Transcript
SSZ16
High-Efficiency Split System Heat Pump Up to 16 SEER Cooling Capacity: 24,000 to 57,000 BTU/h Heating Capacity: 24,000 to 57,000 BTU/h
Contents
Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 4 Expanded Heating Data........................ 12 AHRI Ratings......................................... 13 Dimensions........................................... 17 Wiring Diagram..................................... 18 Accessories........................................... 19
Standard Features
• • • • • • • • • • • • • • •
High-efficiency scroll compressor High-density foam compressor sound blanket SmartShift® technology to ensure quiet, reliable defrost Factory-installed bi-flow liquid-line filter drier Factory-installed suction-line accumulator Compressor short-cycle protection 850 RPM condenser fan motor Factory-installed compressor crankcase heater Factory-installed high-capacity muffler High- and low-pressure switches Service valves with sweat connections with easy access to gauge ports Copper tube / enhanced aluminum fin coil Contactor with lug connection Ground lug connection AHRI Certified; ETL Listed
Cabinet Features
• • • •
Goodman® brand sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Top and side compressor and tubing access • Service ports and controls are accessible while unit is operating • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home) and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.
SS-SSZ16
www.goodmanmfg.com
6/15 Supersedes 9/14
Nomenclature
S
S
Z
16
036
1
A
A
1
2
3
4,5
6,7,8
9
10
11
Brand S Goodman® (High Feature Set Model)
Engineering * Minor Revision Engineering * Major Revision
Product Category S Split System Unit Type X Condenser R-‐410A Z Heat Pump R-‐410A
1 2 3 4
Efficiency 13 13 SEER 14 14 SEER 16 16 SEER
018 024 030 036/38
Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz 208/230 V, 3 Phase, 60 Hz 460 V, 3 Phase, 60 Hz
1½ Tons 2 Tons 2½ Tons 3 Tons
Nominal Capacity 042 3½ Tons 048 4 Tons 060 5 Tons
* Neither used for order entry or inventory management.
2
www.goodmanmfg.com
SS-SSZ16
Product Specifications
SSZ16 0241A
SSZ16 0361A
SSZ16 0481A
SSZ16 0601B
24,000 24,000 70
36,000 36,000 71
48,000 48,000 72
60,000 60,000 72
Compressor RLA LRA
13.5 58.3
14.1 77.0
19.9 109.0
28.8 152.9
Condenser Fan Motor Horsepower FLA
1/6 1.1
1/6 1.0
1/6 1.0
1/6 1.0
⅜" ¾"
⅜" ⅞"
⅜" 1⅛"
⅜" 1⅛"
⅜" ¾" Sweat 153
⅜" ⅞" Sweat 186
⅜" ⅞" Sweat 278
⅜" ⅞" Sweat 273
208/230-60 17.9
208/230-60 18.6
208/230-60 25.9
208/230-60 37
30 197/253 ½" or ¾"
30 197/253 ½" or ¾"
40 197/253 ½" or ¾"
60 197/253 ½" or ¾"
Equipment Weight (lbs)
190
233
305
309
Ship Weight (lbs)
208
255
327
331
Capacities and Ratings Nominal Cooling (BTU/h) Nominal Heating (BTU/h) Decibels
Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge Electrical Data Volts-Hz Minimum Circuit Ampacity ² Max. Overcurrent Protection ³ Min / Max Volts Electrical Conduit Size
¹ Tested and rated in accordance with AHRI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the rating plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
SS-SSZ16
www.goodmanmfg.com
3
4
www.goodmanmfg.com
23.9 0.89 20 1.45 5.6 215 113 23.2 0.85 21 1.44 5.6 213 112 21.4 0.82 21 1.40 5.4 207 108
MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR
766
875
984
59 23.5 0.78 17 1.44 5.6 213 112 22.8 0.75 18 1.43 5.5 211 110 21.1 0.72 18 1.39 5.4 205 107
Airflow MBh S/T ∆T kW 984 Amps Hi PR Lo PR MBh S/T ∆T kW 875 Amps Hi PR Lo PR MBh S/T ∆T 766 kW Amps Hi PR Lo PR
24.6 0.80 18 1.48 5.8 232 120 23.9 0.76 19 1.47 5.7 230 119 22.1 0.73 19 1.43 5.6 223 115
63 24.4 0.65 15 1.47 5.7 230 119 23.7 0.62 15 1.46 5.7 227 117 21.8 0.60 16 1.42 5.5 220 114 26.7 0.60 15 1.53 5.9 245 131 25.9 0.57 16 1.51 5.9 242 130 23.9 0.55 16 1.48 5.7 235 126
67 26.7 0.45 11 1.51 5.9 242 130 25.9 0.43 12 1.50 5.8 240 128 23.9 0.42 12 1.47 5.7 233 124 28.6 0.39 10 1.58 6.2 255 139 27.8 0.37 11 1.56 6.1 253 138 25.6 0.36 11 1.53 5.9 245 134
71 23.4 0.92 20 1.56 6.1 242 119 22.7 0.88 21 1.55 6.0 239 118 20.9 0.85 21 1.51 5.9 232 114
59 23.0 0.81 17 1.55 6.0 239 118 22.3 0.77 18 1.54 6.0 237 117 20.6 0.75 18 1.50 5.8 230 113 24.1 0.82 19 1.59 6.2 260 127 23.4 0.79 19 1.58 6.2 258 125 21.6 0.76 20 1.54 6.0 250 122
63 23.8 0.68 15 1.58 6.2 258 125 23.1 0.65 16 1.57 6.1 255 124 21.3 0.62 16 1.53 5.9 247 120 26.0 0.62 15 1.64 6.4 275 138 25.3 0.59 16 1.63 6.3 272 137 23.3 0.57 16 1.59 6.2 264 133
67 26.1 0.47 11 1.63 6.3 272 137 25.3 0.45 12 1.62 6.3 269 136 23.4 0.43 12 1.58 6.1 261 131
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
27.9 0.40 10 1.70 6.6 287 147 27.1 0.38 11 1.68 6.6 284 146 25.0 0.37 11 1.64 6.4 275 141
71 22.8 0.94 20 1.66 6.6 275 124 22.1 0.90 21 1.64 6.5 272 122 20.4 0.87 21 1.60 6.3 264 119
59 22.4 0.83 17 1.64 6.5 272 122 21.8 0.79 18 1.63 6.5 270 121 20.1 0.76 18 1.59 6.3 261 118 23.5 0.85 19 1.69 6.7 296 132 22.8 0.81 19 1.68 6.7 293 130 21.0 0.78 20 1.64 6.5 284 126
25.4 0.64 15 1.75 6.9 312 144 24.7 0.61 16 1.73 6.9 309 142 22.8 0.59 16 1.69 6.7 300 138
22.2 0.98 20 1.74 7.0 313 130 21.6 0.93 21 1.73 6.9 310 129 19.9 0.90 21 1.69 6.8 301 125
22.9 0.87 19 1.78 7.2 337 138 22.2 0.83 19 1.77 7.1 334 137 20.5 0.80 20 1.72 6.9 324 133
24.8 0.66 15 1.84 7.4 356 151 24.1 0.63 16 1.83 7.3 352 149 22.2 0.61 16 1.78 7.1 342 145
26.6 0.42 11 1.90 7.7 371 161 25.8 0.41 11 1.89 7.6 368 159 23.8 0.39 11 1.84 7.4 357 154
71 -
Shaded area reflects ACCA (TVA) conditions
27.3 0.41 10 1.81 7.2 326 153 26.5 0.39 11 1.79 7.1 323 152 24.4 0.38 11 1.75 6.9 313 147
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.2 25.5 21.9 22.7 24.8 0.69 0.48 0.86 0.72 0.50 15 11 18 15 12 1.68 1.73 1.73 1.77 1.82 6.7 6.9 6.9 7.1 7.3 293 309 310 334 352 130 142 129 137 149 22.6 24.7 21.2 22.0 24.1 0.66 0.46 0.82 0.68 0.47 16 12 18 16 12 1.67 1.72 1.72 1.75 1.81 6.6 6.8 6.9 7.0 7.3 290 306 307 330 349 129 141 127 136 148 20.8 22.8 19.6 20.3 22.3 0.64 0.44 0.79 0.66 0.46 16 12 19 16 12 1.63 1.68 1.67 1.71 1.76 6.4 6.6 6.7 6.9 7.1 281 297 298 320 338 125 137 124 131 143 21.1 1.00 20 1.82 7.4 352 136 20.5 0.97 21 1.80 7.4 349 135 18.9 0.93 21 1.76 7.2 338 131
