Ss2000+ Encoder/decoder

   EMBED


Share

Transcript

SS2000+ Encoder/Decoder Installation and Operation Manual 255400 Rev. C1 1216 Printed in U.S.A. © Copyright 2016 Federal Signal Corporation Limited Warranty This product is subject to and covered by a limited warranty, a copy of which can be found at www.fedsig.com/SSG-Warranty. A copy of this limited warranty can also be obtained by written request to Federal Signal Corporation, 2645 Federal Signal Drive, University Park, IL 60484, email to [email protected] or call +1 708-534-3400. This limited warranty is in lieu of all other warranties, express or implied, contractual or statutory, including, but not limited to the warranty of merchantability, warranty of fitness for a particular purpose and any warranty against failure of its essential purpose. 2645 Federal Signal Drive University Park, Illinois 60484-3617 www.fedsig.com Customer Support Technical Support 800-548-7229 • +1 708 534-3400 800-524-3021 • +1 708 534-3400 Contents Safety Messages..................................................................................................................................... 7 General Description................................................................................................................................ 9 Introduction ......................................................................................................................................... 9 Features.............................................................................................................................................. 9 Encoding.................................................................................................................................... 10 Modes of Operation.................................................................................................................... 10 Standalone Two-way Operation................................................................................................. 10 Computer Mode Operation......................................................................................................... 10 Automatic Logging .................................................................................................................... 10 Testing and Alignment.................................................................................................................11 Audio Inputs................................................................................................................................11 Serial Ports..................................................................................................................................11 Relay Outputs.............................................................................................................................11 Activation Buttons.......................................................................................................................11 Remote Activation Inputs............................................................................................................11 Transceiver Interface ................................................................................................................. 12 SS2000+ Encoder............................................................................................................................. 12 Specifications........................................................................................................................................ 13 Connectors, Indicators, Controls and Jumpers................................................................................. 15 Controller Board Connectors............................................................................................................. 15 Remote Activation Inputs Board Connectors..................................................................................... 18 Indicators........................................................................................................................................... 20 Controls............................................................................................................................................. 21 Jumpers............................................................................................................................................. 22 Installation.............................................................................................................................................. 23 Programming the SS2000+............................................................................................................... 23 Describing SSLoader+ Software....................................................................................................... 24 Reading INI file from SS2000+................................................................................................... 25 Installation and Operation Manual 3 Using the SSLoader+ Software............................................................................................................ 25 Using the General Configuration Tab................................................................................................ 25 Digital Communications............................................................................................................. 25 DTMF Communications............................................................................................................. 