SSZ16 High-Efficiency Split System Heat Pump Up to 16 SEER Cooling Capacity: 24,000 to 57,000 BTU/h Heating Capacity: 24,000 to 57,000 BTU/h Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 4 Expanded Heating Data........................ 12 AHRI Ratings......................................... 13 Dimensions........................................... 17 Wiring Diagram..................................... 18 Accessories........................................... 19 Standard Features • • • • • • • • • • • • • • • High-efficiency scroll compressor High-density foam compressor sound blanket SmartShift® technology to ensure quiet, reliable defrost Factory-installed bi-flow liquid-line filter drier Factory-installed suction-line accumulator Compressor short-cycle protection 850 RPM condenser fan motor Factory-installed compressor crankcase heater Factory-installed high-capacity muffler High- and low-pressure switches Service valves with sweat connections with easy access to gauge ports Copper tube / enhanced aluminum fin coil Contactor with lug connection Ground lug connection AHRI Certified; ETL Listed Cabinet Features • • • • Goodman® brand sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Top and side compressor and tubing access • Service ports and controls are accessible while unit is operating • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home) and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-SSZ16 www.goodmanmfg.com 6/15 Supersedes 9/14 Nomenclature   S S Z 16 036 1 A A 1 2 3 4,5 6,7,8 9 10 11 Brand S Goodman® (High  Feature Set  Model) Engineering  * Minor  Revision Engineering  * Major  Revision Product  Category S Split  System   Unit  Type X Condenser  R-­‐410A Z Heat  Pump  R-­‐410A 1 2 3 4 Efficiency 13 13  SEER 14 14  SEER 16 16  SEER 018 024 030 036/38 Electrical 208/230  V,  1  Phase,  60  Hz 220/240  V,  1  Phase,  50  Hz 208/230  V,  3  Phase,  60  Hz 460  V,  3  Phase,  60  Hz 1½  Tons 2  Tons 2½  Tons 3  Tons Nominal  Capacity 042        3½  Tons 048        4  Tons 060        5  Tons *  Neither  used  for  order  entry  or  inventory  management. 2 www.goodmanmfg.com SS-SSZ16 Product Specifications SSZ16 0241A SSZ16 0361A SSZ16 0481A SSZ16 0601B 24,000 24,000 70 36,000 36,000 71 48,000 48,000 72 60,000 60,000 72 Compressor RLA LRA 13.5 58.3 14.1 77.0 19.9 109.0 28.8 152.9 Condenser Fan Motor Horsepower FLA 1/6 1.1 1/6 1.0 1/6 1.0 1/6 1.0 ⅜" ¾" ⅜" ⅞" ⅜" 1⅛" ⅜" 1⅛" ⅜" ¾" Sweat 153 ⅜" ⅞" Sweat 186 ⅜" ⅞" Sweat 278 ⅜" ⅞" Sweat 273 208/230-60 17.9 208/230-60 18.6 208/230-60 25.9 208/230-60 37 30 197/253 ½" or ¾" 30 197/253 ½" or ¾" 40 197/253 ½" or ¾" 60 197/253 ½" or ¾" Equipment Weight (lbs) 190 233 305 309 Ship Weight (lbs) 208 255 327 331 Capacities and Ratings Nominal Cooling (BTU/h) Nominal Heating (BTU/h) Decibels Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge Electrical Data Volts-Hz Minimum Circuit Ampacity ² Max. Overcurrent Protection ³ Min / Max Volts Electrical Conduit Size ¹ Tested and rated in accordance with AHRI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the rating plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-SSZ16 www.goodmanmfg.com 3 4 www.goodmanmfg.com 23.9 0.89 20 1.45 5.6 215 113 23.2 0.85 21 1.44 5.6 213 112 21.4 0.82 21 1.40 5.4 207 108 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 766 875 984 59 23.5 0.78 17 1.44 5.6 213 112 22.8 0.75 18 1.43 5.5 211 110 21.1 0.72 18 1.39 5.4 205 107 Airflow MBh S/T ∆T kW 984 Amps Hi PR Lo PR MBh S/T ∆T kW 875 Amps Hi PR Lo PR MBh S/T ∆T 766 kW Amps Hi PR Lo PR 24.6 0.80 18 1.48 5.8 232 120 23.9 0.76 19 1.47 5.7 230 119 22.1 0.73 19 1.43 5.6 223 115 63 24.4 0.65 15 1.47 5.7 230 119 23.7 0.62 15 1.46 5.7 227 117 21.8 0.60 16 1.42 5.5 220 114 26.7 0.60 15 1.53 5.9 245 131 25.9 0.57 16 1.51 5.9 242 130 23.9 0.55 16 1.48 5.7 235 126 67 26.7 0.45 11 1.51 5.9 242 130 25.9 0.43 12 1.50 5.8 240 128 23.9 0.42 12 1.47 5.7 233 124 28.6 0.39 10 1.58 6.2 255 139 27.8 0.37 11 1.56 6.1 253 138 25.6 0.36 11 1.53 5.9 245 134 71 23.4 0.92 20 1.56 6.1 242 119 22.7 0.88 21 1.55 6.0 239 118 20.9 0.85 21 1.51 5.9 232 114 59 23.0 0.81 17 1.55 6.0 239 118 22.3 0.77 18 1.54 6.0 237 117 20.6 0.75 18 1.50 5.8 230 113 24.1 0.82 19 1.59 6.2 260 127 23.4 0.79 19 1.58 6.2 258 125 21.6 0.76 20 1.54 6.0 250 122 63 23.8 0.68 15 1.58 6.2 258 125 23.1 0.65 16 1.57 6.1 255 124 21.3 0.62 16 1.53 5.9 247 120 26.0 0.62 15 1.64 6.4 275 138 25.3 0.59 16 1.63 6.3 272 137 23.3 0.57 16 1.59 6.2 264 133 67 26.1 0.47 11 1.63 6.3 272 137 25.3 0.45 12 1.62 6.3 269 136 23.4 0.43 12 1.58 6.1 261 131 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 27.9 0.40 10 1.70 6.6 287 147 27.1 0.38 11 1.68 6.6 284 146 25.0 0.37 11 1.64 6.4 275 141 71 22.8 0.94 20 1.66 6.6 275 124 22.1 0.90 21 1.64 6.5 272 122 20.4 0.87 21 1.60 6.3 264 119 59 22.4 0.83 17 1.64 6.5 272 122 21.8 0.79 18 1.63 6.5 270 121 20.1 0.76 18 1.59 6.3 261 118 23.5 0.85 19 1.69 6.7 296 132 22.8 0.81 19 1.68 6.7 293 130 21.0 0.78 20 1.64 6.5 284 126 25.4 0.64 15 1.75 6.9 312 144 24.7 0.61 16 1.73 6.9 309 142 22.8 0.59 16 1.69 6.7 300 138 22.2 0.98 20 1.74 7.0 313 130 21.6 0.93 21 1.73 6.9 310 129 19.9 0.90 21 1.69 6.8 301 125 22.9 0.87 19 1.78 7.2 337 138 22.2 0.83 19 1.77 7.1 334 137 20.5 0.80 20 1.72 6.9 324 133 24.8 0.66 15 1.84 7.4 356 151 24.1 0.63 16 1.83 7.3 352 149 22.2 0.61 16 1.78 7.1 342 145 26.6 0.42 11 1.90 7.7 371 161 25.8 0.41 11 1.89 7.6 368 159 23.8 0.39 11 1.84 7.4 357 154 71 - Shaded area reflects ACCA (TVA) conditions 27.3 0.41 10 1.81 7.2 326 153 26.5 0.39 11 1.79 7.1 323 152 24.4 0.38 11 1.75 6.9 313 147 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.2 25.5 21.9 22.7 24.8 0.69 0.48 0.86 0.72 0.50 15 11 18 15 12 1.68 1.73 1.73 1.77 1.82 6.7 6.9 6.9 7.1 7.3 293 309 310 334 352 130 142 129 137 149 22.6 24.7 21.2 22.0 24.1 0.66 0.46 0.82 0.68 0.47 16 12 18 16 12 1.67 1.72 1.72 1.75 1.81 6.6 6.8 6.9 7.0 7.3 290 306 307 330 349 129 141 127 136 148 20.8 22.8 19.6 20.3 22.3 0.64 0.44 0.79 0.66 0.46 16 12 19 16 12 1.63 1.68 1.67 1.71 1.76 6.4 6.6 6.7 6.9 7.1 281 297 298 320 338 125 137 124 131 143 21.1 1.00 20 1.82 7.4 352 136 20.5 0.97 21 1.80 7.4 349 135 18.9 0.93 21 1.76 7.2 338 131 59 20.8 0.89 17 1.80 7.4 349 135 20.2 0.85 18 1.79 7.3 345 133 18.6 0.82 18 1.74 7.1 335 129 21.8 0.91 18 1.86 7.6 379 145 21.1 0.86 19 1.84 7.5 375 143 19.5 0.83 19 1.80 7.3 364 139 63 21.5 0.74 15 1.84 7.5 375 143 20.9 0.71 16 1.83 7.5 372 142 19.3 0.68 16 1.78 7.3 360 138 25.3 0.44 10 1.98 8.1 418 168 24.5 0.42 11 1.97 8.1 413 167 22.7 0.41 11 1.92 7.9 401 162 71 19.6 1.00 18 1.88 7.9 389 141 19.0 0.97 19 1.86 7.8 385 139 17.5 0.94 20 1.82 7.6 374 135 59 19.3 0.90 16 1.86 7.8 385 139 18.7 0.86 17 1.85 7.7 382 138 17.3 0.83 17 1.80 7.5 370 134 20.2 0.91 17 1.92 8.0 419 150 19.6 0.87 18 1.91 8.0 415 148 18.1 0.84 18 1.86 7.8 402 144 63 20.0 