59 20.8 0.89 17 1.80 7.4 349 135 20.2 0.85 18 1.79 7.3 345 133 18.6 0.82 18 1.74 7.1 335 129 21.8 0.91 18 1.86 7.6 379 145 21.1 0.86 19 1.84 7.5 375 143 19.5 0.83 19 1.80 7.3 364 139
63 21.5 0.74 15 1.84 7.5 375 143 20.9 0.71 16 1.83 7.5 372 142 19.3 0.68 16 1.78 7.3 360 138 25.3 0.44 10 1.98 8.1 418 168 24.5 0.42 11 1.97 8.1 413 167 22.7 0.41 11 1.92 7.9 401 162
71 19.6 1.00 18 1.88 7.9 389 141 19.0 0.97 19 1.86 7.8 385 139 17.5 0.94 20 1.82 7.6 374 135
59 19.3 0.90 16 1.86 7.8 385 139 18.7 0.86 17 1.85 7.7 382 138 17.3 0.83 17 1.80 7.5 370 134 20.2 0.91 17 1.92 8.0 419 150 19.6 0.87 18 1.91 8.0 415 148 18.1 0.84 18 1.86 7.8 402 144
63 20.0 0.75 14 1.91 8.0 415 148 19.4 0.72 15 1.89 7.9 411 147 17.9 0.69 15 1.84 7.7 398 142 21.8 0.69 14 1.99 8.3 442 164 21.2 0.66 15 1.97 8.2 438 162 19.6 0.64 15 1.92 8.0 425 157
67 21.9 0.52 11 1.97 8.2 438 162 21.2 0.50 11 1.95 8.2 434 160 19.6 0.48 11 1.90 7.9 421 156
115ºF
23.4 0.44 10 2.05 8.6 461 174 22.7 0.42 10 2.04 8.5 457 173 21.0 0.41 10 1.98 8.3 443 167
71 -
kW = Total system power Amps = outdoor unit amps (compressor + fan)
23.6 0.69 15 1.92 7.9 400 158 22.9 0.65 16 1.90 7.8 396 157 21.1 0.63 16 1.85 7.6 385 152
67 23.6 0.52 11 1.90 7.8 396 157 22.9 0.49 12 1.89 7.7 392 155 21.1 0.47 12 1.84 7.5 381 150
105ºF
Expanded Cooling Data — SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1
SS-SSZ16
SS-SSZ16
www.goodmanmfg.com
24.8 1.00 23 1.47 5.7 220 115 24.0 0.98 25 1.46 5.7 218 114 22.2 0.94 25 1.43 5.5 211 110
MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR
766
875
984
59 24.3 1.00 23 1.46 5.7 218 114 23.6 0.93 23 1.45 5.6 216 113 21.8 0.90 23 1.42 5.5 209 109
Airflow MBh S/T ∆T kW 984 Amps Hi PR Lo PR MBh S/T ∆T kW 875 Amps Hi PR Lo PR MBh S/T ∆T 766 kW Amps Hi PR Lo PR
25.2 0.99 23 1.50 5.9 237 122 24.5 0.94 24 1.49 5.8 234 121 22.6 0.91 25 1.46 5.7 227 117
63 24.9 0.91 21 1.49 5.8 234 121 24.1 0.87 22 1.48 5.8 232 120 22.3 0.84 23 1.45 5.6 225 116 26.4 0.89 22 1.55 6.0 250 134 25.7 0.85 23 1.54 6.0 247 132 23.7 0.82 23 1.50 5.8 240 128
67 26.6 0.74 18 1.54 6.0 247 132 25.8 0.71 19 1.53 5.9 245 131 23.8 0.68 20 1.49 5.8 238 127 28.2 0.72 19 1.60 6.3 261 142 27.4 0.69 20 1.59 6.2 258 141 25.3 0.66 20 1.55 6.0 250 137
71 28.4 0.56 15 1.59 6.2 258 141 27.6 0.53 15 1.58 6.2 255 139 25.5 0.51 16 1.54 6.0 248 135 24.2 1.00 23 1.59 6.2 247 121 23.5 1.00 25 1.57 6.1 244 120 21.7 0.97 25 1.54 6.0 237 117
59 23.8 1.00 22 1.57 6.1 244 120 23.1 0.96 23 1.56 6.1 242 119 21.3 0.93 24 1.52 5.9 235 115 24.7 1.00 23 1.62 6.3 265 129 23.9 0.97 25 1.61 6.3 263 128 22.1 0.94 25 1.57 6.1 255 124
63 24.3 0.95 22 1.61 6.3 263 128 23.6 0.90 22 1.59 6.2 260 127 21.8 0.87 23 1.56 6.0 252 123 25.8 0.92 22 1.67 6.5 280 141 25.1 0.88 23 1.66 6.5 278 140 23.1 0.85 24 1.62 6.3 269 135
67 26.0 0.77 19 1.66 6.5 278 140 25.2 0.74 19 1.64 6.4 275 138 23.3 0.71 20 1.60 6.2 267 134
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
27.6 0.75 19 1.73 6.7 292 150 26.8 0.71 20 1.71 6.7 289 149 24.7 0.69 20 1.67 6.5 281 144
71 27.7 0.58 15 1.71 6.7 289 149 26.9 0.55 16 1.70 6.6 287 147 24.9 0.53 16 1.66 6.5 278 143 23.6 1.00 22 1.69 6.7 281 126 22.9 1.00 24 1.67 6.6 278 125 21.2 1.00 25 1.63 6.5 269 121
59 23.2 1.00 22 1.67 6.6 278 125 22.5 0.99 23 1.66 6.6 275 124 20.8 0.95 24 1.62 6.4 267 120 24.1 1.00 22 1.72 6.8 302 134 23.4 1.00 25 1.71 6.8 299 133 21.6 0.96 25 1.67 6.6 290 129
25.2 0.95 22 1.78 7.1 319 147 24.5 0.90 23 1.76 7.0 316 145 22.6 0.87 24 1.72 6.8 306 141
23.0 1.00 22 1.77 7.1 320 133 22.4 1.00 24 1.76 7.1 316 131 20.6 1.00 25 1.72 6.9 307 127
23.5 1.00 22 1.81 7.3 344 141 22.8 1.00 24 1.80 7.2 340 140 21.0 1.00 25 1.75 7.0 330 135
24.6 0.98 22 1.87 7.5 363 154 23.9 0.93 23 1.86 7.5 360 152 22.0 0.90 24 1.81 7.3 349 148
26.2 0.79 19 1.93 7.8 379 164 25.5 0.76 20 1.92 7.7 375 162 23.5 0.73 21 1.87 7.5 364 157
71 26.4 0.61 15 1.92 7.7 375 162 25.7 0.58 16 1.90 7.7 371 161 23.7 0.56 16 1.85 7.5 360 156
Shaded area reflects AHRI (TVA) conditions
26.9 0.77 19 1.84 7.3 333 156 26.1 0.73 20 1.82 7.2 329 155 24.1 0.71 20 1.78 7.1 319 150
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.7 25.3 27.1 22.6 23.1 24.7 1.00 0.79 0.59 1.00 1.00 0.82 22 19 15 21 22 19 1.71 1.76 1.82 1.76 1.80 1.86 6.8 7.0 7.2 7.1 7.2 7.5 299 316 329 316 340 360 133 145 155 131 140 152 23.0 24.6 26.3 22.0 22.5 24.0 0.93 0.75 0.56 1.00 0.96 0.78 22 20 16 23 23 20 1.69 1.75 1.81 1.74 1.78 1.84 6.7 6.9 7.2 7.0 7.2 7.4 296 313 326 313 337 356 132 144 153 130 138 151 21.3 22.7 24.3 20.3 20.7 22.2 0.89 0.73 0.54 0.98 0.92 0.75 23 20 16 24 23 20 1.65 1.71 1.76 1.70 1.74 1.79 6.5 6.8 7.0 6.8 7.0 7.2 287 303 316 304 327 345 128 139 148 126 134 146 21.9 1.00 20 1.85 7.6 359 139 21.2 1.00 22 1.83 7.5 356 138 19.6 1.00 24 1.79 7.3 345 133
59 21.5 1.00 20 1.83 7.5 356 138 20.9 1.00 22 1.82 7.4 352 136 19.3 1.02 24 1.77 7.2 342 132 22.3 1.00 21 1.89 7.7 387 148 21.7 1.00 23 1.87 7.7 383 146 20.0 1.00 24 1.83 7.5 372 142
63 22.0 1.00 21 1.87 7.7 383 146 21.3 0.99 22 1.86 7.6 379 145 19.7 0.96 23 1.81 7.4 368 141 24.9 0.82 19 2.02 8.3 426 172 24.2 0.78 20 2.00 8.2 422 170 22.3 0.76 20 1.95 8.0 409 165
71 25.1 0.63 15 2.00 8.2 422 170 24.4 0.60 15 1.98 8.1 418 168 22.5 0.58 16 1.93 7.9 405 163 20.3 1.00 19 1.91 8.0 397 144 19.7 1.00 21 1.90 7.9 393 142 18.2 1.00 22 1.85 7.7 381 138
59 19.9 1.00 19 1.90 7.9 393 142 19.3 1.00 20 1.88 7.9 389 141 17.9 1.03 22 1.83 7.6 378 137 20.7 1.00 19 1.95 8.2 427 153 20.1 1.00 21 1.94 8.1 423 151 18.5 1.00 22 1.89 7.9 410 147
63 20.4 1.00 19 1.94 8.1 423 151 19.8 1.00 21 1.92 8.0 419 150 18.2 0.97 21 1.87 7.8 406 145 21.6 1.00 20 2.02 8.5 451 167 21.0 0.97 22 2.00 8.4 447 165 19.4 0.94 22 1.95 8.2 433 160
67 21.8 0.85 17 2.00 8.4 447 165 21.1 0.82 18 1.99 8.3 442 164 19.5 0.79 18 1.94 8.1 429 159
115ºF
23.1 0.83 18 2.09 8.8 471 178 22.4 0.79 19 2.07 8.7 466 176 20.7 0.76 19 2.02 8.5 452 171
71 23.3 0.64 14 2.07 8.7 466 176 22.6 0.61 14 2.05 8.6 461 174 20.8 0.59 15 2.00 8.4 448 169
kW = Total system power Amps = outdoor unit amps (compressor + fan)
23.4 1.00 22 1.95 8.0 408 161 22.7 0.97 23 1.93 7.9 404 160 20.9 0.93 23 1.89 7.7 392 155
67 23.5 0.85 19 1.93 7.9 404 160 22.8 0.81 19 1.92 7.9 400 158 21.0 0.78 20 1.87 7.6 388 153
105ºF
Expanded Cooling Data — SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1 (cont.)
