Split Type Air Conditioners

   EMBED


Share

Transcript

EDMY041423 Warning ENGINEERING DATA Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. EDMY041423 Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Split Type Air Conditioners Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. FTKV-N Series Specifications, designs and other content appearing in this brochure are current as of June 2014 but subject to change without notice. c All rights reserved AK Split Type Air Conditioners - Cooling Only FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Cooling Only 1. 2. 3. 4. FTKV25NVMM FTKV35NVMM FTKV50NVMM FTKV60NVMM RKV25NVM RKV35NVM RKV50NVM RKV60NVM Power Supply ..........................................................................................2 Functions.................................................................................................3 Specifications ..........................................................................................4 Dimensions .............................................................................................6 4.1 Indoor Unit................................................................................................6 4.2 Outdoor Unit .............................................................................................7 5. Wiring Diagrams......................................................................................8 5.1 Indoor Unit................................................................................................8 5.2 Outdoor Unit .............................................................................................9 6. Piping Diagrams....................................................................................10 6.1 Indoor Unit..............................................................................................10 6.2 Outdoor Unit ...........................................................................................11 7. Capacity Tables ....................................................................................12 7.1 Cooling Only...........................................................................................12 7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference) ............................................................................................14 8. Operation Limit......................................................................................15 9. Sound Level ..........................................................................................16 9.1 Measuring Location ................................................................................16 9.2 Indoor Unit..............................................................................................16 9.3 Outdoor Unit ...........................................................................................17 10.Electric Characteristics..........................................................................18 11.Installation Manual ................................................................................19 11.1 25/35 Class ............................................................................................19 11.2 50/60 Class ............................................................................................29 12.Operation Manual..................................................................................39 13.Optional Accessories ............................................................................74 13.1 Option List ..............................................................................................74 13.2 Air Direction Adjustment Grille........................................75 13.3 Air Direction Adjustment Grille........................................76 Split Type Air Conditioners FTKV-N Series 1 Power Supply EDMY041423 1. Power Supply Note: 2 Indoor Unit Outdoor Unit FTKV25NVMM RKV25NVM FTKV35NVMM RKV35NVM FTKV50NVMM RKV50NVM FTKV60NVMM RKV60NVM Power Supply 1 φ, 220 - 230 - 240 V, 50 Hz 1 φ, 220 - 230 V, 60 Hz Power Supply Intake ; Outdoor Unit Split Type Air Conditioners FTKV-N Series EDMY041423 Functions Basic Function Inverter (with inverter power control) Operation limit for cooling (°CDB) Operation limit for heating (°CWB) Compressor Comfortable Airflow Comfort Control Operation z Health & Clean Functions FTKV50/60NVMM RKV50/60NVM z 19.4 19.4 ~ 46 ~ 46 Category FTKV25/35NVMM RKV25/35NVM Functions FTKV50/60NVMM RKV50/60NVM Category FTKV25/35NVMM RKV25/35NVM 2. Functions Air-purifying filter — — Photocatalytic deodorising filter — — Air-purifying filter with photocatalytic deodorising function — — Titanium apatite photocatalytic air-purifying filter z z z — — PAM control z z Standby electricity saving — z Oval scroll compressor — — Air filter (prefilter) z Swing compressor z z Wipe-clean flat panel z z Rotary