26 Descriptions of Functions Reported by RTUs–Sent to Printer................................................... 27 Comm Port Parameters............................................................................................................. 27 General Parameters................................................................................................................... 28 Relay Functions......................................................................................................................... 29 RTU Faults................................................................................................................................. 30 Network Settings........................................................................................................................ 31 Using the Activation Function Tab..................................................................................................... 32 Activation Function..................................................................................................................... 32 SS2000+ Activation Button Numbering...................................................................................... 37 Uploading INI File to the SS2000+............................................................................................. 38 Connecting the Transceiver Interface................................................................................................ 38 Unbalanced Interface (TB2)....................................................................................................... 38 Balanced Interface..................................................................................................................... 39 Setting the Jumpers........................................................................................................................... 40 Internal Jumpers........................................................................................................................ 40 External Jumpers....................................................................................................................... 40 Setting the Levels.............................................................................................................................. 41 Setting the Transmit Levels........................................................................................................ 41 Setting the Receive Level.......................................................................................................... 42 Connecting the Relay Outputs (TB1)................................................................................................. 42 Connecting the Remote Activation Inputs (J1, J2, J3, J4)................................................................. 42 Configuring the SS2000+ for operation over Ethernet...................................................................... 43 Setting Up a Virtual Com Port on a PC............................................................................................. 43 Using the SS2000+................................................................................................................................ 46 Unlocking the System........................................................................................................................ 46 Automatic Logging............................................................................................................................. 46 Communication Mode........................................................................................................................ 47 Standalone Mode....................................................................................................................... 47 4 SS2000+ Encoder/Decoder Computer Mode......................................................................................................................... 49 Encoding............................................................................................................................................ 49 Manual Activation.............................................................................................................................. 51 Activating All Sites...................................................................................................................... 51 Activating a Zone....................................................................................................................... 51 Activating an Individual Site....................................................................................................... 52 Menu Selection.................................................................................................................................. 53 Sending the Calibration Tone..................................................................................................... 53 Setting the Date and Time.......................................................................................................... 54 Executing the Self Test............................................................................................................... 54 Getting Service...................................................................................................................................... 