Transcript
Optoway
SPS-73120-CXX0G
1
***********************************************************************************************************************************************************************
SPS-73120-CXX0G/SPS-73120B-CXX0G/SPS-73120A-CXX0G
(RoHS Compliant)
3.3V / CWDM / 1.25 Gbps SFP LC SINGLE-MODE TRANSCEIVER **********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l l l l l
The SPS-73120-CXX0G series single mode transceivers is small form factor pluggable module for bi-directional serial optical data communications such as Gigabit Ethernet and Fibre Channel 1x SM-LC-L FC-PI. It is with the SFP 20-pin connector to allow hot plug capability. This module is designed for single mode fiber and operates at a nominal wavelength of CWDM wavelength. There are eighteen center wavelengths available from 1270 nm to 1610 nm, with each step 20 nm. A guaranteed minimum optical link budget of 32 dB is offered The transmitter section uses a multiple quantum well CWDM DFB laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs Avalanche photodetector preamplifier mounted in an optical header and a limiting post-amplifier IC.
l l l l l l l l l
Hot-Pluggable SFP Footprint LC Optical Transceiver Small Form-Factor Pluggable (SFP) MSA compatible Compliant with IEEE 802.3z Gigabit Ethernet Compliant with Fibre Channel 1X SM-LC-L FC-PI 18 Wavelength (λ): 1270 nm to 1610 nm CWDM DFB LD Transmitter APD High Sensitivity Receiver 32 dB Power Budget at Least AC/AC Coupling according to MSA Single +3.3 V Power Supply RoHS Compliant 0 to 70oC Operation: SPS-73120-CXX0 -5 to 85oC Operation: SPS-73120B-CXX0 -40 to 85oC Operation: SPS-73120A-CXX0 Class 1 Laser International Safety Standard IEC-60825 Compliant
LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC-60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug.
APPLICATIONS l l l l
Gigabit Ethernet Switches and Routers Fibre Channel Switch Infrastructure XDSL Applications Metro Edge Switching
ORDER INFORMATION P/No.
Bit Rate (Gb/s)
SPS-73120-CXX0G SPS-73120B-CXX0G SPS-73120A-CXX0G
1.25 1.25 1.25
1000 BASE
Power Budget (dB) > 32 > 32 > 32
Wavelength Package (nm) CWDM* CWDM* CWDM*
LC SFP LC SFP LC SFP
Temp. (oC)
TX Power RX Sens. RoHS (dBm) (dBm) Compliant
0 to 70 -5 to 85 -40 to 85
5 to 0 5 to 0 5 to 0
-32 -32 -32
Yes Yes Yes
CWDM* Wavelength (0 to 70oC) Central Wavelength -C270 -C290 -C310 -C330 -C350 -C370 -C390 -C410 -C430
Min. (nm) 1264.5 1284.5 1304.5 1324.5 1344.5 1364.5 1384.5 1404.5 1424.5
Typ. (nm) 1270 1290 1310 1330 1350 1370 1390 1410 1430
Max. (nm) 1277.5 1297.5 1317.5 1337.5 1357.5 1377.5 1397.5 1417.5 1437.5
Clasp Color Central Code Wavelength Light Purple -C450 Sky Blue -C470 Yellow Green -C490 Yellow Ocher -C510 Pink -C530 Beige -C550 White -C570 Silver -C590 Black -C610
Min. (nm) 1444.5 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5
Typ. (nm) 1450 1470 1490 1510 1530 1550 1570 1590 1610
Max. (nm) 1457.5 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5
Clasp Color Code Yellow Orange Gray Violet Blue Green Yellow Orange Red Brown
CWDM*: 18 Wavelengths from 1270 nm to 1610 nm, each step 20 nm.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-73120-CXX0G
2
***********************************************************************************************************************************************************************
Absolute Maximum Ratings Parameter Storage Temperature Operating Case Temperature
Power Supply Voltage
Symbol Tstg Topr
Vcc
Min -40 0 -5 -40 -0.5
Max 85 70 85 85 3.6
Units o C o C
Min 3.13 0 -5 -40
Typ 3.3
Max 3.47 70 85 85 300
Notes SPS-73120-CXX0G SPS-73120B-CXX0G SPS-73120A-CXX0G
V
Recommended Operating Conditions Parameter Power Supply Voltage Operating Case Temperature
Power Supply Current Data Rate
Symbol Vcc Topr
ICC (TX+RX)
230 1250
100
Units / Notes V o C / SPS-73120-CXX0G o C / SPS-73120B-CXX0G o C / SPS-73120A-CXX0G mA Mb/s
Transmitter Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V) Parameter Optical Optical Transmit Power Output Center Wavelength Output Spectrum Width Side Mode Suppression Ratio Extinction Ratio Optical Rise Time Optical Fall Time Relative Intensity Noise Electrical Data Input Current – Low Data Input Current – High Differential Input Voltage TX Disable Input Voltage – Low TX Disable Input Voltage – High TX Disable Assert Time TX Disable Deassert Time TX Fault Output Voltage -- Low TX Fault Output Voltage -- High
Symbol
Min
Typ
