Preview only show first 10 pages with watermark. For full document please download

Stero Sd3

   EMBED


Share

Transcript

Project:___________________________________________ Item No.___________________________________________ Quantity___________________ STERO SD3 DOOR-TYPE DISHWASHER STANDARD FEATURES ● .85 gallons per rack ● 58 racks per hour – hot water sanitizing ● 65 racks per hour – chemical sanitizing ● Timed wash cycles for 1, 2 or 4 minutes ● Digital control status ● 180° final rinse assurance ● Interchangeable upper and lower wash and rinse arms ● Automatic tank fill ● Door actuated start ● Automatic drain closure ● Exhaust fan control and booster activation included ● Stainless steel construction ● Error notification ● Straight-through or corner operation ● Hot water or chemical sanitization ● Pressure gauge OPTIONS & ACCESSORIES ❍ Drain water tempering kit ❍ Electric booster heater ❍ Seismic feet ❍ Single point electrical conversion kit (3-phase only) ❍ Pressure reducing valve ❍ Shock arrestor SD3 Hot Water Sanitizing SD3 Chemical Sanitizing Racks per Hour (Maximum) 58 65 Wash Motor H.P. 2 2 5 KW 5 KW MACHINE RATINGS Electric Heating Unit (Regulated) Electric Booster Heater Rate of Rinse Flow – Gallons per Minute – at 20 PSI Flow Pressure Rinse Cycle – Gallons per Rack – at 20 PSI Flow Pressure Peak Rate of Drain Flow – Gallons per Minute (Initial rate with full tank) Incoming Water Temperature Required (Minimum) ST50401 (09/15) 8.5 KW — 5.1 5.1 .97 – 180°F Minimum .97 – 140°F Minimum 14 14 110°F 140°F Page 1 of 4 STERO SD3 DOOR-TYPE DISHWASHER 26" 24-3/4" 21" CHAMBER OPENING 75-3/4" MAX DOOR HEIGHT P5 E3 E2 35" E5 E1 23-1/4" 17-1/4" 10-3/4" 13-1/4" ELEC. SPECS 208-240/60/1 208-240/60/3 480/60/3 SD3 WITH ELECTRIC HEAT MINIMUM MAXIMUM RATED ­SUPPLY CIRCUIT OVERCURRENT AMPS CONDUCTOR PROTECTIVE AMPACITY DEVICE 43.0 50 50 24.9 30 30 13.4 15 15 BOOSTER AMPACITY RATINGS 8.5KW MINIMUM MAXIMUM ELEC. RATED ­SUPPLY CIRCUIT OVERCURRENT SPECS AMPS CONDUCTOR PROTECTIVE AMPACITY DEVICE 208-240/60/1 35.4 50 50 208-240/60/3 20.4 30 30 480/60/3 10.2 15 15 OPTIONAL SD3 SINGLE POINT ELECTRICAL SERVICE CONNECTION MINIMUM MAXIMUM ELEC RATED SUPPLY CIRCUIT ­OVERCURRENT SPECS. AMPS CONDUCTOR PROTECTIVE AMPACITY ­DEVICE 208-240/60/3 45.4 60 60 480/60/3 23.7 30 30 Page 2 of 4 E4 Electrical and grounding connections must comply with the ­applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. CONNECTION INFORMATION (*AFF - ABOVE FINISHED FLOOR) LEGEND E1 E2 E3 E4 E5 P1 P2 P3 P4 P5 P6 P7 ELECTRICAL CONNECTION: MOTORS & CONTROLS (INCLUDING ELECTRIC HEAT). 