5
6
www.goodmanmfg.com
59 33.9 0.76 18 1.98 7.7 217 108 32.9 0.72 18 1.97 7.7 214 107 30.4 0.70 19 1.92 7.4 208 104
34.5 0.86 20 2.00 7.8 219 109 33.5 0.82 21 1.98 7.7 217 108 30.9 0.79 21 1.94 7.5 210 105
Airflow MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR
MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR
35.5 0.77 19 2.04 8.0 235 116 34.5 0.74 19 2.03 7.9 233 115 31.8 0.71 20 1.98 7.7 226 112
63 35.1 0.63 15 2.03 7.9 233 115 34.1 0.60 16 2.01 7.8 231 114 31.5 0.58 16 1.96 7.6 224 111 38.4 0.58 15 2.11 8.2 249 127 37.3 0.56 16 2.09 8.2 246 126 34.4 0.54 16 2.04 7.9 239 122
67 38.5 0.44 12 2.09 8.2 246 126 37.4 0.42 12 2.07 8.1 244 124 34.5 0.40 12 2.02 7.9 236 121 41.2 0.38 11 2.18 8.5 259 135 40.0 0.36 11 2.16 8.5 257 134 37.0 0.35 11 2.11 8.2 249 130
71 33.7 0.89 21 2.16 8.4 245 115 32.7 0.85 21 2.14 8.3 243 114 30.2 0.82 22 2.09 8.1 236 111
59 33.1 0.79 18 2.14 8.3 243 114 32.2 0.75 18 2.12 8.3 241 113 29.7 0.72 19 2.07 8.0 233 110 34.7 0.80 19 2.20 8.6 264 123 33.7 0.76 20 2.19 8.5 261 122 31.1 0.74 20 2.13 8.3 254 118
63 34.3 0.66 15 2.19 8.5 261 122 33.3 0.63 16 2.17 8.5 259 120 30.8 0.60 16 2.11 8.2 251 117 37.5 0.61 15 2.28 8.9 279 134 36.4 0.58 16 2.26 8.8 276 133 33.6 0.56 16 2.20 8.6 268 129
67 37.6 0.46 12 2.26 8.8 276 133 36.5 0.43 12 2.24 8.7 273 131 33.7 0.42 12 2.18 8.5 265 127
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
40.3 0.39 11 2.35 9.2 291 143 39.1 0.37 11 2.33 9.1 288 141 36.1 0.36 11 2.27 8.9 279 137
71 32.9 0.92 21 2.29 9.1 279 120 31.9 0.87 21 2.28 9.0 276 119 29.5 0.84 22 2.22 8.8 268 115
59 32.3 0.81 18 2.28 9.0 276 119 31.4 0.77 19 2.26 9.0 274 118 29.0 0.74 19 2.20 8.7 265 114 33.8 0.82 19 2.35 9.3 300 128 32.9 0.78 20 2.33 9.3 297 126 30.3 0.75 20 2.27 9.0 288 123
36.6 0.62 15 2.42 9.6 317 139 35.6 0.59 16 2.40 9.6 314 138 32.8 0.57 16 2.34 9.3 305 134
32.1 0.95 21 2.42 9.7 318 126 31.1 0.90 22 2.40 9.6 315 125 28.7 0.87 22 2.34 9.4 305 121
33.0 0.85 19 2.47 10.0 342 134 32.1 0.81 20 2.45 9.9 339 133 29.6 0.78 20 2.39 9.6 329 129
35.7 0.64 16 2.55 10.3 361 146 34.7 0.61 16 2.53 10.2 358 145 32.0 0.59 17 2.47 9.9 347 141
38.4 0.41 11 2.64 10.7 377 156 37.2 0.39 11 2.62 10.6 373 154 34.4 0.38 11 2.55 10.3 362 150
71 -
Shaded area reflects ACCA (TVA) conditions
39.3 0.40 11 2.51 10.0 331 148 38.2 0.38 11 2.48 9.9 328 147 35.2 0.37 11 2.42 9.6 318 143
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 33.5 36.7 31.5 32.7 35.8 0.67 0.47 0.83 0.70 0.48 15 12 18 15 12 2.33 2.40 2.40 2.45 2.53 9.3 9.6 9.6 9.9 10.2 297 314 315 339 358 126 138 125 133 145 32.5 35.6 30.6 31.7 34.8 0.64 0.45 0.79 0.66 0.46 16 12 19 16 12 2.31 2.38 2.38 2.43 2.51 9.2 9.5 9.6 9.8 10.1 294 311 312 335 354 125 137 124 131 143 30.0 32.9 28.3 29.3 32.1 0.62 0.43 0.77 0.64 0.44 16 12 19 16 12 2.25 2.32 2.32 2.37 2.45 8.9 9.2 9.3 9.5 9.8 286 302 302 325 343 121 132 120 127 139 30.5 0.98 20 2.52 10.4 358 132 29.6 0.94 21 2.50 10.3 354 131 27.3 0.90 22 2.44 10.0 343 127
59 30.0 0.86 18 2.50 10.3 354 131 29.1 0.82 18 2.48 10.2 351 129 26.9 0.79 19 2.42 9.9 340 126 31.4 0.88 19 2.58 10.6 385 141 30.5 0.84 20 2.56 10.5 381 139 28.1 0.81 20 2.49 10.2 370 135
63 31.1 0.72 15 2.56 10.5 381 139 30.2 0.69 16 2.53 10.4 377 138 27.8 0.66 16 2.47 10.1 366 134 36.4 0.43 11 2.76 11.4 424 163 35.4 0.41 11 2.73 11.3 420 162 32.7 0.39 11 2.66 11.0 407 157
71 28.2 0.99 19 2.61 11.0 395 137 27.4 0.94 20 2.59 10.9 391 135 25.3 0.91 20 2.52 10.6 380 131
59 27.8 0.87 16 2.59 10.9 391 135 26.9 0.83 17 2.57 10.8 387 134 24.9 0.80 17 2.50 10.5 376 130 29.1 0.89 18 2.67 11.2 425 145 28.2 0.85 18 2.65 11.1 421 144 26.0 0.81 19 2.58 10.8 408 140
63 28.8 0.73 14 2.65 11.1 421 144 27.9 0.69 15 2.62 11.0 417 142 25.8 0.67 15 2.56 10.7 404 138 31.5 0.67 14 2.76 11.6 449 159 30.5 0.64 15 2.74 11.5 445 157 28.2 0.62 15 2.67 11.2 431 152
67 31.5 0.50 11 2.74 11.5 445 157 30.6 0.48 11 2.71 11.4 440 156 28.2 0.46 11 2.64 11.1 427 151
115ºF
33.8 0.43 10 2.86 12.0 468 169 32.8 0.41 10 2.83 11.9 464 167 30.3 0.40 11 2.76 11.6 450 162
71 -
kW = Total system power Amps = outdoor unit amps (compressor + fan)
34.0 0.67 15 2.66 11.0 406 153 33.0 0.63 16 2.64 10.9 402 152 30.4 0.61 16 2.57 10.6 390 147
67 34.0 0.50 12 2.64 10.9 402 152 33.0 0.48 12 2.62 10.8 398 150 30.5 0.46 12 2.55 10.5 386 146
105ºF
Expanded Cooling Data — SSZ160361A* / CA*F4860*6A* + TXV / MBVC2000A*-1
SS-SSZ16
SS-SSZ16
www.goodmanmfg.com
59 35.1 0.95 23 2.02 7.9 221 110 34.1 0.90 24 2.00 7.8 219 109 31.4 0.87 24 1.95 7.6 212 106
63 35.9 0.89 22 2.06 8.0 238 117 34.8 0.85 23 2.04 8.0 235 116 32.1 0.82 23 1.99 7.8 228 113
67 38.3 0.72 19 2.13 8.3 251 128 37.2 0.69 20 2.11 8.2 249 127 34.3 0.66 20 2.06 8.0 241 123
71 41.0 0.54 15 2.20 8.6 262 137 39.8 0.51 16 2.18 8.5 259 135 36.7 0.50 16 2.12 8.3 251 131
59 34.3 1.00 23 2.17 8.5 248 117 33.3 0.94 24 2.16 8.4 245 115 30.7 0.90 24 2.10 8.2 238 112
63 35.0 0.92 22 2.22 8.7 267 124 34.0 0.88 23 2.20 8.6 264 123 31.4 0.85 23 2.15 8.4 256 119
67 37.4 0.75 19 2.29 9.0 282 135 36.3 0.71 20 2.28 8.9 279 134 33.5 0.69 20 2.22 8.6 271 130
71 40.0 0.56 15 2.37 9.3 294 144 38.8 0.53 16 2.35 9.2 291 143 35.8 0.51 16 2.29 9.0 282 139
59 33.5 1.00 23 2.31 9.2 282 121 32.5 0.96 24 2.30 9.1 279 120 30.0 0.92 24 2.24 8.9 271 116
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.0 32.6 33.4 35.6 0.94 0.77 0.57 1.00 1.00 0.79 22 19 15 22 23 19 2.37 2.44 2.53 2.44 2.49 2.58 9.4 9.7 10.1 9.8 10.1 10.4 303 320 334 321 346 365 129 141 150 127 135 148 33.2 35.5 37.9 31.7 32.4 34.6 0.90 0.73 0.55 0.99 0.93 0.76 23 20 16 24 23 20 2.35 2.42 2.51 2.42 2.47 2.55 9.3 9.6 10.0 9.7 10.0 10.3 300 317 331 318 342 361 128 139 148 126 134 146 30.6 32.7 35.0 29.3 29.9 31.9 0.87 0.71 0.53 0.95 0.90 0.73 23 20 16 24 23 20 2.29 2.36 2.44 2.36 2.41 2.49 9.1 9.4 9.7 9.5 9.7 10.0 291 308 321 308 332 350 124 135 144 122 130 142 71 38.1 0.59 15 2.66 10.8 381 157 37.0 0.56 16 2.64 10.7 377 156 34.1 0.54 16 2.57 10.4 366 151
59 31.0 1.00 21 2.54 10.4 361 133 30.1 1.00 23 2.52 10.4 358 132 27.8 0.99 24 2.46 10.1 347 128
63 31.7 1.00 22 2.60 10.7 389 142 30.8 0.96 23 2.58 10.6 385 141 28.4 0.93 23 2.51 10.3 373 136
67 33.9 0.82 19 2.69 11.1 411 155 32.9 0.78 20 2.66 11.0 406 153 30.3 0.76 20 2.60 10.7 394 149
105ºF 71 36.2 0.61 15 2.78 11.5 428 165 35.1 0.59 16 2.76 11.4 424 163 32.4 0.57 16 2.68 11.1 411 158
59 28.7 1.00 20 2.63 11.1 399 138 27.9 1.00 21 2.61 11.0 395 137 25.7 1.00 23 2.54 10.7 383 133
63 29.4 1.00 20 2.69 11.3 430 147 28.5 0.97 21 2.67 11.2 425 145 26.3 0.94 22 2.60 10.9 413 141
67 31.4 0.83 18 2.78 11.7 454 160 30.4 0.79 18 2.76 11.6 449 159 28.1 0.76 19 2.69 11.3 436 154
115ºF 71 33.5 0.62 14 2.88 12.2 473 171 32.5 0.59 15 2.86 12.0 468 169 30.0 0.57 15 2.78 11.7 454 164
Shaded area reflects AHRI (TVA) conditions
kW = Total system power Amps = outdoor unit amps (compressor + fan)
MBh 35.71 36.40 38.12 40.67 34.88 35.55 37.23 39.72 34.04 34.70 36.35 38.78 33.21 33.86 35.46 37.83 31.55 32.16 33.69 35.94 29.23 29.79 31.20 33.29 S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80 ∆T 24 24 22 19 24 24 23 20 23 24 23 20 23 23 23 20 21 22 23 20 20 20 21 18 2.03 2.08 2.14 2.21 2.19 2.24 2.31 2.39 2.33 2.39 2.46 2.55 2.46 2.51 2.60 2.69 2.56 2.62 2.71 2.80 2.66 2.72 2.81 2.91 1350 kW Amps 7.9 8.1 8.4 8.7 8.6 8.8 9.0 9.4 9.3 9.5 9.8 10.2 9.9 10.2 10.5 10.9 10.5 10.8 11.2 11.6 11.2 11.4 11.8 12.3 Hi PR 223 240 254 264 250 269 285 297 285 306 324 338 324 349 369 384 365 393 415 432 403 434 458 478 Lo PR 111 119 129 138 118 125 137 146 122 130 142 151 129 137 149 159 135 143 157 167 139 148 162 172 MBh 34.7 35.3 37.0 39.5 33.9 34.5 36.1 38.6 33.1 33.7 35.3 37.6 32.2 32.9 34.4 36.7 30.6 31.2 32.7 34.9 28.4 28.9 30.3 32.3 S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 ∆T 25 25 23 20 25 25 24 20 25 25 24 20 25 25 24 21 23 24 24 20 22 22 22 19 1200 kW 2.02 2.06 2.13 2.20 2.17 2.22 2.29 2.37 2.31 2.37 2.44 2.53 2.44 2.49 2.58 2.66 2.54 2.60 2.69 2.78 2.63 2.69 2.78 2.88 Amps 7.9 8.0 8.3 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.1 9.8 10.1 10.4 10.8 10.4 10.7 11.1 11.5 11.1 11.3 11.7 12.2 Hi PR 221 238 251 262 248 267 282 294 282 303 320 334 321 346 365 381 361 389 411 428 399 430 454 473 Lo PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171 MBh 32.0 32.6 34.2 36.4 31.3 31.9 33.4 35.6 30.5 31.1 32.6 34.7 29.8 30.3 31.8 33.9 28.3 28.8 30.2 32.2 26.2 26.7 28.0 29.8 S/T 0.91 0.88 0.79 0.64 0.95 0.91 0.82 0.67 0.97 0.94 0.84 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74 ∆T 26 25 24 21 26 25 24 21 26 25 24 21 26 26 24 21 25 25 24 21 23 23 22 19 1.97 2.01 2.07 2.14 2.12 2.17 2.24 2.31 2.26 2.31 2.38 2.46 2.38 2.43 2.51 2.60 2.48 2.53 2.62 2.71 2.57 2.62 2.71 2.81 1050 kW Amps 7.6 7.8 8.1 8.4 8.3 8.4 8.7 9.0 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.5 10.2 10.4 10.8 11.2 10.8 11.0 11.4 11.8 Hi PR 214 231 244 254 240 259 273 285 273 294 311 324 311 335 354 369 350 377 398 415 387 417 440 459 Lo PR 107 114 124 132 113 120 131 140 118 125 137 145 123 131 143 153 129 138 150 160 134 142 155 166
Airflow MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
Expanded Cooling Data — SSZ160361A* / CA*F4860*6A* + TXV / MBVC2000A*-1 (cont.)