0.75 14 1.91 8.0 415 148 19.4 0.72 15 1.89 7.9 411 147 17.9 0.69 15 1.84 7.7 398 142 21.8 0.69 14 1.99 8.3 442 164 21.2 0.66 15 1.97 8.2 438 162 19.6 0.64 15 1.92 8.0 425 157 67 21.9 0.52 11 1.97 8.2 438 162 21.2 0.50 11 1.95 8.2 434 160 19.6 0.48 11 1.90 7.9 421 156 115ºF 23.4 0.44 10 2.05 8.6 461 174 22.7 0.42 10 2.04 8.5 457 173 21.0 0.41 10 1.98 8.3 443 167 71 - kW = Total system power Amps = outdoor unit amps (compressor + fan) 23.6 0.69 15 1.92 7.9 400 158 22.9 0.65 16 1.90 7.8 396 157 21.1 0.63 16 1.85 7.6 385 152 67 23.6 0.52 11 1.90 7.8 396 157 22.9 0.49 12 1.89 7.7 392 155 21.1 0.47 12 1.84 7.5 381 150 105ºF Expanded Cooling Data — SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1 SS-SSZ16 SS-SSZ16 www.goodmanmfg.com 24.8 1.00 23 1.47 5.7 220 115 24.0 0.98 25 1.46 5.7 218 114 22.2 0.94 25 1.43 5.5 211 110 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 766 875 984 59 24.3 1.00 23 1.46 5.7 218 114 23.6 0.93 23 1.45 5.6 216 113 21.8 0.90 23 1.42 5.5 209 109 Airflow MBh S/T ∆T kW 984 Amps Hi PR Lo PR MBh S/T ∆T kW 875 Amps Hi PR Lo PR MBh S/T ∆T 766 kW Amps Hi PR Lo PR 25.2 0.99 23 1.50 5.9 237 122 24.5 0.94 24 1.49 5.8 234 121 22.6 0.91 25 1.46 5.7 227 117 63 24.9 0.91 21 1.49 5.8 234 121 24.1 0.87 22 1.48 5.8 232 120 22.3 0.84 23 1.45 5.6 225 116 26.4 0.89 22 1.55 6.0 250 134 25.7 0.85 23 1.54 6.0 247 132 23.7 0.82 23 1.50 5.8 240 128 67 26.6 0.74 18 1.54 6.0 247 132 25.8 0.71 19 1.53 5.9 245 131 23.8 0.68 20 1.49 5.8 238 127 28.2 0.72 19 1.60 6.3 261 142 27.4 0.69 20 1.59 6.2 258 141 25.3 0.66 20 1.55 6.0 250 137 71 28.4 0.56 15 1.59 6.2 258 141 27.6 0.53 15 1.58 6.2 255 139 25.5 0.51 16 1.54 6.0 248 135 24.2 1.00 23 1.59 6.2 247 121 23.5 1.00 25 1.57 6.1 244 120 21.7 0.97 25 1.54 6.0 237 117 59 23.8 1.00 22 1.57 6.1 244 120 23.1 0.96 23 1.56 6.1 242 119 21.3 0.93 24 1.52 5.9 235 115 24.7 1.00 23 1.62 6.3 265 129 23.9 0.97 25 1.61 6.3 263 128 22.1 0.94 25 1.57 6.1 255 124 63 24.3 0.95 22 1.61 6.3 263 128 23.6 0.90 22 1.59 6.2 260 127 21.8 0.87 23 1.56 6.0 252 123 25.8 0.92 22 1.67 6.5 280 141 25.1 0.88 23 1.66 6.5 278 140 23.1 0.85 24 1.62 6.3 269 135 67 26.0 0.77 19 1.66 6.5 278 140 25.2 0.74 19 1.64 6.4 275 138 23.3 0.71 20 1.60 6.2 267 134 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 27.6 0.75 19 1.73 6.7 292 150 26.8 0.71 20 1.71 6.7 289 149 24.7 0.69 20 1.67 6.5 281 144 71 27.7 0.58 15 1.71 6.7 289 149 26.9 0.55 16 1.70 6.6 287 147 24.9 0.53 16 1.66 6.5 278 143 23.6 1.00 22 1.69 6.7 281 126 22.9 1.00 24 1.67 6.6 278 125 21.2 1.00 25 1.63 6.5 269 121 59 23.2 1.00 22 1.67 6.6 278 125 22.5 0.99 23 1.66 6.6 275 124 20.8 0.95 24 1.62 6.4 267 120 24.1 1.00 22 1.72 6.8 302 134 23.4 1.00 25 1.71 6.8 299 133 21.6 0.96 25 1.67 6.6 290 129 25.2 0.95 22 1.78 7.1 319 147 24.5 0.90 23 1.76 7.0 316 145 22.6 0.87 24 1.72 6.8 306 141 23.0 1.00 22 1.77 7.1 320 133 22.4 1.00 24 1.76 7.1 316 131 20.6 1.00 25 1.72 6.9 307 127 23.5 1.00 22 1.81 7.3 344 141 22.8 1.00 24 1.80 7.2 340 140 21.0 1.00 25 1.75 7.0 330 135 24.6 0.98 22 1.87 7.5 363 154 23.9 0.93 23 1.86 7.5 360 152 22.0 0.90 24 1.81 7.3 349 148 26.2 0.79 19 1.93 7.8 379 164 25.5 0.76 20 1.92 7.7 375 162 23.5 0.73 21 1.87 7.5 364 157 71 26.4 0.61 15 1.92 7.7 375 162 25.7 0.58 16 1.90 7.7 371 161 23.7 0.56 16 1.85 7.5 360 156 Shaded area reflects AHRI (TVA) conditions 26.9 0.77 19 1.84 7.3 333 156 26.1 0.73 20 1.82 7.2 329 155 24.1 0.71 20 1.78 7.1 319 150 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.7 25.3 27.1 22.6 23.1 24.7 1.00 0.79 0.59 1.00 1.00 0.82 22 19 15 21 22 19 1.71 1.76 1.82 1.76 1.80 1.86 6.8 7.0 7.2 7.1 7.2 7.5 299 316 329 316 340 360 133 145 155 131 140 152 23.0 24.6 26.3 22.0 22.5 24.0 0.93 0.75 0.56 1.00 0.96 0.78 22 20 16 23 23 20 1.69 1.75 1.81 1.74 1.78 1.84 6.7 6.9 7.2 7.0 7.2 7.4 296 313 326 313 337 356 132 144 153 130 138 151 21.3 22.7 24.3 20.3 20.7 22.2 0.89 0.73 0.54 0.98 0.92 0.75 23 20 16 24 23 20 1.65 1.71 1.76 1.70 1.74 1.79 6.5 6.8 7.0 6.8 7.0 7.2 287 303 316 304 327 345 128 139 148 126 134 146 21.9 1.00 20 1.85 7.6 359 139 21.2 1.00 22 1.83 7.5 356 138 19.6 1.00 24 1.79 7.3 345 133 59 21.5 1.00 20 1.83 7.5 356 138 20.9 1.00 22 1.82 7.4 352 136 19.3 1.02 24 1.77 7.2 342 132 22.3 1.00 21 1.89 7.7 387 148 21.7 1.00 23 1.87 7.7 383 146 20.0 1.00 24 1.83 7.5 372 142 63 22.0 1.00 21 1.87 7.7 383 146 21.3 0.99 22 1.86 7.6 379 145 19.7 0.96 23 1.81 7.4 368 141 24.9 0.82 19 2.02 8.3 426 172 24.2 0.78 20 2.00 8.2 422 170 22.3 0.76 20 1.95 8.0 409 165 71 25.1 0.63 15 2.00 8.2 422 170 24.4 0.60 15 1.98 8.1 418 168 22.5 0.58 16 1.93 7.9 405 163 20.3 1.00 19 1.91 8.0 397 144 19.7 1.00 21 1.90 7.9 393 142 18.2 1.00 22 1.85 7.7 381 138 59 19.9 1.00 19 1.90 7.9 393 142 19.3 1.00 20 1.88 7.9 389 141 17.9 1.03 22 1.83 7.6 378 137 20.7 1.00 19 1.95 8.2 427 153 20.1 1.00 21 1.94 8.1 423 151 18.5 1.00 22 1.89 7.9 410 147 63 20.4 1.00 19 1.94 8.1 423 151 19.8 1.00 21 1.92 8.0 419 150 18.2 0.97 21 1.87 7.8 406 145 21.6 1.00 20 2.02 8.5 451 167 21.0 0.97 22 2.00 8.4 447 165 19.4 0.94 22 1.95 8.2 433 160 67 21.8 0.85 17 2.00 8.4 447 165 21.1 0.82 18 1.99 8.3 442 164 19.5 0.79 18 1.94 8.1 429 159 115ºF 23.1 0.83 18 2.09 8.8 471 178 22.4 0.79 19 2.07 8.7 466 176 20.7 0.76 19 2.02 8.5 452 171 71 23.3 0.64 14 2.07 8.7 466 176 22.6 0.61 14 2.05 8.6 461 174 20.8 0.59 15 2.00 8.4 448 169 kW = Total system power Amps = outdoor unit amps (compressor + fan) 23.4 1.00 22 1.95 8.0 408 161 22.7 0.97 23 1.93 7.9 404 160 20.9 0.93 23 1.89 7.7 392 155 67 23.5 0.85 19 1.93 7.9 404 160 22.8 0.81 19 1.92 7.9 400 158 21.0 0.78 20 1.87 7.6 388 153 105ºF Expanded Cooling Data — SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1 (cont.) 5 6 www.goodmanmfg.com 59 33.9 0.76 18 1.98 7.7 217 108 32.9 0.72 18 1.97 7.7 214 107 30.4 0.70 19 1.92 7.4 208 104 34.5 0.86 20 2.00 7.8 219 109 33.5 0.82 21 1.98 7.7 217 108 30.9 0.79 21 1.94 7.5 210 105 Airflow MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 35.5 0.77 19 2.04 8.0 235 116 34.5 0.74 19 2.03 7.9 233 115 31.8 0.71 20 1.98 7.7 226 112 63 35.1 0.63 15 2.03 7.9 233 115 34.1 0.60 16 2.01 7.8 231 114 31.5 0.58 16 1.96 7.6 224 111 38.4 0.58 15 2.11 8.2 249 127 37.3 0.56 16 2.09 8.2 246 126 34.4 0.54 16 2.04 7.9 239 122 67 38.5 0.44 12 2.09 8.2 246 126 37.4 0.42 12 2.07 8.1 244 124 34.5 0.40 12 2.02 7.9 236 121 41.2 0.38 11 2.18 8.5 259 135 40.0 0.36 11 2.16 8.5 257 134 37.0 0.35 11 2.11 8.2 249 130 71 33.7 0.89 21 2.16 8.4 245 115 32.7 0.85 21 2.14 8.3 243 114 30.2 0.82 22 2.09 8.1 236 111 59 33.1 0.79 18 2.14 8.3 243 114 32.2 0.75 18 2.12 8.3 241 113 29.7 0.72 19 2.07 8.0 233 110 34.7 0.80 19 2.20 8.6 264 123 33.7 0.76 20 2.19 8.5 261 122 31.1 0.74 20 2.13 8.3 254 118 63 34.3 0.66 15 2.19 8.5 261 122 33.3 0.63 16 2.17 8.5 259 120 30.8 0.60 16 2.11 8.2 251 117 37.5 0.61 15 2.28 8.9 279 134 36.4 0.58 16 2.26 8.8 276 133 33.6 0.56 16 2.20 8.6 268 129 67 37.6 0.46 