compressor — — Washable grille — — — Reluctance DC motor z z MOULD PROOF operation — Power-airflow flap — — Heating dry operation — — Power-airflow dual flaps z z Good-sleep cooling operation — — Power-airflow diffuser — — Wide-angle louvres z z Auto-swing (up and down) z z Auto-swing (right and left) — z 3-D airflow — z COMFORT AIRFLOW operation — Auto fan speed WEEKLY TIMER operation — z 24-hour ON/OFF TIMER z z NIGHT SET mode z z Auto-restart (after power failure) z z Self-diagnosis (digital, LED) display z z z Wiring error check function — — z z Indoor unit quiet operation z z Anti-corrosion treatment of outdoor heat exchanger z z NIGHT QUIET mode (automatic) — — — z z Multi-split / split type compatible indoor unit — OUTDOOR UNIT QUIET operation (manual) z z INTELLIGENT EYE operation z z Timer Worry Free (Reliability & Durability) Flexibility Flexible power supply correspondence Chargeless 10 m 10 m Quick warming function — — Either side drain (right or left) z z Hot-start function — — Power selection — — 5-room centralised controller (option) — — Remote control adaptor (normal open pulse contact) (option) — — Remote control adaptor (normal open contact) (option) — — DIII-NET compatible (adaptor) (option) — — Wireless z z Wired — — Automatic defrosting — — Automatic operation — — Programme dry operation z z Fan only z z — — Inverter POWERFUL operation z z Priority-room setting — — COOL / HEAT mode lock — — HOME LEAVE operation — — ECONO operation z z Indoor unit ON/OFF button z z Signal receiving sign z z R/C with back light z z Temperature display — — Lifestyle New POWERFUL operation Convenience (non-inverter) Remote Control Remote Controller Note: z : Available — : Not available Split Type Air Conditioners FTKV-N Series 3 Specifications EDMY041423 3. Specifications 50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V Model Indoor Unit Outdoor Unit Capacity Rated (Min. ~ Max.) Moisture Removal Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) COP (Rated) Liquid Piping Connections Gas Drain Heat Insulation Max. Interunit Piping Length Max. Interunit Height Difference Chargeless Amount of Additional Charge of Refrigerant Indoor Unit Front Panel Colour H M Airflow Rate L SL Type Fan Motor Output Speed Air Direction Control Air Filter Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) Temperature Control Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight (Mass) Gross Weight (Gross Mass) Sound Pressure H / M / L / SL Level Outdoor Unit Casing Colour Type Compressor Model Motor Output Type Refrigerant Oil Charge Type Refrigerant Charge H Airflow Rate SL Type Fan Motor Output Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) Starting Current Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight (Mass) Gross Weight (Gross Mass) Sound Pressure H / SL Level Drawing No. Note: 4 kW Btu/h kcal/h L/h A W % W/W mm mm mm m m m FTKV25NVMM RKV25NVM 2.5 (1.2 ~ 3.4) 8,500 (4,100 ~ 11,600) 2,150 (1,030 ~ 2,920) 1.2 2.7 - 2.6 - 2.5 / 2.7 - 2.6 540 90.9 - 90.3 - 90.0 / 90.9 - 90.3 4.63 φ 6.4 φ 9.5 φ 18.0 Both Liquid and Gas Pipes 20 15 10 g/m FTKV35NVMM RKV35NVM 3.5 (1.3 ~ 4.1) 11,900 (4,400 ~ 14,000) 3,010 (1,120 ~ 3,530) 1.9 4.4 - 4.2 - 4.0 / 4.4 - 4.2 910 94.0 - 94.2 - 94.8 / 94.0 - 94.2 3.85 φ 6.4 φ 9.5 φ 18.0 Both Liquid and Gas Pipes 20 15 10 20 20 mm mm kg kg FTKV25NVMM Pure White 7.8 (275) 6.7 (237) 5.6 (198) 4.1 (145) Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downwards Removable / Washable / Mildew Proof 0.15 - 0.14 - 0.13 / 0.15 - 0.14 31 93.9 - 96.3 - 99.4 / 93.9 - 96.3 Microcomputer Control 283 × 800 × 195 265 × 855 × 340 9 12 FTKV35NVMM Pure White 8.0 (282) 6.8 (240) 5.6 (198) 4.6 (162) Cross Flow Fan 40 5 Steps, Quiet, Auto Right, Left, Horizontal, Downwards Removable / Washable / Mildew Proof 0.16 - 0.15 - 0.14 / 0.16 - 0.15 33 93.8 - 95.7 - 98.2 / 93.8 - 95.7 Microcomputer Control 283 × 800 × 195 265 × 855 × 340 9 12 dB(A) 37 / 31 / 25 / 22 38 / 32 / 26 / 23 W A W % A mm mm kg kg RKV25NVM Ivory White Hermetically Sealed Swing Type 1YC25DXD 800 FW68DA 0.375 R-32 0.9 31.8 (1,123) 28.3 (999) Propeller 33 2.55 - 2.46 - 2.37 / 2.55 - 2.46 509 90.7 - 90.0 - 89.5 / 90.7 - 90.0 2.5 550 × 765 × 285 589 × 882 × 363 34 36 RKV35NVM Ivory White Hermetically Sealed Swing Type 1YC25DXD 800 FW68DA 0.375 R-32 0.9 31.8 (1,123) 28.3 (999) Propeller 33 4.24 - 4.05 - 3.86 / 4.24 - 4.05 877 94.0 - 94.1 - 94.7 / 94.0 - 94.1 2.5 550 × 765 × 285 589 × 882 × 363 34 36 dB(A) 46 / 43 47 / 44 3D088571 3D088572 m³/min (cfm) W Steps A W % W L kg m³/min (cfm) „ The data are based on the conditions shown in the table below. Cooling Piping Length Conversion Formulae Indoor ; 27°CDB / 19°CWB Outdoor ; 35°CDB / 24°CWB 7.5 m kcal/h = kW × 860 Btu/h = kW × 3412 cfm = m³/min × 35.3 Split Type Air Conditioners FTKV-N Series EDMY041423 Specifications 50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V Model Indoor