55 Figures Figure 1 Desktop SS2000+ Front View................................................................................................ 12 Figure 2 Back of the SS2000+.............................................................................................................. 12 Figure 3 Drawing of back of SS2000+................................................................................................. 15 Figure 4 Back of SS2000+..................................................................................................................... 16 Figure 5 Back of SS2000+..................................................................................................................... 18 Figure 6 LEDs........................................................................................................................................ 21 Figure 7 Controls on the SS2000+....................................................................................................... 22 Figure 9 Unbalanced Interface Connections (TB2)............................................................................ 39 Figure 10 Balanced Interface Connections (TB2).............................................................................. 40 Installation and Operation Manual 5 Tables Table 1 Electrical................................................................................................................................... 13 Table 2 Signaling Formats.................................................................................................................... 13 Table 3 Transceiver Interface Port ...................................................................................................... 13 Table 4 Local Mic Input......................................................................................................................... 14 Table 5 External Mic Input.................................................................................................................... 14 Table 6 Line Input.................................................................................................................................. 14 Table 7 Ethernet Network Connection................................................................................................. 14 Table 8 Environmental.......................................................................................................................... 14 Table 9 Dimensions............................................................................................................................... 14 Table 10 SSLoader+ Icons.................................................................................................................... 24 6 SS2000+ Encoder/Decoder Safety Messages Safety Messages It is important to follow all instructions shipped with this product. This device is to be installed by trained personnel who are thoroughly familiar with the country electric codes and will follow these guidelines as well as local codes. Listed below are important safety instructions and precautions you should follow: Important Notice Federal Signal reserves the right to make changes to devices and specifications detailed in the manual at any time in order to improve reliability, function or design. The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for any inaccuracies. Publications Federal Signal recommends the following publications from the Federal Emergency Management Agency for assistance with planning an outdoor warning system: • The “Outdoor Warning Guide” (CPG 1-17) • “Civil Preparedness, Principles of Warning” (CPG 1-14) • FEMA-REP-1, Appendix 3 (Nuclear Plant Guideline) • FEMA-REP-10 (Nuclear Plant Guideline). Planning • If suitable warning equipment is not selected, the installation site for the siren is not selected properly or the siren is not installed properly, it may not produce the intended optimum audible warning. Follow Federal Emergency Management Agency (FEMA) recommendations. • If sirens are not activated in a timely manner when an emergency condition exists, they cannot provide the intended audible warning. It is imperative that knowledgeable people, who are provided with the necessary information, are available at all times to authorize the activation of the sirens. • When sirens are used out of doors, people indoors may not be able to hear the warning signals. Separate warning devices or procedures may be needed to effectively warn people indoors. • The sound output of sirens is capable of causing permanent hearing damage. To prevent excessive exposure, carefully plan siren placement, post warnings, and restrict access to areas near sirens. • Activating the sirens may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of siren sounds. Siren users should follow FEMA recommendations and instruct those to be warned of correct actions to be taken. Installation and Operation Manual 7 Safety Messages • After installation, service, or maintenance, test the siren system to confirm that it is operating properly. Test the system regularly to confirm that it will be operational in an emergency. • If future service and operating personnel do not have these instructions to refer to, the siren system may not provide the intended audible warning and service personnel may be exposed to death, permanent hearing loss, or other bodily injury. File these instructions in a safe place and refer to them periodically. Give a copy of