Preview only show first 10 pages with watermark. For full document please download

Standard Cpu Module Specifications C0-01dr-d <---> 8 Dc Input/6 Relay Output Micro Plc

   EMBED


Share

Transcript

Standard CPU Module Specifications C0-01DR-D <---> C0-01DR-D Built-in I/O Specifications - Inputs Inputs per Module Operating Voltage Range Input Voltage Range 8 DC Input/6 Relay Output Micro PLC Input Current Maximum Input Current Wiring Diagram C0-01DR-D 24VDC Input Impedance C1 + X1 X2 X4 RUN C2 ERR X5 OFF Voltage Level X6 X7 X8 Maximum OFF Current + PORT1 TX1 Minimum ON Current + PWR ON Voltage Level + X3 OFF to ON Response RX1 C3 TX2 Y1 L RX2 Y2 L Y3 L Y4 L PORT2 RS-485 PORT3 6-27VDC 6 - 240VAC Y5 L RX3 Y6 L Status Indicators Commons 6-27VDC 6 - 240VAC C4 TX3 ON to OFF Response C0-01DR-D Built-in I/O Specifications - Outputs NOTE: When using Standard CPUs, you must use CLICK programming software version V1.20 or later. Equivalent Input Circuit Internal Module Circuitry Optical Isolator INPUT X1-X4 Typical + 8 (Sink/Source) 24 VDC 21.6-26.4 VDC X1-2: Typ 5 mA @ 24 VDC X3-8: Typ 4 mA @ 24 VDC X1-2: 6.0 mA @ 26.4 VDC X3-8: 5.0 mA @ 26.4 VDC X1-2: 4.7 k @ 24 VDC X3-8: 6.8 k @ 24 VDC X1-2: > 19 VDC X3-8: > 19 VDC X1-2: < 4 VDC X3-8: < 7 VDC X1-2: 4.5 mA X3-8: 3.5 mA X1-2: 0.1 mA X3-8: 0.5 mA X1-2: Typ 5 µs Max 20 µs X3-8: Typ 2 ms Max 10 ms X1-2: Typ 5 µs Max 20 µs X3-8: Typ 3 ms Max 10 ms Logic Side (8 points, green LED) 2 (4 points/common) Isolated Outputs per Module Operating Voltage Range Output Voltage Range Output Type 6 6-240 VAC (47-63 Hz), 6-27 VDC 5-264 VAC (47-63 Hz), 5-30 VDC Relay, form A (SPST) Maximum Current 1 A/point; C3: 4 A/common, C4: 2 A/common Minimum Load Current Maximum Inrush Current OFF to ON Response ON to OFF Response Status Indicators 5 mA @ 5 VDC 3 A for 10 ms < 15 ms < 15 ms Logic Side (6 points, red LED) 2 (4 points/com & 2 points/com) Isolated Commons + 24 VDC General Specifications C1 COM Current Consumption at 24VDC Terminal Block Replacement Part No. Weight To X2-X4 commons Optical Isolator INPUT X5-X8 Typical + + 24 VDC Typical Relay Life (Operations) at Room Temperature C0-01DR-D Temperature Derating Chart C2 COM 8 Internal Module Circuitry 6-27 VDC 6-240 VAC Outputs 4 * 2 OUTPUT Y1-Y4 Typical L C3 * To Y2-Y4 commons 10 50 20 68 30 85 6-27 VDC 6-240 VAC OUTPUT Y5-Y6 Typical C4 40 104 50 55 °C 122 131 °F Surrounding Air Temperature (°C/°F) * Use every other input/output. L 300,000 cycles 50,000 cycles 500,000 cycles 200,000 cycles ON to OFF = 1 cycle 0 0 32 COM 30 VDC Resistive 30 VDC Solenoid 250 VAC Resistive 250 VAC Solenoid 6 Points Equivalent Output Circuit Voltage & Load Type Load Current: 1 A Inputs To X6-X8 commons 140 mA C0-16TB 5.6 oz (160 g) ZipLink Pre-Wired PLC Connection Cables and Modules for CLICK PLC * COM To Y6 common ZL-RTB20 20-pin feed-through connector module 20-pin connector cable ZL-C0-CBL20 (0.5 m length) ZL-C0-CBL20-1 (1.0 m length) ZL-C0-CBL20-2 (2.0 m length) * Varistor Joule Rating: 20 J Volume 13 e1-46 Programmable Controllers 1 - 80 0 - 633 - 0405 CLICK Specifications Company Information Systems Overview CPU Module Specifications Programmable Controllers Field I/O Software C-more & other HMI CPU Module Specifications Basic CPU Control Method I/O Numbering System Ladder Memory (steps) Total Data Memory (words) Contact Execution (boolean) Typical Scan (1k boolean) RLL Ladder Style Programming Run Time Edits Scan CLICK Programming Software for Windows Built-in Communication Ports FLASH Memory Built-in Discrete I/O points Built-in Analog I/O Channels Number of Instructions Available Control Relays System Control Relays Timers Counters Interrupt Subroutines For/Next Loops Math (Integer and Hex) Drum Sequencer Instruction Internal Diagnostics Password Security System Error Log User