12 2.26 8.8 276 133 36.5 0.43 12 2.24 8.7 273 131 33.7 0.42 12 2.18 8.5 265 127 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 40.3 0.39 11 2.35 9.2 291 143 39.1 0.37 11 2.33 9.1 288 141 36.1 0.36 11 2.27 8.9 279 137 71 32.9 0.92 21 2.29 9.1 279 120 31.9 0.87 21 2.28 9.0 276 119 29.5 0.84 22 2.22 8.8 268 115 59 32.3 0.81 18 2.28 9.0 276 119 31.4 0.77 19 2.26 9.0 274 118 29.0 0.74 19 2.20 8.7 265 114 33.8 0.82 19 2.35 9.3 300 128 32.9 0.78 20 2.33 9.3 297 126 30.3 0.75 20 2.27 9.0 288 123 36.6 0.62 15 2.42 9.6 317 139 35.6 0.59 16 2.40 9.6 314 138 32.8 0.57 16 2.34 9.3 305 134 32.1 0.95 21 2.42 9.7 318 126 31.1 0.90 22 2.40 9.6 315 125 28.7 0.87 22 2.34 9.4 305 121 33.0 0.85 19 2.47 10.0 342 134 32.1 0.81 20 2.45 9.9 339 133 29.6 0.78 20 2.39 9.6 329 129 35.7 0.64 16 2.55 10.3 361 146 34.7 0.61 16 2.53 10.2 358 145 32.0 0.59 17 2.47 9.9 347 141 38.4 0.41 11 2.64 10.7 377 156 37.2 0.39 11 2.62 10.6 373 154 34.4 0.38 11 2.55 10.3 362 150 71 - Shaded area reflects ACCA (TVA) conditions 39.3 0.40 11 2.51 10.0 331 148 38.2 0.38 11 2.48 9.9 328 147 35.2 0.37 11 2.42 9.6 318 143 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 33.5 36.7 31.5 32.7 35.8 0.67 0.47 0.83 0.70 0.48 15 12 18 15 12 2.33 2.40 2.40 2.45 2.53 9.3 9.6 9.6 9.9 10.2 297 314 315 339 358 126 138 125 133 145 32.5 35.6 30.6 31.7 34.8 0.64 0.45 0.79 0.66 0.46 16 12 19 16 12 2.31 2.38 2.38 2.43 2.51 9.2 9.5 9.6 9.8 10.1 294 311 312 335 354 125 137 124 131 143 30.0 32.9 28.3 29.3 32.1 0.62 0.43 0.77 0.64 0.44 16 12 19 16 12 2.25 2.32 2.32 2.37 2.45 8.9 9.2 9.3 9.5 9.8 286 302 302 325 343 121 132 120 127 139 30.5 0.98 20 2.52 10.4 358 132 29.6 0.94 21 2.50 10.3 354 131 27.3 0.90 22 2.44 10.0 343 127 59 30.0 0.86 18 2.50 10.3 354 131 29.1 0.82 18 2.48 10.2 351 129 26.9 0.79 19 2.42 9.9 340 126 31.4 0.88 19 2.58 10.6 385 141 30.5 0.84 20 2.56 10.5 381 139 28.1 0.81 20 2.49 10.2 370 135 63 31.1 0.72 15 2.56 10.5 381 139 30.2 0.69 16 2.53 10.4 377 138 27.8 0.66 16 2.47 10.1 366 134 36.4 0.43 11 2.76 11.4 424 163 35.4 0.41 11 2.73 11.3 420 162 32.7 0.39 11 2.66 11.0 407 157 71 28.2 0.99 19 2.61 11.0 395 137 27.4 0.94 20 2.59 10.9 391 135 25.3 0.91 20 2.52 10.6 380 131 59 27.8 0.87 16 2.59 10.9 391 135 26.9 0.83 17 2.57 10.8 387 134 24.9 0.80 17 2.50 10.5 376 130 29.1 0.89 18 2.67 11.2 425 145 28.2 0.85 18 2.65 11.1 421 144 26.0 0.81 19 2.58 10.8 408 140 63 28.8 0.73 14 2.65 11.1 421 144 27.9 0.69 15 2.62 11.0 417 142 25.8 0.67 15 2.56 10.7 404 138 31.5 0.67 14 2.76 11.6 449 159 30.5 0.64 15 2.74 11.5 445 157 28.2 0.62 15 2.67 11.2 431 152 67 31.5 0.50 11 2.74 11.5 445 157 30.6 0.48 11 2.71 11.4 440 156 28.2 0.46 11 2.64 11.1 427 151 115ºF 33.8 0.43 10 2.86 12.0 468 169 32.8 0.41 10 2.83 11.9 464 167 30.3 0.40 11 2.76 11.6 450 162 71 - kW = Total system power Amps = outdoor unit amps (compressor + fan) 34.0 0.67 15 2.66 11.0 406 153 33.0 0.63 16 2.64 10.9 402 152 30.4 0.61 16 2.57 10.6 390 147 67 34.0 0.50 12 2.64 10.9 402 152 33.0 0.48 12 2.62 10.8 398 150 30.5 0.46 12 2.55 10.5 386 146 105ºF Expanded Cooling Data — SSZ160361A* / CA*F4860*6A* + TXV / MBVC2000A*-1 SS-SSZ16 SS-SSZ16 www.goodmanmfg.com 59 35.1 0.95 23 2.02 7.9 221 110 34.1 0.90 24 2.00 7.8 219 109 31.4 0.87 24 1.95 7.6 212 106 63 35.9 0.89 22 2.06 8.0 238 117 34.8 0.85 23 2.04 8.0 235 116 32.1 0.82 23 1.99 7.8 228 113 67 38.3 0.72 19 2.13 8.3 251 128 37.2 0.69 20 2.11 8.2 249 127 34.3 0.66 20 2.06 8.0 241 123 71 41.0 0.54 15 2.20 8.6 262 137 39.8 0.51 16 2.18 8.5 259 135 36.7 0.50 16 2.12 8.3 251 131 59 34.3 1.00 23 2.17 8.5 248 117 33.3 0.94 24 2.16 8.4 245 115 30.7 0.90 24 2.10 8.2 238 112 63 35.0 0.92 22 2.22 8.7 267 124 34.0 0.88 23 2.20 8.6 264 123 31.4 0.85 23 2.15 8.4 256 119 67 37.4 0.75 19 2.29 9.0 282 135 36.3 0.71 20 2.28 8.9 279 134 33.5 0.69 20 2.22 8.6 271 130 71 40.0 0.56 15 2.37 9.3 294 144 38.8 0.53 16 2.35 9.2 291 143 35.8 0.51 16 2.29 9.0 282 139 59 33.5 1.00 23 2.31 9.2 282 121 32.5 0.96 24 2.30 9.1 279 120 30.0 0.92 24 2.24 8.9 271 116 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.0 32.6 33.4 35.6 0.94 0.77 0.57 1.00 1.00 0.79 22 19 15 22 23 19 2.37 2.44 2.53 2.44 2.49 2.58 9.4 9.7 10.1 9.8 10.1 10.4 303 320 334 321 346 365 129 141 150 127 135 148 33.2 35.5 37.9 31.7 32.4 34.6 0.90 0.73 0.55 0.99 0.93 0.76 23 20 16 24 23 20 2.35 2.42 2.51 2.42 2.47 2.55 9.3 9.6 10.0 9.7 10.0 10.3 300 317 331 318 342 361 128 139 148 126 134 146 30.6 32.7 35.0 29.3 29.9 31.9 0.87 0.71 0.53 0.95 0.90 0.73 23 20 16 24 23 20 2.29 2.36 2.44 2.36 2.41 2.49 9.1 9.4 9.7 9.5 9.7 10.0 291 308 321 308 332 350 124 135 144 122 130 142 71 38.1 0.59 15 2.66 10.8 381 157 37.0 0.56 16 2.64 10.7 377 156 34.1 0.54 16 2.57 10.4 366 151 59 31.0 1.00 21 2.54 10.4 361 133 30.1 1.00 23 2.52 10.4 358 132 27.8 0.99 24 2.46 10.1 347 128 63 31.7 1.00 22 2.60 10.7 389 142 30.8 0.96 23 2.58 10.6 385 141 28.4 0.93 23 2.51 10.3 373 136 67 33.9 0.82 19 2.69 11.1 411 155 32.9 0.78 20 2.66 11.0 406 153 30.3 0.76 20 2.60 10.7 394 149 105ºF 71 36.2 0.61 15 2.78 11.5 428 165 35.1 0.59 16 2.76 11.4 424 163 32.4 0.57 16 2.68 11.1 411 158 59 28.7 1.00 20 2.63 11.1 399 138 27.9 1.00 21 2.61 11.0 395 137 25.7 1.00 23 2.54 10.7 383 133 63 29.4 1.00 20 2.69 11.3 430 147 28.5 0.97 21 2.67 11.2 425 145 26.3 0.94 22 2.60 10.9 413 141 67 31.4 0.83 18 2.78 11.7 454 160 30.4 0.79 18 2.76 11.6 449 159 28.1 0.76 19 2.69 11.3 436 154 115ºF 71 33.5 0.62 14 2.88 12.2 473 171 32.5 0.59 15 2.86 12.0 468 169 30.0 0.57 15 2.78 11.7 454 164 Shaded area reflects AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (compressor + fan) MBh 35.71 36.40 38.12 40.67 34.88 35.55 37.23 39.72 34.04 34.70 36.35 38.78 33.21 33.86 35.46 37.83 31.55 32.16 33.69 35.94 29.23 29.79 31.20 33.29 S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80 ∆T 24 24 22 19 24 24 23 20 23 24 23 20 23 23 23 20 21 22 23 20 20 20 21 18 2.03 2.08 2.14 2.21 2.19 2.24 2.31 2.39 2.33 2.39 2.46 2.55 2.46 2.51 2.60 2.69 2.56 2.62 2.71 2.80 2.66 2.72 2.81 2.91 1350 kW Amps 7.9 8.1 8.4 8.7 8.6 8.8 9.0 9.4 9.3 9.5 9.8 10.2 9.9 10.2 10.5 10.9 10.5 10.8 11.2 11.6 11.2 11.4 11.8 12.3 Hi PR 223 240 254 264 250 269 285 297 285 306 324 338 324 349 369 384 365 393 415 432 403 434 458 478 Lo PR 111 119 129 138 118 125 137 146 122 130 142 151 129 137 149 159 135 143 157 167 139 148 162 172 MBh 34.7 35.3 37.0 39.5 33.9 34.5 36.1 38.6 33.1 33.7 35.3 37.6 32.2 32.9 34.4 36.7 30.6 31.2 32.7 34.9 28.4 28.9 30.3 32.3 S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 ∆T 25 25 23 20 25 25 24 20 25 25 24 20 25 25 24 21 23 24 24 20 22 22 22 19 1200 kW 2.02 2.06 2.13 2.20 2.17 2.22 2.29 2.37 2.31 2.37 2.44 2.53 2.44 2.49 2.58 2.66 2.54 2.60 2.69 2.78 2.63 2.69 2.78 2.88 Amps 7.9 8.0 8.3 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.1 9.8 10.1 10.4 10.8 10.4 10.7 11.1 11.5 11.1 11.3 11.7 12.2 Hi PR 221 238 251 262 248 267 282 294 282 303 320 334 321 