7
8
www.goodmanmfg.com
59 46.5 0.77 19 2.68 10.2 213 110 45.2 0.74 20 2.66 10.1 211 109 41.7 0.71 20 2.60 9.8 204 106
47.3 0.88 22 2.70 10.3 215 111 46.0 0.84 23 2.68 10.2 213 110 42.4 0.81 23 2.62 9.9 206 107
Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR
MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR
48.7 0.78 20 2.76 10.5 231 118 47.3 0.75 21 2.73 10.4 229 117 43.7 0.72 21 2.67 10.1 222 113
63 48.2 0.64 16 2.73 10.4 229 117 46.8 0.61 17 2.71 10.3 227 116 43.2 0.59 17 2.65 10.0 220 112 52.8 0.59 17 2.84 10.9 244 129 51.2 0.57 17 2.82 10.8 242 128 47.3 0.55 18 2.75 10.5 235 124
67 52.9 0.45 12 2.82 10.8 242 128 51.3 0.43 13 2.80 10.7 239 126 47.4 0.41 13 2.73 10.4 232 123 56.6 0.38 11 2.93 11.3 255 137 55.0 0.36 12 2.91 11.2 252 136 50.7 0.35 12 2.84 10.9 245 132
71 46.2 0.91 22 2.90 11.1 241 117 44.9 0.87 23 2.88 11.0 239 116 41.4 0.84 23 2.81 10.7 232 113
59 45.5 0.80 19 2.88 11.0 239 116 44.1 0.76 20 2.86 10.9 236 115 40.7 0.74 20 2.79 10.6 229 112 47.6 0.81 20 2.97 11.4 260 125 46.2 0.78 21 2.94 11.3 257 124 42.7 0.75 22 2.87 11.0 249 120
63 47.1 0.67 17 2.94 11.3 257 124 45.7 0.64 17 2.92 11.2 254 122 42.2 0.61 18 2.85 10.9 247 119 51.5 0.62 17 3.06 11.7 274 136 50.0 0.59 17 3.04 11.6 271 135 46.2 0.57 18 2.96 11.3 263 131
67 51.6 0.46 13 3.04 11.6 271 135 50.1 0.44 13 3.01 11.5 269 134 46.3 0.43 13 2.94 11.2 261 130
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
55.3 0.40 12 3.16 12.2 286 145 53.7 0.38 12 3.13 12.1 283 144 49.6 0.36 12 3.06 11.7 275 139
71 45.1 0.93 22 3.09 12.1 274 122 43.8 0.89 23 3.06 11.9 272 121 40.4 0.86 24 2.99 11.6 263 117
59 44.4 0.82 19 3.06 11.9 272 121 43.1 0.78 20 3.04 11.8 269 119 39.8 0.75 20 2.96 11.5 261 116 46.5 0.83 20 3.15 12.4 295 130 45.1 0.80 21 3.13 12.2 292 128 41.6 0.77 22 3.05 11.9 284 125
50.3 0.63 17 3.25 12.8 312 142 48.8 0.60 17 3.23 12.6 309 140 45.1 0.58 18 3.15 12.3 299 136
44.0 0.96 22 3.25 12.9 312 128 42.8 0.92 23 3.22 12.8 309 127 39.5 0.89 24 3.14 12.4 300 123
45.3 0.86 21 3.32 13.2 336 136 44.0 0.82 21 3.29 13.1 333 135 40.6 0.79 22 3.21 12.7 323 131
49.1 0.65 17 3.42 13.6 355 149 47.6 0.62 18 3.40 13.5 352 147 44.0 0.60 18 3.31 13.1 341 143
52.7 0.42 12 3.54 14.2 370 158 51.1 0.40 12 3.51 14.0 367 157 47.2 0.39 12 3.42 13.6 356 152
71 -
Shaded area reflects ACCA (TVA) conditions
54.0 0.41 12 3.36 13.2 325 151 52.4 0.39 12 3.33 13.1 322 149 48.4 0.37 12 3.25 12.8 312 145
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.0 50.4 43.3 44.9 49.2 0.69 0.47 0.85 0.71 0.49 17 13 19 17 13 3.13 3.23 3.22 3.29 3.40 12.2 12.6 12.8 13.1 13.5 292 309 309 333 351 128 140 127 135 147 44.7 48.9 42.0 43.6 47.7 0.65 0.45 0.81 0.67 0.47 17 13 20 17 13 3.10 3.20 3.19 3.26 3.37 12.1 12.5 12.7 13.0 13.4 289 306 306 330 348 127 139 126 134 146 41.2 45.2 38.8 40.2 44.1 0.63 0.44 0.78 0.65 0.45 18 13 20 18 13 3.03 3.12 3.11 3.18 3.28 11.8 12.2 12.3 12.6 13.0 281 296 297 320 338 123 135 122 130 141 41.8 1.00 22 3.38 13.7 352 134 40.6 0.95 23 3.35 13.6 348 133 37.5 0.92 23 3.27 13.2 338 129
59 41.1 0.88 19 3.35 13.6 348 133 39.9 0.84 20 3.33 13.5 345 132 36.9 0.81 20 3.24 13.1 334 128 43.1 0.89 20 3.46 14.1 378 143 41.8 0.85 21 3.43 13.9 375 141 38.6 0.82 21 3.34 13.5 363 137
63 42.6 0.73 16 3.43 13.9 374 141 41.4 0.70 17 3.40 13.8 371 140 38.2 0.67 17 3.31 13.4 360 136 50.0 0.44 11 3.69 15.1 417 166 48.6 0.41 12 3.66 14.9 412 164 44.8 0.40 12 3.57 14.5 400 159
71 38.7 1.00 20 3.50 14.5 388 139 37.6 0.96 21 3.47 14.4 385 137 34.7 0.93 22 3.38 14.0 373 133
59 38.1 0.89 18 3.47 14.4 384 137 37.0 0.85 19 3.44 14.3 381 136 34.1 0.81 19 3.35 13.9 369 132 39.9 0.90 19 3.58 14.9 418 148 38.7 0.86 20 3.55 14.8 414 146 35.8 0.83 20 3.46 14.3 401 142
63 39.5 0.74 15 3.55 14.8 414 146 38.3 0.71 16 3.52 14.6 410 145 35.4 0.68 16 3.43 14.2 397 140 43.2 0.68 16 3.69 15.4 441 161 41.9 0.65 16 3.66 15.3 437 160 38.7 0.63 16 3.57 14.8 424 155
67 43.3 0.51 12 3.66 15.3 437 160 42.0 0.49 12 3.63 15.1 433 158 38.8 0.47 12 3.54 14.7 420 153
115ºF
46.3 0.44 11 3.82 16.0 460 172 45.0 0.42 11 3.79 15.8 456 170 41.5 0.40 11 3.69 15.4 442 165
71 -
kW = Total system power Amps = outdoor unit amps (compressor + fan)
46.6 0.68 17 3.57 14.5 399 156 45.3 0.64 17 3.54 14.4 395 154 41.8 0.62 18 3.45 14.0 384 150
67 46.7 0.51 13 3.54 14.4 395 154 45.4 0.48 13 3.51 14.3 391 153 41.9 0.47 13 3.42 13.9 380 148
105ºF
Expanded Cooling Data — SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1
SS-SSZ16
SS-SSZ16
www.goodmanmfg.com
59 48.2 0.96 24 2.72 10.4 217 112 46.8 0.92 25 2.70 10.3 215 111 43.2 0.88 26 2.64 10.0 209 108
49.0 1.00 26 2.74 10.5 219 113 47.6 0.96 27 2.72 10.4 217 112 43.9 0.93 28 2.66 10.1 211 109
Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR
MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR
50.0 0.97 26 2.80 10.7 236 121 48.5 0.93 27 2.78 10.6 234 119 44.8 0.90 27 2.71 10.3 227 116
63 49.2 0.90 23 2.78 10.6 234 119 47.8 0.86 24 2.76 10.5 231 118 44.1 0.83 25 2.69 10.2 224 115 52.3 0.88 24 2.89 11.1 249 132 50.8 0.84 25 2.87 11.0 247 130 46.9 0.81 26 2.80 10.7 239 126
67 52.6 0.73 20 2.87 11.0 247 130 51.1 0.70 21 2.84 10.9 244 129 47.1 0.68 22 2.77 10.6 237 125 55.8 0.71 21 2.98 11.5 260 140 54.2 0.68 22 2.96 11.4 257 139 50.0 0.66 22 2.89 11.1 250 135
71 56.2 0.55 16 2.96 11.4 257 139 54.6 0.52 17 2.93 11.3 255 137 50.4 0.50 17 2.86 11.0 247 133 47.9 1.00 25 2.95 11.3 246 120 46.5 1.00 27 2.93 11.2 244 118 42.9 0.96 28 2.86 10.9 236 115
59 47.1 1.00 25 2.93 11.2 244 118 45.7 0.95 26 2.91 11.1 241 117 42.2 0.92 26 2.84 10.8 234 114 48.8 1.00 26 3.02 11.6 265 127 47.4 0.96 27 2.99 11.5 262 126 43.7 0.93 28 2.92 11.2 254 122
63 48.1 0.94 24 2.99 11.5 262 126 46.7 0.89 25 2.97 11.4 260 125 43.1 0.86 25 2.90 11.1 252 121 51.1 0.91 25 3.11 12.0 280 139 49.6 0.87 26 3.09 11.8 277 138 45.8 0.84 26 3.01 11.5 269 133
67 51.4 0.76 21 3.09 11.8 277 138 49.9 0.73 21 3.06 11.7 274 136 46.0 0.70 22 2.99 11.4 266 132
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
54.5 0.74 21 3.21 12.4 292 148 52.9 0.70 22 3.19 12.3 289 147 48.9 0.68 22 3.11 12.0 280 142
71 54.9 0.57 16 3.19 12.3 289 147 53.3 0.54 17 3.16 12.2 286 145 49.2 0.52 17 3.08 11.8 277 141 46.7 1.00 25 3.14 12.3 280 124 45.4 1.00 27 3.11 12.2 277 123 41.9 0.99 28 3.04 11.8 269 119
