers Panel Indicators Power-on, LED Voltage Input 3øY, 208 VAC Voltage Output 120/208 VAC Line Current 30A Max. (24A Derated) Output Power 10.80 KVA - (Intermediate Power) Output Connector 3 x (6-IEC C13, 2-NEMA 5-20R) Input Protection (3) 20A 1 Pole Circuit Breakers (3) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED X G Y L21-30P Power Cord Connector 72A-190BQXGN-10 72A-130BMXEN-10 72A-190BQXGN-10 L6-30P Power Cord Connector 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 21 Standard AC Power Strips 72A-130BMXEN-10 66” Global Configurations - 200-250 VAC Voltage Output 200-250 VAC Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x (9-IEC C13, 3-IEC C19) Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED 72A-132BAXEN-10 Voltage Input 200-250 VAC Voltage Output 200-250 VAC Current 32A Max. Output Power 7.36 KVA - (Intermediate Power) Output Connector 2 x 12 IEC C13 Input Protection (2) 16A 2 Pole Circuit Breakers Panel Indicators Power-on, LED IEC 60309, 32A Power Cord Connector L3 N L3 N 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 22 L2 L1 IEC 60309, 32A Power Cord Connector 72A-132BAXEN-10 72A-132BAXGN-10 Standard AC Power Strips 72A-132BAXGN-10 Voltage Input L2 L1 Mechanical Specifications 66” Model Dimension 33” Model Dimension 1.730 4) (4.39 .00 66 .64) 7 (16 .00 33 .82 (83 3 (8 .25 .25 5) Front View: 69.00 (175.26) 36.00 (91.44) 68.00 (172.72) 35.00 (88.90) Bracket View: One pair of standard brackets are shipped with each Standard AC Power Strip. The brackets are adjustable to allow for mounting on the back or either side. Additional mounting brackets are available for purchase. For bracket options, please refer to pages 26-27. Note: Brackets are shipped loose with hardware 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 23 Standard AC Power Strips Dimension for Both Models 14” Satellite Power Strips IEC C20 Power Inlet Connector L N Perfect for “wall warts”! 72A-120NUJBN-00 100-127 VAC 100-127 VAC / 200-250 VAC* 72A-120NUGBN-00 100-127 VAC Voltage Output 100-127 VAC 100-127 VAC / 200-250 VAC* 100-127 VAC Inlet Current 20A Max. 16A / 20A* Max. 20A Max. Input Protection Requires External Branch CB Requires External Branch CB Requires External Branch CB Output Power 2.40 KVA - (Basic Power) 3.68 / 2.40* KVA - (Basic Power) 2.40 KVA - (Basic Power) Output Connector 10 x NEMA 5-20R 12 x IEC 60320 C13 7 x NEMA 5-20R IEC 60320 C13 Rating 15A Max. (Individual) 10A / 15A* Max. (Individual) 15A Max. (Individual) * North America Rating Mechanical Specifications Top View: 14.00 (35.56) Front View: 15.50 (39.37) Side View: 1.50 (3.81) 1.73 (4.39) Standard AC Power Strips Voltage Input 72A-120NULEN-00 For information on horizontal mounting brackets, please refer to page 26. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 24 Cable Trays for Power Strips 33” Cable Tray - 72-1021-293 Enhance your installation by adding this cable management tray to any 33” Standard AC Power Strip. Help organize your cabinet by securing cords via cable ties to any of the holes on this tray. It’s a fast and convenient way to ensure organization in your cabinet. 0 5.0 .70) 2 (1 1.48 ) (3.76 Front View: 33.0 7 (84.0 9 2) Side View: 1.50 (3.81) 3.875 (9.84) 6.00 (15.24) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 25 Power Strip Accessories For cable management trays in different lengths and styles, please contact a Sales Associate at 814-272-SPMS. Optional Mounting Brackets From this: Kit 72-1021-287 0U to 1U Adapter This bracket allows for easy horizontal mounting of the Satellite Strips. This option gives you the added flexibility of changing your 0U strip into a 1U solution. The kit includes two adapter brackets and hardware. Power Strip Accessories To this: Kit 72-1021-292 Gravity Clip This solution allows for easier installation of your vertical mount power strip. The kit includes one gravity clip, one standard bracket, and hardware. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 26 Optional Mounting Brackets Kit 72-1021-291 Stud Mount Plate Kit 72-1021-288 Button Adapter The Button Adapter enables existing rack enclosures to accommodate power strips with button hardware. The kit includes two adaptor brackets, two buttons, and hardware. Kit 72-1021-290 This option includes two adaptor brackets and hardware. No buttons are included. Kit 72-1021-289 Button Mount This tooless mounting option is great for rack enclosures that allow button mounting. The kit includes two buttons and hardware. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 27 Power Strip Accessories This solution provides an alternative method to mount power strips in various rack enclosures. The installer is able to rotate the stud plate to the most favorable position. The kit includes two stud plates and hardware. Power Cords Type INPUT INPUT Power Strip Accessories INPUT INPUT INPUT INPUT Part Number Plug Type Outlet Type 10’ 15A/125V, 14 AWG 3 SJT PC10-515P-C13 5-15P C13 5-15P C19 10’ 15A/125V, 14 AWG 3 SJT PC10-515P-C19 10’ 20A/125V, 12 AWG 3 SJT PC10-520P-C19 5-20P C19 L5-20P C19 6-20P C19 10’ 20A/125V, 12 AWG 3 SJT PC10-L520P-C19 10’ 20A/250V, 12 AWG 3 SJT PC10-620P-C19 10’ 20A/250V, 12 AWG 3 SJT PC10-L620P-C19 L6-20P INPUT C19 10’ 16A/250V, 12 AWG 3 SJT PC10-IEC16-C19 IEC60309 16A PATCH C19 1.5’ 15A/250V, 14 AWG 3 SJT PP1.5-C14-C13 C14 PATCH PATCH PATCH PATCH C13 3’ 15A/250V, 14 AWG 3 SJT PP3-C14-C13 C14 C13 C14 C13 C14 C13 PP5-C14-C13 PP10-C14-C13 PP1.5-C1413PK8 C13 C14 PATCH Description PP1.5-C1413PK16 C13 C14 5’ 15A/250V, 14 AWG 3 SJT 10’ 15A/250V, 14 AWG 3 SJT (8 PACK) 1.5’ 15A/250V, 14 AWG 3 SJT (16 PACK) 1.5’ 15A/250V, 14 AWG 3 SJT 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 28 Part Number PATCH PP3-C1413PK8 Plug Type Outlet Type C14 PATCH C13 PP3-C1413PK16 C14 PATCH C13 3’ 15A/250V, 14 AWG 3 SJT PP3-C14-C19 C19 5’ 15A/250V, 14 AWG 3 SJT PP5-C14-C19 C14 PATCH C19 10’ 15A/250V, 14 AWG 3 SJT PP10-C14-C19 C14 PATCH C19 5’ 15A/250V, 14 AWG 3 SJT PP5-C20-C13 C20 PATCH C13 3’ 20A/250V, 12 AWG 3 SJT PP3-C20-C19 C20 PATCH C19 5’ 20A/250V, 12 AWG 3 SJT PP5-C20-C19 C20 PATCH C19 10’ 20A/250V, 12 AWG 3 SJT PP10-C20-C19 C20 PATCH C19 PP3-C2019PK8 C20 PATCH C19 PP3-C2019PK16 C20 PATCH C19 PP5-C2019PK8 C20 PATCH (16 PACK) 3’ 15A/250V, 14 AWG 3 SJT C19 C14 PATCH (8 PACK) 3’ 15A/250V, 14 AWG 3 SJT 1.5’ 15A/250V, 14 AWG 3 SJT PP1.5-C14-C19 C14 PATCH Description C19 PP5-C2019PK16 C20 C19 (8 PACK) 3’ 20A/250V, 12 AWG 3 SJT (16 PACK) 3’ 20A/250V, 12 AWG 3 SJT (8 PACK) 5’ 20A/250V, 12 AWG 3 SJT (16 PACK) 5’ 20A/250V, 12 AWG 3 SJT 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 29 Power Strip Accessories Type IEC 60309, 32A Global Power Cord Connectors 72A-264BAHEN-02 72A-260BMHEN-02 L6-30P NEMA Power Cord Connectors X L3 N L2 L1 G Y Specialty AC Power Solutions Dual Input, 208/230 VAC 8 IEC C13 Outlets With Circuit Protection When properly installed into a standard EIA 19” Rack, this power strip provides for the reliable power distribution of up to 14.72 Kilowatts of power via eight IEC C13 outlets available for power up to 230 VAC auxiliary appliances. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment The Global unit features two IEC 309 - 32A input connectors, and each input is protected with (2) 16A UL-489 listed circuit breakers. The NEMA unit features two L6-30P connectors, and each input is protected with (2) 15A UL-489 listed circuit breakers. These circuit breakers are designed to prevent accidental actuation to the OFF position while in service, but can be turned OFF manually for equipment maintenance or repair. Electrical & Mechanical Specifications Input and Output Global (72A-264BAHEN-02) NEMA (72A-260BMHEN-02) Power Input Dual, Single Phase, AC Dual, Single Phase, AC Voltage Range 230 VAC +5%/-15% 208 VAC +5%/-15% Frequency 50-60 Hz 50-60 Hz Line Current 2 x 32 Amps 2 x 30 Amps (2 x 24 Amps Derated) Input Protection (2) 16A 2 Pole Circuit Breakers/Input (2) 15A 2 Pole Circuit Breakers/Input Power Output 14.72 KVA - (High Power) 12.48 KVA - (High Power) Output Receptacles 8 x IEC C13 4 x 2 IEC C13 Panel Indicators LED, Power-on LED, Power-on Physical and Environmental Global (72A-264BAHEN-02) NEMA (72A-260BMHEN-02) Size (Overall) 29.13”W x 1.73”H x 4.50”D Temp. Range 0°C to 50°C Weight ≈ 16 lbs. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 30 Mechanical Specifications Top View: 4.50 (11.43) Global (72A-264BAHEN-02) 31.13 (79.07) Front View: 29.13 (73.99) Back View: 1.73 (4.39) Global (72A-264BAHEN-02) 1.73 (4.39) NEMA (72A-260BMHEN-02) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 31 Specialty AC Power Solutions NEMA (72A-260BMHEN-02) IEC 60309, 32A Global Power Cord Connectors 72A-264BAXEN-02 72A-260BMXEN-02 L6-30P NEMA Power Cord Connectors X L3 N L2 L1 Dual Input, 208/230 VAC 24 IEC C13 Outlets With Circuit Protection Specialty AC Power Solutions G Y When properly installed into a standard EIA 19” Rack, this power strip provides for the reliable power distribution of up to 14.72 Kilowatts of power via 24 IEC C13 outlets available for power up to 230 VAC auxiliary appliances. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment The Global unit features two IEC 309 - 32A input connectors, and each input is protected with (2) 16A UL-489 listed circuit breakers. The NEMA unit features two L6-30P connectors, and each input is protected with (2) 15A UL-489 listed circuit breakers. These circuit breakers are designed to prevent accidental actuation to the OFF position while in service, but can be turned OFF manually for equipment maintenance or repair. Electrical & Mechanical Specifications Input and Output Global (72A-264BAXEN-02) NEMA (72A-260BMXEN-02) Power Input Dual, Single Phase, AC Dual, Single Phase, AC Voltage Range 230 VAC +5%/-15% 208 VAC +5%/-15% Frequency 50-60 Hz 50-60 Hz Line Current 2 x 32 Amps 2 x 30 Amps (2 x 24 Amps Derated) Input Protection (2) 16A 2 Pole Circuit Breakers/Input (2) 15A 2 Pole Circuit Breakers/Input Power Output 14.72 KVA - (High Power) 12.48 KVA - (High Power) Output Receptacles 24 x IEC C13 8 x 3 IEC C13 Panel Indicators LED, Power-on LED, Power-on Physical and Environmental Global (72A-264BAXEN-02) NEMA (72A-260BMXEN-02) Size (Overall) 55.50”W x 1.73”H x 4.50”D Temp. Range 0°C to 50°C Weight ≈ 17 lbs. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 32 Front View: 58.324 (148.14) Top View: 56.324 (143.06) Side View: 1.720 (4.37) 2.981 (7.57) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 33 Specialty AC Power Solutions Mechanical Specifications 7200-A-39S1 IEC C20 Power Inlet Connector Specialty AC Power Solutions 240VAC, 16A, 8 IEC C13 Outlets With Surge Protection L When properly installed into a standard EIA 19” rack, this power strip provides for the reliable power distribution of up to 3.84 Kilowatts of power via eight IEC C13 outlets available for power up to 200 – 240 VAC auxiliary appliances. The Power Strip’s AC inlet is filtered to reduce emissions in Information Technology (IT) applications and provides at least 30db of common mode noise reduction and even greater differential noise reduction between the frequency ranges of 1 to 10 Megahertz. N Applications Financial Centers Data Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment In addition, the Power Strip contains thermally protected Transient Voltage Suppression (TVS) networks, which clamp common mode and differential mode voltage transients with up to 170 Joules of energy content. The Power Strip is also equipped with LED indicator lamps that show a “green” status if the main power input is present, and if the TVS networks are ready and functional. The builtin UL 489 circuit breaker is designed to prevent accidental actuation to the OFF position while in service, but it can be turned OFF manually for equipment maintenance or repair. Electrical & Mechanical Specifications Input Specifications Output Power Input Single Phase, AC Power OutputΨ Voltage Range 240 VAC+10%/-15% Frequency Currentµ 47-63 Hz. Output Receptacle PE Ground# Input Protection∆ Power Dissipationε Panel Indicatorsβ TVSτ 16 Amps Physical and Environmental 16A, Circuit Breaker 10W nom. @ 240 VAC LED, Main & TVS 170 Joules Specifications 3.84 KVA - (Basic Power) 8x-IEC 60320/C13 1/4”-20 threaded Stud Specifications Size (Overall)λ 19.0”W x1.72”H x6.50”D Temp. Range 0°C to 55°C Weight ≈ 5.7 lb (≈ 2.6 kg) # µ ∆ Ψ ε λ β Denotes Protective Earth Ground Denotes a maximum continuous input current of 16A at 250Vac. Leakage current < 3.5mA @ 250Vac. The circuit breaker is UL 489 Listed, features a flat rocker front surface with “Accidental Off” feature. Output power is the combined power of the eight outlets, which averages 2 amps/outlet at 240Vac. Power dissipation is the combination of heat losses due to wiring, input filter leakage, and LED indicators. Overall size includes the width of the mounting flanges. The PDU cabinet is sized for EIA 19” rack installation. LED’s are turned-off when TVS networks are disconnected from the circuitry because of overheating caused by abnormal transient voltage conditions. τ TVS network is thermally protected, and will absorb the specified energy of both common mode and differential mode transients for 2 msec. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 34 EMI/RFI Filtering • • • Common Mode – Line to Ground Differential Mode – Line to Line High Frequency Ground Isolation Frequency (Mhz) Common Mode Differential Mode .15 .45 1 2 5 10 30 15 22 28 35 42 48 55 13 8 40 60 72 68 58 Mechanical Specifications 16 Amp Breaker Green LED 100,000 Hour Life, X3 Back View: 17.00 (43.18) Ground Stud 1/4-20 X .50” IEC 320-C13 Receptacles (8X) IEC 320-C20 Inlet Plug (1X) 17.19 (43.66) 17.00 (43.18) 6.50 (16.51) 2.10 (5.33) Bottom View: Note: Remove screw prior to Hi Pot. Install after performing Hi Pot. Front View: 1.720 (4.37) Side View: 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 35 Specialty AC Power Solutions Typical Insertion Loss (dB) 7200-A-39-3 L5-30P Power Cord Connector W Specialty AC Power Solutions 120VAC, 30A, 16 NEMA 5-20R Outlets With Surge Protection G When properly installed into a standard EIA 19” Rack, this power strip provides for the reliable power distribution of up to 3.60 Kilowatts of power via sixteen NEMA 5-20R outlets available for power up to 120 VAC auxiliary appliances. The power strip’s AC inlet is filtered to reduce emissions in Information Technology (IT) applications and provides at least 30db of common mode noise reduction, and even greater differential noise reduction between the frequency ranges of 1 to 10 Megahertz. Applications Industrial ATE Cabinets Financial Centers Data Centers Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment In addition, the power strip contains thermally protected Transient Voltage Suppression (TVS) networks, which clamp common mode and differential mode voltage transients with up to 170 Joules of energy content. The Power Strip is also equipped with LED indicator lamps that show a “green” status if the main power input is present, and if the TVS networks are ready and functional. The builtin UL 489 circuit breaker is designed to prevent accidental actuation to the OFF position while in service, but it can be turned OFF manually for equipment maintenance or repair. Electrical & Mechanical Specifications Input Specifications Power Input