Max
Units
Po λ ∆λ SMSR ER tr tf RIN
0 λc –5.5
--λc
5 λc +7.5
--30 9
---
1
---
--260 260 -120
dBm nm nm dB dB ps ps dB/Hz
IIL IIH VIH - VIL TDIS, L TDIS, H TASSERT TDEASSERT TFaultL TFaultH
-350 350 2.4 0.5 Vcc 10 1
µA µA V V V µs ms
Peak-to-Peak 3 3
0.5 Vcc+0.3
V V
4 4
0.5 0 2.0
0 2.0
Notes 1 2 -20 dB Width
20 % to 80% Values 20 % to 80% Values
1. Output power is power coupled into a 9/125 µm single mode fiber. 2. ITU-T G.694.2 CWDM wavelength from 1270 nm to 1610 nm, each step 20 nm. 3. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX. 4. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
Receiver Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V) Parameter Optical Sensitivity Maximum Input Power Signal Detect -- Asserted Signal Detect -- Deasserted Signal detect -- Hysteresis
Symbol Sens Pin Pa Pd
Min
Typ
-9 ---45 1.0
-----
Max
Units
-32
dBm dBm dBm dBm dB
-32 ---
Notes 4 4 Transition: low to high Transition: high to low
******************************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-73120-CXX0G
3
***********************************************************************************************************************************************************************
Wavelength of Operation Electrical Differential Output Voltage Output LOS Voltage -- Low Output LOS Voltage -- High
1100 VOH – VOL VOL VOH
0.6 0 2.0
---
1620
nm
2.0 0.5 Vcc+0.3
V V V
5 5
4. Measured at 27-1 PRBS at BER 1E-12. 5. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
******************************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-73120-CXX0G
4
***********************************************************************************************************************************************************************
CONNECTION DIAGRAM
PIN
Signal Name
1 2 3
TX GND TX Fault TX Disable
4
MOD-DFE2
5
MOD-DEF1
6
MOD-DEF0
7 8 9 10
N/C LOS RX GND RX GND
Description
PIN
Signal Name
Description
Transmitter Ground Transmitter Fault Indication Transmitter Disable (Module disables on high or open) Modulation Definition 2 – Two wires serial ID Interface Modulation Definition 1 – Two wires serial ID Interface Modulation Definition 0 – Ground in Module Not Connected Loss of Signal Receiver Ground Receiver Ground
11 12 13
RX GND Receiver Ground RX DATA OUT- Inverse Receiver Data Out RX DATA OUT+ Receiver Data Out
14
RX GND
Receiver Ground
15
Vcc RX
Receiver Power – 3.3V±5%
16
Vcc TX
Transmitter Power – 3.3V±5%
17 18 19 20
TX GND TX DATA IN+ TX DATA INTX GND
Transmitter Ground Transmitter Data In Inverse Transmitter Data In Transmitter Ground
MODULE DEFINITION Module Definition
MOD-DEF2 PIN 4
MOD-DEF1 PIN 5
MOD-DEF0 PIN 6
Interpretation by Host
4
SDA
SCL
LV-TTL Low
Serial module definition protocol
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector (NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2-wire serial CMOS E2PROM protocol of the ATMEL AT24C01A/02/04 family of components.
******************************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-73120-CXX0G
5
***********************************************************************************************************************************************************************
RECOMMENDED CIRCUIT SCHEMATIC VeeT Tx_DISABLE Tx_FAULT
(1,17,20) 3
Tx_DISABLE
2
Tx_FAULT 4.7K to 10KΩ
LD Driver
TD +
18
TD -
19
TD + Z=50Ω
100Ω
TD Z=50Ω
VccT
1μH
16
Vcc 3.3V 10μF
10nF
10μF
10nF
SerDes IC
1μH VccR
15 10μF
10nF
RD -
12
Protocol IC
RD Z=50Ω 100Ω
POST Amp
RD +
13
RD + Z=50Ω
depending on SERDES
4.7K to 10KΩ LOS VeeR MOD_DEF(0)
EEPROM
MOD_DEF(1) MOD_DEF(2)
SFP module
8
LOSS OF SINGAL
(9,10,11,14) 6
MODULE DETECT
5
SCL
4
SDA 4.7K to 10KΩ
4.7K to 10KΩ
Vcc 3.3V 4.7K to 10KΩ
PACKAGE DIAGRAM Units in mm
Note: Specifications subject to change without notice.
******************************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-73120-CXX0G
6
***********************************************************************************************************************************************************************
REVISION HISTORY Version 1.0 2.0 3.0
Subject
Release Date
Initial datasheet Add 1270 to 1450 nm CWDM. 1. Revise package diagram for high port density use 2. Add clasp color codes for 18 wavelengths
2004/1/1 2005/12/1 2008/1/1
******************************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 E-mail:
[email protected]
Fax: 886-3-5979737 http: // www.optoway.com.tw
1/1/2008 V3.0