Preview only show first 10 pages with watermark. For full document please download

Standards And Approvals For Sirius Innovations

   EMBED


Share

Transcript

© Siemens AG 2011 Standards and approvals 2 SIRIUS controls – contactors and contactor assemblies 4 SIRIUS controls – solid-state switching devices 4 SIRIUS protective devices 8 SIRIUS load feeders and compact starter 12 SIRIUS Circuit Breaker 12 SENTRON 8US busbar systems 12 SENTRON air circuit breakers/ non-automaticair circuit breakers 12 SENTRON molded case circuit breakers 12 SENTRON switch disconnectors 12 SENTRON PAC3200 multifunction measuring instruments 13 ALPHA devices according to UL-Standards 14 BETA devices according to UL-Standard 15 SIRIUS controls – contactors and contactor assemblies 15 SIRIUS controls – solid-state switching devices 15 SIRIUS protective devices 16 SIRIUS load feeders, motor starters and soft starters 16 SIRIUS monitoring and control devices 16 SIRIUS detecting devices 17 SIRIUS commanding and signaling devices 17 SIRIUS transformers 17 SIRIUS power supplies 17 SIDAC reactors and filters Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals The following tables contain a summary of the products/product groups available for delivery, including information on their compliance with the relevant UL, CSA and IEC standards. The corresponding CSA certificate can be displayed by entering the manufacturer and the "CSA Class Nummer" at http://directories.csa-international.org. The certificate can be displayed by entering the E number under "UL File Number" (e.g. E116386) at: http://database.ul.com/cgibin/XYV/template/LISEXT/1FRAME/index.htm. The respective Siemens Reports can be downloaded from http://support.automation.siemens.com. Device Standards and approvals Type UL Standard CCN UL listed CCN UL recognized UL File Nr. 3RT20 1... UL508 NLDX -- E31519 3RT20 2... UL508 NLDX -- E31519 Reversing contactors complete units 3RA23 ... UL508 NLDX -- E31519 Reversing contactor assemblies Assembly kits for making 3-pole contactor assemblies 3RA29 13-2AA1 UL508 -- NLDX2/8 E31519 3RA29 13-2AA2 UL508 -- NLDX2/8 E31519 3RA29 23-2AA1 UL508 -- NLDX2 E31519 3RA29 23-2AA2 UL508 -- NLDX2 E31519 3RA29 13-3.A. UL508 -- NLDX2/8 E31519 3RA29 23-3.A. UL508 -- NLDX2 E31519 Mechanical connectors 3RA29 .2-2H UL508 -- NLDX2 E31519 Function modules for connection to the control system 3RA27 11, 3RA27 12, 3RA29 10-0 UL508 NKCR -- E44653 Contactor Assemblies for Wye-Delta Starting Assembly kits for making 3-pole contactor assemblies 3RA29 .3-2BB. UL508 NLDX -- E31519 Three-phase feeder terminals 3RA29 13-3K UL508 NMTR -- E148698 Three-phase busbars 3RV19 15-1AB UL508 NMTR -- E148698 Links for paralleling, 3-pole (star jumpers) 3RT19 .6-4BA3. UL508 NLDX -- E31519 Function modules for wye-delta starting 3RA28 16-0EW20 UL508 NKCR -- E44653 Accessories for 3RA28 function modules 3RA29 10-0 UL508 NKCR -- E44653 Function modules for contactor assemblies for wye-delta starting for connection to the control system 3RA27 1.-.CA00 UL508 NKCR -- E44653 Accessories for 3RA27 function modules 3RA27 11-0EE0. UL508 NKCR -- E44653 3RA29 10-0 UL508 NKCR -- E44653 Contactors for special applications Contactors for Switching Resistive Loads (AC-1) 3RT23 UL508 NLDX -- E31519 3RT25 Contactors 3RT25 UL508 NLDX -- E31519 Contactor relays with extended operating range for railway applications 3RH21 22-2K.40 UL508 NKCR -- E44653 3RT20 ..-2..4. UL508 NLDX -- E31519 Contactor relays Contactor relays 3RH21, 3RH22, 3RH24 UL508 NKCR -- E44653 Coupling contactors Coupling contactors (Interface) SIRIUS controls – contactors and contactor assemblies Contactors for switching motors Contactors Wiring modules (single) 3RT20 ... UL508 NLDX -- E31519 SIRIUS function modules for direct-on-line starting Solid-state timing relays with semiconductor output, for snapping onto the front 3RA28 1.-..W10 UL508 NKCR -- E44653 Accesories 3RA29 10-0 UL508 NKCR -- E44653 SIRIUS function modules for reversing starting / wye-delta starting Assembly kits for reversing starting 3RA29 13-2AA. UL508 -- NLDX2/7 E31519 3RA29 23-2AA. UL508 -- NLDX2 E31519 3RA29 13-2BB. UL508 -- NLDX2/7 E31519 3RA29 23-2BB. UL508 -- NLDX2 E31519 3RA28 16-0EW20 UL508 NKCR -- E44653 3RA29 1.