59 45.9 1.00 24 3.11 12.2 277 123 44.6 0.98 26 3.09 12.1 274 122 41.2 0.94 26 3.01 11.7 266 118 47.6 1.00 25 3.20 12.6 301 132 46.3 0.99 27 3.18 12.5 298 131 42.7 0.95 28 3.10 12.1 289 127
49.9 0.93 25 3.31 13.0 318 144 48.4 0.89 26 3.28 12.9 315 143 44.7 0.86 26 3.20 12.5 305 139
45.6 1.00 24 3.30 13.1 319 131 44.3 1.00 26 3.27 13.0 316 129 40.9 1.00 28 3.19 12.6 306 125
46.5 1.00 25 3.37 13.4 343 139 45.1 1.00 27 3.34 13.3 340 138 41.7 0.98 28 3.26 13.0 329 133
48.7 0.96 25 3.48 13.9 362 152 47.3 0.92 26 3.45 13.8 359 150 43.6 0.89 26 3.37 13.4 348 146
51.9 0.78 21 3.60 14.4 378 162 50.4 0.75 22 3.57 14.3 374 160 46.5 0.72 23 3.48 13.9 363 155
71 52.3 0.60 17 3.57 14.3 374 160 50.8 0.57 17 3.54 14.2 370 158 46.9 0.55 18 3.45 13.8 359 154
Shaded area reflects AHRI (TVA) conditions
53.2 0.76 21 3.42 13.5 332 154 51.7 0.72 22 3.39 13.4 328 152 47.7 0.70 23 3.30 13.0 319 148
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.9 50.1 53.6 44.8 45.8 48.9 0.96 0.78 0.58 1.00 1.00 0.81 24 21 16 24 24 21 3.18 3.28 3.39 3.27 3.34 3.45 12.5 12.9 13.4 13.0 13.3 13.8 298 315 328 316 340 359 131 143 152 129 138 150 45.6 48.7 52.0 43.5 44.5 47.5 0.91 0.74 0.56 1.00 0.94 0.77 25 21 17 26 25 22 3.15 3.25 3.36 3.25 3.32 3.43 12.4 12.8 13.2 12.9 13.2 13.6 295 312 325 312 336 355 130 142 151 128 136 149 42.1 44.9 48.0 40.2 41.0 43.8 0.88 0.72 0.54 0.97 0.91 0.74 25 22 17 26 25 22 3.08 3.17 3.28 3.17 3.24 3.34 12.0 12.4 12.9 12.5 12.8 13.3 286 302 315 303 326 344 126 137 146 124 132 144 43.3 1.00 23 3.44 14.0 359 137 42.1 1.00 25 3.41 13.8 355 136 38.8 1.00 26 3.32 13.5 344 131
59 42.6 1.00 22 3.41 13.8 355 136 41.3 1.00 25 3.38 13.7 352 134 38.2 1.01 26 3.30 13.3 341 130 44.2 1.00 23 3.51 14.3 386 146 42.9 1.00 25 3.49 14.2 382 144 39.6 1.00 27 3.40 13.8 371 140
63 43.5 1.00 23 3.49 14.2 382 144 42.2 0.98 25 3.46 14.1 378 143 39.0 0.94 25 3.37 13.7 367 139 49.3 0.81 21 3.75 15.4 425 169 47.9 0.77 22 3.72 15.2 421 168 44.2 0.75 22 3.63 14.8 408 163
71 49.7 0.63 16 3.72 15.2 421 168 48.2 0.60 17 3.69 15.1 417 166 44.5 0.57 17 3.60 14.7 404 161 40.1 1.00 21 3.56 14.8 396 142 39.0 1.00 23 3.53 14.7 392 140 36.0 1.00 24 3.44 14.3 381 136
59 39.4 1.00 21 3.53 14.7 392 140 38.3 1.00 23 3.50 14.5 388 139 35.3 1.02 24 3.41 14.1 377 135 40.9 1.00 22 3.64 15.2 426 151 39.7 1.00 24 3.61 15.0 422 149 36.7 1.00 25 3.52 14.6 410 145
63 40.3 1.00 21 3.61 15.0 422 149 39.1 0.99 23 3.58 14.9 418 148 36.1 0.95 23 3.49 14.5 405 143 42.8 1.00 23 3.76 15.7 450 164 41.6 0.96 24 3.73 15.5 446 163 38.4 0.93 24 3.63 15.1 432 158
67 43.1 0.84 19 3.73 15.5 446 163 41.8 0.80 20 3.69 15.4 441 161 38.6 0.78 20 3.60 15.0 428 156
115ºF
45.7 0.82 20 3.88 16.3 470 175 44.4 0.78 21 3.85 16.1 465 173 41.0 0.75 21 3.75 15.7 451 168
71 46.0 0.63 15 3.85 16.1 465 173 44.7 0.60 16 3.82 16.0 460 172 41.2 0.58 16 3.72 15.5 447 167
kW = Total system power Amps = outdoor unit amps (compressor + fan)
46.2 1.00 24 3.63 14.8 408 159 44.9 0.95 25 3.60 14.7 403 157 41.4 0.92 26 3.51 14.3 391 153
67 46.5 0.84 20 3.60 14.7 403 157 45.1 0.80 21 3.57 14.5 399 156 41.7 0.77 22 3.48 14.1 388 151
105ºF
Expanded Cooling Data — SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1 (cont.)
9
10
www.goodmanmfg.com
59 55.9 0.74 19 3.55 13.9 218 104 54.2 0.71 20 3.52 13.8 216 103 53.4 0.68 21 3.48 13.6 212 101
56.8 0.84 22 3.58 14.0 220 105 55.1 0.80 23 3.55 13.9 218 104 54.3 0.78 24 3.50 13.7 214 102
Airflow MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR
MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR
58.5 0.75 20 3.65 14.4 237 112 56.8 0.72 21 3.62 14.2 235 111 55.9 0.69 22 3.58 14.0 231 109
63 57.9 0.62 16 3.62 14.2 234 111 56.2 0.59 17 3.60 14.1 232 110 55.4 0.57 18 3.55 13.9 228 108 63.3 0.57 17 3.77 14.8 250 122 61.5 0.54 18 3.74 14.7 248 121 60.5 0.52 18 3.69 14.5 243 119
67 63.4 0.43 13 3.74 14.7 248 121 61.6 0.41 13 3.71 14.6 245 120 60.7 0.39 14 3.66 14.3 241 118 67.9 0.37 11 3.89 15.4 261 130 66.0 0.35 12 3.85 15.2 258 129 65.0 0.34 13 3.80 15.0 254 127
71 55.5 0.87 22 3.85 15.1 247 111 53.9 0.83 24 3.82 15.0 245 110 53.1 0.80 24 3.77 14.8 240 108
59 54.6 0.77 19 3.82 15.0 244 110 53.0 0.73 20 3.79 14.9 242 109 52.2 0.71 21 3.74 14.6 238 107 57.1 0.78 21 3.93 15.5 266 118 55.5 0.74 22 3.90 15.4 263 117 54.6 0.72 23 3.85 15.1 259 115
63 56.5 0.64 17 3.90 15.4 263 117 54.9 0.61 18 3.87 15.2 261 116 54.1 0.59 18 3.82 15.0 256 114 61.8 0.59 17 4.05 16.0 281 129 60.0 0.56 18 4.02 15.9 278 128 59.1 0.54 18 3.97 15.6 273 126
67 62.0 0.44 13 4.02 15.9 278 128 60.1 0.42 13 3.99 15.7 275 126 59.2 0.41 14 3.94 15.5 270 124
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
66.4 0.38 12 4.19 16.6 293 137 64.4 0.36 12 4.15 16.5 290 136 63.5 0.35 13 4.09 16.2 285 134
71 54.2 0.90 22 4.09 16.4 281 115 52.6 0.85 24 4.05 16.3 278 114 51.8 0.82 25 4.00 16.0 273 112
59 53.3 0.79 19 4.05 16.3 278 114 51.7 0.75 20 4.02 16.1 275 113 50.9 0.72 21 3.97 15.9 271 111 55.8 0.80 21 4.18 16.8 302 123 54.1 0.76 22 4.14 16.7 299 122 53.3 0.74 23 4.08 16.4 294 119
60.4 0.61 17 4.31 17.4 319 134 58.6 0.58 18 4.27 17.2 316 133 57.7 0.56 18 4.22 17.0 311 130
52.8 0.92 22 4.30 17.6 320 121 51.3 0.88 24 4.26 17.4 317 120 50.5 0.85 25 4.20 17.1 311 118
54.4 0.83 21 4.39 18.0 344 129 52.8 0.79 22 4.36 17.8 341 128 52.0 0.76 23 4.30 17.6 335 126
58.9 0.63 17 4.53 18.6 364 141 57.2 0.60 18 4.50 18.4 360 139 56.3 0.58 19 4.43 18.1 354 137
63.2 0.40 12 4.68 19.3 379 150 61.4 0.38 12 4.64 19.1 375 148 60.4 0.37 13 4.58 18.8 369 146
71 -
Shaded area reflects ACCA (TVA) conditions
64.8 0.39 12 4.45 18.1 333 143 62.9 0.37 12 4.41 17.9 330 141 62.0 0.36 13 4.35 17.6 324 139
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.81 0.68 0.47 17 13 19 17 13 4.14 4.27 4.26 4.36 4.50 16.7 17.2 17.4 17.8 18.4 299 316 317 341 360 122 133 120 128 139 53.6 58.7 50.4 52.3 57.3 0.63 0.43 0.78 0.65 0.45 18 13 21 18 14 4.11 4.24 4.23 4.32 4.46 16.5 17.1 17.3 17.7 18.3 296 313 314 337 356 120 131 119 126 138 52.8 57.8 49.7 51.5 56.4 0.61 0.42 0.75 0.62 0.43 18 14 21 18 14 4.05 4.18 4.17 4.26 4.40 16.3 16.8 17.0 17.4 18.0 291 308 308 332 350 118 129 117 124 136 50.2 0.96 22 4.48 18.7 360 127 48.7 0.91 23 4.44 18.5 356 126 48.0 0.88 24 4.38 18.2 350 124
59 49.4 0.84 19 4.44 18.5 356 126 47.9 0.80 20 4.40 18.4 353 125 47.2 0.78 21 4.34 18.1 347 122 51.7 0.86 20 4.58 19.2 387 135 50.2 0.82 22 4.54 19.0 383 134 49.4 0.79 22 4.47 18.7 377 132
