Preview only show first 10 pages with watermark. For full document please download

St50- Order Information Sheet - Fluid Components International

   EMBED


Share

Transcript

Order Information Sheet (OIS) ST50 1755 La Costa Meadows Drive | San Marcos, California 92078 USA 760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250 www.fluidcomponents.com Air/Gas Flow Meter INSTRUCTIONS: To order an ST50, please fill in the numbered Block above with the appropriate Code from the categories below. Once you have determined all specifications, contact an FCI representative or FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is subject to FCI’s approval. Model Number Block No. 1 Description 2 3 4 5 6 7 8 ST 50 - c c c c c c c c 1 2 3 4 7 8 A B C D E F [ BLOCK 1 ] Base Unit, Enclosure Style, Power Supply Enclosures: all aluminum, NEMA4X/IP67 rated, epoxy coated Blind, integral transmitter with two 1/2" FNPT cable entries Blind, integral transmitter with two 1/2" FNPT cable entries Integral transmitter with local digital display, with two 1/2" FNPT cable entries Integral transmitter with local digital display, with two 1/2" FNPT cable entries Remote transmitter with two 1/2" FNPT cable entries and with digital display (specify cable length in Block 8) Remote transmitter with two 1/2” FNPT cable entries and with digital display (specify cable length in Block 8) Blind, integral transmitter with two M20x1.5 cable entries Blind, integral transmitter with two M20x1.5 cable entries Integral transmitter, with local digital display, with two M20x1.5 cable entries Integral transmitter, with local digital display, with two M20x1.5 cable entries Remote transmitter with two M20x1.5 cable entries and with digital display (specify cable length in Block 8) Remote transmitter with two M20x1.5 cable entries and with digital display (specify cable length in Block 8) 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered 18 Vdc to 36 Vdc powered 85 Vac to 265 Vac powered [ BLOCK 2 ] Pipe Installation, Display / Transmitter Mounting Orientation and Flow Direction Horizontal Pipe Code Top mount, display facing forward, flow left-to-right Top mount, display facing forward, flow right-to-left Side mount, display facing up, flow left-to-right Side mount, display facing up, flow right-to-left Side mount, display facing down, flow left-to-right Side mount, display facing down, flow right-to-left  F G H J K L Vertical Pipe Code M N P R Side mount left, display facing forward, flow up Side mount right, display facing forward, flow up Side mount left, display facing forward, flow down Side mount right, display facing forward, flow down For visual representation, refer to FCI drawing number 021263 [ BLOCK 3 ] Process Connection / Ferrule Material 1/2 ” male NPT / Teflon ferrule 1/2 ” male NPT / metal ferrule 3/4 ” male NPT / Teflon ferrule 3/4 ” male NPT / metal ferrule 1 2 3 4 [ BLOCK 4 ] Insertion Length 6 ” [152 mm] maximum “U” length 12 ” [305 mm] maximum “U” length 18 ” [457 mm] maximum “U” length 1 2 3 [ BLOCK 5 ] Gas Medium and Calibration 3 Standard: air/nitrogen calibration 1.25 SFPS to 125 SFPS; 10 psia to 50 psia [0,4 NMPS to 38 NMPS; 0,7 bar (a) to 3,5 bar (a)] 2 Customized: air/nitrogen calibration 0.75 SFPS to 150 SFPS; 10 psia to 50 psia [0,2 NMPS to 46 NMPS; 0.7 bar (a) to 3,5 bar (a)] Standard: air/nitrogen/compressed air calibration 4 SFPS to 400 SFPS; 50 psia to 165 psia [1,2 NMPS to 122 NMPS; 3,5 bar (a) to 11,4 bar (a)] 2,6 Customized: nitrogen/compressed air calibration 2.5 SFPS to 400 SFPS; 50 psia to 165 psia [0,8 NMPS to 122 NMPS; 3,5 bar (a) to 11,4 bar (a)] 6 A B D E [ BLOCK 6 ] Calibration 4 and Calibration Conditions Temperature, Vortab Flow Conditioner, Flat Flow Profile Notes 2. User configures line size, scaled flow range and engineering units in the field with PC, PDA or FCI FC88 Calibrator 3. Must specify actual media (air, nitrogen, or compressed air), range, pipe size and engineering units when ordering Flow Range subject to maximum 100:1 and minimum 10:1 turndown. FCI application data sheet (ADS) must accompany order 4. Calibration accuracy is ±% of reading, ± 0.5% of full scale. 