Preview only show first 10 pages with watermark. For full document please download

Strobe Messages Guide

   EMBED


Share

Transcript

Strobe Messages Guide Release 5.2 ii Strobe Messages Guide Please direct questions about Strobe or comments on this document to: Strobe Customer Support https://go.compuware.com This document and the product referenced in it are subject to the following legends: Copyright 1984-2017 Compuware Corporation. All rights reserved. Unpublished rights reserved under the Copyright Laws of the United States. U.S. GOVERNMENT RIGHTS-Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in Compuware Corporation license agreement and as provided in DFARS 227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT 1988), FAR 12.212(a) (1995), FAR 52.227-19, or FAR 52.227-14 (ALT III), as applicable. Compuware Corporation. This product contains confidential information and trade secrets of Compuware Corporation. Use, disclosure, or reproduction is prohibited without the prior express written permission of Compuware Corporation. Access is limited to authorized users. Use of this product is subject to the terms and conditions of the user’s License Agreement with Compuware Corporation. Strobe, AutoStrobe, and iStrobe are trademarks or registered trademarks of Strobe. AD/Cycle, BookManager, CICS, DB2, IBM, IMS/ESA, Language Environment, MQSeries, VisualGen, and VTAM are trademarks of International Business Machines Corporation. Microsoft is a registered trademark of Microsoft Corporation. Windows, Windows NT, and Windows 98 are trademarks of Microsoft Corporation. Adobe® Reader® is a trademark of Adobe Systems Incorporated in the United States and/or other countries. All other company and product names are trademarks or registered trademarks of their respective owners. Doc. JAN2017 December 30, 2016 iii Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v How This Manual Is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v How to Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Strobe Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Strobe Option Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Online Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Online Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Other Compuware Application Performance Management Products . . . . . . . . . vi iStrobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi SQL Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Compuware Strobe Customer Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Compuware FrontLine Customer Support Website . . . . . . . . . . . . . . . . . . vii Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Phone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Mail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Corporate Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Compuware APM Service Offerings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii APM Installation Assurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii Application Performance Management Consulting . . . . . . . . . . . . . . . . . .viii Application Performance Assessment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii Chapter 1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Message Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Message Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Message Notation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Return Codes and Severity Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 ABEND Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Viewing Message Descriptions with Strobe/ISPF . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Error Recovery and Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Chapter 2. Messages Produced by the Installation Program . . . . . . . . . . . . . . . . 2-1 Chapter 3. Messages Produced by Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Messages Returned by Strobe Health Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Messages Returned by the Measurement Task . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Messages Returned by the Strobe Indexer Programs . . . . . . . . . . . . . . . . . . . . 3-19 Messages Returned by the Strobe History Manager . . . . . . . . . . . . . . . . . . . . . 3-26 Messages Returned by AutoStrobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32 Messages Returned by the Reporter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46 Online Reporter Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 Sample Dataset Utility Program Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 Messages Returned by Strobe for CA Gen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 SQL Analysis Messages Returned by the Reporter . . . . . . . . . . . . . . . . . . . . . . 3-64 Messages Returned by the Strobe SQL Agent . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66 Messages Returned by Data Collectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-82 Messages Returned in Response to Sampling Control Commands . . . . . . . . . 3-97 Messages Returned by the Session Management Facility. . . . . . . . . . . . . . . . . 3-98 Licensing Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-144 Additional Strobe Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-146 Messages Returned by the Migration Utility . . . . . . . . . . . . . . . . . . . . . . . . . 3-151 iv Strobe Messages Guide Messages Returned by the Session Management Facility for AutoStrobe. . . Messages Returned by Strobe/ISPF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Messages Returned by Attribution Data Collectors . . . . . . . . . . . . . . . . . . . Messages Returned by Strobe Advisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Messages Returned by Strobe SQL Analysis . . . . . . . . . . . . . . . . . . . . . . . . . Messages Returned by Strobe for DB2 Installation Verification Routine . . . 3-157 3-165 3-232 3-248 3-252 3-265 Chapter 4. Messages Returned by Global Monitoring . . . . . . . . . . . . . . . . . . . . . 4-1 Chapter 5. Abend Codes Returned by Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . Strobe Programmed Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Function Codes Returned by Strobe Session Manager . . . . . . . . . . . . . . . . . . . ABEND Codes Returned by the Strobe SQL Agent . . . . . . . . . . . . . . . . . . . . . . 5-1 5-1 5-5 5-7 v Introduction Intro This manual describes the messages and abnormal termination (ABEND) codes produced by the Strobe Application Performance Measurement System, a program product designed for IBM z/OS systems. It lists each message, followed by probable causes, the Strobe system response, and the recommended course of action. For each ABEND code, the manual provides the code number and describes the probable cause of the ABEND. How This Manual Is Organized Chapter 1, “Overview” explains where to find Strobe messages, how to interpret them, and how to act on them. Chapter 2, “Messages Produced by the Installation Program” lists Strobe installation messages in numerical order by message number. Chapter 3, “Messages Produced by Strobe” lists the messages in numerical order by message number and groups them by the component of the Strobe system that issued the message. Chapter 4, “Messages Returned by Global Monitoring” lists the messages in numerical order by message number and groups them by the component of the Global Monitoring feature that issued the message. Chapter 5, “Abend Codes Returned by Strobe” describes abnormal termination (ABEND) codes, lists them numerically by code number, and identifies the reason that the ABEND occurred. How to Use This Manual Use this manual to interpret Strobe messages and ABEND codes. You can also view message explanations online with the Strobe/ISPF Online Message Facility, Option M from the Strobe/ISPF Strobe Options menu. Strobe Library The Strobe base product manuals include: • Strobe Interpretation and Analysis User Guide: Explains how to decide which programs and online regions to measure, when to measure them, and how to interpret the reports in the Strobe Performance Profile. • Strobe Messages Guide: Lists all messages and abnormal termination (ABEND) codes, describes how to interpret them, and in many cases suggests a corrective action. • Strobe Installation and Customization Guide: Explains how to install and maintain Strobe. • Strobe User Guide: Explains how to use Strobe and AutoStrobe to measure application performance. vi Strobe Messages Guide Strobe Option Manuals The separate Strobe option manuals have been combined into a single Strobe Options Guide. This manual describes the optional features of the Strobe Application Performance Measurement System. The manual is divided into parts, with each part describing measurement concepts applicable to, and specific data made available by, each of the following options: • • • • • • • • • • • Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe for Adabas/Natural for Advantage CA-IDMS for CA Gen for CICS for DB2 for IMS for Java for WebSphere Application Server Interface for WebSphere MQ for z/OS UNIX System Services. Online Documentation Strobe manuals are available in HTML and Adobe Acrobat PDF format on CD-ROM and at the Compuware Go customer support Website at https://go.compuware.com. Online Help Strobe products provide the following online information: • Strobe/ISPF Online Tutorials, Option T from the Strobe/ISPF Strobe Options menu • Strobe/ISPF Online Message Facility, Option M from the Strobe/ISPF Strobe Options menu Other Compuware Application Performance Management Products The following products work in conjunction with the Strobe Application Performance Measurement System. These tools extend the benefits of application performance management (APM). iStrobe iStrobe enables you to view and analyze Strobe Performance Profile data on a workstation using a standard Web browser. Easy to install and easy to use, iStrobe guides you through the performance analysis process and offers recommendations for improving performance. iStrobe simplifies the performance analysis of applications that you measure with Strobe. For more information on iStrobe, see the iStrobe online help. SQL Analysis For users of iStrobe and Strobe for DB2, this option provides access path analysis and database and SQL coding recommendations for DB2 applications. SQL Analysis pinpoints the most resource-consumptive static or dynamic SQL statements, explains why these statements might be inefficient, and provides recommendations for improving the performance of the DB2 application. For more information on SQL Analysis, see the Strobe User Guide. Introduction vii Compuware Strobe Customer Support Compuware provides a variety of support resources to make it easy for you to find the information you need. Compuware FrontLine Customer Support Website You can access online information for Compuware products via our FrontLine customer support website at https://go.compuware.com FrontLine provides access to critical information about your Compuware products. You can review frequently asked questions, read or download documentation, access product fixes, or e-mail your questions or comments. The first time you access FrontLine, you are required to register and obtain a password. Registration is free. Contacting Customer Support Phone • USA and Canada: 1-800-538-7822 or 1-313-227-5444. • All other countries: Contact your local Compuware office. Contact information is available at https://go.compuware.com. Web You can report issues via the Quick Link Create & View Support Cases on the Compuware Go home page. Note: Please report all high-priority issues by telephone. Mail Compuware Customer Support Compuware Corporation One Campus Martius Detroit, MI 48226-5099 Corporate Website To access Compuware’s site on the Web, go to http://www.compuware.com. The Compuware site provides a variety of product and support information. Compuware APM Service Offerings For North American customers, for information about current service offerings, please contact your local Compuware sales office or call Compuware Corporate Headquarters at 1-800-compuware (266-7892). You may also visit Compuware’s Mainframe Application Performance Management page at http://www.compuware.com/mainframesolutions/mainframe-application-performance.html. For other international customers, please contact your local Compuware office or Strobe supplier for a complete list of Services offerings. viii Strobe Messages Guide APM Installation Assurance The APM Installation Assurance service assists you in planning for, installing, customizing and using APM products. The service will help you maximize the value and benefits derived from the APM product family. Consulting engineers work closely with your IT personnel to understand your operating environment and your organization’s APM goals. The engineer will assist you in developing a customization and installation plan for Strobe and iStrobe. The engineer will oversee the installation process and verify product readiness. The engineer will also help set up AutoStrobe measurement request schedules, request groups, history records, measurement requests, and will verify the installation of Strobe SQL Analysis. With APM Installation Assurance services, your organization can immediately maximize the value received from your investment in the APM product family. You will also benefit from a fully customized installation that will enhance the product functionality and increase the automation aspects of your APM initiatives. Application Performance Management Consulting The Application Performance Management (APM) Consulting services assist you in identifying and resolving specific performance problems in your business-critical applications. Using Strobe and iStrobe, consulting engineers work closely with your IT personnel to measure an application’s performance, identify performance improvement opportunities and make recommendations for implementing solutions. With APM Consulting services, your organization cannot only resolve problems quickly and effectively, but also gain the skills necessary to prevent application performance degradation in the future. Application Performance Assessment The Application Performance Assessment (APA) service assists you in achieving a higher level of performance for your business-critical applications. Using Strobe and iStrobe, consulting engineers work closely with your IT personnel to evaluate the efficiency of business-critical applications, identify opportunities for improving performance and document the potential savings that can result from implementing recommended solutions. With APA services, you cannot only improve application performance quickly and effectively, but also gain the knowledge and skills necessary to implement and sustain a process-oriented application performance management (APM) program. 1-1 Chapter 1. Overview Chap 1 Strobe issues messages that report on the status of the components of Strobe. Specifically, these messages are returned from the session management facility, its session manager and session requester components, the measurement facility and its subsystem components, and the reporting facility. These components are described in the Strobe User Guide. Messages fall into the following six categories depending upon their level of severity: • Informative messages confirm user inputs, present information about the status of a Strobe function, and announce the completion of processing. • License Management System messages provide information about the licenses you have Compuware products. See the License Manager System documentation for more information about these messages. • Warnings indicate that Strobe has performed the requested operation but had to use some default options. • Conditional errors indicate that Strobe has performed the requested operation, but the information in the Strobe Performance Profile may be incomplete. • Errors indicate that Strobe did not perform the operation, but you can correct and resubmit the request. • Severe errors cause Strobe to terminate processing. The Strobe User Guide contains system recovery information. Message Destination The Strobe session management facility writes its messages to the SYSPRINT dataset and to an operator’s terminal (if the request originated from the terminal). The session management facility also writes all messages, except those produced in response to measurement session status requests, to the Strobe log dataset. The session management facility writes those messages produced in response to measurement session status requests to an operator’s terminal. Strobe/ISPF displays its messages at the top of the panel associated with the error. You can view a longer explanation by pressing the Help PF key. When the session management facility performs an operation and returns more than one message, Strobe/ISPF places the messages in a dataset and invokes the ISPF Browse function. Strobe writes messages produced during reporting and indexing to the SYSPRINT dataset. In addition, Strobe writes messages related to iStrobe to the iStrobe Performance Profile PROFILE.XML file. SQL analysis messages are also sent to the SYSTERM DD. Message Format Messages consist of an identifier followed by a short description of the condition. Message identifiers have a standard format of STRsnnnx, where: • STR is the Strobe prefix. 1-2 Strobe Messages Guide • ssnnnn is a four- to six-alphanumeric character message key, where – ss is the one- to two-alpha character Strobe – The possible values for the severity code and their associated return codes are shown in “Return Codes and Severity Codes” on page 1-2. Strobe follows the message identifier with a short description of the condition. For example: STRI101E The SMS parameter must be "YES" or "NO". STRGM0001I Strobe Monitoring Address Space initialization complete Message Notation Lowercase italicized words represent the names of variables. Brackets, braces, and vertical bars denote phrases that may or may not appear in the actual message: • Brackets [ ] enclose expressions that appear only conditionally. • Braces { } enclose alternative expressions (only one of which appears in the message), separated by vertical bars |. Return Codes and Severity Codes Unless otherwise indicated, the measurement task sets the job step return code to the value provided by the target program when it terminates. The Strobe session management facility, measurement facility, and the reporting facility set a return code to match the severity code in each message. Note: A return code in a message from a LIST or DELETE command issued through Session Requester reflects the highest return code associated with any of the requests targeted by that command. Severity codes and the accompanying return codes are as follows: Severity Return Code Code Meaning I 0 Informative message: occurs during normal operation. W 4 Warning message: indicates the operation is performed, but some information may be missing or some default options may be used. C 8 Conditional error message: indicates a user or system error. The requested action is performed and Strobe continues processing, but information in the Performance Profile reports may not be complete. E 8 Error message: indicates a user or system error. The requested action is not performed. If the measurement task issues such a message, it terminates sampling, but the target program execution continues. S 12 Severe error: indicates a user or system error. Strobe terminates processing. Overview 1-3 ABEND Codes This manual references Strobe abnormal termination (ABEND) codes, which appear when Strobe terminates without completing the measurement session. Chapter 5, “Abend Codes Returned by Strobe” includes a table of ABEND codes, their reason codes, and an explanation of why the ABEND occurred. Viewing Message Descriptions with Strobe/ISPF You can view an explanation of an error message by entering .M in the COMMAND or OPTION field on the panel displaying the message. In addition, you can view an explanation of any message from any panel by entering .M scnn (where scnn is the message key) in the OPTION field on the panel, or by selecting OPTION M from the Strobe Options menu. The messages and the accompanying explanations, system actions, and the recommended response are in Chapter 3, “Messages Produced by Strobe”. To view all the messages for the current request, enter .CVM in the OPTION field or select OPTION L from the Strobe Options menu. Strobe/ISPF presents all the messages in a dataset for you to browse. Error Recovery and Reporting This manual provides a recommended course of action for problems that a user can correct. If the error involves installation defaults, dynamic allocation problems, or other system problems, you should contact the Strobe system programmer. For additional system information, see the Strobe User Guide. 1-4 Strobe Messages Guide 2-1 Chapter 2. Messages Produced by the Installation Program Chap 2 These messages are issued during Strobe installation by the Compuware JCL Customization Facility. For information about installing Strobe, see the Strobe Installation and Customization Guide. STRI001E The dataset name this REXX exec STRINST is being invoked from cannot be automatically determined. Please refer to manual dataset name specification. Explanation: The Strobe JCL customization process requires that the STRINST exec be directly invoked from the ISPF command line. System Action: The Strobe JCL customization process does not execute. User Response: Invoke the Strobe installation exec (STRINST) from the ISPF command line as follows: TSO EX ‘dsn(STRINST)’. where dsn is the dataset name of the Strobe control dataset. STRI002E Do not invoke this REXX exec STRINST by installing it in your SYSPROC DD. Please execute it via: "TSO EX dsn(STRINST)" Explanation: The Strobe JCL customization process requires that the STRINST exec be directly invoked from the ISPF command line. System Action: The Strobe JCL customization process does not execute. User Response: Invoke the Strobe installation exec (STRINST) from the ISPF command line as follows: TSO EX ‘dsn(STRINST)’. where dsn is the dataset name of the Strobe control dataset. STRI003E STRINST. STRINST must be run in an ISPF environment. Please start ISPF prior to running Explanation: The Strobe customization process requires that the STRINST exec be directly invoked from the ISPF command line. System Action: The Strobe JCL customization process does not execute. User Response: Invoke the Strobe installation exec (STRINST) from the ISPF command line as follows: TSO EXEC ‘dsn(STRINST)’. where dsn is the dataset name of the Strobe control dataset. STRI004E The specified installation dataset dsn – could not be located ! Please verify the dataset name and try again. Explanation: The dataset name specified in the message returned a status of DATASET NOT FOUND to the REXX function SYSDSN. System Action: The Strobe JCL customization process does not execute. User Response: Ensure that the installation dataset is available. 2-2 Strobe Messages Guide STRI005E The specified installation dataset dsn – does not contain the REXX exec "STRINST". Please verify the dataset name and try again. Explanation: The dataset name specified in the message returned a status of MEMBER NOT FOUND to the REXX function SYSDSN. System Action: The Strobe JCL customization process does not execute. User Response: Ensure that the installation dataset contains the member STRINST. STRI006E The specified installation dataset dsn – is invalid! Reason: Please verify the dataset name and try again. Explanation: The dataset name specified in the message returned an error status from the REXX function SYSDSN. System Action: The Strobe JCL customization process does not execute. User Response: Correct the error as denoted by the reason text. For more information on the possible reason text refer to the appropriate IBM REXX Reference manual. STRI007E The specified installation dataset dsn – does not contain the REXX exec "STRBUILD". Please verify the dataset name and try again. Explanation: The REXX function SYSDSN returned a status of MEMBER NOT FOUND. System Action: The Strobe JCL customization process does not execute. User Response: Ensure the installation dataset contains the member STRBUILD. STRI020E STRINST. STRBUILD must be run in an ISPF environment. Please start ISPF prior to running Explanation: The Strobe JCL customization process requires that the STRINST exec be directly invoked from the ISPF command line. System Action: The Strobe JCL customization process does not execute. User Response: Invoke the Strobe installation exec (STRINST) from the ISPF command line as follows: TSO EXEC ‘dsn(STRINST)’. where dsn is the dataset name of the Strobe control dataset. STRI021E A fatal I/O error has occurred. Please correct the problem and try again. Explanation: The REXX function EXECIO issued a return code = 20 when attempting to access the installation control dataset. System Action: The Strobe JCL customization process does not execute. User Response: Correct the error as denoted by the return code. For more information on the possible return code refer to the appropriate IBM REXX Reference manual. STRI050E Please select a product for JCL customization. Explanation: No S in the selection field to select a product for JCL customization. System Action: The Strobe JCL customization process does not execute. User Response: Place an S in the selection field to select a product for JCL customization. STRI051E A product feature can not be selected without the product base. Explanation: One or more product features were selected without the product base function also being selected. System Action: The Strobe JCL customization process does not execute. User Response: Place an S in the selection field for the product base function in addition to any product features that were selected. STRI101E The SMS parameter must be "YES" or "NO". Explanation: System Action: You specified an invalid value for the SMS parameter. The Strobe JCL customization process does not process the request. Messages Produced by the Installation Program User Response: STRI102E 2-3 Enter a value of either YES or NO in the SMS parameter field. The DASD unit parameter contains an invalid character. Explanation: The DASD unit parameter you specified contained one or more nonalphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the DASD unit field that contains only alphanumeric STRI103E The DASD volser field contains and invalid character. Explanation: The DASD volser parameter you specified contained one or more nonalphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the DASD volser field that contains only alphanumeric STRI104E The SMP/E Work Unit parameter contains an invalid character. Explanation: The SMP/E work unit parameter you specified contained one or more nonalphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the SMP/E work unit field that contains only alphanumeric STRI105E The tape volser is missing, invalid, or less than 6 characters. Explanation: The tape volser parameter is either missing, contained one or more nonalphanumeric characters, or was less than 6 characters in length. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the tape volser field that is 6 characters long and contains only alphanumeric characters. STRI106E The tape unit parameter contains an invalid character. Explanation: The tape unit parameter you specified contained one or more nonalphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the tape unit field that contains only alphanumeric STRI107E The TMS parameter must be either "YES" or "NO". Explanation: The TMS parameter you specified is invalid. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the TMS field that is either YES or NO. STRI108E The Global High-level qualifier is not a valid dataset name. Explanation: The Global High-level parameter suffixed with .CSI that you specified is invalid, as reported by the SYSDSN REXX function. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a valid value in the Global High-level qualifier field. STRI200E At least one SMS parameter must be specified. Explanation: None of the three possible SMS parameters (STORCLAS, DATACLAS, and MGMTCLAS) must be specified. You must specify at least one. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in at least one of the three SMS parameter fields. 2-4 Strobe Messages Guide STRI201E SMS parameter contains an invalid character. Explanation: characters. The SMS parameter contains one or more non-alphanumeric System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the SMS parameter field that contains only alphanumeric STRI301E The Global CSI dataset name is invalid. Explanation: The Global CSI dataset name you specified is invalid, as reported by the SYSDSN REXX function. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a valid value in the Global CSI dataset name field. STRI302E It is an SMP/E requirement that this dataset name must end with a .CSI Explanation: The Global CSI dataset name you specified is invalid because it does not have .CSI as its last qualifier. System Action: The Strobe JCL customization process does not process the request. User Response: qualifier. Enter a value in the Global CSI dataset name field that has .CSI as its last STRI303E A new Global CSI dataset name cannot be longer than 38 characters. Explanation: The Global CSI dataset name you specified is too long. The dataset name length cannot exceed 38 characters. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Global CSI dataset name field that does not exceed 38 characters in length. STRI304E The CSI set-up field must be "Y" or "N". Explanation: The value you supplied in the Global CSI set-up field is invalid. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Global CSI set-up field that is either Y or N. STRI501E The High-level Qualifier is not valid for a dataset name. Explanation: The High-level Qualifier you specified is invalid, as reported by the SYSDSN REXX function. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the High-level Qualifier field that is valid. STRI601E The Distribution Zone Name is invalid. Explanation: The Distribution Zone name you specified is invalid, it contains one or more non-alphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Distribution Zone name that contains only alphanumeric characters. STRI602E The Distribution Zone CSI dataset name is invalid. Explanation: The dataset name for the Distribution Zone name you specified is invalid, as reported by the REXX SYSDSN function. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Distribution Zone dataset name that is valid. Messages Produced by the Installation Program STRI603E 2-5 It is an SMP/E requirement that the DZone DSN must end with a .CSI Explanation: The Distribution Zone CSI dataset name you specified is invalid because it does not have .CSI as its last qualifier. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Distribution Zone CSI dataset name field that has CSI as its last qualifier. STRI605E The Target Zone Name is invalid. Explanation: The Target Zone name you specified is invalid because it contains one or more non-alphanumeric characters. System Action: The Strobe JCL customization process does not process the request. User Response: characters. Enter a value in the Target Zone name that contains only alphanumeric STRI606E The Target Zone CSI dataset name is invalid. Explanation: The dataset name for the Target Zone name you specified is invalid, as reported by the REXX SYSDSN function. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a valid value for the Target Zone dataset name. STRI607E It is an SMP/E requirement that the Target Zone DSN must end with a .CSI Explanation: The Target Zone CSI dataset name you specified is invalid because it does not have .CSI as its last qualifier. System Action: The Strobe JCL customization process does not process the request. User Response: Enter a value in the Target Zone CSI dataset name field that has .CSI as its last qualifier. 2-6 Strobe Messages Guide 3-1 Chapter 3. Messages Produced by Strobe Chap 3 This chapter contains messages issued by various Strobe components. Messages Returned by Strobe Health Checks These messages are issued by Strobe Health Checks executing under the IBM Health Checker for z/OS. STRKH01I Strobe parameter DB2AUTOFILTER matches the recommended setting of YES. Explanation: Strobe DB2AUTOFILTER parameter is at its optimal setting. System Action: Processing continues. User Response: None STRKH01E Strobe parameter DB2AUTOFILTER does not match the recommended setting of YES. Explanation: System Action: Strobe DB2AUTOFILTER parameter is not at its optimal setting. Processing continues. User Response: See the Strobe Installation and Customization Guide for information regarding this parameter to determine if your site would benefit by changing this parameter. Messages Returned by the Measurement Task The measurement task returns the following messages. STR0115E SAMPLING MODULE modname NOT FOUND - MEASUREMENT SESSION TERMINATED Explanation: System Action: Strobe did not find the sampling routine named modname. The measurement task terminates. User Response: Notify the Strobe system programmer. There has probably been an installation error. STR0117E I/O ERROR LOCATING SAMPLING ROUTINES - MEASUREMENT SESSION TERMINATED Explanation: routines. Strobe encountered an I/O error while issuing a BLDL for the sampling System Action: The measurement task terminates. User Response: Notify the Strobe system programmer. STR0120W DCT ENTRY FOR MODULE module HAS BEEN MARKED INVALID - NOT REENTRANT Explanation: An internal error has occurred. System Action: incomplete. Strobe continues measuring, but measurement data may be invalid or User Response: Contact Compuware Customer Support. STR0123E GETMAIN FAILURE FOR block - MEASUREMENT SESSION TERMINATED Explanation: System Action: Virtual storage is not available for the critical control block block. The measurement task terminates. 3-2 Strobe Messages Guide User Response: Increase the region size so that Strobe can obtain the necessary virtual storage, and then resubmit the request. Contact the Strobe system programmer to obtain Strobe virtual storage requirements. STR0125E PCMG modname INVALID HEADER Explanation: Strobe detected an invalid header in PCMG module modname. System Action: The measurement task terminates. User Response: Contact Customer Support. STR0126E PCMG csectname CSECT NOT FOUND Explanation: Strobe did not find CSECT csectname. System Action: Strobe continues sampling but may issue additional error messages. User Response: Contact Compuware Customer Support. STR0127E PCMG cdename CDE NOT FOUND Explanation: Strobe did not find CDE cdename. System Action: Strobe continues sampling but may issue additional error messages. User Response: Contact Compuware Customer Support. STR0128E PCMG entryname ENTRY NOT FOUND Explanation: Strobe did not find the entry point entryname. System Action: Strobe continues sampling but may issue additional error messages. User Response: Contact Compuware Customer Support. STR0129E STROBE MEASUREMENT MUST BE INVOKED BY THE SESSION MANAGER Explanation: You attempted to run STRBVPH1 and attach the target program as a subtask. You cannot invoke the measurement facility directly; you must use the session manager. System Action: Strobe does not accept the measurement request. User Response: Resubmit the request through the Strobe session manager. STR0134E LICENSE VERIFICATION FAILED RETURN CODE= rc REASON CODE= erc MEASUREMENT SESSION TERMINATED Explanation: Strobe base license has expired. The return code is rc and the error reason code is erc. System Action: Strobe does not initialize. User Response: Refer to additional License Management System messages, and contact Compuware Customer Support. STR0140I MQSERIES COUNTS DISABLED FOR MEASUREMENT Explanation: System Action: Strobe support for MQSeries Counts is not enabled. Strobe continues sampling but will not collect MQSeries counts. User Response: For information about enabling Strobe support for MQSeries counts, contact Compuware Customer Support. STR0144E STROBE TASKTERM ENDED IN ERROR - RTN xx, RS yy Explanation: The measurement completed, but Strobe did not release all of its resources. RTN xx is the decimal number of the subroutine that encountered the error. RS yy is the hexadecimal reason code for the error. System Action: None. User Response: Strobe log. Contact Compuware Customer Support and provide the sample dataset and Messages Produced by Strobe STR0188W 3-3 NOTIFICATION TO FAULT MANAGER OF reason FAILED, RETCODE=xxx Explanation: Strobe was unable to notify the Abend-AID Fault Manager about reason, which can be one of the following: – ABNORMAL BEHAVIOR IN PROGRAM pppppppp OF JOB jjjjjjjj - Abnormal behavior detected during AutoStrobe monitoring of the designated program pppppppp – COMPLETION OF MEASUREMENT rrrr - The completion of the designated measurement. rrrr is the Strobe request number. xxx is the return code returned by the Fault Manager for the notification request. System Action: AutoStrobe monitoring or Strobe’s measurement processing continues. After five occurrences of this message for an AutoStrobe-detected event, AutoStrobe will stop further attempts at fault-manager notification. User Response: STR0189I Notify the Strobe or Abend-AID system programmer. ABEND-AID FAULT MANAGER NOT AVAILABLE Explanation: Strobe attempted to notify the Abend-AID Fault Manager about the detection of an event but the Fault Manager is not active. System Action: continues. AutoStrobe monitoring or Strobe’s measurement-termination processing User Response: Notify the Strobe or Abend-AID system programmer. STR0190E STROBE abendcode ABNORMAL TERMINATION MODULE=modname CSECT=csectname OFFSET=offset Explanation: An ABEND with code abendcode occurred during execution of the Strobe measurement task. The message identifies the module name modname, control section name csectname, and offset offset (in hexadecimal notation) at the time of termination. Additional information about the ABEND appears in the sample dataset.  If Strobe reports modname as SWDA, Strobe was unable to obtain sufficient System Diagnostic Work Area (SDWA) storage and will not report CSECT or OFFSET information. System Action: The measurement session continues or terminates, depending on the site and severity of the error. User Response: STR0191I Notify the Strobe system programmer. csectname CRITERIA MATCHED Explanation: Informational message identifying a Strobe csectname that has reached a specific service criteria. System Action: Measurement session continues. User Response: None. STR0199E INCOMPATIBLE MEASUREMENT SESSION MODULES - STROBE release, modname module_ release Explanation: Strobe attempted to load a measurement session module that has a different release level from that of STRBVPH1, the initial measurement task module. The release level of the initial measurement task module is release, the loaded module is modname, and its release level is module_release. System Action: The data collector terminates, but the measurement task continues. If the problem occurred in a measurement task module, then the measurement task terminates. User Response: occurred. STR0200I Notify the Strobe system programmer. An installation error may have STROBE MEASUREMENT ENDED Explanation: The measurement session terminated normally. The sample dataset is ready for reporting. System Action: Strobe completes processing. User Response: None required. 3-4 Strobe Messages Guide STR0207E GETMAIN FAILURE - MEASUREMENT SESSION TERMINATED Explanation: A measurement task module cannot obtain sufficient storage for its work area. System Action: The measurement task terminates. User Response: Increase the region size and resubmit the request. STR0208E MEASUREMENT TASK UNABLE TO ISSUE ESTAE - MEASUREMENT SESSION TERMINATED Explanation: The measurement task is unable to establish its ABEND protection. System Action: The measurement task terminates. User Response: Notify the Strobe system programmer. STR0209W LNKLST SET CHANGED DURING MEASUREMENT - MODULE MAPPING/ATTRIBUTION MAY BE INCORRECT Explanation: While measuring, Strobe detected a change in the Link List Set. The SETPROG LNKLST,UPDATE,JOB=jobname command was issued. System Action: inaccurate. Strobe continues processing but the module mapping or attribution may be User Response: Resubmit the measurement request. Ensure that the SETPROG LNKLST,UPDATE,JOB=jobname command is not issued while the measurement is active. STR0210W STROBE MEASUREMENT LOOP TIMER HAS BEEN RESET - CPU TIME FOR MEASUREMENT IS INVALID Explanation: While measuring, Strobe detected that its main task timer had been cancelled. The task timer was reset by something other than Strobe's sampling control logic. System Action: Strobe sets its timer to a known state and continues processing. However, the CPU time used by Strobe is no longer accurate. This inaccuracy will be reflected in the CPU times for the user tasks being measured as well as CPU time used by the Strobe measurement task. User Response: None required. Strobe handles the condition and continues with the measurement. However, for more accurate results, the measurement should be repeated. STR0212I ATTRIBUTION DRIVER DISABLED FOR MEASUREMENT OF THIS ADDRESS SPACE TYPE Explanation: You requested to measure a DB2 DDF job. Attribution reports are not available for DDF address spaces. System Action: Strobe continues measuring, but no attribution information will be collected. User Response: STR0295E None required. MEASUREMENT TASK PRIORITY ALTERED - MEASUREMENT SESSION TERMINATED Explanation: The Strobe measurement is no longer the highest priority task in the measured address space. System Action: The measurement task terminates. User Response: Resubmit the measurement request. The system will initialize it with the proper priority. If the problem occurs frequently, notify the Strobe system programmer. STR0300I SAMPLE DATASET sdsname CLOSED, tttttt/eeeeee SAMPLES TAKEN Explanation: The sample dataset sdsname is closed and can be used to produce a Strobe Performance Profile. sdsname is the low-order qualifier of the sample dataset name. The dataset contains tttttt total samples and eeeeee execution samples. System Action: The measurement task completes processing. User Response: None required. STR0301E sdsname SAMPLE DATASET OPEN FAILED Explanation: Strobe cannot open the sample dataset sdsname. sdsname is the low-order qualifier of the sample dataset name. You may have insufficient storage to obtain buffers for the sample dataset. Messages Produced by Strobe System Action: The measurement task terminates. User Response: Modify the REGION parameter in the JCL, and resubmit the request. STR0302E 3-5 sdsname SAMPLE DATASET OPEN FAILED FOR UPDATE Explanation: Strobe cannot open the sample dataset sdsname for update. sdsname is the loworder qualifier for the dataset name. System Action: Strobe continues execution of the target program. The Measurement Session Data report will be incomplete. User Response: STR0303W LOST Notify the Strobe system programmer. GETMAIN FAILURE FOR CSECT TABLE - SOME ATTRIBUTION INFORMATION MAY BE Explanation: A measurement task module cannot obtain additional storage. System Action: lost. Strobe continues sampling, but some control section mapping detail may be User Response: Increase the region size and resubmit the request. STR0304W ddname NOT AVAILABLE Explanation: Strobe cannot open the named target program load module library whose ddname is ddname. System Action: Strobe continues sampling normally. However, the Strobe Performance Profile produced from the measurement session will be incomplete. The Program Section Usage Summary report will show execution time data for the entire module only, not in detail for its control sections. The Program Usage by Procedure report will show only one unnamed section for the module and no procedure names. User Response: You may have omitted or incorrectly specified the required library data definition statement. Make the appropriate corrections, and resubmit the request. STR0305I UNABLE TO OBTAIN MODULE MAPPING DATA FOR modname Explanation: Strobe attempted to gather module mapping data for a load module modname, and Strobe cannot find the load module in the library or libraries specified in the load module library data definition statement (for example, STEPLIB, JOBLIB), in a link list dataset, or in the dataset named by the STRBLIB operand. System Action: Strobe continues sampling (unless the operating system could not locate the load module), but the Strobe Performance Profile will have the deficiencies described by message STR0304W.  The possible causes include: • The named module is resident in a link pack area and LPALIB searches were disabled at installation. • You incorrectly named a library in the STRBLIB operand in the ADD operation. • The library or libraries do not contain the named module. User Response: STR0306W None required. LIBRARY ALLOCATION FAILED - RC=rc; ERC/IRC= erc/irc; dsname Explanation: Strobe encountered a non-zero return code while attempting to allocate a load library, dsname, to search for control section data. The return code is rc, error reason code is erc, and the information reason code is irc. System Action: Strobe cannot collect control section data from this load library. User Response: Ensure that you have correctly specified the library name. If the name is correct, notify the Strobe system programmer. STR0307W DISCARDED MODULE modname MAPPED SIZE UNEQUAL TO IDENTIFIED SIZE, CSECT DATA Explanation: The version of module modname referenced for mapping was different from the version executing in the job. 3-6 Strobe Messages Guide System Action: Strobe deletes the erroneous mapping data and continues measuring. Strobe will produce a Performance Profile but some attribution data in the Profile may be incomplete. User Response: Either remove the incorrect version from the library search path, or use the STRBLIB option to put the correct version at the top of the search path. STR0308W TOO MANY LOAD LIBRARIES SPECIFIED - ONLY 16 USED Explanation: You specified more than 16 load libraries on the STRBLIB operand. System Action: Strobe uses only the first 16 load libraries specified. User Response: None required. STR0309W TWO OR MORE ATTACHES IN AN INTERVAL - TASKLIB MAY BE LOST Explanation: The TASKLIB pointers for ATTACHES became overlaid because either the user program issued ATTACHES rapidly or Strobe used a very long sampling interval. Because Strobe only has storage to record one TASKLIB pointer for an ATTACH during a sampling interval, if multiple ATTACHES occur the latest will overlay the previous one. If an ATTACH that was overlaid specified a unique TASKLIB, reference to it will be lost. In this case some module mapping information may be missing. System Action: Strobe continues processing, but some module mapping information may be missing. User Response: If significant module mapping data is lost, resubmit the measurement with a shorter sampling interval. If this is not successful, you can force the identification of the missing TASKLIB by resubmitting the measurement request and specifying TASKLIB as a STRBLIB parameter. STR0310W MODULE modname HAS SCATTER ATTRIBUTE Explanation: A load module has the scatter attribute. System Action: Strobe continues sampling normally. However, the Strobe Performance Profile produced from the measurement session will be incomplete. The Program Section Usage Summary report will show execution time data for the entire module only, not in detail for its control sections. The Program Usage by Procedure report will show only one unnamed section for the module and no procedure names. User Response: Research whether you can relink the module without the scatter attribute. If you can, then remeasure afterwards. STR0311W JSTCB JLB POINTS TO INVALID DCB Explanation: A STEPLIB, JOBLIB, or TASKLIB DCB was found in other than a valid OPEN status. A sampling interval coincided with task termination. System Action: may be lost. The measurement task completes processing, although some module data User Response: Resubmit the measurement request. If you are measuring a batch job, increase the sample rate and resubmit the request. STR0312E ADDRESS SPACE NOT AUTHORIZED TO CREATE SAMPLE DATASET Explanation: This message is followed by message STR6800I. The security subsystem was queried for the authorization level for this name. The level returned would not permit creation of a sample dataset with this name. System Action: The measurement task terminates. User Response: Either change the Strobe parameters defining how the sample dataset name is generated to adhere to installation conventions, or modify security subsystem rules to allow authorization for the newly defined Strobe convention. STR0313W ADDRESS SPACE NOT AUTHORIZED TO READ LIBRARY Explanation: This message is followed by message STR6800I. The security subsystem was queried for the authorization level for this name. The level returned would not permit reading of a load module library with this name. The library is removed from the module mapping library search list. Messages Produced by Strobe 3-7 System Action: some modules. Strobe continues sampling, but module mapping data may be missing for User Response: Modify security subsystem rules to authorize read access to the library. STR0314W DATASPACE ALLOCATION FAILURE-- LONGNAMES WILL NOT BE REPORTED Explanation: An error occurred during the allocation of the long names dataspace. System Action: Strobe continues measuring without measuring modules with names exceeding eight characters. User Response: STR0320E Notify the Strobe system programer. OPEN/CLOSE TIME EXCEEDED Explanation: The Strobe sample dataset open or close processing did not complete within the expected CPU time. System Action: The measurement task stops sampling and terminates with a user ABEND code of 322. The Measurement Session Data report will be incomplete. User Response: STR0321W Notify the Strobe system programmer. Longname dataspace flush failed - DASP(xx), RC(xx), RSN(xx) Explanation: dataspace. An error occurred during end-of-measurement processing of the long names System Action: Strobe continues end-of-measurement processing; however, names exceeding eight characters may not be reported correctly. User Response: STR0330E Notify the Strobe system programer. message Explanation: The CA-Panexec interface had difficulty processing a Strobe request. The message displayed is returned by the CA-Panexec interface program. System Action: some modules. Strobe continues sampling, but module mapping data may be missing for User Response: Notify the Strobe system programmer. STR0331I PID found nnnnnnnn sample xxxxxxxx Explanation: Strobe identified that it is running in an OMVS address space and has collected the PID (Process ID) nnnnnnnn on sample number xxxxxxxx. System Action: Strobe continues. User Response: No response necessary. Message is for diagnostics only. STR0332I dynaTrace agent found aaaaaaaaaaaaaaaaa Explanation: Strobe identified that dynaTrace agent aaa...aaa is active in the address space. System Action: Strobe continues by connecting to dynaTrace and starting a session. User Response: No response necessary. Message is for diagnostics only. STR0340W PANXACCS INTERFACE MODULE NOT AVAILABLE Explanation: Strobe for AllFusion CA-Panexec is installed but Strobe cannot find the interface module named PANXACCS, which is supplied by the CA-Panexec vendor. This message is accompanied by a system 806-4 ABEND message, but Strobe does not terminate abnormally. System Action: some modules. Strobe continues sampling, but module mapping data may be missing for User Response: Notify the Strobe system programmer. STR0341W SUPPORT PANXACCS INTERFACE ERROR-- SAVE LOG AND SAMPLE FILE-- CONTACT CUSTOMER Explanation: Strobe encountered an error in the Strobe CA-Panexec interface. 3-8 Strobe Messages Guide System Action: Strobe logs the problem in the sample dataset, corrects the error, and continues sampling. User Response: Save a copy of the sample dataset and the Strobe log, and contact Compuware Customer Support. STR0342W BINDER MESSAGE: text Explanation: System Action: Strobe displays text, the Binder API error message. Strobe continues sampling, but module mapping may be incomplete. User Response: Refer to IBM’s MVS System Messages manual for information on the message issued by the binder. STR0343C FROM BINDER API: FUNCTION=fnct RC=rc RSN=rsnc Explanation: The binder experienced a failure. The binder function that failed is fnct, the return code is rc, and the reason code from the binder is rsnc. System Action: Strobe continues sampling, but module mapping may be incomplete. User Response: Notify the Strobe system programmer. Refer to IBM’s DFSMS/MVS Program Management manual for the binder API return codes and reason codes. STR0344C ACTIVE DEVICE TABLE CORRUPTED Explanation: System Action: Strobe detected an error in the Active Device Table. Strobe will not report DASD model type, VTOC location, and cache status. User Response: Save a copy of the sample dataset and the Strobe log, and then contact Compuware Customer Support. STR0345W REPORTED GETMAIN FAILED FOR THE CACHE I/O AREA - CACHE STATUS WILL NOT BE Explanation: Strobe cannot obtain enough virtual storage in ESQA (subpool 245). System Action: Strobe continues sampling, but will not report cache status on the Data Set Characteristics Supplement. User Response: STR0346W Notify the Strobe system programmer. FREEMAIN FAILED FOR THE CACHE I/O AREA, STORAGE ADDRESS addr Explanation: The FREEMAIN failed for the cache I/O area in ESQA (subpool 245), beginning at address addr. System Action: The measurement task terminates. User Response: Save a copy of the sample dataset and the Strobe log. Notify the Strobe system programmer. STR0347W FREEMAIN FAILED FOR AN ACTIVE UCB TABLE SEGMENT, STORAGE ADDRESS addr Explanation: address addr. System Action: The FREEMAIN failed for a segment of the Active UCB table, beginning at The measurement task terminates. User Response: Save a copy of the sample dataset and the Strobe log, and then contact Compuware Customer Support. STR0348W DEVICE NUMBER MISMATCH FOR DEVICE nnnn Explanation: During measurement, an I/O configuration change caused a UCB address to be reassigned to another device. System Action: device nnnn. Strobe will not report DASD model type, VTOC location, or cache status for User Response: programmer. Save a copy of the sample dataset and Strobe log. Notify the Strobe system Messages Produced by Strobe STR0349W 3-9 I/O ERROR CODE ec OBTAINING CACHE STATUS FOR DEVICE nnnn Explanation: Strobe encountered an I/O error with error code ec while attempting to obtain cache status for device nnnn. System Action: Strobe will not report cache status for the device. User Response: Save a copy of the sample dataset and the Strobe log. Notify the Strobe system programmer. STR0350E GETMAIN FAILED FOR STRVPH3 WORKAREA Explanation: initialization. A critical measurement task failed to obtain sufficient storage for its System Action: The measurement task terminates. User Response: Increase the region size and resubmit the request. STR0351E RECURSIVE ENTRY TO STRVPH3 INIT Explanation: A fatal control error occurred in a measurement task module. System Action: The measurement task terminates. User Response: Notify the Strobe system programmer. STR0354W STROBE DETECTS EXECUTION WITHIN GOFF MODULE module CONTAINING LONG NAME SECTIONS Explanation: Strobe encountered a Generalized Object File Format (GOFF) module that contains sections with long names. System Action: For GOFF modules with section names that are greater than 8 characters in length, Strobe reports execution information under the pseudo-section name #LONGnnn, where nnn is a sequence number that Strobe resets to 1 within each new module.  Strobe may report information under the #LONGnnn pseudo-section on any of the following Strobe Performance Profile reports: the Program Usage by Procedure, the Wait Time by Module, the Most Intensively Executed Procedures, the Most Extensive Inactive Storage Areas, the Program Section Usage Summary, the Program Usage by Procedure, the Transaction Usage by Control Section, the Attribution of CPU Wait Time, and the Attribution of CPU Execution Time. User Response: None required. To identify the names of the GOFF module sections reported under the pseudo-section #LONGnnn, note the offsets that Strobe reports and use a linkage editor map of the module to determine the section name. STR0355W STROBE ENCOUNTERED RTLS MODULE(S) Explanation: Strobe encountered a language attribution module loaded by Run Time Library Services (RTLS). System Action: Strobe continues sampling; however, attribution data for that module may be missing or incorrect. User Response: Specify the Run Time Language Library on a STROBLIB parameter and rerun the measurement session. Although Strobe will still issue this message, once the Run Time Language Library is specified on a STROBLIB parameter, the attribution data reported will be correct. STR0356W THRESHOLDS DISABLED - MORE THAN 12 SAMPLING INTERVALS ENCOUNTERED Explanation: Strobe has been sampling for more than 12 sampling intervals, actively sampling for more than 34 hours. System Action: Strobe continues processing, but all thresholds are disabled. User Response: Reduce sampling time and resubmit the request. STR0358I MODULE CALLABLE SERVICE service FAILED, RC=rc, RSNC=rsnc Explanation: The UNIX System Services Callable Service service did not return a full path name. rc is the return code. rsnc is the reason code. 3-10 Strobe Messages Guide System Action: Strobe continues processing with a partial path name. The Data Set Characteristics and Data Set Characteristics Supplement reports will show a partial path name for this file. User Response: None required. STR0359W SMF RECORDING FOR TYPE 92 RECORDS IS NOT ACTIVE, NO USS FILE SYSTEM I/O COUNTS WILL BE REPORTED Explanation: Strobe does not report I/O counts for OS/390 UNIX System Services Hierarchical File System (HFS) or z/FS files because the SMF recording for Type 92 records is not active. System Action: report. HFS and z/FS I/O counts are not reported on the Data Set Characteristics User Response: To report I/O counts for HFS or z/FS files, modify a user-exit module in the Strobe control dataset. See Appendix A of the Strobe Installation and Customization Guide for an example of a user-exit module. STR0360W STRBXDS2 CONTROL BLOCK xxx INVALID - NO MATCH ON EYECATCHER Explanation: Validation of control block xxx failed. System Action: The data required to build the z/OS Memory Objects report will not be collected and the report will not be produced. Measurement continues. User Response: STR0401W None required. GETMAIN FAILURE - I/O INFORMATION WILL NOT BE REPORTED Explanation: A measurement task module cannot obtain sufficient storage for its work area. System Action: Strobe continues sampling, but there are no I/O reports in the Performance Profile; or if produced, the reports contain minimal information. User Response: STR0402W Increase the region size and resubmit the request. GETMAIN FAILURE - SOME DATA SETS MAY NOT BE MAPPED Explanation: Strobe cannot obtain enough virtual storage for an internal table. System Action: Strobe continues sampling, but the I/O reports in the Strobe Performance Profile do not contain information about datasets residing on some units. User Response: STR0403W Increase the region size and resubmit the request. GETMAIN FAILURE - DATA SET CHARACTERISTICS MAY BE MISSING Explanation: dataset table. Strobe cannot obtain enough virtual storage for an extension to its internal System Action: Strobe continues sampling but may not collect dataset characteristics for some datasets active during the measurement session. User Response: STR0404E Increase the region size and resubmit the request. STRBVIO FAILURE - DATA SET CHARACTERISTICS MAY BE MISSING Explanation: A measurement task module has encountered a fatal error. System Action: Strobe continues sampling but stops taking I/O samples. User Response: Notify the Strobe system programmer. STR0405W GETMAIN FAILURE - LSR STATISTICS WILL BE MISSING OR INCOMPLETE Explanation: The measurement task module STRBLSRS cannot obtain sufficient storage for its work area or its internal tables. System Action: Strobe disabled STRBLSRS. Strobe continues sampling but no longer collects LSR statistical information during this measurement session. User Response: STR0406W The next time you submit this request, increase the region size. STRBLSRS DISABLED, EXCEEDED MAX GETMAINS Explanation: An internal error occurred in the measurement task module STRBLSRS. Messages Produced by Strobe 3-11 System Action: Strobe disabled STRBLSRS. Sampling continues, but Strobe will no longer collect LSR statistical information during this measurement session. User Response: STR0407W Notify the Strobe system programmer. STRBLSRS DISABLED, INTERNAL ERROR error Explanation: An internal error occurred in the measurement task module STRBLSRS; error is an internal code. System Action: Strobe disables STRBLSRS. Sampling continues, but Strobe no longer collects LSR statistical information during this measurement session. User Response: STR0408W Notify the Strobe system programmer. GETMAIN FAILURE FOR THE ACTIVE DEVICE TABLE Explanation: Strobe cannot obtain enough virtual storage for an internal table. System Action: Strobe continues sampling, but does not report DASD model type, VTOC location, and cache status. User Response: STR0409W Increase the region size and resubmit the request. LOAD FAILED FOR MODULE module ABEND CODE=Sxxx-xx Explanation: Strobe invoked an MVS service to load a module, but the load request failed. Sxxx-xx is the abend and reason code associated with the failed load. System Action: Strobe continues processing, but there may be some loss of function. User Response: Notify the Strobe system programmer. STR0410E module FAILURE text Explanation: A Strobe module encountered an error. The message text names the Strobe module and provides information about the failure. System Action: Strobe continues processing, but there may be some loss of function. User Response: Notify the Strobe system programmer. STR0411W STORAGE-OBTAIN FAILURE IN module FOR reason Explanation: A Strobe module invoked a MVS routine to obtain storage, but the storage request failed. The message text names the Strobe module and indicates the reason for the storage request. System Action: Strobe continues processing, but there may be some loss of function. User Response: Notify the Strobe system programmer. STR0412E MODULE FUNCTION FAILED RC xxxx RSNC xxxxx Explanation: Strobe unsuccessfully invoked an MVS function. The message text names the Strobe module and the function that was invoked. RC xxxx is the return code and RSNC xxxx is the reason code returned by the function. System Action: Strobe continues processing, but there may be some loss of function. User Response: Notify the Strobe system programmer. STR0413W MODULE FUNCTION FAILED, RC=rc Explanation: The specified function failed with the return code of rc. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. STR0414W STORAGE OBTAIN FAILED FOR storarea Explanation: A STORAGE OBTAIN for the area specified by storarea failed. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. 3-12 Strobe Messages Guide STR0415W BatchPipes query failed RC xxxx RSNC xxxxx Explanation: Strobe unsuccessfully invoked an MVS function to query BatchPipes. RC xxxx is the return code and RSNC xxxx is the reason code returned from the query. Strobe does not support third-party implementations of BatchPipes. System Action: Strobe continues processing, but BatchPipes statistics will not be provided. User Response: Notify the Strobe system programmer if using IBM's BatchPipes. STR0501E I/O ERROR DURING UPDATE OF SAMPLE DATA SET Explanation: Strobe encountered a permanent I/O error while updating the first record in a sample dataset. This message follows message STR0507W, which contains the standard SYNAD messages returned by the operating system. System Action: Strobe continues execution of the target program but collects no further samples. The Measurement Session Data report is incomplete. User Response: error. STR0502W Notify the Strobe system programmer. There has probably been a hardware I/O ERROR READING LOAD LIBRARY Explanation: Strobe encountered an I/O error while accessing a module from a load module library. This message follows message STR0507W, which contains the standard SYNAD messages returned by the operating system. The SYNAD messages identify the partitioned dataset causing the error. System Action: Strobe continues sampling (unless the operating system has been unable to locate the load module), but the Strobe Performance Profile produced from the measurement session is incomplete.  The Program Section Usage Summary report shows execution time data for the entire module only, not in detail for its control sections, and the Program Usage by Procedure report shows only one unnamed section for the module and no procedure names. User Response: error. STR0503E Notify the Strobe system programmer. There has probably been a hardware OUT OF SPACE ON SAMPLE DATA SET Explanation: No more space is available in the sample dataset. The message precedes message STR0505E, which displays the ABEND and return codes. Your target sample size may be too high. Generally, a target size of 8000 to 32000 is adequate. If you want to retain the sample size, you need a larger sample dataset. System Action: Strobe continues execution of the target program, but collects no further samples. The Measurement Session Data report is incomplete. In addition, reports will not include module mapping data. User Response: You can allocate a larger sample dataset before the measurement session begins. The name of the sample dataset must correspond to the name that Strobe creates. See the Strobe User Guide for additional information. STR0504E I/O ERROR WRITING TO SAMPLE DATA SET Explanation: Strobe encountered a permanent I/O error while writing to a sample dataset. This message follows message STR0507W, which contains the standard SYNAD messages returned by the operating system. System Action: samples. Strobe continues execution of the target program but collects no further User Response: error. Notify the Strobe system programmer. There has probably been a hardware STR0505E ABEND WHILE PROCESSING SAMPLE DATA SET - COMPLETION CODE=abendcode, RETURN CODE=rc Explanation: Strobe encountered an ABEND while opening, writing to, or closing a sample dataset. The ABEND code is abendcode, and the return code is rc. Messages Produced by Strobe 3-13 System Action: Strobe continues execution of the target program but collects no further samples. Strobe may produce a Performance Profile, but some reports will be incomplete. User Response: STR0506E Notify the Strobe system programmer. WRITE ATTEMPTED TO CLOSED SAMPLE FILE Explanation: The measurement task attempted to write to a closed sample dataset. System Action: The measurement task terminates. User Response: Notify the Strobe system programmer. STR0507W I/O ERROR synad messages Explanation: Strobe encountered a permanent I/O error. This message contains the standard SYNAD messages synad returned by the operating system, and it is followed by messages messages describing the I/O error. System Action: The measurement task terminates. User Response: Notify the Strobe system programmer. STR0508W CODE=rc ABEND WHILE READING LOAD LIBRARY - COMPLETE CODE= abendcode, RETURN Explanation: Strobe encountered an ABEND while opening, reading, or closing a load library dataset. The ABEND code is abendcode, the return code is rc. System Action: Strobe continues sampling, but obtains no further mapping data from the failing library. Strobe will produce a Performance Profile, but some reports may be incomplete. User Response: STR0509W Notify the Strobe system programmer. DATASPACE API INITIALIZATION FAILED -- FUNCTION DISABLED, RC=rrr, ERC=erc Explanation: An error occurred during the initialization of the Dataspace Manager API. System Action: Strobe continues sampling without Dataspace Manager functions. User Response: Notify the Strobe system programmer. STR0510W DATASPACE API DEALLOCATION FAILURE; RC=rrr; ERC=erc Explanation: An error occurred during the termination of the Dataspace Manager API. System Action: Strobe continues terminating Dataspace Manager API. User Response: Notify the Strobe system programmer. STR0512E SAMPLE FILE ALLOCATION-OPEN CALL FAILED RC=xx Explanation: Strobe made a call to the MSAS address space to allocate and open a sample dataset, and the request failed. There are accompanying messages from the MSAS address space that should explain the error. Refer to the Strobe log for the additional messages. System Action: The measurement task terminates. User Response: The error may be temporary. Try resubmitting the request. STR0540W GETMAIN FAILURE IN STRBSNAP - DIAGNOSTIC SNAPPING DISABLED Explanation: A GETMAIN failure occurred when a measurement task module tried to obtain storage for a work area. System Action: Strobe continues sampling, but the measurement task cannot use the diagnostic SNAP feature. User Response: STR0550W Notify the Strobe system programmer. STRBGMIM: USER TCB NOT AVAILABLE FOR CAPTURE Explanation: Strobe could not complete an internal request to capture user data because Strobe could not find the user target task control block (TCB). System Action: Strobe continues measuring but does not capture the additional user data. 3-14 Strobe Messages Guide User Response: Resubmit the measurement request. If the problem persists, contact Compuware Customer Support. STR0551W STRBGMIM: STORAGE REQUEST FAILED FOR CB block Explanation: System Action: A Strobe internal storage request for control block block failed. Strobe continues measuring but does not capture the additional user data. User Response: Resubmit the measurement request. If the problem persists, contact Compuware Customer Support. STR0552W STRBGMIM: AITE NOT FOUND FOR fnctname REQUEST Explanation: Strobe could not locate the active table element for function fnctname requested by Strobe internal request REMOVE or FREESTOR. System Action: Strobe continues measuring but does not execute the requested function. User Response: Contact Compuware Customer Support. STR0553W STRBGMIM: CAPTURE PROCESSING FAILED DURING VECTOR SWAP Explanation: A Strobe internal request to insert a capture routine failed. System Action: Strobe continues measuring, but does not enable the capture routine. User Response: Contact Compuware Customer Support. STR0554W STRBGMIM: CAPTURE VECTOR ADDRESS IS INVALID. NOT IN PRIVATE STORAGE Explanation: Strobe made an internal request for a capture routine with an invalid address not in private storage. System Action: Strobe continues measuring, but does not enable the capture routine. User Response: Contact Compuware Customer Support. STR0555W ADDRESS STRBGMIM: CAPTURE PROCESSING FAILED. MULTIPLE CAPTURES FOR SAME Explanation: Strobe made an internal request for a capture routine with a vector address that had previously been processed. System Action: Strobe continues measuring but does not enable the capture routine. User Response: Contact Compuware Customer Support. STR0556W STRBGMIM: CAPTURE PROCESSING FAILED. CAPTURE FACILITY DISABLED Explanation: disabled. A Strobe internal request for a capture routine failed because the facility was System Action: Strobe continues measuring with the capture routine disabled. User Response: None required. STR0559I STRBGMIM: Explanation: Strobe has stored diagnostic data in . System Action: Strobe continues processing, but some measurement data may be missing. User Response: Contact Compuware Customer Support. STR0601W DATA COLLECTOR modname NOT IN PROPER FORMAT - {NOT A STROBE MODULE | HAS NO PROGRAM LIST |DOESN'T SUPPORT PROGRAM} - NOT USED Explanation: The data collector modname does not meet the requirements specified in the Strobe Interface manual. System Action: Strobe continues sampling without the data collector. User Response: Revise the data collector to meet Strobe Interface standards and resubmit the request. STR0602W DATA COLLECTOR modname NOT FOUND - OPERAND IGNORED Explanation: Strobe cannot find the data collector modname. Messages Produced by Strobe System Action: Strobe continues sampling without the data collector. User Response: Place the data collector in a link list dataset and resubmit the request. STR0603W 3-15 DATA COLLECTOR modname RETURN CODE = rc - ROUTINE DISABLED Explanation: The data collector modname returned a return code, rc, greater than or equal to 16 (severe error). System Action: Strobe continues sampling without the data collector. User Response: Notify the Strobe system programmer. STR0604W DATA COLLECTOR modname ABENDED - ROUTINE DISABLED Explanation: The data collector modname terminated abnormally. This message appears with other messages that provide detailed information about the ABEND. System Action: Strobe continues sampling without the data collector. User Response: Notify the Strobe system programmer. STR0605W GETMAIN FAILURE - SOME MODULES MAY NOT BE MAPPED Explanation: table. Strobe cannot obtain sufficient storage for an extension to its internal module System Action: Strobe continues sampling without mapping information for some modules. User Response: Increase the region size and resubmit the request. STR0606W DATA COLLECTION DRIVER STRBVDCC ABENDED - DC INTERFACE DISABLED Explanation: The Data Collection Interface Driver terminated abnormally. This message appears with other messages that provide detailed information about the ABEND. System Action: Strobe continues sampling without subsystem or attribution data. User Response: Notify the Strobe system programmer. STR0607W DATA COLLECTION INTERFACE CALLED WITH INVALID FUNCTION CODE (fctcode) Explanation: The data collection interface was called with an invalid function code fctcode. System Action: Strobe continues sampling without some subsystem or attribution data. User Response: programmer. Examine all user-written data collectors, and then notify the Strobe system STR0608W DATA COLLECTION INTERFACE CALLED WITH NO PARAMETER LIST Explanation: The data collection interface was called with no parameter list pointer. System Action: Strobe continues sampling without some subsystem or attribution data. User Response: Notify the Strobe system programmer. STR0609W DATA COLLECTION INTERFACE INVOKED BY UNKNOWN CALLER Explanation: The data collection interface was called by a program not recognized by Strobe. System Action: Strobe continues sampling without some subsystem or attribution data. User Response: Notify the Strobe system programmer. STR0610W GETMAIN FAILURE IN STRBVDCC FOR block - DC INTERFACE DISABLED CSECT csectname sampnumber. Explanation: Virtual storage is not available for the control block described by block, CSECT described by csectname, and sample number described by sampnumber. System Action: Strobe continues sampling without some subsystem or attribution data. User Response: Increase the region size so that Strobe can obtain the necessary virtual storage, and then resubmit the request. Contact the Strobe system programmer to obtain Strobe virtual storage requirements. 