Preview only show first 10 pages with watermark. For full document please download

Split Type Air Conditioner Ceiling Type (50hz) Abyg36lrta

   EMBED


Share

Transcript

SPLIT TYPE AIR CONDITIONER CEILING TYPE (50Hz) Indoor unit Outdoor unit ABYG36LRTA AOYG36LATT ABYG45LRTA AOYG45LATT ABYG54LRTA AOYG54LATT CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . . 4 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . 5 INDOOR PCB CIRCUIT DIAGRAM . . . . . . 6 OUTDOOR PCB CIRCUIT DIAGRAM . . . 10 ERROR DETECTION. . . . . . . . . . . . . . . .17 PARTS (INDOOR UNIT) . . . . . . . . . . . . . 21 PARTS (OUTDOOR UNIT) . . . . . . . . . . . 26 ACCESSORIES . . . . . . . . . . . . . . . . . . . . 29 SPECIFICATIONS ELECTRICAL DATA NOISE LEVEL Cooling & Heating TYPE INDOOR UNIT ABYG36LRTA ABYG45LRTA ABYG54LRTA OUTDOOR UNIT AOYG36LATT AOYG45LATT AOYG54LATT COOLING CAPACITY 10.0 kW 12.5 kW 14.0 kW HEATING CAPACITY 11.2 kW 14.0 kW 16.0 kW POWER SOURCE OUTDOOR UNIT 400 V, 50 Hz, 3 phase, 4 W 47 dB 49 dB 51 dB Medium 43 dB 45 dB 48 dB Low 37 dB 39 dB 42 dB Quiet 32 dB 34 dB 38 dB Cooling 51 dB 54 dB 55 dB Heating 53 dB 54 dB 56 dB Cooling 4.3 A 5.8 A 6.9 A Heating 4.4 A 5.8 A 6.9 A Cooling 2.84 kW 3.89 kW 4.65 kW Heating 2.87 kW 3.88 kW 4.67 kW E.E.R. Cooling 3.52 kW/kW 3.21 kW/kW 3.01 kW/kW DISCRIMINATION DA422A3F-29ZAD C.O.P. Heating 3.90 kW/kW 3.61 kW/kW 3.43 kW/kW WEIGHT (with oil) 23.0 kg 3.0 L/hr 4.5 L/hr 5.0 L/hr REFRIGERANT TYPE R410A 1,900 m3/h 2,100 m3/h 2,300 m3/h PRECHARGED REFRIGERANT 3,450 g Cooling 6,200 m3/h 6,750 m3/h 6,900 m3/h Heating 6,200 m3/h 6,200 m3/h 6,900 m3/h 7.9 A 8.9 A 9.9 A RUNNING CURRENT INPUT WATTS MOISTURE REMOVAL AIRCIRCULATION INDOOR AIRCIRCULATION OUTDOOR MAXIMUM CURRENT COMPRESSOR AND REFRIGERANT INDOOR UNIT, Discrimination INDOOR UNIT 30 m Pipe length 30 m 3,450 g 45 m 4,200 g 60 m 4,950 g 75 m 5,700 g ADDITIONAL CHARGE MFH-45RV 1,200 r.p.m. 1,360 r.p.m. Medium 910 r.p.m. 1,000 r.p.m. 1,150 r.p.m. Low 750 r.p.m. 830 r.p.m. 950 r.p.m. Quiet 650 r.p.m. 680 r.p.m. 790 r.p.m. OUTDOOR UNIT, Discrimination MAX PIPE HEIGHT FULL CHARGE 1,100 r.p.m. High Hermetic type, Inverter, 4 poles, 3 phase, DC motor, Twin Rotary TYPE FAN MOTOR 2012.05.08 INDOOR UNIT High MFE-54VVT OUTDOOR UNIT Cooling Upper fan 780 r.p.m. 850 r.p.m. 900 r.p.m. Lower fan 750 r.p.m. 800 r.p.m. 800 r.p.m. OUTDOOR UNIT Heating Upper fan 780 r.p.m. 780 r.p.m. 870 r.p.m. Lower fan 750 r.p.m. 750 r.p.m. 840 r.p.m. 50 g/m DIMENSIONS INDOOR UNIT HxWxD 240 x 1,660 x 700 mm OUTDOOR UNIT HxWxD 1,290 x 900 x 330 mm WEIGHT INDOOR UNIT Shipping / Net OUTDOOR UNIT Shipping / Net 1 58 kg / 46 kg 60 / 48 113 kg / 104 kg DIMENSIONS INDOOR UNIT 700 (Unit : mm) 240 130 300 1,660 1,600 2008.11.25 2 OUTDOOR UNIT (unit : mm) 31 330 9 21 1290 900 400 370 air flow 650 2008.11.25 3 12 REFRIGERANT SYSTEM DIAGRAM OUTDOOR UNIT INDOOR UNIT Refrigerant Pipe 15.88mm (5/8") Pressure Check Valve Strainer 4-way Valve Heat Exchanger Heat Exchanger Accumulator Expansion Valve Strainer Thermistor (Compressor) Thermistor (Discharge) Refrigerant Pipe 9.52mm (3/8") 3-Way Valve Thermistor (Room) Thermistor (Pipe) Thermistor (Heat Exchanger Med) Thermistor (Heat Exchanger Out) Thermistor (Outdoor) 2012.04.09 Heat Pressure Sensor Compressor Strainer Cool 3-Way Valve Muffler 4 Refrigerant flow CN103 1 2 EX. IN EX. OUT ( OPTION ) 1 2 3 TERMINAL TO WIRED REMOTE CONTROL (option) RED WHITE TM803 BLUE ACTIVE FILTER PCB TM301 W703 TM501 WHITE TM302 BLACK TM502 BLACK TM504 THERMISTOR ( HEATSINK INV ) CN803 1 1 2 2 BLACK 1 1 2 2 3 3 WHITE CN802 TM805 TM804 V U TM505 BLACK 1 1 2 2 CN200 3 3 BLACK TM203 W301 TM204 BLACK CM BROWN YELLOW WHITE RED F2 3.15A 250V FUSE F3 10A 250V W1 TM205 TM202 W206 R S FUSE W302 FILTER PCB RED BLACK FAN MOTOR 2 ( LOWER ) W702 W300 BROWN FAN MOTOR 1 ( UPPER ) YELLOW ORANGE WHITE BLUE GREEN YELLOW ORANGE RED BROWN GREEN TM802 PURPLE YELLOW BLACK RED WHITE EXPANSION VALVE COIL ORANGE YELLOW BLUE RED BROWN BLUE BLACK BLACK BLUE REACTOR (FAN) PRESSURE SENSOR BLACK RED BROWN BROWN BLUE BLUE SOLENOID COIL RED TM500 TRANSISTOR PCB TM806 W RED W700 W800 3 TM300 ORANGE BLACK 2 REACTOR x3 TM801 W701 TERMINAL WHITE CN630 F1 5A 250V GREEN BLACK TM201 WHITE TM200 RED TERMINAL W3 1 2 CN101 W4 1 2 3 4 5 1 2 3 4 5 3 L1 L2 WHITE BLACK FUSE 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 CAPACITOR PCB CN801 1 2 3 1 2 3 CN19 1 2 3 1 2 3 CN18 MAIN PCB CN9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 W5 1 2 3 4 5 6 1 2 3 4 5 6 CN82 1 2 3 4 5 6 1 2 3 4 5 6 CN81 BLUE WHITE WHITE COIL THERMISTOR ( COMPRESSOR TEMP. ) THERMISTOR ( OUTDOOR TEMP. ) THERMISTOR ( HEAT EXCHANGER OUT ) BLACK BROWN BROWN BLACK BLACK BLACK 1 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RED 1 CN104 1 2 1 2 3 4 5 6 1 2 3 4 5 6 CN17 BLACK GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN102 E101 E102 1 2 3 1 2 CN108 1 2 CN106 CN21 1 2 1 2 1 2 CN103 OPTION ( CONNECTOR ) REFER TO THE TECHNICAL MANUAL RED RED F101 FUSE 3.15A 250V POWER SUPPLY PCB 1 2 3 1 2 3 CN101 W105 W102 W101 CN20 FM WHITE BLACK GRAY INDICATOR PCB W6 FM BLACK YELLOW WHITE GREEN GREEN / YELLOW 1 2 3 4 5 6 7 8 1 2 3 4 5 6 PURPLE CN1 1 2 3 1 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN104 CN105 GREEN FM 1 2 3 4 5 6 7 8 1 2 3 4 5 6 GRAY GRAY CN4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 BROWN BLUE 1 CN6 2 1 CN10 2 FAN MOTOR WHITE CN7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 EV BLACK 1 1 CN14 2 2 3 3 1 2 CN9 3 ORANGE 1 2 3 4 5 6 7 8 1 2 1 2 CN102 1 2 3 1 2 3 CN16 4WV WHITE WHITE RED 1 2 3 4 5 6 7 8 1 2 3 1 2 3 CN27 1 2 3 1 2 3 CN26 RED YELLOW 1 2 3 CN11 4 5 1 2 3 4 5 6 7 8 BROWN 1 2 3 1 2 3 CN25 GREEN RED ORANGE 1 2 3 4 5 MAIN PCB 1 2 3 4 5 6 7 GREEN WHITE BROWN 1 2 3 CN13 4 5 6 7 YELLOW YELLOW 1 2 3 CN12 4 5 1 2 3 1 2 3 CN24 ORANGE ORANGE 1 2 3 4 5 1 2 1 2 CN23 1 2 1 2 CN22 GRAY M 1 2 3 4 5 RED GRAY STEPPING MOTOR 1 2 3 4 5 BROWN 1 2 3 CN3 4 5 6 WHITE M 1 2 3 4 5 1 2 1 2 CN8 WHITE STEPPING MOTOR 1 2 3 4 5 1 2 CN7 BLACK THERMISTOR ( ROOM TEMP. ) BLACK PS BLACK BLACK 1 2 1 2 CN5 THERMISTOR ( DISCHARGE PIPE ) THERMISTOR ( PIPE TEMP. ) GRAY WHITE GRAY RED 1 1 2 2 BLACK BROWN BLACK INDOOR UNIT THERMISTOR ( HEATSINK PFC ) OUTDOOR UNIT THERMISTOR ( HEAT EXCHANGER MID ) CIRCUIT DIAGRAM L3 N C COMPRESSOR POWER SOURCE 2012.07.25 5 INDOOR PCB CIRCUIT DIAGRAM CONTROL UNIT ABYG36LRTA : EZ-0122DHSE ABYG45LRTA : EZ-0122EHSE ABYG54LRTA : EZ-01234HSE 2-1 2-2 2-3 2-4 2-5 CN2 B5P-SHF-1AA WHITE CN8 B02B-XASK-1-A WHITE 8-1 8-2 CN7 B02B-XAYK-1-A 7-1 7-2 CN5 B02B-XAKK-1-A 5-1 5-2 YELLOW 15-1 15-2 15-3 15-4 15-5 15-6 TERMINAL 3 CN15 B6B-XASK-1-A BLACK BLACK THERMISTOR ( ROOM TEMP. ) BLACK BLACK GRAY GRAY THERMISTOR ( PIPE TEMP. ) BLACK WHITE INDICATOR PCB K04GN-1100HSE-D0 RED MAIN PCB ABYG36LRTA : K06AK-1212HSE-C1 ABYG45LRTA : K06AK-1213HSE-C1 ABYG54LRTA : K06AK-121GHSE-C1 WHITE DC FAN MOTOR FM BLACK WHITE YELLOW BROWN CN105 B5P6-VH-B WHITE WHITE 14-1 14-2 14-3 E102 105-6 105-5 105-4 105-3 105-2 105-1 RED CN14 B03B-XAKK-1-A BLACK EMI FILTER ZCAT1518-0730 2 TURNS POWER SUPPLY PCB K06AL-1105HSE-P0 1 2 3 4 5 6 7 8 CN201 JC25-08HG CN3 B06B-PASK-1 UL1015 AWG16 GREEN UL1430 AWG28 x 7 POWER DRIVE CN104 B08B-PASK-1 WHITE 104-1 104-2 104-3 104-4 104-5 104-6 104-7 104-8 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY 201-1 201-2 201-3 201-4 201-5 201-6 201-7 201-8 CN6 B02B-PAMK-1 CN4 B08B-PASK-1 GREEN 6-1 6-2 BLACK E101 BROWN RED ORANGE YELLOW WHITE BLUE PURPLE GRAY WHITE GREEN 1 2 3 4 5 6 7 8 UL1430 AWG22 3-1 3-2 3-3 3-4 3-5 3-6 UL1015 AWG16 WHITE BLUE PURPLE GRAY 1 2 3 4 5 6 7 8 UL1430 AWG22 W105 BROWN RED ORANGE RED W102 WHITE 13-1 13-2 13-3 13-4 13-5 13-6 13-7 UL1430 AWG22 W101 CN13 B07B-PASK-1 UL1015 AWG20 UL1015 AWG20 OUTDOOR UNIT UL1015 AWG20 BLACK 1 WHITE 2(N) 1 2 3 FRESH AIR WHITE TERMINAL UL1430 AWG26 x 8 UL1015 AWG22 x 5 EARTH WIRE EMI FILTER GTFC-25-15-12 2 TURNS DRAIN PUMP 106-1 106-2 CN106 B2P3-VH-B-E BLUE CN10 B02B-PAOK-1 DC SUPPLY CN101 B03B-PASK-1 WHITE 101-1 101-2 101-3 GRAY GRAY GRAY ORANGE 1-1 1-2 1-3 10-1 10-2 CN1 B03B-PASK-1 WHITE UL1430 AWG26 x 3 WIRED REMOTE CONTROL ( OPTION ) EMI FILTER ZCAT1518-0730 2 TURNS EX. OUT 103-1 103-2 CN103 B2B-XH-AM WHITE CN11 B05B-XASK-1-A 11-1 11-2 11-3 11-4 11-5 CN12 B05B-XARK-1-A 12-1 12-2 12-3 12-4 12-5 WHITE 102-1 EX. I N 102-2 102-3 108-1 108-2 NORMAL COIL RLEY41-22 22mH, 2.2A 2013.03.07 CN102 B3B-XH-AM RED WHITE CN9 B03B-XARK-1-A CN108 B2P3-VH-B RED WHITE UL1015 AWG20 x 2 6 9-1 9-2 9-3 BROWN RED ORANGE YELLOW WHITE BROWN RED ORANGE YELLOW WHITE M LOUVER ( UP / DOWN ) M LOUVER ( RIGHT / LEFT ) UL1430 AWG28 x 5 BROWN RED ORANGE YELLOW WHITE UL1430 AWG28 x 5 FLOAT SWITCH BROWN RED ORANGE YELLOW WHITE INDOOR UNIT MAIN PCB ABYG36LRTA : K06AK-1212HSE-C1 ABYG45LRTA : K06AK-1213HSE-C1 ABYG54LRTA : K06AK-121GHSE-C1 5V D4 1SS355 13.5V CN1 B03B-PASK-1 1 DC SUPPLY 2 3 I R45 10k <1/10W> 12V O 3 G C1 + 10/ 50V R1 - R3 10k <1/10W> x 3 JM1 C2 + 10/ 50V 2 C31 0.01 JM3 D1 1SS355 1 I 5V O 3 G 2 C32 + 100/ 6.3V R15 - R18 10k <1/10W> x 4 CN2 B5P-SHF-1AA C33 0.1 3 C8 - C10 0.1 x 3 5V C3 0.01 2 C29 0.1 R57 1.0k <1/10W> R59 10k <1/10W> C30 0.1 R58 1.0k <1/10W> R60 49.9k <1/10W> C34 0.1 R62 1.0k <1/10W> R61 49.9k <1/10W> CN7 B02B-XAYK-1-A 1 2 CN5 B02B-XAKK-1-A 1 THERMISTOR ( PIPE TEMP. ) 2 R4 - R6 1.0k <1/10W> x 3 5V I C2 NJM7805 CN9 B03B-XARK-1-A R46 1.0k <1/10W> THERMISTOR ( ROOM TEMP. ) 2 FLOAT SWITCH 1 JM2 CN8 B02B-XASK-1-A 1 5V I C8 NJM7812 1 5V 5V C28 0.1 5V 1 2 3 R19 - R22 1.0k <1/10W> x 4 1 5 6 3 4 C5 1000p C4 0.01 5 C7 1000p 13.5V CN3 B06B-PASK-1 R66 10k <1/10W> R63 - R65 1.0k <1/10W> x 3 1 2 34 39 36 43 44 45 46 33 32 31 30 29 28 27 26 18 19 20 21 22 23 11 12 13 14 38 37 41 40 25 9 42 R70 10k <1/10W> 3 SP PCB 4 5 6 R67 1.0k <1/10W> 5V C37 0.1 C35, C12, C11 1000p x 3 R26 10k <1/10W> 3 C14 1000p R25 1.0k <1/10W> C36 0.47 Q3 DTC124EKA 1 2 5V R28 10k <1/10W> CN4 B08B-PASK-1 1 2 C15 0.01 5 6 FRESH AIR 2 CN10 B02B-PAOK-1 13.5V 2 VDD NC 3 1 OUT GND 4 5V NC R68, R52 10k <1/10W> x 2 R43, R44 10k <1/10W> R41 x2 1.0k <1/10W> C38 0.1 R37 10k <1/10W> 1 2 3 6 2 5V VCC 8 DO 4 NC 7 GND 5 CS SK DI NC 3 4 C13 0.1 C23 0.01 C24 1000p I C5 S-93C66BD0 I I C6-2 BA10393F - 6 7 5V + 5 R55 10k <1/10W> C25 + 10/ 50V R42 47 <1/10W> I C6-1 BA10393F - 2 1 8 7 6 5 6 7 R54 15.4k <1/10W> + 3 2 5V C17 0.01 R47 390 <1/10W> D2 R53 12V DAN217U 28k <1/10W> 1 3 1 4 3 2 1 2 C19 0.1 C18 0.01 C20 - C22 0.1 x3 2 12V CN14 B03B-XAKK-1-A D3 D1FS4A 1 2 3 3 R48 10k <1/10W> R36 0R0 BZ BZ1 PKM13EPYH-4000-A0 13.5V I C4 uLN2003 1 2 3 4 5 6 7 I1 I2 I3 I4 I5 I6 I7 SK O1 O2 O3 O4 O5 O6 O7 GND 9 16 15 14 13 12 11 10 8 1 3 I1 I2 I3 I4 I5 I6 I7 LOUVER ( UP / DOWN ) 4 5 CN12 B05B-XARK-1-A 2 I C3 uPA2003 SK O1 O2 O3 O4 O5 O6 O7 GND CN11 B05B-XASK-1-A 2 1 9 16 15 14 13 12 11 10 8 WIRED REMOTE CONTROL ( OPTION ) R35 1.0k <1/10W> Q2 DTC124EKA R11 - R14 10k <1/10W> x 4 R7 - R10 1.0k <1/10W> x 4 13.5V I NDICATOR PCB 5 C26 0.01 12V 13.5V SW1 CFS-0402MC CN13 B07B-PASK-1 5V 1 2 R33 10k <1/10W> 1 I C7 S80842 R40 10k <1/10W> C16 0.01 R31 10k <1/10W> CN6 13.5V B02B-PAMK-1 C27 0.1 5V X1 8.00MHz 8 R34 1.0k R27 <1/10W> 330 <1/10W> R56 100k <1/10W> 1 Q1 DTC124EKA 7 5V JM5 0R0 35 10 24 15 16 17 57 58 59 60 61 62 63 64 1 2 3 4 5 6 7 8 53 54 55 56 47 48 49 50 51 52 R29 390 <1/10W> 1 4 POWER DRIVE AVREF AVDD VDD0 IC RST* VDD1 P00 P34 P01 P35 P02 P36 P03 P40 P41 P10 P11 P42 P43 P12 P13 P44 P14 P45 P15 P46 P16 P47 P50 P17 P51 P20 P21 P52 P22 P53 P23 P54 P55 P24 P25 P56 P30 P57 P31 P64 P32 P65 P33 P66 XT1 P67 XT2 P70 X1 P71 X2 P72 AGND P73 GND0 P74 GND1 P75 3 3 3 R69 10k <1/10W> I C1 uPD78F0536 R24, R23, R32 5V 10k <1/10W> x 3 2013.03.07 FLASH 4 2 TEST HEATER CN15 B06B-XASK-1-A 5V R50 10k <1/10W> 3 4 1 2 3 4 5 6 7 5 1 2 7 LOUVER ( RIGHT / LEFT ) NORMAL COIL CN108 B2P3-VH-B 2 1 R103 62k 340V C108 4700p L I C26-14 R104 330k <2W> F101 3.15A 250V LF101 ELF20N018A FC51FL x 2 W101 BLACK 1 1 3 FH101 FH102 W102 C101 0.22 VA101 470V WHITE C104 0.22 4 SA101 RA-362M 4 C107 270/ 450V C106 0.010 3 2 R105 75 2 C105 0.010 2 C109 220p D101 D3SB60 VA102 470V D107 RD16 Q102 2SC1815 + 2 1 R107 100 <1/10W> R106 1.5 3 GREEN 12 10 R111 10k <1/10W> D103 R108 D1FL20U 100 <1/2W> D104 D105 MTZJ5.1B D1FL20U D109 MTZJ5.1B R110 10k <1/10W> C113 1000/ 25V C115 0.01 D106 D1FL20U C110 0.047 C112 + 330/ 25V + C114 0.01 1 3 C118 0.01 E102 15V 13.5V T101 ZFT22B03-C 2 3 5 6 7 8 D102 1SR139-600 Q101 2SC5354 D108 D2FL20U R109 C111 330 100/ + <1/4W> 25V A I C26-10 N E101 GREEN CN105 B5P-VH-B 340V 15V 6 C119 0.01 5V 1 2 1 4 I C104 15V TLP621 R116 1.0k 4 <1/4W> IC105 HI2003R3 DC FAN MOTOR 3 A 2 1 3 + C117 R117 820 100/ <1/4W> A A25V CN104 B08B-PASK-1 5 4 3 I C103 TLP621 15V 18 8 1 2 R114 4.7k <1/10W> W105 R115 6.8k <1/4W> RED VA103 0.01 14 10 7 6 4 5 5 4 3 3 2 2 1 1 5V SERIAL 2 3 POWER DRIVE I C26-14 4 I C26-10 L 5 INDOOR UNIT POWER SUPPLY PCB K06AL-1105HSE-P0 N 6 7 8 R113 330 <1/10W> K101 G5NB-1A 13.5V 4 1 2 3 CN103 B2B-XH-AM 1 2 5V CN101 B03B-PASK-1 2 3 C121 0.1 C120 0.1 4 3 2012.02.29 I C26-14 L102 5V BLm18 1 DC SUPPLY EX. OUT 13.5V I C101 TLP621 L R112 330 <1/10W> 3 1 1 2 L103 BLm18 3 2 1 4 2 13.5V RC101 120/ 0.2 CN102 B3B-XH-AM 2 CN106 B2P3-VH-B-E K102 G5NB-1A I C26-10 N EX. I N C116 0.01 8 1 DRAIN PUMP INDOOR UNIT INDICATOR PCB K04GN1100HSE-D0 5V CN201 08 / 08 JC / XMR 1430 L=300 TO MAIN PCB OPERATE BROWN 1 TIMER RED 2 LOUVER ORANGE 3 LOUVER YELLOW 4 5V WHITE 5 REMOTE SIGNAL BLUE 6 GND PURPLE 7 MANUAL AUTO SWITCH GRAY 8 R201 330 <1/4W> D205 EMPG3863X GREEN R202 330 <1/4W> D206 EMAA3863X ORANGE R203 330 <1/4W> D207 EMPG3863X GREEN C202 + 10/ 16V SW201 EVQPAG04K C201 0.1 JM201 PHA201 P I C-37143TH5 VCC OUT GND 2012.02.28 9 2 1 3 OUTDOOR PCB CIRCUIT