-0 UL508 NKCR -- E44653 3RA29 10-0 UL508 NKCR -- E44653 Assembly kits for wye-delta starting Function modules for wye-delta starting Accessories 2 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals Catalog CSA IEC IC 10 2011 Standard CSA File Nr. CSA CLass Nr. Standard page CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1, IEC60947-5-1 3/26 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1, IEC 60947-5-1 3/28 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1, IEC 60947-5-1 3/91 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 3/94 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-4-1, IEC 60947-5-1 3/95 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 3/109 CSA C22.2 No.14 012730 3211 37 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 37 IEC 60947-2 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-5-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-5-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-5-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-4-1 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 3/131 CSA C22.2 No.14 012730 3211 04 IEC 60947-4-1 3/148 CSA C22.2 No.14 012730 3211 03 IEC 60947-5-1 3/156 CSA C22.2 No.14 012730 3211 04 IEC 60947-5-1 CSA C22.2 No.14 012730 3211 03 IEC 60947-5-1 3/183 CSA C22.2 No.14 012730 3211 04 IEC 60947-5-1 3/204 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/238 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 3/110 3/239 Siemens UL overview 04/2011 3 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals UL Standard CCN UL listed CCN UL recognized UL File Nr. 3RA27 11-.AA00 UL508 NKCR -- E44653 3RA27 11-.BA00 UL508 NKCR -- E44653 3RA27 11-.CA00 UL508 NKCR -- E44653 3RA29 13-2BB. UL508 NLDX -- E31519 3RA29 23-2BB. UL508 -- NLDX2 E31519 3RA27 11-0EE0. UL508 NKCR -- E44653 3RA29 10-0 UL508 NKCR -- E44653 3RA69 35-0A UL508 NKCR -- E44653 3RA27 11-0EE11 UL508 NKCR -- E44653 3RA69 36-0. UL508 NKCR -- E44653 SIRIUS function modules for AS-Interface Function modules for direct-on-line starting 3RA27 12-.AA00 UL508 NKCR -- E44653 Function modules for reversing starting 3RA27 12-.BA00 UL508 NKCR -- E44653 3RA29 13-2AA. UL508 NLDX -- E31519 3RA29 23-2AA. UL508 -- NLDX2 E31519 3RA27 12-.CA00 UL508 NKCR -- E44653 3RA29 13-2BB. UL508 NLDX -- E31519 3RA29 23-2BB. UL508 -- NLDX2 E31519 Accessories 3RA29 10-0 UL508 NKCR -- E44653 Accessories and Spare Parts Auxiliary switch blocks 3RH29 ... UL508 NKCR -- E44653 Auxiliary switch blocks, delayed 3RA28 ... UL508 NKCR -- E44653 Delay and latching blocks 3RT29 16-2B.01 UL508 NKCR -- E44653 3RT29 26-2P..1 UL508 NKCR -- E44653 3RT29 26-3A.31 UL508 NKCR -- E44653 Surge suppressors 3RT29 .6... UL508 -- NKCR2 E44653 Other function blocks 3RT29 16... UL508 NKCR -- E44653 3RT29 26-1QT00 UL508 -- NKCR2 E44653 3RH29 24-1GP11 UL508 NKCR -- E44653 3RT29 16-4MA10 UL508 NLDX -- E31519 Connection modules for contactors with screw terminals 3RT19 ..-4R.01 UL508 NLDX -- E31519 Coil terminal modules 3RT29 26-4R.1. UL508 NKCR -- E44653 Covers for contactors with ring terminal lug connection 3RT29 16-4EA13 UL508 NKCR -- E44653 3RT29 26-4EB13 UL508 NLDX -- E31519 Safety main current connectors for 2 contactors 3RA29 .6-1A UL508 -- NLDX2 E31519 Links for paralleling 3RT.9 .6-4BB.1 UL508 -- NMTR7 E148698 UL508 NLDX -- E31519 SIRIUS function modules for IO-Link Function modules for direct-on-line starting Function modules for reversing starting Function modules for wye-delta starting Accessories Operator panels Function modules for wye-delta starting Sealable covers Insulation stop for securely holding back the conductor 3RT.9 16-4JA02 insulation on conductors up to 1 mm2 SIRIUS controls – solid-state switching devices Solid-State Contactors 3RF34 ... UL508 NMFT -- E143112 Accessories Link modules for solid-state contactors to motor starter protectors 3RA29 21-1BA00 UL508 NLDX NLDX7 E31519 Insulation stop for securely holding back the conductor 3RT29 16-4JA02 insulation on conductors up to 1 mm2 UL508 NLDX -- E31519 SIRIUS protective devices Motor Starter Protectors For motor protection 3RV20 ... UL508 NLRV -- E47705 - Type E 3RV20 ... UL508 NKJH -- E156943 For motor protection with overload relay function 3RV21 ... UL508 NLRV -- E47705 For starter combinations 3RV23 ... UL508 NLRV -- E47705 For transformer protection 3RV24 ... UL508 NLRV -- E47705 Sirius Circuit Breakers For system protection 3RV27 ... UL489 DIVQ -- E235044 For transformer protection 3RV28 ... UL489 DIVQ -- E235044 4 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals Catalog CSA IEC IC 10 2011 Standard CSA File Nr. CSA CLass Nr. Standard page CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/243 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 50295 CSA-C22.2 No. 14 012730 3211 03 IEC 50295 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 50295 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/258 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/263 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/264 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-5-1 3/265 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-5-1 3/266 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 02 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 37 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 06 IEC 60947-4-3 4/107, 4/110 IEC 60947-4-1 4/108, 4/110 Approved acc. to cULus. 