346 365 381 361 389 411 428 399 430 454 473 Lo PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171 MBh 32.0 32.6 34.2 36.4 31.3 31.9 33.4 35.6 30.5 31.1 32.6 34.7 29.8 30.3 31.8 33.9 28.3 28.8 30.2 32.2 26.2 26.7 28.0 29.8 S/T 0.91 0.88 0.79 0.64 0.95 0.91 0.82 0.67 0.97 0.94 0.84 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74 ∆T 26 25 24 21 26 25 24 21 26 25 24 21 26 26 24 21 25 25 24 21 23 23 22 19 1.97 2.01 2.07 2.14 2.12 2.17 2.24 2.31 2.26 2.31 2.38 2.46 2.38 2.43 2.51 2.60 2.48 2.53 2.62 2.71 2.57 2.62 2.71 2.81 1050 kW Amps 7.6 7.8 8.1 8.4 8.3 8.4 8.7 9.0 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.5 10.2 10.4 10.8 11.2 10.8 11.0 11.4 11.8 Hi PR 214 231 244 254 240 259 273 285 273 294 311 324 311 335 354 369 350 377 398 415 387 417 440 459 Lo PR 107 114 124 132 113 120 131 140 118 125 137 145 123 131 143 153 129 138 150 160 134 142 155 166 Airflow MBh S/T ∆T 1350 kW Amps Hi PR Lo PR MBh S/T ∆T 1200 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF Expanded Cooling Data — SSZ160361A* / CA*F4860*6A* + TXV / MBVC2000A*-1 (cont.) 7 8 www.goodmanmfg.com 59 46.5 0.77 19 2.68 10.2 213 110 45.2 0.74 20 2.66 10.1 211 109 41.7 0.71 20 2.60 9.8 204 106 47.3 0.88 22 2.70 10.3 215 111 46.0 0.84 23 2.68 10.2 213 110 42.4 0.81 23 2.62 9.9 206 107 Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR 48.7 0.78 20 2.76 10.5 231 118 47.3 0.75 21 2.73 10.4 229 117 43.7 0.72 21 2.67 10.1 222 113 63 48.2 0.64 16 2.73 10.4 229 117 46.8 0.61 17 2.71 10.3 227 116 43.2 0.59 17 2.65 10.0 220 112 52.8 0.59 17 2.84 10.9 244 129 51.2 0.57 17 2.82 10.8 242 128 47.3 0.55 18 2.75 10.5 235 124 67 52.9 0.45 12 2.82 10.8 242 128 51.3 0.43 13 2.80 10.7 239 126 47.4 0.41 13 2.73 10.4 232 123 56.6 0.38 11 2.93 11.3 255 137 55.0 0.36 12 2.91 11.2 252 136 50.7 0.35 12 2.84 10.9 245 132 71 46.2 0.91 22 2.90 11.1 241 117 44.9 0.87 23 2.88 11.0 239 116 41.4 0.84 23 2.81 10.7 232 113 59 45.5 0.80 19 2.88 11.0 239 116 44.1 0.76 20 2.86 10.9 236 115 40.7 0.74 20 2.79 10.6 229 112 47.6 0.81 20 2.97 11.4 260 125 46.2 0.78 21 2.94 11.3 257 124 42.7 0.75 22 2.87 11.0 249 120 63 47.1 0.67 17 2.94 11.3 257 124 45.7 0.64 17 2.92 11.2 254 122 42.2 0.61 18 2.85 10.9 247 119 51.5 0.62 17 3.06 11.7 274 136 50.0 0.59 17 3.04 11.6 271 135 46.2 0.57 18 2.96 11.3 263 131 67 51.6 0.46 13 3.04 11.6 271 135 50.1 0.44 13 3.01 11.5 269 134 46.3 0.43 13 2.94 11.2 261 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 55.3 0.40 12 3.16 12.2 286 145 53.7 0.38 12 3.13 12.1 283 144 49.6 0.36 12 3.06 11.7 275 139 71 45.1 0.93 22 3.09 12.1 274 122 43.8 0.89 23 3.06 11.9 272 121 40.4 0.86 24 2.99 11.6 263 117 59 44.4 0.82 19 3.06 11.9 272 121 43.1 0.78 20 3.04 11.8 269 119 39.8 0.75 20 2.96 11.5 261 116 46.5 0.83 20 3.15 12.4 295 130 45.1 0.80 21 3.13 12.2 292 128 41.6 0.77 22 3.05 11.9 284 125 50.3 0.63 17 3.25 12.8 312 142 48.8 0.60 17 3.23 12.6 309 140 45.1 0.58 18 3.15 12.3 299 136 44.0 0.96 22 3.25 12.9 312 128 42.8 0.92 23 3.22 12.8 309 127 39.5 0.89 24 3.14 12.4 300 123 45.3 0.86 21 3.32 13.2 336 136 44.0 0.82 21 3.29 13.1 333 135 40.6 0.79 22 3.21 12.7 323 131 49.1 0.65 17 3.42 13.6 355 149 47.6 0.62 18 3.40 13.5 352 147 44.0 0.60 18 3.31 13.1 341 143 52.7 0.42 12 3.54 14.2 370 158 51.1 0.40 12 3.51 14.0 367 157 47.2 0.39 12 3.42 13.6 356 152 71 - Shaded area reflects ACCA (TVA) conditions 54.0 0.41 12 3.36 13.2 325 151 52.4 0.39 12 3.33 13.1 322 149 48.4 0.37 12 3.25 12.8 312 145 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.0 50.4 43.3 44.9 49.2 0.69 0.47 0.85 0.71 0.49 17 13 19 17 13 3.13 3.23 3.22 3.29 3.40 12.2 12.6 12.8 13.1 13.5 292 309 309 333 351 128 140 127 135 147 44.7 48.9 42.0 43.6 47.7 0.65 0.45 0.81 0.67 0.47 17 13 20 17 13 3.10 3.20 3.19 3.26 3.37 12.1 12.5 12.7 13.0 13.4 289 306 306 330 348 127 139 126 134 146 41.2 45.2 38.8 40.2 44.1 0.63 0.44 0.78 0.65 0.45 18 13 20 18 13 3.03 3.12 3.11 3.18 3.28 11.8 12.2 12.3 12.6 13.0 281 296 297 320 338 123 135 122 130 141 41.8 1.00 22 3.38 13.7 352 134 40.6 0.95 23 3.35 13.6 348 133 37.5 0.92 23 3.27 13.2 338 129 59 41.1 0.88 19 3.35 13.6 348 133 39.9 0.84 20 3.33 13.5 345 132 36.9 0.81 20 3.24 13.1 334 128 43.1 0.89 20 3.46 14.1 378 143 41.8 0.85 21 3.43 13.9 375 141 38.6 0.82 21 3.34 13.5 363 137 63 42.6 0.73 16 3.43 13.9 374 141 41.4 0.70 17 3.40 13.8 371 140 38.2 0.67 17 3.31 13.4 360 136 50.0 0.44 11 3.69 15.1 417 166 48.6 0.41 12 3.66 14.9 412 164 44.8 0.40 12 3.57 14.5 400 159 71 38.7 1.00 20 3.50 14.5 388 139 37.6 0.96 21 3.47 14.4 385 137 34.7 0.93 22 3.38 14.0 373 133 59 38.1 0.89 18 3.47 14.4 384 137 37.0 0.85 19 3.44 14.3 381 136 34.1 0.81 19 3.35 13.9 369 132 39.9 0.90 19 3.58 14.9 418 148 38.7 0.86 20 3.55 14.8 414 146 35.8 0.83 20 3.46 14.3 401 142 63 39.5 0.74 15 3.55 14.8 414 146 38.3 0.71 16 3.52 14.6 410 145 35.4 0.68 16 3.43 14.2 397 140 43.2 0.68 16 3.69 15.4 441 161 41.9 0.65 16 3.66 15.3 437 160 38.7 0.63 16 3.57 14.8 424 155 67 43.3 0.51 12 3.66 15.3 437 160 42.0 0.49 12 3.63 15.1 433 158 38.8 0.47 12 3.54 14.7 420 153 115ºF 46.3 0.44 11 3.82 16.0 460 172 45.0 0.42 11 3.79 15.8 456 170 41.5 0.40 11 3.69 15.4 442 165 71 - kW = Total system power Amps = outdoor unit amps (compressor + fan) 46.6 0.68 17 3.57 14.5 399 156 45.3 0.64 17 3.54 14.4 395 154 41.8 0.62 18 3.45 14.0 384 150 67 46.7 0.51 13 3.54 14.4 395 154 45.4 0.48 13 3.51 14.3 391 153 41.9 0.47 13 3.42 13.9 380 148 105ºF Expanded Cooling Data — SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1 SS-SSZ16 SS-SSZ16 www.goodmanmfg.com 59 48.2 0.96 24 2.72 10.4 217 112 46.8 0.92 25 2.70 10.3 215 111 43.2 0.88 26 2.64 10.0 209 108 49.0 1.00 26 2.74 10.5 219 113 47.6 0.96 27 2.72 10.4 217 112 43.9 0.93 28 2.66 10.1 211 109 Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR 50.0 0.97 26 2.80 10.7 236 121 48.5 0.93 27 2.78 10.6 234 119 44.8 0.90 27 2.71 10.3 227 116 63 49.2 0.90 23 2.78 10.6 234 119 47.8 0.86 24 2.76 10.5 231 118 44.1 0.83 25 2.69 10.2 224 115 52.3 0.88 24 2.89 11.1 249 132 50.8 0.84 25 2.87 11.0 247 130 46.9 0.81 26 2.80 10.7 239 126 67 52.6 0.73 20 2.87 11.0 247 130 51.1 0.70 21 2.84 10.9 244 129 47.1 0.68 22 2.77 10.6 237 125 55.8 0.71 21 2.98 11.5 260 140 54.2 0.68 22 2.96 11.4 257 139 50.0 0.66 22 2.89 11.1 250 135 71 56.2 0.55 16 2.96 11.4 257 139 54.6 0.52 17 2.93 11.3 255 137 50.4 0.50 17 2.86 11.0 247 133 47.9 1.00 25 2.95 11.3 246 120 46.5 1.00 27 2.93 11.2 244 118 42.9 0.96 28 2.86 10.9 236 115 59 47.1 1.00 25 2.93 11.2 244 118 45.7 0.95 26 2.91 11.1 241 117 42.2 0.92 26 2.84 10.8 234 114 48.8 1.00 26 3.02 11.6 265 127 47.4 0.96 27 2.99 11.5 262 126 43.7 0.93 28 2.92 11.2 254 122 63 48.1 0.94 24 2.99 11.5 262 126 46.7 0.89 25 2.97 11.4 260 125 43.1 0.86 25 2.90 11.1 252 121 51.1 0.91 25 3.11 12.0 280 139 49.6 0.87 26 3.09 11.8 277 138 45.8 0.84 26 3.01 11.5 269 133 67 51.4 0.76 21 3.09 11.8 277 138 49.9 0.73 21 3.06 11.7 274 136 