Preview only show first 10 pages with watermark. For full document please download

Speed Queen Domestic Washer Technical Information

   EMBED


Share

Transcript

Speed Queen R Domestic WasherTechnical Information 120 V, 60 Hz Models SLW330RAW PSLW330RAW • Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. • Refer to Service Manual RS3100007 for detailed installation, operating, testing, troubleshooting, and disassembly instructions. • Refer to Parts Manual RP3100017 for part number information. ! CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS3100007. ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor before servicing, unless testing requires it. Models Power Source Voltage AC Amperage (Single Unit) Frequency Motor horsepower Receptacle Plug Dimensions Cabinet Height−overall Height of cabinet Width Depth Clearance−washer lid Weight Crated August 2000 SLW330RAW 120 VAC 10 A 60 Hz 1/2 6-20R 6-20P 43” 36” 27” 28” 17 1/2” 193 lbs. Models Wash cyles Water temperatures Water level Features Steady Spin Balance System Self-cleaning lint filter Self-adjusting rear leveling legs 210 Agitation stroke Tri−Action wash system Fabric softener dispenser SLW330RAW 7 3 Variable Motor speed Spin speed (revolutions per minute) Agitation speed (strokes per minute) High Medium 2 speed 640 / 427 rpm 1 X X X X X X 69 spm 46 spm RT3100014 Rev. 0 Component Testing Information ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. Illustration 40077101 1 Component Temperature switch 3 3 2 44 A B L1 L2 40097701 L1 = A L2 = B 3 = 1, 2 4 = 3, 4 Hot / Cold Warm / Cold Cold / Cold Mixing valve 40058801 Test Procedure Disconnect wires from component to properly measure the resistance of the component. Place switch in the following positions and measure across the terminals below: Timer L1-4  L1-3, L1-4, 3-4 L1-3  Results >1 Ω >1 Ω >1 Ω Measure resistance of terminals on each valve. Resistance across each valve. Approximately 1000 Ω ± 10% Verify input and output voltage is present. See timing sequence chart for functional description of the component. Verify wiring is correctly connected to the timer. 40077201 Pressure switch 2 1 3 40035001 R0000014 Lid switch−SPST Brake pad kit Do not disconnect the pressure hose from pressure switch to perform measurements. Measure resistance across the following terminals on the pressure switch: Terminal 1 to 2 Terminal 1 to 3 Air pressure that actuates switch is determined by the water level of the tub. Continuity (no pressure) Continuity (pressure) Disconnect wire terminals from switch. Test terminals with switch closed. Test terminals with switch open. Continuity Infinite If washtub does not stop spinning within seven seconds after opening loading door. Replace all three brake pads. If brake pads make noises. RT3100014 Rev. 0 Refer to wiring diagram/schematic for correct contacts. 2 >1 Ω 1 MΩ Apply a thin layer of silicone (26594P) on pads, see Service Bulletin “ASQ−213−B” August 2000 Component Testing Information ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. Illustration 40095001 Component Motor Test Procedure Type of motor: Two speed Results See following section “Internal Motor Diagram and Schematic” for correct wiring contacts. 40040301 Drain pump Verify drain pump is not clogged or damaged. Remove clog and verify proper operation. Replace drain pump if damaged. 40065301 Transmission assembly Type of transmission: 640 rpm Externally identical, must be identified by part number. If transmission locks-up, replace. 40053602 Drive belt Type of drive belt: 640 rpm Refer to “Parts Manual”, to verify which drive belt and pulley size is required. Refer to “Parts Manual” for proper pulley size. August 2000 3 RT3100014 Rev. 0 Internal Motor Diagram and Schematic ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. One or Two Speed Motors Continuity exists between switch terminal R and Red wire. Start Terminals YES Manually depress actuator. Continuity broken between switch terminal R and Red wire. YES Continuity exists between switch terminal P and Red wire. High Speed Terminals Low Speed Terminals NO NO Inoperative start switch. Replace switch. NO YES Manually depress actuator. Continuity broken between switch terminal P and Red wire. YES Continuity broken between switch terminal P and Violet wire. NO Inoperative high speed