Project:___________________________________________ Item No.___________________________________________ Quantity___________________
STERO SG GLASSWASHER
STANDARD FEATURES ● 34 racks per hour rate ● .74 gallons of water per rack ● Chemical sanitizing ● Potable water rinse to remove chemical residue ● Low chemical alert indicators ● Self-priming chemical pumps ● Error notification ● Digital cycle/temperature display ● Interchangeable upper and lower wash and rinse
arms
● Pumped drain ● Pumped rinse ● 12" door opening ● Automatic tank fill ● Chemical pumps standard
OPTIONS & ACCESSORIES ❍ Power cord kits ❍ Drain water tempering kit
SG Chemical Sanitizing
MACHINE RATINGS Racks per Hour Rate
34
Cycle Time – Seconds
105
Tank Heat
1.8 KW
Water Usage Per Rack – Gallons
.74
Peak Drain Flow – Gallons per Minute
4.0
Incoming Water Temperature Required (minimum)
HEAT OUTPUT, BTU/HR. MODEL LATENT SENSIBLE SG 1900 800
MODEL
VOLTS/HERTZ/PHASE
SG
120/60/1
RATED AMPS 15.4
MODEL SG
120°
SHIPPING WEIGHTS DOMESTIC NET WEIGHT SHIPPING WEIGHT 150 lbs. 170 lbs.
MIN SUPPLY CKT CONDUCTOR AMPACITY 20
MAX PROTECTIVE DEVICE 20
NOTE: FOR SUPPLY CONNECTIONS, USE COPPER WIRE ONLY RATED AT 90°C MINIMUM ACCESSORY CORD KIT AVAILABLE FOR ALL MACHINES.
ST50407 (02/15)
Page 1 of 4
STERO SG GLASSWASHER
23 15/16"
E1
P2
P1 1-1/2" TRADE SIZE PIPE MIN. REDUCED DOWN TO 3/4" FPT CONNECTION (BY CUSTOMER)
WALL
34 3/16"
P2
3
P2
RECOMMENDED 23" OR LESS FLOOR LINE
E1
9" MIN
RECOMMENDED WATER SERVICE ROUGH-IN 1/2" TRADE SIZE PIPE MIN. W/SHUTOFF VALVE, LINE STRAINER & 3/4" MALE GARDEN HOSE FITTING (BY CUSTOMER).
1 1/8" 21 11/16" CHEMICAL BOTTLES MAY BE LOCATED ON EITHER SIDE OF MACHINE
TRIM STRIP (OPTIONAL)
27 3/4"
DETERGENT & RINSE-AID CHLORINE SANITIZER
34 5/8"
41 3/16" SERVICE CLEARANCE MIN
6 7/16"
12" MAX LOADING HEIGHT
17"
ADDITIONAL CLEARANCE REQUIRED TO SLIDE UNIT FORWARD FOR SERVICE ONLY
21 11/16"
1 3/8"
MODELS: SG 36" 00-950420 REV B
26 11/16" 39 9/16"
NOTES: Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Required flowing water pressure to the dishmachine is 15-65 PSIG. If pressures higher than 65 PSIG are present, a pressure regulating valve must be installed in the water line to the dishmachine (by others). Pressure gauge not required on pumped rinse machines. Important: The chemical containers should be placed no higher than 16" above floor. If chemical containers are to be placed in cabinet adjacent to machine, a 1/2" dia. hole is required in the cabinet to run chemical supply line. Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing chemical to insure proper operation of dishmachine. Certain materials, including silver plate, aluminum and pewter are attacked by sodium hypochlorite (liquid bleach). See instructional manual. Page 2 of 4
1. All vertical machine dimensions taken from floor may be increased by .875" or decreased by .375". 2. Moist air escapes from the door. Use only moisture resistant materials adjacent to dishmachine sides and top. 3. A vent hood is not recommended above the undercounter dishmachine since it does not produce excessive vapors.
PLUMBING NOTES: 1. Water hammer arrestor (meeting ASSE-1010 Standard or equivalent) to be supplied (by others) in common water supply line at service connection. 2. Recommended water hardness to be 3 grains or less for best results. 3. If drain hose is looped above a sink, the loop must not exceed 44" AFF.