3-16 Strobe Messages Guide STR0611W GETMAIN REFUSED IN STRBVDCC FOR block - DC INTERFACE DISABLED CSECT csectname sampnumber. Explanation: Strobe made excessive requests for virtual storage for the control block described by block, CSECT described by csectname, and sample number described by sampnumber. System Action: Strobe continues sampling without some subsystem or attribution data. User Response: Increase the region size so that Strobe can obtain the necessary virtual storage, and then resubmit the request. Contact the Strobe system programmer to obtain Strobe virtual storage requirements. STR0612W GETMAIN FAILURE IN STRBVDCC FOR VDCCWORK AREA Explanation: System Action: Virtual storage is not available for the VDCCWORK AREA. Strobe continues sampling without any subsystem or attribution data. User Response: Increase the region size so that Strobe can obtain the necessary virtual storage, and then resubmit the request. Contact the Strobe system programmer to obtain Strobe virtual storage requirements. STR0613W DATA COLLECTOR datacollector IGNORED - STROBE INTERFACE NOT LICENSED Explanation: option. System Action: You attempted to use the Strobe Interface, but your site has not licensed this Strobe will not invoke the user-written data collector datacollector. User Response: To obtain information about licensing the Strobe Interface, contact Compuware Customer Support. STR0614E ERROR IN DATASPACE API FUNCTION xx FOR DATASPACE yy (KEY zz) Explanation: An error occurred in the dataspace manager API. xx is the function requested. yy is the name of the dataspace. zz is the key of the entry. System Action: The variable returned depends on the caller of the API. User Response: Notify the Strobe system programmer. STR0630E GETMAIN FAILURE IN modname - MODULE IDENTIFICATION DISABLED Explanation: Strobe cannot obtain virtual storage for an extension to its internal module table in module modname. System Action: Strobe continues sampling without default module identification information. If the module was identified by a data collector, the Performance Profile contains module mapping information for that module. Otherwise, Strobe attributes module activity to a pseudo-section, resulting in excessive values for all pseudo-sections. User Response: STR0631W Increase the region size and resubmit the request. BATCHPIPE WAIT DETECTED, FILE CANNOT BE IDENTIFIED Explanation: file. Strobe identified BatchPipe wait but is unable to assign this wait to a specific System Action: Strobe continues processing but information for BatchPipes files in the Performance Profile will be incomplete User Response: Check that you have performed the procedure required to collect BatchPipes information that is detailed in the Strobe Installation and Customization Guide. If you have performed the procedure and the problem persists, contact Compuware Customer Support. STR0632E BATCHPIPE CONTROL BLOCK ERROR, block Explanation: Strobe detected BatchPipes wait, but due to an internal control block change, Strobe cannot assign wait to a specific file. Strobe identifies the control block in block. System Action: Strobe continues processing but the information for BatchPipes files in the Performance Profile will be incomplete. User Response: Contact Compuware Customer Support. Messages Produced by Strobe STR0633W 3-17 MODULEcbid CONTROL BLOCK ERROR DURING USS FILE SYSTEM PROCESSING Explanation: Strobe encountered a control block error for cbid while attempting to identify a Hierarchical File System (HFS) file or z/FS file. System Action: Strobe does not identify the HFS or z/FS file. Strobe continues processing. User Response: Contact Compuware Customer Support STR0634W MODULE nn CONTROL BLOCK ERRORS, USS FILE SYSTEM DATA COLLECTION IS SUSPENDED Explanation: Strobe encountered nn control block errors during HFS or z/FS file identification. System Action: Strobe suspends the HFS or z/FS data collection interface. User Response: Contact Compuware Customer Support. STR0701W GETMAIN FAILURE IN STRBATTR - ATTRIBUTION DATA COLLECTION DISABLED Explanation: Strobe cannot obtain virtual storage for a work area. System Action: Strobe continues sampling without attribution data. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system STR0702W ATTRIBUTOR modname NOT FOUND - UNABLE TO COLLECT REQUESTED ATTRIBUTION DATA Explanation: Strobe cannot find the requested attributor modname. System Action: Strobe continues sampling without some attribution data. User Response: Notify the Strobe system programmer. STR0703W ATTRIBUTOR modname RETURN CODE = rc - ROUTINE DISABLED Explanation: The attributor modname returned a return code, rc, greater than or equal to 16 (severe error). System Action: Strobe continues sampling without the attributor. User Response: Notify the Strobe system programmer. STR0704W ATTRIBUTOR modname ABENDED - ROUTINE DISABLED Explanation: The attributor name modname terminated abnormally. System Action: Strobe continues sampling without the attributor. User Response: Notify the Strobe system programmer. STR0705W ATTRIBUTION DRIVER STRBATTR ABENDED - ATTRIBUTION DISABLED Explanation: The attribution driver terminated abnormally. System Action: Strobe continues sampling without attribution data. User Response: Notify the Strobe system programmer. STR0707I STRBXDS1 - CALLABLE SERVICE IXLMG FAILED, RC = rc, RSNC = rsnc Explanation: The coupling facility service, IXLMG, failed. This service is not required for Strobe measurement. Strobe writes the message to the Strobe log. System Action: Strobe continues processing, but may not collect the coupling facility service information. User Response: None required. STR0708I STROBE MEASUREMENT SERVICES release CALLED FROM STRT TSK jobname AT time, SYSTEM = system Explanation: The Measurement Services Address Space (MSAS), which includes AutoStrobe, has successfully been initialized. 3-18 Strobe Messages Guide System Action: Session manager successfully started the Measurement Services Address Space (MSAS). User Response: None required. STR0709I STROBE MEASUREMENT SERVICES release COMPLETED for STRT TSK jobname RC=nn, SYSTEM = system Explanation: The Measurement Services Address Space (MSAS) address space, which includes AutoStrobe, has terminated. System Action: The Measurement Services Address Space (MSAS) terminated due to an operator command or because of an error. User Response: None if required the return code = 0. If the return code is not zero, report the problem to the system programmer. This message can also appear on the operator’s console. STR0712I STROBE MEASUREMENT SERVICES jobname NOT STARTED - ISSUE A SESSION MANAGER MODIFY/START COMMAND Explanation: The Measurement Services Address Space (MSAS), which includes AutoStrobe, was not started and the message was sent to the operator’s console. System Action: The Measurement Services Address Space (MSAS) does not start and AutoStrobe is inoperative. User Response: Issue an MVS MODIFY for the session manager to initiate the Measurement Services Address Space (MSAS). STR0713I STROBE MEASUREMENT SERVICES release LICENSE VERIFICATION FAILED. RETURN CODE = nn REASON CODE = nnn -BASE/ASM Explanation: The Measurement Services Address Space (MSAS) was not started because a license verification error occurred when validating the license. System Action: The Measurement Services Address Space (MSAS), which includes AutoStrobe, was not initialized. User Response: STR0714E Report the problem to the Strobe system programmer. MSAS NOT INITIALIZED, MODULE VERSION CHARACTER MUST BE "v" Explanation: The version character (the fourth character of the name of the MSAS load module (STRxMSAS) is not the same of the as the version character of the load module of the session manager that attempted to create this MSAS. The session manager’s version character is specified in the message. System Action: The MSAS started task cannot be initialized and terminates. The session manager which attempted to start the MSAS started task also terminates because its associated MSAS cannot be initialized. User Response: Notify the Strobe system programmer and ensure that the names of all of the Strobe load modules for this version of Strobe have the same version character. Be sure that the PROC for the MSAS started task specifies the correct MSAS load module name. (There must be a one-to-one correspondence between the session manager and the MSAS started tasks, as determined by the version character in the fourth position of the load module names executed with the process for the two started tasks.) STR0715I console id STROBE MEASUREMENT SERVICES release STOP COMMAND RECEIVED FROM CONSOLE Explanation: The operator issued an MVS STOP command to stop the Measurement Services Address Space (MSAS). System Action: The Measurement Services Address Space (MSAS), which includes AutoStrobe, has terminated. User Response: None required. The address space can be restarted via an MVS MODIFY command to the session manager. This message can also appear on the operator’s console. STR0716W 64-BIT FORMATTED SAVE AREA ENCOUNTERED, ATTRIBUTION MAY BE INCOMPLETE Explanation: During attribution, Strobe encountered an AMODE 64-bit program using 64-bit formatted save areas. Messages Produced by Strobe System Action: Attribution for the current sample terminates. Measurement continues. User Response: None required. 3-19 Messages Returned by the Strobe Indexer Programs The Strobe Indexer programs return the following messages. STR1104W COMPILER LISTING NOT IN EXPECTED FORMAT - CONTINUING Explanation: The Indexer cannot successfully process the compiler listing dataset because it cannot find some of the listing data. System Action: The Strobe Indexer lists on SYSPRINT, the system printer output file, an edited display of the map dataset to the point of the error. It then continues by searching for another program. The Indexer produces an incomplete map dataset. Procedure names may not appear in the Strobe Performance Profile. User Response: Ensure that the compiler is supported by the Indexer in use and that the compilation options required for indexing are in effect. STR1105W CSECT LENGTH NOT FOUND Explanation: The CA Gen Indexer cannot calculate the length of the load module. System Action: The CA Gen Indexer will continue processing, but the map dataset created is not valid. User Response: Ensure that the compiler source listing used as input to the Indexer is for an application generated by CA Gen. If it is, notify the Strobe system programmer. STR1107W UNKNOWN RECORD TYPE FOUND IN MAP FILE Explanation: map dataset. The CA Gen Indexer encountered an unknown record type while creating the System Action: The CA Gen Indexer will continue processing, but the map dataset produced for this source listing is not valid. User Response: STR1108E Contact Compuware Customer Support. COMPILER LISTING NOT IN EXPECTED FORMAT - MAP DATA SET EMPTY [text] Explanation: The Indexer cannot successfully process the compiler listing dataset because it cannot find some data that it requires, such as the program name or the procedure code listing. If this message was produced by the C Indexer, one of the following statements appears in text: • BEGINNING OF OBJECT MISSING—the C Indexer could not find the beginning of the object listing. • COMPILE UNIT BLOCK INCOMPLETE—the C Indexer could not find all the information required to complete the literal or compile unit block. • COMPILE UNIT BLOCK OR PROLOG NOT FIRST—the C Indexer did not find a compile unit block or prolog at the beginning of the dataset. • END LITERAL MISSING—the C Indexer could not find all the information needed to complete a literal record. • END OF COMMENT NOT FOUND—the C Indexer could not find the end of a comment. • END OF COMPILATION NOT FOUND—the C Indexer did not find the end of the compiled listing. • END OF OBJECT LISTING MISSING—the C Indexer could not find the end of the object listing. • EPILOG RECORD INCOMPLETE—the C Indexer could not find all the information necessary to complete the epilog record. (The epilog is compiler-generated code that follows the program and handles standard linkage.) • NAME IN PROCEDURE INCOMPLETE—the C Indexer could not find all the information needed to complete a procedure name. • PROCEDURE RECORD INCOMPLETE—the C Indexer could not find all the information needed to complete the procedure record. 3-20 Strobe Messages Guide • PROLOG RECORD INCOMPLETE—the C Indexer could not find all the information necessary to complete the prolog record. (The prolog is compiler-generated code that precedes the program and handles standard linkage.) • START OR PRIVATE DEFINITION NOT FOUND—the C Indexer could not find a start definition (SD) or private definition (PD). System Action: The Indexer produces a null map dataset. Procedure names will not appear in the Strobe Performance Profile. User Response: Ensure that the compiler is supported by the Indexer in use and that the compilation options required for indexing are in effect. STR1109W IEF MAP FILE HEADER RECORD MISMATCH Explanation: file. The CA Gen Indexer encountered an error while processing the source listing System Action: The CA Gen Indexer continues processing, but the map dataset produced for this source listing is not valid. User Response: STR1110E Contact Compuware Customer Support. GETMAIN FAILURE IN modname [RC=rc] - TERMINATING Explanation: Strobe cannot obtain enough storage for the work area for module modname. The return code, if given, is rc. System Action: The Indexer terminates and produces an empty map dataset. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system STR1111W MORE THAN 100 LISTING FILES Explanation: The CA Gen Indexer exceeded its maximum input of 100 source listing files. System Action: The CA Gen Indexer will produce valid map datasets for the first 100 source listing files and then terminate normally. User Response: Run the CA Gen Indexer with the source listing files that exceeded the maximum of 100, for which the Indexer has not yet created map datasets. STR1112S COMPILER LISTING NOT IN EXPECTED FORMAT - TERMINATING [text] Explanation: The Indexer cannot successfully process the compiler listing dataset. If the C Indexer produced this message, one of the following statements appears in text: • BEGINNING OF OBJECT MISSING—the C Indexer could not find the beginning of the object listing. • COMPILE UNIT BLOCK OR PROLOG NOT FIRST—the C Indexer did not find a compile unit block or prolog at the beginning of the dataset. • END LITERAL MISSING—the C Indexer could not find all the information needed to complete a literal record. • END OF COMMENT NOT FOUND—the C Indexer did not find the end of a comment. • END OF COMPILATION NOT FOUND—the C Indexer did not find the end of the compiled listing. • END OF OBJECT LISTING MISSING—the C Indexer could not find the end of the object listing. • EPILOG RECORD INCOMPLETE—the C Indexer could not find all the information necessary to complete the epilog record. (The epilog is compiler-generated code that follows the program and handles standard linkage.) • ERROR WHILE PROCESSING NAME IN PROCEDURE—the C Indexer encountered an endof-program statement while processing detail records. • LITERAL OR COMPILE UNIT BLOCK INCOMPLETE—the C Indexer could not find all the information required to complete the literal or compile unit block. • NAME IN PROCEDURE INCOMPLETE—the C Indexer could not find all the information needed to complete a procedure name. • PROCEDURE RECORD INCOMPLETE—the C Indexer could not find all the information needed to complete the procedure record. • SOURCE STATEMENT LINE NOT FOUND—the C Indexer did not find a source statement following the prolog. (The prolog is compiler-generated code that precedes the program and handles standard linkage.) Messages Produced by Strobe 3-21 • START OR PRIVATE DEFINITION NOT FOUND—the C Indexer could not find a start definition (SD) or private definition (PD). System Action: The Indexer lists on SYSPRINT an edited display of the map dataset to the point of error and terminates. The map dataset will affect the Strobe Performance Profile in an unpredictable manner. User Response: Ensure that the compiler is one supported by the Indexer in use and that the compilation options for indexing are in effect. STR1113S LISTING} {OPEN|CLOSE} ERROR ON {DDNAME ddname|STRMAP|SYSPRINT| Explanation: The Indexer encountered an I/O error on DDNAME ddname, the map dataset STRMAP, the output report dataset SYSPRINT, or the input dataset LISTING. System Action: If the error is for the map dataset or STRMAP, the Indexer terminates and does not produce a map dataset. Otherwise, the Indexer produces an empty map dataset. User Response: Verify the data definition statement or the dataset name. If it is correct, notify the Strobe system programmer. STR1114W IEF LISTING NOT IN EXPECTED FORMAT RC=rc Explanation: The CA Gen Indexer detected an error in one of the source listing files. The return code, rc, can have the following values indicating that the Indexer failed to locate: • • • • • 4 - the literal PROGRAM-ID 8 - the literal TEXAS INSTRUMENTS INC or STERLING SOFTWARE 12 - the literal NAME 16 - the start of the CA Gen source 20 - any executable CA Gen source System Action: The CA Gen Indexer will continue processing, but the map dataset produced for this source listing will not be valid. User Response: Ensure that the compiler source listing used as input to the Indexer is for an application generated by CA Gen. If it is, notify the Strobe system programmer. STR1115E lang LISTING DATA SET IS EMPTY - TERMINATING Explanation: System Action: The LISTING dataset for the language named in lang is empty. The Indexer terminates and produces an empty map dataset. User Response: Ensure that the dataset specified on the input LISTING data definition statement is a valid dataset. If it is, notify the Strobe system programmer. STR1116S lang LISTING NOT IN EXPECTED FORMAT [RC=rc] - TERMINATING Explanation: The Indexer cannot successfully process the listing for the language named in lang because it is in an unexpected format. The return code, if given, is rc. System Action: The Strobe Indexer terminates. The Indexer lists on SYSPRINT an edited display of the map dataset to the point of the error. The Strobe Performance Profile will display incomplete indexing information. User Response: Ensure that the dataset specified on the input LISTING data definition statement is a valid dataset. If it is, notify the Strobe system programmer. STR1117S SYNAD ERROR, STRXIO text Explanation: While concatenating map datasets, the Indexer encountered one with different characteristics. System Action: The Indexer terminates. The Indexer lists on SYSPRINT an edited display of the map dataset to the point of the error. The Strobe Performance Profile will contain incomplete indexing information. User Response: of dataset. STR1118S Index the programs again, specifying a separate indexing step for each type INVALID FUNCTION PASSED TO STRXIO Explanation: The C Indexer encountered an invalid function. 3-22 Strobe Messages Guide System Action: The C Indexer terminates and may produce an incomplete map dataset. The resulting Performance Profile may not contain procedure names. User Response: STR1119S Contact Compuware Customer Support. RECFM NOT SUPPORTED BY INDEXER--LISTING Explanation: The Indexer encountered a listing dataset whose record format is not FBA, FBM, VBA, or VBM. System Action: The Indexer terminates. The Indexer lists on SYSPRINT an edited display of the map dataset to the point of the error. The Strobe Performance Profile displays incomplete indexing information. User Response: Recompile the programs using a SYSPRINT dataset formatted as FBA, FBM, VBA, VBM, and resubmit the indexing request. STR1120E DSORG PO WITHOUT MEMBER NAME NOT VALID FOR LISTING [(+nnnn)] Explanation: The listing dataset specified is partitioned, but you did not include a member name in the request. If specified, (+nnnn) indicates the relative number of the dataset in the error within the LISTING concatenation. System Action: The Indexer terminates and does not produce a map dataset. User Response: Resubmit the indexing request, and specify the member name. STR1121W INDEXER SYSPRINT DCB INCORRECT-CONTINUING Explanation: System Action: The SYSPRINT file from the compiler has incorrect DCB parameters. The Indexer terminates and does not produce a map dataset. User Response: Refer to the Strobe User Guide for the correct parameters based on language type. Enter the proper parameters and resubmit the request. STR1125E {MAP | LISTING} DATA SET NOT SPECIFIED Explanation: statement. The Indexer JOB STEP did not specify the STRMAP DD or LISTING DD System Action: The Indexer terminates and does not produce a map dataset. User Response: Specify the missing data definition statement and resubmit the request. STR1126E LISTING DATA SET MUST BE PARTITIONED OR PHYSICAL SEQUENTIAL [(+nnnn)] Explanation: The listing dataset specified to the Strobe Indexer has a dataset organization other than partitioned or physical sequential. If specified, (+nnnn) indicates the relative number of the dataset in error within the concatenation. System Action: The Indexer terminates and does not produce a map dataset. User Response: Specify a listing dataset that is either a member of a partitioned dataset or a sequential dataset, and resubmit the request. STR1127E DSORG PO WITHOUT MEMBER NAME NOT VALID FOR MAP Explanation: request. The map dataset was partitioned, but no member name was included in the System Action: The Indexer terminates and does not produce a map dataset. User Response: Resubmit the indexing request and specify the member name. STR1128E MAP FILE CANNOT SPECIFY A CONCATENATION Explanation: The STRMAP DD statement, which points to the map datasets, specifies a concatenation of datasets. System Action: The Indexer terminates and does not produce a map dataset. User Response: statement. Resubmit the request and specify a single map dataset in the STRMAP DD Messages Produced by Strobe STR1129E 3-23 MEMBER NAME INVALID WITH SEQUENTIAL DATA SET ddname [(+nnnn)] Explanation: The dataset with ddname ddname had a physical sequential organization but was specified with a member name. If present, (+nnnn) indicates the relative number of the dataset in error within the concatenation. System Action: The Indexer terminates and does not produce a map dataset. User Response: Specify either the name of a physical sequential dataset, or a partitioned organization dataset with a member name. STR1130I RDJFCB MACRO RETURN CODE = rc REASON CODE = rsncode FOR {LISTING | MAP} Explanation: Strobe encountered an internal error in the Indexer when attempting to verify the listing or map dataset. The RDJFCB macro returned a code of rc for ddname ddname. RDJFCB in the ARL (Allocation Retrieval List) field ARLCODE returned a reason code of rsncode. System Action: The Indexer does not perform any further dataset verification. It will, however, attempt to index the LISTING datasets. User Response: STR1131I Notify the Strobe system programmer. OBTAIN MACRO RETURN CODE = rc FOR {LISTING | MAP} [(+nnnn)] Explanation: Strobe encountered an internal error in the Indexer when attempting to verify the listing or map dataset. The OBTAIN macro returned a code of rc. If specified, (+ nnnn) indicates the relative number of the dataset within the concatenation. System Action: The Indexer does not perform any further dataset verification. It will, however, attempt to index the listing datasets. User Response: STR1132E Notify the Strobe system programmer. {LISTING | MAP} NOT FOUND ON VOLUME volume [(ddname +nnnn)] Explanation: A map or listing dataset was not found on volume volume. If the ddname is concatenated, (ddname +nnnn) indicates the ddname and the dataset’s relative position in the concatenation. System Action: The Indexer terminates. User Response: Ensure that the specified dataset name is correct. If the name is correct, and the dataset is cataloged, it may have been deleted from the volume in which it existed. If it is uncataloged, the volume specified may be incorrect. STR1133E MAP DATA SET MUST BE PARTITIONED OR PHYSICAL SEQUENTIAL Explanation: The map dataset name specified for the STRMAP DD statement has a dataset organization other than physical sequential or partitioned. System Action: The Indexer terminates and does not produce a map dataset. User Response: Specify a listing dataset that is a physical sequential dataset or a member of a partitioned dataset, and resubmit the request. STR1200E STRXNAT - INTERNAL ERROR Explanation: The Strobe Natural Indexer has encountered an unknown condition. System Action: The Strobe Natural Indexer terminates and may not produce a map dataset, or may produce an empty map dataset. User Response: STR1201E Notify the Strobe system programmer. STRXNAT - ERROR OPENING {LISTING|MAP} DATA SET Explanation: The Strobe Natural Indexer was unable to open the input listing dataset (the LISTING DD statement), or the output map dataset (the STRMAP DD statement). System Action: The Strobe Natural Indexer terminates and does not produce a map dataset. User Response: Verify the data definition statement or the dataset name. If it is correct, notify the Strobe system programmer. 3-24 Strobe Messages Guide STR1202E STRXNAT - COULDN'T FIND {DIRECTORY RECORD|SOURCE CODE} IN LISTING Explanation: The Strobe Natural Indexer has encountered one of three possible conditions. The input listing dataset (the LISTING DD statement) that was produced by Natural and input to the Strobe Natural Indexer was: 1. Empty 2. Incorrectly produced 3. Produced by a version of Natural that the Strobe Natural Indexer does not support at the current maintenance level. System Action: The Strobe Natural Indexer terminates and may not produce a map dataset. User Response: For conditions 1 and 2, refer to the Strobe for Adabas/Natural option manual for information on procedures available to produce Natural program listings suitable for input to the Strobe Natural Indexer. For condition 3, notify the Strobe system programmer. STR1203E STRXNAT - SOURCE LISTING INCOMPLETE Explanation: The input listing dataset (the LISTING DD statement) has reached an end-offile condition prior to returning to the main Natural program from a nested (included) program. One (but not the only) possible cause of this is an out-of-space condition that was received while producing the listing dataset (the CMPRINT DD statement in the UNLOAD step of either the STROXN or STROXNAT procedures). System Action: The Strobe Natural Indexer terminates and may produce an incomplete map dataset. The Strobe Performance Profile will display incomplete indexing information. User Response: Verify that the input listing dataset contains the Natural end-of-listing indicator (***** End of List *****) in either the last or next-to-last line of the dataset. If the listing dataset does not contain this indicator, rerun the UNLOAD step. If the listing dataset does contain this indicator, notify the Strobe system programmer. STR1300E ERROR erc DETECTED BY MODULE STRXVPLI The PL/I Indexer cannot successfully process the compiler listing dataset because module STRXVPL1 encountered error code erc. System Action: incomplete. Strobe terminates indexing. If a map dataset is produced, it could be The following are the possible error codes that can be returned: – 001 Explanation: The compiler listing is not complete, the wrong compiler options were specified, the SYSPRINT output from the PL/1 compiler was not specified as the input, Strobe did not recognize the PL/1 compiler or had an internal failure. User Response: If the compiler listing is not complete, then recompile the program. If the wrong compiler options were specified, check that you are using the compiler options in the Strobe User Guide and recompile the program. If the wrong dataset was specified as input, specific the SYSPRINT dataset from the PL/1 compiler and create the map dataset again. If Strobe did not recognize the PL/1 compiler or had an internal failure, contact Compuware Customer Support. – 002 Explanation: Strobe did not find the keyword OFFSET in the header of the compiler listing. User Response: If the SYSPRINT dataset from the PL/1 compiler was not specified as the input, specify the SYSPRINT dataset and create the map dataset again. If the listing is a valid PL/1 compiler listing, contact Compuware Customer Support. – 003 Explanation: Strobe did not find the keyword LINE# in the header of the compiler listing. User Response: If the SYSPRINT dataset from the PL/1 compiler was not specified as the input, specify the SYSPRINT dataset and create the map dataset again. If the listing is a valid PL/1 compiler listing, contact Compuware Customer Support. – 004 Explanation: listing. Strobe did not find the keyword OBJECT CODE in the header of the compiler Messages Produced by Strobe 3-25 User Response: If the SYSPRINT dataset from the PL/1 compiler was not specified as the input, specify the SYSPRINT dataset create the map dataset again. If the listing is a valid PL/1 compiler listing, contact Compuware Customer Support. – 006 Explanation: Strobe did not find the keyword FILE# in the header of the compiler listing. User Response: If the SYSPRINT dataset from the PL/1 compiler was not specified as the input, specify the SYSPRINT dataset and create the map dataset again. If the listing is a valid PL/1 compiler listing, contact Compuware Customer Support. – 010 Explanation: Strobe found the keyword End of Prologue where it was not expected. User Response: Because the PL/1 compiler listing is not in the expected format, contact Compuware Customer Support. – 014 Explanation: GETMAIN failed to get the required size of the work area. User Response: Increase the region size on the JOBCARD or on the EXEC statement, and create the map dataset again. If the failure persists, contact Compuware Customer Support. – 015 Explanation: User Response: The number of entries in the internal table file used by Strobe exceeded 400. Contact Compuware Customer Support. – 016 Explanation: The number of lines of code in the PL/1 compiler listing exceeded 50,000 lines. This number does not count the lines of code from included files. User Response: Contact Compuware Customer Support. – 017 Explanation: The number of lines of code in the PL/1 compiler listing exceeded 60,000 lines. This number does count the lines of code from included files. User Response: STR1405E Contact Compuware Customer Support. GETMAIN FAILURE IN STRXDBRM - TERMINATING Explanation: Strobe cannot obtain enough storage for the work area for module STRXDBRM. System Action: The Indexer terminates and does not produce a map dataset. User Response: Increase the region size and resubmit the request. STR1408E DBRM DATA SET IS EMPTY Explanation: System Action: The member of the DBRM partitioned dataset that you specified is empty. The DB2 Indexer terminates and does not produce a map dataset. User Response: Ensure that the dataset specified on the input listing data definition statement is a valid DBRM dataset. If it is, notify the Strobe system programmer. STR1412S DBRM MEMBER NOT IN EXPECTED FORMAT - TERMINATING Explanation: The DB2 Indexer cannot successfully process the DBRM source text because one or more of the DBRMs is in an unexpected format. System Action: The DB2 Indexer terminates. If the DISPLAY MAP option was selected when the ADD request was submitted, the Indexer lists on SYSPRINT an edited display of the map dataset to the point of the error. The Strobe Performance Profile displays incomplete indexing information. User Response: Ensure that the dataset specified on the input listing data definition statement is a valid DBRM dataset. If it is, notify the Strobe system programmer. 3-26 Strobe Messages Guide STR1413S OPEN ERROR ON DDNAME {SYSPRINT|STRMAP|LISTING} Explanation: The DB2 Indexer encountered an error while attempting to open the report output dataset SYSPRINT, the map dataset STRMAP, or the input dataset listing. A data definition statement may be missing or not valid. System Action: The Indexer terminates and does not produce a map dataset. User Response: Verify the data definition statement. If it refers to a valid dataset, notify the Strobe system programmer. Messages Returned by the Strobe History Manager The Strobe History Manager returns the following messages. STR1800E SYSTEM SERVICE FAILED (sysserve) ddname - RC=rc ERC=erc Explanation: The system service sysserve for ddname ddname failed. The return code is rc, and the reason code, if given, is erc. System Action: The history manager may terminate. User Response: Notify the Strobe system programmer. STR1801E CREATE INTERNAL ERROR - HGWA ALREADY EXISTS Explanation: A duplicate call was made to build a history global work area (HGWA). System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1802E fnctname INTERNAL ERROR - HGWA DOES NOT EXIST Explanation: A function fnctname failed because Strobe could not find a history global work area (HGWA) control block. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1803E fnctname - ddname DATA SET NOT OPERATIONAL Explanation: While executing function fnctname, Strobe found the dataset that ddname ddname refers to is not operational. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1804E fnctname - ddname ENVIRONMENT NOT ESTABLISHED Explanation: Strobe attempted to use the dataset referred to by ddname ddname without first building the necessary control blocks. The function name that detected the error is fnctname. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1805E OPEN - ddname DATA SET ALREADY OPEN Explanation: Strobe attempted to open the dataset that ddname ddname refers to and found that it was already opened. System Action: The history manager terminates. User Response: Notify the Strobe system programmer. STR1806E fnctname - ddname HGWA CORRUPTION DETECTED Explanation: While processing a call for function fnctname and ddname ddname, Strobe detected history global work area (HGWA) corruption. System Action: The history manager terminates. Messages Produced by Strobe User Response: STR1807E 3-27 Contact Compuware Customer Support. fnctname - ddname DATA SET NOT OPEN Explanation: Strobe function fnctname found that the dataset that ddname ddname refers to was already closed. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1808E fnctname - ddname PLIST MISSING OR INVALID Explanation: While processing a call for function fnctname and ddname ddname, Strobe found that the parameter list was missing or invalid. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1809E fnctname - ddname QPL POINTER INVALID AT address Explanation: While processing function fnctname for ddname ddname, Strobe found that the history parameter list pointer at address addr was invalid. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1810S ddname DATA SET NOT ALLOCATED Explanation: During startup, Strobe determined that the dataset that ddname ddname refers to was missing. Strobe requires that this dataset be allocated. System Action: The history manager terminates. User Response: Ask the Strobe system programmer to correct the history manager JCL and restart the history manager. STR1811S OSER - ddname RESERVE ALREADY OUTSTANDING Explanation: Strobe attempted to issue two reserves for the same history dataset that ddname ddname refers to. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1812S fnctname - ddname RESERVE NOT ISSUED Explanation: In the function fnctname, Strobe attempted to open the dataset that ddname ddname refers to without first reserving it. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1813W OPEN - ddname VSAM OPEN STATUS RC=rc RSN=rsn Explanation: Strobe determined that the dataset that ddname ddname refers to was not properly closed and that VSAM has performed an implicit VERIFY. The VSAM return code is rc, and the VSAM reason code is rsn. System Action: Strobe continues processing normally. User Response: Notify the Strobe system programmer. STR1814E OPEN - ddname UNABLE TO INITIALIZE DATA SET RC=rc Explanation: Strobe was unable to complete the initialization of the dataset that ddname ddname refers to. The VSAM return code is rc. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. 3-28 Strobe Messages Guide STR1815E fnctname - failingfnct ddname STATUS RC=rc RSN=rsn Explanation: A function, failingfnct, failed for the dataset that ddname ddname refers to. The return code of the failed function is rc, and the reason code of the failed function is rsn. fnctname is the function currently executing. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1816E DD FIND - ddname DDNAME INVALID Explanation: The ddname referred to by ddname is invalid. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1817E DD FIND - ddname DSNAME TABLE POINTER INVALID AT addr Explanation: Strobe found that the dataset table pointer in the ddname table referred to by ddname is invalid at address addr. System Action: The history manager terminates. User Response: Contact Compuware Customer Support. STR1818E ddname - DATA SET IS FULL Explanation: The dataset identified in ddname is full. System Action: If you receive this message while producing Performance Profile reports, Strobe will produce the reports, but no history information will be added to the history database. If you receive this message while accessing Strobe/ISPF panels to add a measurement session history or cost record, the measurement session history record will not be added to the database. User Response: Notify the Strobe system programmer. As a temporary measure, you may delete unneeded measurement session history records from the history dataset. The Strobe system programmer can allocate a larger history dataset and use the IDCAMS utility to copy information from the previous history dataset to the newly created history dataset. STR1819I HISTORY DATA SET STRUCTURES REMOVED Explanation: Strobe disabled the history file processing. System Action: Strobe continues processing. User Response: None required. STR1820E STRH INTERNAL ERROR. ERROR CODE = erc Explanation: Strobe encountered an error while attempting to access the history database. The error code is given in erc. System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database through Strobe/ISPF, the history database will be disabled. User Response: STR1821E If the problem persists, contact Compuware Customer Support. DATASTORE ENVIRONMENT NOT ESTABLISHED Explanation: not available. The system resources required for the history data temporary storage area are System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database using Strobe/ISPF, the history database will be disabled. User Response: If the problem persists, contact Compuware Customer Support. Messages Produced by Strobe STR1822E 3-29 DATASTORE FUNCTION FAILED: errortext Explanation: Strobe encountered an error accessing a temporary storage area. The reason for the error is described in errortext. System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database using Strobe/ISPF, the history database will be disabled. User Response: STR1823W If the problem persists, contact Compuware Customer Support. STRHLOG NOT ALLOCATED. LOGGING DISABLED Explanation: The message log file for measurement session history collection and reporting has not been allocated. System Action: Strobe will not write messages to the history log, but all other measurement session history collection and reporting will continue normally. User Response: Allocate a log file for measurement session history collection and reporting and resubmit the request. STR1824W ERROR {OPENING | CLOSING} STRHLOG. LOGGING DISABLED Explanation: Strobe encountered an error attempting to open or close the log file for measurement session history collection and reporting. System Action: Strobe will not write messages to the history log, but all other measurement session history collection and reporting will continue normally. User Response: STR1825W Notify the Strobe system programmer. INCORRECT DCB OPTIONS FOR STRHLOG. LOGGING DISABLED Explanation: The DCB parameters for the history log file are not correct. System Action: Strobe will not write messages to the history log, but all other measurement session collection and reporting will continue normally. User Response: Review the instructions for allocating the history log file described in the Strobe Installation and Customization Guide and reallocate the dataset. STR1826W SWAREQ FAILED. RC=rc. LOGGING DISABLED Explanation: A call to an MVS service, SWAREQ, failed. Log functions will not operate. System Action: Strobe continues processing, but there will be no history log. User Response: Notify the Strobe system programmer. STR1827W fnctname FOR STRHLOG FAILED. LOGGING DISABLED Explanation: Function fnctname for log processing failed. The history log is disabled. System Action: Strobe continues processing, but there will be no history log. User Response: Notify the Strobe system programmer. STR1828W STRHLOG I/O ERROR ENCOUNTERED. SENSE BYTES: xxx STATUS BYTES yyyy. LOGGING DISABLED Explanation: An I/O error occurred while processing the history log. System Action: Strobe continues processing but will not process history log information. User Response: Notify the Strobe system programmer. STR1829E STORAGE ALLOCATION FAILED Explanation: An attempt to obtain storage allocation failed. System Action: All Strobe measurement session history collection and reporting is disabled. User Response: Notify the Strobe system programmer. 3-30 Strobe Messages Guide STR1830W ABEND IN LOG PROCESSING. LOGGING DISABLED. Explanation: Strobe experienced an ABEND processing log functions. System Action: Strobe continues processing, but there will be no history log. User Response: Notify the Strobe system programmer. STR1831E RECOVERY ENVIRONMENT COULD NOT BE ESTABLISHED. RETURN CODE rc. REASON CODE reascode Explanation: Strobe could not establish a recovery environment. System Action: All Strobe measurement session history collection and reporting is disabled. User Response: Notify the Strobe system programmer. STR1832E STROBE CANNOT WRITE TO {STRHPRNT | STRHEXPT} FILE STATUS ## Explanation: Strobe’s attempt to write to either the print file (STRHPRNT) or the export file (STRHEXPT) failed. The file status is ##. System Action: Strobe continues processing but will not print or export the measurement session history record. User Response: STR1833E Contact the Strobe system programmer. INVALID CALL TO {PRINT | EXPORT}, DATASTORE IS datastore Explanation: While processing datastore datastore, Strobe received an illegal call to either the print or export function. System Action: Strobe continues processing but the measurement session history record will not be printed or exported. User Response: STR1834E Contact the Strobe system programmer. EMPTY DATASTORE PASSED TO {EXPORT | PRINT | COMPARE} Explanation: A call was made to either the export, print, or compare function, but the datastore contained no data. System Action: Strobe continues processing, but will not export or print the measurement session history record, or compare it to the baseline value. User Response: STR1835S Contact the Strobe system programmer. ERROR - DEFAULT COST PARM MISSING/INVALID Explanation: The first parameter in the SYSIN dataset for the cost record installation program was not ‘DEFAULTCOST=(‘ System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1836S ERROR - INVALID PARM INPUT Explanation: Either the last character in the parameter field was not a right parenthesis ‘)’ or a blank record was entered in the SYSIN dataset. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1837S ERROR - INCONSISTENT INPUT DATA Explanation: A service unit parameter was combined with CPU and I/O cost parameters. When you initialize cost records, you can use either service units costs or CPU and I/O costs, but not both. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. Messages Produced by Strobe STR1838S 3-31 ERROR LOADING HISTORY MANAGER Explanation: component. The cost record installation program was unable to locate the history manager System Action: The cost record installation program terminates. User Response: Review the Strobe history manager instructions in the Strobe Installation and Customization Guide and verify that the appropriate Strobe libraries are loaded. If the problem persists, contact Compuware Customer Support. STR1839S ERROR - INVALID PRIME CPU COST ENTRY Explanation: PRIMECPU data is not in the form nnnnn.nn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1840S ERROR - INVALID PRIME IO COST ENTRY Explanation: PRIMEIO data is not in the form nnnnnn.nnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1841S ERROR - INVALID PRIME SU COST ENTRY Explanation: PRIMESU data is not in the form nnnnn.nnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1842S ERROR - INVALID/MISSING PRIME TIME START ENTRY Explanation: PRIMESTART data is missing or not in the form nnnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1843S ERROR - INVALID/MISSING PRIME TIME END ENTRY Explanation: PRIMEEND data is missing or not in the form nnnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1844S ERROR - INVALID NONPRIME CPU COST ENTRY Explanation: NONPRIMECPU data is not in the form nnnnn.nn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1845S ERROR - INVALID NONPRIME IO COST ENTRY Explanation: NONPRIMEIO data is not in the form nnnnnn.nnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1846S ERROR - INVALID NONPRIME SU COST ENTRY Explanation: NONPRIMESU data is not in the form nnnnn.nnn. System Action: The cost record installation program terminates. User Response: Correct the SYSIN dataset and rerun the program. STR1847S ERROR - INVALID PARM VALUE - parmvalue Explanation: System Action: An invalid parameter value, parmvalue, was entered in the SYSIN dataset. The cost record installation program terminates. 3-32 Strobe Messages Guide User Response: STR1848E Correct the SYSIN dataset and rerun the program. DELETE FAILED. RECORD BEING ACCESSED BY ANOTHER USER Explanation: The DELETE request failed because another user is accessing this record. System Action: Strobe does not process the request. User Response: Retry the DELETE request when the record is not being used. Messages Returned by AutoStrobe AutoStrobe returns the following messages. STR1900I INITIALIZATION OF AUTOSTROBE IN STRxMSAS IN PROCESS Explanation: Processing in the Measurement Services Address Space (MSAS) has attached the AutoStrobe control task and AutoStrobe initialization processing has started. System Action: AutoStrobe initialization continues. User Response: None required. STR1901I INITIALIZATION OF AUTOSTROBE IN STRxMSAS IS COMPLETE Explanation: Initialization of AutoStrobe is complete. Any AutoStrobe requests that existed at the time when AutoStrobe was last operational are reestablished. System Action: AutoStrobe initialization continues. User Response: None required. New AutoStrobe requests can be submitted. STR1902E AUTOSTROBE INITIALIZATION TERMINATED. text of reason Explanation: AutoStrobe initialization processing encountered an error that would cause problems in subsequent attempts to perform AutoStrobe processing. The text of reason can be: • • • • • • • • unable to obtain working storage SMF type 30 records not being collected unable to attach an AutoStrobe subtask, retcode=xx unable to add dynamic exit {STRBAUSI|STRBACTR} retcode=xx REASON=yyyy error in request processing xxx STRBAEVT did not initialize invalid AUTOSTRB file System Action: AutoStrobe initialization processing is terminated User Response: Based on the reason indicated, validate the environment in which the Strobe session manager and Measurement Services Address Space (MSAS) are running.are running. If the message is "invalid AUTOSTRB file," the AUTOSTRB parameter is pointing at the UI_STRHIST file. STR1903I {MEASUREMENT INITIATED | WARNING STATE APPLIED | FOR AUTOSTROBE REQUEST xxxx, PROGRAM program OF JOB jobname BECAUSE OF condition Explanation: AutoStrobe detected abnormal behavior in the designated job and either initiated a Strobe measurement of that program or defined a “warning” that can be displayed by the user. The abnormal behavior is described by the condition text listed in the message. This text also appears on the Measurement Session Data report. The conditions for which Strobe will initiate a measurement include: • • • • EXCESSIVE ELAPSED TIME EXCESSIVE TCB TIME ABNORMAL I/O ACTIVITY - EVENT x EXCESSIVE CPU TIME IN TRANSACTION nnnn, THRESHOLD=ssss SECONDS, ACTUALS=ssss SECONDS • EXCESSIVE RESPONSE TIME IN TRANSACTION nnnn, THRESHOLD=ssssss SECONDS, ACTUALS=ssssss SECONDS Messages Produced by Strobe 3-33 For abnormal I/O activity, the event number designates the I/O threshold event that was exceeded by the monitored program. (See the description of the AUTOIOEVENTx parameters in the Strobe User Guide.) System Action: AutoStrobe processing continues. AutoStrobe places the measured program into a “held” state which means that subsequent executions of the job with this name will not be monitored until it is released using Strobe/ISPF. User Response: If a measurement was initiated, generate a Performance Profile, analyze it and make any appropriate corrections to the program code. To enable AutoStrobe to resume monitoring of the program, enter a “release” to change its status from held to pending. If changes to a batch program invalidate basis data for the measurement, you can delete it and AutoStrobe will collect new basis data for the next ten monitorings of the batch program. STR1904I MEASUREMENT FOR AUTOSTROBE REQ xxxx PGM zzzz jOB yyyy DELETED INSUFFICIENT MEASUREMENT DURATION Explanation: A program measurement initiated by AutoStrobe was discarded because either the elapsed time accumulated after the measurement was initiated was determined to be insufficient for a valid measurement. REQ xxxx identifies the AutoStrobe request associated with this program. System Action: AutoStrobe processing continues and creates ADD QUEUED request to measure the next execution of the program. The status of the AutoStrobe measurement request for this program remains “held-ms”. User Response: None required. STR1905E AUTOSTROBE DID NOT MONITOR PROGRAM progname UNDER JOB jobname CODE={ETxx|TTxx|IOxx|TMxx} REQUEST xxxx Explanation: AutoStrobe was unable to either start or complete monitoring of a program covered by the designated AutoStrobe request. The first two characters of CODE identify the AutoStrobe condition that detected the event that caused monitoring to stop. The second two characters are a numeric code that identifies the event. System Action: AutoStrobe processing for other monitored programs continues. User Response: Report this message to Compuware Customer Support. STR1906I AUTOSTROBE DID NOT MONITOR PROGRAM progname UNDER JOB jobname reason Explanation: AutoStrobe detected the initiation of a program covered by an existing AutoStrobe request, but did not monitor it for one of the following reasons: • • • • • • MAXIMUM NUMBER OF PROGRAMS ARE CURRENTLY BEING MONITORED JOB IS NOT A BATCH JOB OR STARTED TASK ISSUER OF REQUEST NOT AUTHORIZED FOR JOB MAXIMUM NUMBER OF CICS REGIONS ARE ALREADY BEING PROCESSED REGION SPECIFIED ON AN IMMEDIATE REQUEST IS NOT EXECUTING VERIFICATION OF CICS ENVIRONMENT IN REGION FAILED System Action: AutoStrobe processing continues. User Response: If the first or fourth message reason appears, no action is required or you can increase the AUTOMAX parameter value. If the third message reason appears, check the job name specified on the request and consider resubmitting the request by someone with authorization to the job(s) designated in the request. For the sixth message reason, verify that a CICS region was submitted in the request. STR1907I STATUS OF AUTOSTROBE REQUEST xxxx CHANGED TO {MONITOR|PENDING|HELD{MS|WN| AC|US}} Explanation: The initiation or termination of the program associated with the designated request or an action by AutoStrobe or a user has caused the status of the designated request to be changed. System Action: AutoStrobe processing continues. User Response: None required. 3-34 Strobe Messages Guide STR1909E ERROR PROCESSING DATA FOR REQUEST xxxx, RETCODE=xx, REASON CODE=yyy Explanation: AutoStrobe encountered an error reading or writing data about the designated request. RETCODE designates the return code from the function that was attempting to access the data. The REASON CODE identifies the data that was being processed. System Action: AutoStrobe processing continues. Reason codes 101, 102, and 106 indicate this execution of the program associated with the request is not monitored. Reason codes 103, 104, and 105 indicate that the data associated with this monitoring cannot be saved. User Response: Report the message to Compuware Customer Support. STR1910E AUTOSTROBE REQUEST xxxx PROGRAM progname UNDER JOB jobname NOT MONITORED FOR {ELAPSED TIME | TCB TIME | I/O ACTIVITY | TRANSACTION RESPONSE TIME |TRANSACTION CPU TIME CCxx} Explanation: AutoStrobe encountered an event or error in its monitoring that has caused it to stop monitoring the program for the specified condition. This message sometimes reflects an error but is often issued for normal events such as the termination of monitoring for I/O activity when the monitored program has no basis data for I/O. CC identifies the AutoStrobe condition that detected the event that caused monitoring to be stopped. xx is a numeric code that identifies the event. System Action: AutoStrobe stops its monitoring of the designated program for the specified condition. AutoStrobe monitoring for other conditions during the program execution proceeds. User Response: STR1911E Report the message to Compuware Customer Support. THRESHOLD FOR ERROR, CODE=xxx EXCEEDED, AUTOSTROBE TERMINATED Explanation: The number of errors designated by CODE=xxx has exceeded a threshold designated by that error type. The AutoStrobe routine that detected these errors initiated the termination of AutoStrobe. The error codes are those found in messages STR1909E and STR1914E. System Action: The Measurement Services Address Space (MSAS) in which this version of AutoStrobe is running will attempt to restart AutoStrobe up to 3 times in a fifteen minute interval. User Response: Report the message to Compuware Customer Support. STR1912E AUTOSTROBE AUTOMONITOR ENDED FOR JOB PROGRAM REQUEST CODE= Explanation: AutoStrobe encountered a problem indicated by code. System Action: AutoStrobe stops monitoring programname. User Response: this message. Contact Compuware Customer Support with the information provided in STR1913I MONITORING DATA FOR AN EXECUTION OF A PROGRAM zzzzzzz OF JOB yyyyyy WAS DISCARDED - INSUFFICIENT ELAPSED TIME Explanation: AutoStrobe was collecting basis data for the designated program and its monitoring of this execution found only a small amount of elapsed time. If this minimal activity is part of the basis data, it reduces the composite values in the basis data to levels that are far lower than the norm for that program when it is performing its designated function(s). System Action: The data collected during the monitoring of the designated program is not added to that program’s basis data. AutoStrobe processing continues. User Response: None required. STR1914E AUTOSTROBE requesttype REQ xxxx VSAM ERROR, FUNC=cc, VSAM RET/REASON CODES - xxxx yyyy STR1914E AUTOSTROBE requesttype REQ xxxx VSAM ERROR, KEY= xxxxxxxxxxxxxxxx Explanation: AutoStrobe experienced an error when reading or writing a record to or from the AutoStrobe dataset for request xxxx. Request types include: • Transaction monitoring • Create Transaction Candidates Messages Produced by Strobe 3-35 • AutoMeasure • Batch monitoring FUNC=cc specifies the VSAM operation that failed. KEY identifies the record that was be accessed on the AutoStrobe dataset. VSAM RET/REASON CODES specify the VSAM return code and reason code for the failed operation. System Action: AutoStrobe marks the request as complete. Other Strobe and AutoStrobe processing continues. User Response: Save the Strobe log in which this message appears and contact Compuware Customer Support. STR1915I AUTOSTROBE {MEASUREMENT|WARNING STATUS} FOR REQ xxxx PGM ppppp Explanation: AutoStrobe detected abnormal behavior in the designated program running under the designated job and either initiated a Strobe measurement of that program or defined a “warning” that can be displayed by the user. A text description of this condition appears on the Measurement Session Data report for the measurement. The conditions for which AutoStrobe will initiate a measurement include: • EXCESSIVE ELAPSED TIME • EXCESSIVE TCB TIME • ABNORMAL I/O ACTIVITY. System Action: AutoStrobe processing continues. AutoStrobe has put the request associated with the measurement in the held-ms (measurement) or held-wn (warning) state. As a result, subsequent executions of the program (under the job and step names in the request) will not be monitored until the user releases the request via Strobe/ISPF User Response: If the measurement was initiated, generate a Performance Profile for it, analyze it, and correct the measured program. To cause AutoStrobe to resume monitoring of the program, release the measurement via Strobe/ISPF to change its status from held to pending. If changes to the measured program invalidate the basis data on which the measurement was based, you many want to delete that basis data. This action causes AutoStrobe to collect new basis data on the first 10 subsequent monitorings of the program. STR1916E AUTOSTROBE HAS BEEN TERMINATED, REASON CODE = xxx Explanation: An AutoStrobe function has detected an error that is serious enough to cause termination of this version of AutoStrobe. This message is preceded by one or more messages that describe the error(s) that cause the termination. System Action: The Measurement Services Address Space (MSAS) in which this version of AutoStrobe is running will attempt to restart AutoStrobe up to three times after the initial failure in any fifteen minute interval. User Response: Check the Strobe log for the AutoStrobe messages that precede this one. They will provide more detail about the error that forced the termination of AutoStrobe. Report this message to Compuware Customer Support. STR1919W LOAD FAILED FOR FAULT-MANAGER STUB ROUTINE, ABEND CODE=Sxxx-xx Explanation: AutoStrobe-monitoring initialization processing was unable to load Strobe’s Fault-Manager stub routine (STRBSFMX). Sxxx-xx shows the abend and reason codes that would have been presented if the invocation of the MVS LOAD service had abended. System Action: AutoStrobe-monitoring initialization continues but there will be no notification to the Fault Manager for any abnormal behavior that is subsequently detected by AutoStrobe’s monitoring. User Response: Notify the Strobe system programmer. Check the library from which this version of Strobe was loaded and ensure that it contains module STRvSFMX, where v is the version character for the instance of Strobe that issued this message. STR1920I AUTOSTROBE HAS BEEN STOPPED Explanation: worked. The operator issued the MVS MODIFY command to stop AutoStrobe and it System Action: Session manager and Measurement Services Address Space (MSAS) processing continues. AutoStrobe is inoperative. User Response: None required. 3-36 Strobe Messages Guide STR1921I AUTOSTROBE HAS BEEN STARTED Explanation: worked. The operator issued the MVS MODIFY command to start AutoStrobe and it System Action: Session manager and Measurement Services Address Space (MSAS) processing continues. AutoStrobe is operative. User Response: None required. STR1922I MODIFY msasname {STOPAUTO|STARTAUTO} COMMAND IGNORED, AUTOSTROBE IS ALREADY {STOPPED|STARTED} Explanation: The operator issued the MVS MODIFY command to start or stop AutoStrobe when it was already in the state specified in the command. System Action: Session Manager and Measurement Services Address Space (MSAS) processing continues. AutoStrobe operational status remains unchanged. User Response: STR1923I None required. MODIFY jobname text COMMAND REJECTED reason Explanation: The operator issued the MVS MODIFY command to the Measurement Services Address Space (MSAS), but the command failed. The possible reasons for failure include: • • • • • AUTOSTROBE MONITORING IS NOT ACTIVE ACTION SPECIFIED IN TEXT IS NOT SUPPORTED AUTOMEASURE UTILITY IS UPDATING THE LOAD-MODULE LIST AUTOSTROBE INSTALLATION PARAMETER NOT SPECIFIED INVALID PARAMETER TEXT System Action: Session Manager and Measurement Services Address Space (MSAS) processing continues. User Response: If AutoStrobe monitoring is not active, verify that your installation is licensed for AutoStrobe and the Strobe installation parameter, AUTOMONITOR, is set to YES. If the action specified is not supported, verify the spelling and syntax of the MODIFY command and reissue it. If the AutoMeasure load module list is being updated, reissue the MODIFY LMLISTREF command after the AutoMeasure program list utility completes. STR1924I AUTOCANDIDATE FUNCTION HAS BEEN STARTED Explanation: The console operator issued the MVS MODIFY command to the MSAS address space in order to initiate the AutoStrobe AutoCandidate function (during this run of the MSAS only). System Action: Session manager, MSAS, and AutoStrobe continue to process. User Response: None required. STR1925I AUTOCANDIDATE FUNCTION HAS BEEN STOPPED Explanation: The console operator issued the MVS MODIFY command to the MSAS address space in order to terminate the AutoStrobe AutoCandidate function (during this run of the MSAS only). System Action: Session manager, MSAS, and AutoStrobe continue to process. User Response: None required. STR1926I ACTIVE MODIFY msasname STOPACND COMMAND REJECTED, AUTOCANDIDATE IS NOT Explanation: The console operator issued the MVS MODIFY command to the MSAS address space in order to terminate the AutoStrobe AutoCandidate function, but the AutoCandidate function was not active at the time. System Action: Session manager, MSAS, and AutoStrobe continue to process. User Response: None required. Messages Produced by Strobe 3-37 STR1927I MODIFY msasname STRTACND COMMAND REJECTED, { AUTOSTROBE IS NOT ACTIVE | AUTOCANDIDATE IS ALREADY ACTIVE} Explanation: The console operator issued the MVS MODIFY command to the MSAS address space to start the AutoStrobe AutoCandidate function, but either AutoStrobe was not active, or the AutoCandidate function was already active. System Action: Session manager, MSAS, and AutoStrobe continue to process. User Response: To start AutoStrobe, issue the MVS MODIFY command to the MSAS started task, specifying STARTAUTO. Next, if you want to start the AutoStrobe AutoCandidate function, and AUTOCANDIDATE=YES is not specified in the Strobe parameter dataset, issue the MVS MODIFY command to the MSAS started task, specifying STRTCAND. STR1935I dynaTrace start issued for job xxxxxxxx rc xx Explanation: A dynaTrace agent was found active in address space xxxxxxxx and Strobe has issued a start trace command to the dynaTrace server. The return code was xx. System Action: Strobe Measurement Address space continues to measure the address space and dynaTrace will also collect data when rc=00. User Response: If the return code is other than zero, check Strobe PARMLIB to ensure that the dynaTrace parameters are correct. STR1936I Preparing dynaTrace report for job xxxxxxxx Explanation: A dynaTrace agent was found active in address space xxxxxxxx and Strobe is about to issue a Stop trace command to the dynaTrace server. System Action: Strobe Measurement termination continues. User Response: None. No response is required. STR1937I dynaTrace stop issued for job xxxxxxxx rc xx Explanation: A dynaTrace agent was found active in address space xxxxxxxx and Strobe has issued a Stop trace command to the dynaTrace server. The return code was xx. System Action: Strobe Measurement termination continues. When rc=00, the URL for the dynaTrace data will be included in the Sample file for display by iStrobe. User Response: If the return code is other than zero, check Strobe PARMLIB to ensure that the dynaTrace parameters are correct. STR1938I dynaTrace connect failed job jjjjjjjj ttttttttttttt Explanation: The attempt to connect to the dynaTrace server failed for job jjjjjjjj. The text reason code can be the returned status code st xxxxxxxx or the URL used to attempt the connection. System Action: Strobe Measurement continues without the dynaTrace data. User Response: If a status code is returned, there may be a problem with the user ID or password used. If the URL is returned, check it to determine if it is valid. STR1940I Initialization of Strobe for WebSphere in MSASname { in process | complete} Explanation: Initialization of Strobe for WebSphere Application Server in the MSAS msasname is in process or complete. System Action: Strobe for WebSphere Application Server proceeds normally. User Response: None required. STR1941I Strobe for WebSphere has been terminated MSASIO drv task has been terminated  MSAS_DYNT drv task has been terminated  AutoStrobe task has been terminated Explanation: Strobe for WebSphere Application Server has ended. MSASIO drv task has ended. MSAS_DYNT drv task has ended. AutoStrobe task has ended. 3-38 Strobe Messages Guide System Action: Strobe for WebSphere Application Server has terminated. MSASIO drv task has been terminated.  MSAS_DYNT drv task has been terminated.  AutoStrobe task has been terminated. User Response: If Strobe for WebSphere Application Server or any of the other tasks--MSASIO drv, MSAS_DYNT drv, or AutoStrobe--terminated abnormally, proceed based on the content of any related error messages. Otherwise, none required. STR1942E INIT OF STR FOR WEBSPHERE IN msasname TERMINATED --- Explanation: Initialization of Strobe for WebSphere Application Server terminated for the reason shown in text: • CSVDYNEX ADD FOR STRvWU83 FAILED - The Strobe module, STRvWU83, could not be dynamically added to the SMF IEFU83 exit chain. • UNABLE TO OBTAIN PRIVATE WORKING STORAGE - The region for the MSAS Address Space is not large enough. The Strobe system programmer may need to increase the region size for the MSAS by changing the proc named by the MSASPROCNAME parameter in the Strobe parameter dataset. • SMF RECORD TYPE 120 NOT BEING COLLECTED - The current LPAR does not specify that SMF type 120 records be collected. Strobe for WebSphere Application Server requires that SMF type 120 records be created. • SAST IS INVALID -- Session manager and/or MSAS is passing an incorrect value to Strobe for WebSphere Application Server. The Strobe system programmer may choose to recycle Strobe for WebSphere by issuing MODIFY commands to MSAS to STOPWAS and then STARTWAS. If the problem persists, the system programmer may choose to recycle the related Session Manager Address Space. • LOAD OF STRvWU83 FAILED, ABEND CODE=Sxxx-xx - The load module STRvWU83 cannot be located. • UNABLE TO OBTAIN COMMON STORAGE FOR WAST - Common storage could not be obtained for the WAST control block. The Strobe system programmer may need to investigate why common storage is unavailable. System Action: Strobe for WebSphere Application Server cannot be initialized. User Response: Notify the Strobe system programmer. Follow any additional suggestions noted above for text. STR1944S STRvWU83 HAS ENCOUNTERED SEVERE ERROR AND WILL TERMINATE --- Explanation: See the following explanations for text: • SMF EXIT DELETED BY SYSTEM - Program STRvWU83 has abended. Strobe for WebSphere Application Server cannot continue, but will be automatically restarted up to three times per WebSphere session per MSAS session. • STRBWDRV IS ABENDING - Program STRvWDRV has abended. Strobe for WebSphere Application Server cannot continue, but will be automatically restarted up to three times per WebSphere session per MSAS session. • INVALID WAST AREA - Either STRvWDRV passed an incorrect value to STRvWU83, or common storage has become corrupted. The Strobe system programmer may choose to recycle Strobe for WebSphere Application Server by issuing MODIFY commands to MSAS to STOPWAS and then STARTWAS. If the problem persists, consider recycling the related Session Manager Address Space. System Action: Strobe for WebSphere Application Server cannot continue. See any additional system action in the description of text. User Response: Notify the Strobe system programmer, who may choose to obtain a dump and send to Compuware for analysis. Follow any additional suggestions noted above for text. STR1945E STRvWU83 WILL TERMINATE WAS { IN SINGLE REQUEST text | IN REQUEST rrrr text} • The following reasons exist when scope is IN SINGLE REQUEST text STORAGE OBTAIN OF LWA FAILED Explanation: The region for the measured Address Space, or the region for the associated WebSphere Control Address Space if you are measuring a WebSphere Server Address Space, is not large enough. This may be due to measuring several Server Address Spaces within one Control Address Space concurrently. Messages Produced by Strobe System Action: only. 3-39 Strobe for WebSphere Application Server cannot continue for this request User Response: The WebSphere system programmer may need to increase the region size for the affected WebSphere Address Space. INVALID SAST CHAIN OR AREA Explanation: The internal Strobe SAST chain or one of its related areas is invalid. Strobe for WebSphere Application Server cannot continue for this request only. Notify the Strobe system programmer, who may choose to recycle the related Session Manager Address Space. • The following reasons exist when scope is IN REQUEST rrrr text. rrrr is the number of the Strobe request. ALESERV ADD FAILED Explanation: The Strobe for WebSphere Application Server SMF exit could not obtain access rights to the dataspace obtained on its behalf by the WebSphere Application Server data collector. This is theoretically possible when there have been over 509 Strobe measurements on WebSphere Server Address Spaces within a single WebSphere Control Address Space. System Action: Strobe for WebSphere Application Server cannot continue for this request only, or for subsequent requests for WebSphere Server Address Spaces within this related WebSphere Control Address Space. User Response: Notify the WebSphere system programmer, who may chose to recycle the associated WebSphere Control Address Space. TEN INVALID SMF RECORDS TYPE 120, SUBTYPE 1 Explanation: records. The SMF exit, STRBWU83, has recognized 10 invalid type 120, subtype 1, SMF System Action: The Strobe for WebSphere Application Server data collector will cease processing SMF records for this measurement only. It will continue the measurement for all other events. User Response: Notify the Strobe system programmer, who may wish to work with your site’s SMF system programmer for a solution. TEN INVALID SMF RECORDS TYPE 120, SUBTYPE 5 Explanation: records. The SMF exit, STRBWU83, has recognized 10 invalid type 120, subtype 5, SMF System Action: The Strobe for WebSphere Application Server data collector will cease processing SMF records for this measurement only. It will continue the measurement for all other events. User Response: Notify the Strobe system programmer, who may wish to work with your site’s SMF system programmer for a solution. TEN INVALID SMF RECORDS TYPE 120, SUBTYPE 7 Explanation: records. The SMF exit, STRBWU83, has recognized 10 invalid type 120, subtype 7, SMF System Action: The Strobe for WebSphere Application Server data collector will cease processing SMF records for this measurement only. It will continue the measurement for all other events. User Response: Notify the Strobe system programmer, who may wish to work with your SMF system programmer for a solution. ONE THOUSAND SMF RECORDS LOST DURING MEASUREMENT Explanation: The SMF exit, STRBWU83, has recognized that 1,000 SMF records have been lost during this measurement due to timing issues on the dataspace it shares with the Strobe WebSphere data collector. System Action: The Strobe for WebSphere Application Server data collector will cease processing SMF records for WebSphere (type 120) for this measurement only. It will continue the measurement for all other events. User Response: Notify the Strobe system programmer. 3-40 Strobe Messages Guide STR1950E LOAD-MODULE LIST PROCESSING TERMINATED - reason Explanation: The AutoMeasure utility was unable to completely build or update the AutoMeasure load module list for the indicated reason. The possible reasons include: • • • • • • • • • • • • • • • • • • • • HISTORY INITIALIZATION FAILED UNABLE TO OPEN SYSIN DATA SET UNABLE TO READ SYSIN DATA SET NO DATE RECORD IN SYSIN DATA SET INVALID DATE RECORD IN SYSIN DATA SET SYSIN DATA CONTAINED AN INVALID RECORD TYPE UNABLE TO DELETE AN OLD LOAD-MODULE LIST NO NAME OR PREFIX SPECIFIED ON EXCLUDE RECORD UNABLE TO ALLOCATE LOAD LIBRARY - load library name ERROR WHILE READING DIR BLOCK FROM LOAD LIBRARY - load library name ERROR WHILE READING MEMBER FROM LOAD LIBRARY - load library name UNABLE TO WRITE LOAD-MODULE-LIST ENTRY UNABLE TO WRITE LOAD-MODULE-LIST HEADER UNABLE TO READ LOAD-MODULE-LIST HEADER UNABLE TO OPEN PDS DIRECTORY DCB - load library name UNABLE TO OPEN PDS MEMBER DCB - load library name NO LOAD LIBRARY DESIGNATED IN THE SYSIN DATA NUMBER OF EXCLUDE RECORDS EXCEEDS MAXIMUM UNABLE TO DELETE A LOAD-MODULE LIST ENTRY UNABLE TO OBTAIN STORAGE FOR LOAD-LIBRARY DATA System Action: The AutoMeasure utility terminates. When the reason indicates a problem with the reading, writing, or deleting of the AutoMeasure list or one of its entries, this message is preceded by diagnostic data that specifies the return and reason codes from VSAM.  Any entries put on the AutoMeasure load module list prior to this error remain intact. These entries are identified in the STR1953I message that precedes this one.  Any active Strobe and AutoStrobe processing continues. User Response: Depending on the reason, either check the input parameters on the STROBE AUTOSTROBE AUTOMEASURE UTILITY panel for submitting an AutoMeasure request or contact Compuware Customer Support. STR1951E NO LOAD-MODULE LIST BUILT FOR AUTOMEASURE FUNCTION - reason Explanation: During AutoStrobe initialization, Strobe was unable to build a version of the AutoMeasure load module list in storage for this instance of Strobe. The possible reasons include: • • • • • • • NO LOAD MODULE LIST ON AUTOSTROBE DATA SET LIST HAS NO ENTRIES SPECIFYING THIS SYSTEM FOR AUTOMEASURE UNABLE TO OBTAIN PRIVATE STORAGE FOR LIST UNABLE TO OBTAIN COMMON STORAGE FOR LIST UNABLE TO READ HEADER RECORD FOR LIST UNABLE TO READ AN ENTRY RECORD FROM LIST INTERNAL ERROR System Action: AutoStrobe did not build a version of the AutoMeasure load module list in storage, so this instance of Strobe cannot initiate any automatic measurements of new or changed load modules. All other Strobe and AutoStrobe processing continues as usual. User Response: STR1951I Contact Compuware Customer Support. NO LOAD-MODULE LIST BUILT FOR AUTOMEASURE FUNCTION - reason Explanation: During AutoStrobe initialization, Strobe was unable to build a version of the AutoMeasure load module list in storage for this instance of Strobe. The possible reasons include: • • • • • • NO LOAD MODULE LIST ON AUTOSTROBE DATA SET LIST HAS NO ENTRIES SPECIFYING THIS SYSTEM FOR AUTOMEASURE UNABLE TO OBTAIN PRIVATE STORAGE FOR LIST UNABLE TO OBTAIN COMMON STORAGE FOR LIST UNABLE TO READ HEADER RECORD FOR LIST UNABLE TO READ AN ENTRY RECORD FROM LIST Messages Produced by Strobe 3-41 • INTERNAL ERROR System Action: AutoStrobe did not build a version of the AutoMeasure load module list in storage, so this instance of Strobe cannot initiate any automatic measurements of new or changed load modules. All other Strobe and AutoStrobe processing continues as usual. User Response: Run the AutoMeasure program list utility to build the load module list and issue the MODIFY STRBMSAS, LMLISTREF command. STR1952I AUTOMATIC MEASUREMENT SUPPRESSED FOR PROGRAM - program name Explanation: The AutoMeasure load module list specified a program name for an automatic measurement, but AutoStrobe did not initiate the measurement for one of the following reasons: • ALREADY MEASURED UNDER CURRENT JOB AND STEP • MAXIMUM NUMBER OF AUTOMEASURES ALREADY TAKEN • AUTOMEASURE TEMPLATE SRE HAS BEEN DELETED System Action: AutoStrobe does not initiate the automatic measurement of the designated program for the specified reason. User Response: STR1953I None required. {number of entries ENTRIES | NO ENTRIES} ADDED TO LOAD-MODULE LIST Explanation: This message appears after AutoStrobe builds the AutoMeasure load module list. The following are possible reasons for this message: • The list was not built or updated. • To provide the number of load module names placed on the AutoMeasure load module list. When entries are put on the AutoMeasure load module list, this message is preceded by a list of the load module names that were added and their link-edit dates. System Action: Processing continues. User Response: If this message indicates that no entries were placed on the AutoMeasure load module list, check that the correct parameters were used when running the AutoMeasure utility. STR1954I IN-STORAGE VERSION OF AUTOMEASURE LOAD-MODULE LIST {REFRESHED | BUILT} CONTAINS number ENTRIES Explanation: The version of the AutoMeasure load module list in storage that identifies the load modules to be automatically measured on this z/OS system has been successfully built (during Measurement Services Address Space initialization) or refreshed (using the z/OS MODIFY operator command) from the AutoMeasure load module list in the AutoStrobe dataset. System Action: Strobe and AutoStrobe processing continues normally. User Response: None. STR1960I NO TRANSACTION-CANDIDATE LIST BUILT FOR CICS REGION jobname FOR TIME PERIODS SPECIFIED IN REQUEST xxxx Explanation: The AutoStrobe Create Transaction Candidates request xxxx has completed. AutoStrobe did not build a list of transaction candidates from the CICS region, because either no transactions executed or none of the transactions that executed had enough activity to exceed the minimum thresholds specified in the request. System Action: AutoStrobe processing continues. User Response: Verify that there is sufficient activity in the CICS region during the time period(s) specified on the AutoStrobe Create Transaction Candidates request. If there is, you should delete this request and submit another one using lower minimum thresholds, lower execution counts, or different time periods. 