Unit Outdoor Unit Capacity Rated (Min. ~ Max.) Moisture Removal Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) COP (Rated) Liquid Piping Connections Gas Drain Heat Insulation Max. Interunit Piping Length Max. Interunit Height Difference Chargeless Amount of Additional Charge of Refrigerant Indoor Unit Front Panel Colour H M Airflow Rate L SL Type Fan Motor Output Speed Air Direction Control Air Filter Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) Temperature Control Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight (Mass) Gross Weight (Gross Mass) Sound Pressure H / M / L / SL Level Outdoor Unit Casing Colour Type Compressor Model Motor Output Type Refrigerant Oil Charge Type Refrigerant Charge H Airflow Rate SL Type Fan Motor Output Running Current (Rated) Power Consumption (Rated) Power Factor (Rated) Starting Current Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight (Mass) Gross Weight (Gross Mass) Sound Pressure H / SL Level Drawing No. Note: kW Btu/h kcal/h L/h A W % W/W mm mm mm m m m FTKV50NVMM RKV50NVM 5.2 (1.7 ~ 6.0) 17,700 (5,800 ~ 20,500) 4,470 (1,460 ~ 5,160) 2.9 6.0 - 5.7 - 5.5 / 6.0 - 5.7 1,300 98.5 - 99.2 - 98.5 / 98.5 - 99.2 4.00 φ 6.4 φ 12.7 φ 18.0 Both Liquid and Gas Pipes 30 20 10 g/m FTKV60NVMM RKV60NVM 6.0 (1.9 ~ 7.0) 20,500 (6,500 ~ 23,900) 5,160 (1,630 ~ 6,020) 3.9 7.4 - 7.1 - 6.8 / 7.4 - 7.1 1,580 97.1 - 96.8 - 96.8 / 97.1 - 96.8 3.80 φ 6.4 φ 12.7 φ 18.0 Both Liquid and Gas Pipes 30 20 10 20 20 mm mm kg kg FTKV50NVMM Pure White 14.3 (504) 12.4 (437) 10.1 (356) 9.0 (317) Cross Flow Fan 43 5 Steps, Quiet, Auto Right, Left, Horizontal, Downwards Removable / Washable / Mildew Proof 0.19 - 0.18 - 0.18 / 0.19 - 0.18 34 81.3 - 82.1 - 78.7 / 81.3 - 82.1 Microcomputer Control 290 × 1,050 × 250 361 × 1,145 × 364 12 17 FTKV60NVMM Pure White 15.4 (544) 13.5 (478) 11.4 (402) 9.9 (350) Cross Flow Fan 43 5 Steps, Quiet, Auto Right, Left, Horizontal, Downwards Removable / Washable / Mildew Proof 0.21 - 0.20 - 0.19 / 0.21 - 0.20 40 86.6 - 87.0 - 87.7 / 86.6 - 87.0 Microcomputer Control 290 × 1,050 × 250 361 × 1,145 × 364 12 17 dB(A) 43 / 39 / 34 / 31 45 / 40 / 35 / 32 W A W % A mm mm kg kg RKV50NVM Ivory White Hermetically Sealed Swing Type 2YC40BXD 1,300 FW68DA 0.650 R-32 1.2 49.5 (1,748) 45.8 (1,617) Propeller 53 5.81 - 5.52 - 5.32 / 5.81 - 5.52 1,266 99.0 - 99.7 - 99.2 / 99.0 - 99.7 3.5 735 × 825 × 300 784 × 960 × 390 43 48 RKV60NVM Ivory White Hermetically Sealed Swing Type 2YC40BXD 1,300 FW68DA 0.650 R-32 1.2 53.4 (1,886) 45.8 (1,617) Propeller 53 7.19 - 6.90 - 6.61 / 7.19 - 6.90 1,540 97.4 - 97.0 - 97.1 / 97.4 - 97.0 3.5 735 × 825 × 300 784 × 960 × 390 43 48 dB(A) 48 / 44 52 / 46 3D088575 3D088576 m³/min (cfm) W Steps A W % W L kg m³/min (cfm) „ The data are based on the conditions shown in the table below. Cooling Piping Length Conversion Formulae Indoor ; 27°CDB / 19°CWB Outdoor ; 35°CDB / 24°CWB 7.5 m kcal/h = kW × 860 Btu/h = kW × 3412 cfm = m³/min × 35.3 Split Type Air Conditioners FTKV-N Series 5 Dimensions EDMY041423 4. Dimensions 4.1 Indoor Unit AIR FLOW (INDOOR) THE MARK (→) SHOWS PIPING DIRECTION REAR 30 MIN. (SPACE FOR MAINTENANCE) FTKV25/35NVMM 800 LEFT RIGHT ( INCLUDING MOUNTING PLATE ) 50 MIN. 197 50 MIN. (SPACE FOR MAINTENANCE) 195 (SPACE FOR MAINTENANCE) REQUIRED SPACE SIGNAL RECEIVER TIMER LAMP INTELLIGENT EYE LAMP 283 NAME PLATE OPERATION LAMP TERMINAL BLOCK WITH EARTH TERMINAL INTELLIGENT EYE SENSOR BOTTOM GAS PIPE φ9.5 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 390) INDOOR UNIT ON/OFF SWITCH FRONT PANEL FIXED SCREWS (INSIDE) FLAPS ROOM TEMP. THERMISTOR (INSIDE) LIQUID PIPE φ 6.4 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 340) SIGNAL TRANSMITTER DRAIN HOSE (CONNECTING PART I.D. φ14 O.D. φ18 THE HOSE LENGTH OF OUTSIDE THE UNIT IS APPROX. 440) 17 711 13 800 (23.4) 49 BLADE ANGLE 283 44.5 (188.7) FAN 180 UP/DOWN (AUTOMATIC) COOLING, DRY 60 50˚ 44.5 5˚ 10˚ 110 WALL HOLE FOR EMBEDDED PIPING φ65 HOLE 70˚ (58.5) STANDARD LOCATIONS OF WALL HOLES RIGHT/LEFT (MANUAL) WIRELESS REMOTE CONTROLLER (ARC466A15) WALL HOLE φ65 HOLE 3D088952 45˚ 45˚ FTKV50/60NVMM THE MARK (→) SHOWS PIPING DIRECTION LEFT REAR REAR MIN.30 (SPACE FOR MAINTENANCE) AIR FLOW (INDOOR) (FOR PERFORMANCE AND MAINTENANCE) 1050 RIGHT INCLUDING ( INSTALLATION PLATE ) 252 250 290 MIN. 50 MODEL NAME (SPACE FOR PLATE MAINTENANCE) BOTTOM FRONT GRILLE FIXING SCREWS (INSIDE) SIGNAL RECEIVER MIN. 50 (SPACE FOR MAINTENANCE) REQUIRED SPACE TERMINAL BLOCK WITH EARTH TERMINAL (INSIDE) INTELLIGENT EYE SENSOR OPERATION LAMP TIMER LAMP INTELLIGENT EYE LAMP INDOOR UNIT ON/OFF SWITCH ROOM TEMP. THERMISTOR (INSIDE) BLADE ANGLES 1050 893.5 155.5 10˚ 5˚ 40˚ 10˚ 5˚ 35˚ 40˚ 35˚ FAN VERTICAL BLADE(AUTOMATIC) 60 5˚ (58.5) WIRELESS REMOTE CONTROLLER (ARC466A14) 6 52.5 14.5 DRY 52 (188.7) COOLING 5˚ 55˚ 30 HORIZONTAL BLADE (AUTOMATIC) THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 530) 