these instructions to new recruits and trainees. Also give a copy to anyone who is going to service or repair the siren. Installation and Service • Electrocution or severe personal injury can occur when performing various installation and service functions such as making electrical connections, drilling holes, or lifting equipment. Therefore only experienced electricians should install this product in accordance with national, state and any other electrical codes having jurisdiction. Perform all work under the direction of the installation or service crew safety foreman. • The sound output of sirens is capable of causing permanent hearing damage. To prevent excessive exposure, carefully plan siren placement, post warnings and restrict access to areas near the sirens. Sirens may be operated from remote control points. Whenever possible, disconnect all siren power including batteries before working near the siren. • After installation or service, test the siren system to confirm that it is operating properly. Test the system regularly to confirm that it will be operational in an emergency. • If future service personnel do not have these warnings and all other instructions shipped with the equipment to refer to, the siren system may not provide the intended audible warning and service personnel may be exposed to death, permanent hearing loss, or other bodily injury. File these instructions in a safe place and refer to them periodically. Give a copy of these instructions to new recruits and trainees. Also, give a copy to anyone who is going to service or repair the sirens. Operation Failure to understand the capabilities and limitations of your siren system could result in permanent hearing loss, other serious injuries or death to persons too close to the sirens when you activate them or to those you need to warn. Carefully read and thoroughly understand all safety notices in this manual and all operations-related-items in all instruction manuals shipped with equipment. Thoroughly discuss all contingency plans with those responsible for warning people in your community, company, or jurisdiction. 8 SS2000+ Encoder/Decoder General Description General Description Introduction This manual describes the features, specifications, installation, and how to use the SS2000+ encoder. The SS2000+ encoder monitors and controls your siren system. The SS2000+ supports one-way communication with the option of two-way communications using DTMF or FSK encoding. Command sequences are programmable and stored in non-volatile memory chips for retention, even when electrical power is disrupted. For the most advanced systems, connect the SS2000+ to a PC running Federal Signal’s Commander software. Commander and the SS2000+ can work together to monitor and control your system, with the SS2000+ providing full redundancy in the event that your PC is off line. Configure the SS2000+ using the SSLOADER+ software program. Features • Streams Wave files from PC • Compatible with SE3000 Encoder Software and Commander Software • Printer port for standalone operation • Can send printer messages to serial printer • Two serial ports: one for control and one for extra peripheral devices or control • Multiple codes/functions stackable under each button including Relay Outputs • Two-Tone, MSK Packet Digital, EAS and DTMF encode • FLASH/Programming Port • Twenty-four activation buttons on front panel • I2C port for external relays or keyboard for additional activation buttons • Twenty optically isolated remote activation inputs built in (activated by dry contact closure) • Status LEDs and LCD display • Level Meter for Setting Receive Level • Two Line Inputs for Transmission of External Audio Sources (3.5 mm) • XLR Input for microphone, phantom power supply for amplified microphones • External Mic Input VOX (which simulates push-to-talk through audio level) • Three programmable Relay Outputs • High or Low Impedance for radio interface • Carrier Detect from Radio/Transceiver or VOX • Selectable Carrier Detect Polarity Installation and Operation Manual 9 General Description Encoding • Monitor Speaker to Monitor Incoming and Outgoing Traffic • Powered from 12 to 30 Vdc, runs on standard 12 or 24 V backup power Program up to three codes under each activation input. There are sixty programmable functions available. These codes can be Two-Tone, Single-Tone, EAS, DTMF, Federal Signal Digital Codes (FSK) and activating the three Relay Outputs, or calling another activation key. Send each activation code from one to three times. Modes of Operation You can set the SS2000+ in either standalone or computer mode. In either mode, any poll requests or activation commands from Commander Software, updates the clock in the SS2000+ to match the Commander Software time and date. In computer mode, all reports, status, and activations are logged within the Commander Software. The SS2000+ can also receive streamed audio and encode activations from Commander Software or the SE3000 Software and transmit it out as audio. Standalone Two-way Operation Use the SS2000+ in standalone mode; that is, without a host computer application. When in standalone mode, the SS2000+ does not function as a two-way radio modem for the SE3000 Software or Commander Software applications. In standalone mode, the SS2000+ acknowledges and prints incoming status reports and alarms from remote devices. Acknowledgments confirm message receipt and keeps remote devices from repeating transmissions. The