3-42 Strobe Messages Guide STR1961E AUTOSTROBE REQUEST xxxx FOR JOB jobname MARKED COMPLETE BECAUSE OF AN ERROR - CODE=xx [,SUBCODE=cc] Explanation: An error occurred while AutoStrobe was processing a Create Transaction Candidates request or a transaction monitoring request for a CICS region. CODE=xx identifies the function in which the error occurred and SUBCODE=cc, if present, provides further details. System Action: AutoStrobe marks the request as complete. Other Strobe and AutoStrobe processing continues. User Response: Save the Strobe log in which this error appears and contact Compuware Customer Support. STR1962I AUTOSTROBE MONITORING FOR REQUEST xxxx FOR JOB jobname SUSPENDED FOR A USER-INITIATED MEASUREMENT OF REGION Explanation: A user initiated a measurement for a job in a CICS region monitored by AutoStrobe. AutoStrobe stops monitoring the CICS region, so the measurement can proceed. System Action: When the measurement ends: • For a transaction monitoring request, AutoStrobe resumes monitoring the CICS region. • For a Create Transaction Candidates request, no more data is collected during this time period, and any data collected during this time period is discarded. AutoStrobe resumes collecting data at the start of the next time period. User Response: None required. STR1963I AUTOSTROBE DATA COLLECTION FOR REQUEST xxxx FOR JOB jobname DEFERRED UNTIL START OF THE NEXT TIME PERIOD Explanation: A Create Transaction Candidates request was submitted during a time period that had already started as specified in the request. Because Create Transaction Candidates requests process data only for complete time periods, data collection for this request is deferred until the start of the next time period. System Action: AutoStrobe processing continues. User Response: None required. STR1968E MSAS_DYNT Driver GetHost Failed eeeeeeee Explanation: The Measurement Services task MSAS_DYNT has failed during initialization with error eeeeeeee. Error is in the GETHOST routine. This may occur when the MSAS address space is not authorized to use TCP/IP. System Action: Processing continues. If you receive a GETHOST error, the dynaTrace interface in Strobe is disabled. User Response: None required. If you receive a GETHOST error, check to see that the MSAS address space has a RACF user ID and an OMVS segment to allow TCP/IP to be used. STR1968I MSAS IO Driver MSAS_DYNT Driver Explanation: initialized and waiting for work initialized and waiting for work The Measurement Services tasks have been started and are waiting for work. System Action: Processing continues. If you receive a GETHOST error, the dynaTrace interface in Strobe is disabled. User Response: None required. If you receive a GETHOST error, check to see that the MSAS address space has a RACF user ID and an OMVS segment to allow TCP/IP to be used. STR1969E Load failed for service provider module modulename. Explanation: Strobe invoked an MVS service to load a module, but the load request failed. System Action: Strobe initiation terminates. User Response: Notify the Strobe system programmer. STR1970I cccccccccccccccc rrrrrrrrrr RETCODE=xxxxxxxx ERRNO=xxxxxxxx Explanation: This message is issued in response to TCP/IP communications using the IBM API, EZASMI, where: Messages Produced by Strobe 3-43 cccccccccccccccc is the EZASMI API function command. rrrrrrrrrr is the command result: SUCCESS or FAIL. RETCODE=xxxxxxxx is the EZASMI return code. ERRNO=xxxxxxxx is the EZASMI error number. System Action: Processing continues. User Response: None required, unless the function command result is FAIL. If this is the case, check your TCP/IP settings and connections. STR197II cccccccccccccccc rrrrrrrrrr IP ADDRESS=xxxxxxxx Explanation: This message is issued in response to TCP/IP communications using the IBM API, EZASMI, where: cccccccccccccccc rrrrrrrrrr IP ADDRESS=xxxxx System Action: is the EZASMI API function command. is the command result: SUCCESS or FAIL. is the IP ADDRESS of the HOST. Processing continues. User Response: None required, unless the function command result is FAIL. If this is the case, check your TCP/IP settings and connections for your VantageView server. STR1972E EZASMI RECV TIMED OUT -- CANCELING REQUEST Explanation: API, EZASMI. System Action: This message is issued in response to TCP/IP communications using the IBM Processing continues. User Response: Strobe has not received a response within the expected time. If this is the case, check your TCP/IP settings and connections for your VantageView server. STR1973E EZASMI GETHOSTID failed Explanation: API, EZASMI. System Action: This message is issued in response to TCP/IP communications using the IBM Processing continues. User Response: If this is the case, check your TCP/IP settings and connections for your VantageView server. STR1974I cccc Buffer: xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Explanation: This message is issued in response to TCP/IP communications using the IBM API, EZASMI, where: cccc Buffer: xxxxxxxx is the EZASMI API function command. is the data from the RECV or SEND function. System Action: Processing continues. User Response: None required. STR1975E Timeout on CONNECT, Host Unreachable. Explanation: API, EZASMI. System Action: This message is issued in response to TCP/IP communications using the IBM Processing continues. User Response: Strobe has not received a response within the expected time. If this is the case, check your TCP/IP settings and connections for your VantageView server. STR1976E EZASMI GETHOSTBYADDR failed Explanation: API, EZASMI. System Action: This message is issued in response to TCP/IP communications using the IBM Processing continues. User Response: If this is the case, check your TCP/IP settings and connections for your VantageView server. 3-44 Strobe Messages Guide STR1977E ATTACH for xxxxxxxx module mmmmmmmm failed r/c rrrrrrrr Explanation: This message is issued when Strobe experiences an ATTACH failure during processing, where: xxxxxxxx mmmmmmmm rrrrrrrrrr is the functional part of Strobe that experienced the failure. is the name of the load module to be attached. is the ATTACH return code. System Action: The Reporter/download task terminates. User Response: Notify the Strobe system programmer. STR1980I Global Monitoring has been started Explanation: The Global Monitoring task has been attached in the MSAS. System Action: Processing continues. User Response: None required. STR1981I Strobe Global Monitoring initializing in (msasname) Explanation: The Global Monitoring task is in the process of initializing in the MSAS. The name of the MSAS procedure is displayed in the message. System Action: Processing continues. User Response: None required. STR1982I Strobe Global Monitoring initialization complete in (msasname) Explanation: The Global Monitoring task has completed initializing in the MSAS. The name of the MSAS procedure is displayed in the message. System Action: Processing continues. User Response: None required. STR1983I Global Monitoring file task has been started Explanation: The Global Monitoring file task has been attached in the MSAS. System Action: Processing continues. User Response: None required. STR1984I Strobe Global Monitoring file task initializing in (msasname) Explanation: The Global Monitoring file task is in the process of initializing in the MSAS. The name of the MSAS procedure is displayed in the message. System Action: Processing continues. User Response: None required. STR1985I Strobe Global Monitoring file task initialization complete in (msasname) Explanation: The Global Monitoring file task has completed initializing in the MSAS. The name of the MSAS procedure is displayed in the message. System Action: Processing continues. User Response: None required. STR1986I Strobe Global Monitoring terminating in (msasname) Explanation: The Global Monitoring task has started termination processing in the MSAS. The name of the MSAS procedure is displayed in the message. System Action: Processing continues. User Response: None required. STR1987I Strobe Global Monitoring file task terminating in (msasname) Explanation: The Global Monitoring file task has started termination processing in the MSAS. The name of the MSAS procedure is displayed in the message. Messages Produced by Strobe System Action: Processing continues. User Response: None required. STR1988I Strobe Global Monitoring file task has terminated Explanation: MSAS. The Global Monitoring file task has completed termination processing in the System Action: Processing continues. User Response: None required. STR1989I Strobe Global Monitoring has terminated Explanation: MSAS. The Global Monitoring task has completed termination processing in the System Action: Processing continues. User Response: None required. STR1990E 3-45 Error allocating Global Monitoring Repository data set Explanation: The Global Monitoring task has attempted to dynamically allocate the repository data set. The attempt was not successful. System Action: Global Monitoring terminates in the MSAS. User Response: See the subsequent STR1991I message for details about this error. STR1991I Dynalloc RC=rrrrrrrr. Error=eeee. Reason Code=cccc Explanation: This message displays the dynamic allocation return code, error code, and reason code. The previous message indicates the file that was being allocated. System Action: Global Monitoring processing continues. User Response: Using the return code, error code, and reason code, determine the cause of the dynamic allocation failure. STR1992E Error allocating Global Monitoring AUTOHIST data set Explanation: The Global Monitoring task has attempted to dynamically allocate the Autostrobe history file. The attempt was not successful. System Action: Global Monitoring terminates in the MSAS. User Response: See the subsequent STR1993I message for details about this error. STR1993I Dynalloc RC=rrrrrrrr. Error=eeee. Reason Code=cccc Explanation: This message displays the dynamic allocation return code, error code and reason code. The previous message indicates the file that was being allocated. System Action: Global Monitoring processing continues. User Response: Using the return code, error code, and reason code, determine the cause of the dynamic allocation failure. STR1994I Global Monitoring criteria refreshed Explanation: This message indicates that the Global Monitoring criteria have been successfully refreshed from the AutoStrobe data set. This occurs when the GMCRITREF option is passed to the MSAS using the MVS MODIFY command. System Action: Global Monitoring processing continues with the new criteria. User Response: None required. STR1995E Global Monitoring criteria refresh failed. RC=rrrrrrrr Explanation: A request to refresh the Global Monitoring criteria was unsuccessful. The return code is indicated in the message. System Action: Global Monitoring processing continues. User Response: Contact Compuware Customer Support. 3-46 Strobe Messages Guide STR1996E Invalid Global Monitoring Repository data set name prefix specified. Explanation: The value specified in the GM_REPOSITORY_DSN Strobe parameter must be a valid data set name prefix. System Action: Global Monitoring terminates in the MSAS. User Response: parameter. Specify a valid data set name prefix on the GM_REPOSITORY_DSN Strobe STR1997E Global Monitoring Repository data set name prefix greater than 38 characters. Explanation: The value specified in the GM_REPOSITORY_DSN Strobe parameter cannot be greater than 38 characters in order to allow Strobe to append the system ID low-level qualifier. The system ID low-level qualifier consists of the letter “S” and the four-character SMF system ID. System Action: Global Monitoring terminates in the MSAS. User Response: Specify a valid data set name prefix on the GM_REPOSITORY_DSN Strobe parameter that is less than or equal to 38 characters. STR1998E Global Monitoring Repository data set already in use Explanation: The Global Monitoring repository data set can be used by only one Strobe image running on an LPAR. System Action: Global Monitoring terminates in the MSAS. User Response: LPAR. Create a separate repository data set for each image of Strobe running on an STR1999I Global Monitoring Repository data set name xxxxxxxxxxxxxx. Explanation: name. This message displays the 44-character Global Monitoring Repository data set System Action: Global Monitoring initialization continues. User Response: None required. Messages Returned by the Reporter The Strobe Reporter program returns the following messages. STR2000I PARM=parm Explanation: Strobe detected an error in one or more of the parameters specified. System Action: Strobe lists one line of the parameters in parm and repeats this message once for each additional line. User Response: Verify that the parameters have been specified correctly. If they have, notify the Strobe system programmer. STR2002W ERROR IN PARAMETER parmname [parmvalue] [explanation] Explanation: Strobe detected an error in the parameter parmname. If the parameter has a value, that value appears in parmvalue. If further information is available, it appears in explanation. System Action: Strobe continues processing. If the error Strobe encountered is a table overflow error, Strobe processes only as many modules as it can fit in the table. User Response: Review the input parameters to ensure that they are correct. Refer to “Creating Performance Profiles Using Procedures” in the Strobe User Guide for more information. STR2003W SQL PARAMETER MAXLEN CHANGED TO new value Explanation: MAXLEN must be a multiple of 100. System Action: The Reporter increases the value of MAXLEN to the next highest multiple of 100, which appears as a new value. Messages Produced by Strobe User Response: STR2004W 3-47 Change MAXLEN to be a multiple of 100. CONFLICTING REPORT PARAMETERS: parm1 - parm2 Explanation: request. Two conflicting parameters, parm1 - parm2, were supplied to the profiling System Action: Strobe ignores the conflicting parameter and uses the default parameters. User Response: Remove one of the parameters. STR2005W INVALID TRANSACTION FILTER REQUEST. THE FORMAT OF THE TRANSACTION FILTER tran IS NOT VALID Explanation: The specified filter tran is not one to four characters long with a wildcard (*) in the last position. If a set of transactions is filtered, the last significant character must equal an asterisk (*). System Action: Strobe ignores the filter request and does not provide performance information for that set of transactions. User Response: Enter a valid transaction name with a wildcard in the last position. Refer to the IBM CICS Resource Definition Guide for valid CICS transaction names. STR2006W MORE THAN FIVE TRANSACTION FILTER REQUESTS WERE SPECIFIED Explanation: Strobe can report detailed performance information for only five transactions or sets of transactions. System Action: only. Strobe provides detailed performance information for the first five requests User Response: Verify the number of filter requests and remove additional requests. STR2007W INVALID {TLIBASE|RLIBASE} PARAMETER Explanation: of 99.999. You entered a value for TLIBASE or RLIBASE that exceeds the maximum value System Action: Strobe uses the default values of 00.005 seconds. User Response: Enter a valid value. STR2008I DUPLICATE PARAMETERS ENCOUNTERED- Explanation: parm1 You entered the same parameter, parm1, twice. System Action: Strobe ignores the second parameter. User Response: Remove the duplicate parameter from the Profile request. STR2009I DUPLICATE TRANSACTION PROFILE REQUESTS SUBMITTED - tran Explanation: tran. You requested duplicate performance information for the transaction named System Action: Strobe ignores the second transaction. User Response: Remove the duplicate transaction from the Profile request. STR2050W HISTORY ALREADY EXISTS FOR jobname/stepname/progname date time reqnumber Explanation: A measurement session history record already exists for the sample file identified by the job jobname, the step stepname, and the program progname. This measurement session history record was created on date date and time time. The Strobe request number for the sample dataset was reqnumber. System Action: Strobe continues creating a Performance Profile, but will not create a new measurement session history record. User Response: None required. If you verify that this sample file is the sample file for which you now want to add information to the history database, you must first delete its existing measurement session history record. You can then create a new measurement session history record for this sample file. 3-48 Strobe Messages Guide STR2051W UNABLE TO LOAD STROBE HISTORY MANAGER Explanation: System Action: Strobe was unable to locate its history manager component. Strobe will not update the history dataset. User Response: Review the Strobe history manager installation instructions in the Strobe Installation and Customization Guide and verify that the appropriate Strobe libraries are loaded. If the problem persists, contact Compuware Customer Support. STR2052W UNABLE TO CALCULATE fieldname FOR {TRANSACTION | DBRM} NAME name Explanation: Strobe encountered either an overflow or an underflow condition and was unable to calculate the statistics given in fieldname for either the transaction or DBRM name identified in name. System Action: Strobe will set the field identified in fieldname to zero. Some information in the history dataset will be incomplete. User Response: STR2053W None required. COLLECTION OF HISTORY DATA IS TERMINATED Explanation: failed. System Action: be created. The request for a measurement session history record for this measurement Strobe continues processing but no measurement session history record will User Response: Follow the response indicated in any accompanying Strobe messages that relate to measurement session history collection and reporting. If you entered the REPJOB or REPSTP parameters, ensure that you used the correct syntax. STR2104W MAP DATA SET CONTAINS AN UNMAPPED CONTROL SECTION NAMED csectname Explanation: Map dataset information is compiled for the control section csectname, but this control section does not appear in the sample dataset. The following are possible causes: • The control section exhibited less than the baseline percentage of execution samples specified with the BASELINE operand (default 2). • A library in the STEPLIB, JOBLIB, or STRBLIB data definition statements does not have the correct name. • The named library or libraries do not contain the named module. • The named module is resident in the link pack area and your Strobe system programmer has not configured your Strobe system to obtain data from link pack area libraries. • The job step was cancelled or timed out, preventing mapping. • The control section contained one or more modules that were loaded with the Dynamic LPALIB Facility. System Action: The Reporter continues execution but does not process Indexer data for the control section. User Response: Check the BASELINE field on the Measurement Session Data report. If the BASELINE field does not appear on the report, Strobe used the default baseline.  Check that the map dataset supplied to the Reporter is the proper map of the correct program. It must be the map dataset of the program whose execution samples appear in the sample dataset.  Check for error messages produced by the measurement task that may indicate problems processing the load library. If the measurement task is unable to map the load module, the Reporter cannot accept the Indexer data. STR2105W ERROR ADDING 4GL PROGRAM program TO CSECT TABLE FOR MODULE modname Explanation: There is no room in an internal table to add the 4GL program named program. System Action: incomplete. The Reporter continues processing, but some attribution data may be User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR2106W 3-49 TOO MANY USER-SUPPLIED PSEUDO-CSECT NAMES Explanation: You supplied more than the maximum number of names allowed in the COMPRES parameter. System Action: Strobe does not report as pseudo-procedures activity in other modules with names that have been supplied by a user-written or a Strobe data collector program, or in the COMPRES parameter. It shows them as normal modules or control sections. The number of groups compressed with the COMPRES option and by data collector programs cannot total more than 25. User Response: Review the description of the COMPRES parameter. STR2108W ADDRESS NOT MAPPED - SAMPLE sampnumber PSW psw modname BASE base SIZE size MAP SIZE mapsize Explanation: The PSW is not in a mapped portion of the module, but the Reporter detected fewer than 100 instances of the problem. The sample number is sampnumber, the PSW is psw, the module is modname, the base is base, the size is size, and the map size is mapsize. System Action: The Reporter discards the sample and continues processing. User Response: Notify the Strobe system programmer. STR2109S ADDRESS NOT MAPPED - SAMPLE sampnumber PSW psw modname BASE base SIZE size MAP SIZE mapsize Explanation: The PSW is not in a mapped portion of the module, and the Reporter has detected more than 100 instances of the problem. The sample number is sampnumber, the PSW is psw, the module is modname, the base is base, the size is size, and the map size is mapsize. System Action: The Reporter terminates and does not produce a Strobe Performance Profile. User Response: Notify the Strobe system programmer. STR2110E TOO MANY CONTROL SECTIONS Explanation: Strobe was unable to acquire sufficient storage to table all control sections for which mapping data may be required. System Action: Strobe produces a Profile but might discard mapping data for some modules if its internal table cannot store all the information. If any mapping data is discarded, this message is followed by one or more occurrences of the message STR2108W, giving the names of the affected modules. User Response: Notify the Strobe system programmer. STR2111S TOO MANY {MODULES|DD STATEMENTS|I/O UNIT|VOLUME|SEGMENTS|FILE NAME COMBINATIONS} Explanation: Input to the Strobe Reporter exceeded the Reporter’s capacity. The limits are as follows: Load modules 3196 Segments 255 DD statements 2119 Unit/volume/ddname combinations for datasets 2500 System Action: The Reporter does not produce a Strobe Performance Profile. User Response: Notify the Strobe system programmer. STR2112W PROFILE CREATED USING A LOW NUMBER OF EXECUTION SAMPLES Explanation: The Reporter found fewer than 100 execution samples in the sample dataset. The measurement session was too short or the initial sampling rate was too low. System Action: Strobe produces a Performance Profile but the CPU reports are not statistically significant. User Response: Rerun the measurement session, and specify a smaller estimate of minimum run time or a larger target sample size or both. 3-50 Strobe Messages Guide STR2113E FEWER THAN 100 SAMPLES - NO PROFILE PRODUCED Explanation: Fewer than 100 samples are in the sample dataset. The measurement session was too short or the initial sampling rate was too low. System Action: Strobe does not produce a Performance Profile. User Response: Rerun the measurement session, and specify a smaller estimate of minimum run time or a larger target sample size or both. STR2114W TOO MANY SETS OF WORK LOAD MANAGER INFORMATION Explanation: information. Insufficient storage was available to build a table of all Workload Manager System Action: Strobe produces a Profile but there will be some Workload Manager information missing. User Response: STR2116S Notify the Strobe system programmer. UNSUCCESSFUL COMPLETION OF SORT. SORT RETURN CODE=rc Explanation: The installation-supplied sort/merge program did not complete execution successfully. The return code returned by the sort/merge program is rc. System Action: Strobe does not produce a Performance Profile. User Response: Review the messages produced by the sort/merge program to determine the cause of the problem. STR2118S SAMPLE DATA SET IMPROPERLY FORMATTED Explanation: The samples in the sample dataset are out of sequence, probably because the Reporter has been executed before the dataset has been closed by the measurement task. System Action: Strobe does not produce a Performance Profile. User Response: Ensure that the dataset is closed and resubmit the job. STR2120S INSUFFICIENT SPACE ON WORK FILE Explanation: The Reporter SYSUT1 dataset used all of its allocated direct access extents. System Action: Strobe does not produce a Performance Profile. User Response: Rerun the Reporter with a larger space allocation for the SYSUT1 dataset. STR2122W NOT AGREE MAP DATA SET AND LOAD LIBRARY SIZES FOR CONTROL SECTION csectname DO Explanation: The size of a control section, csectname, as reported by the Indexer in the map dataset, differs from the size the measurement task determined from the load library. System Action: The Reporter uses data in the map dataset, but the assignment of CPU time by procedure in the Strobe Performance Profile may be incorrect. However, some compiler options (such as the COBOL STATE option) extend a control section beyond the length reflected in the object code listing the Indexer processed. When such an option is in effect, this message will appear, but the Performance Profile will still be valid. User Response: Ensure that you compiled and indexed the same source that was compiled to produce the measured program load module for the program. Ensure also that you used the same compiler options. To be sure, compile, index, and link edit the program again, and then perform another measurement session. STR2124W TOO MANY TASKS Explanation: Data for more than 563 tasks was placed in the sample dataset. System Action: Strobe produces the Performance Profile, but the activity for all tasks will be compressed into one detail line in the Time Distribution of Activity Level and Resource Demand Distribution reports. User Response: Notify the Strobe system programmer. Messages Produced by Strobe 3-51 STR2125W {SUBSYSTEM|MAPPROG LIST|STRBLIB LIST|WAIT EXCLUDE|DATA COLLECTION| REPORT TITLE|DB2 PROCEDURE|QUERY STATEMENT} TABLE OVERFLOW Explanation: An overflow occurred in an internal table of the Strobe Reporter program. System Action: inaccurate. Strobe produces a Performance Profile, but some data may be missing or User Response: Notify the Strobe system programmer. STR2126W LENGTH ERROR ON {SUBSYSTEM |WAIT EXCLUDE|DATA COLLECTION} TABLE Explanation: Strobe detected an internal item length error in a Strobe subsystem, mapping list, or library list while processing the Strobe Performance Profile. System Action: Strobe produces a Performance Profile, but the Measurement Session Data report is missing the corresponding data. User Response: Notify the Strobe system programmer. STR2127W OVERLAY CSECT NOT IN MAIN STORAGE - MODULE modname CSECT csectname COUNT errorcount Explanation: Strobe attempted to sample an overlay segment that maps to module modname and segment csectname errorcount times, but the segment was not in virtual storage. System Action: Strobe shows activity relative to the module base for the module modname. User Response: Notify the Strobe system programmer. STR2128W OVERLAY CSECT NOT IN MAIN STORAGE - SAMPLE sampnumber PSW psw modname BASE base SIZE size Explanation: No overlay segment that maps the PSW psw was in virtual storage when Strobe collected sample number sampnumber. System Action: Strobe shows activity relative to the module base for the module modname. The base is base, and the size is size. User Response: STR2129C Notify the Strobe system programmer. MISSING OVERLAY CSECTS MAXIMUM EXCEEDED Explanation: While sampling, Strobe encountered more than 50 overlay segments that were not in virtual storage. System Action: Strobe produces a Performance Profile, but some data in it may be inaccurate. User Response: Notify the Strobe system programmer. STR2130S {OPEN|CLOSE|READ|WRITE} ERROR ON DDNAME {STRSAMPL| SYSPRINT|SYSUT1} FILE STATUS = status Explanation: The Reporter encountered an open, close, read, or write error while accessing the sample file STRSAMPL, the report file SYSPRINT, or an internal file SYSUT1. The file status is status. If access to SYSPRINT caused the problem, the Reporter displays this message on SYSOUT. System Action: The Reporter terminates and does not produce a Performance Profile. User Response: programmer. Verify the dataset name. If the name is correct, notify the Strobe system STR2131W = status {OPEN|CLOSE|READ|WRITE} ERROR ON DDNAME {STRMAP|SORTWORK} FILE STATUS Explanation: The Reporter encountered an open, close, read, or write error while accessing the map dataset STRMAP or the SORTWORK files. The file status is status. System Action: available. The Reporter produces a Performance Profile, but no indexing data is User Response: Verify the map dataset name. If the name is correct, notify the Strobe system programmer. 3-52 Strobe Messages Guide STR2132I SECTION MAPPING CANNOT BE PERFORMED FOR THESE MODULE(S): module. IF MULTIPLE INSTANCES OF A MODULE HAVE BEEN MEASURED, THEIR ACTIVITY IS COMBINED. Explanation: The Reporter detected an inconsistency between a module found during the sampling process and module mapping information obtained from a load library. Strobe issues this message if the module that should have been mapped resides in a library that was not the first library in which a different module with the same name was found. For example, Strobe issues this message when third-party software loads modules in a manner other than that specified by IBM standards. The order in which Strobe searches libraries to obtain module mapping data is specified in the Strobe User Guide. System Action: The Reporter discards all mapping data and shows the locations of activity relative to the base address of the module instead of to the start of individual sections within the module. User Response: If a copy of the module that should have been mapped resides in a library later in the search order than the library in which Strobe found a different module with the same name, then specify the appropriate library in the Strobe request. Otherwise, notify the Strobe system programmer. STR2132I SECTION MAPPING CANNOT BE PERFORMED FOR THESE MODULE(S): STR2132I {module} STR2132I IF MULTIPLE INSTANCES OF A MODULE HAVE BEEN MEASURED, THEIR ACTIVITY IS COMBINED. Explanation: The Reporter detected an inconsistency between a module found during the sampling process and module mapping information obtained from a load library.  Strobe issues this message if the module that should have been mapped resides in a library that was not the first library in which a different module with the same name was found. For example, Strobe issues this message when third-party software loads modules in a a manner other than that specified by IBM standards.  The order in which Strobe searches libraries to obtain module mapping data is specified in the Strobe User Guide. System Action: The Reporter discards all mapping data and shows the locations of activity relative to the base address of the module instead of to the start of individual sections within the module. User Response: If a copy of the module that should have been mapped resides in a library later in the search order than the library in which Strobe found a different module with the same name, then specify the appropriate library in the Strobe request. Otherwise, notify the Strobe system programmer. STR2133S Sample dataset is invalid Explanation: The Reporter encountered an error while accessing the sample file STRSAMPL. Either the RECFM is fixed, or the measurement session information record is missing. System Action: The Reporter terminates and does not produce a Performance Profile. User Response: programmer. Verify the dataset name. If the name is correct, notify the Strobe system STR2135S Sample dataset OPEN error. Explanation: STRSAMPL. The Reporter encountered an I/O error while opening the sample file System Action: The Reporter terminates and does not produce a performance profile. User Response: programmer. Verify the dataset is a valid Sample Dataset and notify the Strobe system Messages Produced by Strobe STR2137S 3-53 Sample dataset is empty. Explanation: The Reporter encountered an error while accessing the sample file STRSAMPL. There is no data on in the dataset. System Action: The Reporter terminates and does not produce a performance profile. User Response: programmer. Verify the dataset name. If the name is correct, notify the Strobe system STR2140W INDEX DATA FOR {modname | dialog, process} FROM A MAP DATA SET HAS NO MATCHING SAMPLE DATA Explanation: Strobe produced map dataset information for the module, ADS/O dialog, or DBRM named in modname, dialog, or process, but this information does not appear in the sample dataset. System Action: The Reporter continues execution but does not process Indexer data for the module, dialog, or DBRM. User Response: Check that the map dataset supplied to the Reporter is the proper map of the correct program. It must be the map dataset of the program whose execution samples appear in the sample dataset.  Check for errors produced by the measurement task that may indicate problems processing the partitioned dataset. If the measurement task has not gathered sampling data for the module, the Reporter cannot accept the Indexer data. STR2141W modname MAP DATA SET VERSION DOES NOT MATCH SAMPLE DATA SET VERSION OF Explanation: The time stamp of module, ADS/O dialog, or DBRM (named in modname) reported by the Indexer in the map dataset differs from the time stamp reported by the measurement task. System Action: The Reporter discards the indexing data for that module, dialog, or DBRM and continues processing. User Response: Check that the map dataset supplied to the Reporter is the proper map of the correct program. It must be the map dataset of the program whose execution samples appear in the sample dataset. STR2142W RECEIVED AN INVALID TITLE FROM {SAMPLE NUMBER samnumber| indexname} TITLE TYPE =type Explanation: The Reporter encountered an invalid title of type type from either the sample dataset with sample number sampnumber or the Indexer program named indexname. System Action: The Reporter produces a Performance Profile and attributes all CPU activity caused by the DBRM with an invalid title to the default title CPU USAGE BY STATEMENT. User Response: STR2143W Notify the Strobe system programmer. NO ATTRIBUTION DATA FOR SQL IN sqlname Explanation: Strobe for DB2 identified SQL procedure or query sqlname as executing in the target address space, but it did not attribute any CPU or wait activity to that procedure or query. System Action: Strobe produces a Performance Profile, but information for the procedure or query will be missing. User Response: Rerun the measurement session and specify a larger target sample size. STR2144W DURING MEASUREMENT THERE WAS AN EXTENDED PERIOD OF TIME DURING WHICH STROBE COULD NOT SAMPLE Explanation: Strobe was unable to sample consistently during the measurement session. Because Strobe runs under a task while measuring, certain events may prevent Strobe from sampling. For example, Strobe may attempt to sample during a non interruptible unit of work, such as a type 1 SVC.   Strobe does not report activity during such events, but the rest of the measurement continues 3-54 Strobe Messages Guide to be valid. This message appears when Strobe cannot identify activity for a significant percentage of the time. System Action: Strobe produces a Performance Profile, but it may be incomplete. User Response: Rerun the measurement session, requesting 10,000 samples. If you continue to receive the message, use other tools such as GTF trace to identify the activity that Strobe cannot. STR2145S ERROR - SAMPLE FILE VERSION (ver) IS NOT CONSISTENT WITH REPORTER LEVEL (lvl) Explanation: file. The level (lvl) of the Reporter was lower than the version (ver) of the sample System Action: Strobe produces a Performance Profile, but it might be invalid. User Response: Rerun the measurement session with the correct level of the Reporter. STR2146E SAMPLE FILE SEQUENCE ERROR FOLLOWING SAMPLE NUMBER sample Explanation: The Reporter detected an out-of-sequence condition in the sample dataset following sample sample. System Action: incomplete. Strobe continues processing and creates a Performance Profile but it will be User Response: Notify the Strobe system programmer. STR2147W ONE OR MORE TRANSACTIONS EXECUTED, BUT STROBE WAS UNABLE TO REPORT ON ASSOCIATED TRANSACTION COUNTS OR SERVICE TIME Explanation: Strobe detected transactions executing but could not report on their transaction counts or service time. This could have been caused by the DL/I capture facility disabling itself. System Action: Strobe continues processing. In the Performance Profile, the Transaction Summary Report includes CPU usage for the transactions but does not include their transaction counts or service time. User Response: programmer. Check the Strobe log for additional messages and notify the Strobe system STR2148I EXECUTION COUNT DATA FOR TRANSACTION(S) OR DIALOG(S) NOT AVAILABLE. **** INDICATES MISSING DATA Explanation: Strobe could not provide execution counts for one or more transactions or dialogs. The symbol **** appears in the execution count field of any transaction or dialog for which data was unavailable. Possible reasons for the data being unavailable include – a counter rolled over – a counter was reset – a transaction and its associated counter were dynamically deallocated System Action: Strobe produces a Performance Profile, but one or more execution count fields are flagged with **** to indicate missing data. User Response: STR2150W None required. To obtain the missing data, rerun the measurement session. UNDEFINED RESOURCE CLASS ENCOUNTERED -- RESOURCE CLASS=class Explanation: Strobe encountered an unknown resource class class. System Action: Strobe reports statistics for the class under the pseudo-section .NONCICS. User Response: Notify the Strobe system programmer. STR2151W UNDEFINED RESOURCE TYPE ENCOUNTERED -- RESOURCE TYPE=type Explanation: Strobe encountered an unknown resource type, type. System Action: Strobe reports the statistics for the class under the pseudo-section.NONCICS. User Response: Notify the Strobe system programmer. STR2152W INVALID TRANSACTION PROFILING SERVICE TIME DATA Explanation: Strobe did not obtain a transaction count. Messages Produced by Strobe System Action: 3-55 Strobe substitutes a value of 1 for calculation purposes. User Response: Measure the application again. If the problem persists, notify the Strobe system programmer. STR2153W CLASS NOT MAPPED - MODULE modname, CLASS class PSW nnnnnnnn Explanation: The PSW, nnnnnnnn, does not fall within a mapped method for the class, class, but the class is identified to contain methods. System Action: Activity is reported at the class level. User Response: Measure the application again. If the problem persists, notify the Strobe system programmer. STR2154W UNABLE TO PROCESS TRANSACTION PROFILE REQUEST FOR TRANSACTION- tran Explanation: Strobe could not capture the necessary data to process the request for transaction, tran. System Action: tran. The Strobe Performance Profile reports are inaccurate for this transaction, User Response: Measure the application again. If the problem persists, notify the Strobe system programmer. STR2155W LICENSE VERIFICATION FAILED RETURN CODE =rc REASON CODE = erc. INDEXING SUPPRESSED FOR language Explanation: License verification for language failed. The return code is rc and the error reason code is erc. System Action: Strobe creates a Performance Profile, but it does not contain indexing information for language. User Response: STR2156W Contact Compuware Customer Support. LOAD FAILED FOR MODULE modname Explanation: Module modname did not load. System Action: information. Strobe creates a Performance Profile but it does not contain indexing User Response: Notify the Strobe system programmer. STR2157W ISTROBE IS NOT LICENSED Explanation: iStrobe is not licensed for your site. System Action: iStrobe does not initialize. User Response: Notify the Strobe system programmer. STR2158I ERROR PROCESSING DDIO FILE. RETURN CODE=xxxx. DDIO REASON CODE = nnnn Explanation: The Reporter failed to access indexing information from the Compuware Shared Services (CSS) DDIO database. The return code is xxxx. The CSS reason code is nnnn. System Action: Strobe continues creating a Performance Profile but the Profile will not contain indexing information from the DDIO database. User Response: When the return code = 12, the most likely cause is that Strobe could not find the CSS interface module, CWPIDRVB. Ensure that the UI_STRCSS field of the Strobe PARMLIB member specifies the load library where module CWPIDRVB is located (the load library where CSS was installed). If you are creating the Performance Profile in background, ensure that the CSS load library is concatenated in STEPLIB. When the return code = 8 and the DDIO reason code = 176, either no DDIO file was provided or the file provided was not in a proper DDIO format. DDIO files are identified in JCL by DD statements in the following format: //SLSF00n DD DISP=SHR,DSN=DDIO.LISTING.FILE where n is a number from 1 - 8. 3-56 Strobe Messages Guide For other combinations of return code and reason code values, notify the Strobe system programmer. STR2159I DDIO LISTING AND LOAD LIBRARY DATE TIME STAMPS FOR PROGRAM xxxxxxxx DO NOT AGREE DDIO DATE = mm/dd/yy-hh:mm:ss LOAD LIBRARY DATE = mm/dd/yy-hh:mm:ss DDIO DDNAME = dddddddd Explanation: The Reporter was unable to find a DDIO listing whose date/time stamp matches the date/time stamp of the observed program. The Reporter found a listing with the same name but a different date/time stamp. The listing was found in the DDIO file of DDNAME dddddddd. System Action: Strobe uses the listing identified in the message to generate indexing information for the measured program, but the information may be inaccurate. User Response: Ensure that all listings that match the measured programs are provided in the DDIO file referenced by the Reporter JCL. STR2160W MORE THAN 100 DDIO LISTING AND LOAD LIBRARY DATE TIME STAMPS DO NOT AGREE Explanation: Strobe has issued message STR2159I 100 times. No more STR2159I messages will be issued. System Action: The Reporter will continue trying to use the best listing available for indexing, but will no longer report mismatch errors. User Response: Ensure that all listings which match the measured modules are provided in the DDIO file referenced by the Reporter JCL. STR2161W CSS RELEASE xxxxxxxx POST-PROCESSOR LISTINGS NOT SUPPORTED WITH STROBE Explanation: Version xxxxxxxx of Compuware Shared Services (CSS) is not supported by Strobe. To get accurate indexing information from CSS DDIO files, update the version of CSS. System Action: Strobe attempts to index from the DDIO files, but the program listings used may not match the programs measured. User Response: STR2162W Request that your system administrator update to the current release of CSS. CSS RELEASE xxxxxxxx REQUIRES PTF yyyyyyyy WHEN USED WITH STROBE Explanation: Version xxxxxxxx of Compuware Shared Services (CSS) requires that PTF yyyyyyyy be applied when used with Strobe. System Action: Strobe attempts to index from the DDIO files, but the program listings used may not match the programs measured. User Response: release. STR2163E Request that your system administrator apply the required maintenance CSS MEASUREMENT/REPORTER DDF FILTER MISMATCH Explanation: You entered DDF requester report filters that do not correspond to the DDF requester parameters used for the measurement. System Action: Strobe does not process the request. User Response: Use the DDF requester report filters that match the DDF requester parameters used for the measurement. STR2164E MAX OF 2 FILTERS ALLOWED Explanation: permitted. You entered more than two DDF requester report filters. Only two filters are System Action: Strobe does not process the request. User Response: measurement. Specify filters that correspond to the DDF requester parameters used for the STR2166I INDEXING MAY BE INACCURATE Explanation: See preceding message STR2159I. Messages Produced by Strobe 3-57 System Action: Strobe uses the listing identified in the message to generate indexing information for the measured program, but the information may be inaccurate. User Response: Ensure that all listings that match the measured modules are provided in the DDIO file referenced by the Reporter JCL STR2167I INDEXING IS DISABLED FOR THIS PROGRAM Explanation: System Action: See preceding message STR2159I. Indexing is disabled for this program. User Response: Ensure that all listings that match the measured programs are provided in the DDIO file referenced by the Reporter JCL or that the DDIODATE parameter = N. STR2168I NO SOURCE FOUND IN DDIO FOR PROGRAM xxxxxxxx. INDEXING IS DISABLED FOR THIS PROGRAM Explanation: System Action: The Reporter was unable to find a DDIO listing for the observed program. Indexing is disabled for this program. User Response: Ensure that listings that match the measured programs are provided in the DDIO file referenced by the Reporter JCL. STR2191W ERROR IN WRITING SORT-OUT FILE IN P11 PASS2 Explanation: Strobe encountered an error while the internal report record from the sort was being written. System Action: incomplete. Strobe continues processing and creates a Performance Profile but it will be User Response: Notify the Strobe system programmer. STR2192E STORAGE REQUEST FAILED.TYPE=type, RC=rc, REASON=reason Explanation: A request for additional storage failed. System Action: Strobe continues processing but the information in the Performance Profile could be incomplete. User Response: STR2200W Notify the Strobe system programmer. UNDEFINED COMMAND ENCOUNTERED - COMMAND CODE=commandname Explanation: Strobe encountered an unknown command, commandname. System Action: The command does not appear on the reports. User Response: Notify the Strobe system programmer. STR2300S status {OPEN|CLOSE|READ|WRITE} ERROR ON DDNAME {SYSUT1|SYSPRINT} FILE STATUS = Explanation: The Reporter encountered an open, close, read, or write error while accessing SYSUT1 or SYSPRINT. The file status is status. If access to SYSPRINT caused the problem, the Reporter displays this message on SYSOUT. System Action: The Reporter terminates and does not produce a Performance Profile. User Response: programmer. Verify the dataset name. If the name is correct, notify the Strobe system STR2308S CANNOT DELETE XML FILE Explanation: The Reporter encountered a fatal error while attempting to delete an existing Profile dataset. The existing file was not deleted. System Action: Strobe stops processing and will not have created a profile data file. User Response: If an old XML file with the same name exists, please delete it manually and rerun Strobe Reporter. 3-58 Strobe Messages Guide STR2309S PROFILE DATASET ALREADY IN USE, TRY LATER. DATA SET IS ALLOCATED TO ANOTHER JOB OR USER. Explanation: The Reporter encountered an allocation error while attempting to delete an existing Profile dataset. The file was in use by another job or user. System Action: Strobe stops processing and will not have created a profile data file. User Response: job again. Wait until the other job or user has released the Profile dataset and try this STR2310S {ALLOCATION|UNALLOCATION} ERROR FOR {XML FILE|XML WORK FILE} REASON CODE=rsncode INFO CODE=infocode RET CODE=rc Explanation: The Reporter encountered an allocation error while attempting to create or delete either the Profile data file or a Profile data workfile for use by iStrobe. The reason code is rsncode, the information code is infocode, and the system return code is rc. System Action: Strobe stops processing and may not have created a Profile data file or a Profile data workfile. User Response: Ensure that the unit name and volume serial number specified on the Strobe - iStrobe Performance Profile Options panel is correct and resubmit the request. STR2320S {OPEN|CLOSE} ERROR ON {XML FILE|XML WORK FILE} STATUS=status Explanation: The Reporter encountered an I/O error while attempting to access a Profile data file or a Profile data workfile for use with iStrobe and shows the file status status. System Action: Strobe stops processing and may not have created a Profile data file or a Profile data workfile. User Response: If the problem is with a Profile data file, ensure that the unit name and volume serial number specified on the Strobe - iStrobe Performance Profile Options panel is correct and resubmit the request. Also verify that the unit name specified with the UI_WORKUNIT parameter in the Strobe PARMLIB member is correct. If you believe the mainframe has insufficient space for the work file, you may change the parameters for a temporary work file. To do this, see “Specifying Parameters for a Temporary Work File for iStrobe” in the Strobe User Guide. Otherwise, notify the Strobe system programmer. STR2400S UNSUCCESSFUL COMPLETION OF SORT IN modname - SORT RETURN CODE=sortrc Explanation: The installation-supplied sort/merge program named in modname did not complete execution successfully and returned a sort return code of sortrc. System Action: Strobe produces a Performance Profile but no attribution data appears in it. User Response: Review the messages produced by the sort/merge program to determine the cause of the problem. STR2401I ATTRIBUTION REPORT TOTALS WERE BELOW percent % Explanation: Execution in all modules for which Strobe normally produces Attribution reports is below the specified baseline percentage percent. System Action: Strobe produces a Performance Profile but no attribution data appears in it. User Response: To generate the Attribution reports, use the Reporter ATTR=nn.n parameter (default 2) to set the baseline percentage below that displayed in the message. STR2402W ATTRIBUTION TABLE OVERFLOW Explanation: An internal table of the Reporter program overflowed. The maximum number of Reporter-related Strobe errors that can be reported exceeded the maximum of 50. System Action: incomplete. Strobe continues processing, but data in the Attribution reports may be User Response: Notify the Strobe system programmer. STR2501I ADSO TABLE OVERFLOW Explanation: System Action: inaccurate. An internal table of the Reporter program overflowed. Strobe continues processing, but data in the ADS/O reports may be Messages Produced by Strobe User Response: STR2603I Notify the Strobe system programmer. CICS ITEMS PROCESSED..... nnn SORT RECORDS WRITTEN ..... xxx Explanation: written. System Action: User Response: STR2604I 3-59 Indicates nnn number of records processed and xxx number of sort records None required. None required. This information appears for diagnostic purposes. PERIODS......nnnn LASTPERIOD......xxxx Explanation: processed. System Action: User Response: Indicates nnnn number of periods reported and xxxx number of periods None. None required. This information appears for diagnostic purposes. STR2605W COUNTER ROLLOVER OR CICS AUTOMATIC STATISTICS IN OPERATION - VALUES OF RESET COUNTERS HAVE BEEN ESTIMATED Explanation: The CICS counters were reset to zero at least once during the session, for one of these reasons: • The CICS counters rolled over. • A user issued a reset command. This message precedes two lines of data that list the values in the counter fields at the time of the last rollover. System Action: Strobe estimates the values of the counters that have been set to zero and continues sampling. The CICS statistics in the Performance Profile may be inaccurate. User Response: Determine the interval period from the Strobe system programmer and then remeasure the region with Strobe, knowing that the CICS statistics will be reset at the end of that interval. STR2606E DATA FOR FEWER THAN 100 PERIODS RECEIVED Explanation: Fewer than 100 periods are represented in the sample dataset because the user issued a STOP, SWITCH, or QUIT command. These commands prevent Strobe from completing the measurement. You do not need to issue these commands because Strobe terminates automatically when it collects the target number of samples. System Action: The reports Strobe produces in the CICS Performance Supplement may not be statistically significant. User Response: STR2611I Rerun the measurement session and do not issue a STOP or QUIT command. SORT OUTPUT RECORDS PROCESSED nnn INTERMEDIATE RECORDS WRITTEN xxx Explanation: Indicates that nnn records were produced from the sort process and that xxx sorted records were processed. System Action: None. User Response: None required. This information is used for diagnostic purposes. STR2612E INVALID REPORT NUMBER nnn time Explanation: The Reporter encountered an invalid report number nnn at relative time time (beginning, during, or end) in the internal report file for the CICS supplement. System Action: information. Strobe will create a Profile but it will not include CICS supplement User Response: Notify the Strobe system programmer. STR2613E INVALID REPORT START nnn Explanation: The Reporter encountered an error in the internal Report file for the CICS supplement. The internal report number is nnn. System Action: Strobe will create a Performance Profile but it will not include CICS supplement information. 3-60 Strobe Messages Guide User Response: STR2614E Notify the Strobe system programmer. INVALID REPORT END nnn Explanation: The Reporter encountered an error in the internal Report file for the CICS supplement. The internal report number is nnn. System Action: Strobe will create a Performance Profile but it will not include CICS supplement information. User Response: STR2615E Notify the Strobe system programmer. INVALID XSU-RECORD-TYPE type time Explanation: The Reporter encountered an error with record type type at relative time time (beginning, during, or end) in the Transaction Usage Summary report file for the CICS supplement. System Action: Strobe will create a Performance Profile but it will not include CICS supplement information. User Response: Notify the Strobe system programmer. STR2616E INVALID DXP-RECORD-TYPE type time PERIOD xxx RESOURCE NAME name RESOURCE TYPE type BEGIN-END v Explanation: The Reporter encountered an error with record type type at time time at period xxx in resource name name with resource type type at beginning and ending at v. The error occurred while processing the Time Distribution of Transactions, Inputs, Processing and Outputs report. System Action: Strobe will create a Performance Profile but it will not include CICS supplement information. User Response: STR2617E Notify the Strobe system programmer. INVALID TRANSIENT DATA QUEUE TYPE nnnn (INITIALIZATION) Explanation: The Reporter encountered an error in the internal Report file for the CICS supplement. Transient data queue type is nnnn. System Action: Strobe will create a Performance Profile but the CICS supplement information will be incomplete. The Input - Output Activity report will not include the Number of Output Operations to Transient Data Queues section. User Response: STR2622E Notify the Strobe system programmer. INVALID REPORT NUMBER nnn Explanation: The Reporter encountered an error in the internal Report file number for the CICS supplement. The internal report number is nnn. System Action: Strobe will create a Performance Profile but the CICS supplement information will not be accurate. User Response: STR2623E Notify the Strobe system programmer. NEGATIVE DXA COUNT PERIOD =xxx VALUE = value OCCURRENCE = occurrence Explanation: The Strobe sample file contains incorrect CICS terminal message count data for recording period xxx. The VALUE value and OCCURRENCE occurrence provide internal diagnostic information. System Action: Strobe creates a Performance Profile; however, the CICS Time Distribution of Activity reports are incomplete. User Response: Save the sample file and contact the Strobe system programmer. STR2624E NEGATIVE DXS COUNT PERIOD = xxx MSG COUNT = msgcount TRANSIT SAMPLES = samples OCCURRENCE = occurrence Explanation: The Strobe sample file contains incorrect CICS transaction service time data for recording period xxx. The MSG COUNT msgcount, TRANSIT SAMPLES samples, and OCCURRENCE occurrence provide internal diagnostic information. Messages Produced by Strobe 3-61 System Action: Strobe creates a Performance Profile, however, the CICS Time Distribution of Transaction Activity reports are incomplete. User Response: STR2625E Notify the Strobe system programmer. NEGATIVE DDB COUNT PERIOD = xxx DB COUNT= dbcount OCCURRENCE = occurrence Explanation: The Strobe sample file contains incorrect CICS Data Base Access statistical data for recording period xxx. The DB COUNT dbcount and OCCURRENCE occurrence are internal diagnostic information. System Action: Strobe creates a Performance Profile; however, the CICS Time Distribution of Transaction Activity reports are incomplete. User Response: STR2626W Save the sample file and notify the Strobe system programmer. COUNTER ROLLOVER OCCURRED DURING THE MEASUREMENT SESSION Explanation: The CICS counters were reset to zero at least once during the session. This could be caused by the CICS counters rolling over (passing zero) or by a user-initiated reset command. This message precedes two lines of data that list the values in the counter fields at the time of the last rollover. System Action: Strobe estimates the values of the counters that have been set to zero and continues sampling. The CICS statistics in the Performance Profile might be inaccurate. User Response: STR2627E Save the sample dataset, and contact the Strobe system programmer. INVALID STATE, nnn Explanation: Strobe detected an error in the CICS supplement report file. nnn contains diagnostic information. System Action: information. Strobe will produce a Performance Profile, but it will not include CICS User Response: Notify the Strobe system programmer. STR2628E INVALID ITEM TYPE type Explanation: The Reporter encountered an invalid record of type type while producing the CICS supplement System Action: information. Strobe will produce a Performance Profile but it will not include CICS User Response: Notify the Strobe system programmer. STR2650W HISTOGRAM SCALE CHANGED FOR QUERY queryname [PROC procname] Explanation: Because of a table overflow error while creating the CPU Usage by SQL Statement report, Strobe encountered a Query (queryname) whose CPU usage was greater than the maximum previously calculated and printed. If the Query is part of a Procedure, then Strobe displays the Procedure name as well (procname). System Action: Strobe continues printing the report. The numerical values in the CPU usage column are correct, but the histogram may not accurately depict the CPU usage. User Response: To determine which statement consumed the most CPU time, refer to the numerical values in the CPU Usage column rather than the histogram spikes. STR2651C HEADER RECORD MISSING FOR queryname querytime Explanation: Strobe could not find the header record for Query queryname, compiled at querytime. This message can appear when you quit the measurement session, not allowing it to terminate normally. The Reporter is attempting to match attribution records with DBRM records that have not yet been written. System Action: Strobe produces the Performance Profile, but the header information for Query queryname might be incomplete. User Response: Notify the Strobe system programmer. 3-62 Strobe Messages Guide STR2652C SQL STATEMENT NUMBER EXCEEDS MAXIMUM OF 99,999,999 Explanation: The SQL statement number, derived from the program listing, exceeds Strobe’s maximum capacity of 99,999,999. System Action: Strobe produces the Performance Profile, but the CPU Usage by SQL Statement report will not be able to relate SQL statement activity to its full statement text. iStrobe will be unable to link statement activity to statement text. User Response: If possible, divide very large programs into smaller programs, so that statement numbers greater than 99,999,999 will not be generated. STR2701W libname HISTOGRAM SCALE CHANGED FOR 4GL PROGRAM NAME progname IN LIBRARY Explanation: An overflow occurred in an internal table of the Strobe Reporter program while processing data for the Natural 4GL program named progname from the library libname. System Action: Strobe continues printing the report. The numerical values in the CPU usage column are correct, but the histogram might not accurately depict the CPU usage. User Response: To determine which statement consumed the most CPU time, refer to the numerical values in the CPU Usage column rather than the histogram spikes. STR2702C FNR= fnr HEADER RECORD MISSING FOR progname LIB= libname TRANID= tranid DBID= dbid Explanation: Strobe for Adabas/Natural could not locate the header record for the Natural 4GL program progname, from the Natural program library libname, transaction ID tranid (if executed under CICS), Adabas database ID dbid (for the Natural program library), and Adabas file number fnr (for the Natural program library). System Action: Strobe produces the Performance Profile, but the header information for program progname might be incomplete. User Response: Notify the Strobe system programmer. STR2703W MAP DATA SET VERSION DOES NOT MATCH SAMPLE DATA SET VERSION OF PGM= progname LIB= libname DBID= dbid FNR= fnr Explanation: The Reporter detected a discrepancy between the map dataset and the Natural 4GL program progname, from the Natural program library libname, Adabas database ID dbid (for the Natural program library), and Adabas file number fnr (for the Natural program library). System Action: Strobe produces a Performance Profile, but it does not contain any indexing information for program progname. User Response: STR2705W Create a new map dataset and resubmit the Performance Profile request. INSUFFICIENT DATA FOR PROGRAM NAME progname Explanation: Strobe for Adabas/Natural identified Natural 4GL program progname as executing in the target address space, but it did not attribute any CPU or wait activity to that program. System Action: Strobe produces a Performance Profile, but information for the Natural program is missing. User Response: Rerun the measurement session, and specify a larger target sample size. STR2780W HISTOGRAM SCALE CHANGED FOR DL/I TRANSACTION trans MODULE modname CSECT csectname PSB psb Explanation: An internal table of the Strobe Reporter overflowed while processing data for DL/I (CPU or WAIT), transaction trans, module modname, csect csectname, PSB psb. System Action: Strobe continues printing the report. The numerical values in the CPU usage column are correct, but the histogram might not accurately depict the CPU usage. User Response: To determine which statement consumed the most CPU time, refer to the numerical values in the CPU Usage column rather than the histogram spikes. Messages Produced by Strobe 3-63 STR2781W SSA TABLE OVERFLOWED FOR TRANSACTION trans MODULE modname CSECT csectname PSB psb Explanation: An internal table of the Strobe Reporter overflowed while processing data for DL/I, transaction trans, module modname, csect csectname, PSB psb. System Action: The Reporter writes the SSA table and continues processing. User Response: Notify the Strobe system programmer. Online Reporter Messages Online Reporter Messages When executed with Strobe/ISPF, the Reporter returns the following messages. STR2811W SCREEN SIZE PARAMETER ERROR Explanation: The SCROLL keyword is missing or misspelled, or you have specified an invalid value for this screen size parameter. SCROLL must be a numeric value within the range from 24 through 99. System Action: The online Reporter uses the default value of 24 and continues execution. User Response: request. Ensure that the specified screen size parameter is correct and resubmit the STR2812E UNRECOGNIZABLE REPORT TITLE Explanation: The online Reporter encountered a Performance Profile report title that it does not recognize. System Action: Strobe stops execution and produces an incomplete Performance Profile that includes any reports generated up to the line of error. User Response: Notify the Strobe system programmer. Sample Dataset Utility Program Messages The sample dataset utility program STRBDSPY returns the following message. STR2900S status {OPEN|CLOSE|WRITE} ERROR ON DDNAME {STRSAMPL|SYSPRINT} FILE STATUS = Explanation: The Sample Dataset Utility Program encountered an open, close, or write error while accessing the sample dataset STRSAMPL or the report file SYSPRINT. The file status is status. If access to SYSPRINT caused the problem, the Reporter displays this message on SYSOUT. System Action: The Sample File Display Program terminates. User Response: programmer. Verify the dataset name. If the name is correct, notify the Strobe system Messages Returned by Strobe for CA Gen Strobe for CA Gen returns the following messages. STR2926C ACTION DIAGRAM SUMMARY REPORT EXCEEDED LIMITS Explanation: An internal table has overflowed. System Action: Strobe produces the Action Diagram Summary report; however, the information in the report is incomplete. User Response: Notify the Strobe system programmer. 3-64 Strobe Messages Guide STR2927C AD-DET-TABLE OVERFLOWED FOR ACTION DIAGRAM action diagram Explanation: The AD-DET-TABLE table overflowed. System Action: Strobe does not produce an Action Diagram Statement report for the action diagram action diagram. User Response: STR2928C Notify the Strobe system programmer. AD-STMT-TABLE OVERFLOWED FOR ACTION DIAGRAM action diagram Explanation: The AD-STMT-TABLE table overflowed. System Action: Strobe does not produce an Action Diagram Statement report for the action diagram action diagram. User Response: STR2929C Notify the Strobe system programmer. NO DIAGRAM SAMPLED OR SCHEMA RELEASE NOT SUPPORTED Explanation: Strobe for CA Gen did not identify a CA Gen, AllFusion Gen, Advantage Gen, or COOL:Gen generated module containing action diagram statements, or Strobe for CA Gen does not support the release of CA Gen, AllFusion Gen, Advantage Gen, or COOL:Gen that generated the application modules. Schema refers to an internal number that identifies the release level of the software. System Action: Strobe continues sampling but does not create reports for CA Gen. To determine the Schema Release Level number, see the SUBSYSTEM field on the Measurement Session Data report. If this field identifies a release level that Strobe for CA Gen supports, measure a program that is experiencing more activity. If this field does not reflect a schema number, then Strobe for CA Gen could not determine the release level. If there is no schema number, review the Strobe Program Usage Summary report and the Program Usage by Procedure report to see which modules Strobe identified. Contact Compuware Customer Support to resolve the problem. SQL Analysis Messages Returned by the Reporter The Reporter returns the following SQL analysis messages. STR2950S INVALID SERVICE CALL REQUEST RETURN CODE = rc Explanation: The Reporter generates this message when an invalid Strobe SQL analysis service call request is coded. The return code is rc. System Action: The Reporter produces Performance Profile data, but it does not include any SQL analysis reports. User Response: STR2951S Contact Compuware Customer Support. STRANArr MODULE NOT FOUND RET CODE = rc Explanation: The Reporter generates this message when the Strobe SQL analysis load module for DB2 release rr could not be located. The return code is rc. System Action: The Reporter produces Performance Profile data but it does not include any SQL analysis reports. User Response: STR2952E Notify the Strobe system programmer. SQL ANALYSIS FILE iotype ERROR OCCURRED Explanation: Strobe SQL analysis encountered the file error identified by iotype, which is either OPEN, READ, WRITE, or CLOSE. Processing for the current Performance Profile stops. System Action: The Reporter produces Performance Profile data, but it does not include any SQL analysis reports. User Response: If your site does not allow users to allocate temporary datasets to VIO, check that you have uncommented the allocation of the SYSTMPnn datasets and entered valid units Messages Produced by Strobe 3-65 for CLIST member Strobe and skeleton STRBPJCL. If the problem persists, contact Compuware Customer Support. STR2953E DB2 RELEASE MISMATCH. SAMPLE IS release1. DSNLOAD IS release2. SQL ANALYSIS NOT EXECUTED Explanation: The release of DB2 in the sample file release1 does not match the release of the DB2 load libraries, release2, provided to the SQL analysis component of the Reporter. System Action: Strobe generates Performance Profile data but does not produce any SQL analysis reports. User Response: Ensure that the DB2 load libraries provided for the Reporter execution are the same release as the load libraries used by the target program when the sample dataset was created. STR2966S SQLAF PROCESSING STOPPED DUE TO DB2 SYSTEM MODE. RC=xx Explanation: EXPLAIN information is not available, because of an incompatibility between the DB2 systems on which the sample dataset and the profile were created. The return code can be one of the following: 85 The sample dataset is from a DB2 subsystem running in the new function mode, but the Profile was generated from a DB2 system running in compatibility mode. These two subsystems are incompatible. 86 The sample dataset is from a DB2 subsystem running in the compatibility mode, but the Profile was generated from a DB2 system running in the new function mode. These two subsystems are incompatible. 87 The DB2 system identified by the subsystem ID in the sample dataset is running in the enabling new function mode, which is not supported. 88 The sample dataset is from a DB2 system running in the enabling new function mode, which is not supported. 89 Strobe was unable to determine the mode of the DB2 system from the subsystem ID contained in the sample dataset. System Action: Strobe produces an iStrobe profile data file, but it does not include any SQL analysis reports. User Response: STR2968S Notify the Strobe system programmer FATAL ERROR, RC=xx FROM SQLAF function Explanation: function is INIT, OPEN, CLOSE or TERM. EXPLAIN information is not available because of an internal error in Compuware’s SQLAF processor. The return code may be one of the following. 72 - An attempt to connect to DB2 failed. Typically this error is due to an invalid DB2 subsystem or the DB2 Subsystem is not active on the LPAR that the Strobe Profile job is being executed on. Verify that the SSID from the sample file or the DB2 Subsystem ID (under DB2 Subsystem Options in ISPF/iStrobe) is correct. Also, verify that the DB2 libraries accessed are compatible with the release of DB2 being used and that the LPAR that the profile job is being executed on can access that DB2 subsystem. 76 - An error occurred while attempting to CONNECT to Strobe’s DB2 Plan STRANANA. Typically, this error is due to a failure to BIND or GRANT access to STRANANA. Please ensure that installation processes STRPLBND and STRANGNT have been performed for each DB2 subsystem that Strobe will execute on. 3-66 Strobe Messages Guide 89 - An invalid SQLCODE was returned while attempting to access DB2. Typically, this code is returned when DBRM STRDNMOD has not been properly bound. Please ensure that installation process STANPBND has been executed and that the correct Collection ID has been bound into Strobe‘s plan STRANANA. System Action: Strobe produces an iStrobe profile data file, but it does not include any SQL analysis reports. User Response: Use the return code along with Strobe installation verification job SQLAFVER to try to determine your problem. If you are unable to determine the cause based on the return code, then please add //DSNTRACE DD SYSOUT=* and "PF=TRACE=31,DEBUG=4" to the parameter list and rerun the profile. Send all of the output from the SQLAFVER job and the output from the profile job with the trace specified. STR2970W STROBE SQLAF IS AVAILABLE FOR SAMPLE DATASETS 4.4 AND LATER Explanation: The Strobe sample dataset being processed by Reporter was created by a release of Strobe earlier than 4.4. System Action: SQLAF reports. The Strobe performance profile generated by Reporter will not contain the User Response: If the sample dataset being processed originated from a recently measured application, remeasure the application using a current version of Strobe in order to obtain the SQLAF reports. Messages Returned by the Strobe SQL Agent The Strobe SQL Agent enables Strobe to keep track of multi-system DB2 environments. STR3000I smid STROBE SQL AGENT READY. Explanation: Strobe SQL Agent initialization has concluded and the named agent is ready to provide services. System Action: The Strobe SQL Agent waits for an operator MODIFY command or direction from the Strobe session manager. User Response: STR3001I None required. smid STROBE SQL AGENT TERMINATION IN PROGRESS. Explanation: The internal STOP command has been accepted by the named agent. System Action: Control is given to the termination routine. This message is normally followed by message STR3003I. User Response: STR3002W None required. SQL Agent detected ******** delay, ********' Explanation: The Strobe SQL Agent is unable to contact the Strobe Session Manager. System Action: This message is repeated every 20 seconds until connection is established or 2 minutes is reached. User Response: None required unless the 2-minute threshold is reached, at which time this message will be followed by an error message. At that time, contact Compuware Customer Support. STR3003I smid STROBE SQL AGENT TERMINATION IS COMPLETE. Explanation: agent. The Strobe SQL Agent termination processing has concluded for the named System Action: Control returns to MVS. User Response: None required. Messages Produced by Strobe STR3004I 3-67 STROBE SQL AGENT OPERATING with Explanation: This message is informative only and does not require any action on the part of the user. It appears in the JES2 log of the Strobe SQL Agent (SSA) address space.  RRSAF ATTACH | CAF CONNECT These parameters indicate which DB2 connection interface is being used when the Strobe SQL Agent attaches to DB2. It is specified on the Strobe parameter DB2CONTYPE.   SQL ATTRIBUTION SAMPLING {ON | OFF} This parameter indicates whether SQL attribution sampling is enabled or disabled. It is specified on the Strobe parameter SQLATTR@SAMPLE. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3005I STRB RETRIABLE CONDITION: Condition Code / Reason Code, db2ssid Explanation: An error has occurred in the Strobe SQL Agent during startup. The instructions causing the error will be retried. See additional following messages for more detailed information. System Action: The instructions causing the error are retried. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3006W SQL Agent idle. No DB2 systems found. Explanation: The Strobe SQL Agent was unable to detect any DB2 subsystems to which it could connect. System Action: The Strobe SQL Agent remains idle. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3010I Strobe SQL agent termination - LOST SSIB. Explanation: System Action: The Strobe SQL Agent termination message. Termination processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3011I Strobe SQL agent termination - 2RM0 left. Explanation: System Action: The Strobe SQL Agent termination message. Termination processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3012I Strobe SQL agent termination - 2RMD left. Explanation: System Action: The Strobe SQL Agent termination message. Termination processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3013I Strobe SQL agent termination - SRM0 left. Explanation: System Action: The Strobe SQL Agent termination message. Termination processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3014I Strobe SQL agent termination - SRMD left. Explanation: The Strobe SQL Agent termination message. 3-68 Strobe Messages Guide System Action: Termination processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3020I Strv Strobe SQL Agent version text This message contains information about the active DB2 Subsystems detected by the Strobe SQL Agent. – Strv is the version of Strobe, usually STRB – version is the Strobe release level – text appears in the one of the following forms: 1. Checking for **** active DB2 subsystems... ****** **** Explanation: Strobe session manager detected that a DB2 system has been activated. ****** is the DB2 status. **** is the DB2 Sybsystem ID. System Action: Session manager sends a message to the Strobe SQL Agent to refresh its list of active DB2 systems. User Response: No action is required. This is an informational message. 2. Detected **** Active DB2 subsystems Explanation: Strobe SQL Agent reports the total number of active DB2 subsystems detected in the system. System Action: Strobe SQL Agent displays message STR3020I on JES2 Log. User Response: No action is required. This is an informational message. 3. to Display List, enter command /MODIFY {STRSSA},LIST Explanation: Strobe SQL Agent reports the action required to display a list of all the DB2 subsystems detected in the system. System Action: Strobe SQL Agent displays message STR3020I on JES2 Log. User Response: If the user wants to obtain a list of all the active DB2 subsystems detected by Strobe, issue the command: /MODIFY {STRSSA},LIST ir /F {STRSSA},LIST where {STRSSA} is the Strobe SQL Agent subsystem name. STR3030E smid FUNCTION ROUTINE xxxxxxxx NOT AVAILABLE. Explanation: System Action: The function routine xxxxxxxx was not found in the load library. The named Strobe SQL Agent issues user ABEND 0300 and terminates. User Response: If you are not running the Strobe SQL Agent from the target library specified at installation time, make sure that all of the modules that were installed are available in the new load library. Refer to the discussion of ABEND 0300 in “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7. Otherwise, contact Compuware Customer Support. STR3040W smid UNABLE TO OBTAIN LOCK(1). db2ssid. Explanation: The Strobe SQL Agent encountered an error while preparing to install the SQL intercept for the DB2 subsystem db2ssid. System Action: intercepted. Processing continues, but SQL for the named DB2 subsystem will not be User Response: Contact Compuware Customer Support. STR3041W smid UNABLE TO SCHEDULE. db2ssid. Explanation: The Strobe SQL Agent encountered an error while preparing to install the SQL intercept for the DB2 subsystem db2ssid. The named DB2 subsystem may have been terminating. System Action: Processing continues, but SQL for db2ssid will not be intercepted. Messages Produced by Strobe 3-69 User Response: If the named DB2 subsystem has terminated or is in the process of terminating, no response is required. Otherwise, contact Compuware Customer Support. STR3042W smid ADD FAILED. db2ssid. Explanation: The Strobe SQL Agent encountered an error while preparing to install the SQL intercept for the DB2 subsystem db2ssid. System Action: Processing continues, but SQL for db2ssid will not be intercepted. User Response: Contact Compuware Customer Support. STR3043W smid UNABLE TO OBTAIN LOCK(2). db2ssid. Explanation: The Strobe SQL Agent encountered an error while preparing to install the SQL intercept for the DB2 subsystem db2ssid. System Action: Processing continues, but SQL for db2ssid will not be intercepted. User Response: Contact Compuware Customer Support. STR3044W smid SQL INTERCEPT NOT INSTALLED. db2ssid. Explanation: The Strobe SQL Agent encountered an error while preparing to install the SQL intercept for the DB2 subsystem db2ssid. System Action: Processing continues, but SQL for db2ssid will not be intercepted. User Response: Contact Compuware Customer Support. STR3045I DB2 version 8 intercept not enabled Explanation: System Action: Strobe support for DB2 Version 8 is not enabled. Strobe Sequel Agent will not capture SQL data for DB2 version 8. User Response: For information about enabling Strobe support for DB2 version 8, contact Compuware Technical Support. STR3050E smid RECOVERY ENTERED FOR ABEND=Sxxx Uyyyy REASON=rrrrrrrr. Explanation: An ABEND was detected by the named Strobe SQL Agent. – xxx = The system ABEND code, if the ABEND was a system ABEND. – yyyy = The user ABEND code, if the ABEND was not a system ABEND. – rrrrrrrr = A reason code which gives additional information about the cause of the ABEND. If ABEND=S0000 U0300 and REASON=00040004, DB2 is not present on the MVS image but SSA=YES was specified in the Strobe parameter dataset. If no DB2 exists on this system, the parameter dataset should specify SSA=NO. System Action: Recovery processing is performed and termination of the named SSA begins. User Response: For system ABENDS, contact Compuware Customer Support. For user ABENDS, see Chapter 5, “Abend Codes Returned by Strobe” for further information about diagnosing the failure condition. STR3051E smid RECOVERY ENTERED FOR ABEND=Sxxx Uyyyy REASON CODE NOT AVAILABLE. Explanation: An ABEND was detected by the named Strobe SQL Agent. – xxx = The system ABEND code, if the ABEND was a system ABEND. – yyyy = The user ABEND code, if the ABEND was not a system ABEND. System Action: Recovery processing is performed and termination of the named SSA begins. User Response: For system ABENDS, contact Compuware Customer Support. For user ABENDS, in the Messages guide, see Chapter 5, “Abend Codes Returned by Strobe” for further information about diagnosing the failure condition. STR3052E smid PSW AT TIME OF ERROR ******** ********. Explanation: System Action: This message follows STR3050E or STR3051E and provides the error PSW. Recovery processing continues. 3-70 Strobe Messages Guide User Response: STR3060E None required. smid INVALID COMMAND IGNORED. Explanation: An operator MODIFY specified an invalid command. System Action: The operation is not performed; processing continues. User Response: Contact Compuware Customer Support. STR3061W UNSUPPORTED COMMAND. Explanation: An operator MODIFY specified an invalid command. System Action: The operation is not performed; processing continues. User Response: Contact Compuware Customer Support. STR3062I smid DB2 SSID=db2ssid, STATUS= {ACTIVE | INACTIVE}. Explanation: An operator MODIFY specified the LIST command. The Strobe SQL Agent issues this message in response to the command. db2ssid is the subsystem ID of the DB2 subsystem for which the status is being displayed. System Action: Processing continues. User Response: None required. STR3069I smid COMMAND COMPLETE. Explanation: Processing of the operator MODIFY command has completed for the named Strobe SQL Agent. System Action: Processing continues. User Response: None required. STR3100E smid RECOVERY ENTERED FOR ABEND=Sxxx Uyyyy REASON=rrrrrrrr. Explanation: An ABEND was detected by the SQL intercept for the named Strobe SQL Agent. • xxx = The system ABEND code, if the ABEND was a system ABEND. • yyyy = The user ABEND code, if the ABEND was not a system ABEND. • rrrrrrrr = A reason code which gives additional information about the cause of the ABEND. System Action: Recovery processing is performed and processing continues. User Response: For system ABENDS, contact Compuware Customer Support. For user ABENDS, in the Messages guide, see Chapter 5, “Abend Codes Returned by Strobe” for further information about diagnosing the failure condition. STR3101E smid RECOVERY ENTERED FOR ABEND=Sxxx Uyyyy REASON CODE NOT AVAILABLE. Explanation: An ABEND was detected by the SQL intercept for the named Strobe SQL Agent. • xxx = The system ABEND code, if the ABEND was a system ABEND. • yyyy = The user ABEND code, if the ABEND was not a system ABEND. System Action: Recovery processing is performed and processing continues. User Response: For system ABENDS, contact Compuware Customer Support. For user ABENDS, in the Messages guide, see Chapter 5, “Abend Codes Returned by Strobe” for further information about diagnosing the failure condition. STR3102E smid PSW AT TIME OF ERROR ******** ********. Explanation: This message follows STR3100E or STR3101E and provides the error PSW. System Action: Recovery processing continues. User Response: None required. STR3103S smid DB2 EXIT PROCESSING HAS BEEN TERMINATED. Explanation: The error count for the designated subscriber (measurement) has been exceeded. Exits will not be driven for this measurement. System Action: Processing continues but SQL reporting will be degraded. Messages Produced by Strobe User Response: STR3104E 3-71 Contact Compuware Customer Support. smid ******** ******** ******** ********. Explanation: System Action: This message follows STR3102E and provides register content. Recovery processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3111E smid.routine text Explanation: An internal processing error has occurred in source module routine smid.routine and is described in text: • • • • • • • • PrIf2000 Fif* Attach failed MainLoop Previous XmPost failed MainCkAct bad IftTyp PrIi $TRC Init failed PrIi FIFM Init failed PrIfIn Fif* Duplicate subtask PrIf2000 Fif* Attach macro failed' PrIf2000 Fif* Attach failed' System Action: The measurement task terminates. User Response: Contact Compuware Customer Support. STR3120I smid.routine text Explanation: This is an informational message, described in text, that Compuware Customer Support can use to determine the status of a measurement in the event of a problem: STR3120I STR3120I STR3120I STR3120I STR3120I STR3120I STR3120I STR3120I STR3120I STR3120I STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: STRBFIFM: System Action: None. User Response: None. STR3121E Command STAM received , PTF XXXXXX Command STAM completed Command FLSH received Command FLSH completed Command FLSHE received Command FLSHE completed Command MAKZ received Command MAKZ completed SQL Activity Acknowledged Buffer Re-positioned STRBFIFM: text Explanation: This message contains information related to processing DB2 trace records. The text appears in one of the following forms: STR3121E STRBFIFM. *** The DBRM (STRDFIFM) for Strobe's SSA has not been bound for this Version. Generic Text will be provided for all Static SQL. Please execute bind. Explanation: This is typically caused by a failure to bind the DBRM STRDFIFM into Strobe’s plan STRANANA or the DBRM was bound, but the collection that it was bound into was not added to the PKLIST when the plan STRANANA was bound. System Action: The measurement continues, but no SQL text is available for any Static SQL. User Response: Please ensure that install processes STRBPBND and STRPLBND, found in the SSTRSAMP library, have been executed for each DB2 subsystem that will have Strobe measurements. The SQLAFVER process, in the Strobe SSTRSAMP library, can be used to help determine what binds need to be executed. For further assistance, contact Compuware Customer Support. STR3121E STRBFIFM. *** Strobe's SSA was unable to connect to DB2. Generic text will be provided for Static SQL. Please review Strobe Installation Instructions. Explanation: STRANANA. This is typically caused by a failure to grant public access to Strobe's plan 3-72 Strobe Messages Guide System Action: The measurement continues, but no SQL text is available for any Static SQL. User Response: Please ensure that install process STRANGNT, found in the SSTRSAMP library, has been executed for each DB2 subsystem that will have Strobe measurements. The SQLAFVER process, in the Strobe SSTRSAMP library, can be used to help determine what grants need to be executed. For further assistance, contact Compuware Customer Support. STR3121E smid.routine text Explanation: An internal processing error has occurred in source module routine smid.routine and is described in text: • • • • • • • • • • • • xxxxxxxx Storage Obtain Failed Invalid Return - LOCATE_QIT Invalid Return - LOCATE_QIT_ENTRY Invalid Return - PUT_STS_TEXT Entry Not Found on Stack Dataspace Allocation Error, SSA Bypassed No DBRM CPOOL Cell Returned No STMT CPOOL Cell Returned No TEXT CPOOL Cell Returned *** Unable to allocate storage. Please submit fewer concurrent measurements. *** Time Limit on Final Flush Exceeded. Intermediate Results will be provided. Trace Buffers are No Longer Accessible System Action: The named Strobe SQL Agent issues user abend U500 and terminates. User Response: Contact Compuware Customer Support. STR3122W smid.text Explanation: The Strobe Agent has encountered an unexpected situation in source module smid. It issues a warning message and attempts to continue. One of the following messages appears in text: • • • • • • • • • • • • • • • • • • Unable to Access SMO for Zxx Record Unable to Write Zxx Record to SDS Trigger Begin Missed Stored Procedure Begin Missed No Beginning Statement Found for End routine SQL Text Truncated to Max Allowed Load of DSNRLI Failed Load of DSNHLI2 Failed RRSAF IDENTIFY Failed RSAF SIGNON Failed CREATE THREAD Failed RRSAF Terminate Failed routine Select Failed, SQLCODE: XXX routine Open Failed, SQLCODE: XXX routine Fetch Failed, SQLCODE: XXX routine Close Failed, SQLCODE: XXX routine Repeat SMO Extension Request Trace Data Lost SSA Processing Suspended System Action: Processing continues, but generic text may be substituted for actual SQL. User Response: Contact Compuware Customer Support. STR3150E STRBGBES Stimerm Set failed Explanation: An internal timer to protect against excessive elapsed time for Strobe SQL Agent (SSA) requests has failed. System Action: Processing continues without time-out protection. User Response: If the message persists, contact Compuware Customer Support. STR3151E STRBGBES Stimerm Cancel failed Explanation: The cancellation of an internal timer to protect against excessive elapsed time for Strobe SQL Agent (SSA) requests has failed. System Action: Processing continues. Messages Produced by Strobe User Response: STR3152E 3-73 If the message persists, contact Compuware Customer Support. STRBGBES Stimerm exit SSA request timeout, abending request Explanation: A request for Strobe SQL Agent (SSA) services has taken more than 5 minutes to complete. System Action: The measurement task stops sampling and terminates with a user ABEND code of 522. The Measurement Session Data report will be incomplete. User Response: STR3200E Contact Compuware Customer Support. STRBFIFR: Unable to obtain buffer for IFI commands Explanation: Strobe DB2 IFCID Trace Collector was unable to obtain storage for the IFI command buffer. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'04'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3201I STRBFIFR: Unable to start internal trace. Explanation: Strobe DB2 IFCID Trace Collector was unable to start the internal trace. System Action: The Strobe DB2 IFCID Trace Collector internal trace will be inactive. User Response: No action is required. This is an informational message. STR3202E STRBFIFR: Running from a non-APF library. Explanation: Strobe DB2 IFCID Trace Collector has been attached from a non-APF authorized library. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'10'. See “Abend Codes Returned by Strobe” on page 5-1 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3203E STRBFIFR: Invalid SQL agent environment detected Explanation: Strobe DB2 IFCID Trace Collector was unable to find one or more runtime Strobe internal Control Blocks. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'08'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3204E STRBFIFR: Unable to load IFI parameters module. Explanation: Strobe DB2 IFCID Trace Collector was unable to load the IFI parameters module STRBFIFP. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'0C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3205E STRBFIFR: Unable to obtain storage for IFI buffer prefixes. Explanation: Strobe DB2 IFCID Trace Collector was unable to obtain storage for the IFI buffer prefixes. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'14'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. 3-74 Strobe Messages Guide User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3206E STRBFIFR: Unable to obtain storage for IFI buffers. Explanation: buffers. Strobe DB2 IFCID Trace Collector was unable to obtain storage for the IFI System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'18'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3207E STRBFIFR: Unable to initialize IFI environment. Explanation: Strobe DB2 IFCID Trace Collector was unable to connect to the DB2 subsystem where the measured application is running. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3208E STRBFIFR: Unsupported DB2 version. Explanation: Strobe DB2 IFCID Trace Collector detected an invalid DB2 Version on the DB2 Trace Anchor Block. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'20'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3209E STRBFIFR: Unable to format start trace command Explanation: Strobe DB2 IFCID Trace Collector was unable to format the DB2 start performance trace command. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'24'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3210E STRBFIFR: Unable to start performance trace. Explanation: trace. Strobe DB2 IFCID Trace Collector was unable to start the DB2 performance System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'28'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3211I STRBFIFR: Initialization complete - Id=9999 Explanation: Strobe DB2 IFCID Trace Collector has established the DB2 IFI collection environment successfully. Id=9999 uniquely identifies the IFI Collector. System Action: None. User Response: No action is required. This is an informational message. STR3212E STRBFIFR: Unable to start internal timer. Explanation: Strobe DB2 IFCID Trace Collector was unable to start its internal timer. Messages Produced by Strobe 3-75 System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'30'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3213I STRBFIFR: Maximum idle time reached, subtask shutting down. Explanation: allowed. Strobe DB2 IFCID Trace Collector idle time reached the maximum idle time System Action: The Strobe DB2 IFCID Trace Collector subtask is terminated if the maximum idle time is reached and no measurement collection request is in progress. User Response: STR3214I No action is required. This is an informational message. STRBFIFR: Shutdown in progress, DB2 terminated. Explanation: Strobe DB2 IFCID Trace Collector has been posted by DB2 subsystem indicating that DB2 is terminating. System Action: The Strobe DB2 IFCID Trace Collector subtask is terminated, and any IFI collection in progress is aborted. User Response: STR3215E No action is required. This is an informational message. STRBFIFR: IFI Collector Id=9999 ran out of buffers(1111/2222/3333) Explanation: Strobe DB2 IFCID Trace Collector, identified by Id=9999, has run out of buffers to collect the IFCIDS generated by DB2, where: • 1111 = Number of buffers ready to reuse • 2222 = Number of buffers busy with one reader • 3333 = Number of buffers with more than one reader. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'44'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3216I STRBFIFR: IFI EXRACO Enqueued buffer (NNNN) to inprocess Q Explanation: Strobe DB2 IFCID Trace Collector internal routine EXRACO has enqueued buffer NNNN to the in-process buffer queue. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required, this is an informational message. STR3217E STRBFIFR: IFI GTBUIP Unable to obtain inprocess queue lock Explanation: Strobe DB2 IFCID Trace Collector internal routine GTBUIP was unable to obtain a lock on the in-process buffer queue in order to return processed buffers to available buffer queue. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'58'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3218E STRBFIFR: IFI PTBUIP Unable to obtain inprocess queue lock Explanation: Strobe DB2 IFCID Trace Collector internal routine PTBUIP unable to obtain a lock on the in-process buffer queue in order to add a buffer to the queue. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'54'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. 3-76 Strobe Messages Guide STR3219E STRBFIFR: IFI Collector experiencing shortage of trace buffers Explanation: Strobe DB2 IFCID Trace Collector has been unable to return buffers from the in-process buffer queue to the available queue, and the available buffer queue is empty. System Action: Strobe DB2 IFCID Trace Collector will enter a wait for the number of times specified in BUFFER_SHORTAGE_LOOP. If the wait time specified expires, the Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'44'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3220I STRBFIFR: IFI Collector pausing IFCID collection - Id=9999 Explanation: Strobe DB2 IFCID Trace Collector, identified by Id=9999, has entered in a WAIT loop attempting to recover from a shortage of buffers. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3221I STRBFIFR: IFI CKIPQU Enqueued buffer (NNNN) to available Q Explanation: Strobe DB2 IFCID Trace Collector internal routine CKIPQU has enqueued buffer NNNN to the available buffer queue. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3222E STRBFIFR: *** Error, load of DSNRLI/DSNALI failed *** Explanation: Strobe DB2 IFCID Trace Collector invoked an MVS service to load the DB2 Attach stub, but the load request failed. System Action: Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, return code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3223E STRBFIFR: *** Error, load of DSNWLIR/DSNWLI2 failed *** Explanation: Strobe DB2 IFCID Trace Collector invoked an MVS service to load the DB2 IFI Interface stub, but the load request failed. System Action: Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, return code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard and notify the Strobe system programmer. STR3224E STRBFIFR: not using IFI interface Explanation: The authorization ID associated with this connection is not authorized to use the specified plan name or the specified plan name does not exist. Another possible cause is that the allocation of the plan to the connection failed. Either a resource is unavailable or the requested resource (plan) is not known DB2. System Action: Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, return code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3225E STRBFIFR: PlanName=PPPPPPPP, DB2Id=DDDD Explanation: The release of the DB2 Attachment Stub and the DB2 subsystem do not match, but are compatible to make the connection. Messages Produced by Strobe 3-77 System Action: Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, return code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3226I STRBFIFR: DDDD IFI connection established Explanation: Strobe DB2 IFCID Trace Collector has established an IFI connection to DB2 DDDD using an XXXXX attachment. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3227I STRBFIFR: DDDD IFI connection terminated Explanation: Strobe DB2 IFCID Trace Collector has terminated an IFI connection to DB2 DDDD using an XXXXX attachment. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required, this is an informational message. STR3228E STRBFIFR: Unable to locate XXXX Strobe control block Explanation: Strobe DB2 IFCID Trace Collector internal routine GTSTCB was unable to locate the XXXX Strobe Control Block. System Action: Strobe DB2 IFCID Trace Collector will issue the message STR3203, and the Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'08'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3229I STRBFIFR: Buffer too small to hold READS data(00E60815) Explanation: Buffer provided by the Strobe DB2 IFCID Trace Collector to DB2 was not large enough to accommodate all the IFCIDS returned by DB2 for READS command. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Allocate more storage for the return area, if possible. STR3230I STRBFIFR: No data was returned for requested command(00E60804) Explanation: No data was returned from the READS or READA request. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3231I STRBFIFR: MONITOR1 auth required, no data can be collected Explanation: An authorization failure occurred. On a READA request, the ownership token specified did not match the owner of an active trace, or on either a READA or READS request, the user did not have the correct monitor authority. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'50'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3232I STRBFIFR: Multiple attempts of READS failed, READS abandoned Explanation: Strobe DB2 IFCID Trace Collector reached the maximum limit of retries for a READS command. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'60'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. 3-78 Strobe Messages Guide User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3233I STRBFIFR: IFI monitor trace is no longer active Explanation: Strobe DB2 IFCID Trace Collector is no longer connected to this instance of the DB2 subsystem. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'44'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3234I EXIFRA READA failed: RC=00000008,RSN=xxxxxxxx Explanation: Internal IFI READA DB2 command, issued by the Strobe DB2 IFCID Trace Collector, failed with the return code (RC) and reason code (RSN) shown in the message. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Check DB2 message DSN1720I READA ERROR, REASON=xxxxxxxx for a complete explanation of possible values for the reason code. STR3235I STRBFIFR: Buffer too small to hold READA data(00E60815) Explanation: Buffer provided by the Strobe DB2 IFCID Trace Collector to DB2 was not large enough to accommodate all the IFCIDs returned by DB2 for a READA command. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Allocate more storage for the return area, if desired. STR3236I STRBFIFR: Multiple attempts of READA failed, READA abandoned Explanation: Strobe DB2 IFCID Trace Collector reached the maximum limit of retries for a READA command. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'44'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3237I STRBFIFR: Unable to obtain buffer for IFICID 106 Explanation: 105 buffer. Strobe DB2 IFCID Trace Collector was unable to obtain storage for the IFICID System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Allocate more storage for the return area, if possible. STR3238I STRBFIFR: ******* trace already active for DB2 #### Explanation: Strobe DB2 IFCID Trace Collector has been requested to initiate a new Local/DDF collector for DB2 ####, but a Local/DDF collection is already active. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3239I STRBFIFR: IFI collector dispatching priority lower than DB2; data might be lost Explanation: Strobe DB2 IFCID Trace Collector has detected that its dispatching priority is lower than the DB2 dispatching priority, which might lead the collector to miss data. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Assign the Strobe DB2 IFCID Trace Collector the same or higher priority than the DB2 MSTR Address Space. Messages Produced by Strobe STR3240I 3-79 STRBFIFR: IFI EXRACO Detected no reader for buffer(NNN) Explanation: Strobe DB2 IFCID Trace Collector internal routine EXRACO has been posted by DB2 with a complete buffer, but there is no measurement active to be posted. Buffer is ignored. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: No action is required. This is an informational message. STR3241I STRBFIFR: Buffer too small to hold READA data(00E60815-RC=4) Explanation: Buffer provided by the Strobe DB2 IFCID Trace Collector to DB2 was not large enough to accommodate all the IFCIDS returned by DB2 for a READA command. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. User Response: Allocate more storage for the return area, if desired. STR3242E STRBFIFR: RRS not active, SQL capture is terminated. Explanation: Strobe DB2 IFCID Trace Collector has detected that the RRS ATTACH is not active on this z/OS image. System Action: The Strobe DB2 IFCID Trace Collector is terminated with ABEND U400, reason code=x'1C'. See “ABEND Codes Returned by the Strobe SQL Agent” on page 5-7 for reason code explanation. User Response: Process the dump according to your installation’s standard, and notify the Strobe system programmer. STR3243I STRBFIFR: Starting as a fffffffff Collector for DB2 #### Explanation: Strobe SQL Agent is starting a SQL capture on DB2 SSID ####. The type of trace ffffffff is either “Filtering” or “non-Filtering”. System Action: The Strobe measurement continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3244I STRBFIFR: Collecting IFCIDS for Request: ####, Jobname: jjjjjjjj Explanation: jjjjjjjj. System Action: Strobe SQL Agent is starting a filtered SQL capture, request ####, on Jobname The Strobe measurement continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR3245I STRBFIFR: ****************** Explanation: Strobe SQL Agent has received a DB2 command failure. The applicable Strobe Error Message will follow one or more of these STR3245I messages. The DB2 messages with the reason for the failure will be shown in these STR3245I messages. System Action: attribution. The Strobe measurement may terminate or continue without SQL User Response: Contact Compuware Customer Support. STR3246I STRBFIFR: {text} Explanation: This message contains information related to processing DB2 trace records. The text appears in one of the following forms: STR3246I STRBFIFR: Strobe module STRBFIFR V- Explanation: This message indicates the version of the STRBFIFR Strobe module along with its PTF level, compile date and time. System Action: None. User Response: No action is required. This is an informational message. 3-80 Strobe Messages Guide STR3246I STRBFIFR: DB2 trace started Explanation: Accounting. A Strobe DB2 IFCID trace was started of the following type: Performance or System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: DB2 OPx Buffer size in effect: {MBytes|KBytes} Explanation: This message indicates the size of the IFI online performance (OPx) buffer used as the destination for trace records. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Total HV Common Storage ... MBytes Explanation: This message indicates the total storage (in megabytes) that is either allocated or available in high virtual common area storage. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Using % free storage for IFI buffers Explanation: This message indicates the free storage method is being used to allocate IFI online performance (OPx) buffers and the percentage that is used in calculating the amount. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Free storage above the line ... Explanation: This message indicates the free storage method is being used to allocate IFI online performance (OPx) buffers and the total amount of free virtual storage that is currently available above the 16MB line. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Number of IFI buffers ... Explanation: This message indicates the total number of IFI online performance (OPx) buffers (in hexadecimal) used for trace records. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Size of each IFI buffer ... Explanation: This message indicates the size of each IFI online performance (OPx) buffer (in hexadecimal) used for trace records. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Total storage for IFI buffers ... Explanation: This message indicates the total amount of virtual storage allocated for IFI online performance (OPx) buffers (in hexadecimal) that is used for trace records. System Action: Strobe continues processing. User Response: No action is required. This is an informational message. STR3246I STRBFIFR: Constraint list unavailable. IFI Collection cannot start Explanation: An error occurred that prevents a trace constraint list from being built. A Strobe DB2 IFCID trace could not be started. Messages Produced by Strobe 3-81 System Action: Strobe continues processing, but SQL information for the named DB2 subsystem will not be intercepted. User Response: STR3246I Contact Compuware Customer Support. STRBFIFR: IFI Collector entering special read mode. Explanation: The Strobe DB2 IFCID Trace Collector has encountered a situation where OPx buffer storage was exhausted, possibly causing loss of some trace record data. System Action: Strobe continues processing. An attempt will be made to read and clear the contents of the buffer to allow trace record processing to continue. Some SQL information may be lost. User Response: For unfiltered measurements, specify DB2 Trace Filter options to limit the amount of trace information collected using the IBM DB2 Instrumentation Facility Interface (IFI). Consider increasing the dispatching priority of the Strobe SQL Agent (SSA) address space to help prevent loss of trace record data. If the condition persists, contact Compuware Customer Support. STR3246I STRBFIFR: IFI Collector exiting special read mode . Explanation: The Strobe DB2 IFCID Trace Collector encountered a situation where OPx buffer storage was exhausted. An attempt was made to allow trace record processing to continue, which was either a failure or a success, as indicated by this message. System Action: Strobe continues processing. Some SQL information may be lost. User Response: For unfiltered measurements, specify DB2 Trace Filter options to limit the amount of trace information collected using the IBM DB2 Instrumentation Facility Interface (IFI). Consider increasing the dispatching priority of the Strobe SQL Agent (SSA) address space to help prevent loss of trace record data. If the condition persists, contact Compuware Customer Support. STR3246I STRBFIFR: *** Invalid OPx received from SSID=DB2ssid possible causes are: - Max# of DB2 Traces Active reached  - Insufficient DB2 Access Authority Explanation: A Strobe DB2 IFCID trace could not be started. This is usually because an OPx destination buffer was unavailable. Each DB2 subsystem only supports up to eight concurrent OPx traces. Additionally, the Strobe SQL Agent (SSA) address space must be in possession of the proper set of privileges to issue the -START TRACE command on the DB2 subsystem. These privileges must be granted on each DB2 subsystem where there are DB2 applications or DDF address spaces that Strobe will be measuring. System Action: Strobe continues processing, but SQL information for the named DB2 subsystem will not be intercepted. User Response: Please ensure that install process STRBGRNT, found in the SSTRSAMP library, has been executed for each DB2 subsystem that will have Strobe measurements. The SQLAFVER process, found in the Strobe SSTRSAMP library, can be used to help determine what grants need to be executed. Verify with your security administrator (RACF, Top Secret) to verify that there is a valid user ID created for Strobe SQL Agent authorization ID. For multiple concurrent Strobe DB2 measurements, consider using unfiltered DB2 options to reduce the number of active IFCID traces. If the condition persists, contact Compuware Customer Support. STR3247E STRBFIFR: -STA TRA (PERF) command failed (timeout), shutdown in progress Explanation: A DB2 -START TRACE (PERFORMANCE) request issued by the Strobe IFI Collector (STRBFIFR) has taken more than 1 minute to complete. System Action: The Strobe SQL Attributor (STRBDSNA) issues message STR8710E, and the measurement task stops sampling and terminates immediately. The Measurement Session Data report will be incomplete. User Response: Check the DB2 MSTR and IRLM Address Space logs for messages related to locks/timeouts associated with the DB2 TRACE component. STR3248I STRBFIFR: IFI Collector resuming IFCID collection - Id=9999 Explanation: Strobe DB2 IFCID Trace Collector, identified by Id=9999, is resuming the IFCID Collection after the WAIT loop attempting to recover from a shortage of buffers. System Action: The Strobe DB2 IFCID Trace Collector subtask continues processing. 3-82 Strobe Messages Guide User Response: STR3249I No action is required. This is an informational message. STRBFIFC: DB2 Accounting rollup: ACCUMACC=##,ACCUMUID=## Explanation: This is an informational message issued by the Strobe IFI Accounting Collector module to display the current values of DB2 parameters ACCUMAC and ACCUMUID. These parameters are used by DB2 to control the DB2 Accounting data generation for DDF/RRSAF. This message is intended to provide information for problem resolution by Compuware Customer Support. For an explanation of the possible values for ACCUMAC and ACCUMUID, see IBM’s DB2 for z/OS Installation and Migration Guide (GC19-2974-03). System Action: IFI Collections Processing continues. User Response: None required. Messages Returned by Data Collectors Data collector programs return the following messages. STR4010I STR5 STROBE SQL AGENT TERMINATION - 2RM0 LEFT Explanation: The Strobe SQL agent issued this message at the final stage of termination. System Action: Normal termination continues. User Response: No action is required. This is an informational message. STR4010I STR5 STROBE SQL AGENT TERMINATION - 2RMD LEFT Explanation: The Strobe SQL agent issued this message at the final stage of termination. System Action: Normal termination continues. User Response: No action is required. This is an informational message. STR4030I STR5 STROBE SQL AGENT TERMINATION - SRM0 LEFT Explanation: The Strobe SQL agent issued this message at the final stage of termination. System Action: Normal termination continues. User Response: No action is required. This is an informational message. STR4040I STR5 STROBE SQL AGENT TERMINATION - SRMD LEFT Explanation: The Strobe SQL agent issued this message at the final stage of termination. System Action: Normal termination continues. User Response: No action is required. This is an informational message. STR4110E GETMAIN FAILURE - CICS DATA COLLECTOR DISABLED Explanation: A GETMAIN failure occurred when the CICS data collector was trying to obtain virtual storage for its work area. You can produce a Performance Profile without the CICS Performance Supplement. System Action: Strobe continues sampling without the CICS data collector. User Response: Notify the Strobe system programmer. STR4114E subsys RELEASE NOT SUPPORTED Explanation: Strobe does not support the version of the measured subsystem subsys. System Action: Strobe continues sampling without the data collector for that subsystem. Attribution reports for the named subsystem will be incomplete. User Response: STR4116E Notify the Strobe system programmer. CICS MODULE IDENTIFICATION SERVICE NOT INITIALIZED Explanation: System Action: Strobe was unable to initialize the CICS data collector. Strobe continues sampling without the CICS data collector. Messages Produced by Strobe User Response: STR4118E Notify the Strobe system programmer. LOAD OF modname FAILED - CICS DATA COLLECTOR DISABLED Explanation: modname. Strobe could not invoke Strobe for CICS because it could not find the module System Action: Strobe continues sampling without the CICS data collector. User Response: Notify the Strobe system programmer. STR4120E 3-83 GETMAIN FAILURE - modname DISABLED Explanation: A GETMAIN failure occurred when the modname tried to obtain virtual storage for its work area. System Action: Strobe continues sampling, but the reports in the CICS Performance Supplement might be incomplete. User Response: STR4121E Notify the Strobe system programmer. FREEMAIN failure - xxxxxxxxxxxxxxxxx Explanation: Strobe transaction profiling was terminating andattempted to RELEASE the storage listed. One or two of these will not cause a problem but if it persists do not submit any more measurements for the current JOB. System Action: Strobe continues measurement termination with storage not released. User Response: Contact Compuware Technical Support. STR4122E ABEND THRESHOLD EXCEEDED - modname DISABLED Explanation: The CICS data collector encountered a severe error in modname. System Action: Strobe continues sampling, but the reports in the CICS Performance Supplement may be incomplete. User Response: STR4123W Notify the Strobe system programmer. DFHxxxx copy storage left behind Explanation: Strobe transaction profiling was terminating and could not RELEASE the storage listed because it was still in use. Subsequent measurements will not include some or all of the transaction service times. System Action: Strobe continues measurement termination with storage not released. User Response: Contact Compuware Technical Support. STR4124E DISABLED modname DETECTED CORRUPTION OF STROBE FOR CICS CONTROL BLOCK - MODULE Explanation: Control section modname detected a storage corruption problem within Strobemanaged storage. System Action: Strobe continues sampling without the CICS data collector. User Response: Notify the Strobe system programmer. STR4125E modname DISABLED - INITIALIZATION INCOMPLETE Explanation: Strobe module modname failed to properly initialize itself at the start of a Strobe measurement session. System Action: The services provided by modname will not be available during the measurement session. Strobe for CICS will continue collecting data, but the data will be incomplete. User Response: STR4126E Notify the Strobe system programmer. DBCTL DATA COLLECTION DISABLED Explanation: System Action: A severe error occurred in the CICS DBCTL data collector. Strobe continues sampling without the CICS DBCTL data collector. 3-84 Strobe Messages Guide User Response: Examine the log for previously issued messages to determine why the CICS DBCTL data collector failed. STR4128I DBCTL CONNECTION NOT ACTIVE; DBCTL DATA COLLECTOR QUIESCED Explanation: An active CICS/DBCTL connection was not present when the Strobe measurement session began. System Action: Strobe continues sampling without the CICS DBCTL data collector. The Performance Profile will not contain any DBCTL-specific information. User Response: Ensure that the CICS/DBCTL connection is active before you begin a measurement request. If not, use the CICS transaction CDBC to activate it. Once the connection is active, resubmit the measurement request. STR4130E INVALID INPUT - modname Explanation: A Strobe driver invoked the Strobe module modname with an invalid parameter. System Action: Strobe continues sampling; Strobe for CICS is not disabled. User Response: Notify the Strobe system programmer. STR4131I modname - PLACED OUT OF SERVICE Explanation: Strobe for CICS disabled Strobe module modname. System Action: Strobe continues sampling, however Strobe for CICS attribution and module identification functions are disabled. User Response: Notify the Strobe system programmer. STR4210W SAMPLING TERMINATED BEFORE LIMIT REACHED - CICS SUPPLEMENT WILL BE INCOMPLETE Explanation: The measurement session terminated before reaching the target sample size because the user directed it to do so. System Action: Strobe produces the Performance Profile, but the CICS Performance Supplement is incomplete. User Response: Resubmit the measurement request, specifying LIMIT=QUIT. Strobe terminates the request when it reaches the target number of samples. STR4211E GETMAIN FAILURE IN csectname - CICS STATISTICS NOT PRODUCED Explanation: A GETMAIN failure occurred when the CICS data collector in the control section csectname was trying to obtain virtual storage for a work area. System Action: Strobe continues sampling but the CICS Performance Supplement reports are missing from the Performance Profile. User Response: STR4212E Notify the Strobe system programmer. STROBE STARTED DURING CICS INITIALIZATION - CICS STATISTICS NOT PRODUCED Explanation: Strobe started sampling while CICS was being initialized. System Action: Strobe continues sampling, but the CICS Performance Supplement reports are missing from the Performance Profile. User Response: STR4213E Resubmit the job after CICS is initialized. CICS TERMINATING WHILE SAMPLING - STATISTICS NOT PRODUCED Explanation: CICS terminated while Strobe was sampling. System Action: Strobe continues sampling, but the reports in the CICS Performance Supplement could be incomplete. User Response: None required. STR4214E ABEND IN CPS DATA COLLECTOR - CICS PERFORMANCE SUPPLEMENT WILL BE INCOMPLETE Explanation: Strobe encountered an ABEND while gathering statistics for the CICS Performance Supplement. Messages Produced by Strobe 3-85 System Action: Strobe continues sampling, but the reports in the CICS Performance Supplement will be incomplete. User Response: STR4215W Notify the Strobe system programmer. TRANSACTION PROFILING NOT SUPPORTED FOR RELEASE x.x Explanation: Strobe for CICS detected an unsupported release of CICS, xx. Strobe cannot collect the performance information for the Transaction Profile. System Action: Strobe continues processing, but does not collect performance information for the CICS Transaction Profile. User Response: Verify that the environment is CICS Transaction Server Version 1.3 or greater. STR4216W PROFILED TRANSACTION tran MAY BE A SYSTEM TRANSACTION, WHICH MAY NOT BE Explanation: You requested detailed performance information for the transaction tran and used a wildcard (*). However, the name of the transaction you specified could conflict with the names of existing CICS system transactions. System Action: Strobe continues processing. If the transaction is a CICS transaction, Strobe will not supply detailed performance information for the transaction. User Response: IBM transactions begin with the letter C. To reduce potential conflicts with system transactions, user transactions starting with C should be fully qualified. Do not use a wildcard (*). STR4217E LOAD OF modname FAILED - TRANSACTION PROFILING DISABLED Explanation: Strobe for CICS could not provide detailed performance information for transactions because it could not locate the module modname. System Action: Strobe continues sampling, but does not gather detailed performance information for CICS transactions. User Response: Notify the Strobe programmer. STR4218E CICS TRANSACTION PROFILING DATASPACE dataspace-id FULL CONDITION AT SAMPLE sample Explanation: Dataspace dataspace-id, used to collect detailed performance information, failed because it encountered a full condition at sample. The dataspace identification numbers relate to these dataspaces: Dataspace ID Dataspace 01 Service Time Dataspace 02 Transaction Profile Dataspace 03 Non-transaction Profile Dataspace 04 Region Level Dataspace System Action: Strobe continues processing, but cannot collect performance information for the CICS Transaction Profile. User Response: Increase the size of the dataspace with the CICS=DSSIZE parameter. See the Strobe for CICS manual for more information. STR4219E TRANSACTION PROFILING GETMAIN BUFFER FAILURE -- reason Explanation: Strobe was unable to obtain the required buffer area to gather detailed performance information for CICS transactions. There is not enough available virtual storage to satisfy requirements for the Transaction Queue Scan Buffer or the Bridge Transaction Buffer because of reason. System Action: Strobe continues processing, but is unable to collect performance information for the CICS Transaction Profile. User Response: Specify a larger region size. 3-86 Strobe Messages Guide STR4220W TRANSACTION tran IS A SYSTEM TRANSACTION AND CANNOT BE PROFILED Explanation: The CICS transaction tran you specified when you submitted the measurement request is a CICS system transaction. System Action: Strobe continues processing, but does not gather detailed performance information for the transaction tran. User Response: Enter only user transactions, not CICS system transactions, into the transaction detail list. STR4221E CICS TRANSACTION PROFILING DISABLED Explanation: Strobe cannot collect performance information for the Transaction Profile because it encountered a severe error. System Action: Strobe continues processing without collecting detailed performance information for the transaction. User Response: response. Review the error messages in the Strobe log and follow the recommended STR4224E UNABLE TO PLACE CICS SERVICE TIME CAPTURE, RETURN CODE  FROM STRBGMIM = rc Explanation: Strobe for CICS received a non-zero return code rc from STRBGMIM, indicating an error condition. System Action: Strobe continues processing, but cannot collect performance information for the CICS Transaction Profile. User Response: STR4225E Contact Compuware Customer Support. CICS SERVICE TIME CAPTURE DISABLED Explanation: The CICS service time capture experienced a severe error. System Action: Strobe continues processing but cannot collect performance information for the Transaction Profile. The transactions counts and service times in the CICS Transaction Profile Report are inaccurate. User Response: STR4227E Notify the Strobe programmer. modname INTERNAL ERROR-reason-code Explanation: A Strobe for CICS module, modname, experienced a severe internal error. System Action: Strobe continues processing, but cannot collect performance information for the Transaction Profile. Strobe produces CICS Transaction Profiling Reports, but the counts and service times are inaccurate. User Response: STR4228E Notify the Strobe system programmer. CICS DFHxxxx module not found Explanation: Strobe transaction profiling was attempting to implant the intercept at the module listed but could not identify it. System Action: Transaction profiling will continue with some information missing or terminate depending on the module listed. User Response: STR4229E Contact Compuware Technical Support. UNEXPECTED MODULE HEADER LENGTH ENCOUNTERED Explanation: Strobe for CICS encountered an unexpected length in the module header for the CICS service time exit module. System Action: Strobe continues processing, but does not collect performance information for the Transaction Profile. User Response: Contact Compuware Customer Support. Messages Produced by Strobe STR4230E 3-87 ERROR IN DATASPACE API FUNCTION function DATASPACE dataspace-id RC return code Explanation: Strobe for CICS encountered an error when issuing a call for function function dataspace dataspace-id to the Strobe dataspace API. The dataspace-ids are: Dataspace ID Dataspace 01 Service Time Dataspace 02 Transaction Profile Dataspace 03 Non-transaction Profile Dataspace 04 Region Level Dataspace System Action: Strobe continues processing, but cannot collect performance information for the CICS Transaction Profile. Strobe produces the CICS Transaction Profile reports, but the counts and service times are inaccurate. User Response: Notify the Strobe system programmer. STR4231E CICS SERVICE TIME CAPTURE LOST DATA FOR nn.nn SECONDS. TRANSACTIONS NOT RECORDED = tran Explanation: Strobe did not record tran CICS transactions because the buffer size was not large enough. Strobe for CICS could not collect data for nn.nn seconds. System Action: Strobe continues processing, but the reported transaction counts and service times could be inaccurate. User Response: Specify a larger buffer with the CICS=CAPTBUFF parameter on the OTHERS panel, or increase the sampling rate to allow Strobe to empty the buffer more frequently. STR4232E ABEND THRESHOLD EXCEEDED - modname DISABLED Explanation: Strobe for CICS encountered a severe error in module modname. System Action: Strobe continues sampling, but CICS-specific reports could be incomplete. User Response: Notify the Strobe system programmer. STR4233E CICS SERVICE TIME CAPTURE DISABLED DUE TO LOST DATA Explanation: The Service Time buffer exceeded the limit of buffer full conditions. System Action: Strobe continues sampling, but cannot collect performance information for the CICS Transaction Profile. The CICS Transaction Profiling reports could be incomplete. User Response: Specify a larger buffer through the CICS=CAPTBUFF parameter or increase the sampling rate to allow Strobe to empty the buffer more frequently. STR4234E number CICS TRANSACTION PROFILING DISABLED DURING MEASUREMENT AT SAMPLE Explanation: Strobe for CICS was disabled during the measurement of sample number. System Action: Strobe continues processing without collecting performance information for the CICS Transaction Profile. Other Strobe reports are complete. User Response: View the Strobe log error messages and follow the recommended response. STR4235W TRANSACTION PROFILE NOT AVAILABLE-DEFAULT TO CICS PERFORMANCE SUPPLEMENT Explanation: Strobe for CICS could not locate module STRBTXP and, therefore, could not complete the Transaction Profile request. System Action: statistics. Strobe continues sampling, but only collects CICS Performance Supplement User Response: Support. Verify the installation of Strobe for CICS and contact Compuware Customer 3-88 Strobe Messages Guide STR4236E CICS DFHxxxx IPROC error Explanation: Strobe transaction profiling was attempting to implant the intercept at DFHxxxx but could not identify the associated IPROC. System Action: Depending on the DFH module listed, transaction profiling may be disabled. User Response: Contact Compuware Technical Support. STR4237E CICS DFHDSAT CHANGE_MODE xxxxx mis-match Explanation: Strobe transaction profiling was attempting to implant the intercept at DFHDSAT, but the expected code at ENTRY or EXIT was not found. System Action: Transaction profiling will continue without TCB switching information. This most likely occurs after CICS maintenance is applied. User Response: STR4310E Contact Compuware Technical Support. GETMAIN FAILURE - IMS DATA COLLECTOR DISABLED Explanation: A GETMAIN failure occurred when the IMS data collector was trying to obtain virtual storage for its work area. System Action: Strobe continues sampling without the IMS data collector. User Response: Notify the Strobe system programmer. STR4320E IMS RELEASE OR REGION TYPE NOT SUPPORTED - DATA COLLECTOR DISABLED Explanation: Strobe does not support the type of IMS region in which the target job is running. Strobe supports Message Processing Regions (MPRs), IMS Fast Path regions (IFPs), Batch Message Processing regions (BMPs), Data Language/One batch applications (DL/I), control regions (CTL), and DL/I Separate Address Spaces (DLISAS). System Action: Strobe continues sampling without the IMS data collector. User Response: Notify the Strobe system programmer. STR4410E GETMAIN FAILURE - DB2 DATA COLLECTOR DISABLED Explanation: A GETMAIN failure occurred when the DB2 data collector was trying to obtain virtual storage for its work area. System Action: Strobe continues sampling without the DB2 data collector. User Response: Notify the Strobe system programmer. STR4411E smid CAPTURE NOT ACTIVATED. COUNTS OR TIMES WILL NOT BE AVAILABLE. RC=xx REASON=yy. Explanation: Strobe was unable to establish an intercept for this measurement. System Action: Processing continues. SQL reporting will not contain counts or times. User Response: Contact Compuware Customer Support. STR4501E GETMAIN FAILURE IDMS DATA COLLECTOR program name DISABLED Explanation: work area. The Strobe CA-IDMS data collector was unable to obtain virtual storage for its System Action: Strobe continues sampling without the CA-IDMS data collector. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system STR4502E IDMS CV NUCLEUS REFRESHED - DATA COLLECTION DISABLED Explanation: The CA-IDMS nucleus was refreshed while the measurement task was sampling. System Action: Strobe continues sampling without the CA-IDMS data collector. The CAIDMS and ADS/O Attribution reports in the Performance Profile will be incomplete. User Response: completed. Rerun the measurement session after the CA-IDMS nucleus refresh is Messages Produced by Strobe STR4503E 3-89 IDMS DATA COLLECTION MODULE - STRBmodname - NOT IN STROBE LIBRARY Explanation: The CA-IDMS data collector or DML batch attributor attempted to load the release-specific data collection module STRBmodname, but did not find the module. System Action: Strobe continues sampling without CA-IDMS data collection or DML batch attribution data. User Response: STR4601E Notify the Strobe system programmer. GETMAIN FAILURE - CICS/DBCTL SUPPLEMENT DISABLED Explanation: A GETMAIN failure occurred when the CICS/DBCTL data collector attempted to obtain virtual storage for a work area. System Action: Strobe continues sampling without CICS/DBCTL attribution data. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system STR4602E CICS/DBCTL RELEASE NOT SUPPORTED Explanation: Strobe attempted to measure a CICS/DBCTL region running an unsupported release of either IMS or CICS. System Action: Strobe continues sampling without CICS/DBCTL attribution data. User Response: Notify the Strobe system programmer. STR4701E ADABAS RELEASE NOT SUPPORTED Explanation: Strobe attempted to measure an Adabas region that was running a release of Adabas that Strobe does not support. System Action: Strobe continues sampling but does not collect Adabas data. User Response: Notify the Strobe system programmer. STR4800E MQSERIES DATA COLLECTION DISABLED - reason Explanation: Strobe disabled Strobe for WebSphere MQ processing because of reason. The following are possible causes: • • • • • • • • • • Invalid input to routine STRBDCSQ Invalid input to subroutine subroutine Abend threshold exceeded Unable to access the required MVS data Invalid input to STRBCSQC Invalid input to STRBCSQT Abend threshold exceeded STRBSCQC Abend threshold exceeded STRBCSQT Invalid ALET returned by #PC service Internal diagnostic data for reason is given in code. System Action: Strobe continues sampling without collecting MQSeries data. User Response: Contact Compuware Customer Support. STR4801I MQSeries data collection disabled: reason Explanation: The Measurement Facility disabled Strobe for WebSphere MQ processing because of reason. The possible reasons are: • • • • • • • • threshold for undefinable queue managers exceeded release xyz of MQSeries is not supported measurement is of a queue manager address space could not obtain working storage no queue managers defined to MVS task in sample is not connected to a queue manager program check in intercept module abend detected in intercept module. System Action: Strobe continues sampling without collecting more MQSeries data. User Response: Notify the Strobe system programmer. If the task was not connected to a queue manager, initiate a connection to the appropriate queue manager for the task. 3-90 Strobe Messages Guide STR4802E MQSERIES ATTRIBUTION DISABLED-reason Explanation: Strobe disabled Strobe for WebSphere MQ processing because of reason. The following are possible causes: • Invalid input to routine STRBACSQ or • The abend threshold was exceeded System Action: modules. Strobe continues sampling, but does not attribute some activity in MQSeries User Response: Notify the Strobe system programmer. STR4803I MQSERIES ATTRIBUTION DISABLED -- COULD NOT OBTAIN WORKING STORAGE Explanation: The Measurement Facility disabled the MQSeries attributor because Strobe for WebSphere MQ could not obtain storage for an internal work area. System Action: None. User Response: Notify the Strobe system programmer. STR4804I ATTRIBUTION OF USER’S COMMON MQSERIES USER MODULE IS DISABLED-reason Explanation: Strobe for WebSphere MQ does not identify the caller of the user’s common MQSeries user module because of reason. The following are possible causes: • The common user module is the module being measured • The threshold for the number of failed attempts to identify the invoker has been reached System Action: Strobe continues processing. Strobe for WebSphere MQ collects other data, but does not identify the invokers of the MQSeries common user module. User Response: Notify the Strobe system programmer. To identify the invoker of the common user module issuing the MQSeries APIs, separate the common user module from the one being measured. If the number of failed identifications of the common user module exceeds the threshold during the measurement, ensure that you are using the standard MVS linkage conventions for the common user module and the module that invoked it. If you are measuring a CICS region, ensure that you are using CICS calling conventions. STR4805I MQSERIES MQI COUNTS DISABLED – [text] Explanation: MQICAPTURE has been disabled because of an error in processing explained in text: • • • • • • Intercept module not linked Intercept module invalid CICS environment not active CICS stub not found Implant failure Storage obtain failure System Action: Further capture is terminated but existing data will be reported. User Response: Notify the Strobe system programmer. STR4805I MQSERIES TRANSACTION PROFILING DATA SPACE FULL AT SAMPLE NUMBER-number Explanation: The Strobe MQSeries Transaction Profiling Dataspace encountered a full condition for the sample number number. System Action: Strobe continues processing, but does not create queue tokens to be used by the CICS Transaction Profile Function. User Response: STR4806I Increase the data space size by increasing the CICS=DISSIZE parameter. MQSERIES FOR TRANSACTION PROFILING DISABLED BY strbcsqt Explanation: The MQSeries component, strbcsqt, encountered a severe error. System Action: Strobe continues processing, however, the MQSeries data will not appear in CICS Transaction Profile reports. User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR4807E 3-91 LOAD OF CICS TASK TABLE modname FAILED - CICS DATA COLLECTOR DISABLED Explanation: Strobe for CICS was unable to load the table of CICS system transactions. The CICS data collector is disabled. System Action: Strobe continues processing, but does not collect CICS data. User Response: library. Verify that the CICS System Task Table STRBTSK is in the appropriate load STR4808I MQ implant successful at sample #nnnnnnnn Explanation: Strobe detected MQ activity at sample #nnnnnnnn and successfully implanted its MQ intercept. The sample # at which the MQ implant was made is typically low for online systems such as CICS or IMS because MQ will already be active in these regions. The implant sample # for batch MQ is typically higher depending on the amount of work performed by your batch procedure before MQ activity is initiated and MQ modules are loaded into virtual storage. Strobe won’t implant its intercept until MQ activity is detected. System Action: Strobe continues processing and MQ data collection is initiated. User Response: The MQ API calls are typically very fast, so it is possible for an MQ call to be initiated and completed between Strobe samples. If that is the case, Strobe will not see this activity and you will not see this message. Try increasing your sampling rate so that Strobe has a chance to sample the MQ activity. If your reports appear to be missing a significant amount of MQ data and the sample # at which data collection started was high, this may be an indication of something wrong in your environment. Check your Strobe report for other performance related issues. Otherwise, no response is required. STR4901E JVM DATA COLL STRBJDC1 DISABLED BECAUSE [text] Explanation: The data collector STRBJDC1 encountered a situation preventing it from continuing to process samples. It disables itself, and measurement continues without further JVM measurement. One of the following messages appears in text: • MODULE COULD NOT OBTAIN WORKING STORAGE - STRBJDC1 attempted to obtain working storage for itself or for the JVM Global Workarea, but the Storage Obtain function failed. • TOO MANY TOKEN COMPRESSION ERRORS - STRBJDC1 encountered an excessive number of errors when tokenizing Java names. System Action: STRBJDC1 stops processing the sample and disables itself. Measurement may continue, but no further JVM sample processing takes place. User Response: For a message concerning storage, contact your Strobe system programmer. For a message concerning the JVM release, ensure that the version of JVM you are trying to measure is supported by the version of Strobe in use. For a message concerning token compression errors, contact Compuware Customer Support. STR4902W SAMPLE IGNORED BY STRBJDC1 BECAUSE [text] Explanation: The data collector STRBJDC1 cannot successfully process the current sample. It issues a warning message and exits. One of the following messages appears in text: • DCICALL2 WAS OUTSIDE RANGE - STRBJDC1 was called with an argument value outside the permissible range of values. The JVM processing portion ends for that sample, but measurement continues. • DCICALL2 WAS ZERO - STRBJDC1 was called with an argument value of zero. The JVM processing portion of that sample by STRBJDC1 ends, but measurement continues. • LONGNAME TOKEN COMPRESSION ERROR - The longname token subroutine called by STRBJDC1 exited with a return code greater than 4. STRBJDC1 stops processing that particular sample, but measurement continues. • LONGNAME EXCEEDED BUFFER SIZE - The longname handled by STRBJDC1 exceeded the permissible length. STRBJDC1 stops processing the sample, but measurement continues. 3-92 Strobe Messages Guide System Action: STRBJDC1 ceases processing the current sample, but sample processing continues. STRBJDC1 continues processing with the next sample. User Response: For a message concerning buffer size, ensure that the names which are in use are within the length of name supported by the version of Strobe in use. For all other messages, contact Compuware Customer Support. STR4911E JVM DATA COLL STRBJDC2 DISABLED BECAUSE [text] Explanation: The data collector STRBJDC2 encountered a situation preventing it from continuing. It disables itself and measurement continues without further JVM measurement. One of the following messages appears in text: • LOCAL WORKAREA MISSING AFTER INIT - STRBJDC2 found that its workarea was no longer available. • LOCAL WORKAREA FAILED EYECATCHER - STRBJDC2 found that the working storage eyecatcher was no longer present. • GLOBAL COMM AREA MISSING AFTER INIT - STRBJDC2 found that the GLOBAL COMM AREA was no longer available. • GLOBAL COMM AREA FAILED EYECATCHER - STRBJDC2 found that the GLOBAL COMM AREA eyecatcher was no longer present. • SAMPLE ROUTINE FOUND BAD WORKAREA - STRBJDC2 found that a workarea eyecatcher was no longer present. • IDENTIFY ROUTINE FOUND BAD WORKAREA - STRBJDC2 found that a workarea eyecatcher was no longer present. • MODULE DID NOT OBTAIN WORKING STORAGE - STRBJDC2 attempted to obtain working storage for itself, but the Storage Obtain function returned an error code. • MODULE COULD NOT OBTAIN GLOBAL STORAGE - STRBJDC2 attempted to obtain working storage for the JVM Global Workarea, but the Storage Obtain function returned an error code. System Action: STRBJDC2 stops processing the sample and disables itself. Measurement may continue, but no further JVM sample processing takes place. User Response: STR4912W Contact Compuware Customer Support. SAMPLE IGNORED BY STRBJDC2 BECAUSE [text] Explanation: The data collector STRBJDC2 cannot successfully process the current sample. It issues a warning message and exits. One of the following messages appears in text: • DCICALL2 WAS OUTSIDE RANGE - STRBJDC2 was called with an argument value outside the permissible range of values. The JVM processing portion ends for that sample, but measurement continues. • DCICALL2 WAS ZERO - STRBJDC2 was called with an argument value of zero. The JVM processing portion of that sample by STRBJDC2 ends, but measurement continues. • SAMPLE CALL NOT A DIRECTED CALL - STRBJDC2 was called during sample time, but the call was not a directed call. STRBJDC2 stops processing that particular sample, but measurement continues. • CALLER NOT IN CALLER TABLE - STRBJDC2 was not activated by a legal caller. STRBJDC2 stops processing the sample, but measurement continues. System Action: STRBJDC2 ceases processing the current sample, but sample processing continues. STRBJDC2 continues processing with the next sample. User Response: STR4921E Contact Compuware Customer Support. JVM ATTRIBUTOR STRBJVMA DISABLED BECAUSE [text] Explanation: A failure occurred in the Strobe for Java Attributor. The explanation appears in text: • AN ABEND HAS OCCURRED - The Strobe for Java Attributor is disabled because an ABEND occurred. • JVM RELEASE NOT SUPPORTED - The release level of the Java Virtual Machine is not supported by Strobe. • MODULE COULD NOT OBTAIN WORKING STORAGE - The Strobe for Java Attributor was unable to obtain storage for its work area. • MODULE COULD NOT OBTAIN GLOBAL WORK AREA - The Strobe for Java Attributor was unable to obtain storage for use by the modules that comprise Strobe for Java. Messages Produced by Strobe System Action: incomplete. Strobe continues sampling, but the Strobe Performance Profile will be User Response: Notify the Strobe system programmer. 3-93 STR4922W JVM ATTRIBUTOR STRBJVMA ERROR PROCESSING TARGET DATA. ATTRIBUTION CONTINUES, BUT WILL LOCATE THE MAIN METHOD. Explanation: System Action: A failure occurred in the Strobe for Attributor when processing Java targeting information. System Action: Strobe continues sampling, but the JAVA CPU USAGE BY CALLED METHOD and JAVA WAIT TIME BY CALLED METHOD reports in the Strobe Performance Profile will not reflect the requested targets. User Response: Notify the Strobe system programmer. STR4923W JAVA METHOD IGNORED BY JVM ATTRIBUTOR STRBJVMA BECAUSE LONGNAME EXCEEDED BUFFER SIZE. Explanation: Strobe for Java detected one or more qualified method names (package plus signature) that exceeded the internal buffer size of 1024 bytes reserved for such names. System Action: Strobe stops processing the sample in which it detected the longname. User Response: Reduce the size of qualified method names to less than 1024 bytes and resubmit the request. STR4924E JMETHODID DATASPACE ALLOCATION FAILED - RC xxxxxxxx Explanation: Strobe for Java attempted to allocate its dataspace and was unable to do so. xxxxxxxx represents an eight byte decimal return code from the Strobe Dataspace Management routine. System Action: The Strobe for Java routine disables itself from further processing. Measurement session continues. User Response: Strobe log. STR4925W Contact Compuware Customer Support and provide sample dataset and JV5D JMETHODID xxxxxxxxxxxxxxxx NOT FOUND AT SAMPLE # yyyyyyyy Explanation: Strobe for Java could not find the sixteen byte method ID passed by the Strobe Java Agent in its dataspace. yyyyyyyy represents an eight byte decimal sample number in which this event occurred. System Action: Measurement session continues. User Response: Strobe log. Contact Compuware Customer Support and provide sample dataset and STR4926I JV5D RECEIVED JMETHODID xxxxxxxxxxxxxxxx AT SAMPLE # yyyyyyyy Explanation: xxxxxxxxxxxxxxxx represents a sixteen byte method ID received from the Strobe Java Agent. yyyyyyyy represents an eight byte decimal sample number in which this event occurred. System Action: Measurement session continues. User Response: None. STR4927I JV5D ZERO METHODS RETURNED AT SAMPLE # xxxxxxxx Explanation: xxxxxxxx represents an eight byte decimal sample number in which the zero method event occurred. System Action: Measurement session continues. User Response: None. STR4928W zzzzzzzz JV5D JMETHODID xxxxxxxxxxxxxxxx DSPACE PUT ERROR - RC yyyyyyyy, SAMPLE # Explanation: Strobe for Java was unable to write a sixteen byte method ID to its dataspace. yyyyyyy represents an eight byte decimal return code from the Strobe Dataspace Management routine. zzzzzzzz represents an eight byte sample number in which this event occurred. 