290 (23.4) LIQUID PIPE φ 6.4 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 480) MODEL NAME PLATE FLAPS 50˚ 55˚ 50˚ WALL HOLE FOR EMBEDDED PIPING φ80 HOLE 99.5 52 SIGNAL TRANSMITTER DRAIN HOSE FOR VP13 (CONNECTING PART I.D.14.0, O.D.18.0) GAS PIPE φ12.7 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 430) WALL HOLE φ80 HOLE STANDARD LOCATIONS OF WALL HOLES 3D088953 Split Type Air Conditioners FTKV-N Series EDMY041423 4.2 Dimensions Outdoor Unit DRAIN OUTLET (I.Dφ15.9 HOSE FOR CONNECTION) 574 150 50 50 50 100 50 300 100 13 490 29.5 311 WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 1200 MINIMUM SPACE FOR AIR PASSAGE 4-HOLES FOR ANCHOR BOLTS (M8 OR M10) 105.5 150 RKV25/35NVM HANDLE BRAND NAME LABEL 8 285 12 765 63 OUTDOOR AIR THERMISTOR MANUFACTURE'S LABEL LIQUID STOP VALVE (φ6.4 CuT) 550 WIRING INLET 105 165 SERVICE PORT 196 22 IN CASE OF REMOVING STOP VALVE COVER GAS STOP VALVE (φ9.5 CuT) 3D073893C DRAIN OUTLET (I.D.φ15.9 HOSE FOR CONNECTION) 825 WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 1200 MINIMUM SPACE FOR AIR PASSAGE 100 RKV50/60NVM 78 350 580 2 50 50 350 300 100 330 25 350 10 50 IN CASE OF REMOVING STOP VALVE COVER BRAND NAME PLATE OUTDOOR AIR TEMPERATURE THERMISTOR TERMINAL STRIP WIRING INLET WITH EARTH TERMINAL 89 64 735 4-HOLES FOR ANCHOR BOLTS (M8 OR M10) NAME PLATE 350 36 124 100 325 LIQUID STOP VALVE (φ6.4 CuT) SERVICE PORT 155 160 18 30 GAS STOP VALVE (φ12.7 CuT) 3D083536A Split Type Air Conditioners FTKV-N Series 7 Wiring Diagrams EDMY041423 5. Wiring Diagrams 5.1 Indoor Unit FTKV25/35NVMM FIELD WIRING. PCB3 PCB1 S26 S27 ~ LED1 H1P RECTIFIER F1U ~ H1 1 3.15A X1M V1 H2 LED2 H2P LED3 H3P H3 TRANSMISSION CIRCUIT BLK 1 WHT 2 RED 3 2 3 CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN. GRN/YLW FG S1W 7 S21 S1 RED t˚ HA R1T M ORG 1 WHT M1F S35 R2T WIRELESS REMOTE CONTROLLER S6 t˚ SIGNAL RECEIVER 5 BLU S29 PCB2 1 PNK S32 YLW S28 RED INTELLIGENT EYE SENSOR ORG S36 : FRAME GROUND : FUSE : PILOT LAMP : FAN MOTOR : SWING MOTOR : PRINTED CIRCUIT BOARD : THERMISTOR : CONNECTOR : OPERATION SWITCH : TERMINAL STRIP : PROTECTIVE EARTH FG F1U H1P~H3P M1F M1S PCB1~PCB4 R1T, R2T S1~S38 S1W X1M BLU BRN PCB4 OUTDOOR INDOOR M M1S 3D046453H FTKV50/60NVMM 1 PCB3 S49 1 LED1 H1P PCB1 S46 1 BLK FU1 F1U BLK ∼ BLK BLK LED2 H2P H1 3.15A C102 V1 MR10 BLK H2 2 3 BLK 1 WHT 2 RED 3 FIELD WIRING. BLK C101 BLK 9 GRN/YLW H3 TRANSMISSION CIRCUIT 9 BLK SW1 CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN. FG S21 t˚ HA 7 RTH1 R1T 4 PCB2 WIRELESS REMOTE CONTROLLER BLU S48 1 SIGNAL RECEIVER 3 MS 3 ~ WHT M1F BLU PNK ORG RED BLU 2 16 8 10 12 14 15 13 11 9 7 PNK 1 1 S41 S32 3 YLW S47 1 YLW 4 ORG BLK INTELLIGENT EYE SENSOR RED ORG BLK 3 S1 BRN 1 RED S36 S25 BLK BLK BLK 1 BLK BLK BLK PCB4 OUTDOOR GRN BLK LED3 H3P BZ X1M BZ C101,C102 FG F1U H1P~H3P MR10 M1F M1S,M2S PCB1~PCB4 R1T,R2T S1~S49 SW1 V1 X1M :BUZZER :CAPACITOR :FRAME GROUND :FUSE :PILOT LAMP :MAGNETIC RELAY :FAN MOTOR :SWING MOTOR :PRINTED CIRCUIT BOARD :THERMISTOR :CONNECTOR :OPERATION SWITCH :VARISTOR :TERMINAL STRIP :PROTECTIVE EARTH t˚ INDOOR R2T MSW MSW M1S M2S 3D064800F 8 Split Type Air Conditioners FTKV-N Series EDMY041423 5.2 Wiring Diagrams Outdoor Unit RKV25/35NVM FIELD WIRING FU1 3.15A MR30 SA1 S11 E1 BLK BRN BRN OUTDOOR 4 1 BLK S100 1 2 2 X12A BLK + ~+ C119 ~ 1 V1 PCB2 Q1 + C6 DB3 S10 ~+ FU2 3.15A 9 ~ + W V U IPM2 MRCW S50 3 1 PCB1 NOTE 1.REFER TO THE NAME PLATE FOR THE POWER REQUIREMENTS. C5, C6, C119 : CAPACITOR DB1, DB2, DB3 : DIODE BRIDGE FU1, FU2, FU3 : FUSE IPM1, IPM2 : INTELLIGENT POWER MODULE L : LIVE L1 : COIL L1R : REACTOR M1C : COMPRESSOR MOTOR M1F : FAN MOTOR MRCW, MR30, MRM10, MRM20 : MAGNETIC RELAY N : NEUTRAL Q1L : OVERLOAD PROTECTOR 9 MR30_B WHT Z2C N=2 MR30_A BLK GRN GRN E2 + C5 DB2 ~ ORG WHT BLK BLK BLK BLK BLK BLK BLK BLK 1 HA2 1 S20 6 1 S110 SW1 S90 1 6 t˚ M Y1E PCB3 PCB1, PCB2, PCB3 S10, S11, S20, S40, S50 S70, S80, S90, S100, S110 HL3, HN3, X11A, X12A R1T, R2T, R3T SA1 3 S80 1 : PRINTED CIRCUIT BOARD : CONNECTOR : THERMISTOR : SURGE ABSORBER t˚ S40 2 1 S70 1 4 7 10111213 X11A t˚ Q1L R1T R2T R3T (OUTDOOR) (DISCHARGE) (CONDENSER) SW1 V1, V2, V3 X1M Y1E Z1C, Z2C, Z3C RED GRN/YLW L N HA1 GRY HL3 YLW HL2 V3 HN3 BLU RED HN2 BLU MRM10 V2 YLW S BLU AC2 + YLW RED WHT BLK BRN ORG BLU 3 RED ~ GRY 3 IPM1 HR2 DB1 + BRN BLK N 2 WHT L1R BLK BLK BLK BLK BLK BLK 2 BLK WHT HR1 L1 RED 1 MRM20 FU3 AC120A WHT YLW ORG BLU N=2 Z3C X1M L 1 WHT INDOOR : FORCED OPERATION SWITCH : VARISTOR : TERMINAL STRIP : ELECTRONIC EXPANSION VALVE COIL : FERRITE CORE : PROTECTIVE EARTH : EARTH MS 3~ M1F Z1C N=4 V U W MS 3~ M1C 3D088119 RKV50/60NVM 3D088286 Split Type Air Conditioners FTKV-N Series 9 Piping Diagrams EDMY041423 6. Piping Diagrams 6.1 Indoor Unit FTKV25/35NVMM FTKV50/60NVMM INDOOR UNIT INDOOR UNIT MUFFLER ASSY HEAT EXCHANGER 7.0 CuT (7.9 CuT) 7.9 CuT 6.4 CuT FIELD PIPING (6.4 CuT) THERMISTOR ON HEAT EXCH. 6.4 CuT THERMISTOR ON