switch. Replace switch. NO YES Manually depress actuator. Continuity exists between switch terminal P and Violet wire. YES NO Inoperative low speed switch. Replace switch. Motor switch checks OK. Start Winding 4-5 ohms between Brown wire and Red wire. NO Inoperative start winding. Replace motor. NO Inoperative high speed winding. Replace motor. NO Inoperative low speed winding. Replace motor. NO Inoperative common lead. Replace motor. YES High Speed Winding 1-2 ohms between Blue wire and Yellow wire. YES Low Speed Winding 1-2 ohms between Yellow wire and Violet wire. YES Protector Continuity exists between Yellow wire and White wire. YES All motor windings checks OK. RT3100014 Rev. 0 4 August 2000 Internal Motor Diagram and Schematic ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. BR W BU Y P R Wire harness connection block White Brown Yellow Red Blue G P W R White RUN BR BU Y START Violet Red Violet Blue Brown Yellow 4P M Yellow Overload protector 6P M Aux. Motor Assembly (two speed motor) August 2000 5 RT3100014 Rev. 0 RT3100014 Rev. 0 6 F G FI MTR A K SA LO TM PS TM BP BLK 18 GA. BLU VLT BRN PNK BLK 5 20 10 11 14 9 WHT/BLK RED WHT/RED GRY/BLK PNK/BLU 3 6 17 15 8 19 RED/BLK 23 P ORG GROUND TO TOP WHT CONNECTOR A 3 B 1 GRN N.O. 3 POSITION TEMP. SWITCH GROUND TO CONTROL HOOD 2 3 COM. PNK/BLU PNK BLU VLT BRN ORG GRN/YEL GRY WHT/RED 1 3 2 9 POWER CORD 7 6 5 4 8 RIDGE OR TINNED TERMINAL = NEUTRAL LID SWITCH PRESSURE SWITCH 1 RED/BLK GROUND TO TOP GRN/YEL 7 6 5 4 8 1 3 2 9 WHT/RED PNK BLU VLT BRN WHT GRN/YEL 5 8 3 7 1 6 4 5 8 3 7 1 6 4 RED NATURAL MOTOR HOUSING GRY ORG WHT/RED PLUG GRN/YEL RECEPTACLE HOT COLD MIXING VALVE ! L GRY BLU/BLK 24 22 24 PIN HOUSING V H TIMER CONNECTION DIAGRAM GROUND TO CABINET Wiring Diagram and Schematic To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. WARNING August 2000 Wiring Diagram and Schematic ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. SCHEMATIC L1 N 120 VOLTS A.C. 60 HZ BP A FI PS PRESSURE SWITCH MIXING VALVE COLD SIS 3 1 2 HOT P 3 POSITION WATER TEMP. SWITCH HOT COLD WARM COLD COLD COLD LID SWITCH V H A-1 N.O. 3 POSITION WATER TEMP. SWITCH A-1, B-3 B-3 B A SPRAY RINSES = COLD 3 1 LO MTR SIS SA TM 3 HI K HIGH 7 TIMER MOTOR F L MOTOR LOW 1 4 START 6 TP AGITATE K G 8 SPIN L INDICATES INTERNAL TIMER BUSS August 2000 7 RT3100014 Rev. 0 Timer Cycle Chart To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless testing requires it. SPRAY & AGIT SIS C R SWITCH A A M D FUNCTION T MTR-SIS MTR-LO T 6B T 10 A-BP TM-HI 1 2 6 8 9 40 P A U S E SPIN 50 P A U S E R I N S E P A U S E SPIN T M O F F F I L L S S P I N P A U S E R I N S E R I N S E S T P M I N O F F S O A K A G I T A T E S O A K A G I T A T E S O A K P A U S E S S P I N & S 330 R I N S E HAND WASH S P I N 310 & S 250 DELICATE 240 S P I N S O A K 230 A G I T A T E S O A K 220 A G I T A T E S O A K 280 PART NO. 40101201 210 A G I T A T E P A U S E S P I N T M 350 SPIN 180 PERMANENTPRESS P A U S E 320 O F F 360 61 62 63 64 65 66 340 R I N S E 300 SPIN P A U S E 270 48 49 50 51 52 53 54 55 56 57 58 59 60 290 WASH S 160 CONTACTS CLOSED 200 S S P & I N 150 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 260 O F F 130 CONTACTS OPEN 190 THIS MACHINE MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING PATENTS: UNITED STATES NO: 3,253,874; 3,838,755; 3,8453642 CANADIAN NO: 1,008,265; 994,685 OTHER PATENTS PENDING 170 P A U S E 140 T M 120 S S P I N 100 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 90 Failure to install, maintain, and/or operate this machine according to manufacture's instructions may result in conditions which can produce bodily injury and/or property damage. 110 & S 10 11 12 13 80 REGULARWASH 30 7 70 WASH 3 4 5 TERM DEGREES IDENT LOW MOTOR PS-SIS PS-FI SIS-SA FILL SIS FILL F-K F-L T LOW MOTOR SIS 0B 2 T B AGITATE SPIN G-K G-L 4B SPIN AGITATE 8B B HIGH MOTOR T T PRES SW BYPASS 10 12 B P-H P-V INTERVAL NUMBER 60 TIMER CHART HOT WATER COLD WATER 14 BT 20 SA SIS SIS SIS MTR PS LO FI K H BP K F G L L TM P A HI V 3 5 2 8 11 BLU 10 7 4 1 24 PIN HOUSING WIRE POSITION 6 RED 9 WHT/ PNK BLK VLT 13 19 16 14 BLK GRY/ x 2 BLK 12 15 23 22 BLK PNK/ BLU 20 RED 17 WHT/ BRN RED 18 21 24 GRY RED/ BLU/ BLK BLK August 2000 8 RT3100014 Rev. 0 WARNING ! KEY "A" INDICATES 27 SECOND WATER ON ±7 SECONDS. "B" INDICATES 27 SECOND MOTOR ON ±7 SECONDS.