3/244 3/247 3/248 3/267 3/269 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-2 5/15 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-2 5/16 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-2 5/17 CSA C22.2 No.5 012730 1432 01 IEC 60947-2 5/18 CSA C22.2 No.5 012730 1432 01 IEC 60947-2 5/19 5/13 Siemens UL overview 04/2011 5 © Siemens AG 2011 Standards and approvals DeviceDevice Type Standards and approvals UL Mountable accessories Auxiliary switches 3RV29 01... Standard CCN UL listed CCN UL recognized UL File Nr. UL508 NKCR -- E44653 UL489 DIHS -- E250201 Signaling switches 3RV29 21-.M UL508 NKCR -- E44653 Isolator modules 3RV29 28-1A UL508 NKCR -- E44653 Auxiliary releases 3RV29 02... UL489 DIHS -- E250201 UL508 NKCR -- E44653 3RV29 22... UL508 NKCR -- E44653 Busbar accessories Three-phase busbars 3RV19 15... UL508 NMTR -- E148698 Three-phase feeder terminals 3RV29 .5... UL508 NMTR -- E148698 Three-phase feeder terminals for constructing "Type E Starters" 3RV29 25-5EB UL508 NMTR -- E148698 UL508 NLDX NLDX7 E31519 Covers for connection tags 3RV19 15-6AB -- -- -- -- Busbar adapters for 60 mm systems 8US12 51-5... UL508 NMTR NMTR7 E328403 Accessories 8US1... UL508 NMTR NMTR7 E328403 3RV29 infeed system Three-phase busbars with infeed 3RV29 17-1. UL508 NMTR -- E148698 Three-phase busbars for system expansion 3RV29 17-4. UL508 NMTR -- E148698 Plug-in connectors 3RV29 .7-5. UL508 NMTR -- E148698 Contactor bases 3RV29 27-7AA00 UL508 NMTR -- E148698 Terminal blocks 3RV29 17-5D UL508 NMTR -- E148698 Extra-wide expansion plugs 3RV29 17-5E UL508 NMTR -- E148698 Expansion plugs 3RV29 17-5BA00 UL508 NMTR -- E148698 End covers 3RV29 17-6A UL508 NMTR -- E148698 Rotary operating mechanisms Door-coupling rotary operating mechanisms 3RV29 26-0. UL508 NLRV -- E47705 Door-coupling rotary operating mechanisms for arduous 3RV29 26-2. conditions UL508 NLRV -- E47705 UL489 DIHS -- E250201 3RV29 08-0P UL508 NKCR -- E44653 3RV29 28-4AA00 UL508 NLRV -- E47705 UL508 NKCR -- E44653 Mounting accessories Covers Terminal blocks and phase barriers for "Self-Protected Combination Motor Controllers (Type E)" according to UL 508 3RV29 28-1. UL508 NMTR -- E148698 Link modules for motor starter protector to contactor 3RA.9 .1... UL508 NLDX NLDX7 E31519 Link modules for motor starter protector to soft starter and motor starter protector to solid-state contactor 3RA29 .1... UL508 NLDX NLDX7 E31519 Hybrid link modules for motor starter protector to contactor 3RA29 .1... UL508 NLDX NLDX7 E31519 Overload Relays 3RU2 Thermal Overload Relays 3RU21 ... UL508 NKCR -- E44653 Accessories for Thermal Overload Relays Terminal brackets for stand-alone installation 3RU29 .6-3A... UL508 NKCR -- E44653 Mechanical RESET 3RU29 00-1A UL508 NKCR -- E44653 3SX1 335 UL508 NKCR -- E44653 3SB30 00-0EA11 UL508 NKCR -- E44653 Cable releases with holder for RESET 3RU29 00-1. UL508 NKCR -- E44653 Modules for remote RESET, electrical 3RU19 00-2A.71 UL508 NKCR -- E44653 Sealable covers 3RV29 08-0P UL508 NKCR -- E44653 Terminal covers 3RU29 .6... UL508 NKCR -- E44653 3RB3 Solid-State Overload Relays 3RB3. ... UL508 NKCR -- E44653 Accessories for Solid-State Overload Relays Terminal brackets for stand-alone installation 3RU29 .6-3A... UL508 NKCR -- Mechanical RESET 3RB39 80-0A UL508 NKCR NKCR7 E44653 3SX1 335 UL508 NKCR -- E44653 3SB30 00-0EA11 UL508 NKCR -- E44653 Cable releases with holder for RESET 3RB39 80-0. UL508 NKCR NKCR7 E44653 Sealable covers 3RB39 84-0 UL508 NKCR NKCR7 E44653 6 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals Catalog CSA IEC IC 10 2011 Standard page Standard CSA File Nr. CSA CLass Nr. CSA-C22.2 No. 5 012730 1437 01 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-5-1 CSA-C22.2 No. 5 012730 1437 01 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 37 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2 CSA C22.2 No. 14 012730 3211 05 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 5/21 Approved acc. to cULus. IEC 60947-4-1 Approved acc. to cULus. IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-2 CSA-C22.2 No. 5 012730 1437 01 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 03 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-2 CSA-C22.2 No. 14 012730 3211 02 IEC 60947-2 Approved acc. to cULus. IEC 60947-4-1 Approved acc. to cULus. IEC 60947-4-1 Approved acc. to cULus. IEC 60947-4-1 5/22 5/24 5/25 5/28 5/29 5/30 5/31 5/33 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1, IEC 60947-5-1 5/84 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-4-1, IEC 60947-4-2 5/86 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 -- -- -- IEC 60947-4-1, IEC 60947-4-2 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1, IEC 60947-4-2 CSA-C22.2 No. 14 012730 3211 03 IEC60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA C22.2 No 14 012730 3211 03 IEC 60947-4-2 5/103 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-4-1, IEC 60947-4-2 5/106 Approved acc. to cULus. 