HEAT EXCH. CROSS FLOW FAN CROSS FLOW FAN FIELD PIPING (6.4 CuT) M FIELD PIPING (12.7 CuT) 9.5 CuT REFRIGERANT FLOW COOLING 4D083433C 10 M FAN MOTOR FAN MOTOR FIELD PIPING (9.5 CuT) HEAT EXCHANGER 6.4 CuT (12.7 CuT) REFRIGERANT FLOW COOLING 4D083425C Split Type Air Conditioners FTKV-N Series EDMY041423 6.2 Piping Diagrams Outdoor Unit RKV25/35NVM OUTDOOR UNIT HEAT EXCHANGER OUTDOOR TEMPERATURE THERMISTOR 7.0 CuT HEAT EXCHANGER THERMISTOR 6.4 CuT 9.5 CuT 7.0 CuT 7.0 CuT MOTOR OPERATED VALVE 6.4 CuT 4.8 CuT MUFFLER WITH FILTER 6.4 CuT 7.9 CuT M PROPELLER FAN FIELD PIPING LIQUID STOP (6.4 CuT) VALVE DISCHARGE PIPE THERMISTOR COMPRESSOR ACCUMULATOR 9.5 CuT 9.5 CuT MUFFLER FIELD PIPING (9.5 CuT) 9.5 CuTGAS STOP VALVE WITH SERVICE PORT REFRIGERANT FLOW COOLING 3D088154 RKV50/60NVM OUTDOOR UNIT 7.0 CuT HEAT EXCHANGER OUTDOOR TEMPERATURE THERMISTOR 7.0 CuT HEAT EXCHANGER THERMISTOR 6.4 CuT MUFFLER WITH FILTER MOTOR OPERATED VALVE MUFFLER WITH FILTER M 6.4 CuT 7.9 CuT FILTER PROPELLER FAN LIQUID STOP VALVE DISCHARGE PIPE THERMISTOR COMPRESSOR ACCUMULATOR 12.7 CuT GAS STOP VALVE FIELD PIPING (6.4 CuT) FIELD PIPING (12.7 CuT) REFRIGERANT FLOW COOLING 3D087640 Split Type Air Conditioners FTKV-N Series 11 Capacity Tables EDMY041423 7. Capacity Tables 7.1 Cooling Only FTKV25NVMM + RKV25NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V) AFR 7.8 BF 0.05 INDOOR EWB EDB OUTDOOR TEMPERATURE (°CDB) 20 25 30 32 35 40 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 2.46 1.96 0.42 2.35 1.90 0.46 2.23 1.85 0.50 2.28 1.87 0.51 2.21 1.84 0.53 2.10 1.79 0.57 16.0 22 2.57 1.92 0.42 2.46 1.87 0.46 2.34 1.83 0.50 2.40 1.85 0.51 2.33 1.82 0.54 2.21 1.77 0.58 18.0 25 2.68 2.04 0.42 2.57 1.99 0.46 2.46 1.94 0.50 2.51 1.97 0.51 2.44 1.94 0.54 2.33 1.89 0.58 19.0 27 2.73 2.16 0.42 2.62 2.12 0.46 2.51 2.08 0.50 2.57 2.10 0.52 2.50 2.07 0.54 2.38 2.03 0.58 22.0 30 2.90 2.09 0.43 2.79 2.06 0.47 2.68 2.02 0.51 2.74 2.04 0.52 2.67 2.01 0.54 2.56 1.97 0.58 24.0 32 3.01 2.05 0.43 2.90 2.01 0.47 2.79 1.97 0.51 2.86 2.00 0.52 2.79 1.97 0.55 2.67 1.94 0.59 Symbols: Notes: AFR : Airflow rate BF : Bypass factor (m³/min.) EWB : Entering wet bulb temp. (°C) EDB : Entering dry bulb temp. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1. shows nominal (rated) capacities and power input. 2. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 3. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 3D088778 FTKV35NVMM + RKV35NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V) AFR 8.0 BF 0.05 INDOOR OUTDOOR TEMPERATURE (°CDB) EWB EDB 20 25 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 2.97 2.23 0.64 2.97 2.23 0.72 2.97 2.23 0.81 2.97 2.23 0.82 2.97 2.23 0.88 2.93 2.21 0.97 16.0 22 3.60 2.43 0.71 3.44 2.35 0.77 3.28 2.27 0.84 3.36 2.31 0.86 3.26 2.26 0.90 3.10 2.19 0.97 18.0 25 3.75 2.53 0.71 3.59 2.46 0.78 3.44 2.39 0.85 3.52 2.42 0.87 3.42 2.38 0.91 3.26 2.31 0.98 19.0 27 3.83 2.65 0.71 3.67 2.58 0.78 3.51 2.52 0.85 3.60 2.55 0.87 3.50 2.51 0.91 3.34 2.44 0.98 22.0 30 4.06 2.55 0.72 3.90 2.49 0.79 3.75 2.43 0.85 3.84 2.47 0.88 3.74 2.43 0.92 3.58 2.37 0.98 24.0 32 4.21 2.48 0.72 4.06 2.43 0.79 3.90 2.37 0.86 4.00 2.41 0.88 3.90 2.37 0.92 3.74 2.31 0.99 Symbols: AFR : Airflow rate BF : Bypass factor 30 32 35 40 Notes: (m³/min.) EWB : Entering wet bulb temp. (°C) EDB : Entering dry bulb temp. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1. shows nominal (rated) capacities and power input. 2. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 3. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 3D088779 12 Split Type Air Conditioners FTKV-N Series EDMY041423 Capacity Tables FTKV50NVMM + RKV50NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V) AFR 14.3 BF 0.07 INDOOR OUTDOOR TEMPERATURE (°CDB) EWB EDB 20 25 30 32 35 40 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 5.11 3.86 1.00 4.88 3.74 1.10 4.65 3.63 1.20 4.75 3.68 1.23 4.60 3.61 1.29 4.36 3.49 1.38 16.0 22 5.34 3.79 1.01 5.11 3.68 1.11 4.88 3.58 1.20 4.99 3.62 1.23 4.84 3.56 1.29 4.60 3.45 1.39 18.0 25 5.57 3.98 1.01 5.34 3.88 1.11 5.11 3.78 1.21 5.23 3.83 1.24 5.08 3.77 1.30 4.84 3.67 1.39 19.0 27 5.69 4.21 1.02 5.45 4.11 1.11 5.22 4.01 1.21 5.35 4.06 1.24 5.20 4.00 1.30 4.96 3.91 1.40 22.0 30 6.03 4.06 1.03 5.80 3.97 1.12 5.57 3.89 1.22 5.70 3.94 1.25 5.56 3.89 1.31 5.32 3.80 1.40 24.0 32 6.26 3.95 1.03 6.03 3.88 1.13 5.80 3.80 1.23 5.94 3.85 1.26 5.80 3.80 1.31 5.56 3.72 1.41 Symbols: Notes: AFR : Airflow rate (m³/min.) BF : Bypass factor EWB : Entering wet bulb temp. (°C) EDB : Entering dry bulb temp. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1. shows nominal (rated) capacities and power input. 2. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 3. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 3D088780 FTKV60NVMM + RKV60NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V) AFR 15.4 BF 0.07 INDOOR OUTDOOR TEMPERATURE (°CDB) EWB EDB 20 25 30 32 35 40 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 5.90 4.35 1.22 5.63 4.22 1.34 5.36 4.08 1.45 5.48 4.14 1.49 5.31 4.06 1.56 5.03 3.92 1.68 16.0 22 6.16 4.27 1.23 5.90 4.15 1.34 5.63 4.02 1.46 5.75 4.08 1.50 5.59 4.00 1.57 5.31 3.87 1.69 18.0 25 6.43 4.47 1.23 6.16 4.36 1.35 5.89 4.24 1.47 6.03 4.30 1.51 5.86 4.22 1.58 5.58 4.11 1.69 19.0 27 6.56 4.71 1.24 6.29 4.60 1.35 6.03 4.49 1.47 6.17 4.55 1.51 6.00 4.48 1.58 5.72 4.36 1.70 22.0 30 6.96 4.54 1.25 6.69 4.44 1.36 6.42 4.34 1.48 6.58 4.40 1.52 6.41 4.34 1.59 6.14 4.24 1.71 24.0 32 7.23 4.42 1.25 6.96 4.33 1.37 6.69 4.24 1.49 6.86 4.30 1.53 6.69 4.24 1.60 6.41 4.15 1.71 Symbols: AFR : Airflow rate BF : Bypass factor EWB : Entering wet bulb temp. Notes: (m³/min.) (°C) EDB : Entering dry bulb temp. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1. shows nominal (rated) capacities and power input. 2. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 3. Capacities are based on the following conditions. Corresponding refrigerant piping length : 7.5 m Level difference : 0 m 3D088781 Split Type Air Conditioners FTKV-N Series 13 Capacity Tables 7.2 EDMY041423 Capacity Correction Factor by the Length of Refrigerant Piping (Reference) The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping — the distance between the indoor unit and the outdoor unit. 7.2.1 25/35 Class Cooling (R-32) (%) Capacity correction factor 100 90 80 Range of the refrigerant additional charge 5 10 Piping length 7.2.2 20 (m) 15 (R20376) 50/60 Class Cooling (R-32) (%) Capacity correction factor 100 90 80 Range of the refrigerant additional charge 5 10 15 Piping length Note: 14 20 25 30 (m) (R20375) The graphs show the factor when additional refrigerant of the proper quantity is charged. Split Type Air Conditioners FTKV-N Series EDMY041423 Operation Limit 8. Operation Limit RKV25/35NVM 50 46 Pull-down period 30 Continuous operation Outdoor temp. (˚CDB) 40 20 19.4 0 10 14 Notes : The graph is based on the following conditions. • Equivalent piping length 7.5m • Level difference 0m • Air flow rate High 20 23 28 30 Indoor temp. (˚CWB) 4D073983D RKV50/60NVM 50 46 Pull-down period 30 Continuous operation Outdoor temp. (˚CDB) 40 20 19.4 0 10 14 Notes : The graph is based on the following conditions. • Equivalent piping length 7.5m 0m • Level difference High • Air flow rate Split Type Air Conditioners FTKV-N Series 20 23 28 30 Indoor temp. (˚CWB) 4D083533A 15 Sound Level EDMY041423 9. Sound Level 9.1 Measuring Location Indoor Unit Outdoor Unit 1m 0.8 m 1m MICROPHONE MICROPHONE Notes: 1. Operation sound is measured in an anechoic chamber. 2. The data are based on the conditions shown in the table below. Cooling Indoor ; 27°CDB / 19°CWB Outdoor ; 35°CDB / 24°CWB 5m Indoor Unit FTKV25NVMM 70 OVER ALL (dB) NC-70 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L) 60 NC-60 A 37 25 (B.G.N IS ALREADY RECTIFIED) 50 OPERATING CONDITIONS NC-50 POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 STANDARD EXTERNAL STATIC PRESSURE 220-240/220-230V 50/60Hz (H) 30 220-240/220-230V 50/60Hz (L) NC-30 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) NC-60 16 A 43 34 B.G.N IS ALREADY RECTIFIED 50 NC-50 OPERATING CONDITIONS POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 220-240/220-230V 220-240/220-230V 50/60Hz (H) 50/60Hz (L) 30 NC-30 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 38 26 OPERATING CONDITIONS NC-50 POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 STANDARD EXTERNAL STATIC PRESSURE 220-240/220-230V 50/60Hz (H) 30 220-240/220-230V 50/60Hz (L) NC-30 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE NC-20 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 70 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L) 63 A (B.G.N IS ALREADY RECTIFIED) 63 OVER ALL (dB) NC-70 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE NC-60 4D088807 8000 FTKV60NVMM 60 20 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L) 50 4D088789 8000 OVER ALL (dB) NC-70 60 NC-20 FTKV50NVMM 70 OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) 70 FTKV35NVMM NC-20 8000 4D083738A OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) 9.2 Piping Length OVER ALL (dB) NC-70 50/60Hz 50/60Hz SCALE 220-240/220-230V 220-240/220-230V (H) (L) 60 NC-60 A 45 35 B.G.N IS ALREADY RECTIFIED 50 NC-50 OPERATING CONDITIONS POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 220-240/220-230V 220-240/220-230V 50/60Hz (H) 50/60Hz (L) 30 NC-30 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 NC-20 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 8000 4D083739A Split Type Air Conditioners FTKV-N Series EDMY041423 Outdoor Unit RKV25NVM RKV35NVM 70 60 A NC-60 50/60Hz 220-240/220-230V (H) 46 (B.G.N. IS ALREADY RECTIFIED) 50 OPERATING CONDITIONS NC-50 POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 220-240/220-230V 50/60Hz (H) 30 NC-30 