SS2000+ is configured with two lists of unit numbers: one for digital units and one for DTMF units. Both types can exist in the same system. When a Report – All is executed, the SS2000+ polls the active units in the digital list first, logging each poll and response. When complete, the SS2000+ polls the units in the DTMF list, logging each poll and response. The DTMF status or alarm messages are converted to the same format as the digital information. The incoming DTMF and digital messages are decoded and displayed on the LCD. Computer Mode Operation The SS2000+ keypad and display are still operational in computer mode, but the SS2000+ does not acknowledge incoming digital messages. It passes all messages to the host computer application. Automatic Logging The SS2000+ displays all incoming and outgoing messages on its LCD display. The SS2000+ prints all status reports on a line printer if the printer is enabled in the configuration. If Com port 2 is configured for printer messages, the statuses and alarms are sent there as well. The SS2000+ also logs each time it is powered up, all manual encode activations, outgoing poll requests, and the results of each step in the self test procedure. 10 SS2000+ Encoder/Decoder General Description Testing and Alignment The SS2000+ has a calibrate function and an LED bar graph to aid in setting receive and transmit levels. It also incorporates a comprehensive built in test routine to test every circuit of the unit. The internal monitor speaker allows the user to hear all incoming and outgoing transmissions to aid in system setup and troubleshooting. Audio Inputs The SS2000+ has two line level inputs, each with its own PTT line, a local mic input with PTT, and an XLR balanced input incorporating a VOX PTT for balanced or distant mics. The XLR input can provide a ghost supply for amplified mics. Use amplified or nonamplified microphone. Serial Ports The SS2000+ has two serial ports. Use COM1 for interfacing with Commander Software or Encoder Software. Use COM2 to send printer messages or receive text messages to a display or peripheral device. Also, use COM2 to interface with Commander Software, Encoder Software, or an external radio modem. Relay Outputs The SS2000+ has three Relay Outputs that you can program to activate when an activation button is pressed. Each relay has an off time and an on time. Alternatively, configure each relay to activate when the unit has not been polled in 30 minutes, when an RTU reports a fault, or when PTT or Carrier Detect are active. Activation Buttons Located on the front panel of the SS2000+ are twenty-four programmable activation buttons that activates functions one through twenty-four. Configure each activation function for Auto Prompt Send or Auto Send. Auto Prompt Send prompts you to press the SEND button after an activation button has been pressed before initiating the activation. Auto Send sends the code out when you press the activation button without being prompted to press SEND. The same method is used with Auto Prompt Send Auto Report and Auto Send Auto Report modes, which include and automated system wide poll after activation. You can print each activation and status reports to a printer. Remote Activation Inputs Located on the back of the SS2000+ are twenty external activation inputs that can be driven by a contact closure. These inputs are optically isolated and activate buttons one through twenty. Debounce time for remote inputs is 250 ms. An input held closed for extended time will not generate multiple activations. These twenty external (rear mount) inputs are factory set to activate activation inputs one through twenty. Modify the jumpers on the internal PCB to allow the inputs to be used for additional functions. For example, use the remote inputs as inputs twenty-one through forty or forty-one through sixty. See “Remote Activation Inputs Board Connectors” on page 18. Installation and Operation Manual 11 General Description Transceiver Interface The transceiver interface features a balanced 600 ohms input and output (optional 10 K ohms) and can accept a wide range of transceiver types and levels. The transmit audio from other encoding equipment can be interrupted during the transmissions of the SS2000+ by the PTT relay. The unit also monitors if other equipment is currently transmitting before attempting to transmit. Carrier detect can work with either polarity or from a VOX. SS2000+ Encoder Figure 1 Desktop SS2000+ Front View LCD Display Keypad Lock Activation Hotkeys Figure 2 Back of the SS2000+ 12 SS2000+ Encoder/Decoder Specifications Specifications Table 1 Electrical D.C. Power Input Current Draw Input Voltage 12-30 Vdc <300 mA Standby, <700 mA max Table 2 Signaling Formats MSK Digital encode/decode 1200 Baud Decode Sensitivity and then click Next. The following dialog box appears. 7. Enter SS2000+ in the Model Name text box. 8. In the Serial Ports box, select 1. 9. Enter the Static IP Address of the SS2000+. 10. Select the This Device Supports Encrypted RealPort check box, and then click Next. 44 SS2000+ Encoder/Decoder Using the SSLoader+ Software The following dialog box appears. 11. Select the com port to use, and then click Next. The program installs the drivers and configures the com port. The following dialog box appears. 