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.
CONNECTION INFORMATION (AFF = ABOVE FINISHED FLOOR)
LEGEND E1 ELECTRICAL CONNECTION: 1-3/8" DIA. HOLE FOR 1" TRADE SIZE CONDUIT; 10-5/8" AFF P1 SINGLE FILL AND RINSE CONNECTION: 3/4" FEMALE G ARDEN HOSE FITTING ON 6' LONG HOSE SUPPLIED WITH MACHINE. 120°F WATER MIN. FOR SG, 140°F RECOMMENDED. P2 DRAIN CONNECTION: 5/8" BARB FITTING WITH 6' LONG HOSE SUPPLIED WITH MACHINE. ST50407 (02/15)
STERO SG GLASSWASHER
23 15/16"
E1
P2
P1
1-1/2" TRADE SIZE PIPE MIN. REDUCED DOWN TO 3/4" FPT CONNECTION (BY CUSTOMER)
WALL
E1
RECOMMENDED 31" OR LESS
DETERGENT, RINSE-AID, CHLORINE SANITIZER BOTTLES MAY BE LOCATED UNDER THE MACHINE
P2
3
P2
FLOOR LINE RECOMMENDED WATER SERVICE ROUGH-IN 1/2" TRADE SIZE PIPE MIN. W/SHUTOFF VALVE, LINE STRAINER & 3/4" MALE GARDEN HOSE FITTING (BY CUSTOMER).
21 11/16" TRIM STRIP (OPTIONAL)
27 3/4"
42 1/8"
12" MAX LOADING HEIGHT
48 11/16" SERVICE CLEARANCE MIN 41 11/16"
24 1/2" 13 15/16"
ADDITIONAL CLEARANCE REQUIRED TO SLIDE UNIT FORWARD FOR SERVICE ONLY
1 3/8"
21 11/16" 26 11/16" 39 9/16"
MODELS: SG 42" 00-950420 REV B
NOTES: Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Required flowing water pressure to the dishmachine is 15-65 PSIG. If pressures higher than 65 PSIG are present, a pressure regulating valve must be installed in the water line to the dishmachine (by others). Pressure gauge not required on pumped rinse machines. Important: The chemical containers should be placed no higher than 24" above floor. If chemical containers are to be placed in cabinet adjacent to machine, a 1/2" dia. hole is required in the cabinet to run chemical supply line. Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing chemical to insure proper operation of dishmachine. Certain materials, including silver plate, aluminum and pewter are attacked by sodium hypochlorite (liquid bleach). See instructional manual. ST50407 (02/15)
1. All vertical machine dimensions taken from floor may be increased by .875" or decreased by .375". 2. Moist air escapes from the door. Use only moisture resistant materials adjacent to dishmachine sides and top. 3. A vent hood is not recommended above the undercounter dishmachine since it does not produce excessive vapors.
PLUMBING NOTES: 1. Water hammer arrestor (meeting ASSE-1010 Standard or equivalent) to be supplied (by others) in common water supply line at service connection. 2. Recommended water hardness to be 3 grains or less for best results. 3. If drain hose is looped above a sink, the loop must not exceed 51" AFF.
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing.
CONNECTION INFORMATION (AFF = ABOVE FINISHED FLOOR)
LEGEND E1 ELECTRICAL CONNECTION: 1-3/8" DIA. HOLE FOR 1" TRADE SIZE CONDUIT; 18-1/8" AFF P1 SINGLE FILL AND RINSE CONNECTION: 3/4" FEMALE G ARDEN HOSE FITTING ON 6' LONG HOSE SUPPLIED WITH MACHINE 120°F WATER MIN. FOR SG, 140°F RECOMMENDED. P2 DRAIN CONNECTION: 5/8" BARB FITTING WITH 6' LONG HOSE SUPPLIED WITH M ACHINE. Page 3 of 4
STERO SG GLASSWASHER
In line with its policy to continually improve its products, Stero reserves the right to change materials and specifications without notice. Page 4 of 4
STERO, a division of Illinois Tool Works, Inc. 1758 Corporate Circle Petaluma, CA 94954 Phone: 800-762-7600 Fax: 707-762-5036 Website: Stero.com
ST50407 (02/15)