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 50/60Hz 220-240/220-230V (H) A 47 (B.G.N IS ALREADY RECTIFIED) 50 OPERATING CONDITIONS NC-50 POWER SOURCE 220-240/220-230V 50/60Hz JIS STANDARD 40 NC-40 220-240/220-230V 50/60Hz (H) 30 NC-30 20 70 OVER ALL (dB) NC-70 OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) SCALE APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) NC-20 8000 4D088387A RKV60NVM 70 SCALE 60 NC-60 A 50/60Hz 220-240/220-230V (H) 48 (B.G.N IS ALREADY RECTIFIED) 50 OPERATING CONDITIONS NC-50 POWER SOURCE 220-240/220-230V 50/60Hz (H) 40 JIS STANDARD NC-40 220-240/220-230V 50/60Hz (H) 30 NC-30 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 500 63 125 250 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) NC-60 4D088386A 8000 OVER ALL (dB) NC-70 60 NC-20 RKV50NVM 20 OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) SCALE 20 70 OVER ALL (dB) NC-70 NC-20 8000 Split Type Air Conditioners FTKV-N Series 4D088836A OCTAVE BAND SOUND PRESSURE LEVEL dB (0dB=0.0002µ bar) 9.3 Sound Level OVER ALL (dB) NC-70 SCALE 50/60Hz 220-240/220-230V (H) A 52 60 NC-60 (B.G.N IS ALREADY RECTIFIED) 50 NC-50 OPERATING CONDITIONS POWER SOURCE 220-240/220-230V 50/60Hz (H) 40 JIS STANDARD NC-40 220-240/220-230V 50/60Hz (H) 30 NC-30 20 APPROXIMATE THRESHOLD HEARING NC-20 FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCY (Hz) 4D088837A 17 Electric Characteristics EDMY041423 10. Electric Characteristics Indoor Unit Outdoor Unit Power supply Hz - Volts Voltage range Compressor MCA MFA RHz 50 - 220 50 - 230 FTKV25NVMM RKV25NVM Max. 50 Hz, 264 V Min. 50 Hz, 198 V 50 - 240 60 - 220 60 - 230 8.0 10 42 Max. 60 Hz, 253 V Min. 60 Hz, 198 V 50 - 220 50 - 230 FTKV35NVMM RKV35NVM Max. 50 Hz, 264 V Min. 50 Hz, 198 V 50 - 240 60 - 220 60 - 230 8.8 10 65 Max. 60 Hz, 253 V Min. 60 Hz, 198 V 50 - 220 50 - 230 FTKV50NVMM RKV50NVM Max. 50 Hz, 264 V Min. 50 Hz, 198 V 50 - 240 60 - 220 60 - 230 13.5 15 58 Max. 60 Hz, 253 V Min. 60 Hz, 198 V 50 - 220 50 - 230 FTKV60NVMM RKV60NVM Max. 50 Hz, 264 V Min. 50 Hz, 198 V 50 - 240 60 - 220 60 - 230 RLA OFM W 2.4 0.17 2.3 0.16 2.2 33 Max. 60 Hz, 253 V Min. 60 Hz, 198 V 15 69 0.15 IFM W FLA 0.15 0.14 40 0.13 2.4 0.17 0.15 2.3 0.16 0.14 4.1 0.17 0.16 3.9 0.16 3.7 33 0.15 0.15 40 0.14 4.1 0.17 0.16 3.9 0.16 0.15 5.6 0.19 0.19 5.3 0.18 5.1 53 0.17 0.18 43 0.18 5.6 0.19 0.19 5.3 0.18 0.18 7.0 0.20 0.21 6.7 13.5 FLA 6.4 0.19 53 0.18 0.20 43 0.19 7.0 0.20 0.21 6.7 0.19 0.20 Symbols: Notes: MCA : Min. circuit amps (A) MFA : Max. fuse amps (A) 1. RLA is based on the following conditions. Indoor temp. 27°CDB / 19°CWB Outdoor temp. 35°CDB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. Be sure to install an earth leak detector. (This unit uses an inverter, which means that an earth leak detector capable of handling high harmonics must be used in order to prevent malfunctioning of the earth leak detector.) RHz : Rated operating frequency (Hz) RLA : Rated load amps (A) OFM : Outdoor fan motor IFM : Indoor fan motor W : Fan motor rated output (W) FLA : Full load amps (A) 3D088732 18 Split Type Air Conditioners FTKV-N Series EDMY041423 Installation Manual 11. Installation Manual 11.1 25/35 Class Split Type Air Conditioners FTKV-N Series 19 Installation Manual 20 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 21 Installation Manual 22 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 23 Installation Manual 24 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 25 Installation Manual 26 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 27 Installation Manual EDMY041423 3P363835-4D 28 Split Type Air Conditioners FTKV-N Series EDMY041423 11.2 Installation Manual 50/60 Class Split Type Air Conditioners FTKV-N Series 29 Installation Manual 30 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 31 Installation Manual 32 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 33 Installation Manual 34 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 35 Installation Manual 36 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Installation Manual 37 Installation Manual EDMY041423 3P363835-5A 38 Split Type Air Conditioners FTKV-N Series EDMY041423 Operation Manual 12. Operation Manual Split Type Air Conditioners FTKV-N Series 39 Operation Manual 40 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 41 Operation Manual 42 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 43 Operation Manual 44 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 45 Operation Manual 46 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 47 Operation Manual 48 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 49 Operation Manual 50 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 51 Operation Manual 52 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 53 Operation Manual 54 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 55 Operation Manual 56 