5/87 IEC 60947-4-2 -- -- -- IEC 60947-4-1, IEC 60947-4-2 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1, IEC 60947-4-2 Approved acc. to cULus. IEC 60947-4-2 Approved acc. to cULus. IEC 60947-4-2 Siemens UL overview 04/2011 7 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals UL Standard CCN UL listed CCN UL recognized UL File Nr. SIRIUS load feeders and compact starter 3RA21 direct-on-line starterss 3RA21 ... UL508 NLDX -- E31519 3RA22 reversing starters 3RA22 ... UL508 NLDX -- E31519 Accessories for 3RA2 Load Feeders, Accessories for motor starter protectors Auxiliary switches for motor starter protectors 3RV29 01... UL489 DIHS -- E250201 UL508 NKCR -- E44653 UL489 DIHS -- E250201 UL508 NKCR -- E44653 3RH29 11-1... UL508 NKCR -- E44653 3RH29 .1-.DA.. UL508 NKCR -- E44653 Connection modules for contactors with screw terminals 3RT19 ..-4R.01 UL 508 NLDX -- E31519 Surge suppressors without LED for contactors UL508 -- NKCR2 E44653 UL508 NLDX NLDX7 E31519 UL508 NLDX NLDX7 E31519 Link modules from motor starter protector to soft starter 3RA29 .1-... UL508 NLDX NLDX7 E31519 Wiring kits for contactors 3RA29 13-2... UL508 NLDX -- E31519 3RA29 23-2... UL508 -- NLDX2 E31519 Safety main current connectors for 2 contactors 3RA29 .6-1A UL508 -- NLDX2 E31519 Side modules for standard mounting rail adapters 3RA19 02-1B UL508 NKJH -- E156943 Busbar adapters for 60 mm systems 8US12 51-5... UL508 NMTR NMTR7 E328403 Device holders for lateral mounting onto busbar adapters for 60 mm system 8US12 50-5A.10 UL508 NMTR NMTR7 E328403 Side modules for widening busbar adapters 8US19 98-2BJ10 UL508 NMTR NMTR7 E328403 Spacers for fixing the load feeder onto the busbar 8US19 98-1BA10 UL508 NMTR NMTR7 E328403 Vibration and shock kits for high vibration and shock loads 8US19 98-1CA10 UL508 NMTR NMTR7 E328403 Connecting wedges 8US19 98-1AA00 UL508 -- NMTR2/8 E328403 Function modules for direct-on-line starting 3RA27 1.-.AA00 UL508 NKCR -- E44653 Function modules for reversing starting 3RA27 1.-.BA00 UL508 NKCR -- E44653 Function modules for wye-delta starting 3RA27 1.-.CA00 UL508 NKCR -- E44653 Accessories for function modules 3RA27 11-0EE0. UL508 NKCR -- E44653 3RA29 10-0 UL508 NKCR -- E44653 3RA69 3.-0. UL508 NKCR -- E44653 3RA27 11-0EE11 UL508 NKCR -- E44653 3RA6 Compact Starters Direct-on-line starters 3RA61 UL508 NLRV -- E47705 Reversing starters 3RA62 UL508 NLRV -- E47705 Direct-on-line starters with IO-Link (width 45 mm) 3RA64 UL508 NLRV -- E47705 Reversing starters with IO-Link (width 90 mm) 3RA65 UL508 NLRV -- E47705 Accessories specially for 3RA6 compact starters Control kits 3RA69 50-0A UL508 NLRV -- E47705 Adapters for screw fixing the compact starter 3RA69 40-0A UL508 NLRV -- E47705 Auxiliary switch blocks for compact starters 3RA69 1.-1A UL508 NKCR -- E44653 Main circuit terminals 3RA69 20-1A UL508 NLRV -- E47705 Control circuit terminals 3RA69 20-1. UL508 NLRV -- E47705 Auxiliary switch blocks for compact starters 3RA69 1.-2A UL508 NKCR -- E44653 Main circuit terminals 3RA69 20-2A UL508 NLRV -- E47705 Control circuit terminals 3RA69 20-2. UL508 NLRV -- E47705 Accessories especially for 3RA64, 3RA65 compact starters with IO-Link Additional connection cables (flat) for side-by-side 3RA69 3.-0. mounting of up to 4 compact starters UL508 NLRV -- E47705 Operator panels 3RA69 35-0A UL508 NKCR -- E44653 Enabling modules 3RA69 36-0A UL508 NKCR -- E44653 Connection cables (round) for connecting the operator panel 3RA69 33-0A UL508 NKCR -- E44653 Auxiliary releases for motor starter protectors Accessories for contactors Auxiliary switch blocks for snapping onto the front for contactors Laterally mountable auxiliary switch blocks for contactors 3RV29 02... 3RT29 .6-1... Accessories for the customer assembly of fuseless load feeders Link modules from motor starter protector to contactor 3RA.9 .1... Hybrid link modules from motor starter protector to contactor Operator panels for communication through IO-Link 8 Siemens UL overview 04/2011 3RA29 .1-2F... © Siemens AG 2011 Standards and approvals Catalog CSA IEC IC 10 2011 Standard page Approved acc. to cULus. IEC 60947-4-1 6/16 Approved acc. to cULus. IEC 60947-4-1 6/24 6/32 Standard CSA File Nr. CSA CLass Nr. CSA-C22.2 No. 5 012730 1437 01 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 5 012730 1437 01 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 02 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-5-1 6/34 Approved acc. to cULus. IEC 60947-4-1 6/35 Approved acc. to cULus. IEC 60947-4-1 Approved acc. to cULus. 6/33 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 04 IEC 60947-4-1 6/36 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. 