Standard CPU Module Specifications C0-01DR-D
<--->
C0-01DR-D Built-in I/O Specifications - Inputs Inputs per Module Operating Voltage Range Input Voltage Range
8 DC Input/6 Relay Output Micro PLC
Input Current Maximum Input Current
Wiring Diagram C0-01DR-D
24VDC
Input Impedance
C1
+
X1 X2 X4
RUN
C2
ERR
X5
OFF Voltage Level
X6 X7 X8
Maximum OFF Current
+
PORT1 TX1
Minimum ON Current
+
PWR
ON Voltage Level
+
X3
OFF to ON Response
RX1
C3 TX2
Y1
L
RX2
Y2
L
Y3
L
Y4
L
PORT2 RS-485
PORT3
6-27VDC 6 - 240VAC
Y5
L
RX3
Y6
L
Status Indicators Commons
6-27VDC 6 - 240VAC
C4
TX3
ON to OFF Response
C0-01DR-D Built-in I/O Specifications - Outputs
NOTE: When using Standard CPUs, you must use CLICK programming software version V1.20 or later. Equivalent Input Circuit Internal Module Circuitry Optical Isolator
INPUT X1-X4 Typical
+
8 (Sink/Source) 24 VDC 21.6-26.4 VDC X1-2: Typ 5 mA @ 24 VDC X3-8: Typ 4 mA @ 24 VDC X1-2: 6.0 mA @ 26.4 VDC X3-8: 5.0 mA @ 26.4 VDC X1-2: 4.7 k @ 24 VDC X3-8: 6.8 k @ 24 VDC X1-2: > 19 VDC X3-8: > 19 VDC X1-2: < 4 VDC X3-8: < 7 VDC X1-2: 4.5 mA X3-8: 3.5 mA X1-2: 0.1 mA X3-8: 0.5 mA X1-2: Typ 5 µs Max 20 µs X3-8: Typ 2 ms Max 10 ms X1-2: Typ 5 µs Max 20 µs X3-8: Typ 3 ms Max 10 ms Logic Side (8 points, green LED) 2 (4 points/common) Isolated
Outputs per Module Operating Voltage Range Output Voltage Range Output Type
6 6-240 VAC (47-63 Hz), 6-27 VDC 5-264 VAC (47-63 Hz), 5-30 VDC Relay, form A (SPST)
Maximum Current
1 A/point; C3: 4 A/common, C4: 2 A/common
Minimum Load Current Maximum Inrush Current OFF to ON Response ON to OFF Response Status Indicators
5 mA @ 5 VDC 3 A for 10 ms < 15 ms < 15 ms Logic Side (6 points, red LED) 2 (4 points/com & 2 points/com) Isolated
Commons
+ 24 VDC
General Specifications
C1 COM
Current Consumption at 24VDC Terminal Block Replacement Part No. Weight
To X2-X4 commons
Optical Isolator
INPUT X5-X8 Typical
+ + 24 VDC
Typical Relay Life (Operations) at Room Temperature
C0-01DR-D Temperature Derating Chart C2 COM
8
Internal Module Circuitry
6-27 VDC 6-240 VAC
Outputs 4
*
2 OUTPUT Y1-Y4 Typical
L
C3
*
To Y2-Y4 commons
10 50
20 68
30 85
6-27 VDC 6-240 VAC OUTPUT Y5-Y6 Typical C4
40 104
50 55 °C 122 131 °F
Surrounding Air Temperature (°C/°F) * Use every other input/output.