3-94 Strobe Messages Guide System Action: Measurement session continues. User Response: Strobe log. Contact Compuware Customer Support and provide sample dataset and STR4929E JV5D POSTED BY TIMER EXIT AT SAMPLE # xxxxxxxx Explanation: Strobe for Java was awakened by its timer exit routine, which indicates a possible problem with the Strobe Java Agent. xxxxxxxx represents an eight byte decimal sample number in which this event occurred. System Action: The Strobe for Java routine disables itself from further processing. Measurement session continues. User Response: Strobe log. Contact Compuware Customer Support and provide sample dataset and STR4930W STROBE FOR JAVA ENCOUNTERED JAVA METHOD NAMES GREATER THAN 1024 BYTES nnnnnn TIMES DURING SAMPLING Explanation: nnnnnn is the number of times that Strobe for Java encountered a method name greater than 1k during sampling. System Action: Strobe for Java will not include those samples in any of its reports. User Response: None required. STR4931E JV5D ENCOUNTERED THE FOLLOWING ERROR: xxxxxxxxxxxxxxxxxxxx Explanation: Strobe for Java encountered one of the following three possible situations during its IDENTIFY phase: • 1 - No CAA address - Strobe was unable to obtain the address of the Language Environment CAA. • 2 - Bad LE control blk - Strobe was unable to validate key Language Environment control blocks. • 3 - Bad env variable - An error occurred while processing environment variables. System Action: Strobe for Java was unable to construct necessary records for Java Environment Report. Measurement session continues. User Response: Contact Compuware Customer Support and provide sample dataset and Strobe log dataset. STR5001W WAS OPTION LICENSED BUT WAS=N0 SPECIFIED IN PARMLIB - WAS DATA COLLECTION DISABLED Explanation: You are measuring a WebSphere region, and your site is licensed for Strobe for WebSphere Application Server, but WebSphere data collection was not activated for your measurement request. System Action: Strobe for WebSphere Application Server data will not be present in your Performance Profile reports. User Response: None required. If you want to see WebSphere activity, either contact your Strobe system programmer to set the global option on, or specify WAS=Y on the Strobe data collectors panel. STR5002E EXCEEDED WEBSPHERE DATA COLLECTOR DISABLED - MAX CONCURRENT WAS MEASUREMENTS Explanation: The limit for concurrent executions of Strobe for WebSphere Application Server measurements has already been met. (The limit is set in the WASCNTS parameter). System Action: Measurement continues, but Strobe for WebSphere Application Serve reporting will not be present in your measurement reports. User Response: Submit your measurement later, or contact the Strobe system programmer to increase the value in the WASCNTS parameter. STR5003E nnnnnn DATASPACE ERROR - xxxxx COMMAND - RETURN CODE rc Explanation: This error reflects one of the following situations: • nnnnnn is the dataspace name, which can be WAS LOCAL or WAS SCOPE=ALL. • xxxxx can be GET, CREATE, or DELETE. Messages Produced by Strobe 3-95 • rc is a 2-digit error code. System Action: If the command was DELETE, your reports will not be affected, but you should report the error message to your system programmer. If the command was CREATE, your Performance Profile will not include any Strobe for WebSphere Application Server reports. If the command was GET, your Strobe for WebSphere Application Server reports will be incomplete. Explanation: STR5004E Contact the Strobe system programmer. WAS DATA COLLECTOR INTERNAL ERROR xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Explanation: This is an internal error. One of several possible self-explanatory and detailed error statements will appear in the message. System Action: Strobe for WebSphere Application Server is not able to continue for this measurement. The Strobe for WebSphere Application Server reports will be incomplete, but the measurement will continue for other components in the measured address space. User Response: Notify Strobe support. STR5006E WAS DATA COLLECTOR DISABLED BECAUSE DATASPACE PC ROUTINE IS UNAVAILABLE Explanation: Internal error. System Action: Strobe for WebSphere Application Server is unable to execute in this measurement, but the measurement will continue for other components. User Response: STR5008E Notify Compuware Customer Support. WAS DATA COLLECTION DISABLED -- STRBBB0S UNABLE TO OBTAIN WORKAREA Explanation: The Strobe for WebSphere Application Server data collector was unable to obtain memory in the measured address space. System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but measurement will continue for other components. User Response: Increase the region size for the measured address space and re-run. STR5009E WAS DATA COLLECTION DISABLED -- ABEND IN LOGIC THAT INITS SCOPE=ALL DATASPACE Explanation: Internal error. System Action: Strobe for WebSphere Application Server is unable to execute in this measurement, but measurement will continue for other components. User Response: Notify Compuware Customer Support. STR5010E WAS DATA COLLECTION DISABLED -- UNABLE TO ENQUEUE ON QNAME qname RNAME rname Explanation: The Strobe for WebSphere Application Server data collector is unable to get control of the enqueued-upon resource where: • qname - the characters STRB followed by the Strobe release number • rname - the Strobe version character followed by the characters WASDS1 System Action: Strobe for WebSphere Application Server will not include those samples in any of its reports. User Response: STR5011E Try again later. WAS DATA COLLECTION DISABLED -- ENQ ON qname XXXX rname Explanation: Explanation: Explanation: XXXX FAILED RC XX Explanation: The Strobe for WebSphere Application Server data collector is unable to get control of the enqueued-upon resource where: • qname - the characters STRB followed by the Strobe release number 3-96 Strobe Messages Guide • rname - the Strobe version character followed by the characters WASDS1 System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but the measurement will continue for other components. User Response: STR5012E Try again later. WAS DATA COLLECTION DISABLED -- DEQ ON qname XXXX rname XXXX FAILED RC XX Explanation: The Strobe for WebSphere Application Server data collector is not able to get control of the enqueued-upon resource where: • qname - the characters STRB followed by the Strobe release number • rname - the Strobe version character followed by the characters WASDS1 System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but measurement will continue for other components. User Response: STR5013E None required. WAS DATA COLLECTION DISABLED -- STRBWENV UNABLE TO OBTAIN WORKAREA Explanation: space. The data collector was not able to obtain memory in the measured address System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but the measurement will continue for other components. User Response: STR5014E Increase the region size for the measured address space and re-run. WAS DATA COLLECTION DISABLED -- STRBWDRN UNABLE TO OBTAIN WORKAREA Explanation: space. The data collector was not able to obtain memory in the measured address System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but the measurement will continue for other components. User Response: STR5015E Increase the region size for the measured address space and re-run. WAS DATA COLLECTION DISABLED -- STRBWWRT UNABLE TO OBTAIN WORKAREA Explanation: space. The data collector was not able to obtain memory in the measured address System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but the measurement will continue for other components. User Response: STR5016E Increase the region size for the measured address space and re-run. WAS DATA COLLECTION DISABLED -- THE WAS OPTION IN MSAS IS NOT ACTIVE Explanation: During initialization for this measurement, it was determined that the WAS option in the MSAS was not currently operational. This could be caused as the result of a prior abend in the Strobe for WebSphere Application Server SMF exit or as the result of a MODIFY command to STOPWAS. System Action: Strobe for WebSphere Application Server is not able to execute in this measurement, but the measurement will continue for other components. User Response: programmer. STR5050E Try again later. If the problem persists, notify your site’s Strobe system WEBSPHERE APPLICATION SERVER RELEASE { XXXX | UNSUPPORTED | UNKNOWN } Explanation: The WebSphere release is not supported or cannot be determined: • nnnn UNSUPPORTED -- Strobe does not support version nnnn of WebSphere • 0000 UNKNOWN -- Strobe could not determine the version of WebSphere. System Action: Strobe for WebSphere Application Serve is unable to execute in this measurement, but measurement will continue for other components. Note that if your LPAR is running very slowly, it can take longer for the release to be formatted within a WebSphere server address space than it can take for the data collector to be active and querying for the release information. Messages Produced by Strobe 3-97 User Response: If the release is unsupported, notify your Strobe system programmer. If the release is unknown, try your measurement again later. STR5051W WEBSPHERE APPLICATION SERVER RELEASE nnnnnnnnnnn IS UNSUPPORTED. PROCESSING WILL CONTINUE. Explanation: System Action: data. The WebSphere release is not supported. Strobe for WebSphere Application Server continues to collect measurement User Response: Contact your Strobe system programmer to determine which versions of WebSphere Strobe supports. Messages Returned in Response to Sampling Control Commands The Strobe measurement task returns the following messages in response to sampling control commands sent to the Strobe measurement task via the Strobe SEND operation. STR5300I STROBE SESSION ENDED AT time ON date FOR JOB jobname, REQUEST nnnn Explanation: A Strobe measurement session ended at time time on date date, jobname jobname, and request number nnnn. Strobe issues this message when the NOTIFY parameter was specified on the ADD operation. System Action: Strobe has completed sampling. User Response: None required. STR5301I STROBE RUNNING [- SsssDddd HAS ttttt/eeeee SAMPLES] Explanation: Strobe received a START or STATUS command. The sample dataset whose loworder name syllable is SsssDddd contains ttttt total samples and eeeee execution samples. If the sample count message does not appear, Strobe opened a new sample dataset but did not collected any samples. System Action: dataset. Strobe starts or continues sampling, placing the samples into the sample User Response: None required. STR5302I STROBE RUNNING AND SWITCHED - SsssDddd HAS ttttt/eeeee SAMPLES Explanation: Strobe received a SWITCH command. The sample dataset whose low-order name syllable is SsssDddd contains ttttt total samples and eeeee execution samples and is closed and ready for reporting. System Action: Strobe continues sampling, now using a sample dataset whose low-order syllable is SsssDddd+1. User Response: STR5303I OPEN} None required. STROBE SUSPENDED {- SsssDddd HAS ttttt/eeeee SAMPLES|- NO SAMPLE DATA SET Explanation: Strobe received a STATUS command. If a sample dataset is open, its low-order syllable name is SsssDddd, it contains ttttt total samples and eeeee execution samples. It is not available for reporting. Otherwise, no sample dataset is open. System Action: Strobe is not sampling. User Response: None required. STR5304I STROBE SUSPENDED - NO SAMPLE DATA SET OPEN Explanation: Strobe received a STOP command while in the suspended state with an open sample dataset. The sample dataset is closed and is available for reporting. System Action: Strobe takes no action and sampling remains suspended. No sample dataset is open. 3-98 Strobe Messages Guide User Response: STR5305I None required. STROBE TERMINATING Explanation: Strobe received a QUIT command. If Strobe is sampling, the current sample dataset is closed and is available for reporting. System Action: Strobe stops sampling and cannot be restarted with a SEND operation. User Response: To initiate further sampling, submit a new Strobe request statement, using the ADD operation. STR5310I STROBE MEASUREMENT SESSION SUSPENDING Explanation: Strobe received a SUSPEND or STOP command. System Action: Strobe stops sampling. User Response: None required. STR5315W STROBE NOT SAMPLING - REQUEST IGNORED Explanation: Strobe received a SWITCH, STOP, or SUSPEND command. Strobe is not sampling and has no open dataset. System Action: Strobe does not process the command. User Response: To resume sampling, enter a START command. STR5318W STROBE SAMPLING - REQUEST IGNORED Explanation: Strobe received a START command, but sampling is already in process. System Action: Strobe does not process the command. User Response: None required. STR5320I STROBE MEASUREMENT SESSION RESUMED Explanation: Strobe received and processed a START command. System Action: Strobe begins sampling. User Response: None required. Messages Returned by the Session Management Facility The session management facility returns the following messages in response to Strobe commands, writing them to the SYSPRINT dataset and to an operator’s terminal when the request originated there. Strobe/ISPF users receive messages at the terminal and can also access them from the log dataset where the session management facility records them. Messages other than those produced in response to status commands are also written to the Strobe log. STR6001I STROBE SESSION MANAGER release CALLED FROM {job | started_task} jobname AT time, SYSTEM=sysname Explanation: You initiated execution of the session manager for Strobe release release, from either a batch job or a started task, under a job named jobname, at time time. The MVS system name of the host is sysname. System Action: Strobe continues processing. User Response: None required. STR6005I STROBE SESSION MANAGER release COMPLETED FOR {job|started task} jobname RC=rc SYSTEM=sysname Explanation: You initiated execution of the session manager for Strobe release release, on system sysname from a batch job or a started task under a job named jobname. Messages Produced by Strobe 3-99 A zero return code (RC=00) indicates that all operations requested were processed successfully. A nonzero return code indicates that Strobe detected an error when processing at least one operation. The error was reported in an earlier message. Refer to “Return Codes and Severity Codes” on page 1-2 for an explanation of the return codes and their associated severity codes. The MVS system name of the host computer is sysname. System Action: Strobe completed execution for the job. User Response: If the return code is not zero, locate the message reporting the error, and follow the recommended action in the message description. STR6006E commandname OPERATION FOR REQUEST nnnn ENDED WITH ERROR Explanation: The processing of command commandname for request number nnnn ended with an error condition. System Action: Strobe may not have processed the command, as indicated by the error messages that preceded this message. User Response: programmer. STR6007I Check the log for additional messages and notify the Strobe system DESIGNATED INTERNAL STRUCTURE structname INVALID Explanation: Strobe attempted to free an unallocated or a negative amount of storage in structure structname. System Action: Strobe does not attempt to free the storage. User Response: None required. STR6101I STROBE release CALLED FROM {batch job | TSO session | started_task} jobname AT time date SYSTEM=sysname Explanation: Execution of Strobe at version release was initiated from either a batch job, a TSO session, or a started task, under a job named jobname, at time time, on date date. The MVS system name of the host is sysname. System Action: Strobe is ready to process Strobe control statements. User Response: None required. STR6102S INVALID OPERATING SYSTEM OR OPERATING SYSTEM LEVEL Explanation: Strobe does not support the operating system or operating system release level. System Action: Strobe terminates. User Response: Ensure that the specific Strobe option supports your operating system configuration. Notify the Strobe system programmer. STR6103S INSTALLATION ERROR - STROBE NOT MARKED REENTRANT Explanation: Either the load module for the session manager, STRBCSM, is not marked as reentrant, or the load module for the session requester, STRBCSR, is not marked as reentrant. System Action: Strobe terminates. User Response: Notify the Strobe system programmer. There has probably been an installation error. The Strobe system programmer should check the linkage editor output listing from the Strobe installation job to verify that the load module has been marked as reentrant. If not, reinstall the Strobe modules with link edit options RENT, REUS, and REFR. STR6104E REQUEST REJECTED - SESSION MANAGER IS NOT ACTIVE ON SYSTEM sysname Explanation: This message is issued in response to a Strobe request issued on system sysname. A component of Strobe, the session manager, is either not active or has failed on system sysname. To use Strobe, the session manager must be active. System Action: Strobe does not process the request. User Response: programmer. To use Strobe, you must start the session manager. Notify the Strobe system 3-100 Strobe Messages Guide STR6105I STROBE release COMPLETED FOR {JOB|TSO USER|STRT TSK} jobname RC=rc SYSTEM=sysname Explanation: Execution of Strobe release release was initiated from a batch job, a TSO session, or a started task under a job named jobname. A zero return code (RC=00) indicates that all operations requested have been processed successfully. A nonzero return code indicates that Strobe detected an error when processing at least one operation. The error was reported in an earlier message. Refer to “Return Codes and Severity Codes” on page 1-2 for an explanation of the return code and the associated severity code. The MVS system name of the host computer is sysname. System Action: Strobe completed processing the job. User Response: If the return code is not zero, locate the message reporting the error, and follow the action recommended in the message description. STR6106E MAXIMUM NUMBER OF REQUESTS EXCEEDED - REQUEST IGNORED Explanation: The number of requests submitted to Strobe exceeds the number specified by your Strobe system programmer during the installation of the Strobe system. System Action: Strobe accepts no further requests. User Response: Notify the Strobe system programmer who can delete the completed requests with a DELETE or CLEAN command. STR6107W NUMBER OF REQUESTS IS APPROACHING LIMIT - DELETE COMPLETED REQUESTS Explanation: The number of requests accepted by Strobe exceeds 75% of the number specified by your Strobe system programmer during the installation of the Strobe system. System Action: Strobe accepts and processes the current request. User Response: Notify the Strobe system programmer who can delete the completed requests or outdated AutoStrobe requests with a DELETE or CLEAN command. STR6108I PARMS=xxxxxxxx Explanation: This message xxxxxxxx echoes the PARMS field received in a START command or EXEC statement used to invoke Strobe. System Action: Strobe continues processing. User Response: None required. STR6109S STROBE NOT CALLED FROM AUTHORIZED LIBRARY Explanation: caused by: The module STRBCSM was called from an unauthorized library. This can be • An unauthorized library in the STEPLIB concatenation • Executing Strobe in an unauthorized dataset System Action: The session manager cannot create the Strobe environment. User Response: If Strobe is accessed via STEPLIB, either remove any unauthorized partitioned datasets from the STEPLIB concatenation or move the Strobe library to an authorized library or link list dataset. Contact the Strobe system programmer to determine if Strobe is in a link list. STR6110S STROBE NOT CALLED AS AUTHORIZED PROGRAM Explanation: caused by: The module STRBCSM was not invoked as an authorized program. This can be • An unauthorized library in the STEPLIB concatenation • Installing Strobe as an unauthorized program System Action: The session manager cannot create the Strobe environment. User Response: If Strobe is accessed via STEPLIB, either remove any unauthorized partitioned datasets from the STEPLIB concatenation or move the Strobe library to an authorized library or link list dataset. Contact the Strobe system programmer to determine if Strobe is in the link list and was installed properly. Messages Produced by Strobe STR6111S 3-101 STROBE SESSION MANAGER ALREADY ACTIVE Explanation: The session manager is already active. System Action: The duplicate version of Strobe will terminate and processing of the original version will continue unaffected. User Response: STR6112E None required. CANNOT PERFORM ENVIRONMENT CHANGE - STROBE IN USE BY OTHER JOBS Explanation: You cannot change the Strobe environment until other active executions of Strobe have terminated. System Action: Strobe continues processing. User Response: To determine who are the active Strobe users, invoke the STATUS command. Wait until all other executions of Strobe terminate and resubmit the environment request. STR6113E REQUEST REJECTED [ON SYSTEM sysname -] INSUFFICIENT ACCESS AUTHORITY Explanation: You submitted a request to either measure a job or to access an existing request. If identified, the system is sysname. The Strobe security interface (access filter) determined that you do not have access to the job specified in the request. System Action: The request is rejected and processing continues. User Response: To enable you to measure this job, the Strobe system programmer or security administrator must grant you access to the job. STR6114I ACCESS FILTER DISABLED ON SYSTEM sysname BY INSTALLATION REQUEST Explanation: During startup of the session manager on system sysname, Strobe determined that the access filter is disabled. The Strobe parameter disabled the access filter. System Action: Strobe continues processing but the security interface is disabled. User Response: None required. STR6115I NO SECURITY SYSTEM FOUND ON SYSTEM sysname - ACCESS FILTER DISABLED Explanation: During startup of the session manager on system sysname, Strobe was unable to locate one of the following security packages: RACF, CA-Top Secret, or CA-ACF2. System Action: Strobe continues processing with the security interface disabled. Strobe will function without security protection. User Response: To obtain access to the security system at your installation, review your installation security procedures with the Strobe system programmer. STR6116I ACCESS FILTER WILL BE ENABLED FOR security ON SYSTEM sysname Explanation: During startup of the session manager on system sysname, Strobe determined that security package security is present. security can be RACF, TSS (CA-Top Secret), or ACF2 (CAACF2). System Action: Strobe enabled the security interface for that security package. User Response: None required. STR6117I NO REQUESTS FOUND Explanation: You submitted a LIST or CLEAN request, but no measurement requests meet the specified selection criteria. System Action: Strobe does not process the LIST or CLEAN request. User Response: request. If you specified an incorrect request identification, correct and resubmit the STR6118I nnnn {JOBS|PROCESSES} FOUND TO SATISFY REQUEST ON SYSTEM sysname Explanation: Strobe found nnnn jobs on system sysname to satisfy a request to display active jobs. Strobe found nnnn processes on system sysname to satisfy a request to display active processes. 3-102 Strobe Messages Guide System Action: Strobe continues processing. User Response: None required. STR6119I STOP COMMAND RECEIVED FROM CONSOLE consoleid Explanation: consoleid. The session manager received a STOP command from operator console System Action: processing. The session manager terminates, removing the environment and ending all User Response: None required. STR6120I REQUEST MODIFIED BY INSTALLATION EXIT Explanation: System Action: Strobe determined that installation exit STRBCXAC modified a user request. Strobe continues to process the request. User Response: List the request to determine what options have changed. If the new options create problems, notify the Strobe system programmer. STR6121I REQUEST {nnnn|jobname} NOT FOUND Explanation: Strobe cannot find any request that matches the request number nnnn or jobname jobname given in the LIST operation. Either you specified the wrong request number or jobname, or Strobe deleted the request. System Action: Strobe does not process the LIST request. User Response: request. If you specified an incorrect request identification, correct and resubmit the STR6122W REQUEST {nnnn|jobname} NOT FOUND ON SYSTEM sysname Explanation: Strobe was unable to find on system sysname a request matching the request number nnnn or jobname jobname given in the ADD, CHANGE, DELETE, or SEND operation. Either you specified the wrong request number or jobname, or Strobe deleted the request. System Action: Strobe does not process the request. User Response: request. If you specified an incorrect request identification, correct and resubmit the STR6123W REQUEST ACTIVE - SOME OPERANDS INVALID Explanation: For an active request, you specified a CHANGE operation with an operand other than GOMIN, LIMIT, SAMPLES, OPTIONS, or RETAIN. You cannot change any other keyword operands after the measurement session becomes active. System Action: Strobe processes the request, excluding the unacceptable parameters. User Response: List the request to determine what options have changed. STR6124E REQUEST COMPLETE - CHANGE NOT VALID Explanation: You submitted a CHANGE operation for a measurement request that has already terminated. For a completed request, only a CHANGE operation with RETAIN=COMPLETE=nnn is valid, where nnn is the number of days the request is to be retained. System Action: Strobe does not process the request. User Response: None required. STR6125I STROBE MEASUREMENT SESSION {INITIALIZING|PROCESSING SEND OPERATION| NOT RESPONDING - USE LIST OPERATION LATER|TERMINATING} Explanation: Strobe is processing a request and the Strobe measurement session did not respond to the command. One or more of the following messages can appear in a busy system if the operating system did not give the measurement task enough time to process the request: • INITIALIZING • PROCESSING SEND OPERATION Messages Produced by Strobe 3-103 • NOT RESPONDING (message STR6125W) • USE LIST OPERATION LATER • TERMINATING System Action: If you issued an ADD operation, Strobe displays the STROBE MEASUREMENT SESSION INITIALIZING message as many as four times. On the fifth iteration, Strobe displays the STROBE MEASUREMENT SESSION NOT RESPONDING message, and Strobe terminates. Strobe displays the same series of messages for the SEND operation, except that the messages read STROBE MEASUREMENT SESSION PROCESSING SEND OPERATION. The measurement session continues unless the program being measured terminates, at which point Strobe terminates the measurement task. User Response: STR6126I DENIED Notify the Strobe system programmer if the problem persists. {jobname|username} DID NOT HAVE AN ACEE - ACCESS TO RESOURCES WILL BE Explanation: The Strobe sign-on procedure determined that the job jobname or user username does not have an accessor environment element (ACEE). System Action: If a security system is installed, Strobe will deny the user or job access to all resources or jobs. User Response: Notify the Strobe system programmer. The system programmer may need to disable the access filter. STR6127E DELETE REJECTED - JOB ACTIVE ON SYSTEM sysname Explanation: You specified a DELETE operation for an active measurement session that is running on system sysname. DELETE can be specified only for queued, deferred, or completed requests. System Action: Strobe does not process the request. User Response: Wait until the job completes or use the SEND operation with the QUIT operand to terminate an active measurement session. Then reissue the DELETE operation. STR6128E OPTIONS=NOQUIT NOT POSSIBLE Explanation: You issued an ADD operation specifying OPTIONS=NOQUIT but, during installation, the Strobe system programmer specified JSTCB=NEVER in the Strobe parameter file. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR6129E OPTIONS=NOQUIT IN EFFECT, QUIT INVALID Explanation: You issued a SEND operation with the QUIT option to a request that is running with the NOQUIT option, or you attempted to stop Strobe while a measurement session was active with NOQUIT specified. System Action: Strobe ignores the SEND operation and continues processing. You will not be able to deactivate the Strobe environment unless the Strobe system programmer issues the TERMINATE command. User Response: If the message resulted from a SEND operation, resubmit it, and specify the STOP operand. If you want to stop Strobe, issue the TERMINATE command. STR6130I oper OPERATION COMPLETED Explanation: Strobe successfully performed the indicated operation oper. System Action: Strobe continues processing. User Response: None required. STR6131E JOB NOT ACTIVE ON SYSTEM sysname Explanation: You submitted a request for an active job and that job is not executing on system sysname. System Action: Strobe does not process the request. 3-104 Strobe Messages Guide User Response: Wait until the target jobstep is executing before submitting a request on the Strobe - Add Active Request panel or use the STEP=* command syntax. If you would like to measure a job step that is executing later, submit a request on the Strobe - Add Queued Request panel. STR6132E DUPLICATE JOBS FOUND ON SYSTEM sysname Explanation: Strobe discovered more than one job on system sysname with a jobname that matches the one specified on an ADD ACTIVE request. System Action: Strobe does not process the request. User Response: Determine the ASID number of the target job, and resubmit the request specifying the ASID parameter. STR6133E ADDRESS SPACE FAILED Explanation: Strobe determined that an address space associated with a measurement request no longer exists. System Action: Strobe marks the measurement request completed. User Response: Notify the Strobe system programmer. STR6134W STROBE MEASUREMENT SESSION NOT ACTIVE Explanation: You specified a SEND operation for a job step for which no measurement session is active. System Action: Strobe does not process the request. User Response: Wait until the measurement session becomes active before submitting any SEND requests to it. STR6135W ATTACH FILTER DISABLED - REQUEST CANNOT BE SERVICED Explanation: disabled. You issued a request to measure a future job step, but the attach filter is System Action: Strobe adds the request to the request queue but cannot service the request unless the attach filter is enabled with an ENV operation. User Response: Either enable the attach filter or wait until the job step begins execution and submit another request. STR6136W JOB IS CURRENTLY ACTIVE ON SYSTEM sysname - STEP MAY HAVE BEEN EXECUTED Explanation: Strobe accepted a request to measure a job step. Because the job is already active on system sysname, however, the step may already have executed. System Action: the current job. If the step executed, or is currently executing, Strobe does not measure it in User Response: Notify the Strobe system programmer. The system programmer can use STEP=* to specify that the current job step should be measured. STR6137E STROBE ACTIVE FOR JOB jobname ON SYSTEM sysname - REQUEST REJECTED Explanation: Strobe received an ADD request to measure the current step of an active job jobname for which a measurement session is already active on system sysname. System Action: Strobe assigns a request number to the duplicate ADD request and marks this request as completed. User Response: Use the SEND operation to obtain the current status of the measurement session and to send sampling control commands to Strobe. STR6138W REQUEST nnnn IS A DUPLICATE OF rrrr - REQUEST nnnn IS STILL QUEUED Explanation: An ADD request with the request number nnnn duplicates an existing add request, request number rrrr. System Action: When the target job becomes active, Strobe initiates a measurement session for request rrrr, while request nnnn remains queued. Strobe will initiate a measurement session for request nnnn the next time the target job becomes active. Messages Produced by Strobe 3-105 User Response: If you want Strobe to measure the target job only once, delete request nnnn. Otherwise, none is required. STR6139W ATTACH FILTER WAS DISABLED AT TIME- time Explanation: Strobe determined that the attach filter was disabled at time time. System Action: Strobe accepts both active and queued requests, but measures active requests only. User Response: Notify the Strobe system programmer who can enable the attach filter so that you can measure queued requests STR6140I rrrr jobname status [rrrr jobname status] Explanation: Strobe returns this message in response to a Format 3 LIST command. Strobe lists all outstanding requests rrrr, each with an associated jobname jobname and a status code status. These codes are as follows: (Q) if the request is queued, (A) if the request is active, (C) if the requested measurement session is completed, (D) if the request is deferred, and (S) if the request is suspended or stopped. System Action: Strobe continues processing. User Response: None required. STR6141I nnnn jobname [status sysname] [request-operands] Explanation: Strobe returns this message in response to an ADD, CHANGE, DELETE, LISTGRP command, or a Format 1, 2, or 3 LIST command. Strobe shows request number nnnn, job name jobname, and if present request status status, the system name, sysname and current request parameters [request-operands]. System Action: Strobe continues processing. User Response: None required. STR6142I dsname volume ttttt/eeeee [OPEN] Explanation: This message sometimes follows message STR6141I. Strobe provides the name of the current sample dataset dsname, its volume serial number volume, and the current sample counts (ttttt total samples and eeeee execution samples). OPEN appears at the end of this message if the sample dataset is still open. System Action: Strobe continues processing. User Response: None required. STR6143I MESSAGES FOR REQUEST nnnn FOLLOW Explanation: Strobe produces this message in response to a Format 1, 2, or 3 LIST command. After this message, Strobe shows only those messages not previously listed for request number nnnn. System Action: Strobe displays messages. User Response: Read and respond to the messages. STR6144I END OF MESSAGES FOR REQUEST nnnn Explanation: Strobe produces this message after all messages have been listed in response to a Format 1 LIST command. It indicates the end of messages for request number nnnn. System Action: Strobe continues processing. User Response: None required. STR6145I STROBE USERS - active jobs Explanation: This message lists in active jobs the TSO user IDs and batch jobs that are currently using Strobe. System Action: Strobe continues processing. User Response: None required. 3-106 Strobe Messages Guide STR6147I IPL QUEUE INITIALIZATION COMPLETE - NEXT REQUEST IS nnnn Explanation: Strobe established the environment from the Strobe IPL queue dataset. Strobe recovered requests from the queue dataset. The next request number is nnnn. System Action: Strobe continues processing. User Response: None required. STR6148W Profile parameter generation failed, No value for: xxxxxxxx. STR6148W Profile parameter generation failed, Profile parm area exceeded. Explanation: Strobe encountered an error while trying to build the Reporter parameters for a WEB API profile batch job. In the first format, a parameter was encountered that had no associated value. The failing parameter is xxxxxxxx. In the second format, the working storage area for the Reporter parameters was exceeded. System Action: Strobe continues to process the profile request. In the first format, Strobe continues building Reporter parameters and will produce a formatted dump of the storage that contains the parameter values in the Strobe log.  In the second format, Strobe will produce a profile using the Reporter parameters that have been built. User Response: STR6149S Notify the Strobe system programmer. SVC nnn IN USE - TYPE t [string] Explanation: At initialization, Strobe determined that the SVC number nnn, type t, assigned in the Strobe parameter dataset appears to be in use. If the address in the SVC table points to a module with an alphanumeric string, the message provides the alphanumeric field as well. System Action: Strobe cannot establish its environment. User Response: Notify the Strobe system programmer. The Strobe system programmer must reinstall the Strobe system with an available SVC of the appropriate type, or override the SVC system-check with SVCOVR=YES parameter in the PARMLIB dataset. STR6150I STROBE ENVIRONMENT DOES NOT EXIST Explanation: The session manager responded to an environment status command or reported during session manager initialization that the Strobe environment does not exist. System Action: The Strobe environment is not created. During normal processing, Strobe will create the environment. User Response: STR6151I None required. SVC nnn UNUSED - TYPE t [string] Explanation: SVC number nnn, type t, appears to be unused. Strobe received an ENV CHECK, a SHOW, or an SVC command. The SVC number nnn, type t, assigned in the Strobe parameter dataset appears to be not used. If the address in the SVC table points to a module with an alphanumeric string, the message provides the alphanumeric field as well. System Action: Strobe initializes using the SVC specified in the Strobe parameter file. User Response: None required. STR6152E COMMAND NOT VALID -STROBE ENVIRONMENT DOES NOT EXIST Explanation: The Strobe environment was not established and a user privileged to establish it submitted a request that is not an ENV CREATE command. System Action: Strobe rejects the request. User Response: operation. Notify the Strobe system programmer who can submit an ENV CREATE STR6153S STROBE ENVIRONMENT INCOMPATIBLE - MUST BE REPLACED [ON SYSTEM sysname] Explanation: There are two copies of Strobe operating with the same fourth character in their load module names, or with the same SVC. If given, sysname identifies the system on which Strobe is running. System Action: The Strobe environment cannot be initialized. Messages Produced by Strobe 3-107 User Response: Notify the Strobe system programmer. There has probably been an installation error. STR6154I STROBE - ENVIRONMENT STATUS - CREATED AT time DATE date REQUESTS rrrr/mmmm ACTIVE aaaa/bbbb QUEUED qqqq COMPLETED cccc DEFERRED dddd AUTOMONITORED eeee BPXBATCH ffff AUTOTRAN gggg AUTOCC hhhh Explanation: Strobe issues this message in response to a STATUS command. The time of the creation of the Strobe environment is time, the date of creation, date. Strobe is maintaining rrrr requests in all (with a maximum of mmmm requests): • • • • • • • • aaaa requests are active (with a maximum of bbbb requests) qqqq are queued cccc are completed if present, dddd are deferred if present, eeee is the number of batch requests monitored by AutoStrobe if present, ffff is the number of BPXBATCH requests if present, gggg is the number of transaction requests monitored by AutoStrobe if present, hhhh is the number of transaction candidate requests monitored by AutoStrobe System Action: Strobe continues processing. User Response: None required. STR6155I ATTACH FILTER {ENABLED|DISABLED} SYSTEM= sysname Explanation: disabled. The Strobe attach filter on operating system sysname has a status of enabled or System Action: If the status is enabled, Strobe can measure all requests. If not, Strobe accepts all requests but measures active requests only. User Response: STR6156W None required. ATTACH FILTER STATUS INCONSISTENT WITH DEFAULT Explanation: The current attach filter status differs from that assigned by the Strobe parameter dataset. System Action: Strobe continues processing with the attach filter in the current status. User Response: Contact the Strobe system programmer to determine if the attach filter needs to be enabled. STR6157S STROBE ATTACH FILTER FAILED PROCESSING JOB jobname AT time date Explanation: The attach filter routine terminated abnormally while servicing the job jobname, at time time, on date date. A Strobe recovery procedure disabled the attach filter. System Action: performed. Strobe processes the job normally, but measurement requests may not be User Response: Notify the Strobe system programmer. STR6158W ENVIRONMENT REQUEST RESULTS IN NO CHANGES Explanation: Strobe already performed the requested action. The ENV operation has no effect on the current environment. System Action: Strobe continues processing but does not process this request. User Response: None required. System Action: Notify the Strobe system programmer. STR6159E STROBE AUTHORIZED COMMAND Explanation: You submitted an ENV, TEST, CLEAN, or SHOW command for which you are not authorized. System Action: Strobe continues processing but does not process this request. User Response: Notify the Strobe system programmer who has access to these commands. STR6160I ATTACH FILTER IS NOW DISABLED Explanation: Strobe successfully processed an ENV operation that disabled the attach filter. 3-108 Strobe Messages Guide System Action: Strobe accepts both active and queued requests, but measures active requests only. User Response: None required. STR6161I CSA=aaK/bbbbK/.c% ecsa=ddK/eeeeK/.f% LPA=ggggg LPB=hhh TRC=jjjj SAST=mmmmm JLST=nnnnn USSPST=ooooo DFT=ppppp ABTAB=qqqq MSGS=rrrr/sssss svc=ttt  STR6161I SRE rrrr=bbbb SREX=xxx Explanation: Strobe occupies aaK of the bbbbK of storage in the CSA, a percentage of c. In the extended CSA (ECSA), Strobe occupies ddK of eeeeK storage, a percentage of f. • • • • • • • • • The The The The The The The The The size of the Strobe SVC in ECSA is ggggg size of the Strobe SVC in CSA is hhh. size of the SVC trace table is jjjj. size of the Address Space table is mmmmm. size of the Job List is nnnnn. size of the USS Process list is ooooo. size of the Defaults table is ppppp. size of the Abend table is qqqq. number and size of Message Queue is rrrr/sssss • The Strobe SVC number is ttt.  During Strobe startup, the second form of the message may be issued. If any queued or completed requests exist, a System Request Element (SRE) was loaded into CSA for request rrrr occupying bbbb bytes. An SREX occupying xxx bytes of CSA storage may also exist. System Action: Strobe continues processing. User Response: None required. STR6162W SVC nnn IN USE - TYPE t [string] Explanation: Strobe received either an ENV CHECK or SHOW SVC command. The SVC number nnn, type t, assigned to the Strobe parameter file appears to be in use. If the address in the SVC table points to a module with an alphanumeric string, the message provides the alphanumeric field as well. System Action: Strobe displays the SVC entry. User Response: Notify the Strobe system programmer. STR6163I {CLEAN | PURGE} COMPLETE Explanation: Strobe issues this message on completion of the CLEAN operation. System Action: Strobe continues processing. User Response: None required. STR6164W Delete for request nnnn refused - measurement termination in progress Explanation: The request to delete a Strobe measurement has been refused because the termination of the measurement is still in progress. Deleting the request could cause the termination to abend. System Action: Strobe continues processing. User Response: Wait until the measurement termination has completed before attempting to delete the request. STR6165E RECOVER NOT POSSIBLE - REQUESTS ACTIVE Explanation: Strobe cannot perform an ENV RECOVER command because measurement requests are active. System Action: Strobe continues processing the active requests. User Response: command. Wait for all measurement requests to be completed and resubmit the Messages Produced by Strobe STR6166I FOLLOWING REQUESTS DELETED Explanation: Strobe processed a CLEAN operation and deleted the listed requests. System Action: Strobe continues processing. User Response: None required. STR6168I time_date 3-109 STROBE release { PARTIAL | COMPLETE } ENVIRONMENT DELETED. CREATED AT Explanation: The Strobe release environment was either partially or completely removed. The environment was created at time_date. System Action: The Strobe environment is no longer active. User Response: None required. STR6169I STROBE ENVIRONMENT IS NOW CREATED ON SYSTEM sysname [AS MEMBER OF XCF GROUP xcfgroup] Explanation: Strobe successfully created the environment on system sysname and can process all operations. If this version of Strobe is a member of a Strobe-XCF group, it can process operations initiated on another member and initiate operations for execution on other members. If present, the XCF group is named in xcfgroup. System Action: Strobe continues processing. User Response: None required. STR6170I ATTACH FILTER IS NOW ENABLED Explanation: Strobe successfully processed an ENV operation that enabled the attach filter. System Action: Strobe can measure both queued and active requests. User Response: None required. STR6171E ENVIRONMENT RECOVER REQUIRED Explanation: Strobe cannot perform an ENV CREATE command because it detected an active environment from a previous release. System Action: Strobe cannot create the new environment until the old one is deactivated. User Response: To deactivate the old environment and create the new one, issue an ENV RECOVER command. To do this, see the Strobe Installation and Customization Guide. STR6172E ENVIRONMENT RECOVER INVALID Explanation: Strobe cannot perform an ENV RECOVER command because no previous release of Strobe exists. System Action: Strobe does not change the environment. User Response: The Strobe system programmer uses the ENV RECOVER command only when replacing an old Strobe release. STR6173I OPERATING SYSTEM LEVEL IS syslvl Explanation: The operating system level is syslvl. Strobe issues this message in response to a STATUS command. System Action: Strobe continues processing. User Response: None required. STR6174S STROBE {SESSION MANAGER | SESSION REQUESTER | MEASUREMENT INITIALIZATION|MEASUREMENT SESSION| INTERFACE|SVC} ABENDED {S|U} abendcode - rsncode AT{psw addr|modname} [{modname offset|csect offset}] [SDWA NOT AVAILABLE] [{RECURSION | PERCOLATION}] Explanation: An ABEND occurred during Strobe processing. The message shows the system or user ABEND abendcode, reason code rsncode, at PSW address pswaddr, or module name modname and if available module name offset modname offset, or control section name and offset csect offset. If appropriate, SDWA (system diagnostic work area) NOT AVAILABLE displays. If present, the ABEND type is given as RECURSION or PERCOLATION. 3-110 Strobe Messages Guide System Action: The Strobe measurement task or Strobe program terminates but user tasks are unaffected. User Response: Notify the Strobe system programmer. If Strobe issued ABEND code U00000000, increase the region size of the job you are measuring and resubmit the request. STR6175S R0-R7= addr0 addr1 addr2...addr7 R8-RF= addr8 addr9 addrA...addrF addr [key data] addr [key data]... Explanation: An ABEND occurred in the Strobe system. The contents of registers 0 through 15 appear in fields addr0 through addrF. Subsequent lines addr key data display the contents of storage pointed to by the PSW (program status word) for a length of X’50’, followed by the contents of the storage pointed to by the registers. If accessible, the key field shows the protection key, and the data field dumps X’ 10’ (32 bytes) of the area addressed by the registers. Strobe lists these lines in the Strobe log only. System Action: Strobe continues processing. User Response: Contact Compuware Customer Support. This information is provided for diagnostic purposes. STR6176S SDWAFLAGS flags translation Explanation: An ABEND occurred in the Strobe system. The values of the ABEND flags from the system diagnostic work area (SDWA), flags, appear with the translation of those flags, translation. This message appears in the Strobe log only. System Action: Strobe continues processing. User Response: Contact Compuware Customer Support. This information is provided for diagnostic purposes. STR6177S SA - {FWD | BKWD} data Explanation: An ABEND occurred in the Strobe system. The data will be split across several lines and will consist of:  RT3 reserved ptr-pre ptr-next R14 R15 R0 entryname R1 R2.... R12,   where “R0.... R15“are register contents. reserved is an IBM field. ptr-prev is a pointer to the previous save area. ptr-next is a pointer to the next save area. This message appears in the Strobe log only. System Action: Strobe continues processing. User Response: Contact Compuware Customer Support. STR6178S PSW [FROM {SDWA | PRB | IRB | SVRB}] [AT ERROR] [sdwapsw|prbpsw| irbpsw|svrbpsw] Explanation: An ABEND occurred in the Strobe system. The PSW (program status word) at the time of the error appears in one of the following: sdwapsw, the SDWA (system diagnostic work area), or prbpsw, the PRB (program request block), or irbpsw, the IRB (interruption request block), or svrbpsw, the SVRB (supervisor request block). Message STR6182S displays the module, control section, or entry at the time of the error. System Action: Strobe continues processing. User Response: Contact Compuware Customer Support. STR6179S TYPE PSW R15 R00 tttt psw r15 r0 CP ASID TCB TIME cc aaaa time tcb R01 RE r1 rr Explanation: An ABEND occurred in the Strobe system. Strobe displays the trace table, listing the type of entry (tttt), the PSW (program status word), psw, the contents of registers 15, 0, and 1 (r15, r0, r1), RE a reserved field (rr), the CP id (cc), the ASID, (aaaa), the TCB (task control block address), tcb, and the time (time). This message appears in the Strobe log only. Messages Produced by Strobe System Action: Strobe continues processing. User Response: Contact Compuware Customer Support. STR6180I AT offset] 3-111 MODULE modname AT modaddr(modlen) FROM source [ABENDS = num LAST IS abendcode Explanation: ABENDs occurred in the Strobe system. The load module named modname at the address modaddr with length modlen was loaded from the load library with the dataset name or data definition name and concatenation number identified in source. If present, the number of ABENDs is num, the ABEND code of the last ABEND is abendcode, and its offset is offset. System Action: Strobe continues processing. User Response: None required. STR6181I {MODULE | CSECT} csectname AT csaddr(cslen) > R=release PTF=FS000000 Explanation: An ABEND occurred in the Strobe system. The control section named csectname at the address csaddr with length cslen has a release number release. The last assembly date was assembly date and the PTF level was FS######. System Action: Strobe continues processing. User Response: None required. STR6182S {MODULE|CSECT|ENTRY} name AT addr OFFSET offset - string Explanation: An ABEND occurred in the module, control section, or entry name, located at addr. The site of the ABEND was at offset offset. The module, control section, or entry contains the phrase string. System Action: Strobe continues processing. User Response: None required. STR6183S SVCDUMP - RC=rc - REQUEST nnnn Explanation: Request nnnn specified that Strobe perform an SVCDUMP. The return code from the SVCDUMP request is rc. Depending upon the return code, the dump may reside in the system dump dataset. System Action: Strobe requests an SVC for the measured address space. User Response: To process the dump according to your installation’s standards, contact the Strobe system programmer. STR6185I MODULE TRACKING TABLES FOR REQUEST NOT AVAILABLE Explanation: Strobe deleted the module tracking tables for the specified request from storage. They are no longer available for display. System Action: Strobe continues processing. User Response: None required. STR6186S SESSION MANAGER MUST BE ACTIVE BEFORE USING STROBE Explanation: The Strobe address space was not started. System Action: The Strobe address space was not available when this message was issued. Strobe services are not available unless the Strobe address space is started. User Response: STR6187E Notify the Strobe system programmer to start the Strobe address space. commandname COMMAND REJECTED BY ACCESS CONTROL EXIT Explanation: A Strobe user exit rejected the command commandname. System Action: Strobe rejects the requested command. User Response: See the system programmer responsible for the Strobe user-exit facility. STR6187E commandname COMMAND REJECTED ACCESS CONTROL EXIT NOT FOUND Explanation: A Strobe user exit rejected the command commandname because the exit module STRBCXAC was not found in the address space. 3-112 Strobe Messages Guide System Action: Strobe rejects the requested command. User Response: Restart the Strobe ISPF session to force the exit to be reloaded. STR6188E MEASUREMENT SESSION INITIALIZATION REJECTED BY ACCESS CONTROL EXIT Explanation: A Strobe user exit rejected the measurement session initialization request. System Action: Strobe cannot accept the measurement request. User Response: See the system programmer responsible for the Strobe user-exit facility. STR6189I {STR6189I|STR6189W| STR6189E| STR6189S} user exit message text Explanation: A Strobe user exit rejected an operation or a measurement session initialization request. user exit message text gives the message returned by the user exit facility; the error severity indicator (I, W, E or S) depends on the returned message. System Action: Strobe does not process the request because the user exit rejected it. User Response: Correct and resubmit the request. STR6190W STROBE LOG DATA SET IS nnn% FULL Explanation: The Strobe log filled nnn% of its allocated space. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. STR6191E STROBE LOG DATA SET IS FULL Explanation: System Action: All of the allocated extensions on the Strobe log are used. Strobe terminates processing. User Response: Notify the system programmer. To continue processing, the system programmer must either clear the log with the LOG CLEAR command or backup and clear the log with Strobe Log (STRBCLOG) Utility. STR6192E INTERNAL ERROR - ddname NOT OPEN Explanation: Strobe expects the DDNAME ddname to be open, but it is not. System Action: Strobe may not process the current command or request, or all processing may terminate depending upon the severity of the error. User Response: STR6193I Notify the Strobe system programmer. ddname DATA SET - dsname IS percent % FULL Explanation: The name of the dataset referred to by ddname is dsname, and it is percent percent full. System Action: command. Strobe issues this message in response to a STATUS or SHOW QUEUE User Response: None required. STR6194I LOG DATA SET - dsname IS percent % FULL [WITH nn EXTENTS] Explanation: The name of the current Strobe log is dsname. It is percent percent full, and, if this value is provided, it has nn extents. System Action: Strobe continues processing. User Response: None required. STR6195S RECENTLY REFERENCED SRE FOLLOWS Explanation: Strobe terminated abnormally and displays the last active Strobe request element (SRE). System Action: Strobe continues processing. User Response: Review the ABEND message and resubmit the request. If the problem occurs again, notify the Strobe system programmer. Messages Produced by Strobe STR6196S 3-113 STROBE ABEND RECOVERY COMPLETE - {TERMINATING|CONTINUING} Explanation: Strobe experienced an ABEND. System Action: Strobe continues or terminates as stated in the message. User Response: Strobe. Contact the Strobe system programmer to correct the problem and restart STR6197E Strobe of Changeman address space is not supported Explanation: Strobe encountered a request to measure an address space that is running the Changeman Audit program. Strobe cannot measure such an address space because of a conflict with the tasking structure. System Action: Strobe rejects the measurement request. This message follows STR6203E, which gives the jobname and session initialization time. User Response: STR6198I SRC= src TMI= tmi OPC= opc SMI= smi Explanation: • • • • None required. This message is generated by internal tracing that Compuware has initiated. src is the number of session requester calls the session manager has received. tmi is the number of timer interrupts that the session manager has received. opc is the number of operator commands that the session manager has received. smi is the number of SMI interrupts in the session manager. System Action: User Response: STR6199E Strobe continues processing. Your Compuware systems engineer will determine any further action. STROBE HAS EXPIRED REQUEST DENIED Explanation: expired. The session manager determined that the current version of the Strobe system System Action: Strobe will allow you to list or delete requests, but it will not allow you to add requests. Strobe will not process any requests that are queued. User Response: STR6200I Notify the Strobe system programmer. STROBE MEASUREMENT SESSION INITIALIZED FOR JOB jobname AT time date Explanation: Strobe started a measurement session for job jobname at time time and date date. System Action: Strobe continues processing. User Response: None required. STR6201I STROBE MEASUREMENT SESSION COMPLETED FOR JOB jobname AT time date Explanation: date. Strobe completed a measurement session for job jobname at time time and date System Action: Strobe continues processing. User Response: None required. STR6202I STROBE ATTACH FILTER PROCESSING FOR REQUEST nnnn STOPPED ON SYSTEM sysname - REQUEST ALREADY ACTIVE ON SYSTEM sysname Explanation: The attach filter for system sysname determined there is a measurement request (request nnnn) associated with a job step that is about to start, and attempted to initiate the measurement. However, another member of the Strobe-XCF group is already measuring the request. This message appears in the Strobe log only. System Action: Strobe terminates processing for request rrrr on system sysname. User Response: None required. 3-114 Strobe Messages Guide STR6203E date STROBE MEASUREMENT SESSION INITIALIZATION FAILED FOR JOB jobname AT time Explanation: Strobe failed to initialize a measurement session for job jobname at time time and date date. Accompanying messages, including STR6197E, STR6206E, STR6210E, STR6215E, STR6216E, and STR6221E, provide additional information. System Action: Strobe stops processing the request. User Response: If the request was for an unsupported address space there is no response required; otherwise resubmit the measurement request. If the problem persists, notify the Strobe system programmer. STR6204E STEP IS IN ALLOCATION Explanation: initiator. You submitted a request for a job step that is still controlled by the MVS System Action: Strobe cannot measure the job step. User Response: Resubmit the request after the job step completes allocation. STR6205E LIMITED FUNCTION ADDRESS SPACE Explanation: The target program is running in a limited function address space. The operating system does not provide the functions that Strobe requires for its operation. System Action: Strobe cannot measure limited function address spaces. User Response: None required. STR6206E STROBE INITIALIZATION SRB DID NOT COMPLETE - STEP=stepname PGM=pgmname REASON=reason TCBFLAGS=tcbflags Explanation: The Strobe initialization service request block (SRB) for step stepname, program pgmname did not complete. The reason is given in reason. The TCB flag values given in tcbflags are defined in the IBM z/OS MVS Data Areas Manual. System Action: Strobe does not process the request. User Response: Resubmit the measurement request. If the problem persists, notify the Strobe system programmer. STR6207E IRB WAS NOT DISPATCHED Explanation: Strobe attempted to implant itself into a user address space to start a measurement, but the IRB (Interrupt Request Block) scheduled by the Strobe SRB did not complete. System Action: Strobe canceled the IRB, so the measurement request did not start. User Response: Determine why the IRB could not be dispatched or could not complete in the target address space and correct, if possible. It is also possible that the situation was a temporary one, and a repeat ADD command might implant Strobe successfully. STR6209I COBOL II DETECTED Explanation: Strobe detected that the COBOL II environment is active. System Action: Strobe continues processing. User Response: None required. STR6210E Strobe of HSC address space is not supported Explanation: Strobe encountered a request to measure an address space that is running Storage Tech’s HSC system. Strobe cannot measure such an address space because of a conflict with the tasking structure. System Action: Strobe rejects the measurement request. This message follows STR6203E, which gives the jobname and session initialization time. User Response: None required. Messages Produced by Strobe STR6211E 3-115 INSUFFICIENT AVAILABLE MEMORY Explanation: The Strobe measurement session cannot be initialized because of insufficient virtual storage. The Strobe measurement task requires 300K of storage in the extended private address space. Each of the Strobe options has additional storage requirements. See the Strobe Installation and Customization Guide for the virtual storage requirements of Strobe and Strobe options. System Action: terminates. The Strobe environment is still available, but the measurement request User Response: Notify the Strobe system programmer. STR6212E TOO MANY ACTIVE REQUESTS Explanation: The number of active measurement requests on the Strobe system exceeded the maximum set at system installation. System Action: Strobe cannot process additional requests. User Response: Notify the Strobe system programmer. STR6213I PROGRAM progname DETECTED - alias USED Explanation: Strobe detected a program whose name on the EXEC PGM= statement (progname) begins with a recognized alias for CICS, IMS, or CA-IDMS. System Action: Strobe invokes module STRBCRB using the alias alias: DFHBCRB for CICS programs, DFSBCRB for IMS programs, and IDMBCRB for CA-IDMS programs. User Response: STR6214E None required. STROBE INITIALIZATION IRB DID NOT COMPLETE - REASON=text Explanation: The Strobe initialization processing under an IRB (Interruption Request Block) did not complete. The system-supplied reason is in text. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR6215E Strobe of MIM address space is not supported Explanation: Strobe encountered a request to measure an address space that is running the MIM program. Strobe cannot measure such an address space because of an enqueue-handling conflict with MIM. System Action: Strobe rejects the measurement request. This message follows STR6203E, which gives the jobname and session initialization time. User Response: STR6216E None required. Strobe of HSM address space is not supported Explanation: Strobe encountered a request to measure an address space that is running IBM’s DFHSM program. Strobe cannot measure such an address space because of conflicts with CA Technologies’ TMS program. System Action: Strobe rejects the measurement request. This message follows STR6203E, which gives the jobname and session initialization time. User Response: STR6217E None required. SESSION MANAGER NOT ACTIVE Explanation: System Action: The session manager is not active. Strobe does not measure the current job. User Response: Notify the Strobe system programmer to restart the session manager and resubmit the request. STR6218E OPTIONS=NOQUIT REQUIRED Explanation: Strobe detected a situation in which the Strobe measurement task must be attached as a job step task because the measured program already has job step tasks. The ADD operation did not specify the OPTIONS=NOQUIT operand, and the JSTCB parameter defined at 3-116 Strobe Messages Guide Strobe installation either requires the OPTIONS=NOQUIT operand or disallows measurement of such jobs. System Action: Strobe rejects the measurement request. User Response: If the Strobe system programmer specified JSTCB=ALLOW in the Strobe parameter file, resubmit the request, and specify OPTIONS=NOQUIT. STR6219W NOQUIT OPTION IN EFFECT Explanation: Strobe added a measurement request for a job. The Strobe measurement task is attached as a job step task because the measured job attached its tasks as job step tasks. You cannot issue a QUIT command to this request, and the Strobe environment cannot be deactivated until the measurement task terminates. System Action: Strobe continues processing. The measurement task remains in the target address space and does not terminate until the address space terminates. User Response: To stop sampling, issue a STOP command. Strobe will close the sample dataset and enter the wait state. The measurement task will terminate when the job step terminates. STR6220W OPTIONS=NOJSTCB USED - {TSO|VIO STEPLIB|VIO|TCAM}- ENCOUNTERED Explanation: Strobe cannot attach the user program as a job step task because of compatibility problems with TSO, VIO STEPLIB, VIO, or TCAM. System Action: Strobe attaches the user program as a step task. User Response: None required. STR6221E Strobe of MSAS address space is not supported Strobe of C:D address space is not supported Strobe of TN3270 address space is not supported Change Data Capture addrsp is not supported  Fork or Spawn in progress is not supported Explanation: Strobe encountered a request to measure an address space that is not supported. Strobe cannot measure this address space due to environmental issues. System Action: Strobe rejects the measurement request. This message follows STR6203E, which gives the jobname and session initialization time. User Response: STR6222S None required. SESSION MANAGER IS STILL INITIALIZING Explanation: System Action: The Strobe address space has not yet completed initialization. The Strobe address space is not yet available. User Response: The time required for Strobe initialization depends upon a number of factors including the number of requests that exist at initialization and system performance. Strobe will be available once initialization completes. If this message persists, notify the Strobe system programmer. STR6223E DATA SET NAME PREFIX IS LARGER THAN 26 CHARACTERS Explanation: characters. The dataset name prefix entered in the Strobe parameter file is larger than 26 System Action: The session manager startup terminates with an error after processing the Strobe parameter file. User Response: Contact the Strobe system programmer to correct the error and restart the session manager. STR6224E INVALID EXPIRATION DATE SPECIFIED Explanation: The expiration date specified in the Strobe parameter dataset is invalid. System Action: The session manager startup terminates with an error after processing the Strobe parameter file. User Response: Notify the Strobe system programmer to correct the error and restart the session manager. Messages Produced by Strobe STR6225I 3-117 DCB=(RECFM=VB, LRECL=137, BLKSIZE=blksize) Explanation: Strobe displays the data control block (DCB) characteristics of the Strobe log. The record format (RECFM) is VB (variable block), the record length (LRECL) is 137, and the block size BLKSIZE) is blksize. System Action: Strobe continues processing. User Response: None required. STR6226I SPACE= (alloc units, (xxxx,yyyy)) Explanation: Strobe displays the current space allocation of the Strobe log. alloc units can be block size (BLK), track (TRK), or cylinders (CYL). Primary allocation is xxxx, and secondary allocation is yyyy. This message is followed by STR6229I. System Action: Strobe continues processing. User Response: None required. STR6227I NUMBER OF EXTENTS USED nn Explanation: Strobe displays the current number of allocation extents, nn, used by the Strobe log. System Action: Strobe continues processing. User Response: None required. STR6228I LOG HISTORY Explanation: If the log dataset is a generation data group, Strobe will display a history of the last ten Strobe logs used. This message is followed by STR6229I. System Action: Strobe continues processing. User Response: None required. STR6229I dsname START TIME=(time date) Explanation: Strobe displays the Strobe log name dsname followed by the start time time and start date date. System Action: Strobe continues processing. User Response: None required. STR6230S STROBE SESSION REQUESTER ALREADY ACTIVE Explanation: For the current job or user, the session requester is already active. The session requester determined that there is another copy of the session requester active in the current address space. System Action: The second copy of the session requester terminates with a return code of 12. User Response: STR6231I You are already in an active TSO session. Continue using the active session. NUMBER OF {CA|CI} SPLITS nnn Explanation: System Action: Strobe displays the number nnn of CA or CI splits in the queue dataset. Strobe continues processing. User Response: Use these VSAM statistics to guide you in optimizing the efficiency of the VSAM environment. STR6232I NUMBER OF RECORDS IN QUEUE nnn Explanation: System Action: Strobe displays the number, nnn, of records in the queue dataset. Strobe continues processing. User Response: Use these VSAM statistics to guide you in optimizing the efficiency of the VSAM environment. 3-118 Strobe Messages Guide STR6233I LAST USED RBA rba1 HIGH ALLOC RBA rba2 Explanation: Strobe displays the last used relative block address (RBA), rba1, and the high allocated RBA, rba2, in the VSAM queue dataset. System Action: Strobe continues processing. User Response: Use these VSAM statistics to guide you in optimizing the efficiency of the VSAM environment. STR6234I NUMBER OF xxxxxxxx yyyyyyyy Explanation: Strobe displays the number (yyyyyyyy) of inserts, updates, or deletes (xxxxxxxx) to the queue dataset. System Action: Strobe continues processing. User Response: Use these VSAM statistics to guide you in optimizing the efficiency of the VSAM environment. STR6235I FREE SPACE (BYTES) xxx Explanation: The amount of FREE SPACE in bytes available in the current queue allocation is xxx. System Action: Strobe continues processing. User Response: None required. STR6239I PROCESSING FOR ENV commandname {INITIATED | COMPLETED} Explanation: The processing for command commandname has initiated, or it has completed. System Action: None. User Response: None required. STR6240I ABEND abendtype abendcode - rsncode AT {modname |pswaddr} - [modoffset - csectname csectoffset] jobname (asid) time date {UDUMP | ABEND| MDUMP| SDUMP} {PERC|RECUR} Explanation: This message lists the history of ABENDS from which Strobe recovered since the last time the session manager was started. The type of ABEND abendtype, the system or user ABEND code abendcode, and reason code rsncode are followed by the name of the module modname or the address of the program status word pswaddr. If available, the offset of the module modoffset, the name of the control section csectname and the offset of the control section csectoffset appear. Strobe then records the job name jobname (asid) at time time on date date. Strobe action is one of the following: UDUMP, ABEND, MDUMP, or SDUMP. Then either PERC or RECUR appear. System Action: The Strobe measurement task or Strobe program terminates but user tasks are unaffected. User Response: Notify the Strobe system programmer to contact Compuware Customer Support. Have the Strobe log available when calling in the trouble report. STR6241I NO ABENDS DETECTED Explanation: Strobe detected no ABENDs in the system since the last time the session manager was started. System Action: Strobe continues processing. User Response: None required. STR6242E QUEUE PROCESSING ERROR - MAX REQUESTS nnn QUEUED REQUESTS READ mmm Explanation: During session manager startup, Strobe encountered more requests on the queue dataset mmm than the number defined by the MAX REQUESTS parameter nnn in the Strobe defaults. System Action: Strobe terminates. User Response: Notify the Strobe system programmer. The Strobe system programmer must increase the Strobe defaults to allow for the number of requests to be read from the queue. Messages Produced by Strobe 3-119 STR6243S STROBE INITIALIZATION TERMINATED - ENVIRONMENT DOES NOT SUPPORT USE OF XCF GROUPS Explanation: You specified the XCFGROUP= parameter in the Strobe parameter dataset so that you can join the Strobe-XCF group. Your version of the MVS operating system, however, does not support use of Strobe-XCF groups. To use Strobe-XCF groups, the system must be at MVS/ESA V4R1 or higher. System Action: Strobe terminates initialization. User Response: Notify the Strobe system programmer. STR6244S STROBE INITIALIZATION TERMINATED - UNABLE TO JOIN STROBE-XCF GROUP text Explanation: Strobe could not join the Strobe-XCF group. One of the following statements appears in text: – – – – – INVALID GROUP NAME IN INSTALLATION PARAMETERS DUPLICATE STROBE-XCF MEMBER NAME SYSPLEX HAS MAXIMUM NUMBER OF XCF GROUPS STROBE ERROR DURING function PROCESSING XCF ERROR DURING JOIN PROCESSING RETURN CODE rc REASON CODE rsnc System Action: Strobe terminates initialization. User Response: In the first case, examine and change the specification for the XCFGROUP parameter. In the last four cases, notify the Strobe system programmer. STR6245S STROBE INITIALIZATION TERMINATED - UNABLE TO COMMUNICATE WITH STROBEXCF GROUP Explanation: Strobe could not communicate with the other Strobe-XCF group members once it had joined the Strobe-XCF group. System Action: Strobe terminates initialization. User Response: Notify the Strobe system programmer. STR6246S STROBE INITIALIZATION TERMINATED - {QUEUE DATA SET NAME|MESSAGE DATA SET NAME| RELEASE LEVEL| VERSION CHARACTER} DOES NOT MATCH STROBE-XCF GROUP Explanation: One or more of the following values does not match the corresponding value for the Strobe-XCF group: • • • • Dataset name for queue Dataset name for message Release level Version character System Action: Strobe terminates initialization. User Response: Notify the Strobe system programmer. STR6247I PARAMETER(S) parameter1, parameter2, parameter3, CHANGED TO value1, value2, value3, TO MATCH STROBE-XCF GROUP VALUES Explanation: Strobe changed the values that you specified for the named parameter(s) parameter1, parameter2, parameter3, to the values specified in value1, value2, value3. The values were changed to conform to the values that the Strobe-XCF group uses. In a multisystem environment, these values must be the same among all members of the group. System Action: Strobe continues initialization. User Response: None required. STR6248E commandname COMMAND PROCESSING TERMINATED - ERROR DURING fnctname PROCESSING Explanation: Strobe terminated processing for command commandname because it experienced an error while processing the internal function, subroutine, or value indicated in fnctname. System Action: Strobe does not process the command. User Response: Notify the Strobe system programmer. 3-120 Strobe Messages Guide STR6249W REQUEST FOR JOB jobname MAY NOT BE QUEUED TO SYSTEM sysname INSUFFICIENT ACCESS AUTHORITY Explanation: Your job jobname may not be queued on system sysname (one of the systems to which you targeted the request) because the security data base of the system on which you entered the request indicates that you are not authorized to measure the job on the system. System Action: request. Strobe still routes this request to all systems to which you targeted the The security data bases of those systems will check your authorization. If Strobe finds one or more systems on which you are authorized to measure job jobname, Strobe will queue the request on those systems. User Response: To measure a job on any specific system, the Strobe system programmer or security administrator must grant you access to the system in its security data base. The Strobe system programmer may want to change the systems on which you are authorized to submit measurement requests. STR6250I [text,] [rel,] [lvl,] [volser] Explanation: This message lists information in response to a SHOW DEFAULTS command. In text it provides default values supplied through the parameter file and currently in storage. In addition it can display: the current release of Strobe (rel), the Strobe PTF level (lvl), and the Strobe tape volume serial number (volser). System Action: None. User Response: None required. STR6251W REQUEST DELETED BEFORE AUTOMATIC PERFORMANCE PROFILE SUBMISSION ROUTINE CALLED Explanation: The completed request that stipulated automatic creation of a Performance Profile has been deleted. System Action: Strobe does not process the request. User Response: the request. To obtain an automatically created Performance Profile, you must resubmit STR6252E AUTOMATIC PERFORMANCE PROFILE COULD NOT BE CREATED error reason Explanation: The Performance Profile could not be automatically created. error reason is one of the following: • • • • The internal variable SESSID is invalid. The internal variable SAMPDSN is invalid. The sample dataset name sdsname is invalid. ACEEUSRI is invalid. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. If you require further assistance, contact Compuware Customer Support. STR6253W PERFORMANCE PROFILE JCL CONTAINED UNRECOGNIZED TOKEN token Explanation: token. Strobe was unable to recognize and could not substitute a value for the token System Action: Depending upon the nature of the error, Strobe may or may not produce a Performance Profile. User Response: Verify the JCL used and resubmit the request. STR6254E AUTOMATIC PROFILE CREATION COULD NOT BE COMPLETED. {TOKEN NOT FOUND} {TOKEN NOT FOUND} Explanation: The Performance Profile could not be automatically created because either SAMDSN or PRINTDSN could not be found. System Action: Strobe does not process the request. User Response: Verify the JCL used and resubmit the request. Messages Produced by Strobe STR6255E 3-121 INTRDR DYNAMIC ALLOCATION FAILED RC= rc ERC/IRC= erc/irc Explanation: Strobe could not allocate the internal reader dataset. The return code is rc, the error reason code is erc, and the information reason code is irc. System Action: The requested Strobe command fails. Depending upon the nature of the error, Strobe may or may not continue processing. User Response: STR6256E Notify the Strobe system programmer. INTRDR OPEN FAILED. RC = rc Explanation: Strobe could not open the internal reader. The return code is rc. System Action: Strobe does not process the request. User Response: Support. Save the contents of the Strobe log and contact Compuware Customer STR6257I JCL SUBMITTED FOR AUTOMATIC PROFILE CREATION Explanation: submitted. The JCL for creating a Performance Profile automatically has been successfully System Action: Strobe processes the request. User Response: None required. STR6258S yyyy/zzzz SESSION REQUESTER ABEND RECOVERY COMPLETE - {TERMINATING | CONTINUING} Explanation: Strobe experienced an ABEND. yyyy is the amount of stack space used. zzzz is the amount of stack space allocated. System Action: Strobe continues or terminates, as stated in the message. User Response: Contact the Strobe system programmer to correct the problem. STR6259S yyyy/zzzz SESSION MANAGER ABEND RECOVERY COMPLETE - {TERMINATING | CONTINUING} Explanation: Strobe experienced an ABEND. yyyy is the amount of stack space used. zzzz is the amount of stack space allocated. System Action: Strobe continues or terminates, as stated in the message. User Response: Contact the Strobe system programmer to correct the problem. STR6260E REQUEST nnnn COMPLETE - CHANGE NOT VALID Explanation: You submitted a CHANGE operation for measurement request nnnn, but that request has already terminated. For a completed request, only a CHANGE operation with RETAIN=COMPLETE=rrr is valid, where rrr is the number of days the request is to be retained. System Action: Strobe does not process the request. User Response: None required. STR6261I {request|element} nnnn jobname STEP=stepname CREATED=date time [expiration] [groupname] parameters Explanation: Strobe displays request information: • In response to a LIST, ADD, CHANGE, SEND or DELETE command, Strobe displays details of the request. • In response to a LISTGRP command submitted with a AutoStrobe request group name parameter, Strobe displays details of the elements in that request group. System Action: None. User Response: None required. STR6262I {qname rname}| {GQSCAN-INCOMPLETE}| {GQSCAN-RC=rc} Explanation: For qname rname, Strobe listed a resource’s major name qname and minor name rname in response to a SHOW ENQUEUES command. For GQSCAN-INCOMPLETE, the IBM MVS service GQSCAN issued an incomplete list of resource major names qnames and minor 3-122 Strobe Messages Guide names rnames in response to a SHOW ENQUEUES command. For GQSCAN-RC=rc, the IBM MVS service GQSCAN issued a return code of rc in response to a failed SHOW ENQUEUES command. System Action: None. User Response: For qname rname, the command executed successfully and no response is required. For GQSCAN-INCOMPLETE, the command executed unsuccessfully. Resubmit the SHOW ENQUEUES command to view the entire list of resource major names qnames and minor names rnames. For GQ-SCAN- RC=rc, refer to the IBM z/OS MVS Programming Authorized Assembler Services Reference volumes for an explanation of the return codes’ meanings. STR6263I asid jobname stepname stepname progname - ATTACH FILTER INFO Explanation: This message is issued when a program for which there is an Add Queued request executes. The job to be measured with Strobe is identified by its address space identifier asid, job name, jobname, and step names, stepname. The name of the program that requests Strobe measurement is given in progname. System Action: None. User Response: None required. STR6264E SEND COMMAND FAILED - PREVIOUS SEND IN PROGRESS FOR REQUEST nnnn Explanation: The SEND command that you issued failed because a SEND command has already been issued for request nnnn. System Action: Strobe does not process the request. User Response: Wait until the previous SEND command has completed. Check the Strobe log for additional messages. STR6265E REQUIRED POSITIONAL PARAMETER MISSING Explanation: System Action: A positional parameter that is required for the command is missing. Strobe does not process the request. User Response: Reissue the command using the correct required positional parameter. For the correct syntax for the command, refer to “Measuring with Strobe Command Language” in the Strobe User Guide. STR6266I GROUP groupname, GRPOWNER=grpowner Explanation: This message is issued in response to a LISTGRP command that specifies the group name. It identifies the name of the group and will always be followed by STR6261I. System Action: None. User Response: None required. STR6267E THE KEYWORD USER IS REQUIRED ON THE JOB STATEMENT Explanation: JCL. The keyword USER and the associated value is missing from the job statement System Action: Strobe will not process the request. User Response: Notify your Strobe system programmer. STR6268E THE JOB STATEMENT KEYWORD USER VALUE DOES NOT MATCH THE ACTUAL USER Explanation: The value for the keyword USER on the job statement is not valid because it does not match the user’s user ID. System Action: Strobe does not process the request. User Response: Specify the user’s user ID and resubmit the job statement. STR6269E THE JOB STATEMENT SPECIFIED CONTAINED A PASSWORD KEYWORD Explanation: The job statement contained a PASSWORD keyword. For security reasons, this parameter is not allowed on the job statement. System Action: Strobe does not process the request. User Response: Resubmit the job statement and do not use the PASSWORD keyword. Messages Produced by Strobe STR6270E 3-123 routine - QUEUE DELETE FAILED. RC rc RSNC rsnc Explanation: An error occurred while routine routine was attempting to delete a record from the queue dataset. The VSAM return code is rc, and the VSAM reason code is rsnc. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. STR6271E routine - QUEUE READ FAILED - RC rc RSNC rsnc Explanation: An error occurred while routine routine was attempting to read a record on the queue dataset. The VSAM return code is rc, and the VSAM reason code is rsnc. System Action: The session manager terminates. User Response: Notify the Strobe system programmer. STR6272E routine - QUEUE UPDATE FAILED: RC rc RSNC rsnc Explanation: An error occurred while routine was attempting to update a record on the queue dataset. The VSAM return code is rc, and the VSAM reason code is rsnc. System Action: User Response: STR6273I The session manager terminates. Notify the Strobe system programmer. jobname (jobidentifier) SUBMITTED FOR AUTOMATIC PROFILE CREATION Explanation: The JCL with jobname for creating a Performance Profile automatically has been successfully submitted and assigned the job identifier jobidentifier. System Action: Strobe processes the request. User Response: None required. STR6274E routine - QUEUE OPEN FAILED - RC rc RSNC rsnc Explanation: An error occurred while routine was attempting to open a record on the queue dataset. The VSAM return code is rc, and the VSAM reason code is rsnc. System Action: The session manager terminates. User Response: Notify the Strobe system programmer. STR6275E LOG HISTORY PROCESSING FAILED - RC rc RSNC rsnc Explanation: An error occurred while Strobe attempted to read or write to the Strobe log measurement session history record on the queue dataset. The return code is rc, and the reason code is rsnc. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. STR6276E SESSION MANAGER FUNCTION ERROR - ROUTINE routinename FUNCTION fnctcode SMRC smrc FRC fntrc Explanation: An error occurred in the session manager while processing a request. The routine that detected the error is given in routinename. The function code for the request that was being processed when the error occurred is given in fnctcode. The return code from the session manager is smrc, and function return code is fntrc. System Action: Depending on the severity and nature of the error, Strobe will continue processing the request or terminate the request. User Response: Note the error messages that Strobe returns to your terminal and check the Strobe log for additional messages associated with the request number. Take action based on this information. For more information on the cause of the error, determine the definition of the function code, given in fnctcode, by referencing it in the section entitled “Function Codes Returned by Strobe Session Manager” in Chapter 5, “Abend Codes Returned by Strobe”. STR6277E LOG DATA SET IS NOT IN A GENERATION DATA GROUP. PLEASE USE COMMAND LOGCLEAR TO CLEAR LOG DATA SET Explanation: You entered a LOGSWITCH command for a nongeneration data group (nonGDG) log dataset. 3-124 Strobe Messages Guide System Action: Strobe does not process the request. The LOGSWITCH command is invalid for a non-GDG log dataset. User Response: Use the LOGCLEAR command or the Strobe log utility STRBCLOG to clear the current Strobe log. STR6278E LOG DATA SET IS IN THE GENERATION DATA GROUP. PLEASE USE COMMAND LOGSWITCH TO SWITCH LOG DATA SET Explanation: You entered the LOGCLEAR command for a generation data group (GDG) log dataset. The LOGCLEAR command is invalid for a GDG log dataset. System Action: Strobe continues processing. User Response: Use the LOG SWITCH command rather than the LOGCLEAR command. STR6279I LOGCLEAR COMPLETE - SYSLOG DATA SET HAS BEEN CLEARED Explanation: used. The LOGCLEAR command executed. The Strobe log is cleared and ready to be System Action: Strobe continues processing. User Response: None required. STR6280E ISPF REENTRY WITHOUT INIT CALL Explanation: System Action: Strobe encountered an internal error while processing an ISPF request. Strobe terminates processing the request. User Response: Exit from Strobe to ISPF, and then reinvoke Strobe from the ISPF PRIMARY OPTIONS panel. If the problem persists, notify the Strobe system programmer. STR6282E BLDL FAILED FOR MODULE modname Explanation: System Action: Strobe detected an internal error while trying to locate the module modname. Strobe terminates abnormally, with ABEND code 620-4. User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6283E INTERNAL ERROR modname NOT FOUND Explanation: System Action: Strobe detected an internal error while trying to locate the module modname. Strobe terminates abnormally, with user ABEND code 610-5. User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6284E INTERNAL ERROR INVALID PARAMETER LIST PASSED TO LOGSUB RTN Explanation: System Action: Strobe detected an internal error while processing a parameter list. Strobe terminates abnormally, with user ABEND code 610-6. User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6285E INTERNAL ERROR INVALID RETURN FROM QREC RTN Explanation: Strobe detected an internal error while processing a request. System Action: If this error occurs during Strobe initialization, the request is deleted and initialization continues. In other cases, Strobe terminates abnormally, with user ABEND code 610-7. User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6286E ATTACH FILTER ENABLED DURING REMOVE ENV PROCESSING Explanation: System Action: Strobe detected an internal error while processing an ENV REMOVE request. Strobe terminates abnormally, with user ABEND code 610-8. Messages Produced by Strobe 3-125 User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6289E INTERNAL LOGIC ERROR SEARCHING SVC TABLE Explanation: System Action: Strobe detected an internal error while searching the SVC table. Strobe terminates abnormally, with user ABEND code 610-10. User Response: Examine the ABEND output accompanying this message for more information. Notify the Strobe system programmer. STR6290E SYSTEM SERVICE FAILED (sysserve) ddname - RC=rc [erc] Explanation: The system service sysserve for ddname ddname failed. The return code is rc, and the reason code, if given, is erc. System Action: If OPEN fails for the SYSQUEUE dataset, Strobe terminates abnormally with user ABEND code 610-9. User Response: STR6291E Notify the Strobe system programmer. DATA SET NOT ALLOCATED - ddname Explanation: System Action: The dataset with data definition name ddname is not allocated. Strobe cannot find the dataset and does not process the request. User Response: If the message shows STRMTLIB as the unallocated ddname, then your installation may be set up to run Strobe out of an APF-authorized load library, but the target jobstep (or user ID) did not correctly allocate that load library. Verify that the target jobstep correctly allocates the APF-authorized load library and retry the job. If the error persists, notify the Strobe system programmer. STR6292E OPEN FOR ddname1(ddname2) FAILED Explanation: The data definition name for the dataset with logical name ddname1 and true ddname ddname2 cannot be opened. System Action: Strobe may terminate. User Response: Check the data definition statements to ensure that Strobe is trying to open the correct dataset. If the statements are correct, notify the Strobe system programmer. STR6293E nnn MESSAGES LOST [FOR JOB jobname|FOR REQUEST rrrr] Explanation: Excessive messages accumulated for either jobname or the request rrrr. Strobe is unable to write the messages to the Strobe log. System Action: Strobe discards nnn messages and continues processing. User Response: Notify the Strobe system programmer. STR6294E INVALID SYSLOG SPECIFICATION Explanation: Strobe detected an invalid Strobe log. Possible causes include assignments to: • DD Dummy • A SYSOUT class • A non-DASD device System Action: Strobe terminates. User Response: Notify the Strobe system programmer. There has probably been an installation error. STR6295E DYNAMIC ALLOCATION FAILED - RC=rc; ERC/IRC=erc/irc; dsname Explanation: Strobe cannot allocate the dataset dsname. The return code is rc, the error reason code is erc, and the information reason code is irc. System Action: processing. The requested Strobe command fails. Strobe may or may not continue User Response: Notify the Strobe system programmer. 3-126 Strobe Messages Guide STR6296I NEW SYSLOG DATA SET IDENTIFIED: SWITCHING TO dsname Explanation: Strobe determined that a new GDG log dataset dsname was cataloged and is automatically switching to the new dataset. System Action: Log processing continues using the new dataset. Strobe records all further messages in the new dataset. User Response: STR6297S None required. MODULE modname NOT FOUND IN {linklist|steplib} Explanation: System Action: Strobe cannot find the module modname in either linklist or steplib. Strobe does not process the request. User Response: Notify the Strobe system programmer. There has probably been an error installing Strobe or defining Strobe to execute from an APF-authorized library. This procedure is explained in the Strobe Installation and Customization Guide. STR6298S INCOMPATIBLE MODULE- modname - release Explanation: The module modname is invalid. release is the release of the module, and it is incompatible with the release of Strobe. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. There has probably been an installation error. STR6299I LOGSWITCH COMPLETE - NEW LOG DATA SET IS syslog name Explanation: The LOGSWITCH command completed. Strobe allocated the new GDG log dataset syslog name. System Action: Log processing continues using the new dataset. Strobe records all further messages in the new dataset. User Response: STR6300I None required. INPUT = operand Explanation: Strobe received a request for an operation and displays the operation and its operands in operand. System Action: Strobe continues processing. User Response: None required. STR6301E SYNTAX ERROR DETECTED PROCESSING - data Explanation: Strobe detected a syntax error while interpreting a request. The error was within the data shown in data. System Action: Strobe does not process the request. User Response: Correct the error and resubmit the request. STR6302E EXPECTED CONTINUATION NOT RECEIVED Explanation: System Action: You submitted an incomplete operation. Strobe does not process the request. User Response: Complete and resubmit the request. See the Strobe User Guide for a description of Strobe operations. STR6303E EXTRANEOUS OPERANDS - characters Explanation: Strobe detected non-blank characters between the operand and comment fields of a request. The character string is characters. System Action: Strobe does not process the request. User Response: Eliminate the extraneous characters and resubmit the request. Messages Produced by Strobe STR6304E REQUIRED OPERAND MISSING [- operand] Explanation: A required operand is missing. If given, the missing operand is operand. System Action: Strobe does not process the request. User Response: Specify the missing operand and resubmit the request. STR6305E 3-127 EXCESSIVE OPERAND LENGTH - operand Explanation: Strobe detected an operand (operand) whose keyword length exceeds the maximum number of characters. System Action: Strobe does not process the request. User Response: Correct the error and resubmit the request. STR6306E AUTOMATIC PROFILE CREATION SUBMISSION FAILED Explanation: The IBM MVS internal reader rejected the JCL that you submitted for automatic Profile creation. System Action: Because the internal reader rejected the JCL, a Profile could not be automatically created. User Response: You cannot create a Performance Profile automatically. You can, however, create a Performance Profile using the sample dataset, which is valid. STR6307I STROBE ADDRESS SPACE IS {SWAPPABLE | NON-SWAPPABLE} Explanation: The Strobe address space is running in either a swappable or non-swappable mode. You can set the mode using the SWAP = parameter. Setting the mode to SWAP = NO will improve the performance of the Strobe address space. System Action: None. User Response: None required. STR6308W TRANSWAP FAILED IN rc Explanation: Strobe issues this message when a customer’s request for the Strobe address space to run in SWAP = NO mode fails. The return code, rc, indicates the reason code for the failure. System Action: The Strobe address space continues to run in a swappable mode. User Response: Contact Compuware Customer Support. STR6309I DISPOSITION=KEEP IS INVALID WITH SMS PARAMETERS OVERRIDDEN TO CATLG Explanation: Strobe determined that an SMS parameter was coded on a measurement request with a dataset disposition of KEEP. System Action: Because the disposition of KEEP is invalid for an SMS dataset, Strobe uses a disposition of CATLG instead. User Response: STR6310E None required. UNIDENTIFIED OPERAND - operand Explanation: a request. Strobe encountered an unidentified operand keyword operand while processing System Action: Strobe does not process the request. User Response: Correct the error and resubmit the request. STR6311E AMBIGUOUS OPERAND - operand Explanation: Strobe encountered an ambiguous operand keyword operand while processing a request. System Action: Strobe does not process the request. User Response: Supply a unique abbreviation for the operand and resubmit the request. 3-128 Strobe Messages Guide STR6312E DUPLICATE OPERAND - operand Explanation: request. Strobe encountered a duplicate operand keyword operand while processing a System Action: Strobe does not process the request. User Response: Remove one of the operands and resubmit the request. STR6313E MUTUALLY EXCLUSIVE OPERANDS - operand1 operand2 Explanation: A request specifies keyword operands that are mutually exclusive. System Action: Strobe does not process the request. User Response: Eliminate all but one of the conflicting operands and resubmit the request. STR6314E INVALID OR MUTUALLY EXCLUSIVE OPERANDS ON ENVIRONMENT COMMAND Explanation: exclusive. System Action: An ENV command specifies keyword operands that are invalid or mutually Strobe does not process the request. User Response: Eliminate the invalid operands, or all but one of the conflicting operands, and resubmit the request. STR6315E INVALID OPERATION - operation Explanation: request. Strobe encountered an invalid operation keyword operation while processing a System Action: Strobe does not process the request. User Response: Correct the error and resubmit the request. STR6316E AMBIGUOUS OPERATION - operation Explanation: Strobe encountered an ambiguous operation keyword operation while processing a request. System Action: Strobe does not process the request. User Response: Supply a unique abbreviation for the operation, and resubmit the request. STR6317E MAXIMUM OF number LIST ENTRIES ALLOWED FOR LIST CONTAINING VALUE: value Explanation: An ADD or CHANGE request contained a list of entries that is too large. The list of entries contains the value, and is limited to number of entries. System Action: Strobe does not process the request. User Response: request again. Specify a list of values with fewer entries and submit the ADD or CHANGE STR6318W STORAGE OBTAIN FOR EPVT FAILED Explanation: An attempt to measure an OS/390 UNIX System Services fork job was made. Strobe was unable to reserve the first several pages of EPVT, which results in an abend further into the measurement process. System Action: Strobe continues processing the request. User Response: None required. STR6319E INVALID USE OF WILDCARD Explanation: An ADD or CHANGE request is invalid because it had a wildcard (*) in the first character of a jobname parameter.A wildcard character is only valid as the last character in a jobname or as the only character. System Action: Strobe does not process the request. User Response: Reenter the request using a valid character for the first character of the jobname parameter. Messages Produced by Strobe STR6320E 3-129 ddname FILE REQUIRES VSAM SHAREOPTIONS(4,3) Explanation: requires. System Action: The VSAM file ddname is not defined with SHAREOPTIONS(4,3), which Strobe Strobe fails to initialize. User Response: Use the IDCAMS option ALTER to change the VSAM file to SHAREOPTION(4,3), or delete and redefine the VSAM file with SHAREOPTIONS(4,3). STR6330E INVALID DECIMAL NUMBER - number Explanation: While processing a request, Strobe found nonnumeric characters, number, in a field that only accepts numeric numbers, or Strobe found a numeric value greater than 2,147,483,647. System Action: Strobe does not process the request. User Response: Correct the number and resubmit the request. STR6332W nnn IS TOO SMALL - min U Explanation: Strobe found a number nnn to be beneath the range of acceptable values. System Action: Strobe replaces the number with min, the smallest allowable value for that range, and continues processing. User Response: If you want to increase the value from min, use the CHANGE command to modify the request. STR6333W nnn IS TOO LARGE - max USED Explanation: Strobe encountered a number (nnn) to be above the range of acceptable values. System Action: Strobe replaces the number with max, the largest acceptable value for that range, and continues processing. User Response: If you want to decrease the value from max, use the CHANGE command to modify the request. STR6334E INVALID HEX STRING hexstring Explanation: Strobe detected an invalid operand representing a hexadecimal character string hexstring. System Action: Strobe does not process the request. User Response: Correct the value and resubmit the request. STR6335E INVALID operand SPECIFICATION Explanation: The value specified for the operand operand on the ADD, CHANGE, LIST, or SEND operation is invalid. For example, specifying EXCLUDE=*ALL will elicit this message. This message will also be issued when DISP specifies SYSTEM=*ALL. System Action: Strobe does not perform the operation. User Response: Correct the operand and resubmit the request. STR6336W STRBCXAC (parm) nnn IS TOO LARGE - max USED Explanation: Strobe user exit STRBCXAC modified a parameter, parm, and the new value, nnn, is too large. System Action: The exit interface will supply max, the largest value allowed. User Response: Notify the Strobe system programmer that the exit STRBCXAC has an error. STR6337W STRBCXAC (parm) nnn IS TOO SMALL - min USED Explanation: Strobe user exit STRBCXAC modified a parameter, parm, and the new value, nnn, is too small. System Action: The exit interface will supply min, the smallest value allowed. User Response: Notify the Strobe system programmer that the exit STRBCXAC has an error. 3-130 Strobe Messages Guide STR6338E INVALID SYSTEM NAME sysname - NOT A STROBE-XCF GROUP MEMBER Explanation: System Action: The system sysname is not a system in the Strobe-XCF group. Strobe does not process the request. User Response: Resubmit the request with a valid system name. To see a list of members in the Strobe-XCF group, enter the SHOW MEMBERS command. STR6350I nnn RECORDS COPIED FROM ACTIVE LOG Explanation: Strobe utility STRBCLOG copied nnn records from the active Strobe log to the backup dataset. System Action: processing. Strobe copied and cleared the active log. The session manager can resume User Response: None required. STR6351E DDNAME - SYSUT1 - NOT FOUND Explanation: System Action: Strobe utility STRBCLOG could not find ddname SYSUT1. Strobe terminates. User Response: Review the documentation and JCL to ensure that you adhere to the proper procedures for running Strobe. STR6360E QCREATE INTERNAL ERROR - QGWA ALREADY EXISTS Explanation: A duplicate call was made to build a queue global work area (QGWA). System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6361E fnctname INTERNAL ERROR - QGWA DOES NOT EXIST Explanation: A function fnctname failed because Strobe could not find a queue global work area (QGWA) control block. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6362I QUEUE DATASET ENVIRONMENT REMOVED Explanation: Strobe disabled the queue dataset processing. System Action: Strobe continues processing. User Response: None required. STR6363E fnctname - ddname DATASET NOT OPERATIONAL Explanation: While executing function fnctname, Strobe found that the dataset that ddname ddname refers to is not operational. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6364E fnctname - ddname ENVIRONMENT NOT ESTABLISHED Explanation: Strobe attempted to use the dataset referred to by ddname ddname without first building the necessary control blocks. The function name that detected the error is fnctname. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6365E QOPEN - ddname DATASET ALREADY OPEN Explanation: Strobe attempted to open the dataset that ddname ddname refers to and found that it was already opened. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. Messages Produced by Strobe STR6366E 3-131 fnctname - ddname - QGWA CORRUPTION DETECTED Explanation: While processing a call for function fnctname and ddname ddname, Strobe detected queue global work area (QGWA) corruption. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6367E fnctname - ddname DATASET NOT OPEN Explanation: Strobe function fnctname found that the dataset that ddname ddname refers to was already closed. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6368E fnctname - ddname PLIST MISSING OR INVALID Explanation: While processing a call for function fnctname and ddname ddname, Strobe found that the parameter list was missing or invalid. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6369E fnctname ddname - QPL POINTER INVALID AT addr Explanation: While processing function fnctname for ddname ddname, Strobe found that the queue parameter list pointer at address addr was invalid. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6370S ddname DATASET NOT ALLOCATED Explanation: During startup, Strobe determined that the dataset that ddname ddname refers to was missing. Strobe requires that this dataset be allocated. System Action: The session manager terminates. User Response: Ask the Strobe system programmer to correct the session manager JCL and restart the session manager. STR6371S QSER - ddname RESERVE ALREADY OUTSTANDING Explanation: Strobe attempted to issue two reserves for the same queue dataset that ddname ddname refers to. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6372S fnctname - ddname RESERVE NOT ISSUED Explanation: In the function fnctname, Strobe attempted to open the dataset that ddname ddname refers to without first reserving it. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6373W QOPEN - ddname VSAM OPEN STATUS RC=rc RSN=rsn Explanation: Strobe determined that the dataset that ddname ddname refers to was not properly closed and that VSAM has performed an implicit VERIFY. The VSAM return code is rc, and the VSAM reason code is rsn. System Action: Strobe continues processing normally. User Response: Notify the Strobe system programmer. STR6374E QOPEN - ddname UNABLE TO INITIALIZE DATASET RC=rc Explanation: Strobe was unable to complete the initialization of the dataset that ddname ddname refers to. The VSAM return code is rc. 3-132 Strobe Messages Guide System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6375E fnctname - failingfnct ddname STATUS RC=rc RSN=rsn Explanation: A function, failingfnct, failed for the dataset that ddname ddname refers to. The return code of the failed function is rc, and the reason code of the failed function is rsn. fnctname is the function currently executing. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6376E QDDFIND - ddname DDNAME INVALID Explanation: The ddname referred to by ddname that was passed to the Strobe QDDFIND function is invalid. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6377E QDDFIND - ddname DSNAME TABLE POINTER INVALID at addr Explanation: Strobe function QDDFIND found that the dataset table pointer in the ddname table referred to by ddname is invalid at address addr. System Action: The session manager terminates. User Response: Contact Compuware Customer Support. STR6378I call=routine LEN=length KEY=key DATE=date TIME=time Explanation: Strobe issues this message in response to a SHOW SMTRACE command or during ABEND processing. It introduces trace table record information. The type of call is call and its values may be CVENTER, CVEXIT, or ENTRY. The name of the routine is routine. The length of the data is length, and the storage key of the data is key. The date and time that Strobe wrote the trace record is date and time. STR6379I follows this message. System Action: Strobe continues processing. User Response: None required. STR6379I DATA= aaaaaaaa bbbbbbbb cccccccc dddddddd eeeeeeee ffffffff gggggggg hhhhhhhh Explanation: Following DATA=, Strobe prints the trace table record information. System Action: Strobe continues processing. User Response: None required. STR6380E PARAMETER parm INVALID WHEN STROBE IS STROBE NOT IN MULTISYSTEM MODE Explanation: The command contains a parameter parm that is invalid when Strobe is not in multisystem mode. Examples of these parameters include SYSTEM= and EXCLUDE=. System Action: Strobe does not process the command. User Response: Contact the Strobe system programmer if you would like to operate in multisystem mode. Otherwise, resubmit the command without the invalid parameter. STR6381I DATE FORMAT IS date TIME FORMAT IS time Explanation: The date format you chose is date and the time format you chose is time. If you did not change the date and time format, Strobe uses the defaults: MM/DD/YYYY (month/day/year) for the date and HH:MM:SS (hours:minutes:seconds) for the time. System Action: Strobe continues processing. User Response: None required. STR6382W INVALID TRACE TABLE. CANNOT PRINT Explanation: During ABEND recovery processing or in response to a SHOW SMTRACE command, Strobe determined that it cannot print the trace table information. System Action: Strobe continues processing. Messages Produced by Strobe 3-133 User Response: None required. To obtain trace information, ensure that the parameter TEST SMTRACE=ON is set. STR6383E CONSISTENCY ERROR PROCESSING STRBANCE PARAMETERS Explanation: During processing of the Strobe for Natural STRBANCE parameters in the Strobe PARMLIB, an error was encountered. System Action: Strobe stops processing the Strobe PARMLIB and terminates startup. User Response: Review the STRBANCE entries in the Strobe PARMLIB for errors. Required keywords are determined by ENVIRON value specified. See the Strobe Installation and Customization Guide for the STRBANCE definition. STR6390E routine INTERNAL ERROR - block INVALID AT ADDRESS addr Explanation: While performing Strobe routine routine in a multisystem environment, Strobe detected an error in the Strobe control block referenced by block. Strobe writes this message to the Strobe log. System Action: Strobe is not able to process the request. This message is followed by message STR6812I, which provides additional diagnostic information. User Response: Contact Compuware Customer Support. STR6391I {SESSION REQUESTER | SESSION MANAGER} REGION SIZE {ABOVE | BELOW} 16MB IS nnnn BYTES (nnnnKB) Explanation: The region size of a component of Strobe, the session requester or session manager, above or below 16MB is nnnn bytes (hexadecimal), nnnnKB (decimal). Strobe issues this message in response to a STATUS command. System Action: None. User Response: None required. STR6400W XCFGROUP PARAMETER IGNORED - SYSTEM sysname IS IN XCF-LOCAL MODE Explanation: Strobe does not process the XCFGROUP parameter because the system sysname is in XCF-LOCAL mode. The system sysname is not configured to run in a sysplex environment. System Action: Strobe continues processing. User Response: None required. To prevent Strobe from issuing this message, remove the XCFGROUP parameter from the PARMLIB dataset. STR6401I STROBE-XCF GROUP NAME IS: xcfgroup Explanation: The name of the Strobe-XCF group is xcfgroup. System Action: None. User Response: None required. STR6402I STROBE-XCF GROUP MEMBERS ARE: localsysname sysname1 sysname2...sysnamenn Explanation: This message lists the names of the active systems in the Strobe-XCF group beginning with local system localsysname and continuing to the last system sysnamenn. System Action: None. User Response: None required. STR6403I SYSTEM sysname IS NOT A MEMBER OF A STROBE-XCF GROUP Explanation: group. The system named sysname is not defined as a member of any Strobe-XCF System Action: None. User Response: None required. STR6404I SYSTEM sysname DOES NOT SUPPORT THE USE OF XCF GROUPS Explanation: The system sysname does not support the use of XCF Groups. To use XCF Groups, the system must be at MVS/ESA V4R1 or higher. System Action: Strobe does not process the request. 3-134 Strobe Messages Guide User Response: STR6405E None required. routine XCF MEMBER xcfname NOT FOUND IN MEMBER LIST Explanation: While performing Strobe routine routine in a multisystem environment, Strobe uses IBM’s cross-system coupling services to communicate with other Strobe systems in the sysplex. Strobe issues this message when a member of the Strobe-XCF group attempted to communicate with another member of the group, named xcfname. At this time, xcfname is not an active member of the Strobe-XCF group, so it is not able to receive or send messages. System Action: Strobe does not process the request. User Response: None required. If the request fails and the problem persists, contact the Strobe system programmer who can verify that system xcfname is active. If this system is active, the system programmer may want to stop and restart the version of Strobe on system xcfname. STR6406W XCF FUNCTION IXCfnctname FAILED, RC=rc, RSN=rsncode Explanation: One of the services provided by the cross-system coupling facility (XCF) failed. The service name is identified as IXCfnctname. Possible service names, and their associated function, are as follows: – – – – – IXCJOIN - join an XCF group IXCLEAVE - leave an XCF group IXCMSGI - receive a message from another member of the XCF group IXCMSGO - send a message to another member of the XCF group IXCQUERY - determine status and active members of the XCF group The return codes and reason codes issued from the failing XCF service are identified by rc and rsncode. For the explanations of these return and reason codes, see the IBM z/OS MVS Programming Authorized Assembler Services Reference volumes. System Action: Strobe may not be able to join or leave the Strobe-XCF group, or to communicate with other members of the Strobe-XCF group. User Response: STR6407E Notify the Strobe system programmer. routine XCF MEMBER xcfname NOT FOUND IN MEMBER LIST FOR REQUEST nnnn Explanation: While performing Strobe routine routine in a multisystem environment, Strobe uses IBM’s cross-system coupling services to communicate with other Strobe systems in the sysplex. Strobe issues this message when a member of the Strobe-XCF group attempted to communicate with another member of the group, named xcfname. At this time, xcfname is not an active member of the Strobe-XCF group, so it is not able to receive or send messages. The failed communication attempt occurred while processing request number nnnn. System Action: Strobe does not process the request. User Response: None required. If the request fails and the problem persists, contact the Strobe system programmer who can verify that system xcfname is active. If this system is active, the system programmer may want to stop and restart the version of Strobe on system xcfname. STR6408S CONTINUE STROBE VERSION release ENVIRONMENT EXISTS. STROBE INITIALIZATION CANNOT Explanation: Strobe found an existing older Strobe environment, release, but the Strobe system programmer did not specify REMV_OLD=YES in the parameter dataset. System Action: Strobe initialization terminates. User Response: Bring up a Strobe Version release environment and issue the SEND, QUIT command against all active requests. If Strobe release is not available, stop the jobs that are being measured. When there are no more active requests, the system programmer must specify REMV_OLD=YES in the parameter dataset member ALLOCATE and begin initializing Strobe. STR6409I BEGINNING OF MESSAGES FROM PREVIOUS STROBE ENVIRONMENT Explanation: Upon initializing, Strobe found a pre-existing Strobe environment and is reporting the messages for that environment. The Strobe messages follow. System Action: Strobe continues processing. User Response: None required. Messages Produced by Strobe STR6410I 3-135 END OF MESSAGES FROM PREVIOUS STROBE ENVIRONMENT Explanation: Upon initializing, Strobe found a pre-existing Strobe environment and is reporting the messages for that environment. This is the end of the Strobe messages. System Action: Strobe continues processing. User Response: None required STR6411W {CANNOT STOP | TERMINATING} STROBE. THE FOLLOWING REQUESTS {ARE | WILL REMAIN} ACTIVE sre nnn [, sre nnn, sre nnn.] Explanation: You issued a STOP or TERMINATE command, but one or more Strobe requests are still active. Strobe reports active request(s) in Strobe request element sre nnn, and if present, Strobe reports additional requests in sre nnn. System Action: In response to a STOP command, Strobe continues processing. In response to a TERMINATE command, Strobe stops processing and the requests remain active. User Response: If you issued a STOP command, wait for the measurement requests to be completed or, if necessary, stop the active measurements and reissue the STOP command. If you cannot stop the active measurements, issue the TERMINATE command. If you issued the TERMINATE command, no response is required. STR6412I STROBE FOUND A PREVIOUSLY EXISTING STROBE ENVIRONMENT Explanation: Upon initialization, Strobe identified a pre-existing Strobe environment. System Action: Strobe continues processing. User Response: None required. STR6414I ISSUING {SUSPEND | RESTART} FOR REQUEST # nnnn Explanation: Upon initialization, Strobe found request nnnn to still be active. System Action: Strobe continues initializing. The active request nnnn is suspended during Strobe initialization and is restarted once Strobe initialization is complete. User Response: STR6415W None required. SERIALIZATION UNAVAILABLE FOR {SRE | CVU | SMI | SMT | SMW | SMW2} CHAIN Explanation: While attempting to verify its control block chains during recovery processing, Strobe was unable to acquire serialization for one of the following chains: SRE (Strobe request element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), SMW2 (session manager work element for a specific user). System Action: Strobe continues processing. User Response: None required. STR6416W INVALID CHAINING IDENTIFIED IN {SRE | CVU | SMI | SMT | SMW | SMW2} CHAIN Explanation: While attempting to verify its control block chains during recovery processing, Strobe found one of the following chains to be invalid: SRE (Strobe request element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), SMW2 (session manager work element for a specific user). System Action: Strobe processing continues. User Response: None required. STR6417W INVALID DATA FOUND IN {SRE | CVU | SMI | SMT | SMW | SMW2} ELEMENT Explanation: While attempting to verify its control block chains during recovery processing, Strobe found that an item in one of the following chains was not an element: SRE (Strobe request element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), SMW2 (session manager work element for a specific user). System Action: Strobe continues processing. User Response: None required. 3-136 Strobe Messages Guide STR6418I ELEMENT PRIOR TO ERROR IS AS FOLLOWS {SRE | CVU | SMI | SMT | SMW | SMW2} Explanation: While attempting to verify its control block chains during recovery processing, Strobe detected a problem in one of its chains. Strobe displays the chain element prior to the problem element. The element could be: SRE (Strobe request element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), or SMW2 (session manager work element for a specific user). System Action: Strobe continues processing. User Response: None required. STR6419I ELEMENT CONTAINING ERROR IS AS FOLLOWS {SRE | CVU | SMI | SMT | SMW | SMW2} Explanation: While attempting to verify its control block chains during recovery processing, Strobe detected a problem in one of its chains. Strobe displays the problem element. The element could be: SRE (Strobe request element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), or SMW2 (session manager work element for a specific user). System Action: Strobe continues processing. User Response: None required. STR6420W STORAGE AVAILABLE BUT NOT ALLOCATED BY APPLICATION Explanation: While attempting to verify its control block chains during recovery processing, Strobe found storage on a chain that is not allocated to this version of Strobe. This message is always preceded by STR6416W, which identifies the chain in which the problem occurred. System Action: Strobe continues processing. User Response: None required. STR6421W INVALID POINTER FOUND IN FOLLOWING STRUCTURE. NEXT ELEMENT POINTED TO IN CHAIN DOES NOT EXIST {SRE | CVU | SMI | SMT | SMW | SMW2} Explanation: While attempting to verify its control block chains during recovery processing, Strobe found a control block on one of the following chains that contained an invalid forward pointer: SRE (Strobe Request Element), CVU (session manager user element), SMI (session manager internal element), SMT (session manager timer queue), SMW (session manager work element), or SMW2 (session manager work element for a specific user). System Action: Strobe continues processing. User Response: None required. STR6423W CANNOT SUSPEND REQUEST # nnnn, STROBE INITIALIZATION CONTINUING Explanation: Either Strobe experienced an ABEND or you ended the Strobe session with a TERMINATE command. Upon initialization, Strobe found request nnnn to be active and Strobe was unable to suspend it. System Action: Strobe continues initialization and moves the active request to the version of Strobe that is initializing. User Response: STR6424W None required. The active measurement request may ABEND. LICENSE VERIFICATION WARNING, RETURN CODE rc REASON CODE erc Explanation: The Strobe base license is invalid for the reason specified by return code rc and error reason code erc. Strobe writes the explanation of the warning to the Strobe Log. If License Management message suppression and distribution is active, this message will not appear. However, the warning details are routed according to your LMSINIT SYSIN parameters. Note: You may have entered the warning period for your current license. Ignore this message if you have already requested a new license. System Action: Strobe continues processing. User Response: assistance. Contact Compuware License Management System Customer Support for Messages Produced by Strobe 3-137 STR6425S STROBE VERSION release ENVIRONMENT HAS ACTIVE MEASUREMENTS AND CANNOT BE DELETED Explanation: Strobe found that an existing Strobe environment, Version release, has active requests and REMV_OLD=YES is specified. A new version of Strobe cannot be installed with the same version letter as an older version that has active measurements. System Action: Strobe initialization terminates. User Response: Bring up a Strobe Version release environment and issue the SEND,QUIT command against all active requests. If Strobe Version release is not available, stop the active measurement requests. If you cannot stop these measurement requests, initialize the new version of Strobe with a different version letter and a different SVC. STR6426E SIGN FOR THE TERMDATE PARAMETER IS INCORRECT Explanation: The sign for the TERMDATE parameter is either incorrect or omitted. The TERMDATE parameter sign must be an F. System Action: Strobe session manager does not initialize. User Response: Ensure that the TERMDATE parameter sign is an F. If the problem persists, contact Compuware Customer Support. STR6427W BLKSIZE WAS NOT SPECIFIED IN THE STROBE PARAMETER DATASET Explanation: System Action: initialization. A value for BLKSIZE was not entered in the Strobe parameter dataset. Session Manager sets the BLKSIZE parameter to 8192 and continues User Response: Update the Strobe parameter dataset to specify a value for BLKSIZE between 8192 and 32760. STR6428E STROBE FOR UNIX SYSTEM SERVICES IS NOT SUPPORTED ON SYSTEM sysname Explanation: Strobe cannot process a request to display OS/390 UNIX System Services processes because Strobe for UNIX System Services is not installed on system sysname. System Action: Strobe does not complete your request. User Response: programmer. To install Strobe for UNIX System Services, notify the Strobe system STR6429W UNIX SYSTEM SERVICE uss_routine RETURNED RC=rc RSNC=rsnc Explanation: The OS/390 UNIX System Services routine uss_routine returned an error while processing a request. The UNIX System Services return code is rc; the UNIX System Service reason code is rsnc. System Action: Strobe terminates the request. User Response: Refer to the IBM OS/390 UNIX System Services Messages and Codes manual to interpret the return codes rc and reason codes rsnc. STR6430W OPERATING SYSTEM LEVEL ON SYSTEM IS level NEEDS MINIMUM V02R06M00 Explanation: The display process function requires functionality level introduced in OS/390 Version 2 Release 6. System Action: Strobe terminates the request. User Response: To upgrade your operating system to OS/390 Version 2 Release 6, notify your Strobe system programmer. STR6431W THE SESSION MANAGER USER ID IS NOT DEFINED TO THE SECURITY PRODUCT Explanation: The Strobe session manager user identification does not have access to the systems security product. System Action: functions. Strobe terminates the request to access OS/390 UNIX System Services User Response: Notify the Strobe system programmer. 3-138 Strobe Messages Guide STR6432W SESSION MANAGER DOES NOT HAVE ACCESS TO SUPERUSER AUTHORITY Explanation: authority. The Strobe session manager user identification does not have SUPERUSER System Action: Strobe terminates the request to access OS/390 UNIX System Services process data. User Response: STR6433E Notify the Strobe system programmer. MEASUREMENT OF BPXBATCH RESTRICTED. CONTACT COMPUWARE Explanation: Strobe cannot measure the BPXBATCH utility because you did not apply a program temporary fix (PTF) for IBM APAR OW38618 to your operating system. System Action: Strobe does not complete your measurement request. Your request remains in active initializing status. User Response: Delete your measurement request. Contact IBM or Compuware Customer Support to obtain the PTF for IBM APAR OW38618 that is compatible with your operating system. STR6434E QUEUED MEASUREMENT OF SPAWNED OR FORKED ADDRESS SPACE HAS FAILED Explanation: Strobe implant processing failed because of the problem with the environment. System Action: The job continues to run. The request is marked complete, but measurement has failed. User Response: STR6435I Resubmit the measurement request. USING LOCAL SYSTEM LICENSE DATA Explanation: Strobe license management data is refreshed with the local system license data. System Action: Strobe continues processing. User Response: None required. STR6436E LICENSE VERIFICATION FAILED RETURN CODE rc REASON CODE erc Explanation: The Strobe base license is invalid for the reason specified by return code rc and error reason code erc. Strobe writes the explanation of the failure to the Strobe Log. System Action: All options are marked unlicensed and Strobe does not initiate new measurements. At initialization, Strobe stops processing. User Response: assistance. STR6436W Contact Compuware License Management System Customer Support for LICENSE VERIFICATION FAILED RETURN CODE rc REASON CODE erc Explanation: The Strobe base license is invalid for the reason specified by return code rc and error reason code erc. Note: You may have entered the warning period for your current license. Ignore this message if you have already requested a new license. System Action: All options are marked unlicensed and Strobe does not initiate new measurements. At initialization, Strobe stops processing. User Response: Contact the License Management System customer support group if the rc and erc are one of the following: • If rc = 4 and erc = 566, 571, 577, 582, 590, 591, 592, or 593 • If rc =8 and erc = 562, 563, 564, 567, 568, 569, 573, 574, 575, or 578 Otherwise, contact Compuware Customer Support for an explanation of the return codes and error reason codes. STR6437I LMRREFRESH {COMPLETED | IN PROGRESS | FAILED} ON SYSTEM sysname Explanation: This message appears in response to a LMREFRESH command you issued or an internal LMREFRESH. The message indicates one of the following statuses: • COMPLETED the refresh completed successfully on the system sysname. Messages Produced by Strobe 3-139 • IN PROGRESS at present a refresh is already being driven on system sysname. • FAILED an invalid Strobe license was found on system sysname or, in a sysplex, Strobe was unable to send a license data request to system sysname. System Action: In a sysplex, Strobe will use the license data from all systems that responded. User Response: If the Strobe base license is invalid, contact Compuware Customer Support. In a sysplex, this message may indicate sysplex or storage availability problems. STR6438I LICENSE DATA UNAVAILABLE FROM SYSTEM sysname Explanation: Strobe is unable to obtain license data from system sysname in a sysplex environment. System Action: Strobe continues processing license data for those systems from which it can obtain it. User Response: None required. This message, however, may indicate problems with the sysplex environment that warrant further investigation. STR6439I GLOBAL LICENSE DATA {REFRESHED | NOT REFRESHED} ON SYSTEM sysname Explanation: Strobe either has or has not obtained license data from system sysname. System Action: Strobe processes license data for those systems from which it is available. User Response: None required. STR6440E UNABLE TO OBTAIN STORAGE FOR purpose Explanation: System Action: Strobe is unable to obtain storage for the purpose identified in purpose. Strobe terminates if the purpose is LICENSE MANAGEMENT CALL. User Response: Configure your Strobe environment so that Strobe can obtain 6144 bytes of subpool 1 storage. STR6441E INVALID LICENSE CONFIGURATION: text Explanation: Strobe license management has detected the invalid license combination described in text. System Action: All options are marked unlicensed and Strobe cannot initiate new measurements. At initialization, Strobe stops processing. User Response: STR6442E Contact Compuware Customer Support. ALLOCATION FOR LICENSE MANAGEMENT SUBSYSTEM ddname FAILED Explanation: failed. The dynamic allocation of ddname provided in the parameter library LMSS System Action: Strobe will continue processing using the default license subsystem. User Response: Correct the dynamic allocation failure and restart Strobe. STR6443E INVALID LMSS VALUE SPECIFIED Explanation: The value specified in the Strobe parameter library member for the LMSS parameter is invalid. The value can be either blank or specified as follows: CWSB in the first four characters and the name of the license management subsystem in the second four characters. When the value is blank, Strobe uses the primary default license management subsystem. System Action: Strobe initialization fails. User Response: member. Correct the value specified for LMSS in your Strobe parameter library STR6444W OPTION CICS OPTION {CAPTBUFF| DSSIZE} IGNORED; INVALID WITHOUT RLI AND/OR TRAN Explanation: If you specify a CICS option of either CAPTBUFF or DSSIZE, you must also specify RLI, TRAN, or both RLI and TRAN. System Action: Strobe continues processing without the option CAPTBUFF or DSSIZE. 3-140 Strobe Messages Guide User Response: None required. STR6445I ISSUE THE TERMINATE COMMAND TO STOP STROBE AND END ACTIVE REQUESTS AND USERS Explanation: Strobe cannot execute the STOP command that you issued because users or requests are active on the system. System Action: Strobe continues to process, and does not execute the STOP command. User Response: To use the STOP command, you must first end active measurements and users. If you need to stop Strobe immediately or cannot end active measurements, you can issue the Terminate command. STR6447E MEASUREMENT SERVICES WAS NOT STOPPED BY AN OPERATOR AND CANNOT BE STARTED BY AN OPERATOR Explanation: An operator START command was issued for STRBMSAS, but the Measurement Services Address Space (MSAS) was not stopped via an operator STOP command. Measurement Services has failed or been stopped internally. System Action: Strobe continues processing. Measurement Services are not restarted. User Response: None STR6448E {MEASUREMENT SERVICES INITIALIZATION FAILED| MEASUREMENT SERVICES RESTARTS REPEATEDLY FAILING} RETURN CODE= REASON CODE= -orExplanation: If the message reads Measurement Services initialization failed, Strobe is unable to start Measurement Services during Strobe initialization. The reason and return code come from the ASCRE macro. If the messages Measurement Services Restarts Repeatedly failing, Strobe has attempted to restart the Measurement Services Address Space (MSAS) 3 times in the last 15 minutes. System Action: Strobe initialization failed. Once Strobe is initialized, Strobe does not attempt to restart Measurement Services User Response: During Strobe initialization, fix the problem and restart Strobe. After Strobe is initialized, no response is required. To restart Measurement Services in this situation, stop and restart Strobe. STR6449E NAME/TOKEN {CREATE|DELETE} FOR SESSION MANAGER PAIR FAILED, RETURN CODE= Explanation: failed. The NAME/TOKEN CREATE or DELETE for the Strobe NAME/TOKEN pair System Action: Processing continues. User Response: None required. STR6452W {AUTOCANDIDATE | FAULT MANAGER | AUTOMEASURE} IS INVALID WITHOUT {AUTOMONITOR | AUTOSTROBE}. {SETTING FAULT_MANAGER=NO|SETTING AUTOMEASURE=NO} This message appears in the following forms: AUTOCANDIDATE IS INVALID WITHOUT AUTOMONITOR. SETTING AUTOCANDIDATE=NO Explanation: Strobe installation parameters specified that AutoStrobe should not be active (AUTOSTROBE=NO). AutoStrobe monitoring must be active on the system, where this instance of Strobe is being initialized. System Action: Strobe continues to initialize, but there will be no AutoStrobe monitoring. FAULT MANAGER IS INVALID WITHOUT AUTOSTROBE. SETTING FAULT_MANAGER=NO Explanation: Strobe was installed with FAULT_MANAGER=YES in the Strobe parameter dataset, requesting that Abend-AID Fault Manager be notified, but AutoStrobe is not licensed. System Action: Strobe continues to initialize, but will not send notification to the AbendAID Fault Manager. Messages Produced by Strobe 3-141 AUTOMEASURE IS INVALID WITHOUT AUTOSTROBE - SETTING AUTOMEASURE=NO Explanation: AUTOMEASURE=YES is specified in the installation parameter dataset, but AutoStrobe is not licensed. System Action: initialize. The AUTOMEASURE parameter is set to NO, and Strobe continues to User Response: Notify the Strobe system programmer. STR6453E AUTOMONITOR IS INVALID WITHOUT AUTOSTROBE. SETTING AUTOMONITOR=NO Explanation: AUTOSTROBE=YES was specified in the ALLOCATE member, but Strobe is not licensed for AutoStrobe. System Action: AutoStrobe is disabled. User Response: To use AutoStrobe, contact Compuware to obtain a license for it. STR6454E AUTOMONITOR IS INVALID WITHOUT STRAUTO Explanation: AUTOSTROBE=YES was specified in the ALLOCATE member, but the STRAUTO parameter for the AutoStrobe dataset name is not specified. System Action: Session Manager initialization fails. User Response: Specify a value for STRAUTO in the ALLOCATE member. STR6455E nnnn NEW AUTOMONITOR REQUEST NOT ADDED, {REDUNDANT|DUPLICATE} OF REQUEST Explanation: An ADD request was issued for an AutoStrobe monitor request. A match is found if both requests are AutoStrobe monitor requests with the same job name, program name step and proc names, and system. If the message reads REDUNDANT, SYSTEM=*ALL was specified on either the existing request and the ADD. If the message reads DUPLICATE, the same system was specified for the SYSTEM parameter on both the existing request and the ADD. System Action: The ADD request is ignored. User Response: If the existing AutoStrobe monitoring request is adequate, none required. If not, delete the existing request and then ADD the new request. STR6456E AUTOMONITOR IS NOT ACTIVE Explanation: An AutoStrobe function ADD, DELETE, CHANGE or copy of an AutoStrobe request was issued, but AutoStrobe is not active. System Action: Strobe attempts to process the request, updates it and saves the information to update AutoStrobe when it reactivates. User Response: None required, although you can check why AutoStrobe is inactive. STR6457W AUTOMONITOR PARAMETERS REQUIRE AUTOSTROBE - IGNORING AUTOMONITOR PARAMETERS Explanation: A Strobe user issued an ADD request that contains AutoStrobe parameters, but AutoStrobe is either not authorized or was not specified on the request System Action: AutoStrobe parameters on the request are ignored. User Response: If you want to make the ADD request an AutoStrobe monitored request, delete the original request and re-issue the ADD request with the correct AutoStrobe requirements. STR6458E FAILURE TRIGGERING MEASUREMENT FOR AUTOMEASURE | AUTOMONITOR TEMPLATE nnnn - TEMPLATE NOT FOUND This message appears in the following forms: FAILURE TRIGGERING MEASUREMENT FROM AUTOMEASURE TEMPLATE  - TEMPLATE NOT FOUND Explanation: An AutoMeasure measurement was requested, but Strobe could not find the AutoMeasure template to clone the request. 3-142 Strobe Messages Guide System Action: The AutoMeasure measurement request is not added; however, Strobe processing continues. User Response: Contact Compuware Customer Support. FAILURE TRIGGERING MEASUREMENT FROM AUTOMONITOR TEMPLATE  - TEMPLATE NOT FOUND Explanation: AutoStrobe requested that a measurement be initiated for AutoStrobe monitored request nnnn, but the monitored request no longer exists. System Action: The AutoStrobe monitored request is not added. User Response: None required. STR6460E COMMAND REJECTED - STROBE INTERFACE REQUIRED FOR AUTOMONITOR {ADD|CHANGE|DELETE} Explanation: An ADD, CHANGE or DELETE command was issued for an AutoStrobe request from other than the Strobe/ISPF interface. System Action: The command is ignored. User Response: Use the Strobe/ISPF interface to issue AutoStrobe commands. STR6461S AutoMonitor PC ABEND recovery complete - {terminating | continuing} yyyy/zzzz Explanation: Strobe experienced an ABEND. yyyy is the amount of stack space used. zzzz is the amount of stack space allocated. System Action: Strobe continues or terminates, as stated in the message. User Response: Contact the Strobe system programmer to correct the problem. STR6462E STROBE SQL AGENT WAS NOT STOPPED BY AN OPERATOR AND CANNOT BE STARTED BY AN OPERATOR Explanation: The operator has issued a START command for the Strobe SQL Agent. However, the Strobe SQL Agent was not stopped by an operator, and therefore an operator START command is not permitted. System Action: Strobe does not process the request. User Response: None required. Under this circumstance, to restart the Strobe SQL Agent, you must stop and restart the Strobe session manager. STR6463I STROBE SQL AGENT text The Strobe SQL agent could not be initialized because of text: • INITIALIZATION FAILED RETURN CODE=xx, REASON CODE=yy Explanation: The Strobe SQL Agent failed to initialize. The return code xx and reason code yy are those from the MVS ASCRE macro. System Action: Strobe initialization continues without the Strobe SQL Agent. User Response: Contact Customer Support to determine why the Strobe SQL Agent initialization is failing. • STARTUP PROCEDURE FAILURE Explanation: System Action: The Strobe SQL Agent startup procedure is failing. Strobe initialization continues initialization without the Strobe SQL Agent. User Response: Determine why the Strobe SQL Agent startup procedure is failing. Under this circumstance, to restart the Strobe SQL Agent, you must stop and restart the Strobe session manager. • RESTARTS REPEATEDLY FAILING Explanation: System Action: The Strobe SQL Agent has failed three times within a 15-minute period. Strobe stops trying to restart the Strobe SQL Agent. Messages Produced by Strobe 3-143 User Response: Determine why the Strobe SQL Agent startup procedure is failing. The only way to restart the Strobe SQL Agent in this situation is to stop and restart the Strobe Session Manager. STR6464I EXISTING STROBE SQL AGENT BEING USED Explanation: Strobe initialization found an existing Strobe SQL Agent. System Action: Strobe uses the exiting Strobe SQL Agent and does not start another. User Response: None required. STR6465I STROBE SQL AGENT INITIALIZATION COMPLETE Explanation: The Strobe SQL Agent initialized successfully. System Action: Strobe SQL Agent processing begins. User Response: None required. STR6466I STROBE SQL AGENT IS INVALID WITHOUT DB2 Explanation: The Strobe parameter library specifies SSA=YES. However, this system does not have a valid Strobe for DB2 license. System Action: Strobe SQL Agent is set to NO. User Response: None required. To use the Strobe SQL Agent, Strobe for DB2 must be licensed and installed. STR6471E REQUEST IS NOT THE AUTOMEASURE TEMPLATE. INVALID DELETE COMMAND Explanation: A DELETE command with TYPE=AUTOMEAS|AUTOMEASURE was issued for a request that is not the AutoMeasure template. System Action: The AutoMeasure template is not deleted. User Response: Enter the request number for the AutoMeasure template. STR6472I AUTOMEASURE TEMPLATE CREATED - REQUEST Explanation: Upon initialization, Strobe checks if the AutoMeasure template exists. If one does not exist, Strobe creates the AutoMeasure template. Strobe will do so only if AutoStrobe is licensed and the AUTOMONITOR and AUTOMEASURE installation parameters are set to YES in the parameter dataset. System Action: Strobe creates an AutoMeasure template. User Response: None required. STR6479W CVU IS NOT A SESSION REQUESTER CVU Explanation: During shutdown, Strobe found a CVU pointing to an address space that was no longer a Session Requester address space. System Action: Strobe deletes the CVU. User Response: None required. STR6480I ATTACH FILTER IDENTIFIED PROGRAM xxxxxxxx BEING ATTACHED; xxxxxxxx IS ON THE EXCLUDEAQ LIST Explanation: Strobe detected program xxxxxxxx beginning to execute. This program is on the list specified to the EXCLUDEAQ installation parameter in the parameter dataset. EXCLUDEAQ specifies programs for which an Add Queued measurement request will not be permitted. System Action: If there is an Add Queued request for this program, Strobe will not initiate a measurement for it. User Response: To measure the program, do one of the following: • Issue an Add Active request for the program while it is executing. • Remove the program from the list specified to the EXCLUDEAQ parameter. 3-144 Strobe Messages Guide STR6482 ADD QUEUED UNABLE TO OBTAIN ASID ENQUEUE FOR ASID=xxxx Explanation: During initialization of an Add Queued request, Strobe could not obtain the enqueue on the ASID. System Action: The measurement request fails. User Response: Delete any active AutoStrobe requests for the specified job/stepname and resubmit the measurement request. STR6483E @@PCMSAS CALL RECEIVED RC xxxx Explanation: code. A call to the @@PCMSAS service failed for the reason specified in the return System Action: the request. The @@PCMSAS function is not executed and AutoStrobe does not process User Response: Contact Compuware Customer Support. STR6484W {AUTOTRAN|CANDIDATE CREATE} MONITORING REQUEST nnnn BEING SUSPENDED TO ALLOW ADD ACTIVE MEASUREMENT Explanation: A measurement is starting in an address space in which there is an active AutoStrobe transaction monitoring or an AutoStrobe create candidates request. System Action: proceed. Strobe stops the active AutoStrobe request and allows the measurement to User Response: None required. Licensing Messages STR6510I AutoStrobe is (not) licensed (and disabled) Explanation: The Autostrobe feature is (not) licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6511I Interface is licensed (and disabled) Explanation: The Strobe interface feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6512I Unix_s/svr is licensed (and disabled) Explanation: The Strobe UNIX feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6513I CICS is licensed (and disabled) Explanation: The Strobe CICS feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6514I DB2 is licensed (and disabled) Explanation: The Strobe DB2 feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. Messages Produced by Strobe User Response: STR6515I 3-145 None required. DB2_DDF is licensed (and disabled) Explanation: The Strobe DB2_DDF feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6516I IMS is licensed (and disabled) Explanation: The Strobe IMS feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6517I IDMS is licensed (and disabled) Explanation: The Strobe IDMS feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6518I ADABAS is licensed (and disabled) Explanation: The Strobe ADABAS feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6519I FORTRAN is licensed (and disabled) Explanation: The Strobe Fortran feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6520I CA_OPTIMIZ is licensed (and disabled) Explanation: The Strobe CA_OPTIMIZ feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6521I CA_PANEXEC is licensed (and disabled) Explanation: The Strobe CA_PANEXEC feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6522I MQ_SERIES is licensed (and disabled) Explanation: The Strobe MQ_SERIES feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6523I JAVA is licensed (and disabled) Explanation: The Strobe JAVA feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". 3-146 Strobe Messages Guide System Action: None. User Response: None required. STR6524I PL/I is licensed (and disabled) Explanation: The Strobe PL/I feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6525I COBOL is licensed (and disabled) Explanation: The Strobe COBOL feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6526I C_SUPPORT is licensed (and disabled) Explanation: The Strobe C_SUPPORT feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6527I ADVNTG_GEN is licensed (and disabled) Explanation: The Strobe ADVTG_GEN feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6528I ISTROBE is licensed (and disabled) Explanation: The Strobe iStrobe feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. STR6529I WEBSPHERE is licensed (and disabled) Explanation: The Strobe WebSphere feature is licensed at this site. If it has been disabled, in PARMLIB it will be noted as "and disabled". System Action: None. User Response: None required. Additional Strobe Messages STR6800I DSN=dataset name Explanation: This message identifies the dataset related to the preceding message. If it is a sample dataset, dataset name is in the format prefix.jobname.ssssdddd [.suffix]. System Action: See the preceding message. User Response: See the preceding message. STR6801I STROBE SAMPLE DATA SET ALLOCATED VOLSER=volser [EXISTING DATA SET USED] Explanation: Strobe allocated a sample dataset on the volume identified by volser. EXISTING DATA SET USED appears in this message if an existing dataset is reused. The fully qualified name of the dataset is given in message STR6800I. System Action: Strobe continues processing. Messages Produced by Strobe User Response: STR6802I 3-147 None required. STROBE SAMPLE DATA SET DEALLOCATED Explanation: Strobe allocated and cataloged a sample dataset. It can be used to produce a Strobe Performance Profile. The fully qualified name of the dataset is given in message STR6800I. System Action: Strobe completes measurement of the sample dataset. User Response: None required. STR6803S STROBE SAMPLE DATA SET ALLOCATION FAILED - RC=rc; ERC/IRC/RSN=erc/irc/rsn Explanation: Strobe was unable to allocate a sample dataset. The fully qualified name of the sample dataset is given in message STR6800I. The error reason code is erc, the information reason code is irc, and the SMS reason code is rsn. For an explanation of the codes, see the IBM z/OS MVS Programming Authorized Assembler Services Guide for interpreting DYNALLOC return codes. Note that rsn is applicable only when erc=97xx and otherwise will display as 00000000. System Action: Strobe terminates sampling. User Response: Submit a new request to initialize a new measurement session. Ensure that the sample dataset name meets all access facility requirements and that a dataset of the chosen name can be written in the address space of the target program. STR6804E STROBE SAMPLE DATA SET DEALLOCATION FAILED - RC=rc; ERC/IRC=erc/irc Explanation: Strobe was unable to deallocate a sample dataset. The fully qualified name of the dataset is given in message STR6800I. The error reason code is erc and the information reason code is irc. The sample dataset may not be available for producing a Strobe Performance Profile until the target program has completed execution. System Action: The Strobe measurement session continues. User Response: Wait for the target program to complete execution. If you cannot produce a Performance Profile, contact your Strobe system programmer. STR6805E STROBE SAMPLE DATA SET ALLOCATION FAILED - HSM NOT ACTIVE RC=100 Explanation: Strobe could not allocate a dataset because DFHSM was not active. System Action: Strobe terminates sampling. User Response: Resubmit the measurement request after DFHSM becomes active. STR6806E AN ERROR OCCURRED RETURNING ACTIVE MEASUREMENT SESSION DATA REQUESTED FROM SYSTEM sysname Explanation: Strobe encountered an error while attempting to return the data you requested from the system sysname. System Action: Strobe is unable to return the data that you requested. User Response: programmer. Resubmit the request. If the problem continues, notify the Strobe system STR6807E AN ERROR OCCURRED FORMATTING ACTIVE MEASUREMENT SESSION DATA RETURNED FROM THE SYSTEM sysname Explanation: Strobe encountered an error while attempting to format the data that you requested from system sysname. System Action: Strobe is unable to present the data that you requested. User Response: programmer. Resubmit the request. If the problem continues, notify the Strobe system STR6808E TIME OUT CONDITION OCCURRED WHILE PERFORMING requesttype OPERATION FOR REQUEST nnnn Explanation: Because of processing delays related to the target system, the sysplex, or the session manager, request nnnn may not have completed within the required time interval. The type of request (for example Add Active, Add Queued, Status) is indicated by the variable 3-148 Strobe Messages Guide requesttype. If the request type does not operate on a specific request number, then N/A (not applicable) will appear instead of a number. System Action: processing. Strobe is unable to determine the state of request nnnn but continues User Response: For more information regarding this request, refer to the Strobe log and search on the request number nnnn. If the time out condition is related to processing delays, Strobe follows this message with messages STR6811I and STR6812I. Otherwise, examine the log for additional messages that indicate the state of the session manager. STR6809S STROBE SYSQUEUE DATA SET IS FULL: NEW REQUESTS NOT ALLOWED - THE CONTINUED OPERATION OF STROBE WILL BE SEVERELY IMPAIRED Explanation: All of the allocated extensions for the queue dataset are used. You cannot make any new measurement requests; the overall operation of Strobe is severely limited. You may, however, display and delete requests. System Action: Strobe does not process any new measurement requests. User Response: Notify the Strobe system programmer. As a possible temporary solution, the system programmer can display and then delete any unwanted requests from the dataset. In some cases, deleting unwanted requests will rectify the situation. To continue processing new requests, contact the Strobe system programmer. The system programmer needs to clean up and reorganize the file. If a Strobe-XCF group exists, the system programmer must shut down all members of the Strobe-XCF group before attempting to clean up and reorganize the file. For specific instructions, see the Strobe Installation and Customization Guide. STR6810W ddname DATA SET IS FULL Explanation: All of the allocated extensions for the Strobe dataset, file ddname, are used. The value for ddname can be SYSMSG or SYSGROUP. File SYSMSG is the Strobe message dataset, which contains messages issued by Strobe and module tracking information. File SYSGROUP is the Strobe request group dataset, which is present when AutoStrobe is installed to contain request groups and their associated request group elements. System Action: Strobe functions requiring SYSMSG or SYSGROUP are unavailable until the space limitation is relieved. User Response: Notify the Strobe system programmer to clean up and reorganize the file. If a Strobe-XCF group exists, the system programmer must shut down all members of the StrobeXCF group before attempting to clean up and reorganize the file. For specific instructions, see the Strobe Installation and Customization Guide. STR6811I UNEXPECTED RESPONSE FROM SYSTEM sysname Explanation: Strobe received a response message that it cannot process from the system sysname. In some cases, the response message is associated with a measurement request from a system that has since timed out and, in that case, is preceded by STR6808E. System Action: Strobe discards the response from system sysname, and follows this message with STR6812I, which contains the discarded message. User Response: Retry the function. The unexpected response may have indicated a time out due to poor performance. But, if the problem persists, notify the Strobe system programmer. STR6812I string address offset data Explanation: Strobe writes this message to the Strobe log in certain diagnostic situations. System Action: Strobe continues processing. User Response: None required. STR6813W QRE DATA AND SRE DATA ARE INCONSISTENT FOR REQUEST rrrr Explanation: The request element for request rrrr is not active. The Strobe request element (SRE), however, identified this request as active. This message appears in the Strobe log only. System Action: Strobe is unable to process the updates to the request because the measurement session for that request has already begun. User Response: None required. Messages Produced by Strobe 3-149 STR6814E COMMUNICATION FAILURE, MESSAGE BROADCAST IS INCOMPLETE - OUT-OF-SYNC CONDITION MAY EXIST Explanation: Strobe sent a message to other members of a Strobe-XCF group. At least one of the members, however, did not receive the message. In some cases, this message indicates that the requests are out of synchronization with other members of a Strobe-XCF group. System Action: At this time, Strobe is not able to determine if the system is still active. User Response: Notify the Strobe system programmer. The system programmer can determine whether the system is still active by checking the Strobe log, or by issuing the SHOW MEMBERS command. If the system has terminated, no response is necessary. If the system is still active, however, the requests on that system are potentially out of synchronization. In this case, the system programmer must either issue the RESYNC command or stop and restart Strobe. For more information, see the Strobe Installation and Customization Guide. STR6815E END REQUEST TO SYSTEM sysname FAILED Explanation: Strobe attempted to send a message to another member of the Strobe-XCF group, but was not able to deliver the message to the group member (system sysname). System Action: Strobe is not able to send the message to system sysname. This message is preceded by message STR6806E, which contains the return and reason codes for the crosssystem coupling facility (XCF) that failed (IXCMSGO). Strobe also provides additional diagnostic information for this situation by writing message STR6812I to the Strobe log. User Response: Notify the Strobe system programmer. The system programmer can determine the cause of the failure by referencing the return and reason codes contained in STR6806E, and by viewing the STR6812I message associated with this request in the Strobe log. STR6816W STROBE UNABLE TO PROCESS REQUEST rrrr, DUE TO error Explanation: Strobe is unable to continue processing request rrrr because it encountered the error identified in error. error can be: • QUEUE READ ERROR. Strobe encountered an error attempting to read the Strobe queue dataset. • OPEN ERROR. Strobe encountered an error attempting to open the Strobe queue dataset. • INVALID SRESTAT. Strobe identified an error in the status of a measurement request. • BLDACEE ERROR. Strobe encountered an error attempting to build an Accessor Environment Element (ACEE) control block. System Action: Strobe does not process the measurement request. User Response: Notify the Strobe system programmer. STR6817W STROBE ENCOUNTERED A DUMMY QRE FOR REQUEST nnnn Explanation: The new request, request number nnnn, which was added from one of the systems in the Strobe-XCF group, does not contain any measurement request information. It is a dummy request that Strobe uses as a place holder. System Action: Strobe reads the request but does not update its local work area. User Response: Contact Compuware Customer Support. STR6818W REQUEST nnnn NOT QUEUED ON SYSTEM sysname - INSUFFICIENT ACCESS AUTHORITY Explanation: Request nnnn is not queued on system sysname because you are not authorized to measure the job on the system. System Action: If the job specified in request nnnn executes on system sysname, it will not be measured. User Response: To run a Strobe measurement request on system sysname, the Strobe system programmer or security administrator must grant you access to the system in the security data base for that system. STR6819W STROBE IS NOT LICENSED ON THIS PROCESSOR TYPE - CONTACT COMPUWARE CORPORATION FOR LICENSING INFORMATION Explanation: Strobe is not licensed for the type of processor on which you attempted to run Strobe. 