6/38 IEC 60947-2, IEC 60947-4-1 6/39 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 3/243 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-4-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 05, 3211 08 IEC 60947-6-2 6/63 CSA-C22.2 No. 14 012730 3211 05, 3211 08 IEC 60947-6-2 6/64 CSA-C22.2 No. 14 012730 3211 05, 3211 08 IEC 60947-5-1, IEC 60947-6-2 6/65 CSA-C22.2 No. 14 012730 3211 05, 3211 08 IEC 60947-5-1, IEC 60947-6-2 6/66 -- -- -- IEC 60947-6-2 6/68 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 03 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 05 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-5-1 CSA-C22.2 No. 14 012730 3211 08 IEC 60947-6-2 3/244 Siemens UL overview 04/2011 9 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals UL Standard CCN UL listed CCN UL recognized UL File Nr. Terminals for "Self-Protected Combination Motor Controllers (Type E)" according to UL 508 for infeed through parallel wiring with compact starters Terminal blocks type E 3RV19 28-1H UL508 NMTR -E148698 Accessories Three-phase busbars for infeed with 3RA6 3RV19 15-1.B UL508 NMTR -- E148698 Connecting pieces for three-phase busbars 3RV19 15-5DB UL508 NMTR -- E148698 Covers for connection tags of the three-phase busbars 3RV19 15-6AB -- -- -- -- Three-phase feeder terminals for three-phase busbars 3RV19 .5-5.. UL508 NMTR -- E148698 Three-phase feeder terminals for constructing "Type E Starters" according to UL 508 for three-phase busbars 3RV19 25-5EB UL508 NMTR -- E148698 Busbar adapters for 60 mm systems 8US12 11-1NS10 UL508 NMTR NMTR7 E328403 Device holders for lateral mounting along side the busbar adapter for 60 mm systems 8US12 50-1AA10 UL508 NMTR NMTR7 E328403 Door-coupling rotary operating mechanisms for operating the compact starter with closed control cabinet doors 3RV29 26-0. UL508 NLRV -- E47705 3RA69 70-3. UL508 NKCR -- E44653 Three-phase infeeds and expansion modules 3RA68 1.-8A., 3RA68 30-5AC UL508 NMTR -- E148698 Expansion modules 3RA68 2.-0A. UL508 NMTR -- E148698 Accessories for infeed systems for 3RA6s PE infeeds 25/35 mm2 3RA68 60-.A. UL508 NMTR -- E148698 PE pick-offs 6/10 mm2 3RA68 70-.A. UL508 NMTR -- E148698 Expansion plugs 3RA68 90-... UL508 NMTR -- E148698 Adapters 45 mm 3RA68 90-0BA UL508 NMTR -- E148698 Terminal blocks 3RV19 17-5D UL508 NMTR -- E148698 Monitoring Relays for Mounting onto 3RT2 Contactors 3RR2 UL508 NKCR -- E44653 Accessories Terminal brackets for stand-alone installation 3RU29 .6-3A.01 UL508 NKCR -- E44653 Sealable covers 3RR29 40 UL508 NKCR -- E44653 Add-on modules for AS-Interface AS-i add-on modules Infeed systems for 3RA6 10 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals Catalog CSA IEC IC 10 2011 page Standard CSA File Nr. CSA CLass Nr. Standard CSA-C22.2 No. 14 012730 3211 02 IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 05 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 CSA C22.2 No. 14 012730 3211 37 IEC 60947-2, IEC 60947-4-1, IEC 60947-6-2 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 Approved acc. to cULus. IEC 60947-2, IEC 60947-4-1 6/70 6/71 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-6-2 CSA-C22.2 No. 14 012730 3211 03 IEC 50295 6/74 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 6/77 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 6/78 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 6/79 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 37 IEC 60439 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-4-1, IEC 60947-5-1 8/59 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-4-1, IEC 60947-4-2 8/60 CSA-C22.2 No. 14 012730 3211 07 IEC 60947-4-1, IEC 60947-5-1 6/80 Siemens UL overview 04/2011 11 © Siemens AG 2011 Standards and approvals The following tables contain a summary of available products/product groups with indication of the UL standards compliedwith. Device Type At http://database.ul.com/cgi-bin/XYV/template/LISEXT/ 1FRAME/index.htm the certificate can be viewed by entering the E number under "UL File Number" (e.g. E116386). Standards and approvals Catalog UL Standard CCN UL listed CCN UL UL recognized File Nr. CSA IEC Standard Standard LV16 LV 1 LV 1T Chapter SIRIUS Circuit Breaker For system protection and transformer protection 3RV17 21, 3RV17 42, 3RV18 21 UL489 DIVQ -- E235044 CSA C22.2 No. 5 IEC 60947-2 2 5 Accessories Auxiliary switches 3RV19 01 UL489/ UL508 DIHS NKCR -- E250201, E44653 CSA C22.2 No. 5, CSA C22.2 No. 14 IEC 60947-5-1 2 5 Auxiliary trip units 3RV19 .2 UL489/ UL508 DIHS NKCR -- E250201, E44653 CSA C22.2 No. 5, CSA C22.2 No. 14 IEC 60947-2 2 5 UL508 -- NMTR2 E148698 CSA C22.2 No. 14/No. 39 IEC 60439-1 3 14 SENTRON 8US busbar systems Busbar systems 8US1 SENTRON air circuit breakers/non-automaticair circuit breakers Up to 5000 A (ACB) 3WL5 UL489 DIVQ -- E231263 -- IEC 60947-2 4 15 SENTRON molded case circuit breakers Up to 1600 A • Circuit breakers (CB) 3VL1 ... 3VL8 UL489 DIVQ -- E10848 CSA C22.2 No. 5 IEC 60947-2 5 -- • Motor circuit protectors (MCP) 3VL2 ... 3VL7 UL489 -- DKPU2 E10848 CSA C22.2 No. 5 IEC 60947-2, 5 IEC 60947-4-1 -- • Non-automatic air circuitbreaker 3VL1 ... 