Error Log Memory Backup Battery Backup Calendar/Clock I/O Terminal Block Replacement Communication Port & Terminal Block Replacement 24 VDC Power Terminal Block Replacement Standard CPU Analog CPU Drives Stored Program/Cyclic execution Stored Program/Cyclic execution Stored Program/Cyclic execution method method method Soft Starters Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed Yes Yes Yes Yes (two RS-232 ports) Yes (two RS-232 ports and one RS-485 port) Yes (two RS-232 ports and one RS-485 port) Standard on CPU 8 inputs, 6 outputs No 21 2000 1000 500 250 Yes (external: 8 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor No ADC p/n C0-16TB Standard on CPU 8 inputs, 6 outputs No 21 2000 1000 500 250 Yes (external: 8 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor + Battery Yes (battery sold separately; part # D2-BAT-1) Yes ADC p/n C0-16TB Standard on CPU 4 inputs, 4 outputs 2 inputs, 2 outputs 21 2000 1000 500 250 Yes (external: 4 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor + Battery Yes (battery sold separately; part # D2-BAT-1) Yes ADC p/n C0-16TB N/A ADC p/n C0-03TB ADC p/n C0-03TB Power ADC p/n C0-4TB ADC p/n C0-4TB ADC p/n C0-4TB Circuit Protection No Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Enclosures Tools Pneumatics Appendix Product Index Part # Index Volume 13 w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c Programmable Controllers e1-33 CLICK Specifications CPU Features Basic and Standard CPUs Analog CPUs Mounting Tab Mounting Tab Sliding Latch PLC Mode Switch Sliding Latch PLC Mode Switch 8 Discrete Input Points LED Status Indicators C0-02DD1-D C1 X1 X2 X3 LED Status Indicators PWR X4 RUN C2 ERR Y1 Y2 Communication Ports PORT1 Y3 TX1 Y4 RX1 +V AD1V 6 Discrete Output Points Standard CPUs also have a third communications port located below Port 2. Communication Ports TX2 AD1II AD1 RX2 AD2V PORT2 PORT3 4 Discrete Inputs 4 Discrete Outputs 2 Analog Inputs AD2II AD2 RS-485 ACOM DA1V TX3 DA1II DA1 RX3 DA2V 2 Analog Outputs DA2II DA2 Sliding Latch Power Terminal 24V 0V N.C. G Mounting Tab Sliding Latch Power Terminal 24V 0V N.C. G Mounting Tab Bottom of CPU (Same on all models) Power al Terminal 24V 0V N.C. G Volume 13 e1-34 Programmable Controllers 1 - 80 0 - 633 - 0405 CLICK Specifications Company Information Systems Overview CPU LED Status Indicators Programmable Controllers Field I/O Basic CPUs Basic CPU POWER LED (Green) On Power Good Off Power Failure Software C-more & other HMI Drives RUN LED (Green) On CPU Run Mode Off CPU Stopped INPUT LEDs (Green) On Input True Off Input False Soft Starters Motors & Gearbox ERROR LED (RED) On Self Diagnostic Error Off No Error Steppers/ Servos OUTPUT LEDs (Red) TX & RX LED (Green) On Comm Port Data Active On Output True Off Output False Motor Controls Proximity Sensors Off No Communication Photo Sensors Limit Switches Standard CPUs Standard CPU POWER LED (Green) On Power Good Off Power Failure Encoders C0-01DD1-D RUN LED (Green) On CPU Run Mode Off CPU Stopped INPUT LEDs (Green) PWR RUN ERR ERROR LED (RED) On Off Self Diagnostic Error No Error On Input True Off Input False PORT1 TX1 RX1 TX2 RX2 OUTPUT LEDs (Red) PORT2 TX & RX LED (Green) On Comm Port Data Active PORT3 RS-485 TX3 Off No Communication On Output True Off Output False Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers RX3 Comm. Terminal Blocks & Wiring AnalogCPUs CPU Analog POWER LED (Green) On Power Good Off Power Failure C0-02DD1-D C1 X1 X2 Power INPUT LEDs (Green) On Input True Off Input False Circuit Protection X3 RUN LED (Green) On CPU Run Mode Off CPU Stopped ERROR LED (RED) On Off Self Diagnostic Error No Error TX & RX LED (Green) PWR X4 RUN C2 ERR Y1 Y2 PORT1 Y3 TX1 Y4 RX1 +V Enclosures OUTPUT LEDs (Red) On Output True Off Output False Tools Pneumatics AD1V TX2 AD1I RX2 