DIAGRAM REACTOR L1 - L3 17mH 14A x 3 UL1007 AWG24 WHITE BLACK 1 BLACK 2 WHITE 3 RED L3 OUT TM205 W206 B GREEN UL1015 AWG20 BLACK FILTER PCB K07AQ-0700HUE-FL0 E UL1015 AWG20 UL1015 AWG14 TM302 TM502 L2 L3 W300 B L1 I N W301 B L2 I N W302 B L3 I N TM504 DC+OUT ACTIVE FILTER PCB K11BZ-1100HUE-AF0 TM505 N OUT 1 UL1015 AWG12 W800 B DC+I N ORANGE UL1015 AWG12 PURPLE UL1015 AWG12 ORANGE 1 2 4 3 5 1 2 3 4 5 6 7 8 9 RED CT OUT RED ORANGE YELLOW GREEN BLUE UL1007 AWG24 UL1007 AWG24 UL1007 AWG24 UL1007 AWG24 GREEN BROWN BLACK BLACK UL1007 AWG24 GREEN UL1015 AWG20 UL1015 AWG20 UL1015 AWG16 6 5 TM804 U CN800 B06B-PASK TM805 V WHITE FLASH TM806 W TRANSISTOR PCB K11CA-1200HUE-TR1 TM801 P OUT UL3271 AWG12 RED UL3271 AWG12 WHITE CM UL3271 AWG12 BLACK COMPRESSOR CN801 1971032-8 WHITE TM803 1 2 3 4 5 6 7 8 N IN 1 2 3 7 8 9 EMI FILTER GRFC-10 1 TURN EMI FILTER GRFC-10 1 TURN W700 B P IN UL1007 AWG24 WHITE REACTOR 17mH 3A UL1015 AWG20 BLUE UL1015 AWG20 BLACK BLUE 4 3 WHITE 6 EMI FILTER ZCAT1518-0730 2 TURNS UL1015 AWG20 CN803 1-1971032-2 2 CN630 1971032-9 WHITE EMI FILTER ZCAT2132-1130 2 TURNS THERMISTOR ( HEATSINK TEMP. ) W701 B N IN CAPACITOR PCB K07AP-0700HUE-P0 W702 B P OUT W703 B N OUT EMI FILTER ZCAT1518-0730 2 TURNS UL1015 AWG12 YELLOW UL1015 AWG12 BLUE 1 2 3 7 8 EARTH W6 B PRESSURE SENSOR PS CN802 2-1871843-3 1 2 TM802 P IN CN650 B06B-PASK EARTH 1 3 FLASH EARTH UL1015 AWG16 2 GREEN BLUE UL1015 AWG20 WHITE TM301 TM501 L1 YELLOW I NDOOR UNIT UL1015 AWG16 L2 OUT TM204 P202 L3 I N TM202 BLACK CT OUT UL1015 AWG14 TM300 TM500 UL1007 AWG24 N P201 RED BLACK BLACK UL1007 AWG24 BLACK UL1015 AWG14 L1 OUT TM203 BLUE L2 I N TM201 WHITE UL1015 AWG14 UL1015 AWG14 UL1015 AWG14 WHITE WHITE ORANGE L3 UL1015 AWG14 3 UL1015 AWG14 UL1015 AWG14 RED L2 WHITE P200 L1 I N TM200 RED 2 CN200 2-1871843-3 RED UL1007 AWG24 POWER SOURCE AC380 - 415V 50Hz L1 RED 1 UL1015 AWG14 BROWN RED UL1007 AWG24 UL1015 AWG14 UL1015 AWG14 THERMISTOR ( HEATSINK TEMP. ) UL1007 AWG24 UL1007 AWG24 INVERTER ASSEMBLY AOYG36LATT : EZ-01222HUE AOYG45LATT : EZ-0111WHUE AOYG54LATT : EZ-0111YHUE RED 1 WHITE 2 BLACK 3 1 2 CN1 1871843-3 W4 B SERIAL W3 B W1 B 1 F3 WHITE 10A 250V 3 W5 B 5 CN101 B3P5-VH-B F1 WHITE AC I N 5A 250V CN21 2-1971032-2 1 2 4 5 6 CN102 2-1747052-3 CN9 1971032-9 REACTOR P.F.C. PCB BLUE 1 2 CN23 1-1971032-2 WHITE RED 2 3 4 5 CN6 B06B-PASK-1 WHITE 6 4 5 6 CN7 1971032-8 WHITE 1 FLASH RED 2 CN81 B6P-VH-B F2 BLUE 1 WHITE 3.15A 250V 3 BLACK 4 WHITE 5 YELLOW 6 BROWN 1 RED FM DC FAN MOTOR 1 ( UPPER ) FM DC FAN MOTOR 2 ( LOWER ) EV EXPANSION VALVE COIL THERMISTOR ( PIPE M I D. TEMP. ) 1 2 CN22 1971032-2 WHITE CN82 B6P-VH-B-C BLACK 1 2 THERMISTOR ( PIPE TEMP. ) 1 2 3 THERMISTOR ( DISCHARGE TEMP. ) 1 2 3 THERMISTOR ( COMPRESSOR TEMP. ) YELLOW MAIN PCB AOYG36LATT : K07AK-1200HUE-C1 AOYG45LATT : K07AK-1101HUE-C1 AOYG54LATT : K07AK-1102HUE-C1 CN25 1-1971032-3 RED 3 1 2 3 BLACK 4 WHITE 5 YELLOW 6 BROWN EMI FILTER GRFC-8 1 TURN 1 RED 2 BROWN 3 BLUE 4 ORANGE 5 YELLOW 6 WHITE CN103 1747052-1 1 BLACK 2 BLACK CN104 3-1747052-4 1 CN17 B6B-XARK-1-A RED CN24 3-1971032-3 YELLOW CN27 2-1971032-3 WHITE BLUE CN26 1971032-3 WHITE EX. OUT EX. I N CN18 B03B-XASK-1-A CN19 B03B-XAKK-1-A WHITE 1 2013.03.07 3 4-WAY VALVE COIL 1 2 THERMISTOR ( OUTDOOR TEMP. ) CN20 3-1971032-2 2 2 3 YELLOW BLACK 1 2 3 10 2 OUTDOOR UNIT MAIN PCB AOYG36LATT : K07AK-1200HUE-C1 AOYG45LATT : K07AK-1101HUE-C1 AOYG54LATT : K07AK-1102HUE-C1 REACTOR CN102 2-1747052-3 WHITE AC I N L101 RCV1904-050PF07 FH2 FH1 5 S 4 N F1 5A 250V 1 T B 1 12V 2 C106 0.22 C105 0.01 2 1 VA2 470V P I N 102 3 2 1 4 2 5V 3 4 L151 BL02Rn1 C113 + 500/ 450V K101 G5NB-1A FH5 W1 L BLAXK W6 EARTH 4 F2 3.15A 250V VA3 470V B C110 0.01 C111 0.01 3 1 2 D5 1SS355 C112 0.22 R10 0R0 B 14 18 8 7 10 5V 6 5 4 3 2 1 RED CN103 1747052-1 WHITE 4-WAY VALVE CN104 3-1747052-4 YELLOW CR1 RE1202 1 2 CR2 RE1202 1 2 12V 12V 2 3 1 4 3 2 1 R51 5V 27k <1/10W> R50 47k <1/10W> K1 G5NB-1A C51 R55 0.01 4.7k <1/10W> R52 1.0k <1/10W> K2 G5NB-1A 12V 16 15 14 13 12 11 10 9 1C 2C 3C 4C 5C 6C 7C COM 1B 2B 3B 4B 5B 6B 7B E 1 2 3 4 5 6 7 8 P_PR P_SO P_4WV_AC P_V2 P_LED1 P_LED2 P_LED3 D31 WHITE PRESSURE SENSOR CN21 2-1971032-2 BLUE JM161 0R0 1 2 JM162 0R0 5V 2 1 CN25 1-1971032-3 THERMISTOR ( PIPE TEMP. ) CN22 1971032-2 WHITE THERMISTOR ( PIPE-M ID. TEMP. ) CN24 3-1971032-3 YELLOW THERMISTOR ( DISCHARGE TEMP. ) CN27 2-1971032-3 BLUE THERMISTOR ( COMPRESSOR TEMP. ) 3 2 1 2 1 3 2 1 3 2 1 CN26 1971032-3 3 THERMISTOR ( OUTDOOR TEMP. ) CN23 1-1971032-2 1 WHITE RED THERMISTOR ( HEATSINK TEMP. ) CN20 3-1971032-2 YELLOW 2013.03.07 C162 0.1 3 2 2 1 2 1 R33 R34 R35 R36 3 3 C53 0.01 Q51 2 2SC2412K P_S I Q32 DTA143EUA C161 0.1 L20 BL02Rn1 R121 4.75k <1/10W> 1% R21 10k <1/10W> C21 0.1 R125 4.75k <1/10W> 1% R25 10k <1/10W> C25 0.1 R122 4.75k <1/10W> 1% R22 10k <1/10W> C22 0.1 R124 13k <1/10W> 1% R24 10k <1/10W> C24 0.1 R127 13k <1/10W> 1% R27 10k <1/10W> C27 0.1 R26 10k <1/10W> D32 SLR-325VC ORANGE x7 3 2 1 1 Q33 DTA143EUA 3 2 3 C26 0.1 R123 1.5k <1/10W> 1% R23 10k <1/10W> C23 0.1 R120 4.7k <1/10W> 1% R20 10k <1/10W> C20 0.1 P_AN_PS P_AN_TS P_AN_TT 1 2 3 4 P_LED_COM3 EX. OUT 4 1 3 3 2 D182 1SS355 P_AN_TD 1 2 BLACK 3 4 JM191 0R0 P_POWER P_SO P_S I P_DEMAND2 P_DEMAND1 P_SRV1 P_SRV2 2 P_SRV1 Q181 DTC143EUA 2 5V 5V 1 4 2 3 1 4 2 3 I C192 PS2561L-1-V R198 D192 10k 1SS355 <1/10W> P_AN_DC P_FM1_PWM P_LED_COM3 P_LED_COM2 P_FM2_PWM 3 I C191 D191 PS2561L-1-V 1SS355 2 P_AN_PS P_AN_TH P_SW_TR I AL P_SW_MODE P_SW_SEL 1 R189 10k <1/10W> R197 10k <1/10W> CN19 B03B-XAKK-1-A 1 P_AN_TP 4 3 P_AN_TT2 P_LED_COM1 I C182 PS2561L-1-V P_AN_TC P_AN_TH R188 10k <1/10W> I C181 PS2561L-1-V P_AN_TC P_AN_TD R180, R182, R184, R186 R181, R183, R185, R187 1.0k <1/10W> 3 x8 2 P_AN_TT2 EX. I N 5V C42 - C49 0.01 x 8 SW1 CES-0402MC CN18 B03B-XASK-1-A JM181 D181 WHITE 0R0 1SS355 1 P_AN_TA P_AN_TS P_D I PSW1 P_D I PSW2 P_D I PSW3 4 P_AN_TA P_AN_TT Q36 DTC143EUA 12V R196, R195 10k <1/10W> x2 3 2 P_SRV2 Q182 DTC143EUA 3 1 R191 10k <1/10W> R192 10k <1/10W> C191 0.1 C192 0.1 1 Q192 DTC143EUA 11 P_SW_MODE P_4WV_AC P_PFC_S I P_FM1_I N R194, R193 10k <1/10W> x 2 2 Q191 DTC143EUA 1 C13 C3 0.1 220/ 16V R15 C38, C39 47 1000p x2 <1/10W> C7 330/ 15V-2 35V G 2 O 3 C14 0.1 R83 10k <1/10W> 1 P_FM2_I N C84 0.01 5V P_DEMAND1 RES MODE P_DEMAND2 50 P00 VCC 10 51 P01 VCC 62 52 P02 P33 1 + P_E2P_CS 53 P03 P34 2 P_EPV_D 54 P04 P35 64 P_E2P_SK 57 P05 P36 44 P_PR 58 P06 P37 63 P07 P43 4 P_EPV_C 49 P10 P44 5 P_EPV_B 48 P11 P45 36 47 P12 P46 9 2 P13 P47 7 27 P14 P50 15 26 P15 P51 14 P_D I PSW3 25 P16 P52 13 P_D I PSW2 24 P17 P53 12 23 P20 P54 11 22 P21 P60 35 21 P22 P61 56 20 P23 P62 55 19 P24 P63 41 18 P25 P64 40 17 P26 P65 39 1 340V 2 5 6 15V-2 R74 2.2k I C70 <1/10W> 5V PS2561L-1-V 4 1 2 15V-2 R72, R73 1.0k<1/10W> x2 C71 C75 1000p Q70 DTC143EUA 4 1 3 2 P_PFC_SO 3 P_TSO2 RESET P66 37 P67 38 42 