3VL8 UL489 WJAZ -- E68312 CSA C22.2 No. 5 IEC 60947-2 5 -- UL508 NLRV -- E47705 -- IEC 60947-3 -- 17 • Manual motor controllers, circuit 3LD2 breaker inserts and withdrawable circuit breakers UL508 NLRV -- E47705 CSA C22.2 No.14 IEC 60947-3 -- 17 • In molded-plastic enclosure UL508 NLRV -- E47705 CSA C22.2 No.14 IEC 60947-3 -- 17 • In molded-plastic enclosure, 3LD2 .64-0US2 ... UL508 inch screw connection, special 3LD2. 66-0US2 inscription NLRV -- E47705 CSA C22.2 No.14 IEC 60947-3 -- 17 NLRV2 E47705 -- IEC 60947-3 -- 17 SENTRON switch disconnectors Switch disconnectors Switch disconnectors 3KA52 30, 3KA53 30, 3KA55 30, 3KA57 30, 3KA58 30 Motor and maintenance switches 3LD2 .64 ... 3LD2 .66 Switch disconnectors with fuses and fuse switch disconnectors Switch disconnectors with fuses 3KL52 30, UL508 -3KL57 30, 3KL61 30-1AB02, 3KL62 30-1AB02 Fuse switch disconnectors 3KL53 30, 3KL55 30 UL508 -- NLRV2 E47705 -- IEC 60947-3 -- 17 3NP35 301), 3NP40 101), 3NP40 151), 3NP40 161), 3NP40 701), 3NP40 751), 3NP40 761) UL512 -- IZLT2 E220063 -- IEC 60947-3 -- 17 -- E314880 CAN/CSA C22.2 No. 61010.1 IEC 61010-1 -- 13 SENTRON PAC3200 multifunction measuring instruments Multifunction measuring device 1) 7KM21, 7KM93 According to UL for use only as fuse base. 12 Siemens UL overview 04/2011 UL61010-1 PICQ © Siemens AG 2011 Standards and approvals Device Type Standards and approvals Catalog UL Standard CCN UL listed CCN UL UL recognized File Nr. CSA IEC Standard Standard LV16 ET A1 Chapter ALPHA devices according to UL-Standards ALPHA 8HP molded-plastic distribution systems Enclosure base parts 8HP1 101 ... 8HP1 104, 8HP1 107 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 Transparent covers 8HP1 221 ... 8HP1 224, 8HP1 227, 8HP1 232, 8HP1 247 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 Opaque covers 8HP1 201 ... 8HP1 204, 8HP1 212 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 Intermediate frames 8HP1 283, 8HP1 284 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 Sealing frames 8HP1 541, 8HP1 542 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 Cover plates 8HP1 500 UL50 BGUZ -- E125451 -- IEC 60439-1 6 7 8WA1 011-0D..., UL1059 8WA1 011-1BH23, 8WA1 304, 8WA1 305 -- XCFR2 E80027 CSA 6228-01 -- 6 9 8WA1 011-1BF.., UL1059 8WA1 011-1BG.., 8WA1 011-1BK11, 8WA1 011-1BM11, 8WA1 011-1D..., 8WA1 20. -- XCFR2 E80027 CSA 6228-01 -- 6 9 8WA1 011-3D..., 8WA1 011-1BH.. UL1059 -- XCFR2 E80027 CSA 6228-01 -- 6 9 8WA1 011-1P... UL1059 -- XCFR2 E80027 CSA 6228-01 -- 6 9 8WA1 010-1PH01, UL1059 8WA1 011-1PF0, 8WA1 011-1PG.., 8WA1 011-1PH.., 8WA1 011-1PK00, 8WA1 011-1PM00 -- XCFR2 E80027 CSA 6228-01 -- 6 9 -- XCFR2, XCFR8 E80027 -- -- 6 10 ALPHA FIX terminal blocks ALPHA FIX terminals with screw connection 8WA through-type terminals 8WA PE through-type terminals ALPHA FIX terminals with spring-type connection 8WH through-type terminals 8WH2 000-0.... UL1059 Siemens UL overview 04/2011 13 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals Catalog UL Standard CCN UL listed CCN UL UL recognized File Nr. CSA IEC Standard Standard LV16 ET B1 Chapter BETA devices according to UL-Standard Miniature circuit breakers (MCBs) Miniature circuit breakers 5SY4 (MCBs) 5SY6, 5SY7 UL1077 -- QVNU2 E116386 CSA C22.2 No. 235 IEC 60898, IEC 60947-2 7 1 -- 1 5SY8 UL1077 -- QVNU2 E116386 CSA C22.2 No. 235 IEC 60947-2 -- 1 5SP4 UL1077 -- QVNU2 E106582 CSA C22.2 No. 235 IEC 60898, IEC 60947-2 7 1 Additional components: Auxiliary switches 5ST3 0.. UL1077 -- QVNU2 E106582 CSA C22.2 No. 235 IEC 62019 7 1 Miniature circuit breakers (MCBs) 5SJ4 ...-.HG4. UL489 DIVQ -- E243414 CSA C22.2 No. 5-02 IEC 60898, IEC 60947-2 7 1 Busbars and feeder terminals 5ST3 66. UL489 DIVQ DIHS2 E321559 CSA C22.2 No. 5-02 -- 7 1 Class CC fuse systems Class CC fuse holders 3NW7 5.3-0HG UL512 -- IZLT2 E171267 CSA C22.2 No. 39-M -- 7 3 3NW1 ...-0HG, 3NW2 ...-0HG, 3NW3 ...-0HG UL248-4 JDDZ -- E258218 CSA C22.2 No. 248.4 -- 7 3 3NW7 0, 3NW7 1, 3NW7 2 UL512 -- IZLT2 E171267 CSA C22.2 No. 39-M IEC 60269-2 -- 4 3NH3 030, 3NH3 120, 3NH3 230, 3NH3 330, 3NH3 430, 3NH4 030, 3NH4 230 UL512 -- IZLT2 E171267 CSA C22.2 No. 248.1 IEC 60269-1, IEC 60269-2 7 3 3NC3 2..-1, -6, 3NC3 3..-1, -6, 3NE1 ...-0, -1, -2, 3NE3 2, 3NE3 3, 3NE4 1, 3NE8 0..-1, 3NE8 7..-1 UL248-13 -- JFHR2 E167357 CSA C22.2 No. 248.13 IEC 60269-4 7 4 Cylindrical fuse links 3NC1 0, 3NC1 4, 3NC2 2 UL248-13 -- JFHR2 E167357 CSA C22.2 No. 248.13 IEC 60269-4 7 4 Cylindrical fuse holders 3NC1 0, 3NC1 4, 3NC2 2 UL512 -- IZLT2 E220063 CSA C22.2 No. 39-M IEC 60269-2, IEC 60947-3 7 4 SITOR cylindrical fuse bases 3NC1 038 SR60 busbar systems SR60 bus-mounting fuse holders 3NW7 431 UL512 -- IZLT2 E171267 CSA C22.2 No. 233322 -- 3 5 3NW7 43.