AD2V PORT2 PORT3 Appendix AD2I RS-485 ACOM Product Index DA1V TX3 DA1I RX3 DA2V DA2I Part # Index On Comm Port Data Active Off No Communication Volume 13 w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c Programmable Controllers e1-35 Product Dimensions and Installation It is important to understand the installation requirements for your CLICK system. Your knowledge of these requirements will help ensure that your system operates within its environmental and electrical limits. Ground Braid Copper Lugs Panel or Single Point Ground Panel Plan for Safety Star Washers This catalog should never be used as a replacement for the user manual. You can purchase, download free, or view online the user manuals for these products. Manual C0-USER-M is the user manual for the CLICK PLC. This user manual contains important safety information that must be followed. The system installation should comply with all appropriate electrical codes and standards. Star Washers 2 in. 50.8 mm minimum 2 in. 50.8mm minimum 3 in. 76.2 mm minimum NOTE: THERE IS A MIMIMUM CLEARANCE REQUIREMENT OF 2 INCHES(51 MM) BETWEEN THE CLICK PLC AND THE PANEL DOOR OR ANY DEVICES MOUNTED IN THE PANEL DOOR. THE SAME CLEARANCE IS REQUIRED BETWEEN THE PLC AND ANY SIDE OF THE ENCLOSURE. A MINIMUM CLEARANCE OF 3 INCHES (76 MM) IS REQUIRED BETWEEN THE PLC AND A WIREWAY OR ANY HEAT PRODUCING DEVICE. PORT1 TX1 RX1 TX2 RX2 PORT2 RUN PWR RUN ERR CLICK PLCs must be mounted properly to ensure ample airflow for cooling purposes. It is important to follow the unit orientation requirements and to verify that the PLC’s dimensions are compatible with your application. Notice particularly the grounding requirements and the recommended cabinet clearances. STOP Mounting Orientation Air Flow Volume 13 e1-22 Programmable Controllers 1 - 80 0 - 633 - 0405 Product Dimensions and Installation Company Information Systems Overview Latch tabs Connecting the Modules Together Programmable Controllers 3 Field I/O Connecting Modules CLICK CPUs, I/O modules and power supplies connect together using the extension ports that are located on the side panels of the modules (no PLC backplane/base required). 1. Remove extension port covers and slide the latch tabs forward. 2. Align the module pins and connection plug, and press the I/O module onto the right side of the CPU. 3. Slide the latch tabs backward to lock the modules together. Software 2 C-more & other HMI Drives Soft Starters Motors & Gearbox 1 Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Supports up to eight I/O modules Limit Switches Encoders Mounting DIN Rail Mounting Surface Mounting Upper Mounting Tab The CLICK PLC system, which includes the CLICK power supplies, CPU modules, and I/O modules, can be mounted in one of two ways. 1. DIN rail mounted 2. Surface mounted using the built-in upper and lower mounting tabs. Pushbuttons/ Lights Process Power Supply Module These diagrams show the outside dimensions of the CLICK power suppy, CPU, and I/O modules. The CLICK PLC system is designed to be mounted on standard 35mm DIN rail, or it can be surface mounted. Allow proper spacing from components within an enclosure. Maximum system: 0.102 [2.6] Push tab up until... Lower Mounting Tab Click Relays/ Timers Comm. CPU Module 1.37 [34.9] 2.11 [53.5] Terminal Blocks & Wiring I/O Module 1.06 [27] 0.46 [13.5] Power 2.95 [75] Circuit Protection Enclosures Tools 3.35 [85] other Power Supply + CPU + 8 I/O modules. Pressure Sensors Temperature Sensors Pull tab down. Unit Dimensions Current Sensors Pneumatics Appendix 0.16 [4] Product Index " 0.37 [9.4] 0.36 [9.2] Part # Index Dimensions in inches [millimeters] Volume 13 w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c Programmable Controllers e1-23 Product Dimensions and Installation Unit Dimensions Power Supply 1.37 [34.9] 0.10 [2.6] 0.53 [13.5] 2.95 [75] * CLICK POWER SUPPLY OUTPUT 24V 0.5A 3.35 [85] 85 3.64 [92.4] 24V 0V G L N INPUT 100-240V 15VA 50-60Hz * Dimensions in inches [millimeters] 0.16 [4] * Use size M4 screws for top and bottom mounting tab holes. 