46.0 0.70 22 2.99 11.4 266 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 54.5 0.74 21 3.21 12.4 292 148 52.9 0.70 22 3.19 12.3 289 147 48.9 0.68 22 3.11 12.0 280 142 71 54.9 0.57 16 3.19 12.3 289 147 53.3 0.54 17 3.16 12.2 286 145 49.2 0.52 17 3.08 11.8 277 141 46.7 1.00 25 3.14 12.3 280 124 45.4 1.00 27 3.11 12.2 277 123 41.9 0.99 28 3.04 11.8 269 119 59 45.9 1.00 24 3.11 12.2 277 123 44.6 0.98 26 3.09 12.1 274 122 41.2 0.94 26 3.01 11.7 266 118 47.6 1.00 25 3.20 12.6 301 132 46.3 0.99 27 3.18 12.5 298 131 42.7 0.95 28 3.10 12.1 289 127 49.9 0.93 25 3.31 13.0 318 144 48.4 0.89 26 3.28 12.9 315 143 44.7 0.86 26 3.20 12.5 305 139 45.6 1.00 24 3.30 13.1 319 131 44.3 1.00 26 3.27 13.0 316 129 40.9 1.00 28 3.19 12.6 306 125 46.5 1.00 25 3.37 13.4 343 139 45.1 1.00 27 3.34 13.3 340 138 41.7 0.98 28 3.26 13.0 329 133 48.7 0.96 25 3.48 13.9 362 152 47.3 0.92 26 3.45 13.8 359 150 43.6 0.89 26 3.37 13.4 348 146 51.9 0.78 21 3.60 14.4 378 162 50.4 0.75 22 3.57 14.3 374 160 46.5 0.72 23 3.48 13.9 363 155 71 52.3 0.60 17 3.57 14.3 374 160 50.8 0.57 17 3.54 14.2 370 158 46.9 0.55 18 3.45 13.8 359 154 Shaded area reflects AHRI (TVA) conditions 53.2 0.76 21 3.42 13.5 332 154 51.7 0.72 22 3.39 13.4 328 152 47.7 0.70 23 3.30 13.0 319 148 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.9 50.1 53.6 44.8 45.8 48.9 0.96 0.78 0.58 1.00 1.00 0.81 24 21 16 24 24 21 3.18 3.28 3.39 3.27 3.34 3.45 12.5 12.9 13.4 13.0 13.3 13.8 298 315 328 316 340 359 131 143 152 129 138 150 45.6 48.7 52.0 43.5 44.5 47.5 0.91 0.74 0.56 1.00 0.94 0.77 25 21 17 26 25 22 3.15 3.25 3.36 3.25 3.32 3.43 12.4 12.8 13.2 12.9 13.2 13.6 295 312 325 312 336 355 130 142 151 128 136 149 42.1 44.9 48.0 40.2 41.0 43.8 0.88 0.72 0.54 0.97 0.91 0.74 25 22 17 26 25 22 3.08 3.17 3.28 3.17 3.24 3.34 12.0 12.4 12.9 12.5 12.8 13.3 286 302 315 303 326 344 126 137 146 124 132 144 43.3 1.00 23 3.44 14.0 359 137 42.1 1.00 25 3.41 13.8 355 136 38.8 1.00 26 3.32 13.5 344 131 59 42.6 1.00 22 3.41 13.8 355 136 41.3 1.00 25 3.38 13.7 352 134 38.2 1.01 26 3.30 13.3 341 130 44.2 1.00 23 3.51 14.3 386 146 42.9 1.00 25 3.49 14.2 382 144 39.6 1.00 27 3.40 13.8 371 140 63 43.5 1.00 23 3.49 14.2 382 144 42.2 0.98 25 3.46 14.1 378 143 39.0 0.94 25 3.37 13.7 367 139 49.3 0.81 21 3.75 15.4 425 169 47.9 0.77 22 3.72 15.2 421 168 44.2 0.75 22 3.63 14.8 408 163 71 49.7 0.63 16 3.72 15.2 421 168 48.2 0.60 17 3.69 15.1 417 166 44.5 0.57 17 3.60 14.7 404 161 40.1 1.00 21 3.56 14.8 396 142 39.0 1.00 23 3.53 14.7 392 140 36.0 1.00 24 3.44 14.3 381 136 59 39.4 1.00 21 3.53 14.7 392 140 38.3 1.00 23 3.50 14.5 388 139 35.3 1.02 24 3.41 14.1 377 135 40.9 1.00 22 3.64 15.2 426 151 39.7 1.00 24 3.61 15.0 422 149 36.7 1.00 25 3.52 14.6 410 145 63 40.3 1.00 21 3.61 15.0 422 149 39.1 0.99 23 3.58 14.9 418 148 36.1 0.95 23 3.49 14.5 405 143 42.8 1.00 23 3.76 15.7 450 164 41.6 0.96 24 3.73 15.5 446 163 38.4 0.93 24 3.63 15.1 432 158 67 43.1 0.84 19 3.73 15.5 446 163 41.8 0.80 20 3.69 15.4 441 161 38.6 0.78 20 3.60 15.0 428 156 115ºF 45.7 0.82 20 3.88 16.3 470 175 44.4 0.78 21 3.85 16.1 465 173 41.0 0.75 21 3.75 15.7 451 168 71 46.0 0.63 15 3.85 16.1 465 173 44.7 0.60 16 3.82 16.0 460 172 41.2 0.58 16 3.72 15.5 447 167 kW = Total system power Amps = outdoor unit amps (compressor + fan) 46.2 1.00 24 3.63 14.8 408 159 44.9 0.95 25 3.60 14.7 403 157 41.4 0.92 26 3.51 14.3 391 153 67 46.5 0.84 20 3.60 14.7 403 157 45.1 0.80 21 3.57 14.5 399 156 41.7 0.77 22 3.48 14.1 388 151 105ºF Expanded Cooling Data — SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1 (cont.) 9 10 www.goodmanmfg.com 59 55.9 0.74 19 3.55 13.9 218 104 54.2 0.71 20 3.52 13.8 216 103 53.4 0.68 21 3.48 13.6 212 101 56.8 0.84 22 3.58 14.0 220 105 55.1 0.80 23 3.55 13.9 218 104 54.3 0.78 24 3.50 13.7 214 102 Airflow MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR 58.5 0.75 20 3.65 14.4 237 112 56.8 0.72 21 3.62 14.2 235 111 55.9 0.69 22 3.58 14.0 231 109 63 57.9 0.62 16 3.62 14.2 234 111 56.2 0.59 17 3.60 14.1 232 110 55.4 0.57 18 3.55 13.9 228 108 63.3 0.57 17 3.77 14.8 250 122 61.5 0.54 18 3.74 14.7 248 121 60.5 0.52 18 3.69 14.5 243 119 67 63.4 0.43 13 3.74 14.7 248 121 61.6 0.41 13 3.71 14.6 245 120 60.7 0.39 14 3.66 14.3 241 118 67.9 0.37 11 3.89 15.4 261 130 66.0 0.35 12 3.85 15.2 258 129 65.0 0.34 13 3.80 15.0 254 127 71 55.5 0.87 22 3.85 15.1 247 111 53.9 0.83 24 3.82 15.0 245 110 53.1 0.80 24 3.77 14.8 240 108 59 54.6 0.77 19 3.82 15.0 244 110 53.0 0.73 20 3.79 14.9 242 109 52.2 0.71 21 3.74 14.6 238 107 57.1 0.78 21 3.93 15.5 266 118 55.5 0.74 22 3.90 15.4 263 117 54.6 0.72 23 3.85 15.1 259 115 63 56.5 0.64 17 3.90 15.4 263 117 54.9 0.61 18 3.87 15.2 261 116 54.1 0.59 18 3.82 15.0 256 114 61.8 0.59 17 4.05 16.0 281 129 60.0 0.56 18 4.02 15.9 278 128 59.1 0.54 18 3.97 15.6 273 126 67 62.0 0.44 13 4.02 15.9 278 128 60.1 0.42 13 3.99 15.7 275 126 59.2 0.41 14 3.94 15.5 270 124 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 66.4 0.38 12 4.19 16.6 293 137 64.4 0.36 12 4.15 16.5 290 136 63.5 0.35 13 4.09 16.2 285 134 71 54.2 0.90 22 4.09 16.4 281 115 52.6 0.85 24 4.05 16.3 278 114 51.8 0.82 25 4.00 16.0 273 112 59 53.3 0.79 19 4.05 16.3 278 114 51.7 0.75 20 4.02 16.1 275 113 50.9 0.72 21 3.97 15.9 271 111 55.8 0.80 21 4.18 16.8 302 123 54.1 0.76 22 4.14 16.7 299 122 53.3 0.74 23 4.08 16.4 294 119 60.4 0.61 17 4.31 17.4 319 134 58.6 0.58 18 4.27 17.2 316 133 57.7 0.56 18 4.22 17.0 311 130 52.8 0.92 22 4.30 17.6 320 121 51.3 0.88 24 4.26 17.4 317 120 50.5 0.85 25 4.20 17.1 311 118 54.4 0.83 21 4.39 18.0 344 129 52.8 0.79 22 4.36 17.8 341 128 52.0 0.76 23 4.30 17.6 335 126 58.9 0.63 17 4.53 18.6 364 141 57.2 0.60 18 4.50 18.4 360 139 56.3 0.58 19 4.43 18.1 354 137 63.2 0.40 12 4.68 19.3 379 150 61.4 0.38 12 4.64 19.1 375 148 60.4 0.37 13 4.58 18.8 369 146 71 - Shaded area reflects ACCA (TVA) conditions 64.8 0.39 12 4.45 18.1 333 143 62.9 0.37 12 4.41 17.9 330 141 62.0 0.36 13 4.35 17.6 324 139 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.81 0.68 0.47 17 13 19 17 13 4.14 4.27 4.26 4.36 4.50 16.7 17.2 17.4 17.8 18.4 299 316 317 341 360 122 133 120 128 139 53.6 58.7 50.4 52.3 57.3 0.63 0.43 0.78 0.65 0.45 18 13 21 18 14 4.11 4.24 4.23 4.32 4.46 16.5 17.1 17.3 17.7 18.3 296 313 314 337 356 120 131 119 126 138 52.8 57.8 49.7 51.5 56.4 0.61 0.42 0.75 0.62 0.43 18 14 21 18 14 4.05 4.18 4.17 4.26 4.40 16.3 16.8 17.0 17.4 18.0 291 308 308 332 350 118 129 117 124 136 50.2 0.96 22 4.48 18.7 360 127 48.7 0.91 23 4.44 18.5 356 126 48.0 0.88 24 4.38 18.2 350 124 59 49.4 0.84 19 4.44 18.5 356 126 47.9 0.80 20 4.40 18.4 353 125 47.2 0.78 21 4.34 18.1 347 122 51.7 0.86 20 4.58 19.2 387 135 50.2 0.82 22 4.54 19.0 383 134 49.4 0.79 22 4.47 18.7 377 132 63 51.2 0.70 17 4.54 19.0 383 134 49.7 0.67 18 4.50 18.8 380 132 48.9 0.65 18 4.44 18.5 373 130 60.0 0.42 12 4.88 20.5 427 157 58.3 0.40 12 4.84 20.4 