Single Phase, AC Voltage Range 120 VAC+10%/-15% Frequency 47-63 Hz. Currentµ 30 Amps Input Protection∆ Specifications Output Power OutputΨ Output Receptacle PE Ground# 3.60 KVA - (Basic Power) 8 x 2 NEMA 5-20R 1/4”-20 threaded Stud Physical and Environmental 8 x 15A Circuit Breakers Specifications Power Dissipationε 10W nom. @ 120 VAC Size (Overall)λ 19.0”W x 3.50”H x 6.50”D Panel Indicatorsβ TVSτ LED, Main & TVS Temp. Range 0°C to 50°C 170 Joules Weight ≈ 11 lb (≈ 5 kg) # µ ∆ Ψ ε λ β Denotes Protective Earth Ground Denotes a maximum input line current of 30A at 120Vac (circuit derating = 24 Amps). Leakage current < 3.5mA @ 120Vac. The circuit breaker is UL 489 Listed, features a flat rocker front surface with “Accidental Off” feature. Output power is the combined power of the sixteen outlets, which approximates 1.9 Amps/outlet at 120Vac. Power dissipation is the combination of heat losses due to wiring, input filter leakage, and LED indicators. Overall size includes the width of the mounting flanges. The PDU cabinet is sized for EIA 19” rack installation. LED’s are turned-off when TVS networks are disconnected from the circuitry because of overheating caused by abnormal transient voltage conditions. τ TVS network is thermally protected, and will absorb the specified energy of both common mode and differential mode transients for 2 msec. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 36 Mechanical Specifications 17.00 (43.18) 18.316 (46.52) 19.00 (48.26) Back View: 8x2 NEMA 5-20R Side View: 6.00 (15.24) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 37 3.47 (8.81) 3.00 (7.62) 1.749 (4.44) Front View: Specialty AC Power Solutions 6.00 (15.24) Top View: 72RA2A8BWFFN-00 72RA296BXFFN-00 IEC 60309, 32A/Phase L15-30P Global Power NEMA Power Cord Connectors Cord Connectors L3 N L2 L1 Specialty AC Power Solutions Dual Input, 3 Phase 6 IEC C19 Outlets With Surge Protection When properly installed into a standard EIA 19” Rack, this dual input 3 Phase supplied power strip provides for up to 22 Kilowatts of reliable power from six IEC C19 outlets. It supports auxiliary appliances operation from 200 - 240 VAC. The six individual outlets, one per phase, are each protected with a 16 Amp UL489 listed circuit breaker. These circuit breakers are designed to prevent accidental actuation to the OFF position while in service, but can be turned OFF manually for equipment maintenance or repair. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Great for use with 20A blade servers and switches. The Power Strip provides a simple AC Power Distribution solution for the new WS-CAC-8700W-E (8700 Watt AC input power supply) of the advanced Catalyst 6509E Switch, and is also an ideal solution for all 20 Amp 200-240 VAC appliances. Electrical & Mechanical Specifications Input and Output Global (72RA296BXFFN-00) NEMA (72RA2A8BWFFN-00) # ∆ Ψ λ * Input Configuration Dual 3 Phase, Y Dual 3 Phase, ∆ Voltage Input 400 VAC+10%/-15% 208 VAC+10%/-15% Voltage Output 230 VAC 208 VAC Line Current* 16A Max./Input 30A Max./Input Output Power Ψ PE Ground# 22.08 KVA - (Enforcer Power) 17.29 KVA - (Enforcer Power) (2) 1/4”-20 Studs (2) 1/4”-20 Studs Output Connector Input Protection∆ (6) IEC 320 C19 (6) IEC 320 C19 16A 1 Pole Circuit Breaker/Outlet 16A 2 Pole Circuit Breaker/Outlet Panel Indicators Power-on, LED Power-on, LED Physical and Environmental Global (72RA296BXFFN-00) NEMA (72RA2A8BWFFN-00) Size (Overall)λ 19.0”W x1.72”H x6.50”D 19.0”W x1.72”H x6.50”D Temp. Range -5°C to 70°C -5°C to 70°C Weight 20 lbs 20 lbs Denotes Protective Earth Ground The circuit breaker is UL 489 Listed, features a flat rocker front surface with “Accidental Off” feature. Output power is the combined power of six outlets at nominal output voltage (at derated current). Overall size includes the width of the mounting flanges. The PDU cabinet is sized for EIA 19” rack installation. Derated current is 80% of maximum line current for NEMA version PDU. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 38 Mechanical Specifications Top View: 19.00 (48.26) Front View: 1.72 LED Power-on Indicator (6X) Back View: IEC C19 (6X) Side View: 6.50 (16.51) Global (72RA296BXFFN-00) NEMA (72RA2A8BWFFN-00) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 39 Specialty AC Power Solutions 6.50 (16.51) 17.00 (43.18) 72A-120BUHEM-71 IEC C20 Power Inlet Connector L Specialty AC Power Solutions 240VAC, 20A, 8 IEC C13 Outlets With Circuit Protection and Current Meter This Spectrum Power Management Systems power strip is specially designed for reliable power distribution up to 4.60 Kilowatts of power via eight IEC C13 outlets to 200240 VAC appliances. To avoid the possibility of system faults, the unit features a UL 489-listed circuit breaker and LCD current metering. The advanced power strip allows the user to monitor the total load drawn at the PDU source. This enables the user to quickly identify current draw on an individual appliance basis. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment Rapid Deployment Rack The unit also features an IEC C20 power inlet connector for an economical solution to power distribution needs. The 72A-120BUHEM-71 is a simple solution for all 20 Amp 200-240 VAC VAC appliances. Electrical & Mechanical Specifications Input and Output Voltage Input 200 - 240 VAC Voltage Output 200 - 240 VAC Inlet Current 20A maximum Output Power 4.60 KVA - (Basic Power) Output Connector (8) IEC C13 Input Protection 20A Single Pole Circuit Breaker Panel Indicators Power-on, LED Physical and Environmental Size (Overall) 29.13”W x 1.69”H x 2.97”D Temp. Range 0°C to 40°C Weight 7 lbs. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 40 N Front View: 20A Circuit Breaker with Finger Guard 1.69 (4.29) Bulk Current Meter 29.134 (73.99) Back View: 31.496 (80.00) 30.512 (77.50) Side View: 2.972 (7.55) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 41 Specialty AC Power Solutions Mechanical Specifications 72A-196BAREMS01 72A-190BQREMS01 IEC 60309, 32A Global Power Cord Connector L3 N L21-30P NEMA Power Cord Connector L2 L1 Specialty AC Power Solutions 18 IEC C13 Outlets 3 Phase Power Monitoring and Distribution Unit This Spectrum Power Management Systems PDU is an AC power distribution unit designed to distribute power for up to eighteen (18) AC loads. The PDU distributes 3 Phase power to six individual, over current protected, output banks. The unit has multiple alarm capabilities and includes an audible alarm circuit. Voltage and current are monitored and displayed locally on a liquid crystal display and remotely through a LAN connection. The LAN module consists of integrated hardware and a network agent software program. These components provide the ability to configure, control, and monitor aspects of multiple units using a standard Web browser. The network interface can operate using the Web, Telnet, and SNMP. Operation/ control is accomplished by use of six 16A breaker actuators. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment This product complies with FCC, CE, TUV, UL60950-1 and IEC60950 requirements. Electrical & Mechanical Specifications Input and Output Global (72A-196BAREMS01) NEMA (72A-190BQREMS01) Input Configuration 3 Phase-Y, AC 3 Phase-∆, AC Voltage Input 3 ∅ 400/230VAC ±10% 3 ∅ 208/208VAC ±10% Voltage Output 200/230 VAC 208 VAC Phase Current 72A maximum, combined 41.6A maximum, combined Output Power 16.56 KVA - (High Power) 8.65 KVA - (Intermediate Power) (18) IEC C13 Output Connector Input Protection (6) 16A 2 Pole Circuit Breakers Panel Indicators LED Physical and Environmental Global (72A-196BAREMS01) NEMA (72A-190BQREMS01) Size (Overall) 55.5”W x1.75”H x5.2”D Temp. Range 0°C to 55°C Weight 32.5 lbs 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 42 Specialty AC Power Solutions Mechanical Specifications 2.50 (6.35) Top View: Front View: 55.50 (140.97) Current Meter LAN Connector Side View: 1.75 (4.44) 3.75 (9.53) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 43 Specialty AC Power Solutions Remote/Local Power Management System The AC SMARTStart® is a multifunctional AC power distribution unit designed to control eight AC loads and monitor vital parameters. This product is available in 15 Amp, 16 Amp, and 20 Amp total load capacity models. In addition, we offer output configurations that use screw clamp terminal blocks, in lieu of IEC or NEMA connectors, for industrial applications. All models have the ability to power-on or power-off any or all loads in any sequence over a wide range of time intervals. The PDU automatically sequences each output. This significantly reduces the total inrush current and limits the possibility of equipment damage due to the combined turn-on transient of several loads. The sequence order and delay is user defined at setup. A circuit breaker at the AC input provides overall protection. To prevent the circuit breaker from tripping during power up, the PDU features a power-on current limit. The AC SMARTStart® is also capable of monitoring input line voltage and total load current, as well as line frequency. Operation/control is accomplished either manually, using controls on the front panel of the unit, or remotely, using a computing device that utilizes EIA RS-232 and RS485/422 communications such as a laptop computer, desktop computer, or other personal electronic device. Two user programmable external contacts can be configured to alert the user of under-voltage, over-current, or over-temperature conditions using the dry contact closure. These contacts allow remote operation and control from Web browser or Telnet interface. Features • • • • • • • • • Power control capability to groups of outlets Remote operation and control capabilities via Telnet or Web interface Local operation and control capabilities by means of front panel push-button switch and backlit LED status indicator Monitors input line voltage, total load current, line frequency, and remote external temperature (with optional temperature sensor) Two isolated contact inputs can be used with alarm sensors, security sensors, limit switches, and/or remote stop Emergency Power Off (EPO) configuration also possible May be used as a master PDU with several slaves linked via RS-485/422 or RS-232 Includes optional front or center mounting brackets Complies to FCC, CE, UL, and TÜV requirements 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 44 Web/Telnet/SNMP Option: Enhanced Web-based device set-up and control management • Auto Ping feature to test and optionally power cycle a connected host • Email alerts for up to three designated recipients • Optional sensors can be incorporated and included in alarm email alerts with user defined messages • SNMP MIB for standards-based monitoring and control of the power distribution unit and its associated operating features Main Screen Outlet Control with Group Management Capability Alert Threshold Screen 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 45 Specialty AC Power Solutions • Initial Set Up Screen Electrical & Mechanical Specifications Input and Output Global 16 Amps Nominal Input Voltage 95 - 137 VAC or 200 - 208 VAC Input Frequency Specialty AC Power Solutions NEMA 20 Amps 200 - 230 VAC 47 -63 Hz 47 -63 Hz 16A max. per breaker 20A max. per breaker Power Entry Connector IEC C20 Inlet IEC C20 Inlet or NEMA 5-20P on 10’ cord Outlet Connectors 8 x IEC C13 8 x NEMA 5-20R 1.92 or 3.26 KVA (Basic Power) 4.30 KVA (Basic Power) 95 - 137 VAC - 16A 1 Pole Circuit Breaker 20A 2 Pole Circuit Breaker Input Current Output Power Input Protection 200 - 208 VAC - 16A 2 Pole Circuit Breaker Panel Indicators LED LED Physical and Environmental Global NEMA 16 Amps 20 Amps Size (Overall) 17.19”W x 1.75”H x 8.00”D Weight ≈ 11 lbs. Operating Temp. ≈ 11 lbs. 0 - 45°C (32 - 113°F) Operating Humidity 0 - 95% (non-condensing) Operating Elevation 0 - 10,000 ft. (0 - 3000 m) Communications: • • • • • RS-232: Front panel DB-9F or DB-9M connector RS-485/422 rear panel RJ-11 Telnet with web interface (when ordered with LAN module) SNMP Other options available upon request Accessory (Optional): • Temperature Sensor 72-1021-189 (Hookup wire not supplied) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 46 Part Number Configuration D 20 12 S N T Amperage 20 for NEMA 16 for Global AC SMARTStart® Voltage Design A = AC D = NEMA E = Global L = NEMA 5-20P fixed cord-set Emergency Power Off (EPO) option - add E to the end of the part number Communications Options N = Telnet Voltage 12 = 120 VAC for NEMA 24 = 230 VAC for Global Inputs S = 1 input, 1x8 configuration E Transient Protection Options T = Circuit protection (includes TMOV) Ordering Information (15 Amp also available) Part Number Voltage Input Input Connection Output Connection Configuration Communication 7608AD2012S 120VAC/47-63Hz IEC C20 NEMA 5-20R Single Input Serial RS232 7608AL2012S 120VAC/47-63Hz NEMA 5-20P on 10’ cord NEMA 5-20R Single Input Serial RS232 7608AE1624S 230VAC/47-63Hz IEC C20 IEC C13 Single Input Serial RS232 7608AD2012SN 120VAC/47-63Hz IEC C20 NEMA 5-20R Single Input Serial RS232 & Web/Telnet 7608AL2012SN 120VAC/47-63Hz NEMA 5-20P on 10’ cord NEMA 5-20R Single Input Serial RS232 & Web/Telnet 7608AE1624SN 230VAC/47-63Hz IEC C20 IEC C13 Single Input Serial RS232 & Web/Telnet 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 47 Specialty AC Power Solutions A 7608 Mechanical Specifications 8.00 (20.32) 17.188 (43.66) Front View: Start Power Button Breaker Off/On Output Indicator LEDs Communications Switch Ready Light Remote & Local Lights PDA RS-232C DCE Computer RS-232C DTE Web/Telnet RJ-45 Back View: 2x8-pin ‘Quick Disconnect’ RJ-11/EIA RS-485 Connection AC Power Entry 1.745 (4.44) Specialty AC Power Solutions Top View: See Ordering Information for Outlet Configuration 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 48 7200-A-49 The AC Power Master is a 19 inch rack mountable Power Distribution Unit (PDU) that distributes 3 Phase and Single Phase AC Voltage to several output circuits. The PDU provides overload current protection via a primary circuit breaker and seven branch circuit breakers. The 7200-A-49 also provides Emergency Power Off (EPO) capability locally by means of an EPO switch and remotely through an external interface. The inherent benefit of this product is that is minimizes inrush current by sequencing the individual outlets a predefined delay. Design features: • • • • • • • • • • • • Three Phase and Single Phase over current protection Power indication for each branch circuit Power sequencing Safety protection via EPO interface, shorting plugs, and local EPO button/switch 14VAC EPO output Elapsed time indicator Optional RS-422/485 remote control and status Common mode and differential mode filtering Function and mode switches (for remote, local, on, off, and start features) Rugged construction Reliable for transport in mobile training centers Additional EMI Filter option The front panel of the PDU contains the mode and function switches. The mode switch is used to set the PDU into remote or local operation. Once implemented, the “REMOTE” position can be used with the RS422/485 communication port to control output as well as provide status feedback. The “LOCAL” position is used to operate the PDU in conjunction with the mode switch as follows. The “OFF” position of