-0HG UL512 IZLT -- E171267 CSA C22.2 No. 233322 IEC 60269-2 3 5 Switches and indicator lights Switch disconnectors 5TE1 UL508 NLRV -- E302554 -- IEC 60947-3 7 7 Switching devices Insta contactors 5TT5 7 UL508 NLDX -- E303328 -- IEC 60947-4-1, 7 IEC 60947-5-1 8 Timers Digital and mechanical time switches 7LF4 4, 7LF5 3 UL60730-1, -UL60730-2-7, UL917 WGZR2 E301698 CSA C22.2 No. 14 und 177 IEC 60730-1 7 9 Socket outlets Socket outlets 5TE6 804 UL498 -- RTRT2 E258598 CSA C22.2 No. 182.3M -- 7 10 UL863 -- XHNR2 E300537 CSA C22.2 No. 6 und 55 IEC 60255-6 7 12 Class CC fuse links Low-voltage fuse systems Cylindrical fuse holders (standard series) LV HRC fuse bases SITOR semiconductor fuses SITOR LV HRC design Fuses SITOR cylindrical fuse design SR60 bus-mounting fuse holders Single-phase measuring devices Time and pulse counters 7KT5 8 14 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals The following tables contain more standards and approvals for SIRIUS devices from Catalog LV 1 which are not listed in this UL catalog. Device Type Standards and approvals Catalog UL Standard CCN UL listed CCN UL UL recognized File Nr. CSA IEC Standard Standard LV16 LV 1 LV 1T Chapter SIRIUS controls – contactors and contactor assemblies Contactors for switching motors Contactors 3RT10 1 ... 3RT10 4, 3RT10 5.-.A, -.N, -.P, -.Q, 3RT10 6.-.A, -.N, -.P, -.Q, 3RT10 7.-.A, -.N, -.P, -.Q UL508 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 Vacuum contactors 10 ... 250 kW 3RT12 6.-.A, -.N, 3RT12 7.-.A, -.N UL508 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 Vacuum contactors 335 ... 450 kW 3TF68 ..-0C, -1D, -1Q, -8C, UL508 -8D, -8Q, 3TF69 ..-0C, -1D, -1Q, -8C, -8D, -8Q NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 3TD68 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 Contactor assemblies Reversing contactor assemblies UL508 Contactors for special applications For switching resistive loads 3RT14 4., UL508 3RT14 56-.A, -.N, -.P, -.Q, 3RT14 66-.A, -.N, -.P, -.Q, 3RT14 76-.A, -.N, -.P, -.Q With main contacts 4 NO 3TK1 UL508 NLDX -- E31519 -- IEC 60947-4-1 -- 3 4-pole 3RT13, 3RT15 UL508 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 Capacitor contactors 3RT16 UL508 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 3RH11, 3RH12, 3RH14, 3TH42, 3TH43 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Coupling relays Coupling relays (interface) 3RT10, 3RH11 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Coupling relays Width 6.2 mm 3TX7 01. UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Width 6.2 ... 12.5 mm 3TX7 002 ... 3TX7 005 UL508 NKCR NKCR2 E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Width 22.5 mm 3RS18 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Plug-in relays Relay couplers LZX:MT, PT, RT UL508 -- NLDX2 E31519 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 LZS:MT, PT, RT UL508 -- SWIV2 E196546 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 Power relays/Miniature contactors 4-pole 3TG10 ..-0 UL508 NLDX -- E31519 CSA C22.2 No. 14 IEC 60947-4-1 -- 3 Accessories Surge suppressors UL508 -- NKCR2 E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 3 UL508 NMFT -- E143112 CSA C22.2 No. 14 IEC 60947-4-2 -IEC 60947-4-3 4 Motor starter protectors up to 100 A For motor protection 3RV10 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 -- 5 Type E 3RV10 UL508 NKJH -- E156943 CSA C22.2 No. 14 IEC 60947-2 -- 5 For motor protection with overload relay function 3RV11 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 -- 5 For starter combinations 3RV13 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 -- 5 For transformer protection 3RV14 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 -- 5 For fuse monitoring 3RV16 11-0BD10 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 -- 5 Accessories 3RV19 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 5 Remote motorized operating mechanisms, door-coupling rotary operating mechanisms 3RV19 36, 3RV19 46 UL508 NLRV -- E47705 CSA C22.2 No. 14 IEC 60947-2 5 Contactor relays with 3RH11 22-2K, extended operating range for 3T... ..-0L railway applications Contactor relays Contactor relays 3TX7 4, 3TX7 522 SIRIUS controls – solid-state switching devices Solid-state relays, solid-state contactors 3RF2 SIRIUS protective devices Siemens UL overview 04/2011 -- 15 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals Catalog UL Standard CCN UL listed CCN UL UL recognized File Nr. CSA IEC Standard Standard LV16 LV 1 LV 1T Chapter Overload relays Solid-state overload relays 3RB20 ... 3RB23, 3RB29 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-4-2 -- 5 Thermal overload relays 3RU11 1 ... 