L
300,000 cycles 50,000 cycles 500,000 cycles 200,000 cycles
ON to OFF = 1 cycle
0 0 32
COM
30 VDC Resistive 30 VDC Solenoid 250 VAC Resistive 250 VAC Solenoid
6
Points
Equivalent Output Circuit
Voltage & Load Type Load Current: 1 A
Inputs
To X6-X8 commons
140 mA C0-16TB 5.6 oz (160 g)
ZipLink Pre-Wired PLC Connection Cables and Modules for CLICK PLC
*
COM To Y6 common
ZL-RTB20 20-pin feed-through connector module
20-pin connector cable ZL-C0-CBL20 (0.5 m length) ZL-C0-CBL20-1 (1.0 m length) ZL-C0-CBL20-2 (2.0 m length)
* Varistor Joule Rating: 20 J
Volume 13
e1-46
Programmable Controllers
1 - 80 0 - 633 - 0405
CLICK Specifications
Company Information Systems Overview
CPU Module Specifications
Programmable Controllers Field I/O Software C-more & other HMI
CPU Module Specifications Basic CPU Control Method I/O Numbering System Ladder Memory (steps) Total Data Memory (words) Contact Execution (boolean) Typical Scan (1k boolean) RLL Ladder Style Programming Run Time Edits Scan CLICK Programming Software for Windows Built-in Communication Ports FLASH Memory Built-in Discrete I/O points Built-in Analog I/O Channels Number of Instructions Available Control Relays System Control Relays Timers Counters Interrupt Subroutines For/Next Loops Math (Integer and Hex) Drum Sequencer Instruction Internal Diagnostics Password Security System Error Log User Error Log Memory Backup Battery Backup Calendar/Clock I/O Terminal Block Replacement Communication Port & Terminal Block Replacement 24 VDC Power Terminal Block Replacement
Standard CPU
Analog CPU
Drives
Stored Program/Cyclic execution Stored Program/Cyclic execution Stored Program/Cyclic execution method method method
Soft Starters
Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed
Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed
Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed
Yes
Yes
Yes
Yes (two RS-232 ports)
Yes (two RS-232 ports and one RS-485 port)
Yes (two RS-232 ports and one RS-485 port)
Standard on CPU 8 inputs, 6 outputs No 21 2000 1000 500 250 Yes (external: 8 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor
No ADC p/n C0-16TB
Standard on CPU 8 inputs, 6 outputs No 21 2000 1000 500 250 Yes (external: 8 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor + Battery Yes (battery sold separately; part # D2-BAT-1) Yes ADC p/n C0-16TB
Standard on CPU 4 inputs, 4 outputs 2 inputs, 2 outputs 21 2000 1000 500 250 Yes (external: 4 / timed: 4) Yes Yes Yes Yes Yes Yes Yes No Super Capacitor + Battery Yes (battery sold separately; part # D2-BAT-1) Yes ADC p/n C0-16TB
N/A
ADC p/n C0-03TB
ADC p/n C0-03TB
Power
ADC p/n C0-4TB
ADC p/n C0-4TB
ADC p/n C0-4TB
Circuit Protection
No
Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring
Enclosures Tools Pneumatics Appendix Product Index Part # Index
Volume 13
w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c
Programmable Controllers
e1-33
CLICK Specifications CPU Features Basic and Standard CPUs
Analog CPUs
Mounting Tab
Mounting Tab Sliding Latch
PLC Mode Switch
Sliding Latch
PLC Mode Switch 8 Discrete Input Points
LED Status Indicators
C0-02DD1-D C1 X1 X2 X3
LED Status Indicators
PWR
X4
RUN
C2
ERR
Y1 Y2
Communication Ports
PORT1
Y3
TX1
Y4
RX1
+V AD1V
6 Discrete Output Points
Standard CPUs also have a third communications port located below Port 2.
Communication Ports
TX2
AD1II AD1
RX2
AD2V
PORT2
PORT3
4 Discrete Inputs 4 Discrete Outputs
2 Analog Inputs
AD2II AD2 RS-485
ACOM DA1V
TX3
DA1II DA1
RX3
DA2V
2 Analog Outputs
DA2II DA2
Sliding Latch Power Terminal 24V 0V N.C. G
Mounting Tab
Sliding Latch Power Terminal 24V 0V N.C. G
Mounting Tab
Bottom of CPU (Same on all models) Power al Terminal 24V 0V N.C. G
Volume 13
e1-34
Programmable Controllers
1 - 80 0 - 633 - 0405
CLICK Specifications
Company Information Systems Overview
CPU LED Status Indicators
Programmable Controllers Field I/O
Basic CPUs Basic CPU
POWER LED (Green) On
Power Good
Off
Power Failure
Software C-more & other HMI Drives
RUN LED (Green) On
CPU Run Mode
Off
CPU Stopped
INPUT LEDs (Green) On
Input True
Off
Input False
Soft Starters Motors & Gearbox
ERROR LED (RED) On
Self Diagnostic Error
Off
No Error
Steppers/ Servos
OUTPUT LEDs (Red) TX & RX LED (Green) On Comm Port Data Active
On
Output True
Off
Output False
Motor Controls Proximity Sensors
Off No Communication
Photo Sensors Limit Switches
Standard CPUs Standard CPU POWER LED (Green) On
Power Good
Off
Power Failure
Encoders
C0-01DD1-D
RUN LED (Green) On
CPU Run Mode
Off
CPU Stopped
INPUT LEDs (Green) PWR RUN ERR
ERROR LED (RED) On Off
Self Diagnostic Error No Error
On
Input True
Off
Input False
PORT1 TX1 RX1
TX2 RX2
OUTPUT LEDs (Red)
PORT2
TX & RX LED (Green) On Comm Port Data Active
PORT3
RS-485
TX3
Off No Communication
On
Output True
Off
Output False
Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers
RX3
Comm. Terminal Blocks & Wiring
AnalogCPUs CPU Analog
POWER LED (Green) On
Power Good
Off
Power Failure
C0-02DD1-D C1 X1 X2
Power
INPUT LEDs (Green) On
Input True
Off
Input False
Circuit Protection
X3
RUN LED (Green) On
CPU Run Mode
Off
CPU Stopped
ERROR LED (RED) On Off
Self Diagnostic Error No Error
TX & RX LED (Green)
PWR
X4
RUN
C2
ERR
Y1 Y2
PORT1
Y3
TX1
Y4
RX1
+V
Enclosures
OUTPUT LEDs (Red) On
Output True
Off
Output False
Tools Pneumatics
AD1V TX2
AD1I
RX2
AD2V
PORT2
PORT3
Appendix
AD2I RS-485
ACOM
Product Index
DA1V
TX3
DA1I
RX3
DA2V DA2I
Part # Index
On Comm Port Data Active Off No Communication
Volume 13
w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c
Programmable Controllers
e1-35
Product Dimensions and Installation It is important to understand the installation requirements for your CLICK system. Your knowledge of these requirements will help ensure that your system operates within its environmental and electrical limits.