12. Click Finish and the SS2000+ is available on the virtual com port . Installation and Operation Manual 45 Using the SS2000+ Using the SS2000+ Unlocking the System The SS2000+ keypad is secured with a key lock switch. When the key is in the LOCK position, the LCD displays Keypad Locked message, time, and date. ** Keypad Locked ** SS2000+ 07:29 06/19/2015 (c) When the key is turned to the UNLOCK position, the keypad is enabled and the standby screen displays on the LCD. The unit is ready to accept commands. Press Function Key F1..F2 to Activate 07:29 06/19/2015 (c) When the unit is powered up, When the SS2000+ is on, the printer prints SS2000+ On Line. Automatic Logging The SS2000+ displays all incoming and outgoing message on the LCD display. If enabled in the configuration, the SS2000+ logs any incoming statuses and alarms DTMF or Digital to the printer. If Com port 2 is configured for Printer Messages, the status and alarms are sent there as well. Also, the SS2000+ logs each time it powered up, all manual encode activations, outgoing poll requests, and the results of each step in the self test procedure. The SS2000+ decodes and displays on the LCD any incoming DTMF of Digital status or alarm messages. A typical message includes the site number, siren type, and alarm or status depending on the message type. Press Function Key F1..F2 to Activate Site# 001 FCD Alarm 07:29 06/19/2015 (s) 46 SS2000+ Encoder/Decoder Using the SS2000+ Whenever the SS2000+ attempts to transmit, the following occurs: a. If the radio channel is busy and Carrier Detect is active, the LCD displays the following. F01: Function Name Waiting for Carrier The SS2000+ waits ten seconds for the channel to clear before transmitting. b. If other equipment is currently transmitting, the LCD displays the following. F01: Function Name Waiting for PTT The SS2000+ waits for other transmission to end before transmitting. Communication Mode You can use the SS2000+ in either standalone or computer mode. The mode the SS2000+ is in is indicated by the character at the end of the fourth line on of the LCD panel. The (s) stands for standalone mode and (c) stands for computer mode. To switch between modes, from the STANDBY screen, press MODE. The SS2000+ LCD displays the following: About to change Mode to: standalone Press SEND to Change Or CLEAR to Cancel Standalone Mode In standalone mode, the SS2000+ acknowledges any incoming Digital Alarms and logs them. Any incoming DTMF alarms are converted to Federal Signal digital and are logged as well. Requesting Reports and Polling The SS2000+ is configured with two lists of unit numbers: • One for digital units • One for DTMF units Installation and Operation Manual 47 Using the SS2000+ When a Report - All is executed, the SS2000+ polls the units in the Digital list and logs each poll and response. When complete, the SS2000+ polls the units in the DTMF list, converting the DTMF reply to the same format as the Digital information and logs each poll and response. To request a report from all of the sites, do the following: 1. Press the REPORT key from the STANDBY screen. The SS2000+ LCD displays the following. Select: ALL or SITE REPORT STANDBY 2. Press ALL and the SS2000+ polls the sites in its site lists. 3. Press CLEAR to stop the process and return to the STANDBY screen. To request a report from an individual site, do the following: 1. Press the REPORT key from the STANDBY screen. 2. Press MODE/SITE. The SS2000+ LCD displays the following: Enter Site: Sites = 1 to 256 REPORT SEND to START 3. Enter the site number. 4. Press CLEAR to clear the site number for re-entry. 5. Pressing CLEAR again or MENU, stops the process and returns you to the STANDBY screen. 6. Press SEND and the SS2000+ polls the site and logs the results. The SS2000+ LCD displays the following: Site#001 Requesting Report REPORT STANDBY 48 SS2000+ Encoder/Decoder Using the SS2000+ Computer Mode Requesting Reports and Polling Any poll requests or activation commands from Commander software are examined by the SS2000+ for time and date. The SS2000+ updates its internal clock to match, and then sends the Digital message. When Commander sends a poll request, the SS2000+ LCD displays the following. Requesting Report: Site# 001 REPORT STANDBY The resulting reports are logged and sent to the Commander software. Incoming DTMF messages are converted to Digital format, logged, and sent to Commander as well. These transmissions are not acknowledged by the SS2000+. Streaming Mode In computer mode, the SS2000+ can also receive streamed audio/encode data from Commander software or the SE3000 software and transmit it out as audio. When the SS2000+ is transmitting streamed audio encode data, the SS2000+ LCD displays the following: Streaming Audio Encoding You can program up to 3 codes under each of 60 activation functions. These can be as following: Two-Tone/Single-Tone codes • 282 Hz to 3000 Hz, Timing, 0.5 sec min to 8 sec max DTMF codes up to 16 characters • 35 ms/5 ms to 100 ms/100 ms timing Federal Signal one-way Digital Codes • 1 to 255 Individual site, 300=All Call, 1 to 16 for zones 1 to 16 • 1 to 512 Individual site, 800=All Call if extended site numbers are used • Function Number 1 to 50, 97=Cancel, 98=Quiet Test, 99=Reset Installation and Operation Manual 49 Using the SS2000+ Cycling the 3 Relay Outputs • Off times and on times 0 to 999 seconds Calling another activation key The 24 activation buttons activate functions 1 to 24. You can use the rear mounted activation to activate functions 1 to 20 or you can modify jumpers to use the rear mounted inputs as additional activation inputs. You can configure