the function switch is used for local or remote operation and disables output relays, not allowing power to the rear panel under any circumstances. The “ON” position of the function switch is used for local or remote operation to enable output relays to be energized. The “START” position of the function switch is used for local operation only and will initiate the default output start sequence for the PDU. Remote Capabilities: • • • • • • • Power up sequence Power off all outputs Power on individual outputs Change delay/output sequence Output status feedback Configurable for a unique HEX address Adjustable baud rate 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 49 Specialty AC Power Solutions 208 VAC, 3 Phase NEMA L21-30R, NEMA L5-20R, and NEMA 5-15R Outlets with Output Protection Electrical & Mechanical Specifications Input/Output Specialty AC Power Solutions Input Configuration AC 3 Phase, Y Voltage Input 208 VAC Voltage Output 208 VAC (3-Phase NEMA L21-30R), 120 VAC (NEMA L5-20R & NEMA 5-20R) Current 70 Amps/Phase Frequency 60 Hz. Output Power 30A (3-Phase NEMA L21-30R), 20A (NEMA L5-20R), 15A (NEMA 5-20R) PE Ground Stud 1/4” - 20 Threaded Stud Output Connector 3-Phase NEMA L21-30R, (3) NEMA L5-20R, (8) NEMA 5-20R Input Connector IEC 4 Pole/5 Wire Input Protection 3-Pole, 250 VAC, 30A Breaker Output Protection 3-Pole, 250 VAC, 30A Breaker, (6) 1-Pole, 250 VAC, 20A Breaker Panel Indicators Multiple LEDs Physical and Environmental Size (Overall) 19”W x 7”H x 28.75”D Temp. Range 0˚ to 45˚ (A wider temperature range is possible.) Weight 41 lbs. Wiring/Schematic Diagram ELAPSED TIME INDICATOR CB5 +- 30A LOAD 4 +208VAC, 30A 1 2 3 4 5 120VAC, 15A 1 2 3 120VAC, 20A 1 2 3 120VAC, 15A 1 2 3 120VAC, 20A 1 2 3 120VAC, 20A 1 2 3 120VAC, 15A 1 2 3 120VAC, 15A 1 2 3 120VAC, 15A 1 2 3 120VAC, 15A 1 2 3 120VAC, 15A 1 2 3 120VAC, 15A 1 2 3 LOAD 6 INPUT 3 PHASE 70A BREAKER CB7 F1 P1 MAIN CONTACTOR INPUT EMI FILTER 1 2 3 4 5 20A +- GND CB6 20A CB3 20A CB4 20 CB2 20A LOAD 5 -+ LOAD 2 -+ POWER SUPPLY LOAD 3 -+ EPO INTERFACE EPO LOGIC BOARD LOAD 1 -+ EPO SWITCH MODE SWITCH CPU CB8 20A FUNCTIONSWITCH REMOTE INTERFACE LOAD 7 -+ 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 50 Mechanical Specifications 19.00 (48.26) Back View: 17.00 (43.18) 3 X NEMA L5-20R 3-Phase NEMA L21-30R 8 X NEMA 5-20R Side View: 7.00 (17.78) 28.75 (73.025) We are a total solutions team able to provide a multitude of solutions suited to most environments and hardware utilization. We offer full service metal fabrication, PCB layout, machining centers, and environmental and electrical testing. Contact our team for applications we can assist you with. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 51 Specialty AC Power Solutions Top/Front View: Specialty AC Power Solutions Safety Instructions • Before installation read these instructions carefully and completely. These installation instructions cannot cover every possible installation, operation or maintenance situation. Further information can be obtained from the product data sheets, which can be obtained from Spectrum Power Management Systems. • Circuits should be sized according to local and national codes. • If you are using a 200/250 VAC power source in North America, the circuit must be protected by a two-pole circuit breaker or single pole breaker if properly configured for International wiring. • The source AC outlet must be within 6 feet (1.8 meters) of the system and should be easily accessible. • This Power Distribution Unit (PDU) is constructed and approved in accordance with the safety requirements of IEC/EN60950, and UL 508, and FCC emission standards. • Before any installation, maintenance or modification work, ensure that the power source is switched off, and properly secured to remain off. Touching any live components or improper handling of this PDU can result in death, severe personal injury or substantial damage to property. Safe operation is dependent on proper storage, handling, installation and operation. • Compliance with the relevant national regulations in the USA, Europe, or other countries must be ensured. Before operation is started, the following conditions must be observed: ■ Connections to mains supply in compliance with national regulations (NEC, NEMA, VDE0100 and EN50178). ■ Use of stranded wires; all strands must be fastened in the terminal blocks (Potential danger of contact with the enclosure). ■ Power supply and mains cables must be sufficiently fused. ■ Degree of protection I to IEC536. The non-fused protective earth connection must be connected to the Field Ground Terminal. ■ All output wires must be rated for the output current of the PDU and must be connected with the correct polarity. Never work on the PDU if power is applied! Risk of electric shock, which can cause death, severe personal injury or substantial property damage. Installation 1. This PDU is designed for Military, Commercial, or Industrial indoor systems horizontal mounting into a standard EIA 19” equipment rack. It is attached to the vertical rails with 10-32 screws, and tightened to 30 in-lb (3.4 N•m).  WARNING WARNING! Failure to properly ground this PDU by not tightening the rack screw fasteners or fully insert the PEM into the equipment rack can create a hazardous condition to the installer and to the equipment. 2. Attach up to twelve (12) equipment loads to the 3-Phase NEMA L21-30R, NEMA L5-20R, and NEMA 5-15R receptacles of the PDU. Total combined load must be less that that specified in page 50. 3. Attach the power source to the power strip’s IEC 4 Pole/5 Wire input receptacle.  WARNING WARNING! Prior to connecting input power cable, ensure that the circuit breaker is turned off and that the input power to the PDU is turned off. 4. VERIFY – prior to applying power to the PDU, ensure the input circuit breaker is turned-off. Apply power to the PDU. 5. VERIFY – the LED indicator lamps on the PDU illuminate. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 52 SMART Start® & Power Monitoring Unit The DC SMARTStart® is a -48, +12, or +24/+28 VDC power distribution and circuit protection unit designed to reliably cycle power to devices with DC power supplies. The DC SMARTStart® has specialized electronic switchable solid state breakers to provide a true remote power cycling capability. To minimize the downtime, this PDU family has a breaker auto reset function. The on-board computer will pole the tripped channel position to determine whether there is indeed a fault, such as a short circuit. If this condition is determined to be non catastrophic, the breaker is reset. The client is able to disable this feature if desired. The unit also features integral circuitry to provide LVD and OVD protection automatically. LAN TCP/IP socket or telnet session. The DC SMARTStart® is the ideal DC power distribution and circuit protection solution for Unmanned Vehicles, Command Post Platforms, Competitive Local Exchange Carriers (CLECs), Incumbent Local Exchange Carriers (ILECs), XDSL applications, CATV enterprises, and blade servers. The DC SMARTStart® PDU will permit the network operator the ability to power cycle all 12 solid state breakers as well as the 2 ROCB mains breakers. Refer to the Ordering Information table for respective trip currents. The SMARTStart® PDU features a visual basic (VB) Interface to program the power up/ down sequence and power up/down delays for each channel, along with the LVD and OVD thresholds. There are numerous remote operated circuit breaker values available (see table) that provide primary current protection to the PDU and down stream equipment controlled by the PDU. The ROCBs are