63 51.2 0.70 17 4.54 19.0 383 134 49.7 0.67 18 4.50 18.8 380 132 48.9 0.65 18 4.44 18.5 373 130 60.0 0.42 12 4.88 20.5 427 157 58.3 0.40 12 4.84 20.4 422 156 57.4 0.38 13 4.77 20.0 415 153
71 46.5 0.97 21 4.63 19.8 398 131 45.1 0.92 22 4.59 19.6 394 130 44.5 0.89 23 4.53 19.3 387 128
59 45.7 0.85 18 4.59 19.6 394 130 44.4 0.81 19 4.55 19.4 390 129 43.7 0.78 20 4.49 19.1 383 127 47.9 0.87 19 4.73 20.3 428 140 46.5 0.83 20 4.69 20.1 424 138 45.8 0.80 21 4.63 19.8 417 136
63 47.4 0.71 15 4.69 20.1 424 138 46.0 0.68 16 4.65 19.9 419 137 45.3 0.65 17 4.59 19.6 412 135 51.8 0.65 16 4.89 21.0 452 153 50.3 0.62 17 4.85 20.8 447 151 49.6 0.60 17 4.78 20.5 440 149
67 51.9 0.49 12 4.85 20.8 447 151 50.4 0.47 12 4.81 20.6 443 150 49.7 0.45 13 4.74 20.3 435 147
115ºF
55.6 0.42 11 5.05 21.8 471 163 54.0 0.40 11 5.01 21.6 467 161 53.2 0.39 12 4.94 21.2 459 158
71 -
kW = Total system power Amps = outdoor unit amps (compressor + fan)
55.9 0.65 17 4.72 19.8 409 148 54.3 0.62 18 4.69 19.6 405 146 53.5 0.60 18 4.62 19.3 398 144
67 56.1 0.49 13 4.68 19.6 405 146 54.4 0.47 13 4.65 19.4 401 145 53.6 0.45 14 4.58 19.1 394 142
105ºF
Expanded Cooling Data — SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1
SS-SSZ16
SS-SSZ16
www.goodmanmfg.com
59 57.8 0.92 25 3.61 14.1 222 106 56.1 0.88 26 3.58 14.0 220 105 55.3 0.85 27 3.53 13.8 216 103
58.8 0.97 26 3.64 14.3 225 107 57.1 0.92 28 3.61 14.1 222 106 56.3 0.89 29 3.56 13.9 219 104
Airflow MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR
MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR
60.0 0.93 26 3.71 14.6 242 114 58.2 0.89 27 3.68 14.5 239 113 57.3 0.86 28 3.63 14.3 235 111
63 59.1 0.87 24 3.68 14.5 239 113 57.4 0.83 25 3.65 14.4 237 112 56.5 0.80 26 3.60 14.1 233 110 62.8 0.84 24 3.83 15.1 255 125 61.0 0.80 26 3.80 15.0 253 123 60.1 0.78 27 3.75 14.7 248 121
67 63.1 0.71 20 3.80 15.0 253 123 61.3 0.67 22 3.77 14.8 250 122 60.4 0.65 23 3.72 14.6 246 120 67.0 0.68 21 3.95 15.6 266 133 65.0 0.65 22 3.92 15.5 264 131 64.1 0.63 23 3.86 15.3 259 129
71 67.5 0.53 16 3.92 15.5 264 131 65.5 0.50 17 3.89 15.4 261 130 64.5 0.48 18 3.83 15.1 256 128 57.5 1.00 26 3.91 15.4 252 113 55.8 0.96 28 3.88 15.3 249 112 54.9 0.92 29 3.83 15.0 245 110
59 56.5 0.96 25 3.88 15.3 249 112 54.8 0.91 26 3.85 15.1 247 111 54.0 0.88 27 3.80 14.9 243 109 58.6 0.97 26 3.99 15.8 271 121 56.9 0.92 28 3.96 15.6 268 119 56.0 0.89 29 3.91 15.4 264 117
63 57.7 0.90 24 3.96 15.6 268 119 56.0 0.86 25 3.93 15.5 266 118 55.2 0.83 26 3.88 15.3 261 116 61.3 0.87 25 4.12 16.3 286 132 59.6 0.83 26 4.09 16.2 284 130 58.7 0.80 27 4.03 15.9 279 128
67 61.6 0.73 21 4.09 16.2 284 130 59.9 0.70 22 4.05 16.0 281 129 59.0 0.67 23 4.00 15.8 276 127
75ºF
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
65.4 0.71 21 4.25 16.9 299 140 63.5 0.68 23 4.22 16.8 296 139 62.6 0.65 23 4.16 16.5 291 136
71 65.9 0.55 17 4.22 16.8 296 139 64.0 0.52 18 4.19 16.6 293 137 63.0 0.50 18 4.13 16.4 288 135 56.1 1.00 26 4.15 16.7 287 118 54.5 0.98 28 4.12 16.6 284 117 53.6 0.95 29 4.06 16.3 279 115
59 55.1 1.00 25 4.12 16.6 284 117 53.5 0.94 26 4.09 16.4 281 115 52.7 0.90 27 4.03 16.2 276 113 57.2 0.99 26 4.24 17.2 308 125 55.5 0.95 28 4.21 17.0 305 124 54.7 0.91 29 4.15 16.7 300 122
59.9 0.90 25 4.38 17.7 326 137 58.1 0.86 26 4.34 17.6 322 135 57.3 0.82 27 4.28 17.3 317 133
54.7 1.00 25 4.37 17.9 326 124 53.1 1.00 28 4.33 17.7 323 122 52.3 0.98 29 4.27 17.5 318 120
55.8 1.00 26 4.46 18.3 351 132 54.2 0.98 28 4.43 18.2 348 130 53.3 0.94 29 4.37 17.9 342 128
58.4 0.93 25 4.61 18.9 371 144 56.7 0.88 26 4.57 18.8 367 142 55.9 0.85 27 4.51 18.5 361 140
62.3 0.75 22 4.76 19.7 387 153 60.5 0.72 23 4.72 19.5 383 151 59.6 0.69 24 4.66 19.2 377 149
71 62.8 0.58 17 4.72 19.5 383 151 60.9 0.55 18 4.68 19.3 379 150 60.0 0.53 18 4.62 19.0 373 147
Shaded area reflects AHRI (TVA) conditions
63.9 0.73 21 4.52 18.4 340 146 62.0 0.69 23 4.49 18.2 336 144 61.1 0.67 23 4.42 17.9 331 142
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.3 60.2 64.3 53.8 55.0 58.7 0.92 0.75 0.56 1.00 0.95 0.77 24 21 17 25 24 21 4.21 4.34 4.49 4.33 4.43 4.57 17.0 17.6 18.2 17.7 18.2 18.8 305 322 336 323 348 367 124 135 144 122 130 142 54.7 58.4 62.5 52.2 53.4 57.0 0.88 0.71 0.53 0.97 0.91 0.74 25 22 18 27 25 22 4.18 4.31 4.45 4.30 4.39 4.53 16.8 17.4 18.1 17.6 18.0 18.6 302 319 333 320 344 364 123 134 143 121 129 141 53.9 57.5 61.5 51.4 52.6 56.1 0.85 0.69 0.52 0.93 0.87 0.71 26 23 18 28 26 23 4.12 4.25 4.39 4.24 4.33 4.47 16.6 17.1 17.8 17.3 17.7 18.3 297 314 327 315 338 357 121 132 140 119 127 138 52.0 1.00 24 4.55 19.0 367 130 50.5 1.00 27 4.51 18.9 364 128 49.7 1.00 29 4.45 18.6 357 126
59 51.1 1.00 23 4.51 18.9 364 128 49.6 1.00 26 4.48 18.7 360 127 48.9 0.97 27 4.41 18.4 354 125 53.0 1.00 24 4.65 19.5 395 138 51.4 1.00 27 4.61 19.3 391 137 50.7 0.98 29 4.55 19.0 385 134
63 52.2 1.00 24 4.61 19.3 391 137 50.7 0.94 25 4.58 19.2 387 135 49.9 0.91 26 4.51 18.9 381 133 59.2 0.78 21 4.96 20.9 435 160 57.5 0.74 22 4.92 20.7 431 159 56.6 0.72 23 4.85 20.4 424 156
71 59.6 0.60 16 4.92 20.7 431 159 57.9 0.57 17 4.88 20.5 427 157 57.0 0.55 18 4.81 20.2 419 154 48.2 1.00 22 4.71 20.2 406 134 46.7 1.00 25 4.67 20.0 402 133 46.0 1.00 26 4.60 19.7 395 130
59 47.3 1.00 22 4.67 20.0 402 133 45.9 1.00 24 4.63 19.8 398 131 45.3 0.98 25 4.57 19.5 391 129 49.1 1.00 23 4.81 20.7 437 143 47.7 1.00 25 4.77 20.5 432 141 46.9 0.99 27 4.71 20.2 425 139
63 48.4 1.00 22 4.77 20.5 432 141 46.9 0.95 23 4.73 20.3 428 140 46.2 0.92 24 4.67 20.0 421 137 51.4 0.97 23 4.97 21.4 461 156 49.9 0.92 24 4.93 21.2 456 154 49.2 0.89 25 4.86 20.8 449 152
67 51.7 0.81 19 4.93 21.2 456 154 50.2 0.77 20 4.89 21.0 452 153 49.4 0.74 21 4.82 20.6 444 150
115ºF
54.8 0.79 20 5.14 22.2 481 166 53.2 0.75 21 5.10 22.0 476 164 52.4 0.72 22 5.02 21.6 468 161
71 55.2 0.61 15 5.10 22.0 476 164 53.6 0.58 16 5.05 21.8 471 163 52.8 0.56 17 4.98 21.4 463 160
kW = Total system power Amps = outdoor unit amps (compressor + fan)
55.5 0.96 25 4.80 20.2 417 151 53.9 0.92 26 4.76 20.0 413 149 53.1 0.88 27 4.70 19.7 406 147
67 55.8 0.80 21 4.76 20.0 413 149 54.2 0.77 22 4.72 19.8 409 148 53.3 0.74 23 4.66 19.5 402 145
105ºF
Expanded Cooling Data — SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1 (cont.)
