Strain Gage Measuring Amplifier GSV-2
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax: 03302 559 141,
[email protected], www.me-systeme.de
1
Description The GSV-2 is considered to be the "classic" among the industrial measuring amplifiers for sensors with strain gages. The highest amount of EMV-protection according to stringency level 4 (EN61000-4-2, 61000-4-4, EN50082-2) and standards going beyond these, IP66 housing and compactness are the attributes that are held in high esteem all over the world. Optionally, the GSV is available with display, plug connectors or zero setting button and amplification changing via relay contacts. The measuring amplifier GSV-2 can be used in process monitoring and in weighing technology. Up to 2000 measured values per second can be transmitted via the serial port. It has excellent digital filters. Filtering or averaging of the transmitted measured values is not required. In addition, there is an analog output (0...10V, or ±5V or 4...20mA) available. The analog output can be set to 0 by a digital control input. The balancing range is 200% of the measuring range. For a low-cost measuring amplifier in 24-bit technology, the measuring rate and the outstanding software support are remarkable above all. The extensive software package ME GSV Control is included in delivery. Settings of the measuring amplifier, i.e. measurement rate, switch thresholds or display options are changed either with control characters or via the ME GSV Control software. For software developers, there is a Windows DLL available for integration of the functions. Various special designs, e.g. an automatic zero point re-regulation and a data logger function are available.
2
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax 03302 559 141,
[email protected] , www.me-systeme.de
Models Characteristic data for all versions (basic equipment):
connection via terminal screws; unipolar voltage supply 10V…30V;
GSV-2LS, GSV-2AS, GSV-2ASD, GSV-2FSD
output signal ±5V, optional -5V…+10V; 3,5Hz; 260Hz; 1700Hz analogue filter; adjustable via software; mode with automatic filter selection according to data rate; remote-control zero balancing; two different input sensitivities selectable by jumpers: between 2mV/V and 1mV/V, oder optional between 3.5mV/V and 1mV/V; functions for serial port: RS 232, RS485/RS422 programmable amplification; programmable filter frequencies; threshold switch with open collector output for connection of a relay; programmable hysteresis; software ME GSV Control; additional input 0V…+10V; software, Windows DLL, Labview vi PCB LxWxH 125mm x 53mm x 29mm; contains all functions of basic configuration
LS version:
AS versions:
FSD versions: D versions:
aluminum housing LxWxH 178mm x 64mm x 37mm; environmental protection IP66; metal cable conduit; front panel installation housing front panel cutout according to DIN 43700: 68 +0,7 x 138 +1,0 installation depth: 64mm display illuminated LC display
GSV-2LS
GSV-2AS, GSV-2ASD GSV-2FSD GSV-2ASD GSV-2FSD GSV-2TSD
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax: 03302 559 141,
[email protected], www.me-systeme.de
3
Examples of possible models: LS: PCB + interface AS: Aluminum housing + interface ASD: Aluminum housing + interface + display FSD: Front panel housing + interface + display TSD: Table housing + interface + display xT: Tare button in the cover (possible with all A versions, already present in front panel housing) x4-20: 4-20 mA current output instead of voltage output x0-20: 0-20 mA current output instead of voltage output Interface options: USB Port for TSD TCP/IP interface (possible with all S versions) Protocol options: Standard: binary protocol with 5 bytes ("comma", "status byte"," H byte", "M byte",L byte") Text protocol via configuration software selectable: 6 digits with decimal point, space, unit, CR, LF e.g. +01.2345 kgCRLF Type
Output voltage in analog filter, volts preselection in Hz GSV-2LS 010 250 GSV-2AS -5+5 250 GSV-2FSD -5+5 250 Ordering designation e.g.: GSV-2LS 010/250/2
Input sensitivity in Additional mV/V options 2 3.5 2
The input sensitivity can be modified between 2.0 and 1mV/V or optionally between 3.5 and 1mV/V in all model versions by use of a jumper. Standard version is GSV-2AS -5+5/250/2.