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 57 Operation Manual 58 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 59 Operation Manual 60 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 61 Operation Manual 62 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 63 Operation Manual 64 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 65 Operation Manual 66 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 67 Operation Manual 68 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 69 Operation Manual 70 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Split Type Air Conditioners FTKV-N Series Operation Manual 71 Operation Manual 72 EDMY041423 Split Type Air Conditioners FTKV-N Series EDMY041423 Operation Manual 3P363834-3A Split Type Air Conditioners FTKV-N Series 73 Optional Accessories EDMY041423 13. Optional Accessories 13.1 Option List 13.1.1 Indoor Unit Option Name Note: 25/35/50/60 Class 1 Titanium apatite photocatalytic air-purifying filter (without frame) ★ KAF970A46 2 Remote controller loss prevention with chain KKF910A4 ★ Standard accessory 13.1.2 Outdoor Unit Option Name 74 1 Air direction adjustment grille 2 Drain plug 25/35 Class 50/60 Class KPW937A4 KPW945A4 KKP937A4 Split Type Air Conditioners FTKV-N Series EDMY041423 Optional Accessories 13.2 Air Direction Adjustment Grille Q Before Installation Checking the parts Check the following parts Name Louver Installation manual Shape Quantity With 4 screws 1piece 1piece Q Installation Procedure Selection of Installation Location Use when installing in a location that meets the following conditions. zWhen installing near the border to a neighbor's house zIf exhaust blows directly on passers-by because outdoor unit is installed facing a road. zChanging the fan direction of the outdoor unit to prevent it blowing directly on shrubbery, etc. Installation of Louver zInstallation is possible in the four directions: upward, downward, rightward, and leftward. zThe installation screws are attached to the louver. zFirst temporarily attach the louver with 4 screws, then check that the angle is correct, and finally tighten the screws fully. Prepared hole pitch 435mm Fan partition Part A (see figure below) Prepared hole pitch 435mm Fan partition CAUTION 1.Install so that a short circuit is prevented. 2.For the use in snowy regions, avoid installation with the air outlet facing upward. Install so that the air outlet faces leftward, rightward, or downward. Snow accumulates in the air outlet of the outdoor unit, causing malfunction of the main body of the outdoor unit. 3.Be advised that if the fan direction is up, dead leaves and other foreign matter easily accumulates in the exhaust vent. The prepared hole is in between the grating of the grille. Part A (prepared hole) cross section (the shape of either a or b) a) Grille grating Prepared hole b) Grille grating Prepared hole 4P104499-1A Split Type Air Conditioners FTKV-N Series 75 Optional Accessories EDMY041423 13.3 Air Direction Adjustment Grille „ Before installation Check the following parts Name Louver Truss tapping screw Installation manual 1piece M4×4screws(max.7.5kW class) M5×4screws(8.0/9.0kW class) 1piece Shape Quantity „ Installation Procedure Selection of Installation Location Use when installing in a location that meets the following conditions. O When installing near the border to a neighbor's house O If exhaust blows directly on passers-by because outdoor unit is installed facing a road. O If exhaust blows directly on vegetation Space Needed for Installation O A minimum of 100mm is needed between the back of the outdoor unit and any obstructions (walls, etc.) m t ore han 100 Installation of Louvers Caution Attach the louvers overlapping the standard grille. Installing the louvers without the grille would allow hands to enter the fan area, which is dangerous, so be sure to install the standard grille. When pointing up When pointing down (1) Remove the 4 attachment screws from the standard grille. (1) Remove the 4 attachment screws from the standard grille. (2) Install the louver pointed up. (2) Install the louver pointed down. O O Overlap the standard grille and screw both in together. The attachment screws are in the louvers. (3) Installation complete Overlap the standard grille and screw both in together. O The attachment screws are in the louvers. O (3) Installation complete 3P089958-2C 76 Split Type Air Conditioners FTKV-N Series EDMY041423 Warning ENGINEERING DATA Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. EDMY041423 Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Split Type Air Conditioners Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. FTKV-N Series Specifications, designs and other content appearing in this brochure are current as of June 2014 but subject to change without notice. c All rights reserved AK Split Type Air Conditioners - Cooling Only FTKV-N Series