Ground Braid Copper Lugs Panel or Single Point Ground
Panel
Plan for Safety
Star Washers
This catalog should never be used as a replacement for the user manual.
You can purchase, download free, or view online the user manuals for these products. Manual C0-USER-M is the user manual for the CLICK PLC. This user manual contains important safety information that must be followed. The system installation should comply with all appropriate electrical codes and standards.
Star Washers
2 in. 50.8 mm minimum
2 in. 50.8mm minimum
3 in. 76.2 mm minimum
NOTE: THERE IS A MIMIMUM CLEARANCE REQUIREMENT OF 2 INCHES(51 MM) BETWEEN THE CLICK PLC AND THE PANEL DOOR OR ANY DEVICES MOUNTED IN THE PANEL DOOR. THE SAME CLEARANCE IS REQUIRED BETWEEN THE PLC AND ANY SIDE OF THE ENCLOSURE. A MINIMUM CLEARANCE OF 3 INCHES (76 MM) IS REQUIRED BETWEEN THE PLC AND A WIREWAY OR ANY HEAT PRODUCING DEVICE.
PORT1 TX1 RX1
TX2 RX2 PORT2
RUN
PWR RUN ERR
CLICK PLCs must be mounted properly to ensure ample airflow for cooling purposes. It is important to follow the unit orientation requirements and to verify that the PLC’s dimensions are compatible with your application. Notice particularly the grounding requirements and the recommended cabinet clearances.
STOP
Mounting Orientation
Air Flow
Volume 13
e1-22
Programmable Controllers
1 - 80 0 - 633 - 0405
Product Dimensions and Installation
Company Information Systems Overview
Latch tabs
Connecting the Modules Together
Programmable Controllers
3
Field I/O
Connecting Modules
CLICK CPUs, I/O modules and power supplies connect together using the extension ports that are located on the side panels of the modules (no PLC backplane/base required). 1. Remove extension port covers and slide the latch tabs forward. 2. Align the module pins and connection plug, and press the I/O module onto the right side of the CPU. 3. Slide the latch tabs backward to lock the modules together.
Software
2
C-more & other HMI Drives Soft Starters Motors & Gearbox
1
Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors
Supports up to eight I/O modules
Limit Switches Encoders
Mounting
DIN Rail Mounting
Surface Mounting Upper Mounting Tab
The CLICK PLC system, which includes the CLICK power supplies, CPU modules, and I/O modules, can be mounted in one of two ways. 1. DIN rail mounted 2. Surface mounted using the built-in upper and lower mounting tabs.
Pushbuttons/ Lights Process
Power Supply Module
These diagrams show the outside dimensions of the CLICK power suppy, CPU, and I/O modules. The CLICK PLC system is designed to be mounted on standard 35mm DIN rail, or it can be surface mounted. Allow proper spacing from components within an enclosure. Maximum system:
0.102 [2.6]
Push tab up until...
Lower Mounting Tab
Click
Relays/ Timers Comm.
CPU Module
1.37 [34.9]
2.11 [53.5]
Terminal Blocks & Wiring
I/O Module 1.06 [27]
0.46 [13.5]
Power
2.95 [75]
Circuit Protection Enclosures Tools
3.35 [85]
other
Power Supply + CPU + 8 I/O modules.
Pressure Sensors Temperature Sensors
Pull tab down.