4
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax 03302 559 141,
[email protected] , www.me-systeme.de
Technical Data (at UB = 12…26V DC within nominal temperature range) Model GSV-2LS / GSV-2AS Accuracy class 0.1 analog
GSV-2ASD / FSD / TSD
Unit
0.1
digital Measurement ranges
0.05
Analog output
±1 (JP1 on1, 5V sensor supply) ±2 or ±3.5 (via software and JP1 on 2, 2.5V sensor supply) 0.25; 0.50; 1.00; 2.00; 4.00 (via software)
mV/V mV/V
Connectable full bridges Bridge supply voltage Input impedance Common mode rejection
4 x 350 2.5 / 5 > 20 / 300pF
Ohm V MOhm
DC
> 120 > 100 < 0.02
Display / serial output
100Hz Linearity deviation Temperature influence on the zero point per 10K Temperature influence on measuring sensitivity per 10K refer. to measured value Analog output Display / digital Output filter analog output 3dB cut-off-frequency analog, Bessel, 2nd order
0.05
4 x 350 2.5 / 5 > 20 / 300pF
>1 20 > 100 < 0.02 measurement range 1mV/V: < 0.4 typ. 0.2 measurement range 2mV/V: < 0.2 typ. 0.1
mV/V
dB dB % v.E. % v.E. % v.E.
< 0.1; typ. 0.05 < 0.01; typ. 0.005
< 0.1; typ. 0.05 <0.01; typ. 0.005
% %
3.5; 260; 1700 (via softw.)
3.5; 260; 1700 (via softw.)
Hz
0.06..1700
0.06..1700
Hz
0.3125..2000 >30000 parts >150000 parts
0.3125..2000 >30000 parts >150000 parts
Hz
Output filter digital 3dB cut-off-frequency digital and display, Measuring rate digital Resolution peak values RMS Analog output usable output range at: Nominal range 0…10V
-5 ...+10 4) -5...+5 47 8
Nominal range ±5V Output resistance Minimum load resistance Analog input Input voltage range Input resistance Control lines1) automatic zero balancing
0…10 56
V V Ohm kOhm 0…10 56
low level: < 1.4,high level: > 3.4 (active high)
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax: 03302 559 141,
[email protected], www.me-systeme.de
V kOhm V
5
Model
GSV-2LS /
GSV-2ASD / FSD / TSD
Unit
GSV-2AS Switching output for threshold switch Saturation voltage Interface Baud rate (delivery status) Operating voltage Nominal range Operating range2) Current consumption
200mA / 30V < 1.0 RS 232/RS422 38400 (8N1)
200mA / 30V < 1.0 RS 232/RS422 38400 (8N1)
11…30 10...32 < 120
11..30 10...32 < 120
V DC Bits/s V DC V DC mA
< 180 last setting last setting manufacturer's setting manufacturer's setting 6 parameter sets 6 parameter sets - programmable threshold value with hysteresis - programmable amplification - programmable balancing of the end value (scaling function) - programmable zero balancing -10…+65 0…+503)
mA
Storage temperature range Dimensions (L x W x H)
-40…+85
°C
PCB Housing Environmental protection of the housing variants (DIN 40 050)
125 x 53 x 27
with display illumination Parameter memory Other functions for the serial output
Nominal temperature range
-20…+70
mm
180 x 65 x 36
180 x 65 x 40
IP66
IP40
1) for Version LS und AS, optionally, 2 additional control cables 2) temperature range and accuracy restricted 3) display with extended temperature range optional 4) supply voltage for 10V output voltage must be at least 15V Absolute limiting values (all voltages with reference to supply ground) -200…+100V Operating voltage: +200V Single pulse 200ms: Differential input:
-4…+12V
Sensor inputs:
-4…+12V
Control lines:
-30…+30V
Analog input:
-20…+20V
6
°C
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax 03302 559 141,
[email protected] , www.me-systeme.de
mm
PCB Dimensions of the GSV-2LS
Housing Dimensions of the GSV-2AS
37
150
178
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax: 03302 559 141,
[email protected], www.me-systeme.de
64
36
138
7
Dimensions of the GSV-2TSD
19
9
158
62
Zero
Front Panel Cutout for GSV-2FSD 138
+1,0
68
+0,7
60
Zero
8
ME-Meßsysteme GmbH, Neuendorfstr. 18a, D-16761 Hennigsdorf Tel 03302 559 282, Fax 03302 559 141,
[email protected] , www.me-systeme.de