11
Expanded Heating Data SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1 Outdoor Ambient Temperature 65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
30.2
28.6
26.9
25.1
24.0
23.3
21.6
19.9
18.7
17.3
15.9
15.0
14.4
13.0
11.5
10.0
8.6
7.0
∆T
31.9
30.2
28.4
26.6
25.4
24.6
22.9
21.1
19.8
18.3
16.8
15.9
15.3
13.7
12.2
10.6
9.0
7.4
kW
1.79
1.75
1.72
1.68
1.7
1.65
1.62
1.58
1.68
1.64
1.60
1.58
1.56
1.52
1.48
1.45
1.41
1.37
Amps
8.4
7.8
7.3
6.9
6.7
6.6
6.2
5.9
5.7
5.4
5.2
5.1
5.0
4.7
4.4
4.2
3.9
3.5
COP
4.93
4.76
4.57
4.37
4.22
4.13
3.91
3.69
3.26
3.08
2.91
2.79
2.71
2.49
2.27
2.03
1.78
1.50
EER
16.9
16.3
15.6
14.9
14.4
14.1
13.4
12.6
11.2
10.5
9.9
9.5
9.3
8.5
7.7
6.9
6.1
5.1
SSZ160361A* / CA*F4860*6A*+TXV/ MBVC2000A*-1 Outdoor Ambient Temperature 65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
43.2
40.9
38.5
36.0
34.4
33.3
31.0
28.6
26.2
24.2
22.2
21.0
20.2
18.1
16.1
14.0
12.0
9.8
∆T
33.4
31.6
29.7
27.8
26.5
25.7
23.9
22.0
20.2
18.6
17.2
16.2
15.6
14.0
12.4
10.8
9.2
7.6
kW
2.70
2.65
2.59
2.54
2.5
2.48
2.43
2.37
2.46
2.40
2.34
2.31
2.28
2.22
2.16
2.11
2.05
1.99
Amps
13.1
12.1
11.3
10.6
10.3
10.1
9.5
9.0
8.6
8.2
7.9
7.7
7.6
7.2
6.7
6.3
5.8
5.3
COP
4.68
4.52
4.35
4.15
4.02
3.93
3.73
3.52
3.12
2.95
2.78
2.67
2.59
2.39
2.17
1.95
1.71
1.44
EER
16.0
15.5
14.9
14.2
13.7
13.4
12.7
12.0
10.6
10.1
9.5
9.1
8.9
8.2
7.4
6.7
5.8
4.9
SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1 Outdoor Ambient Temperature 65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
59.1
55.9
52.6
49.2
47.0
45.5
42.3
39.0
35.4
32.6
30.1
28.4
27.3
24.5
21.7
19.0
16.2
13.3
∆T
35.3
33.4
31.4
29.4
28.1
27.2
25.3
23.3
21.1
19.5
18.0
17.0
16.3
14.7
13.0
11.3
9.7
7.9
kW
3.69
3.62
3.54
3.47
3.4
3.40
3.32
3.25
3.14
3.06
2.99
2.95
2.92
2.85
2.78
2.71
2.63
2.56
Amps
17.6
16.3
15.2
14.3
13.8
13.5
12.7
12.1
11.5
11.0
10.5
10.2
10.1
9.6
8.9
8.4
7.7
6.9
COP
4.68
4.52
4.35
4.15
4.01
3.93
3.72
3.51
3.30
3.12
2.94
2.82
2.74
2.52
2.29
2.05
1.80
1.51
EER
16.0
15.5
14.9
14.2
13.7
13.4
12.7
12.0
11.3
10.7
10.0
9.6
9.4
8.6
7.8
7.0
6.1
5.2
SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1* Outdoor Ambient Temperature 65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
71.0
67.2
63.3
59.2
56.5
54.7
50.9
46.9
44.6
41.2
37.9
35.8
34.5
30.9
27.4
23.9
20.4
16.7
∆T
37.6
35.6
33.5
31.3
29.9
29.0
26.9
24.8
23.6
21.8
20.1
18.9
18.2
16.4
14.5
12.7
10.8
8.8
kW
4.67
4.58
4.49
4.40
4.3
4.30
4.22
4.12
4.62
4.51
4.41
4.34
4.30
4.19
4.08
3.98
3.87
3.76
Amps
22.9
21.2
19.9
18.7
18.0
17.7
16.6
15.8
15.1
14.4
13.7
13.4
13.2
12.6
11.7
11.0
10.2
9.2
COP
4.45
4.30
4.13
3.94
3.81
3.72
3.53
3.33
2.82
2.67
2.52
2.41
2.35
2.16
1.97
1.76
1.54
1.30
EER
15.2
14.7
14.1
13.5
13.0
12.7
12.1
11.4
9.6
9.1
8.6
8.2
8.0
7.4
6.7
6.0
5.3
4.4
Calculations are based on nominal CFM and 70 °F indoor dry bulb. Note: Shaded area is ARI Rating Conditions at 47°F outdoor ambient temperature
12
www.goodmanmfg.com
Amps = Outdoor unit amps (comp.+fan) kW = Total system power
SS-SSZ16
AHRI Ratings
Outdoor Unit
SSZ16 0241A*
Indoor Units Coils/Air Handlers
Cooling Ratings ˄ Furnaces
Sens.
TVA Ratings ³
SEER ¹
EER ²
Total
Sens.
Heating Ratings ˄ Hi ⁴
HSPF ⁵
Low ⁶
CFM
AHRI #
ASPT24B14A*
22,800 17,600
14.5
12.0
21,000 17,500 22,400
8.2
14,800
810
5722686
ASPT30C14A*
23,000 17,800
15.0
12.5
21,200 17,700 22,600
8.5
14,000
845
5722687
ASPT36C14A*
23,000 17,800
15.0
12.5
21,200 17,700 22,000
8.5
13,600
860
5722767
ASUF29B14A*+TXV
22,800 17,600
14.5
12.0
21,000 17,500 22,400
8.2
14,800
810
5722685
AVPTC30C14A*
23,000 17,800
15.0
12.5
21,200 17,700 22,600
8.5
14,000
740
5924415
AVPTC36C14A*
23,000 17,800
15.0
12.5
21,200 17,700 22,000
8.5
13,600
800
5924416
CA*F3636*6D*+EEP+TXV
23,400 18,100
14.0
12.0
21,600 18,000 23,000
9.5
15,000
850
4392858
CA*F3636*6D*+MBVC1200**-1A*+TXV
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.25
15,000
820
4392859
CA*F3636*6D*+MBVC1600**-1A*+TXV
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.5
15,000
880
4392860
CA*F3642*6D*+TXV
G*E80603B*B*
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.0
15,000
860
5038720
CA*F3642*6D*+TXV
A*EH800603B*A*
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.0
15,000
860
6844660
CA*F3743*6D*+MBVC1600**-1A*+TXV
24,000 18,600
16.0
13.0
22,200 18,400 23,000
8.9
15,000
880
4415245
CHPF3636B6C*+EEP+TXV
23,400 18,100
14.0
12.0
21,600 18,000 23,000
9.5
15,000
850
3300408
CHPF3642C6C*+MBVC1600**-1A*+TXV
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.5
15,000
880
3610016 5038649
CHPF3642C6C*+TXV
G*E80603B*B*
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.0
15,000
860
CHPF3642C6C*+TXV
A*EH800603B*A*
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.0
15,000
860
6844593
CHPF3743C6B*+MBVC1600**-1A*+TXV
24,000 18,600
16.0
13.0
22,200 18,400 23,000
9.5
15,000
880
3610025
ASPT36C14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,000
8.2
20,400
1,100
6514948
ASPT42C14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,200
8.5
20,000
1,175
7079300
ASPT42D14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,000
8.5
20,400
1,145
5722688
ASUF39C14A*+TXV
33,000 25,200
15.0
12.5
30,600 24,800 33,000
8.2
20,400
1,100
6514949
AVPTC42D14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,000
8.5
20,400
1,225
5924417
AVPTC48C14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,200
8.5
20,000
1,150
7079301
AVPTC48D14A*
34,400 26,200
16.0
13.0
32,000 25,800 34,000
8.75
21,000
1,075
6678813
AWUF37XX16B*+TXV
SSZ16 0361A*
Total
32,000 24,400
14.0
11.5
29,600 24,000 32,000
8.5
18,000
1,150
5010025
CA*F3743*6D*+TXV
G*VC80604B*B*
34,000 26,000
15.0
12.5
31,600 25,600 34,000
9.0
21,000
1,220
5038655
CA*F3743*6D*+TXV
G*VC80805C*B*
34,600 26,400
15.5
12.5
32,200 26,000 34,000
9.0
21,000
1,250
5038665
CA*F3743*6D*+TXV
G*E80805C*B*
34,600 26,400
15.5
12.5
32,200 26,000 34,000
9.0
21,000
1,290
5038721
CA*F3743*6D*+TXV
A*VC80604B*B*
34,000 26,000
15.0
12.5
31,600 25,600 34,000
9.0
21,000
1,220
5038760
CA*F3743*6D*+TXV
A*VC80603B*B*
34,000 26,000
15.0
12.0
31,600 25,600 34,000
9.0
21,000
1,090
5038761
CA*F3743*6D*+TXV
ADVC80805C*B*
34,600 26,400
15.5
12.5
32,200 26,000 34,000
9.0
21,000
1,250
5038764
CA*F3743*6D*+TXV
A*VC80805C*B*
34,600 26,400
15.5
12.5
32,200 26,000 34,000
9.0
21,000
1,250
5038768
CA*F3743*6D*+TXV
A*EH800805C*A*
34,600 26,400
15.5
12.5
32,200 26,000 34,000
9.0
21,000
1,290
6844662
CA*F4961*6D*+EEP+TXV
34,600 26,400
14.5
12.2
32,200 26,000 34,400
9.5
21,000
1,100
4431866
CA*F4961*6D*+MBVC2000**-1A*+TXV
34,600 26,400
16.0
13.0
32,200 26,000 34,400
9.5
21,000
1,150
4432016
CAPT3743*4A*
G*VC80604B*B*
33,400 25,600
15.0
12.5
31,000 25,200 33,200
9.0
21,000
1,000
5520814
CAPT3743*4A*
A*VC80604B*B*
33,400 25,600
15.0
12.5
31,000 25,200 33,200
9.0
21,000
1,000
5520817
CAPT3743*4A*
A*VC80603B*B*
33,400 25,600
15.0
12.0
31,000 25,200 33,200
9.0
21,000
1,000
5520818
CAPT3743*4A*
ADVC80805C*B*
33,400 25,600
15.5
12.5
31,000 25,200 33,000
9.0
21,000
990
5520820
CAPT3743*4A*
A*VC80805C*B*
33,400 25,600
15.5
12.5
31,000 25,200 33,200
9.0
21,000
995
5520821
CAPT3743*4A*
G*VC80805C*B*
33,400 25,600
15.5
12.5
31,000 25,200 33,200
9.0
21,000
995
5520822
CAPT3743*4A*
G*E80805C*B*
33,400 25,600
15.5
12.5
31,000 25,200 33,200
9.0
21,000
995
5520823
CAPT3743*4A*
A*EH800805C*A*
33,400 25,600
15.5
12.5
31,000 25,200 33,200
9.0
21,000
995
6844668
CAPT3743*4A*+MBVC1600**-1A*
32,400 24,800
15.0
12.5
30,000 24,400 32,000
8.5
20,000
1,000
5611443
CHPF3743D6B*+MBVC2000**-1A*+TXV
34,600 26,400
16.0
13.0
32,200 26,000 34,400
9.75
21,000
1,200
3610030
CHPF4860D6D*+EEP+TXV
34,600 26,400
14.5
12.2
32,200 26,000 34,400
9.5
21,000
1,100
3300413
CHPF4860D6D*+MBVC2000**-1A*+TXV
34,600 26,400
16.0
13.0
32,200 26,000 34,400
9.5
21,000
1,150
3610058
DV48PTCC14A*
33,000 25,200
15.0
12.5
30,600 24,800 33,200
8.5
20,000
1,150
7079303
See Notes on Page 14.