0.19 [4.8] CPU Module 2.11 [53.5] 0.10 [2.6] * 0.37 [9.4] 2.95 [75] 0.2 [5] CLICK CPU MODULE PWR RUN ERR RUN STOP PORT1 TX1 RX1 3.35 [85] 3.66 [93] TX2 RX2 PORT2 0.36 [9.2] * Use size M4 screws for top and bottom mounting tab holes. Dimensions in inches [millimeters] 0.33 [8.5] I/O Module 1.06 [27] 0.10 [2.6] 0.37 [9.4] 2.95 [75] * CLICK I/O MODULE 3.64 [92.4] 3.35 [85] * 0.16 [4] Dimensions in inches [millimeters] * Use size M4 screws for top and bottom mounting tab holes. Volume 13 e1-24 Programmable Controllers 1 - 80 0 - 633 - 0405 Networking the CLICK PLC Company Information Systems Overview Built-in Communications Ports Programmable Controllers There are LED indicators located to the left of each communication port to indicate when the port is transmitting or receiving. Software Com Port 1 C-more & other HMI Com Port 2 Drives Com Port 3 Standard and Analog CPUs Port 1 Port 1 Pin Descriptions 6 pin RJ12 Phone Type Jack 1 LED Status Indicators Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 38400 (fixed) Parity: Odd Station Address: 1 Data length: 8 bits Stop bit: 1 Protocol: Modbus RTU (slave only) Field I/O 6 All CPUs have two built-in RS-232 commuCom Port 1 nications ports. Standard and Analog CPUs also have one built-in RS-485 communications port. One RS-232 port supports the Modbus RTU protocol only and can be used Com Port 2 as the programming port. The other ports support either Modbus RTU or ASCII Basic CPU protocol. Both RS-232 ports supply 5 VDC, so you can connect a monochrome C-more Micro HMI panel without an additional Com Port 1 Specifications power supply. Use: Programming Port 1 2 3 4 5 6 0V 5V RXD TXD NC 0V Power (-) connection (GND) Power (+) connection Receive data (RS-232) Transmit data (RS-232) No connection Power (-) connection (GND) Off The Comm Port is not sending data. TX1 RX1 TX2 RX1 and RX2 (Green) RX2 On The Comm Port is receiving data. PORT2 Off The Comm Port is not receiving data. Standard and Analog CPUs RUN ERR On The Comm Port is sending data. Off The Comm Port is not sending data. PORT1 TX1 RX1 TX2 RX2 PORT2 RX1, RX2 and RX3 (Green) On The Comm Port is receiving data. Off The Comm Port is not receiving data. 1 2 3 4 5 6 0V 5V RXD TXD RTS 0V Power (-) connection (GND) Power (+) connection Receive data (RS-232) Transmit data (RS-232) Request to send Power (-) connection (GND) PORT3 RS-485 TX3 Use: Serial Communication Physical: 3 pin, RS-485 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits ( ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out Motor Controls Proximity Sensors Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Com Port 3 Specifications Port 1, 2, & 3 LED Status IndicatorsPWR TX1, TX2 and TX3 (Green) Port 2 Pin Descriptions 6 pin RJ12 Phone Type Jack 1 STOP PORT1 Port 2 6 TX1 and TX2 (Green) On The Comm Port is sending data. Steppers/ Servos Limit Switches Com Port 2 Specifications Use: Serial Communication Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits (ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out Motors & Gearbox Photo Sensors Basic CPUs Port 1 & 2 LED Status Indicators Soft Starters Port 3 RS-485 Port 3 Pin Descriptions 1 Signal A + (plus) (RS-485) 2 - (minus) 3 LG Signal B (RS-485) Logic Ground(0 V) Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection RX3 Port Setup Enclosures Tools Use CLICK programming software to easily configure the communication ports. Pneumatics Appendix Product Index Part # Index Volume 13 w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c Programmable Controllers e1-25