Transcript
Startup Training – TPS5
TPS Startup Training
Siemens
Topics Covered
Visual Inspections
Verify environmental requirements are met
Properly function TPS 5
Test Procedures
Fill out information product information
2
TPS Startup Training
Visual Inspections
Neutral and ground bond needs to be visually inspected.
If bond is loose, missing, or old, tighten, install, or replace bond. Poor neutral to ground bonds account for 99.9% of all surge protection failures.
Surge protection failure due to poor neutral to ground bond integrity will NOT be warranted!
Refer to page two of the installation manual.
Ground bond broken off
Siemens
3
TPS Startup Training
Siemens
Verify Environmental Requirements
This surge protector is designed to operate indoors in an ambient temperature range of -40°°C (-40°°F) to +60°°C (+140°°F) with a relative humidity of 0% to 95%(noncondensing).
Standard enclosure is NEMA 1
Verify installed environment meets this requirement.
Refer to page three of installation manual.
Refer Red Warning Tag attached to disconnect
4
TPS Startup Training
Startup Before energizing. Surge protection must remain off until high-potential insulation testing is finished. Refer to page 6 of manual Once all installation procedures are followed, surge protector can now be energized. All Siemens TPS surge protectors are designed to be virtually maintenance free. Light indicators show protection status. The following slides show different light conditions and what they mean.
Siemens
5
TPS Startup Training
Normal Status Normal 100% function suppressor will have three green lights. The service light will not illuminate nor will the audible alarm sound.
Siemens
6
TPS Startup Training
Testing Status If the unit is in “Normal Mode – All green lights”, pressing the “Test” button will cause the red service light to illuminate and the audible alarm to sound. Also, the green lights remain illuminated during the test. Once the “Test” button is released, the service light stops illuminating, and the audible alarm will stop. The green phase lights will still illuminate.
Siemens
7
TPS Startup Training
Fault Condition If the surge protector is damaged or takes a surge hit, it may loose some of it’s protection capabilities. If this is the case, the green phase lights will turn either amber or red depending on how much protection is lost. Also, the audible alarm will sound. When either an amber or red lights occur, you need to contact your supply house to order replacement module.
Siemens
8
TPS Startup Training
Silence Audible Alarm When loss of protection is experienced, a phase light will change state from green to amber or red. Also, the service light will turn on and an audible alarm will sound. To silence the audible alarm, you need to press the silence button. Once this is depressed, the audible alarm will silence, and the audible alarm silence light will illuminate.
Siemens
9
TPS Startup Training
Return To Normal Status Once damaged modules are replaced, the phase light or lights will return to their green state, and the service light will stop illuminating. Also, the audible alarm will stop sounding. If the audible alarm silence switch was depressed to turn off the alarm, the silence alarm light will remain on. You need to depress the silence switch again to activate the audible alarm and turn of the silence alarm light.
Siemens
10