3RU11 4 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-4-1 -- 5 Accessories 3RU19 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 5 SIRIUS load feeders, motor starters and soft starters Soft starters Solid-state soft starters 3RW30, 3RW31, 3RW30 03, 3RW40, 3RW44 UL508 NMFT -- E143112 CSA C22.2 No. 14 IEC 60947-4-2 -- 6 3RA11, 3RA12 UL508 NLDX NKJH -- E31519 E156943 CSA C22.2 No. 14 IEC 60947-4-1 -- 6 3RK13 22 UL508 NLDX, NMFT -- E31519 E143112 CSA C22.2 No. 14 IEC 60947-4-2, -IEC 60947-4-1 6 ECOFAST ASi motor starters, degree of protection IP65 3RK13 23 UL508 NLDX, NMFT -- E31519 E143112 CSA C22.2 No. 14 IEC 60947-4-2, -IEC 60947-4-1 6 ET 200S motor starters, degree of protection IP20 3RK13 01 UL508 NLDX, NMFT -- E31519 E143112 CSA C22.2 No. 14 IEC 60947-4-2, -IEC 60947-4-1 6 ECOFAST PROFIBUS motor starters, degree of protection IP65 3RK13 03 UL508 NLDX, NMFT -- E31519 E143112 CSA C22.2 No. 14 IEC 60947-4-2, -IEC 60947-4-1 6 Accessories for ECOFAST and ET 200pro, degree of protection IP65 3RK19 UL508 NLDX, NMFT -- E31519 E143112 CSA C22.2 No. 14 IEC 60947-4-2, -IEC 60947-4-1 6 UL508 NLDX, NMFT -- E31519 E143112 -- IEC 60947-4-2, -IEC 60947-4-1 6 SIMOCODE motor management and control devices SIMOCODE pro 3UF7 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-4-1 -- 7 Current transformers 3UF18 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-4-1 -- 7 Timing relays In industrial enclosure, width 22.5 mm 3RP15 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 7 Width 45 mm 3RP20 Fuseless load feeders Load feeders Motor starters ASi motor starters, degree of protection IP65 ET 200S MS, degree of protec- 3RK13 04 tion IP65 SIRIUS monitoring and control devices UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 7 Monitoring relays Temperature monitoring relays 3RS10, 3RS11 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 7 Thermistor motor protection 3RN1 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-8 -- 7 Monitoring relays for electrical 3UG4 and additional measurements UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 7 3RS17 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-1 -- 7 3SE2 100, 3SE2 120 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE3 0 UL508 -- NKCR2 E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE2 200, 3SE2 210, 3SE2 230 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE5 232, 3SE5 234, 3SE5 242, 3SE5 250 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE5 112, 3SE5 114, 3SE5 115, 3SE5 122 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 Interface converters Interface converters/ isolation amplifiers SIRIUS detecting devices Position switches Standard position switches 16 Siemens UL overview 04/2011 © Siemens AG 2011 Standards and approvals Device Type Standards and approvals Catalog UL CSA IEC Standard CCN UL listed CCN UL UL recognized File Nr. Standard Standard LV16 LV 1 LV 1T 3SF1 1 ... 3SF1 3 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE2 120-1X., 3SE2 120-6XX UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE2 240, 3SE2 243/257 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE3 160, 3SE3 180 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE2 83., 3SE2 84., 3SE2 9 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE5 0 UL508 NKCR NKCR2 E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE5 1, 3SE5 2, 3SE5 25, 3SE5 3 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 3SE5 312, 3SE5 322 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 8 Chapter Safety position switches Magnetically operated switches Magnetic monitoring systems 3SE6 SIRIUS commanding and signaling devices Pushbutton units and indicator lights Nominal diameter 16 mm 3SB20, 3SB22 ... 3SB24 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Nominal diameter 22 mm, round range 3SB30, 3SB32, 3SB32 3, UL508 3SB34 (Screw and solder pin connection), 3SB35, 3SB36 NKCR NKCR2 E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Fixing cut-out 26 x 26 mm, square range 3SB31, 3SB33 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Enclosures 3SB38, 3SB38 63-4 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Cable-operated switches Metal enclosures 3SE7 UL508 NKCR -- E44653 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Signaling columns With diameter 50 and 70 mm 8WD4 UL508 NMTR -- E148698 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 Integrated signal lamps With diameter 70 mm 8WD5 UL508 NMTR E148698 CSA C22.2 No. 14 IEC 60947-5-1 -- 9 4AT25 ... 4AT49, 4BT43 ... 4BT47, 4BT50 ... 4BT65, 4AP41 ... 4AP50, 4AU24 ... 4AU49, 4BU42 ... 4BU47, 4BU49 ... 4BU65 UL1561 -- XQNX2 E257859 CSA C22.2, H47 IEC 61558 -- 10 4AJ, 4AM, 4AP, 4AW UL506 -- XPTQ2 E257852 CSA C22.2 No. 66 IEC 61558 -- 10 4AV2, 4AV30 ... 4AV35 UL1012 -- QQFU2 E257861 CSA C22.2 No. 107.1 IEC 61558 -- 11 4EF, 4EV UL506 -- XPTQ2 E257852 CSA C22.2 No. 66 IEC 61558 -- LV 60 4EP, 4EU, 4EF UL508 -- NMTR2 E148698 CSA C22.2 No. 14 IEC 61558 -- LV 60 4EU24 ... 4EU54, 4ET24 ... 4ET54, 4EM42 ... 4EM62, 4EP32 ... 4EP51 UL1561 -- XQNX2 E257859 CSA C22.2, H47 IEC 61558 -- LV 60 4EF15 1 UL1283 -- FOKY2 E70122 CSA C22.2 No. 8 EN 133200 -- LV 60 SIRIUS transformers Transformers SIRIUS power supplies Power supplies SIDAC reactors and filters Reactors and filters Siemens UL overview 04/2011 17