P31 P80 34 45 P32 P81 33 P_LED1 61 VREF P82 32 P_LED2 P83 31 P_TSO R67 1.0k <1/10W> R68 100k <1/10W> I C61 BU4842F 3 NC 4 GND P_TS I I C63 S-93C66 P_LED3 MODE P84 30 P_SW_PUMP 8 GND P85 29 P_SW_ENTR 59 GND P86 28 P_SW_SEL P.F.C. PCB 6 7 8 9 5V R60 4.7k <1/10W> 1 2 P_E2P_CS P_E2P_SK P_E2P_D I R66 1.0k <1/10W> 1 CS 2 SK 3 DI 7 NC VCC DO TEST GND R64 10k <1/10W> 5V 8 4 6 5 C61 0.1 P_TSO 4 CN6 B06B-PASK-1 WHITE FLASH 5 6 5V C60 0.1 VDD 2 OUT 1 P_V2 3 5 12V C92 0.1 P_TS I C67 0.01 P_PFC_SO P30 WHITE 3 4 MODE 5V P27 CN9 1971032-9 2 3 P_PFC_SK 16 7 1 P_EPV_A P_TS I 2 INVERTER PCB 5 6 8 1 R62, R61 10k <1/10W> x2 WHITE 4 C72 0.1 2 Q90 DTC143EUA P_D I PSW1 3 CN7 1971032-8 2 12V 3 D 2 1 1 A 1 3 Q91 DTC143EUA 0.1 R92, R93 15V-3 1.0k <1/10W> x2 C91 0.1 C95 1000p R94 2.2k I C90 <1/10W> 5VPS2561L-1-V R96 1.0k <1/10W> R63 10k <1/10W> DC FAN MOTOR 2 4 2 C93 0.01 BLACK 3 3 3 R95 1.0k <1/10W> CN82 B6P-VH-B-C 1 + 2 R76 1.0k <1/10W> P_PFC_SK P_SW_TR I AL 43 *RST P_PFC_S I X1 8.00MHz 46 D84 1 DAN217U 15V-3 P_FM2_I N 3 5V P_TSO2 P_E2P_D I 60 6 5V + C66 4.7/ 50V R87 10k <1/10W> C73 0.01 5 C85 0.1 C83 R86 4.7/ 22k 50V <1/10W> 5V R75 1.0k <1/10W> P_TS I 2 DC FAN MOTOR 1 4 L81 BL02Rn1 R88 1.0k <1/10W> R9 10k <1/10W> WHITE 3 6 15V R85 33k <1/10W> 3 P_FM1=PWM P_FM1_I N P_FM2_PWM 2 D86 PTZ24B 2 2 C62, C63 C64 0.1 4.7/ x2 50V 2 CN81 B6P-VH-B 1 3 3 A R16 C40, C41 47 1000p x2 <1/10W> C9 330/ 15V-3 35V + 1 340V R82 22k <1/10W> Q83 15V DTA143EUA 1 Q82 DTC143EUA C82 0.1 C80 + 4.7/ 50V 5V R84 D83 1.0k DAN217U <1/10W> C81 0.01 + C4 100/ 16V R7 10k <1/10W> + D7 D1FL20U P_LED_COM2 R65 10k <1/10W> NC 1 I D85 PTZ24B R81 33k 3 <1/10W> 1 5V 1 D4 I C7 1SS355 BA17805 5V + C2 470/ 25V 3 L80 BL02Rn1 15V 2 2 R2 10k <1/10W> + D3 D1FL20U IC1 R5F212AASNA79FP P_AN_TP R45 - R49, R42 - R44 1.0k <1/10W> x 8 R14 C36 C37 Q80 DTC143EUA D P_SW_ENTR P_SW_PUMP 5 6 7 8 14 15 16 2200p x 6 15V D1 D1FL20U C1 330/ R13 C34 C35 35V + 12V D2 D1FL20U D9 D1FL20U Q35 DTC143EUA 2 1 R142 - R149 10k <1/10W> x8 3 2 1 3 12V P_POWER D33 - D39 SLR-325DC RED 2 11 12 13 Q34 DTC143EUA SW2 - SW6 KSM8WBTS x5 R161 10k <1/10W> R163 10k <1/10W> R126 38.3k <1/10W> 1% 1 1 6 5 4 P_LED_COM1 5V R32 1.0k <1/10W> x 6 2 2 GREEN R31 5V D161 DAN217U 1 R56 1.0k <1/10W> 9 10 3 SLR-32MC C31 0.1 CN16 1871843-3 1 2 12V I C3 uLN2003 4 5V Q31 DTA143EUA 3 + C6 47/ 35V 1 5 4 3 2 1 7 I C2 TOP254 C12 0.1 15V 47 <1/10W> x 3 R12 C32 C33 S 8 S 7 S 6 S 5 2 C C151 0.1 R156 1.0k <1/10W> Q81 DTA143EUA D8 UF4005 1 M R11 47 <1/10W> 12V HYIC1 H U 2 0 01 R 3 R8 0R0 4 D D6 1SS355 GREEN W4 SERIAL P_AN_DC T1 I H024 R3 - R6 1.0M <1/3W> 1% x4 D10 UDZS8.2B B 2 3 15V C107 0.22 VA4 470V SA2 RA-302M WHITE L102 SS11V05230 FH4 FH3 F3 10A 250V VA5 470V W3 N FH6 1 R151 - R153 220k <1/3W> 1% x3 R1 C5 340V 150k 2200p <2W> PFC5000-0702F x 2 D151 DAN217U R103 - R107 220k <1/3W> x5 GREEN PFC5000-0702F x 2 340V 1 C104 0.01 C101 VA1 0.22 470V SA1 RA-302M W5 EARTH 3 3 P I N 101 D101 LL25XB60 R101 ZPR0RCH400 BLUE PFC5000-0702F x 2 CN101 B3P5-VH-B P_EPV_D P_EPV_C P_EPV_A P_EPV_B I C17 1.5k <1/10W> x 4 TD62064 R174 3 I1 O1 2 O2 7 6 I2 R173 O3 9 11 I 3 R171 14 I 4 O4 16 R172 1 COM1GND1 4 12V 8 COM2GND2 5 C17 10 NC1 GND3 12 0.1 15 NC2 GND4 13 12V 1 2 3 4 5 6 CN17 B6B-XARK-1-A RED EXPANSION VALVE COIL OUTDOOR UNIT TRANSISTOR PCB K11CA-1200HUE-TR1 TM802 YELLOW P IN D908 US1J TM803 R900 10 <2.8W> RGDU7M DC + P I N800 BLUE R902 10 <7W> RGGS7 N IN P I N801 DC - 12V ORANGE 4 3 1 2 TM801 ORANGE D860 DAN217U 1 3 D835 DAN217U 2 3 Q836 2SC2411K C860 0.1 R885 5.6k <1/10W> 1% R886 10k <1/10W> R896 10k <1/10W> 3 P_DC2 R895 5.6k <1/10W> 1% 15V C870 0.1 I C820 NJM7812 EEPROM R834 1.0k <1/10W> R807 1.0k <1/10W> 3 12V O 3 G 2 C819 C820 47/ + 0.1 35V 1 C822 + 100/ 25V C821 0.1 2 CN801 1971032-8 ( G I C2.0-8P ) WHITE 1 2 2 5 7 8 R822 2.2k <1/10W> C827 1000p 1 4 2 3 1 3 CN803 1-1971032-2 ( G I C2.0-2P ) 1 THERMISTOR ( HEATSINK TEMP. ) L830 5V BL02Rn1 1 2 3 4 2 5V R824 1.0k <1/10W> C831 0.1 R838 10k <1/10W> CT P_CT 1 5V R852 10k <1/10W> P_PR C805 + 4.7/ 50V 3 R833 10k <1/10W> R832 1.5k <1/10W> 1% 5V C808 0.1 THERMISTOR P_TH_HT 2 13 10 C809 0.1 C940 0.022 12 R932 - R937 330 <1/10W> x 6 15V 1 14 13 12 11 24 10 8 27 48 62 61 P03 P04 P05 P06 P10 REGC GND EGND EGND AGND0 AGND1 P30 P31 P32 P33 P40 P41 P42 P43 P44 X1 X2 C800, C801 C802 C803, C804 0.1 0.1 4.7/ x2 x2 50V 9 26 47 63 60 64 59 23 22 21 20 19 18 54 53 52 51 50 49 46 45 44 43 42 41 40 39 38 37 36 6 7 + MICON 2 1 3 R848 4.7k <1/10W> R847 1.0k <1/10W> 7 - + 6 5 R845, R846 22k <1/10W> 1% x 2 C942 0.01 TM804 U RED V 38 TM805 V WHITE W 37 TM806 W BLACK NU 36 3 4 4 3 NV 35 CT800, CT801 FC-1-X x 2 NW 34 2 1 1 2 5V P_C I N R955 100 <1/4W> R954 1.0k <1/10W> R841 10k <1/10W> 1% R842 10k <1/10W> 1% R840 100 <1/10W> 1% 5V 5V I C840-2 BA2904F R843, R844 22k <1/10W> 1% x 2 5V D850 DAN217U +C810 4.7/ 50V D851 DAN217U 2 1 3 C853 1000p P_UP P_UN P_VP P_VN P_WP P_WN R868 4.7k <1/10W> R867 1.0k <1/10W> 1 1 8 I C840-3 BA2904F RXDA0 TXDA0 P_S I 1 P_SO1 VCC G/V 4 - + 2 3 R865, R866 22k <1/10W> 1% x 2 R861 10k <1/10W> 1% R862 10k <1/10W> 1% 5V C855 0.1 R990 4.7k <1/10W> C 3 5V R800, R801 10k <1/10W> x 2 P_JM2 P_JM1 FLASH 12 C941 1000p R951 4.7k <1/10W> R952 1.0k <1/10W> 5V I C961-1 BA2903F 1 - 2 + A 2 C963 4.7/ 50V R969, R970 560 <1/10W> x2 + - 6 + 5 15V 1 R968 0R0 I C960-3 BA3472F VCC G/V 4 R964 1.8k <1/10W> 1% C968 1000p 3 8 C960 0.1 R966 15k <1/10W> 1% 5V REF 1 I C962 TL431A I C962 0.1 VCC G/V 4 15V C969 1000p OVER CURRENT TRIP I C961-3 BA2903F 5V P_M I 7 15V C857 0.1 C858 + 4.7/ 50V I C960-2 BA3472F - 6 + 5 8 R863, R864 22k <1/10W> 1% x 2 5V SHUNT CURRENT DETECT THIS FUNCTION IS DELETED X800 2.5MHz 7 5V 15V + C856 4.7/ 50V I C961-2 BA2903F R860 100 <1/10W> 1% I C840-1 BA2904F PHASE V CURRENT DETECT HS 15V 2 3 5V P_I V 2 R953 10k <1/10W> PHASE U CURRENT DETECT P_LED1 1 3 5V D841 DAN217U C843 1000p VCC EVCC EVCC AVCC0 AVCC1 AVRF0 AVRF1 P11 P12 P13 P14 P16 P17 P20 P21 P22 P23 P24 P25 P26 P27 U 39 P_VOT C926 - C931 470p x 6 P_I U RST* AN I 00 AN I 01 AN I 02 AN I 03 AN I 10 AN I 11 AN I 12 AN I 13 FLMD0 PDL0 PDL1 PDL2 PDL3 PDL4 PDL5 PDL6 PDL7 P00 P01 P02 P 40 P_TR C806 0.1 5 1 2 3 4 58 57 56 55 25 35 34 33 32 31 30 29 28 17 16 15 UP VP1 VUFB VUFS VP VP1 VVFB VVFS WP VP1 VPC VWFB VWFS UN VN WN CFO FO VOT VN1 VNC CIN VSC 1 3 4 6 7 9 10 12 13 14 15 16 18 27 28 29 25 26 23 21 22 24 19 C904 C905 220/ 1.0 + 35V 8 P_C I N TXDA0 R851, R853, R855 10k <1/10W> x 3 I C921-6 11 12 C920 - C925 1000p x 6 R920 - R925 10k <1/10W> x 6 RXDA0 HS I C921-1 9 4 1 FLMD0 R857, R859 0R0 x 2 I C921-5 13 6 3 RST_OUT 5 I C921-2 2 D840 DAN217U 3 C833 0.1 6 2012.03.06 P_TR R815 10k <1/10W> 2 I C921-4 1 2 I C800 uPD70F3713 P_DC P_TH_HT P_I U P_CT P_M I P_DC2 FLMD0 P_JM1 P_JM2 P_E2P_CS P_E2P_SK P_E2P_D I R814, R816 10k <1/10W> x2 5V D832 DAN217U 5V 2 VDD NC 3 1 OUT GND 4 P_I V C828 0.01 I C920-6 I C921-3 10 5V