SS-SSZ16
www.goodmanmfg.com
13
AHRI Ratings
Outdoor Unit
SSZ16 0481A*
SSZ16 0601B*
Indoor Units
Cooling Ratings ˄
Coils/Air Handlers
Furnaces
Sens.
TVA Ratings ³
SEER ¹
EER ²
Total
Sens.
Heating Ratings ˄ Hi ⁴
HSPF ⁵
Low ⁶
CFM
AHRI #
ASPT48D14A*
45,000 34,600
15.0
12.5
41,500 34,200 44,000
8.5
28,800
1,600
5796522
ASPT60D14A*
45,000 34,600
15.0
12.5
41,500 34,200 44,000
8.5
28,800
1,600
5722689
ASUF59D14A*+TXV
45,000 34,600
14.5
12.0
41,500 34,200 44,000
8.5
28,800
1,600
5722768
AVPTC48D14A*
45,000 34,600
15.0
12.5
41,500 34,200 44,000
9.0
28,800
1,625
5924418
AVPTC60D14A*
45,000 34,600
15.0
12.5
41,500 34,200 44,000
9.0
28,800
1,625
5924419
CA*F4961*6D*+EEP+TXV
45,500 35,000
14.0
12.0
42,000 34,600 46,000
9.0
29,000
1,550
4431867
CA*F4961*6D*+MBVC2000**-1A*+TXV
47,000 36,200
16.0
13.0
43,500 35,600 46,000
9.5
34,000
1,550
4432025
46,000 35,400
16.0
13.0
42,500 35,000 45,500
9.0
30,000
1,570
5038671 6844614
CA*F4961*6D*+TXV
G*E81005C*B*
CA*F4961*6D*+TXV
A*EH801005C*A*
46,000 35,400
16.0
13.0
42,500 35,000 45,500
9.0
30,000
1,570
CAPT4961*4A*
G*E81005C*B*
46,000 35,400
15.5
13.0
42,500 35,000 45,500
9.0
30,000
1,675
5520859
CAPT4961*4A*
A*EH801005C*A*
46,000 35,400
15.5
13.0
42,500 35,000 45,500
9.0
30,000
1,675
6844670
CAPT4961*4A*+EEP
45,500 35,000
14.0
12.0
42,000 34,600 46,000
8.5
29,000
1,675
5520865
CAPT4961*4A*+MBVC2000**-1A*
47,000 36,200
16.0
13.0
43,500 35,600 46,000
9.0
34,000
1,615
5527447
CHPF4860D6D*+EEP+TXV
45,500 35,000
14.0
12.0
42,000 34,600 46,000
9.0
29,000
1,550
3300417
CHPF4860D6D*+MBVC2000**-1A*+TXV
47,000 36,200
16.0
13.0
43,500 35,600 46,000
9.5
34,000
1,550
3610060
AVPTC60D14A*
54,000 40,000
15.0
11.5
50,000 39,500 55,000
8.5
30,000
1,630
8145827
CA*F4961*6D*+MBVC2000**-1A*+TXV
57,000 42,000
16.0
12.5
53,000 41,500 56,500
9.1
35,800
1,750
4514558
CA*F4961*6D*+TXV
G*VC81005C*B*
55,500 41,000
15.5
11.8
51,500 40,500 55,000
9.0
30,000
1,800
5038650
CA*F4961*6D*+TXV
G*VC80805C*B*
55,000 40,500
15.5
11.8
51,000 40,000 55,500
9.0
30,000
1,590
5038722
CA*F4961*6D*+TXV
A*VC81005C*B*
55,500 41,000
15.5
11.8
51,500 40,500 55,000
9.0
30,000
1,800
5038759
CA*F4961*6D*+TXV
ADVC80805C*B*
54,500 40,000
15.5
11.8
50,500 40,000 55,500
9.0
30,000
1,580
5038763
CA*F4961*6D*+TXV
ADVC81005C*B*
55,500 41,000
15.5
11.8
51,500 40,500 55,000
9.0
30,000
1,820
5038765
CA*F4961*6D*+TXV
A*VC80805C*B*
55,000 40,500
15.5
11.8
51,000 40,000 55,500
9.0
30,000
1,590
5038807
56,000 41,500
16.0
12.7
52,000 41,000 55,500
9.2
35,200
1,600
4236500
CHPF4860D6D*+MBVC2000**-1A*+TXV
˄ ¹ ³ ⁵ ⁷
Total
CHPF4860D6D*+TXV
G*VC81005C*B*
55,500 41,000
15.5
11.8
51,500 40,500 55,000
9.0
30,000
1,800
5038659
CHPF4860D6D*+TXV
G*VC80805C*B*
55,000 40,500
15.5
11.8
51,000 40,000 55,500
9.0
30,000
1,590
5038662
CHPF4860D6D*+TXV
A*VC81005C*B*
55,500 41,000
15.5
11.8
51,500 40,500 55,000
9.0
30,000
1,800
5038762
CHPF4860D6D*+TXV
A*VC80805C*B*
55,000 40,500
15.5
11.8
51,000 40,000 55,500
9.0
30,000
1,590
5038766
Rated in accordance with ANSI/AHRI Standard 210/240 Seasonal Energy Efficiency Ratio TVA Rating: BTU/h @ 75°F/ 63°F - 95°F HSPF = Heating Seasonal Performance Factor CFM at High stage
² ⁴ ⁶ ⁸
Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F Rated heating capacity at 47°F outdoor per AHRI 210/240 Heating capacity at 17°F outdoor CFM at Intermediate and low stage
Notes • Always check the S&R plate for electrical data on the unit being installed. • When matching outdoor unit to indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman brand gas furnace contains the EEP cooling time delay.
14
www.goodmanmfg.com
SS-SSZ16
SS-SSZ16
BK
T2
L2
T1
L1
www.goodmanmfg.com
CM
IO
AUX
MAIN
DFT
Y
YL
PS2
BL
Y
1
BR
PU
RVC
LPS
BL/PK
YL/PK YL/PK
PU
C
C
C
R
R
C
BK
C
C
RD
RD
RD
AUX
GR
SEE NOTE 3
L1 C
USE N.E.C. CLASS 2 WIRE
NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TE RMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTOR ONLY. 4) CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION 5) 40VA MINIMUM TRANSFORMER IS REQUIRED. 6) COMMON SIDE OF TRANSFORMER MUST BE GROUNDED.
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE COMPONENT CODE C --------------- CONTACTOR CADM -------- COMFORT ALERT DIAGNOSTIC MODULE R-DFT CCR ----------- COMPRESSOR CONTACTOR RELAY CH ------------- CRANKCASE HEATER CHS ----------- CRANKCASE HEATER SWITCH CM ------------ OUTDOOR FAN MOTOR CMR ---------- CONDENSER MOTOR RELAY R COMP -------- COMPRESSOR CS ------------- COMPRESSOR SOLENOID DC ------------- DEFROST CONTROL DFT ----------- DEFROST THERMOSTAT DT ------------- DISCHARGE THERMOSTAT HPS ----------- HIGH PRESSURE SWITCH HVDR -------- HIGH VOLTAGE DEFROST RELAY IO -------------- INTERNAL OVERLOAD LPS ---------- LOW PRESSURE SWITCH R LVDR --------- LOW VOLTAGE DEFROST RELAY LVJB --------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN RVC ----------- REVERSING VALVE COIL SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE
COLOR CODE BK --------------- BLACK BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN GR---------------- GREEN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK----------- YELLOW/PINK STRIPE
Y C
BL/PK BL
NOTE 1
X AU
S
CCR
LPS
F
1
Y
⚡
C
C
SA (IF USED) NOTE 2
RCCF
SC
HPS
CNT
}
C
C
L2
FIELD LOW VOLTAGE CONNECTIONS
C-RV
H
T2
0140R00171 - B
C
O-RV RVC
PS2 Y
DC
SEE NOTE 5 & 6
O
M AI N
X AU
CH
CM
IO
2
SEE NOTE 4
R-PS1
DFT
O
SR
COMP M AI N R
CHS
IO
5
INDOOR POWER SUPPLY
W2
W
LVDR
DFT
DF2
C DF1 HVDR
T1
OUTDOOR POWER SUPPLY SEE RATING PLATE
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
S
BK
YL
EQUIPMENT GROUND
RCCF
YL
YL
BL
HERM YL F
SC
SA (IF USED) NOTE 2 RD
MAIN
Warning
IO
COMP
PU
RD
RD
RD
RD
CHS
RD
L2
T2
CH SEE NOTE 4
RD
BR
BK
L1
T1
BK BK BK
BL BL
⚠
R
BK
YL
RD
BL/PK
PU
HPS
BL
RD
Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.
BK
BK
BK
0
2
W
SR
HVDR
YL/PK
C-RV
BK OR
0
RD
0-RV
WH BK
LVDR
BL/PK
CNT
5
YL/PK
R-PS1
R-DFT
DFT
DF2
DC CCR
ALTERNATE DOUBLE POLE CONTACTOR
BK
RD
BK
DF1
O W2 R
OR WH RD
LVJB
ALTERNATE DOUBLE POLE CONTACTOR ONLY
CONTROL BOX
Wiring Diagram
15
Product Specifications
Dimensions
W
D
Model
H
Dimensions W”
D”
H”
SSZ160241A*
29
29
38¼
SSZ160361A*
35½
35½
38¼
SSZ160481A*
35½
35½
38¼
SSZ160601B*
35½
35½
38¼
Accessories Model
Description
SSZ16 024
SSZ16 036
SSZ16 048
SSZ16 060 X
ABK-20
Anchor Bracket Kit*
X
X
X
CSR-U-1
Hard-start Kit
X
X
X
CSR-U-3
Hard-start Kit
FSK01A¹
Freeze Protection Kit
X
X
X
X
LAKT01A
Low-Ambient Kit
X
X
X
X
X
X
X
X
X
X
OT18-60A²
Outdoor Thermostat w/ Lockout Stat
X
TX2N4A³
TXV Kit
X
TX3N4³
TXV Kit
TX5N4³
TXV Kit
* ¹ ² ³
X
Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0° F with 50% or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device. The TXV should always be sized based on the tonnage of the outdoor unit.
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2015 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
16
www.goodmanmfg.com
SS-SSZ16