5. Fixed cable length with instrument calibrated together as matched set. Cable may be coiled but not cut. 6. Flow element will be -FPC type with FCI patent-pending flow conditioner. Options and Accessories Standard 2% accuracy calibration and conditions 40 °F to 100 °F [4 °C to 38 °C] Standard 2% accuracy calibration and extended temperature compensation: 0 °F to 250 °F [-18 °C to 121 °C] High accuracy 1% calibration and standard conditions 40 °F to 100 °F [4 °C to 38 °C] High accuracy 1% calibration and extended temperature compensation 0 °F to 250 °F [-18 °C to 121 °C] High accuracy 1% calibration with Vortab (VEL, VFK, VIS, VMR or VSR) High accuracy 1% calibration with Vortab (VIP) High accuracy 1% calibration and extended temperature compensation 0 °F to 250 °F [-18 °C to 121 °C] and Vortab (VEL, VFK, VIS, VMR or VSR) High accuracy 1% calibration and extended temperature compensation 0 °F to 250 °F [-18 °C to 121 °C] and Vortab (VIP) High accuracy 1% calibration, at flat flow profile High accuracy 1% calibration and extended temperature compensation 0 °F to 250 °F [-18 °C to 121 °C] and flat flow profile 0 A M N Q 5 T 6 R U [ BLOCK 7 ] Transmitter Options All Standard None Pulse Output 0 1 [ BLOCK 8 ] Interconnecting Cable Length for Remote Configurations 5 0 A B C W Not required (specify with integral configurations) 10 ′ [3 m] 25 ′ [7,6 m] 50 ′ [15 m] Custom length (cannot exceed 50 ′ [15 m]) Part Number Description Part Number Description 019819-01 020802-01 FC88 014108-02 DM10-N DM10-FC Software Interface Package for PDA/PalmOS PDA, Palm® model TungstenTM E2 Portable Hand-held Communicator PC Interface Communications Kit, For RS232 serial port connection Digital Display/Readout, LCD, 4-20 mA loop powered DM10 with FM and CSA approvals DM10-KIT1 DM10-KIT2 DM15 DM15-ALM DM20 Panel Mount Kit for DM10 2″ (52 mm) Pipe Mount Kit for DM10 (stainless steel) Digital Display/Readout, LED 115/230 Vac powered Same as DM-15 with user programmable alarm limit, relay output Digital Display Readout, 8-digit LCD Pulse totalizer/counter © Copyright 2010 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 12/2011 Doc. No. 01SA011464 E  Application Data Sheet (ADS) ST50 Series Flow Meter 1755 La Costa Meadows Drive | San Marcos, California 92078 USA 760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250 www.fluidcomponents.com Customer Information Customer Name: ____________________________________________________ P.O. No.: _____________________ Customer Order No.: ___________________ Address: __________________________________________________________ __________________________________________________________________ ST 50– Model Number Ordered: ______________________________________________ Contact Name: ______________________________________________________ Phone: ____________________________ Fax: ___________________________ Email: ______________________________________________________________ Tag Numbers: Process Details Instrument Details Application Description Flow Element Mounting For visual representation, refer to FCI drawing number 021263 c Air c Compressed Air c Nitrogen Describe type of application (example: aeration basin line, etc.): ___________________________________________________________________ ___________________________________________________________________ Process Conditions Normal Minimum Maximum Engineering Units Flow Rate: _________ _________ _________ _________________ Temperature: _________ _________ _________ _________________ Horizontal c F: Top mount, display facing forward, flow left-to-right c G: Top mount, display facing forward, flow right-to-left c H: Side mount, display facing up, flow left-to-right c J: Side mount, display facing up, flow right-to-left c K: Side mount, display facing down, flow left-to-right c L: Side mount, display facing down, flow right-to-left Vertical c c c c M: Side mount left, display facing forward, flow up N: Side mount right, display facing forward, flow up P: Side mount left, display facing forward, flow down R: Side mount right, display facing forward, flow down Transmitter Setup Pressure: _________ _________ _________ _________________ Input Power: c 115 Vac Required Dimensions (Include units of measure – inches, mm, etc.) Signal Outputs 1. Pipe/Duct Size: Parameter: c Flow (default) c