1" OR 3/4" CONDUIT HOLE. ELECTRICAL CONNECTION: EXHAUST FAN CONTROL, 1/2" CONDUIT HOLE. (VFC1 & VFC2) 1.5 AMPS @ NAMEPLATE SUPPLY VOLTAGE, “ON” ELECTRICAL CONNECTION: RINSE AGENT & SANITIZER FEEDERS, 1/2" CONDUIT HOLE. (DPS1 & DPS2) 1.5 AMPS @ NAMEPLATE SUPPLY VOLTAGE, (RPS1 & RPS2) 1.5 AMPS @ NAMEPLATE SUPPLY VOLTAGE ELECTRICAL CONNECTION: ELECTRIC BOOSTER, 1" CONDUIT HOLE. ELECTRICAL CONNECTION: EXTERNAL BOOSTER CONTROL 1/2" CONDUIT HOLE. (BSTR1 & BSTR2) 0.1 AMPS @ 120 VAC COMMON WATER CONNECTION: (W/O ELECTRIC BOOSTER) (180°F COMMON WATER CONNECTION: (W/O ELECTRIC BOOSTER) (120°F WATER MIN. CHEMICAL SANITIZING) 3/4" FPT. COMMON WATER CONNECTION: (W/ELECTRIC BOOSTER) (110°F WATER MIN. HOT WATER SANITIZING); 3/4" FPT. DRAIN: 1-1/2" NPT. DETERGENT PROBE SENSOR: REMOVE CAP AND STUD ASSEMBLY TO ACCESS 7/8" HOLE DETERGENT FEEDER: REMOVE CAP PLUG TO ACCESS 7/8" HOLE RINSE AGENT FEEDER: 1/8" NPT, REMOVE 1/8" NPT PIPE PLUG TO ACCESS TAPPED HOLE. SANITIZER FEEDER: (LOW TEMP MODE) 1/8" NPT, REMOVE 1/8" NPT PIPE PLUG TO ACCESS TAPPED HOLE ST50401 (09/15) STERO SD3 DOOR-TYPE DISHWASHER 35" 24-1/2" P7 P6 P1 68-1/2" MAX HANDLE HEIGHT 21-5/8" CHAMBER OPENING 16-7/8" DOOR OPENING 58" 52-1/2" 57-1/4" 40-1/4" MIN HANDLE HEIGHT 66-1/2" P4 34" 27" CLEARANCE FOR SERVICE 13" P2 FLOOR 20" CLEARANCE FOR SERVICE P3 22-1/2" WALL P6 6-3/4" 6" P7 P2 5" MIN CLEARANCE TO WALL 11-1/4" 1-1/4" 9-1/2" MIN CLEARANCE FOR CONTROL BOX LID 2-1/4" 15-1/4" 12" 11-1/4" 34" 5-1/2" 25-1/4" P3 28-3/4" NOTICE: Certain materials, including silver, aluminum and pewter are attacked by sodium hypochlorite (liquid bleach) in the chemical sanitizing dishwasher mode of operation. Water hardness should be controlled to 3 grains or less for best results. OVERALL DIMENSIONS:  66-1/2"H x 28-3/4"W x 34"D ST50401 (09/15) 7-1/4" 8" 12-1/2" 24-3/4" MACHINE WEIGHT MODEL NET WEIGHT SHIPPING WEIGHT SD3 270 lbs. 302 lbs. Page 3 of 4 STERO SD3 DOOR-TYPE DISHWASHER 5.686 FROM CHAMBER 20" 20-3/4" 5.686 FROM CHAMBER 31-3/8" MIN. TO WALL DISPLAY 25" PASS THRU INSTALLATION 30" 31-3/8" MIN. TO WALL 15" CLEARANCE FOR SERVICE AFF 27" NOTE: RACK TRACK REPOSITION FOR CORNER INSTALLED UNITS 20" CLEARANCE FOR SERVICE AFF 27" TOP INSIDE VIEW OF MACHINE 20-3/4" DISPLAY CORNER INSTALLATION 30° 9.000 6.000 1-1/4" ROLL 1.00 10.0 0 00 20.0 00 ± 1.37 5 SUGGESTED TABLE DESIGN .125 DRILL Ø .344 HOLE THRU TANK WALL 5/16-18 SST TRUSS HD SCREW 5/16-18 SST LOCKWASHER 5/16-18 SST HEX HD NUT 6.000 6.000 TANK USE SILICONE SEALER BETWEEN TABLE AND LIP OF TANK TO PREVENT LEAKAGE A NOTCH MUST BE ADDED TO BACKSPLASHES OVER 6" HIGH ON CORNER MACHINES TO PREVENT INTERFERENCE WITH DOOR MECHANISM. NOTCH MUST EXTEND 6" FROM FACE OF THE MACHINE. In line with its policy to continually improve its products, Stero reserves the right to change materials and specifications without notice. Page 4 of 4 STERO, a division of Illinois Tool Works, Inc.  1758 Corporate Circle  Petaluma, CA 94954 Phone: 800-762-7600  Fax: 707-762-5036  Website: Stero.com ST50401 (09/15)