3-150 Strobe Messages Guide System Action: Strobe does not operate in this environment. User Response: For more information about running Strobe on this type of processor, contact Compuware Corporation. STR6820W SR/SM TIMER SET FAILED. STIMERM RC = rc Explanation: Strobe was unable to set the session requester/session manager timer. IBM’s STIMERM service issues a return code of rc. System Action: Strobe will continue processing but because the SR/SM Timer is not set, in the event of a failure, Strobe will not follow normal recovery procedures. User Response: Refer to the documentation for IBM’s STIMERM macro to determine the meaning of the return code. Check the Strobe log for messages and, if necessary, notify the Strobe system programmer. STR6821E CVU NOT FOUND FOR IN Explanation: A call was made to the Strobe SVC by a component that has not logged in to Session Manager. System Action: The call was aborted. Strobe processing continues. User Response: Contact Compuware Customer Support. STR6822E routine text Explanation: text. System Action: An internal processing error has occurred in routine routine and is described in Strobe does not process the request. User Response: This message contains important diagnostic information. Contact Compuware Customer Support. STR6823I TOO MANY {JOBS|PROCESSES} TO DISPLAY - FIRST number {JOBS|PROCESSES} DISPLAYED Explanation: You requested to view all active jobs or processes on a specific system. However, the number of active jobs or processes on the system exceeds the maximum number that the cross-system coupling facility (XCF) can pass to Strobe from the specified system. System Action: Strobe displays the maximum number of active jobs or processes that XCF sends from the requested system, identified as number. User Response: STR6824I SEND OPERATION FAILED; REASON: text Explanation: be: • • • • • • None required. The SEND operation failed and the possible reasons are given in text. text can REQUEST NOT FOUND UNKNOWN SEND REQUEST TYPE DELETE INPUT INVALID ACCESS DENIED ACEE BUILD FAILED SEND TIME-OUT. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR6825W STROBE INITIALIZATION TIMEOUT ON SYSTEM sysname1 WAITING FOR RESPONSE FROM SYSTEM sysname2 Explanation: Strobe initialization processing on system sysname1 sent an XCF signal to Strobe on system sysname2 and did not receive a response within the interval that Strobe allows. System Action: Strobe attempts to send the signal to another member of the Strobe-XCF group. If there are no more members to signal or if the members signaled do not respond, then Strobe will not be initialized on system sysname1 and will issue message STR6245S - STROBE INITIALIZATION TERMINATED - UNABLE TO COMMUNICATE WITH STROBE-XCF GROUP. Messages Produced by Strobe User Response: 3-151 Notify the Strobe system programmer. STR6826W FOR STROBE INITIALIZATION ON SYSTEM sysname1, ERROR IN GRPPARMS PROCESSING ON SYSTEM sysname2 RC=rc Explanation: Strobe initialization processing on system sysname1 sent an XCF signal to system sysname2 requesting information, but the routine GRPPARMS issued a return code rc, indicating that it was unable to provide the data. System Action: Strobe attempts on system sysname1 to send the signal to another member of the Strobe-XCF group. If there are no more members to signal or if the members signaled do not respond, then Strobe will not be initialized on system sysname1 and will issue message STR6245S. User Response: Notify the Strobe system programmer. STR6827W FOR STROBE INITIALIZATION ON SYSTEM sysname1, UNABLE TO PROCESS GRPPARMS DATA FROM SYSTEM sysname2 Explanation: Data that routine GRPPARMS passed from system sysname2 could not be accessed by Strobe on system sysname1. System Action: Strobe attempts to send the signal to another member of the Strobe-XCF group. If there are no more members to signal or if the members signaled do not respond, then Strobe will not be initialized on system sysname1 and will issue message STR6245S. User Response: STR6828E Notify the Strobe system programmer. routine - ddname operation FAILED: RC vsamrc RSNC vsamrsnc Explanation: Strobe routine routine attempted to perform an operation operation on ddname ddname. The operation failed with the VSAM return code vsamrc and the VSAM reason code vsamrsnc. System Action: Strobe continues processing. User Response: Notify the Strobe system programmer. The system programmer can investigate the problem and clean up and reorganize files if necessary. STR6829I TRIGGER REQUEST nnnn AND ANY RELATED REQUESTS WILL BE DELETED Explanation: As requested, Strobe will delete the trigger request, identified by nnnn, for a concurrent set. Because you are deleting the trigger request, any related requests in the concurrent set will also be deleted. STR6141I will confirm the deletions. System Action: Strobe processes the request. User Response: None required. STR6830I RELATED REQUEST nnnn WILL BE DELETED Explanation: Because you deleted the trigger request for a concurrent set, all of the related requests will be deleted. This message will occur for each related request, listing each related request individually and identifying the request by its request number nnnn. STR6141I will confirm the deletions. System Action: Strobe processes the request. User Response: None required. Messages Returned by the Migration Utility STR6831S NEITHER SYSQUEUE NOR SYSGROUP ALLOCATED, MIGRATION TERMINATED Explanation: System Action: Neither of the required input datasets is allocated. The migration utility terminates. User Response: Verify that the JCL is correct and that it points to the correct input dataset names. If you need assistance, contact Compuware Customer Support. 3-152 Strobe Messages Guide STR6832S ddname NOT ALLOCATED, MIGRATION TERMINATED Explanation: Because the dataset referred to by ddname ddname is not allocated, the migration was terminated. System Action: The Strobe migration utility terminates. User Response: Verify that the output datasets are allocated and that the JCL is correct. STR6833S ddname DATA SET NOT EMPTY, MIGRATION TERMINATED Explanation: Because the dataset referred to by ddname ddname is not empty, it will not be used in the migration. The migration is terminated. System Action: The migration utility terminates. User Response: Allocate a new dataset to be used in the migration. STR6834S ddname fnct ERROR, RC=rc RSNC=rsnc Explanation: VSAM returned an error while processing a request for the dataset referred to by ddname ddname while performing function fnct. The VSAM return code is rc; the VSAM reason code is rsnc. System Action: The migration utility terminates. User Response: Look up the return codes and reason codes in the DFSMS/MVS Macro Instructions for Data Sets manual. If you need assistance, contact Compuware Customer Support. For diagnostic purposes, save the snap dump. STR6835E ddname error reason - SYSTEM = system SRE = sre nnn Explanation: The dataset referred to by ddname ddname encountered the error described in error reason. The system is system and the Strobe request element number is sre nnn. System Action: Strobe does not process the record in error but continues processing other records in the dataset. User Response: If you need assistance, contact Compuware Customer Support. For diagnostic purposes, save the snap dump. STR6836I ddname DATA SET SUCCESSFULLY MIGRATED FROM RELEASE vrn1 TO RELEASE vrn2 Explanation: Strobe successfully migrated the dataset referred to by ddname ddname from version release number vrn1 to version release number vrn2. System Action: The migration utility completes successfully. User Response: None required. STR6837W ddname DATA SET MIGRATED FROM RELEASE vrn1 TO REPLACE vrn2 RC = rc Explanation: Strobe migrated the dataset referred to by ddname ddname from version release number vrn1 to version release number vrn2 with a return code of rc. System Action: The migration utility completes with errors, which are documented in additional messages. User Response: STR6838W If you need assistance, contact Compuware Customer Support. ddname DATA SET EMPTY Explanation: System Action: The migration utility found an input dataset to be empty. The migration utility continues processing other datasets. User Response: Verify that the JCL is pointing to the correct input datasets and rerun the migration utility. STR6839S ddname MIGRATION FROM RELEASE rel NOT SUPPORTED BY UTILITY VERSION vrn Explanation: The dataset referred to by ddname ddname is at a release level rel that is not supported by the current level of the migration utility, vrn. System Action: The migration utility terminates. User Response: Verify the JCL, and check that you are executing the latest version of the migration utility. Messages Produced by Strobe STR6840S 3-153 INTERNAL PROCESSING ERROR - error reason Explanation: error reason. The migration utility encountered the internal processing error described in System Action: The utility terminates. User Response: snap dump. Contact Compuware Customer Support. For diagnostic purposes, save the STR6841E ddname GROUP PROCESSING ERROR: nnn ELEMENT RECORDS EXIST, xxx EXPECTED GRPOWNER = grpowner GROUP = groupname Explanation: The migration utility detected an error processing the dataset referred to by ddname ddname. Strobe expected xxx element records in group groupname. However, nnn element records actually exist. The group owner is given in grpowner. System Action: The utility does not migrate any of the records in the group that experienced the error but continues processing the next group of records. User Response: If you cannot determine the cause of this problem, contact Compuware Customer Support. For diagnostic purposes, save the snap dump. STR6842E ddname error reason - GRPOWNER = grpowner GROUP = groupname ELEMENT = element Explanation: The migration utility encountered an error while processing element element in group groupname for grpowner grpowner. The dataset is referred to by ddname ddname, and the error is described in error reason. System Action: The utility does not migrate any of the records in the group that experienced the error but continues processing the next group of records. User Response: If you cannot determine the cause of this problem, contact Compuware Customer Support. For diagnostic purposes, save the snap dump. STR6843S error text Explanation: System Action: Because of the reason displayed in error text, the migration will be terminated. The migration utility terminates. User Response: Verify that the parameter specified is correct and rerun the migration utility. If you require assistance, contact Compuware Customer Support. STR6844I PARM = parmname1 [parmname2, parmname3...] Explanation: The name of the input parameters is parmname1. Additional input parameters, if present, are given in parmname2, parmname3... System Action: None. User Response: None required. STR6845I ddname type RECORDS WRITTEN: nnnn Explanation: The migration utility has successfully written nnnn records of dataset name ddname and type type. System Action: None. User Response: None required. STR6846I ddname DATA SET SUCCESSFULLY COPIED Explanation: The migration utility successfully copied dataset ddname. System Action: None. User Response: None required. STR6847S ddname NO RECORDS FOUND error reason Explanation: The migration utility found no records for dataset name ddname because of the error described in error reason. System Action: Strobe does not process the request. 3-154 Strobe Messages Guide User Response: Verify that you entered the correct combination of parameters. You can use the LIST parameter to list the contents of the QUEUE and Group datasets. STR6848S MIGRATION FOR RELEASE rel NOT SUPPORTED BY UTILITY VERSION vrn Explanation: The current version of the Strobe migration utility, vrn, does not support migration from or to release rel. System Action: The migration utility does not process the request. User Response: You either used an out-of-date version of the migration utility or specified an incorrect release number. Correct the error and resubmit the request. STR6849I DATA SET ONLY COMPLETED REQUESTS WILL BE MIGRATED WHEN CREATING A TEST QUEUE Explanation: The Strobe migration utility will migrate only completed requests when migrating to a test queue dataset. System Action: None. User Response: None required. STR6850S STROBE MIGRATION TERMINATED, TARGET RELEASE xxxx IS OLDER THAN THE SOURCE RELEASE yyyy Explanation: The Strobe release xxxx designated as the target of a migration (OUTREL) was more recent than release yyyy, which was designated as the source of the migration (INREL). This message is preceded by STR6844I, which specifies the pertinent parameters. System Action: The STRBCMIG program terminated without attempting the migration. User Response: Correct the input parameters in the JCL used to initiate the migration utility. STR6851E MIGRATION FUNCTION TO SAME RELEASE LEVEL NOT SUPPORTED. USE COPY FUNCTION OF STRBCMIG. Explanation: The Strobe release designated as the target of a migration (OUTREL) was the same as the release designated as the source of the migration (INREL). The migration function applies only to generating queue and group datasets for releases that are newer than the release of the source datasets. System Action: The STRBCMIG program terminated without attempting the migration. User Response: Change the primary input parameter (the PARM=function) to COPY, make sure that you specify the other parameters required with COPY, and resubmit the migration utility program. STR6853I IRB TIMER NOT SET Explanation: The Strobe IRB (Interruption Request Block) initial implant process attempted to set a timer which failed to set. System Action: MVS has encountered an internal problem with Strobe’s timer request. Strobe processing continues anyway. User Response: Notify the Strobe system programmer. If the problem persists, contact Compuware Customer Support. STR6854I IRB TIMER EXPIRED Explanation: Strobe could not implant into the address space within a fixed time interval (5 second default) because MVS marked the job as non-dispatchable. Strobe failed to implant in the target address space. System Action: Strobe aborts the implant process. The system or job may be too busy to allow Strobe into the address space. However, sometimes this will be resolved by retrying the job. User Response: If retrying does not resolve the issue, notify the Strobe system programmer. The default interval is a 5 second wait period before the IRB timer expires. If this is insufficient, the MAINTP1 parameter may be set to provide a longer wait time interval. MAINTP1 may be changed from zeros (the default) to 00000400 which sets the wait time to 30 seconds, or to 00000200 which sets the wait time to 60 seconds. You will need to recycle Strobe in order to re-read the parameter. Messages Produced by Strobe STR6855I 3-155 IRB HAS STARTED BUT NOT COMPLETED Explanation: The Strobe initial implant processing under an IRB (Interruption Request Block) did not complete. System Action: Strobe most likely will abort the implant process. The system or job may be too busy to allow Strobe into the address space. However, sometimes this will be resolved by retrying the job. User Response: If retrying does not resolve the issue, notify the Strobe system programmer. The default interval is a 5 second wait period before the IRB timer expires. If this is insufficient, the MAINTP1 parameter may be set to provide a longer wait time interval. MAINTP1 may be changed from zeros (the default) to 00000400 which sets the wait time to 30 seconds, or to 00000200 which sets the wait time to 60 seconds. You will need to recycle Strobe in order to re-read the parameter. STR6861I AUTOCICSMAX CANNOT BE GREATER THAN AUTOMAX. SETTING AUTOCICSMAX TO XX Explanation: The AUTOCICSMAX parameter value is greater than the value of the AUTOMAX parameter. User Response: Strobe sets the value of the AUTOCICSMAX parameter to the value of the AUTOMAX parameter. User Response: STR6863W None. STROBE FOR UNIX SYSTEM SERVICES IS NOT LICENSED Explanation: Each time Strobe initializes, you will receive this message, if BPXBATCH=YES (default value) in the Strobe parameter dataset, and Strobe for UNIX System Services is not licensed. System Action: Strobe sets BPXBATCH=NO and continues to initialize. User Response: If you do not want to see this message, set BPXBATCH=NO in the parameter dataset. If you want to license Strobe for UNIX System Services, contact your Compuware sales representative. STR6867I ORIGINAL BATCH REQUEST nnnn MARKED COMPLETE FOR TARGET JOB jobname Explanation: For the target job jobname Strobe has marked the original request, request number nnnn, complete because all designated steps were measured or the job has ended. The original request is a template request from which Strobe creates requests for each of the executing steps in this batch measurement. The original request itself is not associated with a measurement session. System Action: None. User Response: None required. STR6870W BPXBATCH CLONE LIST FOR REQUEST nnnn IS FULL Explanation: Strobe was measuring a USS application that involved over 20 internal processes. nnnn is the Strobe request number. System Action: Strobe continues to measure all processes that are still active. User Response: If BPXBATCH is being used to run a script that is process-intensive (i.e., generates more that 20 processes), then—if possible—split the script into smaller steps and remeasure using multiple BPXBATCH steps. STR6873E {STEP1 | MULTIPLE STEPS} NOT SUPPORTED FOR USS BPXBATCH Explanation: You submitted an Add Queued request for BPXBATCH or AOPBATCH and specified one of the following for STEP: • STEP1. This value is not permitted. STEP1 is used by IBM as an internal stepname for UNIX System Services. • Multiple steps or *ALL. You must specify a single stepname. System Action: Strobe does not process the request. User Response: Specify a permitted value for STEP and resubmit the request. 3-156 Strobe Messages Guide STR6875E STROBE USS BPXBATCH EXITS NOT DISABLED BY STROBE; CANNOT BE RE-ENABLED BY STROBE Explanation: The ENABLEUSSX command was issued, but Strobe for UNIX System Services has not been disabled. System Action: None. User Response: None required. STR6876I STROBE USS BPXBATCH EXITS SUCCESSFULLY Explanation: An operator ENABLEUSSX or DISABLEUSSX command was issued. System Action: exits. Strobe for UNIX System Services successfully enabled or disabled service User Response: None required. STR6877E INVALID WRITE_SMF120_X PARM; SET PARM WAS=NO TO DISABLE OR SEE STROBE INSTALL GUIDE FOR CRITICAL WRITE_SMF120_X FACTS Explanation: Your site is licensed for Strobe for WebSphere Application Server, and your Strobe PARMLIB keyword WAS is set to Yes. However, a valid value for the WRITE_SMF120-x parameter as specified in the message text has not been specified. System Action: Strobe will not initialize. User Response: If your site does not need to produce Strobe for WebSphere Application Server reports, change the PARMLIB keyword WAS to NO. If your site does need Strobe for WebSphere Application Server reports, set WRITE_SMF120_x to a valid value and restart Strobe. For information on customizing Strobe for WebSphere Application Server, see the Strobe Installation and Customization Guide. STR6878W STROBE USS BPXBATCH IS NOT ACTIVE. CANNOT STROBE USS EXITS. Explanation: An operator ENABLEUSSX or DISABLEUSSX command was issued for Strobe for UNIX System Services, but Strobe for UNIX System Services exits are not active. System Action: collected. Strobe continues processing, but no UNIX measurement data will be User Response: None required. STR6879W MISMATCH BETWEEN REQUEST NUMBER AND SMW REQID , SWM FUNCTION CODE IS . Explanation: An error has occurred in internal Strobe processing. System Action: The function being processed will be terminated. User Response: Contact Compuware Customer Support. STR6880W Parameter missing, Explanation: action taken: • • • • A parameter in the Strobe PARMLIB was not supplied. Strobe displays the No defaults supplied Global Monitor set to NO GM_iStrobe set to NO GM_Vantage set to NO System Action: Strobe continues to initialize with degraded function. User Response: Consult the Strobe Installation and Customization Guide for details on setting parameters. Supply the missing parameters. STR6881W dynaTrace interface failed rc xxxx Explanation: System Action: Unable to connect to dynaTrace server. Strobe continues. User Response: Review dynaTrace connection parameters in PARMLIB. Supply and/or correct the missing parameters Messages Produced by Strobe 3-157 Messages Returned by the Session Management Facility for AutoStrobe The session management facility returns the following messages in response to Strobe commands, writing them to the SYSPRINT dataset and to an operator’s terminal when the request originated there. STR6900E ENTRIES STARTTIME AND STARTDATE PARAMETERS DO NOT CONTAIN THE SAME NUMBER OF Explanation: You specified the STARTTIME and STARTDATE parameters on the ADD or SUBMIT operation, but did not specify a matching number of entries for each parameter. You must specify one STARTTIME parameter for each STARTDATE parameter. System Action: Strobe does not process the ADD or SUBMIT request. User Response: Ensure that you have an equal number of entries for the STARTTIME and STARTDATE parameters and then resubmit the ADD or SUBMIT operation. STR6901I ELEMENT jobname ADDED FOR GROUP groupname Explanation: A new request group element, specified by jobname, has been added to the request group groupname. System Action: Strobe adds the new request group element to the request group. User Response: None required. STR6902E ADDGRP ERROR - ELEMENT jobname GROUP groupname Explanation: Strobe may have been unable to save the request (identified by jobname) as a request group element in the request group groupname. System Action: information. Strobe may not have processed the request. The log contains additional User Response: programmer. Check the Strobe log for additional messages and notify the Strobe system STR6903I ELEMENT jobname CHANGED FOR GROUP groupname Explanation: You changed one of the request group elements (identified by jobname) in the request group groupname. System Action: Strobe modifies the request group element. User Response: None required. STR6904E CHANGE ERROR ELEMENT jobname GROUP groupname Explanation: Strobe may have been unable to modify the request group element (identified by jobname) in the request group groupname. System Action: information. Strobe may not have processed the request. The log contains additional User Response: programmer. Check the Strobe log for additional messages and notify the Strobe system STR6905I GROUP groupname DELETED Explanation: Strobe processed a DELGRP operation, which specified that the request group groupname be deleted. System Action: Strobe deletes the request group from the request group dataset. User Response: None required. STR6906E GROUP groupname NOT FOUND Explanation: Strobe cannot find any request group that matches the name specified in groupname. Either you specified the wrong request group name, or the request group does not exist. 3-158 Strobe Messages Guide System Action: Strobe does not process the request. User Response: request. If you specified the incorrect request group name, correct and resubmit the STR6907E DELETE ERROR FOR GROUP groupname [ELEMENT jobname] Explanation: Strobe may have been unable to process a Delete operation. The request group specified is groupname. If the delete specified elements in a request group, those elements are identified by jobname. System Action: Strobe may not have deleted the request group element. The log contains additional information. User Response: programmer. STR6908I Check the Strobe log for additional messages and notify the Strobe system ELEMENTnnn DELETED IN GROUP groupname Explanation: Strobe processed a DELGRP operation and deleted the request group element(s) that were specified by sequence number nnn from the request group specified in groupname. System Action: Strobe deletes the request group element. User Response: None required. STR6909E ELEMENT jobname IN GROUP groupname NOT FOUND Explanation: Strobe cannot find any request group element that matches the name specified in job jobname and group groupname. Either you specified the wrong request group element name, or the request group element does not exist. System Action: Strobe does not process the request. User Response: If you specified an incorrect request group element name, correct and resubmit the request. STR6910I {STR6910I|STR6910W | STR6910E| STR6910S} GROUP groupname SUBMITTED, RC=rc Explanation: The request group specified by groupname has been submitted for processing. The return code is rc. The error severity indicator (I, W, E, or S) depends on the return code. System Action: Strobe processes the submit request. User Response: None required. If the return code is not zero, check the Strobe log for additional messages. STR6911E GROUP SUBMISSION ERROR FOR GROUP groupname Explanation: Strobe may have been unable to process a SUBMIT operation for the request group groupname. System Action: Strobe may not process the request. The log contains additional information. User Response: Check the Strobe log for messages and resubmit the request. If the problem persists, notify the Strobe system programmer. STR6913I GROUP groupname COPIED TO newgroup Explanation: You copied the request group groupname, and all of its associated request group elements, to the new request group specified in newgroup. System Action: Strobe creates the new request group and populates it with copies of the request group elements from request group groupname. User Response: STR6914E None required. GROUP groupname COPY ERROR Explanation: Strobe may not have been able to copy the request group groupname. System Action: Strobe may not have processed the request. The Strobe log contains additional information. User Response: programmer. Check the log for additional messages and notify the Strobe system Messages Produced by Strobe STR6915I 3-159 groupname, num of elements, num of subs, credate, last mod date, last sub, grpowner Explanation: Strobe returns this message in response to a LISTGRP operation. Strobe lists the name of the request group (groupname), the number of request group elements in the request group (num of elements), the number of times the request group has been submitted (num of subs), the date the request group was created (credate), the date that the request group was last modified (last mod date), the last time the request group was submitted (last sub), and the group owner (grpowner) of the person who created the request group. System Action: Strobe continues processing. User Response: None required. STR6916I REQUEST nnnn CLONED FROM xxxx ORIGINAL REQUEST yyyy {AUTOMEASURE|AUTOMONITOR|BPXBATCH} Explanation: Strobe has created a measurement request based on one of the following: • An ADD request that specified a list of job steps to be measured using the PROGRAM, STEP, NUMBER parameters • An ADD request that specified that all steps of the job be measured using the *ALL parameter • An ADD request that contained a schedule • An ADD request that specified AutoMonitor and the criteria for AutoMonitor have been met • A new or changed load module on the AutoMeasure list has been executed  When you submit a single measurement request to measure multiple steps of a job, Strobe initiates a measurement session for each job step you specified. When the first measurement session is initiated, Strobe creates subsequent measurement sessions by copying or cloning the previous measurement request. This message displays the number of the new request (nnnn) as well as the numbers of the original measurement request (yyyy) and the previous request from which the measurement parameters were cloned (xxxx). This message appears for both the original request and the cloned request. System Action: Strobe uses the parameters specified in the ORIGINAL REQUEST (yyyy) to create the subsequent or cloned request (nnnn). User Response: STR6917I None required. CLONING OF REQUEST jobname nnnn TERMINATED Explanation: Strobe issues this message when it has encountered an error in cloning target job jobname for Strobe request number nnnn. This message accompanies STR6106E. System Action: requests. Strobe processes the current request but does not process subsequent User Response: None required. STR6918I MEASURING USS COMMAND: Explanation: A measurement request has been cloned to measure the specified command command name. The command name will be up to 128 bytes long. System Action: Measurement continues. User Response: None required. STR6919I SSI FUNCTION function {ENABLED | DISABLED} Explanation: The Strobe subsystem function function is either enabled or disabled. Strobe uses subsystem function function to perform end-of-task processing or delete processing for multistep requests. System Action: None. User Response: None required. 3-160 Strobe Messages Guide STR6921I NNNN ENTRIES REMOVED FROM SCHEDULE - DATE AND TIME LESS THAN CURRENT Explanation: You submitted a measurement request or a request group with one or more invalid entries for the STARTDATE and the STARTTIME parameters. Strobe removes these entries from the schedule. The values for these parameters must be a future date and time. The number of invalid entries is identified by nnnn. System Action: Strobe removes the invalid entries and processes the request. User Response: None required. STR6922E NO TRIGGER FOUND FOR CONCURRENT SET concurrentname GROUP groupname Explanation: You designated one or more request group elements in a request group as related requests in a concurrent set, but have not yet specified a trigger request. The concurrent set name is concurrentname and the request group name is groupname. System Action: Strobe does not create the concurrent set association between the requests. User Response: Specify a request group element as the trigger request for the concurrent set. STR6923I HALTED TRIGGER JOB jobname CONCURRENT SET concurrentname NOT ACTIVE, PROCESSING Explanation: You submitted a request group for processing containing concurrent set concurrentname. The trigger request jobname for the concurrent set is specified as an Add Active request group element. The target job for the trigger request is not currently active. System Action: Strobe does not process the SUBMIT request and deletes the requests. User Response: Either resubmit the request group when the target job for trigger request jobname is active, or change the trigger request to an Add Queued request group element. STR6924I ORIGINAL MULTISTEP REQUEST nnnn MARKED COMPLETE FOR TARGET JOB jobname Explanation: For the target job jobname Strobe has marked the original request, request number nnnn, complete because all designated steps were measured or the job has ended. The original request is a template request from which Strobe creates requests for each of the executing steps in this multistep measurement. The original request itself is not associated with a measurement session. System Action: None. User Response: None required. STR6926I ONLY TWO ENTRIES REMAIN IN SCHEDULE REQUEST nnnn ORIGINAL REQUEST xxxx Explanation: Only two entries remain for the scheduled measurement request or the scheduled request group. The remaining (deferred) requests are contained in xxxx and are from the original request nnnn. This message alerts you that entries in your scheduled request are about to run out. System Action: Strobe continues processing. User Response: None required. If you want to continue to measure automatically with Strobe on a schedule, you need to set up another scheduled measurement request. STR6927W INVALID DATE/TIME ENTRIES FOUND IN SCHEDULE. xxxx ENTRIES REMOVED FROM REQUEST [nnnn] Explanation: You submitted a measurement request or a request group for a request with one or more invalid entries for the STARTDATE and the STARTTIME parameters. Strobe removes xxxx entries from the schedule. The values for these parameters must be a future date and time or the current date with a future time. The future time must be at least three minutes in the future from when the system receives the request. If present, the request number is nnnn. System Action: Strobe removes the invalid entries and continues processing. User Response: None required. STR6928E NO VALID DATE/TIME ENTRIES FOUND IN SCHEDULE REQUEST [nnnn] MARKED COMPLETED Explanation: No valid entries for the STARTDATE and the STARTTIME parameters remain in the scheduled request. The values for these parameters must be a future date and time (or the current date with a future time). The future time must be at least two minutes in the future Messages Produced by Strobe 3-161 from when the system receives the request. The request is marked completed. If present, the request number is nnnn. System Action: Strobe marks the scheduled request as completed and continues processing. User Response: None required. STR6929I UNUSED REQUEST nnnn WILL BE DELETED Explanation: In a multistep measurement request, the step for request nnnn never ran, so the measurement for request nnnn never initiated. This request will be deleted. System Action: Strobe deletes the request. User Response: None required. STR6930E GROUPNAME PARAMETER MUST BE SPECIFIED FOR THIS REQUEST Explanation: You specified a SUBMIT operation to submit a request group for processing but did not specify the group name using the GROUPNAME parameter. System Action: Strobe does not process the request. User Response: Resubmit the request using the GROUPNAME parameter. STR6931I IGNORED SCHEDULE PARAMETERS NOT SUPPORTED ON GROUP REQUESTS - PARAMETERS Explanation: You specified an ADDGRP operation to save a request as a request group element in a request group. However, you have also specified some of the scheduling parameters, such as STARTDATE and STARTTIME. These parameters are not allowed on the ADDGRP operation, because the request is being saved in the group, not submitted for processing. System Action: parameters. Strobe saves the request in the request group, but ignores the scheduling User Response: None required. If you want to submit the request group with a schedule, use the SUBMIT operation, as described in the Strobe User Guide. STR6932I REQUEST xxxx BEING TERMINATED BY TRIGGER REQUEST nnnn Explanation: The primary (trigger) request of the concurrent set (nnnn) terminated the related request (xxxx) in a concurrent set. In concurrent set processing, the primary, or trigger, request controls the initiation and termination of all the related requests in the concurrent set. System Action: Strobe marks the requests as completed and continues processing. User Response: None required. STR6933I ADDGRP FAILED - REQUEST MUST BE AN ADD ACTIVE Explanation: The Add Group request was unsuccessful. You attempted to specify an Add Queued request group element as a related request in a concurrent set incorrectly. You attempted to enter this request as an Add Queued, but it must be an Add Active. System Action: Strobe does not process the request. User Response: group element. Resubmit the request, ensuring that the request is an Add Active request STR6934W SUBMIT FAILED FOR RELATED CONCURRENT SET concurrentname GROUP groupname, REQUESTS NOT SUBMITTED Explanation: The SUBMIT operation for concurrent set concurrentname failed. This concurrent set is a member of group groupname. System Action: Strobe terminates all of the related requests in the concurrent set. User Response: Examine the Strobe log to determine the cause of the failure, correct the problem, and resubmit the request group. STR6935E LIST FAILED FOR GROUP groupname STORAGE UNAVAILABLE RC=rc Explanation: You attempted to list the elements in the request group identified by groupname. However, Strobe cannot complete the request because of insufficient storage. The return code, rc, holds the contents of register 15 from IBM’s GETMAIN macro. 3-162 Strobe Messages Guide System Action: Strobe does not display the contents of the request group. User Response: programmer. Check the Strobe log for additional messages and notify the Strobe system STR6936E SUBMIT FOR GROUP groupname FAILED MAX REQUESTS WOULD BE EXCEEDED Explanation: You have attempted to submit the request group, identified by groupname, for processing. However, Strobe could not process the request group because the total number of requests on the Strobe system would exceed the maximum amount specified by the Strobe system programmer at installation time. System Action: Strobe does not submit the request group. User Response: Notify the Strobe system programmer. STR6937E NUMBER OF GROUP ELEMENTS NOW EXCEEDS MAX REQUESTS. GROUP groupname CANNOT BE SUBMITTED Explanation: The total number of request group elements in the request group groupname exceeds the maximum number of allowable request group elements. This number is defined as the maximum number of requests allowed on the system. System Action: Strobe cannot submit the request group for processing. User Response: Delete some of the request group elements in request group groupname. STR6938W SEQUENCE NUMBER EXCEEDS 999 FOR GROUP groupname - GROUP MUST BE RESEQUENCED Explanation: You attempted to add request elements to group groupname. However, the sequence numbers for the request group have already reached 999. As you add elements to a group, Strobe assigns a unique sequence number to each request element. The maximum sequence number that Strobe will assign is 999. You cannot add to the group once Strobe has assigned this number. The sequence numbers associated with each request element within a group do not change even if you delete request elements from the group. For Strobe to supply new sequence numbers, you must first delete some request elements and then copy the group to a new group name. Strobe will then assign new sequence numbers to the request elements. This message is followed by STR6939W. System Action: Strobe will not process the request. User Response: Delete the unwanted request elements from group groupname and follow the instructions in STR6939W. STR6939W COPY GROUP groupname TO A NEW GROUP Explanation: To resequence the numbers assigned to request elements in the group, copy the group to a new name. This message is preceded by STR6938W. System Action: Strobe processes the request. User Response: Copy groupname to a new group name. STR6940W IMPLANT FOR SCHEDULED REQUEST FAILED - REQUEST MARKED COMPLETE Explanation: Strobe attempted to run a scheduled Add Active measurement request at the dates, times, number of retry intervals, and number of retry attempts that you specified, but Strobe could not find the specified job. Although the term “implant” refers to the Strobe measurement request in the Strobe address space, this message could be generated by any of the following reasons: • The job that Strobe was to measure never became active. • Strobe was not running in the address space. • The implant for the measurement was never established. System Action: Strobe changes the status of the current element from deferred to completed. Strobe was unable to measure this element in the group, however, it will attempt to measure other elements in the group according to the submissions and retry intervals that you specified. User Response: None required. You cannot produce a Performance Profile from the request (even though it is identified as completed) because there is no measurement data. Messages Produced by Strobe STR6941S STROBE SSI FUNCTION function FAILED PROCESSING JOB jobname AT time date Explanation: date date. Strobe function function failed while processing job jobname at time time and System Action: The subsystem interface becomes disabled. User Response: Notify the Strobe system programmer. STR6942S 3-163 MULTISTEP NOT ALLOWED - AUTOSTROBE NOT INSTALLED ON SYSTEM sysname Explanation: Strobe cannot process a request to measure multiple steps of a job because the AutoStrobe is not installed on system sysname. System Action: Strobe will process the first specified job step in the measurement request. User Response: None required. To install AutoStrobe, notify the Strobe system programmer. STR6943S CONCURRENT NOT ALLOWED - AUTOSTROBE NOT INSTALLED ON SYSTEM sysname Explanation: Strobe cannot process all measurement requests of a concurrent set because AutoStrobe is not installed on system sysname. System Action: Strobe processes the trigger request of the concurrent set but will not process any related requests. User Response: To install AutoStrobe, contact Compuware Customer Support. STR6944E NOT AUTHORIZED TO ISSUE commandname COMMAND FOR {OWNER= | NEWOWNER=} username Explanation: You tried to issue an AutoStrobe group processing command commandname for the owner or new owner identified in username. The Strobe security interface determined that you do not have authority to issue this command for groups created by this owner or new owner. System Action: Strobe will not process the request. User Response: Do not issue this command for username. The Strobe administrator can issue this command for this user. STR6945E SYSGROUP DATASET ERROR, RTN: routine, RC= vsamrc RSNCD=vsamrsnc Explanation: The session manager encountered an error executing routine routine while accessing the SYSGROUP dataset. The VSAM return code is vsamrc, and the VSAM reason code is vsamrsnc. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR6946E groupname MULTIPLE TRIGGERS FOUND FOR CONCURRENT SET concurrentname GROUP Explanation: You designated more than one trigger request for related requests in a concurrent set. The concurrent set name is identified by concurrentname and the request group name is identified by groupname. System Action: Strobe does not create the concurrent set association among the requests. User Response: concurrent set. Specify only one request group element as the trigger request for the STR6947E TIMEOUT FOR COMMAND commandname, PROCESSING HALTED RC=rc Explanation: System Action: information. Command commandname has timed out with return code rc. Strobe may not have processed the command. The log contains additional User Response: Check the Strobe log for additional information and notify the Strobe system programmer. 3-164 Strobe Messages Guide STR6948W ROUTINE routinename SENSED SESSION MANAGER TIMEOUT ROUTINE COMPLETED SUCCESSFULLY Explanation: This message accompanies STR6947E. Although you received a timed out message for the command, the routine routinename has completed successfully. System Action: Strobe successfully processed the request. User Response: Notify the Strobe system programmer. STR6949I STROBE ACTIVE FOR ASIDS FOR JOB ON SYSTEM . Explanation: The maximum number of active measurements for jobname on system have been initiated. System Action: Subsequent measurement requests for this jobname will not be initiated until one of the active measurements stops. User Response: STR6950W None required. AUTOMEASURE IS INVALID WITHOUT AUTOMONITOR. SETTING AUTOMEASURE=NO Explanation: The AUTOMEASURE installation parameter is set to YES, but the AUTOMONITOR installation parameter is set to NO. AutoMeasure requires that the AUTOMONITOR installation parameter be set to YES in the parameter dataset. System Action: The AUTOMEASURE installation parameter is set to NO and Strobe continues to initialize. User Response: YES. STR6951E To activate AutoMeasure, set the AUTOMONITOR installation parameter to DELETE REJECTED - REQUEST IS AUTOMEASURE TEMPLATE REQUEST Explanation: A DELETE command has been issued to delete the AutoMeasure template, but TYPE=AUTOMEASURE|AUTOMEAS was not specified in the command. System Action: The DELETE command fails. User Response: To delete the AutoMeasure template, specify TYPE=AUTOMEASURE|AUTOMEAS in the command. STR6952E CANNOT ADD BLANK TARGET Explanation: An attempt was made to specify a JAVA targeting request for which the JAVA target type was valid but the actual target name was missing. For example, JAVA=(JAVATGT=('P')) . System Action: The measurement request is failed. User Response: To specify JAVA targeting, the operand of the JAVATGT= keyword must be of the form JAVATGT=('Xtarget.name'), where X is the JAVA target type (see message STR6916E on page 3-159), and target.name is the JAVA entity that corresponds to the specified target type. Examples: JAVA=(JAVATGT=('Pcom.userwritten.package')) JAVA=(JAVATGT=('CUserWrittenJavaClass')) JAVA=(JAVATGT=('MexecUserSQLQueryMethod')) STR6953E Target type must be P, C or M Explanation: An attempt was made to specify a JAVA targeting request for which the JAVA target type was invalid. For example, JAVA=(JAVATGT=('Ocom.userwritten.package')) . System Action: The measurement request is failed. User Response: To specify JAVA targeting, the operand of the JAVTGT= keyword must be of the form JAVATGT=('Xtarget.name'). X is the JAVA target type, which must be P, C, or M (that is, Package, Class, or Method). This value must be in uppercase. target.name is the JAVA entity that corresponds to the specified target type. Messages Produced by Strobe 3-165 Examples: JAVA=(JAVATGT=('Pcom.userwritten.package')) JAVA=(JAVATGT=('CUserWrittenJavaClass')) JAVA=(JAVATGT=('MexecUserSQLQueryMethod')) STR6954I Strobe Health Checks are Enabled Explanation: The Strobe Local Health Checks initialized successfully. System Action: Strobe Local Health Checks are scheduled for execution. User Response: None required. STR6955W Installation of the Strobe Health Check Exit Routine Failed. Strobe Health Checks may be limited. Explanation: System Action: The Strobe Local Health Checks did not initialized successfully. Strobe Local Health Checks are not scheduled for execution. User Response: Verify that the IBM Health Checker for z/OS is active and that Strobe modules are available to the IBM Health Checker for z/OS address space. Messages Returned by Strobe/ISPF Strobe/ISPF produces the following messages. The short version of each message appears in the ISPF message line at the top right corner of a panel. The long version of the message, shown below the short version, appears when you press the Help function key. STR7010E INVALID DISPOSITION. THE VALID SAMPLE DATA SET DISPOSITIONS ARE ‘CATLG’ AND ‘KEEP’ Explanation: System Action: You selected an invalid dataset disposition. Strobe/ISPF does not process the measurement request. User Response: Specify either CATLG or KEEP in the DISP field on the Strobe - Add Active Request, Strobe - Add Queued Request, or Strobe - Change Queued Request panel, or on the corresponding Strobe - Batch-Submission panel. STR7013E INVALID JOBNAME. ENTER UP TO 8 ALPHANUMERIC CHARACTERS - THE 1ST MUST NOT BE NUMERIC Explanation: System Action: You specified the JOBNAME field incorrectly. Strobe/ISPF does not process the measurement request. User Response: Specify a jobname from 1 to 8 alphanumeric or national characters. The first character must be alphabetic or national. STR7014E INVALID SESS. DURATION. SESSION DURATION MUST BE A NUMBER FROM 1 to 1440 Explanation: You specified the SESSION DURATION field incorrectly. This field is used to estimate in minutes the duration of the measurement session. System Action: Strobe/ISPF does not process the measurement request. User Response: Specify a number from 1 to 1440. If you leave the field blank, Strobe uses the default of 1 minute. STR7015E NUM SAMPLES OUT OF RANGE. NUMBER OF SAMPLES REQUESTED SHOULD BE BETWEEN 1,000 AND 150,000 Explanation: System Action: You specified the NUMBER OF SAMPLES field incorrectly. Strobe/ISPF does not process the measurement request. User Response: Specify a value between 1,000 and 150,000 or clear the field to accept the Strobe/ISPF default value of 10,000 samples. 3-166 Strobe Messages Guide STR7016E FINAL SESS. ACT. INVALID. FINAL SESSION ACTION MUST BE ‘Q’, ‘S’, OR ‘C’ (IF NO CICS DATA COLLECTOR) Explanation: You specified the FINAL SESSION ACTION field incorrectly. This field indicates the action to be taken when the target sample size is reached in the last measurement session. You cannot specify a final session action of C if the CICS data collector is invoked. System Action: Strobe/ISPF does not process the measurement request. User Response: Specify Q to Quit sampling and terminate the request, S to Stop sampling but leave the measurement session active, or C to take no action and continue sampling. If you leave the field blank, Strobe uses the default value of Q for an Add Active request or C for an Add Queued request. STR7017E SHORT NAME REQUIRED. ENTER A SHORT NAME Explanation: A name of 12 characters or less is required to identify your output. System Action: Strobe does not process your request. User Response: Use a name of 12 characters or less. STR7018E MSG DS ALLOC FAILURE. RC= rc; ERC/IRC= erc/irc; TEMP DATA SET WITH SSMF MSGS Explanation: The operating system returned a nonzero return code rc while attempting to allocate a temporary dataset to display the Strobe messages. The error reason code is erc, and the information reason code is irc. System Action: The Strobe log will not display with the Strobe/ISPF Browse Log function or the .CVM command. User Response: Notify the Strobe system programmer. STR7019E INVALID OPTION/COMMAND. CHECK THE SPECIFICATION IN THE OPTION OR COMMAND FIELD Explanation: You selected an option that the panel does not support or entered a command that is invalid. System Action: Strobe/ISPF does not process the option or command. User Response: Select one of the options listed on the panel or enter a valid command. STR7020I REQ nnnn {ACTIVE|SUSPENDED|QUEUED|TERMINATED|SCHEDULED} [RC=rc] {A STROBE REQUEST HAS BEEN ADDED FOR jobname|THE STROBE REQUEST WAS TERMINATED FOR jobname} Explanation: You submitted a measurement request. Strobe/ISPF reports the request number (nnnn) and status in the short message field. If the request was submitted successfully, the jobname appears in the long message field. Otherwise, the return code appears in the short message field and the appropriate error message appears in the long message field. System Action: Strobe successfully processed the request and is waiting for the next request. User Response: None required. STR7021E SELECT AN OPTION. OPTION FIELD IS BLANK - SELECT AN OPTION FROM THE OPTIONS ON PANEL Explanation: You did not specify a processing option for the request. System Action: None. User Response: Enter the option code in the OPTION field and resubmit the request. STR7022E WORK DS ALLOC FAILURE. RC=rc; ERC/IRC=erc/irc; ddname Explanation: Strobe/ISPF encountered a nonzero return code, rc, while attempting to allocate a work dataset, ddname, for foreground processing. The error reason code is erc and the information reason code is irc. System Action: Strobe/ISPF cannot allocate the work dataset. User Response: Notify the Strobe system programmer. Messages Produced by Strobe 3-167 STR7023E REQUIRED FIELD. PROGRAM NAME OR STEPNAME/STEPNUMBER OR PROCSTEP.STEPNAME REQUIRED Explanation: You identified the target job incorrectly in the PROGRAM or STEP field of the Strobe - Add Queued Request panel. System Action: Strobe/ISPF does not process the measurement request. User Response: You must specify one or more of the job identification operands: program name, stepname, stepnumber, and procstepname.stepname. Resubmit the request, and specify the job step or program you want to measure.  If SCHEDULE REQUEST is an option on the Strobe - Add Queued panel, AutoStrobe is installed and you can measure multiple steps of a job. To do this, clear the PROGRAM and STEP fields and press Enter. The Strobe - Add Queued Request - Multiple Steps panel will appear. On this panel, you can fill in the program names, step names, or step numbers that you would like to measure. To measure all the steps of a job, specify *ALL in the STEP field or select Option 4 on the Strobe - Add Queued Request - Multiple Steps panel. STR7024E INVALID PROGRAM NAME. ENTER UP TO 8 ALPHANUMERIC CHARACTERS - THE 1ST MUST NOT BE NUMERIC; LAST CHARACTER MAY BE AN ASTERISK Explanation: System Action: You have entered an invalid program name in the PROGRAM field. Strobe/ISPF does not process the measurement request. User Response: Specify a program name of 1 to 8 alphanumeric or national characters in the PROGRAM field. The first character must be alphabetic or national. The last character may be an asterisk, which acts as a wildcard. A single asterisk is not valid. STR7025E INVALID STEPNAME. SPECIFY EITHER THE RELATIVE STEP NUM (1-255) OR A VALID STEPNAME Explanation: You entered an invalid step in the STEP field of the Strobe - Add Queued Request panel or you have chosen Option 2 on the Strobe - Add Queued Request - Multiple Steps panel and specified the name of one or more steps or step.procsteps incorrectly. System Action: Strobe/ISPF does not process the measurement request. User Response: Supply a relative step number between 1 and 255, or a stepname, or a procstepname and stepname. The stepname or procstepname must contain from 1 to 8 alphanumeric characters. The first character must be alphabetic or national. The three national characters are @, #, and $.  If you want to measure multiple steps of a job, clear the PROGRAM and STEP fields and press Enter. This will bring you to the Strobe - Add Queued Request - Multiple Steps panel on which you can fill in the program names, step names, or step numbers that you would like to measure. To measure all the steps of a job, specify *ALL in the STEP field or select Option 4 on the Strobe - Add Queued Request - Multiple Steps panel. STR7026E LINES/PAGE OUT OF RANGE. LINES PER PAGE SHOULD BE FROM 45 TO 80 Explanation: You specified an invalid number of lines per page in the LINES/PAGE field. This field controls the number of lines printed on each page of the Performance Profile. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Enter a value between 45 and 80 or clear the field to accept the Strobe default of 60. STR7027I JOBNAME MAX NUM OF JOBS SELECTED. TO ADD MORE JOBS REPEAT REQUEST WITH BLANK Explanation: System Action: You chose more than 32 Active jobs from the Active Job Selection List. Strobe/ISPF will process the first 32 jobs selected. User Response: To process additional jobs, add the first 32 Add Active requests, clear the JOBNAME field on the last Strobe - Add Active Request panel, and select up to 32 more jobs to process from the Strobe - Active Job Selection List panel. Repeat this process until you have selected all desired jobs. 3-168 Strobe Messages Guide STR7028E STROBE ERROR. STROBE message Explanation: Strobe detected an error while processing a measurement request. The long message field provides the Strobe message. System Action: Strobe does not process the measurement request. User Response: To view all the session management facility messages, enter .CVM in the option field or command line, and then notify the Strobe system programmer. STR7029E PROFILE ALLOC ERROR. RC= rc; ERC/IRC= erc/irc; dsname Explanation: The operating system returned a nonzero return code rc while Strobe/ISPF attempted to allocate a dataset, dsname, for foreground processing of the Strobe Performance Profile. The error reason code is erc and the information reason code is irc. Strobe normally stores a version of the Performance Profile with an 80-character format in this dataset. System Action: request. Strobe does not allocate the dataset or process the Performance Profile User Response: Notify the Strobe system programmer. STR7030W STROBE WARNING. STROBE message Explanation: Strobe detected an error and issued this warning message while processing a measurement request. The long message field gives the entire message. System Action: options. Strobe processes the measurement request but may not apply all specified User Response: line. To view all the Strobe messages, enter .CVM in the option field or command STR7031E INTERNAL ERROR modname info - NOTIFY STROBE SYSTEM PROGRAMMER Explanation: A Strobe/ISPF module modname encountered an internal error. Information about the error appears in info. This summary includes the return code, if applicable. System Action: Strobe/ISPF does not perform the requested action. User Response: Notify the Strobe system programmer. STR7032E USE S AS A SELECT CODE. USE S TO THE LEFT OF THE ENTRY TO INCLUDE IT IN YOUR SELECTION LIST Explanation: You specified the selection code incorrectly. System Action: Strobe/ISPF does not process the request. User Response: Use S to select an entry in the list. STR7033I STROBE ENV NOT ACTIVE. STROBE message Explanation: Strobe is not active. If Strobe issued only one message, it is displayed in the long message field. Otherwise, all messages are displayed in the Strobe log. System Action: Strobe/ISPF cannot process the option. You cannot select Add Active and Add Queued requests, request groups (applicable only if you have AutoStrobe), status, or the log utility function. You can select other Strobe/ISPF options that do not require the Strobe session management facility. These options include: setting user defaults, creating a Performance Profile, using the Indexer, and viewing messages and changes. User Response: STR7034S Ask the Strobe system programmer to activate the Strobe environment. SSMF ERRORCHECK THE LOG FOR ADDITIONAL INFORMATION Explanation: You selected an option that requires a component of Strobe, the Strobe session management facility, but this facility issued a return code of 20 (severe error) on a previous call. System Action: Strobe/ISPF cannot process the option. You cannot select Add Active and Add Queued requests, request groups (applicable only if you have AutoStrobe), status, or the log utility function. You can select other Strobe/ISPF options that do not require the Strobe session management facility. These options include: setting user defaults, creating a Performance Profile, using the Indexer, and viewing messages and changes. Messages Produced by Strobe 3-169 User Response: Use the ISPF Browse function (not Strobe/ISPF) to examine the Strobe log for additional information. If you cannot browse the Strobe log, notify the Strobe system programmer. STR7035E RESOLUTION OUT OF RANGE. RESOLUTION SHOULD BE BETWEEN 1 AND 9999 Explanation: You specified an invalid value in the RESOLUTION field. The value in this field determines the size of the codeblocks into which Strobe will subdivide long procedures for detailed reporting. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Enter a value between 1 and 9999 or clear the field to accept the Strobe default of 64 bytes. STR7036S SSMF ERROR. AN UNRECOVERABLE FAILURE HAS OCCURRED Explanation: Strobe/ISPF encountered a return code of 20 (severe error) while trying to call the Strobe session management facility. The Strobe session management facility cannot recover from this failure. System Action: All Strobe session management facility processing stops. User Response: To view all the Strobe messages, enter .CVM in the option field or command line. Notify the Strobe system programmer. STR7037E ENTER 'B' OR 'F'. YOU MUST SPECIFY (B)ACKGROUND OR (F)OREGROUND Explanation: System Action: You did not specify a processing option in the option field. Strobe/ISPF does not process the request. User Response: To generate a batch job, specify B for background processing. Multiple requests for Performance Profiles or map datasets are generated as steps in the same job. To view the Performance Profile or create the map dataset online, specify F for foreground processing. STR7038E DYNAMIC ALLOCATION ERROR. RC= rc; ERC/IRC= erc/irc; {dsname [member]|ddname} Explanation: The operating system returned a nonzero return code rc while attempting to allocate the dataset specified by the dataset name dsname or the data definition name ddname. If the dataset is a partitioned dataset, the member name is member. The error reason code is erc and the information reason code is irc. System Action: Strobe/ISPF does not allocate the dataset. User Response: Notify the Strobe system programmer. STR7039E SYSIN DATA SET NOT FOUND. SYSIN DATA SET dsname NOT FOUND Explanation: A SYSIN dataset, dsname, is specified, but the SYSIN dataset is not cataloged. System Action: Strobe/ISPF cannot produce a Performance Profile until either a cataloged dataset is specified or the SYSIN field is cleared to indicate that a SYSIN dataset is not needed. User Response: STR7040E AND 9999 Specify a valid SYSIN dataset name in the SYSIN field or clear the field. INVALID REQ NUMBER. REQUEST NUMBER MUST BE A NUMBER BETWEEN 1  Explanation: You specified an invalid request number. System Action: Strobe/ISPF does not process the request. User Response: Enter a numeric value from 1 to 9999. STR7041E BASELINE OUT OF RANGE. DETAIL BASELINE MUST BE A VALUE FROM 0 TO 99 Explanation: You specified an invalid percentage in the DETAIL BASELINE field. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Specify a value between 0 and 99. 3-170 Strobe Messages Guide STR7042E DEFAULT PROFILE ERROR. RC = rc; ERC/IRC = erc/irc; BLANK OR CHOOSE ANOTHER Explanation: You chose Option G from the STATUS panel, but Strobe/ISPF has encountered a nonzero return code, rc, while attempting to allocate the sample dataset. The error reason code is erc and the information reason code is irc. System Action: Strobe cannot create a Performance Profile from the dataset. User Response: Clear the SAMPLE DATA SET NAME field and press Enter to bypass the failing dataset or enter another sample dataset name in this field. Notify the Strobe system programmer. STR7043E UNABLE TO LOCATE SSR. progname WAS NOT FOUND IN A LINKLIST Explanation: Strobe/ISPF is unable to load the session requester because it did not find the program progname. System Action: Strobe/ISPF cannot process any option that requires the session requester. User Response: Notify the Strobe system programmer. There has probably been an installation error. STR7044E WRONG SSR VERSION. SSR RELEASE NUM IS ccc; STROBE/ISPF RELEASE NUM IS sss Explanation: The release number (NUM), ccc, of a component of Strobe, the Strobe session requester (SSR), does not match the release number of Strobe/ISPF, sss. System Action: Strobe/ISPF cannot process any option requiring SSR. User Response: Notify the Strobe system programmer. There has probably been an installation error. STR7045E UNIT & VOLUME REQUIRED. THE UNIT AND VOLUME ARE REQUIRED FOR AN UNCATALOGED DATA SET Explanation: You specified an uncataloged dataset but have not provided a unit name, volume serial number, or both. System Action: Strobe/ISPF cannot allocate the dataset. User Response: Specify the unit name and volume serial number of the device on which the dataset is located. STR7046E VOLUME IS INVALID. VALID VOLUME IS 1 TO 6 ALPHANUMERIC, SPECIAL OR NATIONAL CHARACTERS Explanation: System Action: You specified an invalid volume serial number in the VOLUME field. Strobe/ISPF does not process the request. User Response: Specify a valid volume serial number. It must be 1 to 6 alphanumeric, special, or national characters. The three national characters are @ # $. The eleven special characters are the “blank” character , . / ’ ) ( * & = +. STR7047E UNABLE TO FIND progname. progname NOT FOUND IN LINKLIST Explanation: Strobe/ISPF cannot find the program progname in the link list dataset, and your Strobe system programmer did not specify a Strobe load library on the UI_STRBLOAD parameter in the Strobe PARMLIB member. System Action: Strobe/ISPF does not process the request. User Response: Ask the Strobe system programmer to specify the Strobe load library containing this program on the UI_STRBLOAD parameter in the Strobe PARMLIB member or to copy the load module into a link list dataset. STR7048E UNABLE TO FIND progname. progname NOT IN loadlib OR LINKLIST Explanation: Strobe/ISPF cannot find the program progname in a link list dataset or in the dataset loadlib specified on the UI_STRBLOAD parameter in the Strobe PARMLIB member. System Action: Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. Messages Produced by Strobe 3-171 STR7049I SPECIFY JCL DISPOSITION. JCL FOR JOB STEPS CREATED - SELECT OPTION TO PROCESS OR 'END' Explanation: You pressed End at the Strobe - Produce A Performance Profile panel or from the Strobe - Index To Create a Map Dataset panel after submitting requests for background processing. System Action: Strobe /ISPF places the job control statements for the requests in a temporary dataset and displays the Strobe - Select Option For Job Stream panel. User Response: Select the desired option from this panel or press End to cancel the background requests. STR7050E NO SELECTIONS MADE. NO DATA SETS WERE SELECTED FROM DATA SET LIST JUST PRESENTED Explanation: You did not select a dataset to process after you requested a list of datasets available for Performance Profile processing. System Action: Strobe /ISPF does not process the request. User Response: Request the dataset list again and select the datasets to process by placing an S to the left of the dataset names, and press Enter, or press End to cancel the request. STR7051I NO REQUESTS FOUND. NO MEASUREMENT REQUESTS EXIST [FOR OWNERID ownerid] Explanation: No current measurement requests meet the selection criteria you specified. If you specified an owner ID on the STATUS panel, it is displayed in the variable ownerid. This message is issued when you perform any of the following operations under the conditions specified: – Select Option 3 (STATUS) on the Strobe Options menu, and no requests were found that match the owner ID in the OWNERID MASK field. – Refresh the STATUS panel, and the measurement requests previously displayed no longer exist. – Attempt to refresh a sample dataset list created through the STATUS panel, and the request numbers you selected no longer exist. – Attempt to display or refresh the sample dataset list from the Strobe - Produce a Performance Profile panel, but Strobe found no measurement requests that match the owner ID on the STATUS panel. System Action: Strobe/ISPF does not display the request or sample dataset list. User Response: If you want to display requests, change the owner ID mask in the OWNERID MASK field of the STATUS panel to match the owner ID of the requests. If the request that you want to display is deleted, search the Strobe log for messages about the request and a record of the sample datasets created for the request. STR7052E INVALID PERCENTAGE VALUE. PERCENTAGE MUST BE BETWEEN 00.0 AND 99.9 Explanation: You specified an invalid percentage. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Specify a value between 00.0 and 99.9. STR7053E COMPRESS ID INVALID. PREFIX MAY BE UP TO 8 CHARS - THE FIRST CHARACTER CANNOT BE NUMERIC Explanation: You specified an incorrect prefix under the COMPRESS option on the Strobe Detail For a Performance Profile panel. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Specify a valid prefix and resubmit the request. Valid prefixes contain three alphanumeric characters, beginning with an alphabetic or national character. Following the prefix, the other seven characters may be alphabetic, numeric, national, or the global search character asterisk (*). The global search character specifies a shortened prefix field for grouping and should be used in the second or third position, not the first. 3-172 Strobe Messages Guide STR7054E MISSING MEMBER NAME. A PARTITIONED DATA SET IS SPECIFIED BUT NO MEMBER NAME IS SUPPLIED Explanation: NAME field. System Action: You specified a partitioned dataset without a member name in the DATA SET Strobe/ISPF does not process the Performance Profile request. User Response: Enter a valid partitioned dataset with a member name or enter a valid sequential dataset without a member name. STR7055E ERROR AUTHORIZATION ERROR. DELETE OF dsname REC'D PROBABLE AUTHORIZATION Explanation: You tried to delete a request and its associated sample datasets using Option X from the STATUS panel, but you are not authorized to delete the sample dataset, dsname. System Action: Strobe does not delete the request or any of the associated sample datasets. User Response: Verify that you have the authority to delete the sample datasets. STR7056E WORKPRI VAR NOT SPEC'D. PRIMARY SPACE ALLOCATION IS NOT SPECIFIED FOR ISPF VAR WORKPRI Explanation: The Strobe system programmer did not specify a value for the parameter UI_WORKPRI (primary space allocation) in the Strobe PARMLIB member. System Action: Strobe dynamic allocation will fail unless your installation has established default space allocation parameters. User Response: Ask the Strobe system programmer to specify the parameter UI_WORKPRI. STR7057I SAMPLE DSN(S) NOT DLET. SAMPLE DSN NOT FOUND/NOT DELETED FOR REQ nnnn; REQ NUMBER DELETED Explanation: You tried to delete a request, nnnn, and its associated sample datasets using Option X from the STATUS panel, but Strobe/ISPF has found no sample datasets associated with this request. System Action: Strobe deletes only the request number nnnn. User Response: None required. STR7058E USE 'Y' TO SELECT LANG. TO SELECT A LANGUAGE, ENTER 'Y' NEXT TO THE PROGRAM LANGUAGE NAME Explanation: You entered an invalid selection code next to a program language name. System Action: Strobe/ISPF does not process the Indexer request. User Response: Select a language by entering a Y to the right of the program language name. STR7059E LIST DATA SET REQ'D. SPECIFY A LIST DATA SET NAME IN THE FIRST FIELD Explanation: You did not specify a dataset name in the first INPUT: Compiler SYSPRINT Datasets field on the Strobe - Index To Create a Map Dataset panel. This field must name a dataset containing the SYSPRINT listing produced by a compiler or an assembler. System Action: Strobe/ISPF does not process the Indexer request. User Response: Specify a dataset name in the first INPUT: Compiler SYSPRINT Datasets field. STR7060E DATA SET MEMBER NAME NOT VALID. A MEMBER NAME IS NOT ALLOWED ON A SEQUENTIAL Explanation: You specified a sequential dataset with a member name in parentheses. A member name cannot be specified for this dataset. System Action: Strobe/ISPF does not process the Indexer request. User Response: Remove the member name from the sequential dataset or specify a partitioned dataset. Messages Produced by Strobe 3-173 STR7061E INVALID SPECIFICATION. CICS DC MUST BE SPECIFIED AS Y FOR THE CICS OPTIONS TO BE USED Explanation: You requested a CICS processing option without selecting the CICS data collector on the Strobe - Data Collectors panel. System Action: invoked. Strobe cannot process any CICS options until the CICS data collector is User Response: panel. Specify Y next to the CICS data collector on the Strobe - Data Collectors STR7062I MAP DATA SET CREATED. THE STROBE MAP DATA SET HAS BEEN CREATED IN dsname Explanation: You specified foreground indexing of a SYSPRINT dataset for a map dataset. The name of the dataset is dsname. System Action: Strobe successfully completed and created a map dataset in the foreground. User Response: If you requested the creation of a map dataset through the Profile option, you can press Enter to supply the map dataset to the Reporter. Otherwise, you can supply the map dataset later when you produce a Performance Profile. STR7063E INDEXER CMPLTD RC=rc. indexer message Explanation: You selected foreground processing from the Strobe - Index To Create a Map Dataset panel. System Action: Strobe Indexer returned a nonzero return code, rc. User Response: Press Help key to view the corresponding Indexer error message in the long message field. Find the message in Strobe Messages Guide (this manual) and read the indicated response. STR7064E TEMP SYSIN DS ALLOC ERR. RC= rc; ERC/IRC= erc/irc; dsname Explanation: The operating system returned a non-zero return code, rc, while attempting to allocate a temporary dataset for the Reporter operands specified on the Strobe - Produce a Performance Profile panel. The error reason code is erc and the information reason code is irc. System Action: Strobe does not allocate the dataset named dsname. Strobe cannot complete the request to create a Performance Profile. User Response: Notify the Strobe system programmer. STR7065E PROGRAM LANGUAGE REQ'D. ENTER 'Y' NEXT TO THE PROGRAM LANGUAGE OF THE SYSPRINT DATA SETS Explanation: You did not specify a program language. System Action: Strobe/ISPF does not process the Indexer request. User Response: Enter a Y next to the language of the programs you want to index. STR7066E SELECT ONLY 1 LANGUAGE. SELECT ONLY ONE LANGUAGE PER MAP DATA SET Explanation: You selected more than one program language name on the Strobe - Index To Create a Map Dataset panel. System Action: Strobe/ISPF does not process the Indexer request. User Response: Enter a Y next to the language of the programs you want to index. You can specify only one language for each map dataset. To index programs with different source languages, create multiple map datasets. STR7067E ENTER REQ NUM OR JOBNAME. SPECIFY EITHER REQUEST NUMBER OR JOBNAME FOR THE CHANGE REQUEST Explanation: You either specified both a jobname and a request number or neither the jobname nor the request number. System Action: Strobe does not process the change for your request. User Response: Specify either the jobname or the request number (but not both) to identify the request you wish to change. 