Unit Dimensions
Current Sensors
Pneumatics Appendix
0.16 [4]
Product Index
"
0.37 [9.4] 0.36 [9.2]
Part # Index
Dimensions in inches [millimeters] Volume 13
w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c
Programmable Controllers
e1-23
Product Dimensions and Installation Unit Dimensions
Power Supply
1.37 [34.9]
0.10 [2.6]
0.53 [13.5]
2.95 [75]
* CLICK POWER SUPPLY
OUTPUT 24V 0.5A
3.35 [85]
85
3.64 [92.4]
24V 0V G L N INPUT 100-240V 15VA 50-60Hz
*
Dimensions in inches [millimeters]
0.16 [4]
* Use size M4 screws for top and bottom mounting tab holes. 0.19 [4.8]
CPU Module
2.11 [53.5]
0.10 [2.6]
*
0.37 [9.4]
2.95 [75]
0.2 [5]
CLICK CPU MODULE PWR RUN ERR
RUN STOP
PORT1 TX1 RX1
3.35 [85]
3.66 [93]
TX2 RX2 PORT2
0.36 [9.2]
* Use size M4 screws for top and bottom mounting tab holes. Dimensions in inches [millimeters] 0.33 [8.5]
I/O Module
1.06 [27]
0.10 [2.6]
0.37 [9.4]
2.95 [75]
*
CLICK I/O MODULE 3.64 [92.4]
3.35 [85]
*
0.16 [4]
Dimensions in inches [millimeters]
* Use size M4 screws for top and bottom mounting tab holes. Volume 13
e1-24
Programmable Controllers
1 - 80 0 - 633 - 0405
Networking the CLICK PLC
Company Information Systems Overview
Built-in Communications Ports
Programmable Controllers
There are LED indicators located to the left of each communication port to indicate when the port is transmitting or receiving.
Software
Com Port 1
C-more & other HMI
Com Port 2
Drives
Com Port 3 Standard and Analog CPUs
Port 1
Port 1 Pin Descriptions
6 pin RJ12 Phone Type Jack 1
LED Status Indicators
Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 38400 (fixed) Parity: Odd Station Address: 1 Data length: 8 bits Stop bit: 1 Protocol: Modbus RTU (slave only)
Field I/O
6
All CPUs have two built-in RS-232 commuCom Port 1 nications ports. Standard and Analog CPUs also have one built-in RS-485 communications port. One RS-232 port supports the Modbus RTU protocol only and can be used Com Port 2 as the programming port. The other ports support either Modbus RTU or ASCII Basic CPU protocol. Both RS-232 ports supply 5 VDC, so you can connect a monochrome C-more Micro HMI panel without an additional Com Port 1 Specifications power supply. Use: Programming Port
1 2 3 4 5 6
0V 5V RXD TXD NC 0V
Power (-) connection (GND) Power (+) connection Receive data (RS-232) Transmit data (RS-232) No connection Power (-) connection (GND)
Off The Comm Port is not sending data.
TX1 RX1 TX2
RX1 and RX2 (Green)
RX2
On The Comm Port is receiving data.
PORT2
Off The Comm Port is not receiving data.
Standard and Analog CPUs
RUN ERR
On The Comm Port is sending data. Off The Comm Port is not sending data.
PORT1 TX1 RX1
TX2 RX2 PORT2
RX1, RX2 and RX3 (Green) On The Comm Port is receiving data. Off The Comm Port is not receiving data.
1 2 3 4 5 6
0V 5V RXD TXD RTS 0V
Power (-) connection (GND) Power (+) connection Receive data (RS-232) Transmit data (RS-232) Request to send Power (-) connection (GND)
PORT3
RS-485
TX3
Use: Serial Communication Physical: 3 pin, RS-485 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits ( ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out
Motor Controls Proximity Sensors
Encoders Current Sensors Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process
Com Port 3 Specifications
Port 1, 2, & 3 LED Status IndicatorsPWR
TX1, TX2 and TX3 (Green)
Port 2 Pin Descriptions
6 pin RJ12 Phone Type Jack 1
STOP PORT1
Port 2
6
TX1 and TX2 (Green) On The Comm Port is sending data.
Steppers/ Servos
Limit Switches
Com Port 2 Specifications Use: Serial Communication Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits (ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out
Motors & Gearbox
Photo Sensors
Basic CPUs
Port 1 & 2 LED Status Indicators
Soft Starters
Port 3
RS-485
Port 3 Pin Descriptions 1
Signal A + (plus) (RS-485)
2
- (minus)
3
LG
Signal B (RS-485) Logic Ground(0 V)
Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection
RX3
Port Setup
Enclosures Tools
Use CLICK programming software to easily configure the communication ports.
Pneumatics Appendix Product Index Part # Index
Volume 13
w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c
Programmable Controllers
e1-25