R813 10k <1/10W> R802 4.7k <1/10W> 11 I C920-1 5 I C801 BU4842F P_SO1 Q820 DTC143EUA 1 C834 0.1 5V WHITE FLASH D830 DAN217U R830 100k <1/10W> 2 CN800 B06B-PASK-1-A R812 1.0k <1/10W> 3 R831 10k <1/10W> 2 P_VOT RED RST_OUT P_S I 1 3 1 2 C826 100/ + 25V R823 1.0k <1/10W> BLUE CT I N C825 0.1 MAIN PCB COM. 5V R820, R821 1.0k <1/10W> x 2 CN802 2-1871843-3 ( G I C2.5-3P ) O 3 I C822 PS2561L-1-V 4 6 G C818 C823 +C824 330/ 0.1 0.1 35V 3 MAIN PCB C807 0.01 5V 1 I R804 100k <1/10W> R805 0R0 4 D912 STTH112 D913 - D915 PTZ24B x3 8 74HC14 x 12 8 4 6 5 CS VCC SK DO D I TEST NC GND I C920-5 9 I C900 PS22A76 D911 STTH112 R806 10k <1/10W> P_LED1 Q835 DTC143EUA D821 1SS355 I C821 NJM7805 1 2 3 7 P_E2P_CS P_E2P_SK P_E2P_D I R835 1.0k <1/10W> D820 1SS355 1 I I C802 S-93C56B I C920-2 6 3 R926 - R931 1.0k <1/10W> x 6 D831 SLR-325 I C920-4 5 P_UP P_VP P_WP P_UN P_VN P_WN 15V LED I C920-3 D901 PTZ24B C901 - C903 1.0 x3 C910 - C912 R911 - R913 220/35V 330k <1/10W> x3 x3 D910 STTH112 IPM P_DC P_PR C913 - C915 1.0 x3 R910 39 <1/2W> C933 0.1 1 DC VOLTAGE DETECT 2 5V 1 C932 0.1 3 R836 4.7k <1/10W> R890 - R894 220k <1/3W> 1% x 5 C934 + 4.7/ 50V DC VOLTAGE DETECT R837 4.7k <1/10W> 2 1 2 R940 - R949 0.1 <1W> 1% x 10 5V 5V 2 D870 DAN217U 15V R880 - R884 220k <1/3W> 1% x 5 P OUT R828, R829 0R0 x 2 L870 L960 BL02Rn1 L900 BL02Rn1 K880 G4AN-1A W800 B DC+ I N R901 10 <7W> RGGS7 - + 2 3 I C960-1 BA3472F R962 15k <1/10W> 1% 5V C964 1000p R960 1.8k <1/10W> 1% OUTDOOR UNIT ACTIVE FILTER PCB - 1 K-11BZ-1100HUE-AF0 REACTOR L1 - L3 12A 18mH x3 2 3 R300 100 R306 10k 1% 5V 6 5 C303 0.1 - 7 + I C300-2 BA2902F 5V C306 100p R315 2.2k R330 47k 1% 5V R333 22k C305 + 4.7/ 50V C300 0.1 R304 10k 1% 5V R301 100 1% 1 9 10 - D333 RB751V 8 + R310 47k 1% VR301 B2K 1 3 R307 10k C304 0.1 C307 100p 2 3 - + I C300-1 BA2902F 1 R316 2.2k I C330-3 BA2902F 15V 13 12 R337 47k 1% D331 RB751V 6 5 R323 47k 1% R320, R321 47k 1% x 2 5V R322 22k 13 12 - + 14 I C300-4 BA2902F C320 R326 0.1 2.2k - 7 + 5V R328 10k R332 47k 1% R338 47k 1% D332 RB751V 9 10 + 8 I C330-1 BA2902F R347 47k 1% VAC_L3 VAC_L2 VAC_L1 P_CURRCON_PWM / M34P C360 0.01 R350 22k 13 12 5V R364 22k C362 0.1 - + - + 7 I C331-2 BA2902F 5V 6 7 + 14 C385 1000p R370 47 3 C365 0.1 R365 39k 1% R366 22k R367 100k R398, R399 10k 1% x 2 I C580-3 BA2901F I C580-2 BA2901F I C580-1 BA2901F C584 0.1 8 9 + 14 I C380-1 BA2901F 4 2 C389 0.1 5 6 7 + 1 4 5 + 2 C380 0.1 R418 1.0k C381 0.1 12 13 2 1 3 13 4 5 6 9 10 I C411-3 HC08 2 1 3 I C412-1 HC08 9 10 8 12 13 11 C415, C418, C421 100p x 3 34 NW 35 NV 36 NU 37 W 38 V R440 1.0k 2 R602 1.0k R601 10k P_ERR_RESET / M05P R603 1.0k C602 100p 5V C580 0.1 U R448 0R0 I C412-4 HC08 1 3 5V C601 5V 100p C600 0.1 39 40 R447 0R0 5V R412, R415 10k x 2 5V R600 10k 15V P R446 0R0 8 3 5V R583 8.2k 1% R584 2.2k 1% UP VP1 VUFB VUFS VP VP1 VVFB VVFS WP VP1 VPC VWFB VWFS UN VN WN CFO FO VOT VN1 VNC CIN VSC I C450 PS22A76 1 3 4 6 7 9 10 12 13 14 15 16 18 27 28 29 25 26 23 21 22 24 19 11 C414, C417, C420 100p x 3 I C411-2 HC08 6 C461 0.1 11 I C412-3 HC08 4 5 C463 0.1 R443 0R0 8 I C412-2 HC08 R421, R424 1.0k x 2 11 + + 9 10 R445 0R0 I C381-4 BA2901F 10 - 13 15V I C410-3 HC08 10k x 2 C413, C416, C419 I C410-4 R417 100p I C410-1 HC08 HC08 12 1.0k x3 R411, R414 10k x 2 I C380-1 BA2901F 3 C460 0.1 R444 0R0 R420, R423 1.0k x 2 2 2 1 C462 0.1 2 I C331-1 BA2902F 1 - 2 3 I C381-2 BA2901F R402 1.0k 4 5 + + R394 100k 1% R382 R385 1.0k 4.7k R582 2.2k 1 6 I C411-1 HC08 R413 R401 1.0k R397 1.0k 1% I C380-2 BA2901F 6 1 7 C581 - C583 1000p x3 Q370 2SA1037AK 2 6 5 14 C464 0.022 I C411-4 HC08 5V I C331-4 BA2902F R361 - R363 47k 1% x 3 C361 0.01 8 9 + R396 1.0k 1% R410 4 5 N OUT R454 100 <1/4W> D457 PTZ24B C412 0.1 I C410-2 HC08 R419, R422 1.0k x 2 I C381-3 BA2901F R393 100k 1% R388 10k R391 3.9k 1% R581 2.2k C338 0.1 C363 0.01 I C380-3 BA2901F + 5V 5V C411 0.1 R416 1.0k 14 5V R387 10k R390 3.9k 1% R580 2.2k 1 R360 47k 1% 1 + 15V 5V C331 0.1 - + R353 R356 47k 47k 1% 1% D335 RB751V R329 10k I C331-3 BA2902F 15V R368 47k P_I NTE_RESET / M13P 2 3 R400 1.0k 8 9 + R392 100k 1% R380 R383 1.0k 4.7k C410 0.1 5V R395 1.0k 1% I C380-4 BA2901F 10 13 R381 R384 1.0k 4.7k R349 22k C337 0.1 R344 47k 1% C335 0.1 C382 0.1 C384 1000p R346 47k 1% D334 RB751V R341 47k 1% R335 5V 10k C377 + 4.7/ 50V C379 + 4.7/ 50V R386 10k R389 3.9k 1% R352 R355 47k 47k 1% 1% I C330-2 BA2902F 2012.02.29 14 + C454 + 100/ 35V 5V C383 1000p R331 47k 1% D353 STTH112 P_ARMU_R / M06P P_ARMD_R / M09P P_ARMU_S / M07P P_ARMD_S / M10P 11 R343 47k 1% C334 0.1 Jump To Page2 - + I C330-4 BA2902F C336 0.1 R340 47k 1% R334 5V 22k P_AVECURR / M26P L380 5V BL02Rn1 R348 5V 22k R327 10k R358 47k P_ARMU_T / M08P P_ARMD_T / M11P R345 47k 1% 2 3 2 D330 RB751V R357 22k C357 + C358 47/ 0.1 35V C330 0.1 15V D301 DAN217U R351 R354 47k 47k 1% 1% R336 47k 1% C333 0.1 15V + C302 4.7/ 50V C301 0.1 R342 47k 1% TM505 9 10 R606 10k I C600-2 74HC00 5 4 1 3 12 13 6 2 11 I C600-4 74HC00 2 1 3 I C600-1 74HC00 R605 1.0k R604 10k Q440 - Q445 DTC143EUA x 6 1 3 2 1 3 2 P_ERR_PFC / M04P C603 1000p 1 3 2 1 R441 2.2k P_PLSCOUNT / M16P C440 1000p 8 I C600-3 74HC00 PFC_ERROR VDC_P R339 47k 1% R309 47k 1% R453 R303 10k VR300 B2K 1% 1 + 0.1 x 3 R450 D352 39 STTH112 <1/2W> PTZ TE25 24B x 4 L450 BL02Rn1 2 3 C457 1 1 330k x 3 2 47/35V x 3 1 C451 2 D351 STTH112 15V D300 DAN217U R451 CT301, CT300 FC-1-X x 2 15V C452 4 C458 3 TM502 R452 4 TM501 TM302 C453 3 TM301 TM504 DC+ OUT C459 L3 I N W302 TM500 R454 L2 I N W301 TM300 R455 L1 I N W300 R456 From Filter PCB Jump To Page2 + C364 0.1 13 OUTDOOR UNIT ACTIVE FILTER PCB - 2 K11BZ-1100HUE-AF0 Jump To Page1 D470 DAN217U 2 R503 8.2k 1% C476 1000p R485 - R489 220k <1/3W> 1% x 5 I C470-3 BA2902F 9 10 + 15V I C470-2 BA2902F 6 5 1 D473 DAN217U 2 3 + R502 5V 8.2k 1% 2 R507 2.2k TO MAIN PCB O G - 12 3 I C630 NJM7805 2 C632 0.1 C634 C630 + C631 0.1 0.1 330/ 35V 8 R635 2.2k 9 C635 1000p R639, R637 1.0k x 2 R636 2.2k 1 4 2 3 R529 10k R513 5V 2.2k 5V 5V C472 0.1 5V R652 10k 5V C636 1000p 15V 1 4 2 3 VDD 2 3 NC 4 GND OUT 1 I C655 BU4842F 3 R511 2.2k I C510-4 BA2901F 10 13 11 C514 1000p C517 0.1 R656 0R0 C646 0.01 C519 1000p R523 1.0k C520 1000p I C510-2 BA2901F 6 1 7 R524 1.0k + C637 0.01 C521 1000p C518 0.1 P_ARMU_R / M06P P_ARMU_S / M07P P_ARMU_T / M08P P_ARMD_R / M09P P_ARMD_S / M10P P_ARMD_T / M11P P_ZERO_S / M12P R569, R568, R567, R566, R565 22k <1/3W> 1% x 5 I C300-3 BA2902F 2 1 15V 5V 3 D561 DAN217U C560 1000p 5V R570 5.6k 1% C562 0.1 C593 0.1 R595 2.2k 1% P_ZERO_R / M14P R575 47k P_AD_VDC / M27P C575 0.1 P_ZERO_S / M12P 5V R660 - R662 10k x 3 TEST JP / M01P P_MODEL SW1 / M02P P_MODEL SW2 / M03P P_ZERO_T / M13P P_SD I / M21P P_ZERO_T / M13P P_ZERO_R / M14P R659 10k 5V P_RESET / M40P R657 1.0k C611 0.1 P_RXD / M18P P_TXD / M19P P_SDO / M20P P_SD I / M21P P_SDCLK / M22P D670 SLR-325 RED R670 1.0k 5V P31 P30 P17 P16 P15 