each activation function for the following: • Auto Prompt Send • Auto Send Auto Prompt Send Auto Prompt Send prompts you to press the SEND button after an activation button has been pressed. The SS2000+ LCD displays the name of the function activated. F01: SEND to Transmit Once done, the unit sends out the codes for that function. Auto Send Auto Send sends the codes out when you press an activation button or closes a remote activation input without prompting you to press SEND. The SS2000+ LCD displays the name of the function activated. Sending: Function Name Auto Prompt Send Auto Report prompts you to press the SEND button after an activation button has been pressed. After the activation, the SS2000+ polls the sites it is configured for. Auto Send Auto Report sends the codes out when you press an activation button or closes a remote activation input without prompting you to press SEND. After the activation, the SS2000+ polls the sites it is configured for. You can program activation buttons as Manual. When you press a button, the SS2000+ prompts you for where the message is to be sent: All, Zone, or Site. You can only use Manual with Digital functions. Press CLEAR to stop the process and return to the STANDBY screen. 50 SS2000+ Encoder/Decoder Using the SS2000+ Manual Activation From the STANDBY screen, press the MANUAL ACT button The SS2000+ LCD displays the following. Manual Activation Select: ALL ZONE or SITE MANUAL ACTIV STANDBY Activating All Sites To activate all sites, do the following: 1. Press the MANUAL ACT button. 2. Press the ALL button. The SS2000+ prompts for the desired function number. Enter Function: 1-50, 97=Cancel 98=QuietTest 99=Rset MANUAL SEND to START 3. Press the SEND button. Press the CLEAR button to stop the process and return to the STANDBY screen. Activating a Zone To activate a zone, do the following: 1. Press the MANUAL ACT button. 2. Press the ZONE button. NOTE: Your site may have customized buttons. The SS2000+ prompts for the desired zone number. Enter Zone: Zones = 1 to 16 Press SEND to ENTER 3. Enter the zone number. Enter the zone number where zone number is a variable that changes with your site’s zone numbers. Installation and Operation Manual 51 Using the SS2000+ 4. Press the SEND button. The SS2000+ prompts for the Function. Enter Function: 1-50, 97=Cancel 98=QuietTest 99=Rset MANUAL SEND to START 5. Enter the function number. Press the CLEAR button to stop the process and return to the STANDBY screen. Activating an Individual Site To activate an individual site, do the following: 1. Press the MANUAL ACT button. 2. Press the MODE/SITE button. The SS2000+ prompts for the desired site number. Enter Site: Sites = 1 to 255 Press SEND to ENTER 3. Enter the site number. 4. Press the SEND button. The SS2000+ prompts for the Function. Enter Function: 1-50, 97=Cancel 98=QuietTest 99=Rset MANUAL SEND to START 5. Enter the function number. Press the CLEAR button to stop the process and return to the STANDBY screen. 6. Press the SEND button. 52 SS2000+ Encoder/Decoder Using the SS2000+ Menu Selection The following section explains how the use the SS2000+ menu section. To view the menu selection, press the MENU button. The SS2000+ LCD displays the following. 1. 2. 3. 4. Printer Status Send Calibrate Set Date and Time Test Mode The following table describes the menu features. Menu Number Description 2. Send Calibrate Sends the calibration tone. 1. Printer Status Displays the current printer status: Printer Off, No Paper, Printer Offline, Printer Error, or Printer OK. 3. Set Date and Time 4. Test Mode Sets the date and time. Begins the self test. Sending the Calibration Tone To send the calibration tone, do the following: 1. Press the MENU button. 2. Press 2. The SS2000+ LCD displays the following: SEND to Transmit CAL STANDBY 3. Press SEND. The SS2000+ transmits a 10 second, 1 kHz sinewave. This sets transmitter deviation. The SS2000+ LCD displays the following. SEND to Transmit Sending Installation and Operation Manual 53 Using the SS2000+ After 10 seconds, the SS2000+ LCD displays the following. SEND to Transmit CLEAR to Quit 4. Press SEND to send the tone for another 10 seconds or press CLEAR or MENU to return to the STANDBY screen. Setting the Date and Time To set the date and time, do the following: 1. Press the MENU button. 2. Press 3. The SS2000+ LCD displays the following: '+' or '-' to Change SEND to move to Next | 16:24:38 6/01/2015 Press Action + Increases the number in the field SEND Moves the Pointer | to the next field. - Decreases the number in the field. 3. Press CLEAR or MENU to save the date and time on the display and return to the STANDBY screen. Executing the Self Test To execute the self test, do the following: 1. Press the MENU button. 2. Press 4. The SS2000+ LCD displays the following. LCD Message Test; Press (+) if OK. Press (-) if Failed CLEAR Key to quit. 54 SS2000+ Encoder/Decoder Getting Service Getting Service If you are experiencing any difficulties, contact Federal Signal Customer Care at: 800-548-7229 or 708-534-3400 extension 5822 or Technical Support at: 800-524-3021 or 708-534-3400 extension 7329 or through e mail at: [email protected]. For instruction manuals and information on related products, visit: http://www.fedsig.com/ Installation and Operation Manual 55 2645 Federal Signal Drive University Park, Illinois 60484-3617 www.fedsig.com Customer Support Technical Support 800-548-7229 • +1 708 534-3400 800-524-3021 • +1 708 534-3400