422 156 57.4 0.38 13 4.77 20.0 415 153 71 46.5 0.97 21 4.63 19.8 398 131 45.1 0.92 22 4.59 19.6 394 130 44.5 0.89 23 4.53 19.3 387 128 59 45.7 0.85 18 4.59 19.6 394 130 44.4 0.81 19 4.55 19.4 390 129 43.7 0.78 20 4.49 19.1 383 127 47.9 0.87 19 4.73 20.3 428 140 46.5 0.83 20 4.69 20.1 424 138 45.8 0.80 21 4.63 19.8 417 136 63 47.4 0.71 15 4.69 20.1 424 138 46.0 0.68 16 4.65 19.9 419 137 45.3 0.65 17 4.59 19.6 412 135 51.8 0.65 16 4.89 21.0 452 153 50.3 0.62 17 4.85 20.8 447 151 49.6 0.60 17 4.78 20.5 440 149 67 51.9 0.49 12 4.85 20.8 447 151 50.4 0.47 12 4.81 20.6 443 150 49.7 0.45 13 4.74 20.3 435 147 115ºF 55.6 0.42 11 5.05 21.8 471 163 54.0 0.40 11 5.01 21.6 467 161 53.2 0.39 12 4.94 21.2 459 158 71 - kW = Total system power Amps = outdoor unit amps (compressor + fan) 55.9 0.65 17 4.72 19.8 409 148 54.3 0.62 18 4.69 19.6 405 146 53.5 0.60 18 4.62 19.3 398 144 67 56.1 0.49 13 4.68 19.6 405 146 54.4 0.47 13 4.65 19.4 401 145 53.6 0.45 14 4.58 19.1 394 142 105ºF Expanded Cooling Data — SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1 SS-SSZ16 SS-SSZ16 www.goodmanmfg.com 59 57.8 0.92 25 3.61 14.1 222 106 56.1 0.88 26 3.58 14.0 220 105 55.3 0.85 27 3.53 13.8 216 103 58.8 0.97 26 3.64 14.3 225 107 57.1 0.92 28 3.61 14.1 222 106 56.3 0.89 29 3.56 13.9 219 104 Airflow MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR MBh S/T ∆T 2000 kW Amps Hi PR Lo PR MBh S/T ∆T 1750 kW Amps Hi PR Lo PR MBh S/T ∆T 1600 kW Amps Hi PR Lo PR 60.0 0.93 26 3.71 14.6 242 114 58.2 0.89 27 3.68 14.5 239 113 57.3 0.86 28 3.63 14.3 235 111 63 59.1 0.87 24 3.68 14.5 239 113 57.4 0.83 25 3.65 14.4 237 112 56.5 0.80 26 3.60 14.1 233 110 62.8 0.84 24 3.83 15.1 255 125 61.0 0.80 26 3.80 15.0 253 123 60.1 0.78 27 3.75 14.7 248 121 67 63.1 0.71 20 3.80 15.0 253 123 61.3 0.67 22 3.77 14.8 250 122 60.4 0.65 23 3.72 14.6 246 120 67.0 0.68 21 3.95 15.6 266 133 65.0 0.65 22 3.92 15.5 264 131 64.1 0.63 23 3.86 15.3 259 129 71 67.5 0.53 16 3.92 15.5 264 131 65.5 0.50 17 3.89 15.4 261 130 64.5 0.48 18 3.83 15.1 256 128 57.5 1.00 26 3.91 15.4 252 113 55.8 0.96 28 3.88 15.3 249 112 54.9 0.92 29 3.83 15.0 245 110 59 56.5 0.96 25 3.88 15.3 249 112 54.8 0.91 26 3.85 15.1 247 111 54.0 0.88 27 3.80 14.9 243 109 58.6 0.97 26 3.99 15.8 271 121 56.9 0.92 28 3.96 15.6 268 119 56.0 0.89 29 3.91 15.4 264 117 63 57.7 0.90 24 3.96 15.6 268 119 56.0 0.86 25 3.93 15.5 266 118 55.2 0.83 26 3.88 15.3 261 116 61.3 0.87 25 4.12 16.3 286 132 59.6 0.83 26 4.09 16.2 284 130 58.7 0.80 27 4.03 15.9 279 128 67 61.6 0.73 21 4.09 16.2 284 130 59.9 0.70 22 4.05 16.0 281 129 59.0 0.67 23 4.00 15.8 276 127 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 65.4 0.71 21 4.25 16.9 299 140 63.5 0.68 23 4.22 16.8 296 139 62.6 0.65 23 4.16 16.5 291 136 71 65.9 0.55 17 4.22 16.8 296 139 64.0 0.52 18 4.19 16.6 293 137 63.0 0.50 18 4.13 16.4 288 135 56.1 1.00 26 4.15 16.7 287 118 54.5 0.98 28 4.12 16.6 284 117 53.6 0.95 29 4.06 16.3 279 115 59 55.1 1.00 25 4.12 16.6 284 117 53.5 0.94 26 4.09 16.4 281 115 52.7 0.90 27 4.03 16.2 276 113 57.2 0.99 26 4.24 17.2 308 125 55.5 0.95 28 4.21 17.0 305 124 54.7 0.91 29 4.15 16.7 300 122 59.9 0.90 25 4.38 17.7 326 137 58.1 0.86 26 4.34 17.6 322 135 57.3 0.82 27 4.28 17.3 317 133 54.7 1.00 25 4.37 17.9 326 124 53.1 1.00 28 4.33 17.7 323 122 52.3 0.98 29 4.27 17.5 318 120 55.8 1.00 26 4.46 18.3 351 132 54.2 0.98 28 4.43 18.2 348 130 53.3 0.94 29 4.37 17.9 342 128 58.4 0.93 25 4.61 18.9 371 144 56.7 0.88 26 4.57 18.8 367 142 55.9 0.85 27 4.51 18.5 361 140 62.3 0.75 22 4.76 19.7 387 153 60.5 0.72 23 4.72 19.5 383 151 59.6 0.69 24 4.66 19.2 377 149 71 62.8 0.58 17 4.72 19.5 383 151 60.9 0.55 18 4.68 19.3 379 150 60.0 0.53 18 4.62 19.0 373 147 Shaded area reflects AHRI (TVA) conditions 63.9 0.73 21 4.52 18.4 340 146 62.0 0.69 23 4.49 18.2 336 144 61.1 0.67 23 4.42 17.9 331 142 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.3 60.2 64.3 53.8 55.0 58.7 0.92 0.75 0.56 1.00 0.95 0.77 24 21 17 25 24 21 4.21 4.34 4.49 4.33 4.43 4.57 17.0 17.6 18.2 17.7 18.2 18.8 305 322 336 323 348 367 124 135 144 122 130 142 54.7 58.4 62.5 52.2 53.4 57.0 0.88 0.71 0.53 0.97 0.91 0.74 25 22 18 27 25 22 4.18 4.31 4.45 4.30 4.39 4.53 16.8 17.4 18.1 17.6 18.0 18.6 302 319 333 320 344 364 123 134 143 121 129 141 53.9 57.5 61.5 51.4 52.6 56.1 0.85 0.69 0.52 0.93 0.87 0.71 26 23 18 28 26 23 4.12 4.25 4.39 4.24 4.33 4.47 16.6 17.1 17.8 17.3 17.7 18.3 297 314 327 315 338 357 121 132 140 119 127 138 52.0 1.00 24 4.55 19.0 367 130 50.5 1.00 27 4.51 18.9 364 128 49.7 1.00 29 4.45 18.6 357 126 59 51.1 1.00 23 4.51 18.9 364 128 49.6 1.00 26 4.48 18.7 360 127 48.9 0.97 27 4.41 18.4 354 125 53.0 1.00 24 4.65 19.5 395 138 51.4 1.00 27 4.61 19.3 391 137 50.7 0.98 29 4.55 19.0 385 134 63 52.2 1.00 24 4.61 19.3 391 137 50.7 0.94 25 4.58 19.2 387 135 49.9 0.91 26 4.51 18.9 381 133 59.2 0.78 21 4.96 20.9 435 160 57.5 0.74 22 4.92 20.7 431 159 56.6 0.72 23 4.85 20.4 424 156 71 59.6 0.60 16 4.92 20.7 431 159 57.9 0.57 17 4.88 20.5 427 157 57.0 0.55 18 4.81 20.2 419 154 48.2 1.00 22 4.71 20.2 406 134 46.7 1.00 25 4.67 20.0 402 133 46.0 1.00 26 4.60 19.7 395 130 59 47.3 1.00 22 4.67 20.0 402 133 45.9 1.00 24 4.63 19.8 398 131 45.3 0.98 25 4.57 19.5 391 129 49.1 1.00 23 4.81 20.7 437 143 47.7 1.00 25 4.77 20.5 432 141 46.9 0.99 27 4.71 20.2 425 139 63 48.4 1.00 22 4.77 20.5 432 141 46.9 0.95 23 4.73 20.3 428 140 46.2 0.92 24 4.67 20.0 421 137 51.4 0.97 23 4.97 21.4 461 156 49.9 0.92 24 4.93 21.2 456 154 49.2 0.89 25 4.86 20.8 449 152 67 51.7 0.81 19 4.93 21.2 456 154 50.2 0.77 20 4.89 21.0 452 153 49.4 0.74 21 4.82 20.6 444 150 115ºF 54.8 0.79 20 5.14 22.2 481 166 53.2 0.75 21 5.10 22.0 476 164 52.4 0.72 22 5.02 21.6 468 161 71 55.2 0.61 15 5.10 22.0 476 164 53.6 0.58 16 5.05 21.8 471 163 52.8 0.56 17 4.98 21.4 463 160 kW = Total system power Amps = outdoor unit amps (compressor + fan) 55.5 0.96 25 4.80 20.2 417 151 53.9 0.92 26 4.76 20.0 413 149 53.1 0.88 27 4.70 19.7 406 147 67 55.8 0.80 21 4.76 20.0 413 149 54.2 0.77 22 4.72 19.8 409 148 53.3 0.74 23 4.66 19.5 402 145 105ºF Expanded Cooling Data — SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1 (cont.) 11 Expanded Heating Data SSZ160241A* / CA*F3636*6A* + TXV / MBVC1600A*-1 Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 30.2 28.6 26.9 25.1 24.0 23.3 21.6 19.9 18.7 17.3 15.9 15.0 14.4 13.0 11.5 10.0 8.6 7.0 ∆T 31.9 30.2 28.4 26.6 25.4 24.6 22.9 21.1 19.8 18.3 16.8 15.9 15.3 13.7 12.2 10.6 9.0 7.4 kW 1.79 1.75 1.72 1.68 1.7 1.65 1.62 1.58 1.68 1.64 1.60 1.58 1.56 1.52 1.48 1.45 1.41 1.37 Amps 8.4 7.8 7.3 6.9 6.7 6.6 6.2 5.9 5.7 5.4 5.2 5.1 5.0 4.7 4.4 4.2 3.9 3.5 COP 4.93 4.76 4.57 4.37 4.22 4.13 3.91 3.69 3.26 3.08 2.91 2.79 2.71 2.49 2.27 2.03 1.78 1.50 EER 16.9 16.3 15.6 14.9 14.4 14.1 13.4 12.6 11.2 10.5 9.9 9.5 9.3 8.5 7.7 6.9 6.1 5.1 SSZ160361A* / CA*F4860*6A*+TXV/ MBVC2000A*-1 Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 43.2 40.9 38.5 36.0 34.4 33.3 31.0 28.6 26.2 24.2 22.2 21.0 20.2 18.1 16.1 14.0 12.0 9.8 ∆T 33.4 31.6 29.7 27.8 26.5 25.7 23.9 22.0 20.2 18.6 17.2 16.2 15.6 14.0 12.4 10.8 9.2 7.6 kW 2.70 2.65 2.59 2.54 2.5 2.48 2.43 2.37 2.46 2.40 2.34 2.31 2.28 2.22 2.16 2.11 2.05 1.99 Amps 13.1 12.1 11.3 10.6 10.3 10.1 9.5 9.0 8.6 8.2 7.9 7.7 7.6 7.2 6.7 6.3 5.8 5.3 COP 4.68 4.52 4.35 4.15 4.02 3.93 3.73 3.52 3.12 2.95 2.78 2.67 2.59 2.39 2.17 1.95 1.71 1.44 EER 16.0 15.5 14.9 14.2 13.7 13.4 12.7 12.0 10.6 10.1 9.5 9.1 8.9 8.2 7.4 6.7 5.8 4.9 SSZ160481A* / CA*F4860*6A* + TXV / MBVC2000A*-1 Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 59.1 55.9 52.6 49.2 47.0 45.5 42.3 39.0 35.4 32.6 30.1 28.4 27.3 24.5 21.7 19.0 16.2 13.3 ∆T 35.3 33.4 31.4 29.4 28.1 27.2 25.3 23.3 21.1 19.5 18.0 17.0 16.3 14.7 13.0 11.3 9.7 7.9 kW 3.69 3.62 3.54 3.47 3.4 3.40 3.32 3.25 3.14 3.06 2.99 2.95 2.92 2.85 2.78 2.71 2.63 2.56 Amps 17.6 16.3 15.2 14.3 13.8 13.5 12.7 12.1 11.5 11.0 10.5 10.2 10.1 9.6 8.9 8.4 7.7 6.9 COP 4.68 4.52 4.35 4.15 4.01 3.93 3.72 3.51 3.30 3.12 2.94 2.82 2.74 2.52 2.29 2.05 1.80 1.51 EER 16.0 15.5 14.9 14.2 13.7 13.4 12.7 12.0 11.3 10.7 10.0 9.6 9.4 8.6 7.8 7.0 6.1 5.2 SSZ160601B* / CAPF4961*6A* / MBVC2000A*-1* Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 71.0 67.2 63.3 59.2 56.5 54.7 50.9 46.9 44.6 41.2 37.9 35.8 34.5 30.9 27.4 23.9 20.4 16.7 ∆T 37.6 35.6 33.5 31.3 29.9 29.0 26.9 24.8 23.6 21.8 20.1 18.9 18.2 16.4 14.5 12.7 10.8 8.8 kW 4.67 4.58 4.49 4.40 4.3 4.30 4.22 4.12 4.62 4.51 4.41 4.34 4.30 4.19 4.08 3.98 3.87 3.76 Amps 22.9 21.2 19.9 18.7 18.0 17.7 16.6 15.8 15.1 14.4 13.7 13.4 13.2 12.6 11.7 11.0 10.2 9.2 COP 4.45 4.30 4.13 3.94 3.81 3.72 3.53 3.33 2.82 2.67 2.52 2.41 2.35 2.16 1.97 1.76 1.54 1.30 EER 15.2 14.7 14.1 13.5 13.0 12.7 12.1 11.4 9.6 9.1 8.6 8.2 8.0 7.4 6.7 6.0 5.3 4.4 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Note: Shaded area is ARI Rating Conditions at 47°F outdoor ambient temperature 12 www.goodmanmfg.com Amps = Outdoor unit amps (comp.+fan) kW = Total system power SS-SSZ16 AHRI Ratings Outdoor Unit SSZ16 0241A* Indoor Units Coils/Air Handlers Cooling Ratings ˄ Furnaces Sens. TVA Ratings ³ SEER ¹ EER ² Total Sens. Heating Ratings ˄ Hi ⁴ HSPF ⁵ Low ⁶ CFM AHRI # ASPT24B14A* 22,800 17,600 14.5 12.0 21,000 17,500 22,400 8.2 14,800 810 5722686 ASPT30C14A* 23,000 17,800 15.0 12.5 21,200 17,700 22,600 8.5 14,000 845 5722687 ASPT36C14A* 23,000 17,800 15.0 12.5 21,200 17,700 22,000 8.5 13,600 860 5722767 ASUF29B14A*+TXV 22,800 17,600 14.5 12.0 21,000 17,500 22,400 8.2 14,800 810 5722685 AVPTC30C14A* 23,000 17,800 15.0 12.5 21,200 17,700 22,600 8.5 14,000 740 5924415 AVPTC36C14A* 23,000 17,800 15.0 12.5 21,200 17,700 22,000 8.5 13,600 800 5924416 CA*F3636*6D*+EEP+TXV 23,400 18,100 14.0 12.0 21,600 18,000 23,000 9.5 15,000 850 4392858 CA*F3636*6D*+MBVC1200**-1A*+TXV 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.25 15,000 820 4392859 CA*F3636*6D*+MBVC1600**-1A*+TXV 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.5 15,000 880 4392860 CA*F3642*6D*+TXV G*E80603B*B* 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.0 15,000 860 5038720 CA*F3642*6D*+TXV A*EH800603B*A* 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.0 15,000 860 6844660 CA*F3743*6D*+MBVC1600**-1A*+TXV 24,000 18,600 16.0 13.0 22,200 18,400 23,000 8.9 15,000 880 4415245 CHPF3636B6C*+EEP+TXV 23,400 18,100 14.0 12.0 21,600 18,000 23,000 9.5 15,000 850 3300408 CHPF3642C6C*+MBVC1600**-1A*+TXV 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.5 15,000 880 3610016 5038649 CHPF3642C6C*+TXV G*E80603B*B* 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.0 15,000 860 CHPF3642C6C*+TXV A*EH800603B*A* 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.0 15,000 860 6844593 CHPF3743C6B*+MBVC1600**-1A*+TXV 24,000 18,600 16.0 13.0 22,200 18,400 23,000 9.5 15,000 880 3610025 ASPT36C14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,000 8.2 20,400 1,100 6514948 ASPT42C14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,200 8.5 20,000 1,175 7079300 ASPT42D14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,000 8.5 20,400 1,145 5722688 ASUF39C14A*+TXV 33,000 25,200 15.0 12.5 30,600 24,800 33,000 8.2 20,400 1,100 6514949 AVPTC42D14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,000 8.5 20,400 1,225 5924417 AVPTC48C14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,200 8.5 20,000 1,150 7079301 AVPTC48D14A* 34,400 26,200 16.0 13.0 32,000 25,800 34,000 8.75 21,000 1,075 6678813 AWUF37XX16B*+TXV SSZ16 0361A* Total 32,000 24,400 14.0 11.5 29,600 24,000 32,000 8.5 18,000 1,150 5010025 CA*F3743*6D*+TXV G*VC80604B*B* 34,000 26,000 15.0 12.5 31,600 25,600 34,000 9.0 21,000 1,220 5038655 CA*F3743*6D*+TXV G*VC80805C*B* 34,600 26,400 15.5 12.5 32,200 26,000 34,000 9.0 21,000 1,250 5038665 CA*F3743*6D*+TXV G*E80805C*B* 34,600 26,400 15.5 12.5 32,200 26,000 34,000 9.0 21,000 1,290 5038721 CA*F3743*6D*+TXV A*VC80604B*B* 34,000 26,000 15.0 12.5 31,600 25,600 34,000 9.0 21,000 1,220 5038760 CA*F3743*6D*+TXV A*VC80603B*B* 34,000 26,000 15.0 12.0 31,600 25,600 34,000 9.0 21,000 1,090 5038761 CA*F3743*6D*+TXV ADVC80805C*B* 34,600 26,400 15.5 12.5 32,200 26,000 34,000 9.0 21,000 1,250 5038764 CA*F3743*6D*+TXV A*VC80805C*B* 34,600 26,400 15.5 12.5 32,200 26,000 34,000 9.0 21,000 1,250 5038768 CA*F3743*6D*+TXV A*EH800805C*A* 34,600 26,400 15.5 12.5 32,200 26,000 34,000 9.0 21,000 1,290 6844662 CA*F4961*6D*+EEP+TXV 34,600 26,400 14.5 12.2 32,200 26,000 34,400 9.5 21,000 1,100 4431866 CA*F4961*6D*+MBVC2000**-1A*+TXV 34,600 26,400 16.0 13.0 32,200 26,000 34,400 9.5 21,000 1,150 4432016 CAPT3743*4A* G*VC80604B*B* 33,400 25,600 15.0 12.5 31,000 25,200 33,200 9.0 21,000 1,000 5520814 CAPT3743*4A* A*VC80604B*B* 33,400 25,600 15.0 12.5 31,000 25,200 33,200 9.0 21,000 1,000 5520817 CAPT3743*4A* A*VC80603B*B* 33,400 25,600 15.0 12.0 31,000 25,200 33,200 9.0 21,000 1,000 5520818 CAPT3743*4A* ADVC80805C*B* 33,400 25,600 15.5 12.5 31,000 25,200 33,000 9.0 21,000 990 5520820 CAPT3743*4A* A*VC80805C*B* 33,400 25,600 15.5 12.5 31,000 25,200 33,200 9.0 21,000 995 5520821 CAPT3743*4A* G*VC80805C*B* 33,400 25,600 15.5 12.5 31,000 25,200 33,200 9.0 21,000 995 5520822 CAPT3743*4A* G*E80805C*B* 33,400 25,600 15.5 12.5 31,000 25,200 33,200 9.0 21,000 995 5520823 CAPT3743*4A* A*EH800805C*A* 33,400 25,600 15.5 12.5 31,000 25,200 33,200 9.0 21,000 995 6844668 CAPT3743*4A*+MBVC1600**-1A* 32,400 24,800 15.0 12.5 30,000 24,400 32,000 8.5 20,000 1,000 5611443 CHPF3743D6B*+MBVC2000**-1A*+TXV 34,600 26,400 16.0 13.0 32,200 26,000 34,400 9.75 21,000 1,200 3610030 CHPF4860D6D*+EEP+TXV 34,600 26,400 14.5 12.2 32,200 26,000 34,400 9.5 21,000 1,100 3300413 CHPF4860D6D*+MBVC2000**-1A*+TXV 34,600 26,400 16.0 13.0 32,200 26,000 34,400 9.5 21,000 1,150 3610058 DV48PTCC14A* 33,000 