P14 P13 P12 P11 P10 AVDD AVSS 13 14 15 16 17 18 19 20 21 22 23 24 I C610 uPD78F0514 48 47 46 45 44 43 42 41 40 39 38 37 VDD VSS C X1 X2 MD0 P123 P124 *RST P40 P41 P120 C610 0.1 C612 1.0 1 2 P_FLMD0 / M43P P_TXD / M19P 14 R671 1.0k + C613 4.7/ 50V 3 P_RESET / M40P P_I NTE_RESET / M13P P_LED1 / M36P P_CURRCON_PWM / M34P P_AD_VDC / M27P P_AVECURR / M26P P_PEAK_VAC / M25P R650, R651 10k x 2 2012.02.29 R572 1.0k - 9 + 10 15V P_RXD / M18P 6 C592 1000p 8 P_ERR_RESET / M05P P_ERR_PFC / M04P P_MODEL SW2 / M03P P_MODEL SW1 / M02P TEST JP / M01P P_FLMD0 / M43P 5 - 5V R593 10k R564, R563, R562, R561, R560 22k <1/3W> 1% x 5 P_SDO / M20P P_SDCLK / M22P C638 0.01 11 10 + 1 3 R521 1.0k 5V C515 1000p R646 1.0k I C580-4 BA2901F 13 R520 1.0k 5V P_PLSCOUNT / M16P R655 100k + C516 0.1 R514 2.2k R512 2.2k R645 1.0k R643, R644 1.0k x 2 R522 1.0k 5V R515 2.2k 5V C645 0.1 I C510-1 BA2901F - 4 5 + C510 0.1 Q640 DTC143EUA 1 P_PEAK_VAC / M25P C551 0.1 R519 1.0k 5V C513 1000p 5V I C636 PS2561L-1-V R640, R638 1.0k x 2 4 I C530-1 BA2902F D535 RB751V C550 + 47/ 35V R594 8.2k 1% R508 2.2k 2 7 FLASH 1 I C530-4 BA2902F R544 1.0k 15V 2 R571 5.6k 1% C561 1000p R551 47k R550 22k 14 D560 DAN217U R541 47k 1% C633 + 100/ 25V I C635 PS2561L-1-V 6 2 C536 0.1 3 5 1 2 3 + 13 12 + R510 2.2k C475 1000p 4 WHITE 5V R542 22k R528 10k 1 C470 0.1 14 + 3 CN650 B06B-PASK R543 47k 1% C537 100p C590 0.1 12 11 10 9 8 7 6 5 4 3 2 1 WHITE 2 13 D630 1SS355 1 I CN630 1971032-9 ( G I C2.0-9P ) R540 47k 1% R592 5.6k 1% 14 C591 1000p R591 2.2k 1% 3 I C470-4 BA2902F 1 5V R535 22k C535 0.1 15V 15V I C530-3 BA2902F D532 RB751V R505 8.2k 1% C478 1000p I C470-1 BA2902F 1 7 2 3 8 D534 RB751V 8 9 + 5V R527 10k R532, R538 47k 1% x 2 D472 DAN217U 15V 9 10 + C534 0.1 C474 1000p R501 5V 8.2k 1% R495 - R499 220k <1/3W> 1% x 5 - + I C530-2 BA2902F D531 RB751V 5V R534 22k R504 8.2k 1% C477 1000p 3 R480 - R484 220k <1/3W> 1% x 5 R506 2.2k 2 R475 - R479 220k <1/3W> 1% x 5 7 I C510-3 BA2901F R590 10k R531, R537 47k 1% x 2 8 D471 DAN217U 1 R490 - R494 220k <1/3W> 1% x 5 C533 0.1 C473 1000p R500 5V 8.2k 1% 6 5 + D533 RB751V C530 0.1 P32 P70 P71 P72 P73 P74 P75 P33 P63 P62 P61 P60 3 15V 5V R533 22k R539 47k 1% 25 26 27 28 29 30 31 32 33 34 35 36 1 R470 - R474 220k <1/3W> 1% x 5 15V D530 RB751V P27 P26 P25 P24 P23 P22 P21 P20 P130 P01 P00 P140 15V PFC_ERROR VDC_P VAC_L3 VAC_L2 VAC_L1 Jump To Page1 R530, R536 47k 1% x 2 P_LED1 / M35P X610 8.00MHz 2 Q670 DTC143EUA 3 1 OUTDOOR UNIT FILTER PCB K07AQ-0700HUE-FL0 3 Phase 380 - 415V 50Hz L1 I N TM200 RED L2 I N TM201 WHITE L3 I N TM202 BLACK VA202 820V H-0017-2 x 2 FH200 FH201 P201 15A H-0017-2 x 2 FH204 FH205 P202 15A W206 L201 RC3V3812-009PF05 12A 0.9mH TM203 L1 OUT RED VA200 P200 820V 15A H-0017-2 x 2 FH202 FH203 VA201 820V 5 6 5 6 3 4 3 4 1 2 1 2 TM204 L2 OUT WHITE TM205 L3 OUT BLACK VA203 470V SA200 RA-362M E L200 RC3V3812-009PF05 12A 0.9mH R200 - R202 1.0M <1/2W> x3 C206 - C208 0.022 x3 C200 - C202 1.0 x3 C218 - C220 1.0 x3 GREEN 3 4 CT200 FC-1-X 2 1 1SS133 x 4 D200 D202 C221 + 220/ 16V D201 2012.02.29 15 D203 VR200 B200 R203 470 <1/4W> CN200 2-1871843-3 ( G I C2.5-3P ) BLUE 1 3 2 1 2 3 CT OUT OUTDOOR UNIT CAPACITOR PCB K07AP-0700HUE-P0 W700 W702 P IN P OUT ORANGE YELLOW R700 68K R702 68K + C700 660/ 450V R701 68K R703 68K C701 + 660/ 450V + C703 660/ 450V W703 W701 2012.02.29 + C702 660/ 450V N IN N OUT PURPLE BLUE 16 ER R OR D ETEC TION INDOOR UNIT and WIRED REMOTE CONTROL If you use a wireless remote control, the lamp on the photo detector unit will output error codes by way of blinking patterns. If you use a wired type remote control, error codes will appear on the remote control display. See the lamp blinking patterns and error codes in the table. An error display is displayed only during running. Indoor unit display Troubleshooting at the display is possible either . on the wired or wireless remote control. ECONOMY Lamp (green) TIMER Lamp (orange) OPERATION Lamp (green) Remote control This is possible only on a wired remote control. If an error occurs, the following display will be shown. (“Er” will appear in the set room temperature display.) Error code Unit number of indoor unit Indoor unit OPERATION TIMER lamp lamp (green) (orange) ( ) : Number of flashing 2012.07.25 Indoor unit Description OPERATION TIMER lamp lamp (green) (orange) ECONOMY lamp (green) Wired remote control Description Discharge temp. sensor error (1) Serial communication error (7) (1) (1) (2) Wired remote control communication error (7) (2) (1) (5) Check run unfinished (7) (3) (2) (1) (7) (4) Outdoor temp. sensor error (2) (2) Indoor unit capacity error (7) (5) Suction Gas temp. sensor error (2) (3) Combination error (7) (6) • Connection R.C. address error (7) (7) • Connection R.C. address error (8) (2) (8) (3) (8) (4) (8) (6) (2) (4) R.C. address or Refrigerant circuit address setting error [Simultaneous Multi] (indoor secondary unit) [Simultaneous Multi] (indoor unit or branch unit) [Flexible Multi] Primary unit, secondary unit set-up error [Simultaneous Multi] (2) (7) (3) (1) Power supply interruption error (3) (2) (3) (5) Indoor unit PCB model information error Manual auto switch error (4) (1) (4) (2) (5) (1) (5) (3) (5) (7) (5) (15) (6) (6) : 0.1s on / 0.1s off Wired remote control (1) EX. Self-diagnosis : 0.5s on / 0.5s off ECONOMY lamp (green) (6) (6) (6) • 2-way valve temp. sensor error • 3-way valve temp. sensor error Heat sink temp. sensor error • Sub-cool Heat Ex. gas inlet temp. sensor error • Sub-cool Heat Ex. gas outlet temp.sensor error Liquid pipe temp. sensor error Current sensor error • Discharge pressure sensor error • Suction pressure sensor error • High pressure switch error Trip detection (9) (4) Indoor unit Heat Ex. Middle temp. sensor error (9) (5) Indoor unit fan motor error (9) (7) Drain pump error (9) (8) Outdoor unit fan motor 2 error Damper error (9) (9) 4-way valve error Indoor unit error (9) (10) Coil (expansion valve) error (10) (1) (10) (3) (10) (4) (10) (5) (13) (2) (2) (3) Inverter error (4) Active filter error, PFC circuit error (10) Outdoor unit Heat Ex. liquid temp. sensor error Room temp. sensor error Outdoor unit main PCB model information error or communication error (5) Compressor temp. sensor error Trip terminal L error Display PCB microcomputers communication error 17 Compressor rotor position detection error (permanent stop) Outdoor unit fan motor 1 error Discharge temp. error Compressor temp. error High pressure error Low pressure error Branch boxes error [Flexible Multi] OUTDOOR UNIT TEST RUN CAUTION Always turn on the power 6 hours prior to the start of the operation in order to protect the compressor. 