UL listed primary circuit protection to the six outputs on side A and B. Our newest high current, direct feed version provides easy power cycling to 48VDC powered routers/ switches, DSLAMS and other enterprise-related equipment via remote activated circuit breakers rated up to 100 Amps. The DC SMARTStart® PDU is capable of monitoring line voltage, circuit breaker status and internal temperature to provide the required power and circuit protection to connected equipment. Operational control is performed either manually by front panel push buttons or remotely through either an RS-232 serial console port 10/100 BASE-T or 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 53 Specialty DC Power Solutions Remote/Local Power Management System DC SMARTStart® Features • • Specialty DC Power Solutions • • • • • • On board 6 month event log. Flash upgradeable in the field without disruption of power to loads. Independent programmable power on and off sequencing delays to reduce/manage the level of inrush current transients. Remote control capability by means of LAN TCP/IP socket, Telnet connection or RS-232 serial console port. Front Panel push buttons for local output control. Output status is displayed through individual tricolored LEDs for each output. LVD (low voltage disconnect) & OVD (over voltage disconnect) using user defined values. Reverse polarity protection. Solid state electronic circuit breaker technology. • • • • • • • SNMP agent on board. Auto reset to nuisance trip breakers (up to 3 times prior to alarm threshold alert of breaker trip - user configurable). Monitors line voltage. circuit breaker status, and internal temperature of the PDU. The ROCBs may be used to switch power on or off to each output side (A or B) either locally or remotely. Optional design to provide high ampacity output available to capacity of 100A on each A & B output. See ordering information. Three form C relay contacts available for alarm notification. Programmable at factory. UL listed and NEBS Level 3 certified. Complies to FCC and CE requirements. Remote Monitoring Unit Features • • • Flash upgradeable in the field without disruption of power to loads. Remote control capability by means of LAN TCP/IP socket, Telnet connection or RS-232 serial console port. SNMP agent on board. • Available in 4, 6, 8, 10, or 12 channels. Visual Basic (VB) GUI Interface: • • • • Multiple PDU interface control in active screen. Easy to use interface for either serial or TCP/IP communication. Enhanced web-based device set-up and control management. Standards-based monitoring and control of the power distribution unit and its associated operating features. Communications: • • • LAN/Telnet: Front panel RJ-45 connector. TCP/IP protocol. RS-232: Serial front panel 9 position female D-sub connector. Easy to use Visual Basic (VB) interface for either serial or TCP/IP communication. Multiple PDU interface control in active screen. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 54 DC SMARTStart® Ordering Information Electrical & Mechanical Specifications Input Voltage -48, +12, or +24/+28 VDC Size (Overall) 17.25”W x 1.75”H x 8.00”D (43.8cm W x 4.44cm H x 20.4cm D) Weight 13.3 lbs. (6.1 kg) Operating Temp. Operating Humidity 0 - 95% (non-condensing) Operating Elevation 0 - 10,000 ft. (0 - 3000 m) Output Part Input Input Number Voltage Current VDC Distributed Direct A&B Individual Factory Set Input Output Output Trip Connection Configuration Steady Current State Load (Nominal) (Max) 7832S30 -48 30 Amps 5 Amps 5.9 Amps 6 A, 6 B 7832S3012 +12 30 Amps 5 Amps 5.9 Amps 6 A, 6 B 7832S3024 +24 30 Amps 5 Amps 5.9 Amps 6 A, 6 B Non-rotational terminal block 5/8” centers, 1/420 threads 7832S60 -48 60 Amps 10 Amps 11.2 Amps 7832S6012 +12 60 Amps 10 Amps 11.2 Amps 7832S6024 +24 60 Amps 10 Amps 11.2 Amps 50 Amps 50 Amps 60 Amps 1 A, 1B 80 Amps 80 Amps 100 Amps 1 A, 1B 100 Amps 100 Amps 120 Amps 1 A, 1B 7832RB050 7832RB080 -48 7832RB100 6 A, 6 B 6 A, 6 B 6 A, 6 B Solid State Breaker Ratings Trip Curve Steady State Amps Factory Set Trip Current Slow (51-110 msec) Medium (11-50 msec) Fast (<10 msec) 3 3.45    5 5.75    7.5 8.625    10 11.5    15 17.25    20 23 N/A   If you cannot find the solution you are looking for, custom solutions are available. Please use the tables below to configure your unit. Then, contact a sales representative at 814-272-SPMS. A configuration tool is also available on our website for your added convenience. -48 VDC MAX. LOAD SIDE A SIDE B SIDE A SIDE B 100 1 2 4 5 6 1 2 3 4 5 6 5 6 100 +12 OR +24/+28 VDC SIDE A MAX. LOAD SIDE A SIDE B 80 3 1 2 3 4 5 6 SIDE B 1 2 3 4 80 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 55 Specialty DC Power Solutions 0 - 45°C (32 - 113°F) DC SMARTStart®Mechanical Specifications Direct A&B Outputs: Outlet Connectors: Non-rotational terminal block 5/8” (.625”) centers, 1/4-20 threads Specialty DC Power Solutions Front View: Remote Operated Circuit Breaker (ROCB) (2 PLCS) LAN Connector (10/100 Base-T) EIA RS-232 Connector Output Terminal Block 2x2, 1/4-20 Stud (2 PLCS) Back View: Input Terminal Block 2x2, 1/4-20 Stud (2 PLCS) Alarm Connector Connectors: Anderson Power Products 1327 Distributed Outputs: Outlet Powerpole series-rated 45A Front View: LAN Connector (10/100 Base-T) Circuit Breaker B Local EIA RS 232 Connector Circuit Breaker A Back View: B Output (6 PLCS) A Output (6 PLCS) DC Supply A Input DC Supply B Input 10 Pin Phoenix Alarm Output 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 56 DC SMARTStart® Mechanical Specifications Front View: 17.25 (43.8) 1.75 (4.44) Back View: The DC SMARTStart® is shipped with one 72-1021-070 installation kit. Included in the kit are: (12) 4-40 Captive Panel Screws (12) Captive Screw Nuts (12) Red Housings (12) Blue Housings (24) 45 Amp Contacts (Load should not exceed 25A, due to mating contact inside the PDU.) (12) Output Connector Set Spacers (Red) (4) 2-Hole Ring Terminals Additional kits are available for purchase and are sold separately. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 57 Specialty DC Power Solutions 8.00 (20.4) Top View: Power Monitoring Unit Mechanical Specifications 0 10.0 ) 4 (25. Front View: 17.25 (43.8) EIA RS-232 Connector LAN Connector (10/100 Base-T) Back View: 1.75 (4.44) Specialty DC Power Solutions Top View: 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 58 Spectrum Power Management Systems’ DC SMARTStart® and power monitoring set have been employed together or individually in various applications in many industries. These devices provide reliable remote-managed power to the Military, Medical, Industrial, and Telco industries, as well as data centers throughout the world. It is used to power several devices including blades, servers, switches, communications equipment, unmanned vehicles, simulators, and Command Post Platforms. The DC SMARTStart® has been employed in the following applications: - Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Defense ATE Equipment Portable Communications Equipment Rapid Deployment Racks / Transit Cases Telecom Messaging Systems Wireless Messaging Platforms Remote Sensors Data Centers Powered by DC Voltage Remote Cameras 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 59 Specialty DC Power Solutions DC SMARTStart® & Power Monitoring Unit Applications 7400-DS79 Specialty DC Power Solutions Reliable Over-Current Protection with Isolated Circuits for Increased Safety Spectrum Power Management Systems is a leading manufacturer of OEM solutions for AC and DC power distribution and power strip solutions. SPMS designs and develops some of the industry’s most reliable products for power distribution and circuit protection. Spectrum Power Management Systems’ 7400-DS79 Breaker Interface Panel offers a reliable solution for power distribution and circuit protection. Power and return lines for all panel circuits are isolated in the “off” state by magnetic circuit protectors, offering superior protection and safety. This panel operates at -48VDC with a maximum current of 70 Amps per side. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Terabit Switches Wireless Messaging Platforms The unit is designed with a removeable front panel to provide access to 12 pluggable circuit breakers. A bi-color LED over each input terminal block provides verification of proper polarity termination at power hook-up. Red indicates a reverse polarity condition. Electrical & Mechanical Specifications Input and Output Physical and Environmental Specifications Specifications Voltage Operating -48VDC nominal Size (Overall) 17.0”W x 3.470”H x 12.06”D Voltage Range -36VDC to -72VDC Temp. Range 0°C to 50°C (32°F to 122°F) Current Rating 70 Amps per Side Max. Lug Size Panduit #LCD4-14AH-L For #4AWG External Power Feed Wiring to PDU Temp. Range 0°C to 65°C (32°F to 149°F) Operating Humidity 0 - 95% Operating Elevation: 0 - 10,000 ft (0 - 3000 m) Weight ≈ 25 lb (≈ 11.34 kg) Power Output -48VDC PE Ground Panduit #PV6-10R-E For #6AWG External Ground Wire or Braid to the PDU (Without Forced Air Cooling) (With Forced Air Cooling) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 60 • Circuit breaker protection for your valuable DC system. • Power and return lines are isolated for all circuits in the “off” state by magnetic circuit protectors. • A bi-color LED over each input terminal block assures correct polarity during hook up. Red indicates reverse polarity. • Positive polarized latching connector system provides for quick field installation. • Dual Polarity Diode O-Ring Circuitry adds isolation and increases reliability. O-Ring circuitry is protected by PCB mounted, externally resettable, 20 Amp magnetic circuit protectors. • With the removal of the front access panel, the individual circuit breakers can be easily serviced to minimize down time. • PDU circuit protection configuration is easily modified by the user but not to exceed the maximum current rating of the PDU per output. • PDU circuitry utilizes bus bar and PCB “Heavy Trace” technology for enhanced power dissipation. SPMS Breaker Interface Panels Provide a Safer System! Isolated power and return lines in the “off” state protect the user from unexpected exposure to live power. Live “On” Status Protected (Tripped) “Off” Status 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 61 Specialty DC Power Solutions Features Specialty DC Power Solutions User-Removable Front Panel Circuit Breakers Each unit comes pre-installed with two fixed 70 Amp A & B input mains circuit breakers and four non-removable O-Ring Diode breakers (two 10A and two 5A breakers). The unit does not come populated with the 12 user-removable front panel circuit breakers. These are sold separately to ensure each unit is populated to accommodate the user’s requirements. Each position must not exceed 30 Amps max. Also, the total of the pluggable breakers must not exceed the value of the A & B input mains breakers. Front Pluggable Breaker Part Number 5 Amp 22-0425-5420 10 Amp 22-0425-5410 15 Amp 22-0425-9990 20 Amp 22-0425-9980 25 Amp 22-0425-9970 30 Amp 22-0425-5780 Front Panel Fastener (4 Plcs) Indicator Lamp (2 Plcs) 70A Fixed Main Input Circuit Breaker (2 Plcs) Removable Front Panel Removable Circuit Breaker (12 Plcs) (Not Included - Ordered Separately) Back 10A Fixed Circuit Breakers 2 Position Tyco 770024-1 Housing Connector Rated to 31 Amps (16 Plcs) (Mating Connector is a Tyco 770017-1) Indicator Lamp (2 Plcs) Ground Screw (2 Plcs) 5A Fixed Circuit Breakers 4 Position Molex Alarm Connector Resettable Push Button (Dry Contact) Breaker (2 Plcs) (Default is open to Alarm) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 62 Mechanical Specifications Front View: 19.00 (48.26) 17.00 (43.18) 3.47 (8.81) Back View: 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 63 Specialty DC Power Solutions 12.00 (30.48) Top View: 7400-DS93 Specialty DC Power Solutions Reliable Over-Current Protection with Isolated Circuits for Increased Safety Spectrum Power Management Systems is a leading manufacturer of OEM solutions for AC and DC power distribution and power strip solutions. SPMS designs and develops some of the industry’s most reliable products for power distribution and circuit protection. Spectrum Power Management Systems’ 7400DS93 Breaker Interface Panel offers a reliable solution for protecting your system from over-current damage. Power and return lines for all panel circuits are isolated in the “off” state by magnetic circuit protectors, offering superior protection and safety. This panel operates at -48VDC with a maximum current of 90 Amps per side. Applications Data Centers Financial Centers Industrial ATE Cabinets Scientific Instrumentation Cabinets Communications Base Stations Network Operating Centers Terabit Switches Wireless Messaging Platforms The unit is designed with a removeable front panel to provide access to 6 pluggable circuit breakers. A bi-color LED over each input terminal block provides verification of proper polarity termination at power hook-up. Red indicates a reverse polarity condition. Electrical & Mechanical Specifications Input and Output Physical and Environmental Specifications Specifications Voltage Operating -48VDC nominal (Reverse Polarity Protected) Size (Overall) 17.0”W x 1.725”H x 12.00”D Voltage Range -36VDC to -72VDC Temp. Range (Without Forced Air Cooling) 0°C to 50°C (32°F to 122°F) Current Rating 90 Amps per Side Max. Temp. Range 0°C to 65°C (32°F to 149°F) Lug Size Panduit #LCD4-14AH-L For #4AWG External Power Feed Wiring to PDU Operating Humidity 0 - 95% Operating Elevation 0 - 10,000 ft (0 - 3000 m) Weight ≈ 12 lb (≈ 5.45 kg) Power Output -48VDC PE Ground Panduit #PV6-10R-E For #6AWG External Ground Wire or Braid to the PDU (With Forced Air Cooling) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 64 • Circuit breaker protection for your valuable DC system. • Power and return lines are isolated for all circuits in the “off” state by magnetic circuit protectors. • A bi-color LED over each input terminal block assures correct polarity during hook up. Red indicates reverse polarity. • Positive polarized latching connector system provides for quick field installation. • With the removal of the front access panel, the individual circuit breakers can easily be serviced to minimize down time. • PDU circuit protection configuration is easily modified by the user but not to exceed the maximum current rating of the PDU per output. • PDU circuitry utilizes bus bar and PCB “Heavy Trace” technology for enhanced power dissipation. SPMS Breaker Interface Panels Provide a Safer System! Isolated power and return lines in the “off” state protect the user from unexpected exposure to live power. Live “On” Status Protected (Tripped) “Off” Status 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 65 Specialty DC Power Solutions Features Specialty DC Power Solutions User-Removable Front Panel Circuit Breakers Each unit comes pre-installed with two fixed 90 Amp A & B input mains circuit breakers. The unit does not come populated with the 6 userremovable front panel circuit breakers. These are sold separately to ensure each unit is populated to accommodate the user’s requirements. Each position must not exceed 30 Amps Max. Also, the total of the pluggable breakers must not exceed the value of the A & B input mains breakers. Pluggable Breaker Part Number 5 Amp 22-0425-5420 10 Amp 22-0425-5410 15 Amp 22-0425-9990 20 Amp 22-0425-9980 25 Amp 22-0425-9970 30 Amp 22-0425-5780 Front Front Panel Fastener (2 Plcs) Indicator Lamp (2 Plcs) 90A Fixed Push Button Main Circuit Breaker (2 Plcs) Removable Circuit Breaker (6 Plcs) (Not Included - Ordered Separately) (Image shown with safety caps) Removable Front Panel Back 4 Position Molex Alarm Connector (Dry Contact) (Default is open to Alarm) Indicator Lamp (2 Plcs) 2 Position Tyco 770024-1 Housing Connector Rated to 31 Amps (16 Plcs) (Mating Connector is a Tyco 770017-1) 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 66 Mechanical Specifications Front View: 17.00 (43.18) 19.00 (48.26) 1.725 (4.38) Back View: 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 67 Specialty DC Power Solutions 12.00 (30.48) Top View: Specialty DC Power Solutions Data Acquisition & Power Monitoring • • • • • • • Consists of a high level monitoring computer Six dual current sensing modules Two independent AC voltage channels (input 120VAC) Two independent 10 AMP AC current channels Six independent 35 Amp 24 VDC current channels Four independent 60 Amp 24 VDC current channels Ten 24 VDC inputs for on/off state For more information on Data Acquisition Modules and Power Monitoring, please contact a Sales Representative at 814-272-SPMS or [email protected]. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 68 Quality Assurance Spectrum Power Management Systems tests all power strips and power distribution systems for conformance to all applicable functional standards. In order to provide the most accurate and specific testing procedures, our engineering staff has developed custom and automated test equipment that is positioned at critical points in our manufacturing operation. We administer our test procedures not only for prototypes, but for each and every power product we manufacture. This focus on quality and reliability is part of the commitment we make to our customers. Dependent on application, SPMS can tailor additional tests to provide verification for unique application environments. The compliance tests performed are described below. Ground Bond Test Circuit Breaker Trip Curve Checks for proper continuity through the chassis ground circuit by applying high current and measuring the ground resistance via kelvin connection. Voltage Drop Test Checks for excessive resistance of the wire paths in the PDU from the individual pins on the input plug to each of the outlet receptacles. This test is performed at full load. It also verifies the proper termination of each power output receptacle. High Pot Test Checks for electrical isolation from a hot circuit at high voltage to ground. Overload Test Checks the circuit breaker reaction (trip curve) by applying a high load to the power strip. 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 69 Request for Customer Specific Solution Company Name Phone Contact Name Title E-mail Quantity Required Target Price First Unit Required by Date Unit Brand/Model # of Existing Solution Project Time Line Power Input Quantity Physical Configuration Input AMPS Plug Type Input VOLTS Dimensional Limits Mounting Orientation 5-15P 15 125 Length Horizontal L5-15P 15 125 Width Vertical 5-20P 20 125 Height L5-20P 20 125 6-20P 20 250 L6-20P 20 250 L21-20P 20 120/208 WYE 5-30P 30 125 L5-30P 30 125 6-30P 30 250 L6-30P 30 250 L15-30P 30 250 Delta L21-30P 30 120/208 WYE IEC C20 Inlet (No Cord) 20 125 or 250 IEC Pin & Sleeve 2 Pole/3Wire 30/32 250/230 IEC Pin & Sleeve 2 Pole/4 Wire 60/63 Local Current Monitoring Remote Current Monitoring No No Yes - (Volts, Amps, Watts, Power Factor) Yes - Circuit Level Circuit Breakers Surge Suppression Remote Switching No No (Required by NEC in some units) No Yes Yes Yes IEC C14 Inlet Agency Testing & Compliance 250/230 15’ Cord No Plug UL® Listed UR-UL® Recognized FCC Part 15 Class A CE® None Required Other-Please Specify Term. Block Custom Solution Additional Information Power Outlets Quantity Receptacle Type Input AMPS Input VOLTS 5-15R 5-20R 6-15R 6-20R IEC C13 IEC C19 Custom Solution 1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 70 We Are Your Total Power Solutions Provider! Spectrum Power Management Systems is one of the few partners fully versed in both AC and DC applications. We offer a family of power management products designed to give you several different approaches to distributing and sequencing the AC or DC power to your infrastructure equipment.  AC Power Solutions        Single Phase Power Strips 3 Phase Power Strips Monitored Power Strips SMARTStart® Switched PDUs Power Sequencers Power Entry Panels with Circuit Protection Specialty Hi-Rel Power Management Systems  DC Power Solutions       Circuit Breaker Interface Panels -48VDC / “+24 to +28”VDC Fuse Interface Panels -48VDC / “+24 to +28”VDC Data Acquisition & Monitoring Modules Specialty Hi-Rel Power Management Systems SMARTStart® -48VDC / “+24 to +28” VDC PDUs Custom Designs - AC or DC Our applications specialists will visit your facility to meet with your product development team. These specialists, along with our in-house design team, provide you with the diverse background necessary to develop high-quality power distribution solutions. Our expertise in both AC and DC applications enables us to create power distribution panels with intelligent monitoring and remote management with the ability to remote sequence your applications. We will share with you our complete product offering and capabilities to help meet budgeting program requirements. Ability to monitor and control power and environmental conditions for infrastructure equipment.  Custom OEM designs using SMARTStart® technology.  Vertical integration including qualification testing, sheet metal fabrication, software development, and hardware integration.  1900 West College Avenue, State College, PA 16801 • 814-272-SPMS • [email protected] 71 “A Spectrum of High Performance Solutions” Power Management Systems Spectrum Power Management Systems 1900 West College Avenue State College, Pennsylvania 16801 Phone: 814-272-SPMS Fax: 814-272-2702 www.specpower.com [email protected] Single Phase AC Power Strips Three Phase AC Power Strips AC Power Strips with Meter Display AC Power Sequencers AC Power Entry Panels with Circuit Protection Customer Specific AC Power Outlet Strips AC SMARTStart® Switched PDU DC SMARTStart® -48VDC / “+24 to +28”VDC DC Circuit Breaker/Fuse Panels -48VDC / “+24 to +28”VDC AC or DC Specialty Hi-Rel Power Management Systems www.specpower.com EMI Filters & Components Investor Relations Corporate Headquarters 8031 Avonia Road Fairview, Pennsylvania 16415 Phone: 814-474-2207 Fax: 814-474-2208 Ferrite Beads & Inductors Surface Mount Filters Discrete EMI Filters Filter Connectors Gaskets & Shielding Ceramic Capacitors Single Line Filters Filtered Terminal Blocks Power Entry & Power Line Filters Military/Multisection Filters EMC Testing www.specemc.com [email protected] Microwave Components & Systems Lumped Element Filters Cavity Filters Bandpass Filters & Duplexers Tubular & Waveguide Filters Tower Mount Amplifiers Coaxial Resonators Patch Antennas & Assemblies Switchable Filter Bank Assemblies Low Noise Amplifiers Local Oscillator Doublers Microwave Synthesizers Couplers Integrated Microwave Sub-assemblies www.specwave.com [email protected] Sensors & Controls Element Segments & Wiper Assemblies Rotary Precision Potentiometers Linear Precision Potentiometers Motorized Potentiometers Hollow Shaft Potentiometers Custom & Value-added Assemblies www.specsensors.com [email protected] Updated 09/18/2009