25,200 15.0 12.5 30,600 24,800 33,200 8.5 20,000 1,150 7079303 See Notes on Page 14. SS-SSZ16 www.goodmanmfg.com 13 AHRI Ratings Outdoor Unit SSZ16 0481A* SSZ16 0601B* Indoor Units Cooling Ratings ˄ Coils/Air Handlers Furnaces Sens. TVA Ratings ³ SEER ¹ EER ² Total Sens. Heating Ratings ˄ Hi ⁴ HSPF ⁵ Low ⁶ CFM AHRI # ASPT48D14A* 45,000 34,600 15.0 12.5 41,500 34,200 44,000 8.5 28,800 1,600 5796522 ASPT60D14A* 45,000 34,600 15.0 12.5 41,500 34,200 44,000 8.5 28,800 1,600 5722689 ASUF59D14A*+TXV 45,000 34,600 14.5 12.0 41,500 34,200 44,000 8.5 28,800 1,600 5722768 AVPTC48D14A* 45,000 34,600 15.0 12.5 41,500 34,200 44,000 9.0 28,800 1,625 5924418 AVPTC60D14A* 45,000 34,600 15.0 12.5 41,500 34,200 44,000 9.0 28,800 1,625 5924419 CA*F4961*6D*+EEP+TXV 45,500 35,000 14.0 12.0 42,000 34,600 46,000 9.0 29,000 1,550 4431867 CA*F4961*6D*+MBVC2000**-1A*+TXV 47,000 36,200 16.0 13.0 43,500 35,600 46,000 9.5 34,000 1,550 4432025 46,000 35,400 16.0 13.0 42,500 35,000 45,500 9.0 30,000 1,570 5038671 6844614 CA*F4961*6D*+TXV G*E81005C*B* CA*F4961*6D*+TXV A*EH801005C*A* 46,000 35,400 16.0 13.0 42,500 35,000 45,500 9.0 30,000 1,570 CAPT4961*4A* G*E81005C*B* 46,000 35,400 15.5 13.0 42,500 35,000 45,500 9.0 30,000 1,675 5520859 CAPT4961*4A* A*EH801005C*A* 46,000 35,400 15.5 13.0 42,500 35,000 45,500 9.0 30,000 1,675 6844670 CAPT4961*4A*+EEP 45,500 35,000 14.0 12.0 42,000 34,600 46,000 8.5 29,000 1,675 5520865 CAPT4961*4A*+MBVC2000**-1A* 47,000 36,200 16.0 13.0 43,500 35,600 46,000 9.0 34,000 1,615 5527447 CHPF4860D6D*+EEP+TXV 45,500 35,000 14.0 12.0 42,000 34,600 46,000 9.0 29,000 1,550 3300417 CHPF4860D6D*+MBVC2000**-1A*+TXV 47,000 36,200 16.0 13.0 43,500 35,600 46,000 9.5 34,000 1,550 3610060 AVPTC60D14A* 54,000 40,000 15.0 11.5 50,000 39,500 55,000 8.5 30,000 1,630 8145827 CA*F4961*6D*+MBVC2000**-1A*+TXV 57,000 42,000 16.0 12.5 53,000 41,500 56,500 9.1 35,800 1,750 4514558 CA*F4961*6D*+TXV G*VC81005C*B* 55,500 41,000 15.5 11.8 51,500 40,500 55,000 9.0 30,000 1,800 5038650 CA*F4961*6D*+TXV G*VC80805C*B* 55,000 40,500 15.5 11.8 51,000 40,000 55,500 9.0 30,000 1,590 5038722 CA*F4961*6D*+TXV A*VC81005C*B* 55,500 41,000 15.5 11.8 51,500 40,500 55,000 9.0 30,000 1,800 5038759 CA*F4961*6D*+TXV ADVC80805C*B* 54,500 40,000 15.5 11.8 50,500 40,000 55,500 9.0 30,000 1,580 5038763 CA*F4961*6D*+TXV ADVC81005C*B* 55,500 41,000 15.5 11.8 51,500 40,500 55,000 9.0 30,000 1,820 5038765 CA*F4961*6D*+TXV A*VC80805C*B* 55,000 40,500 15.5 11.8 51,000 40,000 55,500 9.0 30,000 1,590 5038807 56,000 41,500 16.0 12.7 52,000 41,000 55,500 9.2 35,200 1,600 4236500 CHPF4860D6D*+MBVC2000**-1A*+TXV ˄ ¹ ³ ⁵ ⁷ Total CHPF4860D6D*+TXV G*VC81005C*B* 55,500 41,000 15.5 11.8 51,500 40,500 55,000 9.0 30,000 1,800 5038659 CHPF4860D6D*+TXV G*VC80805C*B* 55,000 40,500 15.5 11.8 51,000 40,000 55,500 9.0 30,000 1,590 5038662 CHPF4860D6D*+TXV A*VC81005C*B* 55,500 41,000 15.5 11.8 51,500 40,500 55,000 9.0 30,000 1,800 5038762 CHPF4860D6D*+TXV A*VC80805C*B* 55,000 40,500 15.5 11.8 51,000 40,000 55,500 9.0 30,000 1,590 5038766 Rated in accordance with ANSI/AHRI Standard 210/240 Seasonal Energy Efficiency Ratio TVA Rating: BTU/h @ 75°F/ 63°F - 95°F HSPF = Heating Seasonal Performance Factor CFM at High stage ² ⁴ ⁶ ⁸ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F Rated heating capacity at 47°F outdoor per AHRI 210/240 Heating capacity at 17°F outdoor CFM at Intermediate and low stage Notes • Always check the S&R plate for electrical data on the unit being installed. • When matching outdoor unit to indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman brand gas furnace contains the EEP cooling time delay. 14 www.goodmanmfg.com SS-SSZ16 SS-SSZ16 BK T2 L2 T1 L1 www.goodmanmfg.com CM IO AUX MAIN DFT Y YL PS2 BL Y 1 BR PU RVC LPS BL/PK YL/PK YL/PK PU C C C R R C BK C C RD RD RD AUX GR SEE NOTE 3 L1 C USE N.E.C. CLASS 2 WIRE NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TE RMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTOR ONLY. 4) CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION 5) 40VA MINIMUM TRANSFORMER IS REQUIRED. 6) COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. FIELD WIRING HIGH VOLTAGE LOW VOLTAGE COMPONENT CODE C --------------- CONTACTOR CADM -------- COMFORT ALERT DIAGNOSTIC MODULE R-DFT CCR ----------- COMPRESSOR CONTACTOR RELAY CH ------------- CRANKCASE HEATER CHS ----------- CRANKCASE HEATER SWITCH CM ------------ OUTDOOR FAN MOTOR CMR ---------- CONDENSER MOTOR RELAY R COMP -------- COMPRESSOR CS ------------- COMPRESSOR SOLENOID DC ------------- DEFROST CONTROL DFT ----------- DEFROST THERMOSTAT DT ------------- DISCHARGE THERMOSTAT HPS ----------- HIGH PRESSURE SWITCH HVDR -------- HIGH VOLTAGE DEFROST RELAY IO -------------- INTERNAL OVERLOAD LPS ---------- LOW PRESSURE SWITCH R LVDR --------- LOW VOLTAGE DEFROST RELAY LVJB --------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN RVC ----------- REVERSING VALVE COIL SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN GR---------------- GREEN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK----------- YELLOW/PINK STRIPE Y C BL/PK BL NOTE 1 X AU S CCR LPS F 1 Y ⚡ C C SA (IF USED) NOTE 2 RCCF SC HPS CNT } C C L2 FIELD LOW VOLTAGE CONNECTIONS C-RV H T2 0140R00171 - B C O-RV RVC PS2 Y DC SEE NOTE 5 & 6 O M AI N X AU CH CM IO 2 SEE NOTE 4 R-PS1 DFT O SR COMP M AI N R CHS IO 5 INDOOR POWER SUPPLY W2 W LVDR DFT DF2 C DF1 HVDR T1 OUTDOOR POWER SUPPLY SEE RATING PLATE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. S BK YL EQUIPMENT GROUND RCCF YL YL BL HERM YL F SC SA (IF USED) NOTE 2 RD MAIN Warning IO COMP PU RD RD RD RD CHS RD L2 T2 CH SEE NOTE 4 RD BR BK L1 T1 BK BK BK BL BL ⚠ R BK YL RD BL/PK PU HPS BL RD Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK BK BK 0 2 W SR HVDR YL/PK C-RV BK OR 0 RD 0-RV WH BK LVDR BL/PK CNT 5 YL/PK R-PS1 R-DFT DFT DF2 DC CCR ALTERNATE DOUBLE POLE CONTACTOR BK RD BK DF1 O W2 R OR WH RD LVJB ALTERNATE DOUBLE POLE CONTACTOR ONLY CONTROL BOX Wiring Diagram 15 Product Specifications Dimensions W D Model H Dimensions W” D” H” SSZ160241A* 29 29 38¼ SSZ160361A* 35½ 35½ 38¼ SSZ160481A* 35½ 35½ 38¼ SSZ160601B* 35½ 35½ 38¼ Accessories Model Description SSZ16 024 SSZ16 036 SSZ16 048 SSZ16 060 X ABK-20 Anchor Bracket Kit* X X X CSR-U-1 Hard-start Kit X X X CSR-U-3 Hard-start Kit FSK01A¹ Freeze Protection Kit X X X X LAKT01A Low-Ambient Kit X X X X X X X X X X OT18-60A² Outdoor Thermostat w/ Lockout Stat X TX2N4A³ TXV Kit X TX3N4³ TXV Kit TX5N4³ TXV Kit * ¹ ² ³ X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0° F with 50% or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device. The TXV should always be sized based on the tonnage of the outdoor unit. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2015 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 16 www.goodmanmfg.com SS-SSZ16