1. Check items before performing the test run 2.1. Operating procedures for the test run Make sure to perform the test run. Before performing the test run, be sure to check the following points. (1) Check the 3-way valves (both at the liquid side and gas side) are opened. (2) Set the operation mode to “COOL” or “HEAT”. (1) Is gas leaking? Check connection of each pipe (flare connection part, brazing part). POWER MODE ERROR (2) Is a breaker installed to the power cable of the outdoor unit ? (3) Has each cable been securely connected to the terminal according to the specifications ? TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) In the first test run, be sure to set the operation mode to “COOL”. The operation mode cannot be switched between “COOL” and “HEAT” during the test run. To switch the operation mode between “COOL” and “HEAT”, stop the test run, switch the operation mode, and then start the test run again. (4) Are the 3-way valves (gas pipes and liquid pipes) of the outdoor units open? (5) Has the power been supplied to the unit for at least 6 hours ? (6) Has the necessary local setting been done ? (7) Check insulation resistance of 1 M or more using a 500V mega tester. If no problems are found with the above items, perform the test run according to “Test run method”. If any problems are found, immediately resolve the problem and re-check the items. (3) Press [ENTER] (TEST RUN) switch for more than 3 seconds. POWER MODE 2. Test run method ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) “TEST RUN” LED will light on. If the compressor is operating at starting the test run, the compressor will stop and, after a while, the test run will start. Either of the above "LOW NOISE" or "PEAK CUT" will light on during the test run if local setting function is selected. CAUTION If the test run is performed for 1 outdoor unit in a group control system installation, the test run will also be performed for the other units. Therefore, make sure that all of the units have been installed before starting a test run. (Group control system installation described in “SPECIAL INSTALLATION METHODS” in the installation manual of the indoor unit.) (4) Confirm operating status. (5) Press [ENTER] (TEST RUN) switch again. POWER Operate [ENTER] (TEST RUN) switch on the display board by the following procedure. MODE ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) “TEST RUN” LED lights off, and TEST RUN stops. LED display part Test run will finish after about 60 minutes automatically. At the same time, “TEST RUN” LED will light off. Test run may be stopped before operating for 60 minutes if an error occurs after a starting test run. Operation mode Upper : HEAT Lower : COOL 2012.04.26 [ ENTER ] ( TEST RUN ) switch 18 OUTDOOR UNIT ERROR CODE DISPLAY Display when an error occurs POWER MODE ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) PEAK CUT (L4) (L5) (L6) (L7) Blinks (Hi-speed) Check that the ERROR LED blinks, and then short-press the [ENTER] switch once. The number of blinks of the LED indicates the type of error. Display mode Error code check table POWER : ON : OFF : Blink (0.5s ON / 0.5s OFF) ( ) : Number of flashing TEST RUN PUMP DOWN (L1) (L2) (2) (1) (1) Serial forward transmission error immediately after operation (2) (1) (1) Serial forward transmission error during operation (2) (2) (2) Indoor unit capacity error (2) (5) (15) Indoor unit error (2) (6) (1) Over voltage (2) (6) (1) Power supply frequency error (2) (6) (2) Outdoor unit PCB model information error (2) (6) (2) PFC communication error (2) (6) (3) Inverter error (2) (6) (4) PFC AD detection error (2) (6) (4) PFC hardware error (2) (6) (5) IPM error (Trip terminal L error) (2) (6) (8) Rush current limiting resister temp rise protection (2) (7) (1) Discharge temp. sensor error (2) (7) (2) Compressor temp. sensor error (2) (7) (3) Heat Ex. middle temp. sensor error (2) (7) (3) Outdoor unit Heat Ex. liquid temp. sensor error (2) (7) (4) Outdoor temp. sensor error (2) (7) (7) Heat sink temp. sensor error (2) (7) (7) PFC heat sink temp. sensor error (2) (8) (4) Current sensor 1 error (stoppage permanently) (2) (8) (6) High pressure switch 1 error (2) (8) (6) Pressure sensor error (2) (9) (4) Trip detection (stoppage permanently) (2) (9) (5) Compressor motor control error (stoppage permanently) (2) (9) (5) Compressor motor loss of synchronization (stoppage permanently) (2) (9) (7) Outdoor unit fan motor 1 error (Duty error) (2) (9) (8) Outdoor unit fan motor 2 error (Duty error) (2) (9) (9) 4-way valve error (2) (10) (1) Discharge temp. 1 error (stoppage permanently) (2) (10) (3) Compressor 1 temp. error (stoppage permanently) (2) (10) (5) Low pressure error MODE ERROR 2012.07.25 LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) 19 Description (L7) OUTDOOR UNIT PUMP DOWN (Refrigerant collecting operation) 2. Pump down procedure Perform the following procedures to collect the refrigerant when moving the indoor unit or outdoor unit (2) Turn the power on. (1) Check the 3-way valves (both at the liquid side and gas side) are opened. POWER MODE WARNING Never touch electrical components such as the terminal blocks or reactor except the switch on the display board. It may cause a serious accident such as electric shock. ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) (3) Press [PUMP DOWN] switch for 3 seconds or more after 3 minutes after power on. POWER CAUTION MODE Perform the pump down operation before disconnecting any refrigerant pipe or electric cable. ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) LED display lights on as shown in the above figure, and the fans and the compressor start operating. Collect refrigerant from the service port or the 3-way valve if pump down cannot be performed. If the [PUMP DOWN] switch is pressed while the compressor is operating, the compressor will stop, then start again in about 3 minutes. In case of a group control system installation, do not turn the power off pump down is completed in all outdoor units. (Group control system installation described in “SPECIAL INSTALLATION METHODS” in the installation manual of the indoor unit.) (4) LED display will change as shown below about 3 minutes after the compressor starts. Fully close the 3-way valve on the liquid pipe side at this stage. POWER Operate [PUMP DOWN] switch on the display board in the manner described below. MODE ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) LED display part If the valve on the liquid pipe side is not closed, the pump down cannot be performed. (5) When LED display changes as shown in the below figure, close the 3-way valve on the gas pipe side tightly. POWER MODE ERROR TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) If the valve on the gas pipe side is not closed, refrigerant may flow into the piping after the compressor stops PUMP DOWN switch Step (4) Closing direction Step (5) Closing