Temperature c Temperature (default) c Flow b) Inside Diameter: _____________________________ Eng. Units: __________________________ __________________________ 2. Length of mounting adapter/coupling from outside pipe surface: ____________ Zero Value: 4 mA = ____________________ 4 mA = ____________________ 3. Length of straight-run available: ______________________________________ Full Scale: 20 mA = ___________________ 4. Describe nearest upstream and downstream disturbance: Signal Output 3 Pulse Totalizer Output: a) Upstream: __________________________________ c Set as 1 pulse per flow engineering unit c Other – must be preapproved by FCI and described here: ________________________________________________________ a) Outside Diameter: ____________________________ b) Downstream: ________________________________ Other notes about installation: ____________________________________________________________________ c 230 Vac Output 1 4-20 mA 20 mA = ___________________ c 24 Vdc Output 2 4-20 mA ________________________________________________________ Standard Temperature and Pressure Installation details or drawing: 70 °F and 14.7 psia [21,1 °C and 1,013 bar (a)] is the factory calibration default for standard temperature and pressure unless otherwise indicated below. Temperature Other: ___________________________ Pressure ___________________________ Digital Display Setup (Optional) Vortab required? c No c Yes Vortab type? c Flow units matching to process minimum and maximum (default) c 0.0% to 100% c VIP c VIS c VMR c VEL c VFK c VSR © Copyright 2009 Fluid Components International LLC. All rights reserved. Subject to change without notice. Doc. No. 01SA011457 D 8 7 6 5 4 3 2 1 REVISION NOTICE OF PROPRIETARY RIGHTS DESCRIPTION REV This document contains confidential technical data, including trade secrets and proprietary information, which is property of Fluid Components International LLC (FCI). Disclosure of this data to you is expressly conditional upon your assent that its use is limited to use within your company only (and does not include manufacture or processing uses). Any other use is strictly prohibited without prior written consent of FCI. C DATE ECN002415 6/23/2015 INTEGRAL HORIZONTAL MOUNTINGS CODE G: CODE H: CODE J: CODE K: FLOW FLOW SCFM XXXX XXXX XXXX TOP MNT, TOP MNT, VIEW FROM BELOW LOOKING UP FLOW SIDE MOUNT, DISPLAY/BLIND FRONT FORWARD DISPLAY/BLIND FRONT FORWARD FLOW RIGHT TO LEFT FLOW FLOW SIDE MOUNT, DISPLAY/BLIND FRONT UP SIDE MOUNT, DISPLAY/BLIND FRONT UP SIDE MOUNT, DISPLAY/BLIND FRONT DOWN DISPLAY/BLIND FRONT DOWN FLOW LEFT TO RIGHT FLOW RIGHT TO LEFT FLOW RIGHT TO LEFT FLOW LEFT TO RIGHT XXXX FLOW FLOW FLOW LEFT TO RIGHT SCFM D FLOW SCFM FLOW C XXXX 4 FLOW SCFM SCFM XXXX 4 CODE L: SCFM CODE F: D C INTEGRAL VERTICAL MOUNTINGS CODE P: CODE R: FLOW CODE N: XXXX SCFM XXXX FLOW CODE M: SCFM B B SIDE MOUNT LEFT DISPLAY/BLIND FRONT FORWARD SCFM FLOW FLOW XXXX XXXX SCFM SIDE MOUNT RIGHT SIDE MOUNT LEFT DISPLAY/BLIND FRONT FORWARD FLOW UP SIDE MOUNT RIGHT DISPLAY/BLIND FRONT FORWARD FLOW UP DISPLAY/BLIND FRONT FORWARD FLOW DOWN FLOW DOWN 4 FLOW ARROW ON TOP AS SHOWN. A 3. THE LCD DISPLAY CAN BE USER ROTATED AND VIEWED AT ANY 90 DEGREE ORIENTATION. UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES 2. IN REMOTE ELECTRONIC CONFIGURATIONS, THE LOCAL ENCLOSURE WILL BE ORIENTED AS SHOWN WITH SOLID COVER ON BOTH SIDES. INTERCONNECTING TERMINALS LOCATED INSIDE. 1. THIS DRAWING IS GENERIC IN NATURE, FOR SPECIFIC MODEL TYPE, ORIENTATION, CUSTOMER PROCESS CONNECTION, ETC, REFER TO IO&M MANUAL. TOLERANCES DECIMALS ANGULAR NEXT ASSY USED ON APPLICATION .1 .03 .010 1/2 MATERIAL THIRD ANGLE PROJECTION MACH SURFACE FINISH: 125 RMS MAX MACH RAD .030 DO NOT SCALE DRAWING PARTS TO BE FREE OF BURRS & SHARP EDGES 7 6 5 PRODUCT CERT APVL 4 ® FLUID APPROVALS DRAWN COMPONENTS INTERNATIONAL LLC 6/23/2015 Ed Pasqual N/A CONTRACT CHECK N/A Sam Kresch MFG ENGR ENGR N/A Ed Pasqual MATL MGMT NOTES: UNLESS OTHERWISE SPECIFIED 8 .X .XX .XXX APPROVALS N/A MFG AERO QUAL N/A N/A 6/23/2015 NUC QUAL Burt Tanaka 3 SAN MARCOS, CA 92078 TITLE 6/23/2015 ST50/ST51, ASSEMBLY ORIENTATION 6/23/2015 ENGR Nancy Peters QA 6/23/2015 A N/A SIZE D CAGE CODE 64818 DWG NO. SCALE 2 REV 021263 NONE C SHEET 1 1 OF 1