direction Reactors Hexagon wrench Terminal blocks Liquid pipe Gas pipe (6) LED display changes after 1 minute as shown in the figure below POWER Service hose MODE Service port ERROR Charging port TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) Fans and compressor stop automatically. If the pump down is successfully completed (the above LED display is shown), the outdoor unit remains stopped until the power is turned off. Service port cap Charging port cap Service hose 3-way valve (7) Turn the power off. POWER MODE 1. Preparation for pump down TEST RUN (L1) PUMP DOWN (L2) LOW NOISE (L3) (L4) PEAK CUT (L5) (L6) (L7) PUMP DOWN is completed. (Note) To stop pump down, press the [PUMP DOWN] switch again. To start the pump down again after the compressor is automatically stopped due to an error, turn the power off and open the 3-way valves. Wait 3 minutes, turn the power on and start the pump down again. When starting the operation after completion of the pump down, turn the power off, and then open the 3-way valves. Wait 3 minutes, turn the power on and perform a test run in the “COOL” operation mode. Confirm that the power is off, and then open the service panel. 2012.04.26 ERROR 20 3 PARTS 5 4 INDOOR UNIT 7 6 10 1 2 8 9 11 13 Ref. Description 11 12 13 14 15 2012.04.09 21 Part number 1 Kit (Base Sub Assy) 9371360010 2 Panel Left Sub Assy 9360427014 3 Kit (Panel Right Assy) 9371361017 4 Top Cover 9359737018 5 Cover (Decoration) R 9359744016 6 Cover (Decoration) L 9359745013 7 Kit (Side Cover R) 9371364025 8 Kit (Side Cover L) 9371365022 9 Intake Grille 9359738015 10 Air Filter 9359739012 11 Front Panel 9359734017 12 Indicator PCB 9705891050 13 PCB Holder 9359736011 14 Receiver Cover 9359714002 15 Badge 9359735175 INDOOR UNIT Drain pan, Flap Ref. Description Part number 2 Panel Left Sub Assy 9360427014 3 Kit (Panel Right Assy) 9371361017 21 Evaporator Sub Assy (36, 45) 9360428264 21 Evaporator Sub Assy (54) 9360428301 22 Drain Pan Sub Assy 9360429032 23 Flap Assy 9359731016 24 Flap Spring 9359730002 25 Sector Gear 9359729006 26 Pinion Gear 9359728009 27 Motor Base 9359727002 28 Step Motor V 9900362010 -- Drain Cap 9358746004 -- Pipe Thermistor 9900022020 21 22 23 3 24 2 27 25 28 22 26 3 23 2012.04.09 22 INDOOR UNIT Fan motor 38 33 37 35 36 38 31 34 Ref. Description Part number 31 Fan Motor Assy 9603167011 32 Rubber 9385102002 33 Casing 9359704003 34 Kit (Cover Casing) Sub Assy 9371367019 35 Sirocco Fan Assy 9359701002 36 Joint Assy 9378038011 37 Shaft 9359707004 38 Bearing B Assy 9357921006 32 31 2012.04.09 23 49 INDOOR UNIT Louver Base Sub Assy 48 51 47 46 Ref. Description Part number 41 Louver Base Sub Assy 9360432049 42 Louver 9359719014 43 kit (Louver Base) Sub Assy 9371369013 44 Step Motor H 9900297015 45 Louver Spring 9359720003 46 Louver Link 9359726005 47 Motor Rod 9359723004 48 Louver Rod 9359725008 49 Louver Stopper 9359724001 50 Louver Insulation R 9359721000 51 Louver Insulation L 9359722007 2012.04.09 45 43 44 42 41 50 24 INDOOR UNIT Control unit 61 65 66 62 67 68 63 Ref. Description 64 2013.03.07 25 Part number 61 Main PCB (36) 9709245385 61 Main PCB (45) 9709245292 61 Main PCB (54) 9709245521 62 Power Supply PCB 9707398342 63 Terminal 3P 9703345012 64 Terminal 3P 9306489045 65 Reactor Assy 9707457018 66 Room Thermistor 9703299025 67 Remote Control 9379219037 68 Remote Control Holder 9305642045 13 1 PARTS OUTDOOR UNIT 12 8 9 11 6 14 4 10 3 7 2 5 Ref. Description Parts number Ref. Description Parts number 1 Top Panel Sub Assy 9374417032 8 Reactor Assy 9900641016 2 Front Panel Sub Assy 9374414130 9 Motor, DC Brushless 9602843046 3 Sevice Panel Sub Assy 9374415076 10 Propeller Fan Assy 9366378020 4 Emblem Rear 9351355005 11 Condenser A Sub Assy 9374420261 5 Pipe Cover Front 9378861015 12 Condenser B Sub Assy 9374422081 6 Right Panel Sub Assy 9374416219 13 Thermo Holder 9375211011 7 Base Assy 9374166220 14 Protective Net 9375381042 2012.07.25 26 21 OUTDOOR UNIT 22 28 25 24 27 29 26 30 4-way Valve Assy Ref. Description Parts number 21 Expansion Valve Coil 9900190057 22 Expansion Valve Assy 9370947182 23 Strainer Assy 9372524039 24 Solenoid 9970113024 25 4-way Valve Assy 9374425273 26 3-way Valve Assy 9379079006 27 3-way Valve Assy 9379077002 28 Sensor 9900505011 29 Accumulator Assy 9375250096 30 Compressor Sub Assy 9374423286 23 Expansion Valve Assy 2012.03.16 27 OUTDOOR UNIT 33 35 32 31 36 34 37 (yellow) (white) (connector : blue) 31 Main PCB (36) 9707627091 31 Main PCB (45) 9707627077 31 Main PCB (54) 9707627084 32 Filter PCB 9707609011 33 Active Filter PCB 9709008010 34 Capacitor PCB 9707608014 35 Transistor PCB 9709010020 36 Reactor Assy 9900481018 37 Terminal 9900428082 38 Compressor Thermistor 9900516000 39 Discharge Thermistor 9900515003 40 Thermistor (Heat Exchanger Mid) 9900513009 41 Thermistor (Heat Exchanger Out) 9900514006 42 Outdoor Thermistor 9900517007 43 Heatsink Thermistor (Inverter) 9900518011 44 Heatsink Thermistor (PFC) 9900518028 2013.03.07 38 39 40 44 43 (red) (red) 28 (white) 41 650 Parts number 200 Ref. Description (red) 42 ACCESSORIES INDOOR UNIT Name and Shape Q'ty Application Part number Drain hose insulation 1 Adhesive type 70 x 230 9360464002 VT wire 1 For fixing the drain hose L 280 mm 313806350303 Coupler heat insulator (large) 2 For indoor side pipe joint (gas pipe) 9378173569 Coupler heat insulator (small) 1 For indoor side pipe joint (liquid pipe) 9378173521 Cable tie Large 4 Small For fixing the coupler heat insulator 4 9301501001 312300787605 Special nut A (large flange) 4 For installing indoor unit 313005446653 Special nut B (small flange) 4 For installing indoor unit 313005446759 Installation template 1 For positioning the indoor unit 9360022004 Auxiliary pipe assembly 1 For connecting the piping 9374714025 Remote control 1 For air conditioner operation 9379219037 Remote control holder 1 For installing remote control on the wall 9305642045 Battery 2 For remote control 0600185541 Tapping screw 2 For mounting the remote control holder 0700019036 OUTDOOR UNIT Name and Shape 2012.04.29 Q'ty Application Part number Drain pipe 1 For drain piping work 9303029015 Drain cap 2 For drain piping work 313166024302 One-touch bush 2 For drain piping work 9378779013 29 OPTIONAL PARTS Name and Shape Model name Use Wired remote control UTY-RNNYM Unit control is performed by wired remote control Simple remote control UTY-RSNYM For air conditioner operation Drain pump unit UTR-DPB24T Round flange UTD-RF204 To take fresh air External connect kit UTY-XWZXZ2 For control input/output port External connect kit UTY-XWZX For control input/output port External connect set UTD-ECS5A Use to connect with various peripheral devices and air conditioner PC board. (Set of 6) INPUT / OUTPUT 2012.07.25 (x1) (x2) (x1) (x2) 30 1204G4041