3-174 Strobe Messages Guide STR7068E SYSPRINT ALLOC ERROR. RC=rc; ERC/IRC= erc/irc; dsname Explanation: Strobe encountered an error when it attempted to dynamically allocate dataset dsname with the user input on the Strobe - Produce a Performance Profile panel or the Strobe Index To Create a Map Dataset panel. The operating system returned a non-zero return code, rc, an error reason code, erc, and an information reason code, irc. System Action: Strobe/ISPF does not allocate the dataset. User Response: Check for errors in the unit or volume specification. If necessary, consult IBM’s Authorized Assembler Programming Guide manual, which documents dynamic allocation service’s return codes and reason codes. If this information does not help you to resolve the problem, notify the Strobe system programmer. If you are using Storage Management Subsystem (SMS), be sure that the unit and volume specifications comply with SMS rules. STR7069E ENTERED OPTION/PARM CONFLICT. OPTION 2 REQUIRED FOR PARAMETER CHANGE(S) Explanation: You specified values in the SESSION DURATION, TARGET SAMPLE SIZE, or FINAL SESSION ACTION fields on the Strobe - Change Request panel, but selected an option other than 2 in the OPTION field. You can specify these values only when selecting Option 2. System Action: Strobe/ISPF does not process the change for your request. User Response: Select Option 2 or clear the SESSION DURATION, TARGET SAMPLE SIZE, and FINAL SESSION ACTION fields before selecting a different option. STR7070I PROFILE GENERATED. THE STROBE PROFILE [dsname] IS CREATED Explanation: Strobe successfully created a Performance Profile through foreground processing. Strobe encountered no warnings or errors. The name of the dataset that contains the Profile is dsname. (If a dataset has not been specified in the DATA SET NAME field on the Strobe - Produce a Performance Profile panel, then dsname does not appear.) System Action: Strobe produces a Performance Profile. User Response: None required. STR7071I PROFILE CMPLTED RC= rc . A RETURN CODE OF rc WAS RECEIVED FROM progname Explanation: The program progname sent a nonzero return code, rc, to Strobe/ISPF. System Action: Strobe/ISPF displays the messages returned by the Reporter. If the return code is less than the severe error value of 12, Strobe also produces a Performance Profile. User Response: If the return code (rc) is less than 12, view the Performance Profile. Otherwise, view the messages and take the corrective action indicated. STR7072E COMPRESS FIELD ERROR. A COMPRESS PREFIX AND GROUP NAME MUST BE SPECIFIED TOGETHER Explanation: You did not specify both a prefix and a group name under the COMPRESS option on the Strobe - Detail For a Performance Profile panel. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Specify both a prefix (of up to eight characters) and a group name (of up to seven characters). STR7073I JCL GENERATED. nnn SSMF CONTROL STATEMENTS GENERATED FOR BATCHSUBMISSION Explanation: You specified at least one batch-submission action. System Action: Strobe/ISPF wrote nnn job control statements to the SYSIN dataset to execute Strobe on another system. User Response: Select Option 7 to submit the control statements, or press F3 to discard them. STR7074E INVALID REQ NUM/JOBNAME. FIELD DOES NOT CONTAIN A VALID REQUEST NUMBER OR A VALID JOBNAME Explanation: You specified an invalid jobname or request number on the Strobe - BatchSubmission List/Delete Request panel. System Action: Strobe/ISPF does not produce commands for the list or delete operations. Messages Produced by Strobe 3-175 User Response: Specify a number between 1 and 999, or specify a 1- to 8-character jobname consisting of alphanumeric or national characters; the first character cannot be numeric. STR7075E INVALID SPECIFICATION. VALID OPTIONS ARE 'Y' OR 'N' Explanation: You specified a value other than Y or N in the field shown by the cursor. System Action: Strobe/ISPF does not process the request. User Response: Specify Y in the field to select the desired option. STR7076E JOBNAME REQUIRED. A JOBNAME MUST BE SPECIFIED FOR THE SELECTED OPTION Explanation: Strobe/ISPF requires a jobname to process the request. System Action: Strobe/ISPF does not process the request. User Response: Enter a valid jobname. STR7077I JOBNAME NOT FOUND. THE SPECIFIED JOBNAME COULD NOT BE FOUND IN THE ACTIVE JOB LIST Explanation: longer active. The job you selected from the Strobe - Active Job Selection List panel is no System Action: Strobe/ISPF does not process the request. User Response: selection. To update the ACTIVE JOB SELECTION LIST, press Enter without making a STR7078E UNABLE TO LOCATE DSN. LOCATE RC=4 FOR dsname Explanation: The operating system returned a return code of 4 (warning) while attempting to retrieve information from a catalog for dataset dsname. System Action: Strobe/ISPF cannot allocate the dataset. User Response: error. Notify the Strobe system programmer. There has probably been a cataloging STR7079E UNABLE TO OPEN LIBRARY. THE OPEN FOR THE STROBE LOAD LIBRARY WAS UNSUCCESSFUL Explanation: Strobe/ISPF cannot open the Strobe unauthorized load library. The dataset name of the unauthorized Strobe library that contains the Strobe Reporter and Indexer programs is specified on the parameter UI_STRBLOAD in the Strobe PARMLIB member. System Action: Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. STR7080E INVALID STATUS TYPE. ENTER 'Q', 'A', 'C', [’D’] OR BLANK Explanation: You have entered an invalid type in the STATUS TYPE field on the Strobe Batch-Submission List/Delete Request panel. Valid types are: Q to list queued requests A to list active requests C to list completed requests D to list deferred requests Blank to list all requests System Action: Strobe/ISPF does not produce control statements for the LIST operation. User Response: Specify a valid type. STR7081E STROBE/ISPF ABEND. STROBE message text Explanation: An ABEND occurred during Strobe/ISPF execution.  Information about the ABEND appears in the long message text. You may review additional information by browsing the Strobe log or entering the .CVM command in the OPTION field. 3-176 Strobe Messages Guide System Action: Strobe/ISPF attempts to restart processing at the Strobe Options menu. If Strobe/ISPF cannot recover, then Strobe/ISPF processing terminates. User Response: STR7082E Notify the Strobe system programmer. UNABLE TO OPEN SYSIN. UNABLE TO OPEN SYSIN DCB Explanation: Strobe cannot open the SYSIN dataset used to pass report operands to the Reporter in the foreground Strobe - Produce a Performance Profile panel. You specified this data on the Strobe - Detail For a Performance Profile panel or with the &STRSYSIN variable on the Strobe - Default Options panel. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Ensure that the dataset name on the panel is valid. If it is, or if you have not specified a dataset name, notify the Strobe system programmer. STR7083E progname ABEND Sxxx. progname ABENDED WITH AN xxxx Explanation: A Strobe program, progname, terminated abnormally with a system code of xxxx. The program is the STROBEDT, the report reformatter STROBEDS, or an Indexer. System Action: Strobe/ISPF does not process the request. User Response: If the Reporter has terminated abnormally, verify the sample dataset name.  If an Indexer has terminated abnormally, verify the compiler SYSPRINT dataset name and the programming language specified on the Strobe - Index To Create a Map Dataset panel.  If the region size is 4096KB or less, increasing the region size may correct the problem.  Notify the Strobe system programmer. STR7084E UNIT NAME REQUIRED. A UNIT NAME IS REQUIRED TO ALLOCATE THE DATA SET Explanation: You did not specify a unit name. System Action: Strobe cannot allocate the dataset. User Response: Enter a unit name in the UNIT field. STR7085I JCL GENERATED. ppp PROFILE STEP(S) AND iii INDEXER STEP(S) GENERATED Explanation: Strobe generated ppp job steps to create Strobe Performance Profiles and iii job steps to create map datasets. System Action: Strobe/ISPF stores the job control statements in a temporary dataset until you save, submit, or cancel them. User Response: Select Option 1 to submit the job, or select Option 2 or 3 to save the job control statements in a permanent dataset. To edit the job stream, select Option 2. STR7086E NO SAMPLE DATA SETS. NO SAMPLE DATA SETS EXIST [FOR OWNERID ownerid] Explanation: You requested the Sample Data Set list by clearing the SAMPLE DATA SET NAME field, but no sample datasets are available. If an owner ID has been specified on the STATUS panel in the OWNERID MASK field, it is ownerid. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Select a completed request that has associated sample datasets, or change the owner ID to display additional requests. STR7087I ENTERED NO CHANGES MADE. A CHANGE REQUEST WAS SELECTED BUT NO CHANGES WERE Explanation: System Action: You submitted a change request but have not changed the original parameters. Strobe/ISPF does not generate a CHANGE control statement. User Response: Specify the new parameters on the change request panel and press Enter, or press End to cancel. Messages Produced by Strobe STR7088E OPTION 7 3-177 NO COMMANDS TO PROCESS. CHOOSE ANOTHER OPTION BEFORE SELECTING Explanation: You selected the JOB STREAM MENU, Option 7; however, no Strobe control statements were generated. System Action: Strobe/ISPF does not generate a job step until you request Strobe control statements from other options on the Strobe - Batch-Submission Options menu. User Response: menu. STR7089E Select one of these options or press End to return to the Strobe Options DELETE GROUP FAILED. THE GROUP WAS NOT DELETED DUE TO ERRORS Explanation: A component of Strobe, the Strobe session management facility, detected errors in the processing of the DELETE GROUP command. System Action: Strobe does not process the command. User Response: Correct the errors displayed on the browse screen and reissue the command. STR7090E FIELD MUST BE NUMERIC. THIS FIELD REQUIRES A NUMERIC SPECIFICATION Explanation: specification. You entered a nonnumeric value in a field that requires a numeric System Action: Strobe/ISPF does not process your selection. User Response: Enter a numeric value. STR7091E SORTSIZE OUT OF RANGE. THE SORT CORE SIZE VALID VALUES ARE ZERO OR FROM 12000 TO 999999 Explanation: System Action: You specified an invalid value in the SORT SIZE field. Strobe/ISPF does not process the request. User Response: Specify a number between 12000 and 999999, or select zero to accept the system default. If you clear the field, Strobe/ISPF uses the Strobe default of 999999. STR7092E INVALID OWNERID. ENTER VALID JOBNAME, OWNERID, PATTERN, OR BLANKS Explanation: System Action: You specified an invalid owner ID in the OWNERID field. Strobe/ISPF does not process your selection. User Response: To view requests submitted under one jobname or TSO owner ID, enter the jobname or owner ID consisting of alphanumeric characters. The first character must not be numeric. To view requests submitted under all jobnames or TSO owner IDs that begin with a common prefix, enter the prefix followed by the global search character asterisk (*). To view all requests, clear the field or enter only the global search character asterisk (*). STR7093E INVALID DATA SET NAME. YOUR DSNAME SPECIFICATION IS SYNTACTICALLY INCORRECT Explanation: You specified an invalid dataset name. System Action: Strobe/ISPF does not process your selection. User Response: Enter a valid dataset name. STR7094E INVALID LIST. AN SVC LIST MUST CONTAIN TWO OR MORE SVC ENTRIES SEPARATED BY COMMAS Explanation: You specified a list of SVC numbers incorrectly. System Action: Strobe/ISPF does not process the request. User Response: Separate the entries in the list of SVC numbers and ranges with commas. 3-178 Strobe Messages Guide STR7095E CANNOT ALLOCATE PDS. THE PARTITIONED DATA SET SPECIFIED MUST BE CATALOGED Explanation: You specified an uncataloged partitioned dataset in the DATA SET NAME field. System Action: Strobe/ISPF cannot allocate a new partitioned dataset. User Response: Specify either a sequential dataset or a cataloged partitioned dataset. STR7096E SPECIFY MESSAGE NUMBER. SPECIFY THE FOUR-DIGIT NUMERIC PORTION OF THE MESSAGE IDENTIFIER Explanation: You did not specify a message number in the MESSAGE NUMBER field. System Action: Strobe/ISPF does not display the message text. User Response: Enter the four-digit numeric portion of the message key. STR7097E MSG LIBRARY NOT FOUND. UNABLE TO LOCATE dsname Explanation: The library dsname, which contains the Strobe message text, is not cataloged. The Strobe error message text library must be specified on the parameter UI_STRBETXT in the Strobe PARMLIB member. System Action: Strobe/ISPF does not display the message text. User Response: Notify the Strobe system programmer. STR7098E LIB ALLOCATION ERROR. RC=rc; ERC/IRC=erc/irc; dsname Explanation: Strobe/ISPF attempted to allocate the Strobe error message text library dsname, and the operating system returned a nonzero return code, rc. The error reason code is erc and the information reason code is irc. The Strobe error message text library is specified on the parameter, UI_STRBETXT in the Strobe PARMLIB member. System Action: message. Strobe/ISPF cannot allocate the dataset or display the explanation of a User Response: Notify the Strobe system programmer. STR7099I MESSAGE NOT FOUND. NO MESSAGES WERE FOUND WITH THE MESSAGE KEY nnnn Explanation: You specified a message key for which there is no associated message text in the Strobe message library. System Action: Strobe/ISPF does not display the message text. User Response: Correctly specify the four-digit numeric portion of the message key. STR7100E PERMANENT I/O ERROR. PERM I/O ERROR OR INSUFF STORAGE - dsname Explanation: Strobe/ISPF encountered an error while reading the dataset dsname. The error indicates insufficient storage or a permanent I/O error. System Action: Strobe/ISPF stops processing. User Response: Notify the Strobe system programmer. STR7101E UNABLE TO OPEN MSG LIB. UNABLE TO OPEN THE ERROR MSG LIB - dsname Explanation: Strobe/ISPF was unable to open the Strobe message library dsname while processing a request from the Strobe - Display Message Text panel or the .M command. The Strobe error message text library is specified on the parameter, UI_STRBETXT in the Strobe PARMLIB member. System Action: Strobe/ISPF does not display the message text. User Response: Notify the Strobe system programmer. STR7102E 255 NUMBER OF COPIES INVALID. COPIES MUST BE A NUMERIC VALUE BETWEEN 1 AND Explanation: You specified an invalid number of copies in the NUMBER OF COPIES field. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Specify a number of copies that is between 1 and 255. Messages Produced by Strobe STR7103E INVALID MESSAGE NUMBER. THE ERROR MESSAGE KEY MUST BE NUMERIC Explanation: You specified an invalid message key in the MESSAGE NUMBER field. System Action: Strobe/ISPF does not display the message text. User Response: Enter the four-digit numeric portion of the message key. STR7104E PANEL 3-179 NO MAP GENERATED. MAXIMUM NUMBER OF MAP DATA SETS SPECIFIED ON THE Explanation: You specified Y in the NEW MAPS field, but all the MAP DATA SET NAMES fields are filled. System Action: Strobe/ISPF does not process the Indexer request. User Response: Delete one of the seven MAP DATA SET NAMES fields so that Strobe/ISPF can enter the new map dataset name. STR7105E MESSAGE LIB NOT SPEC'D. STROBE MESSAGE LIB DSN IS NOT SPEC'D FOR THE PARAMETER UI_STRBETXT Explanation: A dataset name for the library containing the Strobe error message texts is not specified on the parameter UI_STRBETXT in the Strobe PARMLIB member. System Action: Strobe/ISPF does not display the message text. User Response: Notify the Strobe system programmer. STR7106E DATA SET NAME REQUIRED. A DATA SET NAME MUST BE SPECIFIED WHEN OPTION 2 OR 3 IS SELECTED Explanation: You selected Option 2 or 3 to write the job stream to a dataset, but you did not specify a dataset name. System Action: Strobe/ISPF does not write the job stream to a dataset. User Response: Specify a sequential dataset or a member of an existing partitioned dataset. If the sequential dataset does not already exist, Strobe/ISPF creates and catalogs it. STR7107E OUTPUT SPECIFY MAP DSNAME. A MAP DATA SET NAME IS REQUIRED FOR THE INDEXER Explanation: You left the MAP DATA SET field blank. This field specifies a name for the map dataset produced by a Strobe Indexer. System Action: Strobe/ISPF does not process the Indexer request. User Response: Specify a fully qualified dataset name within single quotation marks. If you specify a dataset name without single quotation marks, Strobe/ISPF appends your TSO prefix or owner ID or the system-default high-level qualifier to the dataset name. STR7108E ISPF SERVICE FAILED. SERVICE servicename RC = rc IN modname Explanation: Strobe called the dialog service servicename from module modname, but the service routine failed with a return code of rc. System Action: Strobe/ISPF does not process your selection. User Response: Notify the Strobe system programmer. STR7110E NAME MEMBER NAME NOT ALLOWED. MEMBER NAME IS NOT ALLOWED IN THE DATA SET Explanation: You cannot specify a partitioned dataset for a sample dataset or a Performance Profile dataset. System Action: Strobe/ISPF does not process your request. User Response: Specify the name of a sequential dataset. STR7111E VOLUME NOT MOUNTED. dsname IS NOT AVAILABLE, MOUNT VOLUME volume Explanation: Strobe/ISPF attempted to retrieve a dataset, dsname, from the specified volume volume and the operating system returned a return code of 4 (warning). System Action: The volume is not mounted. 3-180 Strobe Messages Guide User Response: STR7112E Request that the device be mounted or specify a dataset on another volume. DATA SET NOT ON VOLUME. dsname NOT ON volume Explanation: Strobe/ISPF attempted to retrieve the dataset dsname from the specified volume volume on a direct-access storage device, and the operating system returned a return code of 8. The dataset is not cataloged on that volume. System Action: Strobe/ISPF does not process the request. User Response: Specify an existing dataset name. STR7113E VALIDATION ERROR. RC=rc ON VOLUME volume FOR dsname Explanation: Strobe/ISPF attempted to retrieve dataset dsname from volume volume on a direct-access storage device, and the operating system has returned a return code, rc, of 12 or 16 (severe errors). System Action: Strobe/ISPF does not process the request. User Response: programmer. Refer to the relevant IBM publication and notify the Strobe system STR7114W TIME OUT OCCURRED. REQ NUM NOT AVAILABLE - CHECK STATUS PANEL OR LOG FOR VERIFICATION Explanation: Strobe may have been unable to add the request. System Action: Strobe may not have processed the request. The log and STATUS panel contain additional information. User Response: Check the Strobe log for additional messages and the STATUS panel for additional information. If the request succeeded, it will appear on the STATUS panel. STR7115E CATALOG DATA SET NOT CATALOGED. dsname COULD NOT BE LOCATED IN THE SYSTEM Explanation: Strobe/ISPF attempted to retrieve dataset information from a catalog, and the operating system returned a nonzero return code. Strobe/ISPF cannot locate the dataset named dsname in the system catalog. System Action: Strobe/ISPF does not process the request. User Response: Specify an existing cataloged dataset name. STR7116E INVALID DATA SET NAME. A SYNTAX ERROR EXISTS IN THE DSNAME dsname Explanation: The operating system returned a return code of 20 (severe error) while attempting to retrieve information from a catalog by dsname. You specified an invalid dataset name. System Action: Strobe/ISPF does not allocate the dataset. User Response: Specify a fully qualified dataset name. STR7117E I/O ERROR ON CATALOG. AN I/O ERROR WAS ENCOUNTERED ATTEMPTING TO LOCATE dsname Explanation: The operating system returned a return code of 24 while attempting to locate dataset dsname. This is a permanent I/O error. System Action: Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. STR7120E CICS/IMS NOT ALLOWED. CICS AND IMS CANNOT BE SELECTED TOGETHER Explanation: You cannot select both the CICS and the IMS subsystems. Overriding the CPS or Terminal Activity Report causes CICS to be invoked; leave these fields blank if you select IMS. Strobe will automatically collect DBCTL activity in a CICS address space if both Strobe for CICS and Strobe for IMS are present. Do not specify Y in the IMS field. System Action: Strobe/ISPF does not process the request. User Response: Specify either CICS or IMS or use the system defaults. Messages Produced by Strobe STR7121E TOGETHER NOT ALLOWED WITH NATURAL. ADABAS AND NATURAL CANNOT BE SELECTED Explanation: You cannot select both the ADABAS and NATURAL data collectors together. System Action: Strobe/ISPF does not process the request. User Response: Specify either ADABAS or NATURAL, or use the system defaults. STR7122E TOGETHER ADABAS/ADA3GL CONFLICT. ADABAS AND ADA3GL CANNOT BE SELECTED Explanation: You cannot select both the ADABAS and the ADA3GL data collectors together. System Action: Strobe/ISPF does not process the request. User Response: Specify either ADABAS or ADA3GL, or use the system defaults. STR7123E 3-181 SEL LIST NOT AVAILABLE. NO ACTIVE JOBS FOUND FOR THE SELECTED LIST TYPE Explanation: On the Strobe - Limit Active Job Lists panel you selected a TYPE for which Strobe/ISPF could find no active jobs. System Action: Strobe/ISPF does not display the active job list. User Response: Select another list type by entering Y to select the desired type on the Strobe - Limit Active Job Lists panel. To view all active jobs, clear the JOBNAME field and press Enter. STR7124E ENTER REQ NUM/JOBNAME. A REQUEST NUMBER OR A JOBNAME IS REQUIRED TO PROCESS THE REQUEST Explanation: You selected an option on the Strobe - Batch-Submission List/Delete Request panel that requires either a request number or jobname, but neither has been specified. System Action: operations. Strobe/ISPF does not produce control statements for the LIST or DELETE User Response: Specify at least one request number or jobname in the REQUEST NUMBER or JOBNAME fields on this panel. STR7128E INVALID DATE. DATE IS EITHER IN INVALID FORMAT, OR IT IS A FUTURE DATE Explanation: You specified an invalid date in the STARTING DATE field. You cannot specify a future date, and you must specify the date in the correct format. System Action: Strobe/ISPF does not process the request. User Response: You cannot specify a future date. Enter the date in the format that the Strobe system programmer specified in the PARMLIB library when installing Strobe. If the Strobe system programmer did not change the specified date format, the default value is dd/mm/yyyy. The value for the day must be from 1 to 31, and the value for the month must be from 1 to 12. STR7129E INVALID USERID. ENTER ALPHANUMERIC CHARACTERS, FIRST CHARACTER MUST NOT BE NUMERIC Explanation: System Action: You specified an invalid user ID in the USERID field. Strobe/ISPF does not allocate the dataset. User Response: Specify a valid user ID consisting of alphanumeric characters or the global search character asterisk (*). The first character must not be numeric. STR7130E UNABLE TO LOCATE LOG. dsname IS PROBABLY DELETED OR UNCATALOGED Explanation: Strobe/ISPF cannot locate the dataset for the Strobe log. The Strobe log is either deleted or uncataloged. System Action: Strobe/ISPF does not allocate the dataset. User Response: Notify the Strobe system programmer. There has probably been an installation error. 3-182 Strobe Messages Guide STR7131E INVALID SUPPRESS OPTION. SUPPRESS CANNOT BE COMBINED WITH OTHER ATTRIBUTION OPTIONS Explanation: You specified Y in both the SUPPRESS field and in one or more of the SUPPRESS REPORTS fields. The SUPPRESS option suppresses all attribution reports, and it cannot be combined with any other attribution options. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Select only the SUPPRESS option to suppress all attribution reports, or you can choose to suppress selected attribution reports. STR7133I NO LOG MESSAGES SELECTED. NO LOG MESSAGES WERE FOUND WHICH MET THE SELECTION CRITERIA Explanation: Strobe/ISPF did not find any messages meeting the selection criteria you specified. You may have specified conflicting or overly restrictive criteria. System Action: Strobe/ISPF does not display messages from the Strobe log. User Response: Adjust the selection criteria or clear all criteria fields to view the entire Strobe log. STR7134E SUPPRESS OR CONDENSE. A CONDENSE PERCENTAGE CANNOT BE SPECIFIED WITH THE SUPPRESS OPTION Explanation: You specified Y in the SUPPRESS field and entered a baseline percentage in the BELOW% field. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: Enter a baseline percentage or select the SUPPRESS option for these reports. STR7135E UNABLE TO OPEN DATA SET. UNABLE TO OPEN dsname Explanation: You specified a function that requires an open dataset. System Action: Strobe/ISPF cannot open the dataset dsname. User Response: Notify the Strobe system programmer. STR7136E UNABLE TO OPEN DATA SET. UNABLE TO OPEN LOG DATA SET Explanation: You attempted to view messages with the .CVM command, with Option L from the Strobe Options menu, or when Strobe returns multiple messages. System Action: messages. Strobe/ISPF cannot open a temporary dataset in which to display the Strobe User Response: Notify the Strobe system programmer. STR7137I NO SSMF MESSAGES. THERE ARE NO SSMF MESSAGES TO DISPLAY Explanation: There are no messages from a component of Strobe, the Strobe session management facility. System Action: Strobe/ISPF does not display SSMF messages. User Response: None required. STR7139E 255 INVALID SVC NUMBER. SVC NUMBER SHOULD BE NUMERIC AND BETWEEN 0 AND Explanation: You specified an invalid SVC number. System Action: Strobe/ISPF does not process the request. User Response: Enter a value between 0 and 255. STR7140E SESSION NUM OUT OF RANGE. NUMBER OF SESSIONS MUST BE A NUMERIC VALUE FROM 1 TO 99 Explanation: You specified an invalid session number in the NUMBER OF SESSIONS field. This number determines how many separate sample datasets Strobe creates during the measurement request. Messages Produced by Strobe System Action: Strobe/ISPF does not process the request. User Response: Specify a value from 1 to 99. STR7141E 3-183 INVALID RANGE. SVC RANGE MUST BE ASCENDING Explanation: You entered a range of SVC numbers that is not in ascending order. System Action: Strobe/ISPF does not process the request. User Response: Enter the range in ascending order, separating the numbers with a hyphen. STR7142E ERRORS REQUEST NOT ADDED. ‘ADD’ REQUEST WAS NOT PROCESSED BY SSMF BECAUSE OF Explanation: A component of Strobe, the Strobe session management facility, detected errors in the Add Active or Add Queued request. System Action: Strobe does not process the request. User Response: Enter the .CVM command to display the error messages for the request. Correct the errors and resubmit the request. STR7143E OPTION CODE NOT VALID. VALID CODES ARE 'V', 'C', 'P', 'G', 'Q', 'X', and 'B' Explanation: You entered an invalid option code. The valid options are: V (view), C (change), P (Profile), G (default Profile), Q (Quit), D (delete request), X (delete request and associated datasets), and B (browse auto Profile). System Action: Strobe/ISPF does not process the option. User Response: Specify a valid option to the left of the appropriate request. STR7144E OPTION NOT ALLOWED. THIS OPTION IS NOT ALLOWED FOR status REQUESTS Explanation: You selected an option that is invalid for a request with the status status. System Action: Strobe/ISPF does not process the option. User Response: Specify a valid option to the left of the appropriate request. STR7145E GRP SUBMIT UNSUCCESSFUL. SUBMIT FAILED FOR ONE OR MORE GROUP ELEMENTS Explanation: One of the request groups that you selected on the Strobe - Request Group Processing panel was not successfully submitted for processing. The line option for this request is highlighted. System Action: Strobe does not add the elements of the group in which it detected errors. User Response: Correct the error(s) and resubmit the group. STR7146E NO SAMPLE DATA SET. MEASUREMENT TASK ERRORS - MESSAGES ARE IN THE STROBE LOG Explanation: You selected a request with no associated sample datasets for Profile (P) or default Profile (G) processing. A sample dataset is necessary to create a Performance Profile. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: To determine why the sample dataset was not allocated, view the measurement task messages for this request in the Strobe log. STR7147E SAMPLE DATA SET IS OPEN. AN OPEN SAMPLE DATA SET CANNOT BE USED TO PRODUCE A PROFILE Explanation: You submitted a request to produce a Strobe Performance Profile from an open sample dataset. The sample dataset must be closed before Strobe can produce a Performance Profile. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: If the request is ACTIVE or SUSPENDED and the sample dataset is open, select Option 3 (STATUS) to send a CHANGE command to close the sample dataset. 3-184 Strobe Messages Guide STR7148I VERIFY CANCEL REQUEST. VERIFY THE CANCEL REQUEST - ‘END’ TO EXIT, ‘ENTER’ TO CONTINUE Explanation: You issued an END command. Strobe/ISPF requires verification before it deletes the generated job stream. System Action: Strobe/ISPF does not delete the job stream. User Response: Press End to complete termination. Strobe/ISPF deletes all the generated job control statements. Press Enter to continue with background processing. STR7149E INVALID COMMAND. THE ABOVE IS AN INVALID SCROLLING COMMAND Explanation: You entered an invalid scrolling command. Valid scrolling commands are a direction (up or down) and an amount (page, half, max, csr, data, or an integer between 0 and 9999) in the SCROLL or OPTION or COMMAND field. System Action: Strobe/ISPF does not scroll for the selected value. User Response: field. Enter a valid command on the OPTION/COMMAND line or in the SCROLL STR7150E INVALID NUM OF SESSIONS. WHEN FINAL SESSION ACTION IS 'C', NUMBER OF SESSIONS MUST BE ONE Explanation: If the final session action is C (continue), you must specify 1 in the NUMBER OF SESSIONS field. System Action: Strobe/ISPF does not process the request. User Response: Specify 1 in the NUMBER OF SESSIONS field or specify Q (quit) or S (stop) as the final session action. STR7151E SELECT 'S' OR 'Q'. FINAL SESSION ACTION OF 'C' CANNOT BE SELECTED WITH CICS Explanation: You specified a final session action of C (Continue) for a measurement session with CICS as a data collector. You cannot specify a final session action of C if the CICS Performance Supplement is to be generated. System Action: Strobe/ISPF does not process the request. User Response: Specify Q (quit) or S (stop) in the FINAL SESSION ACTION field or use the Strobe - Data Collectors panel to suppress CICS. STR7152W NO OPTION INSTALLED. UNABLE TO BUILD OR PROCESS THE INSTALLED OPTIONS TABLE: table Explanation: Strobe/ISPF cannot locate any licensed entries in the options table listed. table identifies the options table being processed: • DCC/ATTR - Data Collectors/Attributors • INDEXER - Source mapping language Indexers • STRITDAX - Internal options table. System Action: Strobe/ISPF attempts to continue processing, but may be severely impacted in what can be processed. • No DCC/ATTR entries means that Strobe processes the measurement request, but will gather no subsystem-specific data. • No INDEXER entries means that this installation does not use any of the languages supported by the INDEXER and that Strobe will not be able to process Source Language Mapping via the INDEXER. • No STRITDAX entries means that Strobe processes the measurement request, but will gather no subsystem-specific data. User Response: Notify the Strobe system programmer and ensure the following: • The load module STRBSLMX is available. • The Options are licensed. • The STRITDAX CSECT is included in the STRBISPF LMOD. Messages Produced by Strobe STR7154I 3-185 REQUEST GENERATED. SELECT ANOTHER OPTION OR ‘7’ TO PROCESS THE REQUEST Explanation: You generated a Batch-Submission Add, Change, or List/Delete request. System Action: Strobe/ISPF saves the control statement generated by the request in a dataset until you submit the job. To submit the job use Option 7 on the Strobe - Batch-Submission Options panel. User Response: Generate more requests and submit the stored control statements using Option 7 or cancel the batch-submission request by pressing End. STR7156I USER DEFAULTS SAVED. USER SPECIFIED OPTIONS HAVE BEEN SAVED Explanation: You changed your user defaults. System Action: Strobe will use the new user default values for subsequent actions. User Response: None required. STR7157E INVALID SPECIFICATION. VALID OPTIONS ARE 'YES' OR 'NO' Explanation: You entered an invalid response. System Action: Strobe/ISPF does not process the request. User Response: Enter YES or NO. STR7158E INVALID SPECIFICATION. VALID SPECIFICATIONS ARE 'T' OR 'I' OR BLANK Explanation: You entered an invalid response. System Action: Strobe/ISPF does not process the Performance Profile request. User Response: default format. Enter T for a Profile report, I for an iStrobe file, or blank for your terminal’s STR7159E LOG ALLOCATION ERROR. FREE FAILED FOR LOG DSN = dsname Explanation: The Strobe log deallocation failed. The temporary dataset remains allocated. System Action: Strobe keeps the dataset allocated, which may cause problems with further allocation requests. User Response: STR7160E FAILED If problems occur, notify the Strobe system programmer. DYNAMIC ALLOCATION ERROR. RC=rc; ERC/IRC=erc/irc; INPUT LOG DEALLOCATION Explanation: The operating system returned a nonzero return code while attempting to deallocate the input browse log dataset. The return code is rc, the error reason code is erc, and the information reason code is irc. System Action: Strobe keeps the dataset allocated, which may cause problems with further allocation requests. User Response: STR7161E Notify the Strobe system programmer. INVALID DATASET. DATASET ORGANIZATION MUST BE PHYSICAL SEQUENTIAL Explanation: The organization of the dataset is incorrect for this function. Strobe will not process a dataset with a dataset organization other than physical sequential. System Action: Strobe does not process the dataset. User Response: Specify a dataset with a dataset organization of physical sequential. STR7162E INVALID LOG DATASET. DATASET RECORD FORMAT MUST BE VBA Explanation: The record format of the dataset is incorrect for this function. Strobe will not process a dataset with a record format other than VBA. System Action: Strobe does not process the dataset. User Response: Specify a dataset with a record format of VBA. 3-186 Strobe Messages Guide STR7163E INVALID LOG DATASET. DATASET RECORD LENGTH MUST BE 137 Explanation: The dataset record length is incorrect. Strobe will not process a dataset with a record length other than 137. System Action: Strobe does not process the dataset. User Response: Specify a dataset with a record length of 137. STR7164E COMMAND NOT VALID. option NOT VALID ON ‘CONFIRM PURGE OF DATASET’ PANEL Explanation: You attempted to execute a Strobe command on the Strobe - Confirm Purge of DataSet panel. You cannot issue Strobe commands from this panel. System Action: Strobe/ISPF does not process the command. User Response: Proceed to the next panel to issue a Strobe command. STR7165E INVALID DATASET. DATASET ORGANIZATION MUST BE PHYSICAL SEQUENTIAL OR PARTITIONED Explanation: The organization of the dataset is incorrect for this function. Strobe will not process a dataset with a dataset organization other than physical sequential or partitioned. System Action: Strobe does not process the dataset. User Response: partitioned. Specify a dataset with a dataset organization of physical sequential or STR7166E BROWSE DATASET ERROR. BROWSE DATASET DEALLOCATION FAILED Explanation: You were browsing a dataset allocated dynamically by Strobe/ISPF. The deallocation of the dataset failed. System Action: Strobe/ISPF may not be able to allocate another dataset of the same type. User Response: If problems occur, notify the Strobe system programmer. STR7167E BROWSE DATASET ERROR. BROWSE DATASET ALLOCATION FAILED Explanation: You attempted to browse a dataset but the dataset allocation failed. System Action: Strobe could not allocate the browse output dataset and could not complete the browse function. User Response: STR7168E Notify the Strobe system programmer. START/END DATE ERROR. START DATE CANNOT BE GREATER THAN END DATE Explanation: You specified a starting date that is later than the ending date. System Action: Strobe/ISPF does not process the request. User Response: Enter dates with a valid range. STR7169E UNABLE TO OPEN DATA SET. UNABLE TO OPEN OUTPUT DATA SET Explanation: You specified a function that requires an open dataset. System Action: Strobe is unable to open the output dataset. User Response: Notify the Strobe system programmer. STR7170E SELECTED INVALID COMBINATION. DATA SET NAMES CANNOT BE BOTH SPECIFIED AND Explanation: You entered a name of a dataset for the Strobe log and also selected a name of a dataset from the list of names. System Action: Strobe/ISPF does not display messages from the Strobe log. User Response: If you select from the list, clear the dataset name field. If you enter the name of a dataset, do not select a name from the list. STR7171E INDICATE LOG DATA SETS. INDICATE LOG DATA SETS OR END TO EXIT Explanation: You pressed Enter without first selecting or entering the name of a dataset for the Strobe log. Messages Produced by Strobe System Action: 3-187 Strobe/ISPF does not display messages from the Strobe log. User Response: To specify a log dataset, either enter the log dataset name or select the name from the list of names and then press Enter. If you do not wish to specify a log dataset, enter END to cancel. STR7173E FUNCTION MEMORY SHORTAGE. STROBE/ISPF COULD NOT GET MEMORY NEEDED FOR Explanation: You specified a function that requires an internal table. System Action: Strobe/ISPF could not build an internal table because sufficient virtual storage was not available. User Response: STR7175E FAILED Allocate more storage or notify the Strobe system programmer. DYNAMIC ALLOCATION ERROR. RC=rc; ERC/IRC=erc/irc; OUTPUT LOG DEALLOCATION Explanation: The operating system returned a non-zero return code while attempting to deallocate the output log dataset. The return code is rc, the error reason code is erc, and the information reason code is irc. System Action: Strobe keeps the dataset allocated, which may cause problems with further allocation requests. User Response: Notify the Strobe system programmer. STR7176E DATA SET NAME REQUIRED. A DATA SET NAME MUST BE SPECIFIED WHEN OPTION 'C' IS SELECTED Explanation: You selected C, the copy option, from the Strobe - Log Utilities panel, but you did not specify a destination dataset name. System Action: Strobe/ISPF does not process the request. User Response: Specify the dataset name to which you will copy. STR7177E INVALID FUNCTION. THE VALID FUNCTIONS ARE 'B', 'P', OR 'C' Explanation: The function you specified is invalid. System Action: Strobe/ISPF does not process the option. User Response: Specify either B (browse), P (print), or C (copy). STR7178E 'KEEP' INVALID DISPOSITION. THE VALID COPY DATA SET DISPOSITIONS ARE 'CATLG' AND Explanation: The disposition that you entered in the DISP field is invalid. The valid dispositions are CATLG or KEEP. System Action: Strobe/ISPF does not allocate the dataset. User Response: Enter either CATLG or KEEP. STR7179E VOLUME NOT SUPPLIED. VOLUME MUST BE SUPPLIED WITH DISPOSITION OF 'KEEP' Explanation: volume. You entered a disposition of KEEP in the DISP field without specifying a System Action: Strobe/ISPF does not allocate the dataset. User Response: Specify a volume or change the disposition to CATLG. STR7180E INVALID SPECIFICATION. VALID OPTIONS ARE 'Y', 'N', OR BLANK Explanation: The selection you entered is invalid. System Action: Strobe/ISPF does not process the option. User Response: Enter either Y or N, or clear the field. STR7181E INVALID NAME. ENTER VALID JOBNAME, USERID, STARTED TASK, OR BLANKS Explanation: System Action: You specified the JOBNAME field incorrectly. Strobe/ISPF does not process the request. 3-188 Strobe Messages Guide User Response: Specify a job name with from one to eight alphanumeric or national characters. The first character must be alphabetic or national. The three national characters are @ # $. STR7182I COPY LOG COMPLETED. LOG EXTRACTS COPIED INTO DATA SET dsname Explanation: dsname. Strobe successfully copied the specified portions of the Strobe log to dataset System Action: Strobe continues processing. User Response: None required. STR7183E PRINT ALLOCATION FAILED. DYNAMIC ALLOCATION ERROR; RC=rc ERC/IRC=erc/irc Explanation: The operating system returned a nonzero return code while attempting to allocate the print file. The return code is rc, the error reason code is erc, and the information reason code is irc. System Action: Strobe/ISPF does not allocate the dataset. User Response: Notify the Strobe system programmer. STR7184E INVALID PRINT CLASS. PRINT CLASS prntclass INVALID; MUST BE ALPHANUMERIC Explanation: through 9). The print class you coded is not alphabetic (A through Z) or numeric (0 System Action: Strobe/ISPF does not print messages from the Strobe log. User Response: Enter a valid print class. STR7185I NO JOBS WITH LIST LIMITS. NO ACTIVE JOBS MATCH LIST LIMITS Explanation: You specified list limits for the active job list. System Action: No active jobs match the active job listing criteria that you specified. User Response: job list. If the jobs you want to measure are excluded, specify broader limits for the STR7186I PRINT LOG COMPLETED. LOG EXTRACT PRINTED TO OUTPUT CLASS outputclass Explanation: You requested Strobe/ISPF to print messages from the Strobe log. System Action: Strobe successfully printed the specified portions of the Strobe log to output class outputclass. User Response: STR7187E You can review the messages in the output class you specified. NO TYPES SELECTED. AT LEAST ONE ACTIVE TYPE MUST BE SELECTED Explanation: System Action: You did not specify a type of address space for the active job list. Strobe/ISPF does not display the active job list. User Response: To select types of address spaces, enter Y next to one or more of the selection types. STR7188E INVALID CHARACTER FOUND. 'A' OR 'D' EXPECTED Explanation: You entered an invalid character for a sort sequence. System Action: Strobe/ISPF does not process the request. User Response: Enter either A for ascending or D for descending. STR7190E AND 999 INVALID RETENTION PERIOD. RETENTION PERIOD MUST BE A NUMBER BETWEEN 0 Explanation: You entered an invalid retention period. System Action: Strobe/ISPF does not process the request. User Response: Enter a value between 0 and 999. Messages Produced by Strobe 3-189 STR7191E INVALID SMS CLASS. YOUR SMS CLASS SPECIFICATION IS SYNTACTICALLY INCORRECT Explanation: System Action: You entered invalid characters in one of the SMS CLASS fields. Strobe/ISPF does not process the request. User Response: Specify a valid Storage Management Subsystem (SMS) class, and resubmit the request. STR7192E INVALID NUMBER. NUMBER SHOULD BE IN THE RANGE 1 - 12 Explanation: You entered an invalid number for display order or sort column. System Action: Strobe/ISPF does not display the active job list. User Response: Enter a number in the range of 1 to 12. STR7193E ALREADY SPECIFIED. THIS VALUE HAS ALREADY BEEN SPECIFIED IN THIS COLUMN Explanation: The value you entered for display order or sort column is a duplicate of a value already entered. System Action: Strobe/ISPF does not display the active job list. User Response: Enter a unique number in the range of 1 to 12. STR7194E INVALID CHARACTERISTICS. MAP DATASET RECORD LENGTH MUST BE 36, FORMAT MUST BE FB Explanation: You specified a partitioned dataset with incorrect map dataset record length or record format. System Action: Strobe/ISPF does not process the Indexer request. User Response: Specify a partitioned dataset with a record length of 36 and a record format of FB or choose a sequential dataset. STR7195E UNIT IS INVALID. VALID UNIT IS 1 TO 8 ALPHANUMERIC, SPECIAL OR NATIONAL CHARACTERS Explanation: System Action: You specified an invalid unit parameter in the UNIT field. Strobe/ISPF does not process the request. User Response: Specify a valid unit parameter. It must be from 1 to 8 alphanumeric, special, or national characters. The three national characters are @ # $. The eleven special characters are blank,. / ) ( ’ * & = +. STR7196E LOG RECORD IS TOO LONG. LENGTH OF LOG RECORD EXCEEDS THE CAPACITY OF THE RESERVED BUFFER Explanation: The message in the Strobe log exceeds the maximum limit of 255 characters. System Action: Strobe/ISPF does not display the message in the Strobe log. User Response: Notify the Strobe system programmer. STR7197E INVALID SORT COLUMN. SORT COLUMN MUST BE IN THE RANGE 1 - 4 Explanation: At the Strobe - Request Group Sort panel, you specified an invalid value in one of the SORT COLUMN fields. Values must be in the range 1 - 4 for general users. System Action: Strobe does not process the request. User Response: Enter only valid values (1 - 4) in the SORT COLUMN fields. STR7198E INVALID DATE SPECIFIED. THE DATE MUST BE GREATER THAN OR EQUAL TO THE CURRENT DATE Explanation: You entered an invalid date in the schedule for a measurement request or a request group. When you create a schedule, the start date and the end date of the schedule must be either the current date or a future date. System Action: Strobe/ISPF does not process the request. User Response: Specify a valid date in the STARTING DATE or the ENDING DATE field on the Strobe - Request Scheduler panel. 3-190 Strobe Messages Guide STR7199E INVALID OPTION. EXPECTED 'A' OR 'E' Explanation: You specified an invalid option while customizing a measurement request or a request group schedule. System Action: Strobe/ISPF does not process the request. User Response: In the OPT field on the Strobe - Request Scheduler panel, specify either A to add a specific date to the schedule, or E to exclude a specific date. STR7200E INVALID SCHEDULE. A REQ OR REQ GROUP CANNOT BE SCHEDULED BEYOND A YEAR FROM TODAY Explanation: You attempted to schedule a measurement request element or a request group for more than one year in the future from today’s date. System Action: Strobe/ISPF does not process the request. User Response: On the Strobe - Request Scheduler panel, ensure that the values in the STARTING DATE and ENDING DATE fields represent a time period of one year or less from today’s date, or specify a value in the NUMBER OF WEEKS field that is one year or less from today’s date. STR7201E NO DAY OF WEEK SELECTED. AT LEAST ONE DAY OF THE WEEK MUST BE SELECTED Explanation: You attempted to schedule a measurement request or a request group but did not specify the days of the week on which you want the measurement session initiated. System Action: Strobe/ISPF does not process the request. User Response: Enter a Y in the field under one or more of the days shown near the top of the Strobe - Request Scheduler panel, or create a customized list by completing the bottom portion of the panel. STR7203E DUPLICATE DATE SPECIFIED. THIS DATE AND TIME HAS ALREADY BEEN GENERATED IN THE WEEKLY LIST Explanation: You attempted to add an individual date to the weekly schedule for a measurement request or a request group. The date you specified, however, is already included in the weekly schedule. System Action: Strobe/ISPF does not process the request. User Response: Ensure that the individual date is not included in the weekly schedule designated in the top section of the Strobe - Request Scheduler panel. STR7204E DATE/TIME DOES NOT EXIST. THIS DATE AND TIME DOES NOT EXIST IN THE GENERATED WEEKLY LIST Explanation: You attempted to exclude an individual date from the weekly schedule for a measurement request or a request group. The date and time you specified, however, does not exist in the weekly schedule. System Action: Strobe/ISPF does not process the request. User Response: Ensure that the individual date is included in the weekly schedule designated in the top section of the Strobe - Request Scheduler panel. STR7205E CANNOT BUILD ADD COMMAND. NEED TO INCREASE REGION MEMORY SIZE ALLOCATED FOR THE PROGRAM Explanation: The ADD command that you are trying to create is too large for the region size that is set. System Action: Strobe/ISPF does not process the request. User Response: Logoff, increase your TSO region size and resubmit the request. STR7206E DUPLICATE START TIME. THIS TIME HAS ALREADY BEEN SPECIFIED. DUPLICATES ARE NOT PERMITTED Explanation: You specified a duplicate starting time for a scheduled measurement request or a request group. System Action: Strobe/ISPF does not process the request. Messages Produced by Strobe 3-191 User Response: Ensure that the times you have specified in the STARTING TIME(s) field of the Strobe - Request Scheduler panel are unique. STR7207E DUPLICATE ENTRY. THIS ENTRY HAS ALREADY BEEN SPECIFIED. DUPLICATES ARE NOT PERMITTED Explanation: You specified an individual date for a measurement request or a request group that is already included in the list of scheduled dates. System Action: Strobe/ISPF does not add the duplicate entry. User Response: Ensure that the dates and times you specified in the list of individual dates at the bottom of the Strobe - Request Scheduler panel are unique. STR7208S TOO MANY ENTRIES. NUMBER OF UNIQUE DATES > STROBE/ISPF LIMIT (12). OPTION UNAVAILABLE Explanation: You are attempting to change the schedule for a request that has more than 12 dates on the bottom of the Strobe - Request Scheduler panel. This will result in a loss of data. System Action: panel. Strobe/ISPF does not allow you to access the Strobe - Request Scheduler User Response: To change the schedule, use the Strobe Command interface. STR7209E INVALID OPTION. VALID ENTRIES ARE 'A' OR BLANK Explanation: You excluded an individual date from the weekly schedule for a measurement request or a request group. However, no weekly schedule is specified. System Action: Strobe/ISPF does not process the request. User Response: Enter an A in the OPT field at the bottom of the Strobe - Request Scheduler panel to add an individual schedule date, or create a weekly schedule. STR7210E INVALID RETRY INTERVAL. RETRY INTERVAL MUST BE IN THE RANGE OF 0 - 60 Explanation: You specified a retry interval for an Add Active measurement request or a request group. However, the value you specified in the RETRY INTERVAL field is invalid. This field represents the time interval, in minutes, that Strobe waits to resubmit the request. System Action: Strobe/ISPF does not process the request. User Response: Enter a value in the range of 0 - 60 in the RETRY INTERVAL field of the Strobe - Request Scheduler panel. STR7211E INVALID TIME SPECIFIED. HOUR RANGE MUST BE 0 - 23 / MINUTE RANGE MUST BE 0 - 59 Explanation: While creating the schedule for a measurement request or a request group, you specified an invalid time either in the weekly schedule or the list of individual dates and times. System Action: Strobe/ISPF does not process the request. User Response: Ensure that the hour and minute values that you entered on the Strobe Request Scheduler panel are valid. STR7212E NUM WEEKS/END DATE ERROR. SPECIFY EITHER THE NUMBER OF WEEKS OR THE END DATE; NOT BOTH Explanation: While creating the schedule for a measurement request or a request group, you specified both the end date and the number of weeks. System Action: Strobe/ISPF does not process the request. User Response: Specify either an ending date or the number of weeks but not both. STR7213E INVALID ENTRY. THIS FIELD MUST BE BLANK IF NO WEEKDAY IS SELECTED Explanation: You specified a value in one of the scheduling fields on the Strobe - Request Scheduler panel, but did not specify a day of the week on which the schedule will run. System Action: Strobe/ISPF does not process the request. User Response: Enter a Y in one or more of the weekday fields shown near the top of the Strobe - Request Scheduler panel. 3-192 Strobe Messages Guide STR7214E START TIME NOT SPECIFIED. AT LEAST ONE START TIME MUST BE SPECIFIED Explanation: You attempted to schedule a measurement request or a request group but did not specify the time at which you want the measurement session initiated. System Action: Strobe/ISPF does not process the request. User Response: Enter at least one time in the STARTING TIME(s) field shown near the top of the Strobe - Request Scheduler panel. STR7215E START DATE NOT SPECIFIED. START DATE MUST BE SPECIFIED Explanation: You specified a day or days of the week on which to schedule a measurement request or a request group but did not specify the date on which you want the schedule to begin. System Action: Strobe/ISPF does not process the request. User Response: Enter a date in the STARTING DATE field shown near the top of the Strobe Request Scheduler panel. STR7216E INVALID DATE FORMAT. MONTH: 1-12 / DAY: DEPENDS ON MONTH / YEAR: UP TO 1 YEAR FROM TODAY Explanation: While creating a schedule for a measurement request or a request group, you specified an unacceptable value in a date field. System Action: Strobe/ISPF does not process the request. User Response: Ensure that the month, day, and year values that you entered are valid. The date must be in the format that the Strobe system programmer specified in the PARMLIB library when installing Strobe. If the Strobe system programmer did not change the specified date format, the default value is dd/mm/yyyy. STR7217E NUM OF WEEKS NOT ENTERED. EITHER THE NUMBER OF WEEKS OR AN END DATE MUST BE SPECIFIED Explanation: You attempted to schedule a measurement request or a request group but did not specify either the number of weeks or the ending date. System Action: Strobe/ISPF does not process the request. User Response: Enter a date in the ENDING DATE field or enter a value in the NUMBER OF WEEKS field that is one year or less from today’s date. STR7218E INVALID NUMBER OF WEEKS. NUMBER OF WEEKS MUST BE IN THE RANGE 1 - 52 Explanation: While creating the schedule for a measurement request or a request group, you specified an invalid number in the NUMBER OF WEEKS fields of the Strobe - Request Scheduler panel. System Action: Strobe/ISPF does not process the request. User Response: today’s date. Enter a value in the NUMBER OF WEEKS field that is one year or less from STR7219E INVALID RETRY ATTEMPTS. RETRY ATTEMPTS MUST BE IN THE RANGE OF 0 - 24 Explanation: You specified an invalid entry in the RETRY ATTEMPTS field. This field represents the number of attempts that Strobe will make to resubmit the request. System Action: Strobe/ISPF does not process the request. User Response: Enter a value in the range of 0 - 24 in the RETRY ATTEMPTS field of the Strobe - Request Scheduler panel. STR7220E INPUT REQUIRED. ENTER DATA ON THE PANEL OR PRESS END TO CANCEL Explanation: You did not specify required data on the panel. System Action: Strobe/ISPF does not process the request. User Response: Enter data or press End to exit the panel. Messages Produced by Strobe STR7221I 3-193 NO SYSTEMS AVAILABLE. NO SYSTEMS CAN BE FOUND IN THE SYSPLEX Explanation: On the Strobe - Add Active or Strobe - Add Queued panel, you attempted to list all the systems in the sysplex by leaving the SYSTEM field blank. Strobe, however, found no systems in the sysplex. System Action: Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. The system programmer can check the Strobe-XCF group to ensure that it is set up correctly. STR7222E SCHEDULE NO SCHEDULE GENERATED. THERE ARE NO DATE AND TIME ENTRIES IN THE Explanation: System Action: You excluded all dates from the weekly schedule. Strobe/ISPF does not process the request. User Response: If you wish to create a schedule for the measurement request or the request group, complete the Strobe - Request Scheduler panel according to the instructions in the Strobe User Guide. STR7223E INVALID SYSTEM NAME. ENTER UP TO 8 ALPHANUMERIC CHARACTERS Explanation: You have entered an invalid system name in the SYSTEM field. System Action: Strobe does not process the request. User Response: Enter up to 8 alphanumeric characters in the SYSTEM field. STR7224E INVALID DAY(S) AND DATES. THE SELECTED DAYS OF THE WEEK ARE NOT IN THE SPECIFIED DATE RANGE Explanation: While creating the schedule for a measurement request or a request group, you selected a weekday that is not within the range specified by the STARTING DATE and ENDING DATE fields on the Strobe - Request Scheduler panel. System Action: Strobe/ISPF does not process the request. User Response: Review your selections and adjust either your weekday selection or the date range specified by the STARTING DATE and ENDING DATE fields. STR7225I GROUP SUBMIT SUCCESSFUL. GROUP SUBMIT(S) SUCCESSFUL Explanation: All the request groups that you selected on the Strobe - Request Group Processing panel have been submitted for processing. System Action: Strobe continues processing. User Response: None required, though to verify that all the request groups were processed, refer to the Strobe log. If the request group was submitted with a schedule, check the Strobe log dataset after the scheduled date and time. STR7226E INVALID STEP NAME. ENTER A VALID STEP OR STEP.PROCSTEP NAME Explanation: You entered an invalid step name in the STEP field on the Strobe - Add Queued Request panel or on the Strobe - Add Queued Request - Multiple Steps panel. System Action: Strobe/ISPF does not accept the value that you entered in this field. User Response: Enter a valid name. STR7227E INVALID STEP NUMBER. ENTER VALID STEP NUMBER (1-255) OR RANGE (XXX-YYY) WHERE YYY > XXX Explanation: You entered an invalid step number on the Strobe - Add Queued Request Multiple Steps panel. System Action: Strobe/ISPF does not process the request. User Response: Enter a valid number or range of numbers. 3-194 Strobe Messages Guide STR7228E INVALID START TIME. START TIME MUST BE AT LEAST 3 MINUTES LATER THAN THE CURRENT TIME Explanation: The start time that you entered is not at least 3 minutes later than the current time. When you are creating a schedule for a measurement request or a request group, the start time of the schedule must be at least 3 minutes later than the current time. System Action: Strobe/ISPF does not process the request. User Response: Specify a valid time in the STARTING TIME field on the Strobe - Request Scheduler panel. STR7229W CON SET ERROR - ENTER HELP. CONCURRENT SET ERROR - NEW OWNER MUST EDIT GROUP groupname Explanation: There is an error in the concurrent set in group groupname, and the owner specified by the group’s owner must edit the group to correct the error. The error can be: there is no trigger request, there is more than one trigger request, or there are no related requests. System Action: Strobe continues processing. User Response: error. The owner specified by the group’s owner must edit the group to correct the STR7230W GROUP WILL BE DELETED. ‘ENTER’ TO DELETE ALL ELEMENTS AND THE GROUP OR ‘END’ TO CANCEL Explanation: On the Strobe - Request Group Elements panel, you specified that one or more request group elements be deleted. Because you are deleting all the elements in the request group, the request group itself will also be deleted. System Action: group. Strobe/ISPF will delete both the request group elements and the request User Response: To delete both the request group elements and the request group, press Enter. Otherwise, press End to exit the panel without making any changes. STR7231I NO GROUPS FOUND. NO GROUPS HAVE BEEN CREATED Explanation: Strobe/ISPF displays this message when you select Option G (REQUEST GROUPS) from the Strobe Options menu or select SAVE REQUEST IN A GROUP from the Strobe - Add Queued Request panel or the Strobe - Add Active Request panel, but you have not yet created any groups. System Action: Strobe continues processing. User Response: Enter the name of a new group to create a group or press End to return to the previous panel. STR7232E INVALID GROUP NAME. CHECK THE SPECIFICATION IN THE GROUP NAME FIELD Explanation: The value that you specified in the GROUP NAME field on the Strobe - Request Group Processing panel or the Strobe - Save Request In Group panel is invalid. System Action: Strobe does not create the request group. User Response: Enter an acceptable value in the GROUP NAME field. Valid entries cannot exceed 18 characters in length and can not include embedded blanks. STR7233E INVALID LINE OPTION. SELECT ONE OF THE LISTED LINE OPTIONS. Explanation: You specified an invalid line option in the OPTION column of the Strobe Request Group Processing panel. Valid options are C (copy), D (delete), E (edit), L (list), U (submit), and T (submit with schedule). System Action: Strobe/ISPF does not process the request. User Response: Specify one of the valid options in the OPTION column. STR7234E DUPLICATE GROUP NAME. THE SPECIFIED GROUP NAME ALREADY EXISTS Explanation: You attempted to create a new request group or save a request in a new group. However, a request group already exists with the name you specified. System Action: Strobe/ISPF does not process the request. Messages Produced by Strobe User Response: 3-195 Choose a unique name for the request group. STR7235E PROCESSING CONFLICT. YOU CANNOT ENTER A NEW GROUP AND USE LINE OPTIONS AT THE SAME TIME Explanation: You attempted to create a new request group or save a request in a new group. However, you also entered one or more of the line options in the OPTION column on the panel. System Action: Strobe/ISPF does not create the request group. User Response: Either enter a group name or enter a line option in the OPTION column, but do not enter both. STR7236E GROUP NOT CREATED. THE SPECIFIED GROUP HAS NOT BEEN CREATED - NO ELEMENTS WERE ADDED Explanation: You attempted to create a new request group on the Strobe - Request Group Processing panel, but you did not create any request group elements for the group. System Action: Strobe/ISPF does not create the request group. Request groups must have at least one request group element to be saved. User Response: Attempt to create the request group again, ensuring that you have created at least one request group element for the group by entering A or Q on the option line of the Strobe - Request Group Elements panel and completing the subsequent panel. If you specify A, the subsequent panel is the Strobe - Create an 'Add Active' Element panel. If you specify Q, the subsequent panel is the Strobe - Create an 'Add Queued' Element panel. STR7237E concurrent CONCURRENT SET ERROR. EXACTLY ONE TRIGGER MUST BE SPECIFIED FOR SET Explanation: You have more than one trigger request in a concurrent set. The concurrent set name is identified by concurrent. System Action: Strobe/ISPF does not allow you to exit the Strobe - Request Group Elements panel without correcting the problem. User Response: concurrent set. STR7238E concurrent Specify only one request group element as the trigger request for the CONCURRENT SET ERROR. AT LEAST ONE NON-TRIGGER MUST BE SPECIFIED FOR SET Explanation: You do not have a non-trigger (related) request in the concurrent set. The concurrent set name is identified by concurrent. System Action: Strobe/ISPF does not allow you to exit the Strobe - Request Group Elements panel without correcting the problem. User Response: concurrent set. Specify at least one request group element as a related request for the STR7239I GROUP [MERGED |DELETED|COPIED|EDITED|CREATED] GROUP(S) [MERGED INTO EXISTING GROUP: groupname| DELETED|COPIED INTO NEW GROUP: groupname|EDITED| CREATED: groupname] Explanation: The group was either merged or copied into groupname, was edited or deleted entirely, or was created with the name groupname, dependent upon your request. System Action: Strobe/ISPF successfully processed the request. User Response: None required. STR7241I ELEMENT ADDED. AN ELEMENT HAS BEEN ADDED TO GROUP: groupname Explanation: You added a request group element to request group groupname from: • the Strobe - Create an 'Add Active' Element panel or • the Strobe - Create an 'Add Queued' Element panel System Action: Strobe/ISPF adds the request group element to the request group and continues processing. User Response: None required. 3-196 Strobe Messages Guide STR7242I ELEMENT EDITED. AN ELEMENT HAS BEEN MODIFIED IN GROUP: groupname Explanation: You edited a request group element in request group groupname from either the Strobe - Edit an 'Add Active' Element panel or the Strobe - Edit an 'Add Queued' Element panel. System Action: Strobe/ISPF modifies the request group element. User Response: None required. STR7243E INVALID LINE OPTION. VALID OPTIONS ARE 'C', 'D', 'E', AND 'V' Explanation: You specified an invalid line option in the OPT column of the Strobe - Request Group Elements panel. Valid options are C (copy), D (delete), E (edit), and V (view). System Action: Strobe/ISPF does not process the selection. User Response: Specify one of the valid line options in the OPT column. STR7244E INVALID LINE OPTION. VALID OPTIONS ARE 'S' AND 'L' Explanation: You specified an invalid line option in the OPTION column of the Strobe - Save Request In a Group panel. Valid options are S (save) and L (list). System Action: Strobe/ISPF does not process the request. User Response: Specify one of the valid line options in the OPTION column. STR7246W SCHEDULE WILL BE REMOVED. THE SCHEDULE WILL BE REMOVED FROM REQUEST BEING SAVED INTO A GROUP Explanation: You specified a Y in the SAVE REQUEST IN GROUP field of the Strobe - Add Active Request or the Strobe - Add Queued Request panel. However, you also specified that this request be submitted with a schedule. System Action: Strobe/ISPF submits the request with the schedule, but removes the schedule from the request before saving it into the request group. The request being saved into the request group will not retain the schedule. User Response: STR7247E SET NAME None required. INVALID CONCURRENT NAME. 'SCHEDULE' CAN NOT BE USED AS THE CONCURRENT Explanation: SCHEDULE, the value that you specified in the CONCURRENT SET NAME field of the Strobe - Concurrent Request panel, is invalid. System Action: Strobe does not create the concurrent set. User Response: Enter an acceptable value in the CONCURRENT SET NAME field. Valid entries cannot exceed 8 characters in length. Note that the word “SCHEDULE” is not a valid name for a concurrent set. STR7248E INVALID CONCURRENT NAME. CHECK THE SPECIFICATION IN THE CONCURRENT SET NAME FIELD Explanation: The value that you specified in the CONCURRENT SET NAME field of the Strobe - Concurrent Request panel is invalid. System Action: Strobe does not create the concurrent set. User Response: Enter an acceptable value in the CONCURRENT SET NAME field. Valid entries cannot exceed 8 characters in length. STR7249E INVALID LINE OPTION. 'V' IS THE ONLY VALID LINE OPTION Explanation: You specified an invalid line option in the OPT column of the Strobe - List Group Elements panel. The only valid line option on this panel is V (view). System Action: Strobe/ISPF does not process the request. User Response: Specify V in the OPT column. Messages Produced by Strobe 3-197 STR7250E GROUP INVALID - ENTER HELP. CONCURRENT SET ERROR. EDIT GROUP groupname OWNER ownerid Explanation: There is an error in a concurrent set within group groupname with owner ownerid. Either there is more than one trigger, there is no trigger, or there are no related (nontrigger) requests. System Action: Strobe/ISPF does not allow you to exit the Strobe - Request Group Processing panel without correcting the problem. User Response: Edit the group identified by groupname and owner ownerid. Specify only one request group element as the trigger request for the concurrent set and specify at least one request group element as a related (non-trigger) request for the concurrent set. STR7251E SYSTEM NAME NOT FOUND. SYSTEM IS NOT A GROUP MEMBER Explanation: The value that you specified on the SYSTEM field is not the name of an existing member of the Strobe-XCF group. Either the system is not included in the installation’s sysplex definition, or the system is defined to the sysplex, but the correct version of Strobe was not started on the system. System Action: Strobe does not process the request. User Response: Enter a valid system name. To find the system names in the sysplex, leave the SYSTEM field blank and press Enter. STR7252E MORE THAN ONE SELECTED. SELECT ONLY ONE SYSTEM Explanation: You selected more than one system on the Strobe - System Selection List panel for an Add Active request. System Action: Strobe does not process the request. User Response: Resubmit the request and specify only one system. STR7253E PANEL S AND E CONFLICT. 'S' AND 'E' ARE MUTUALLY EXCLUSIVE: REMOVE ONE FROM THE Explanation: You cannot choose S (select) and E (exclude) at the same time. System Action: Strobe does not process the request. User Response: Choose either S or E (but not both), or press End to exit the panel. STR7254E NO SELECTION MADE. MAKE A SELECTION OR PRESS END TO EXIT Explanation: You did not select an option from the Strobe - System Selection List panel. System Action: Strobe does not process the request. User Response: Choose an option or press End to exit the panel. STR7255W ONLY 1ST 40 WILL BE KEPT. MORE THAN 40 ENTRIES SELECTED, ONLY FIRST 40 KEPT AS DEFAULT VALUES Explanation: You selected S or excluded E more than 40 entries on the Strobe - System Selection List panel. System Action: Although Strobe displays more than 40 systems, it will save only 40 values. User Response: None required. STR7256E INVALID SYSTEM NAME. ENTER UP TO 8 ALPHANUMERIC CHARACTERS, THE 1ST CANNOT BE NUMERIC Explanation: System Action: The system name that you specified is invalid. Strobe does not process the request. User Response: Enter a valid system name. The system name can be up to 8 alphanumeric or national characters, and the first character cannot be numeric. STR7257E *LIST NOT ACCEPTED. CLEAR THE FIELD & PRESS ENTER TO SELECT A LIST FROM THE NEXT SCREEN Explanation: Strobe was not able to find the list that the *LIST value represented. 3-198 Strobe Messages Guide System Action: Strobe does not process the request. User Response: Clear the SYSTEM field on the Strobe - Add Queued Request panel and press Enter to access the Strobe - System Selection List panel. Indicate the systems on which you want to run the measurement, either by entering S (select), or from which you want to exclude measurement, by entering E (exclude). STR7258E *LIST NOT ACCEPTED. CLEAR PGM & STEP FIELDS, PRESS ENTER TO INPUT A LIST ON NEXT SCREEN Explanation: You specified the value *LIST in the PROGRAM or STEP field of the Strobe Add Queued Request panel. System Action: Strobe/ISPF does not accept the value you entered in this field. User Response: To access the Strobe - Add Queued Request - Multiple Steps panel and specify a list of program names, step names, step numbers, or all steps, clear the PROGRAM and STEP fields and press Enter. STR7259E INVALID SPACE UNIT. DEFAULT WORKSPAC PARAMETER IS INVALID, 'TRACK' SUBSTITUTED Explanation: System Action: You entered an invalid value for the UI_WORKSPAC parameter. Strobe will use the default value of TRACK and process the request. User Response: Contact your Strobe system programmer to enter a valid value for the UI_WORKSPAC parameter in the Strobe PARMLIB member. STR7260I ELEMENT [COPIED|EDITED]. THE ELEMENT HAS BEEN [COPIED|EDITED] Explanation: The element was successfully copied or edited. System Action: Strobe successfully processed the request. User Response: None required. STR7261I ELEMENT CREATED. A NEW ELEMENT HAS BEEN ADDED TO GROUP groupname Explanation: Strobe successfully created an element and added it to the group groupname. System Action: Strobe successfully processed the request. User Response: None required. STR7262W SYSTEM PARAMETER. SYSTEM PARAMETER SPECIFIED IN REQUEST(S) MAY NOT BE SUPPORTED Explanation: For a batch-submission request, you have supplied a SYSTEM parameter. If the system you are sending the request to is not a member of a Strobe sysplex, the system will not recognize the system parameter. System Action: If the system to which you are sending the request does not support multisystem, Strobe will fail with a syntax error. User Response: If the system to which you are sending the request does not support multisystem, go to the JOB STREAM option on the Strobe Options panel, select Option 2 and remove the system parameter from the generated job control statements. STR7263E AUTHORIZATION FAILURE. NOT AUTHORIZED TO EDIT, SUBMIT, OR SAVE A REQUEST IN THIS GROUP Explanation: Users with administrator privileges receive this message when they attempt to edit, submit, or save a request into a group that they did not create. For groups that they did not create, administrators can only copy, list, or delete. System Action: Strobe does not process the request. User Response: You cannot submit, edit, or save requests in a group that you did not create. If you want to submit, edit, or save these requests, you must first copy the group to your user ID. Messages Produced by Strobe 3-199 STR7264E INVALID COMBINATION. WHEN *LIST IS USED IN PROGRAM OR STEP FIELD THE OTHER MUST BE BLANK Explanation: The combination of entries on this panel is invalid. Either you entered *LIST in one field and data in the other field, or the system returned *LIST in one field and you entered data in the other field. System Action: Strobe/ISPF does not process the request. User Response: Clear one of the fields. STR7265E NAME INVALID COMBINATION. A STEP NUMBER CANNOT BE SPECIFIED WITH A PROGRAM Explanation: The combination of entries on this panel is invalid. The PROGRAM field contains a program name and the STEP field contains a step number. System Action: Strobe/ISPF does not process the request. User Response: Clear either the PROGRAM field or the STEP field. You cannot specify both a program name and a step number. STR7266E INVALID COMBINATION. WHEN *ALL IS USED IN THE STEP FIELD THE PROGRAM FIELD MUST BE BLANK Explanation: The combination of entries on this panel is invalid. The PROGRAM field contains a program name and the STEP field contains *ALL. System Action: Strobe/ISPF does not process the measurement request. User Response: Clear the PROGRAM field and enter *ALL in the STEP field. STR7267E INVALID COMBINATION. JOBS CANNOT BE SELECTED IF 'Y' IS ENTERED IN CHANGE LIST OR DISPLAY Explanation: You entered an invalid combination. You cannot enter a Y in either the CHANGE LIST LIMITS field or the CHANGE DISPLAY FORMAT field and also enter an S in the SEL column to select a job name to measure. System Action: Strobe/ISPF does not process the request. User Response: To select one or more job names to measure, clear both the CHANGE LIST LIMITS field and the CHANGE DISPLAY FORMAT field and enter one or more Ss in the SEL column. To limit the active jobs displayed, enter a Y in the CHANGE LIST LIMITS field. To change the information displayed, enter a Y in the CHANGE JOB DISPLAY FORMAT field. You may enter a Y in both the CHANGE LIST LIMITS field and the CHANGE JOB DISPLAY field at the same time, but cannot combine these with one or more Ss in the SEL column. STR7268E INVALID START DATE. THE SCHEDULE START DATE CANNOT BE LATER THAN ONE YEAR FROM TODAY Explanation: You attempted to schedule a measurement request or a request group with a start date that is more than one year from today’s date. System Action: Strobe/ISPF does not process the request. User Response: On the Strobe - Request Scheduler panel, ensure that the STARTING DATE field is one year or less from today’s date. STR7269I X. ELEMENTS DELETED. ELEMENT(S) HAVE BEEN DELETED Explanation: deleted. Strobe has deleted one or more elements. x represents the number of elements System Action: Strobe successfully processed the request. User Response: None required. STR7270E AUTO PROFILE NOT SEL’D. AUTO PROFILE WAS NOT PART OF THIS REQUEST Explanation: You selected B for Browse Auto Profile from the Strobe - Status panel, but you did not specify AUTO PROFILE CREATION for this measurement request. System Action: Strobe/ISPF does not process the request. User Response: To create a Performance Profile, type P to the left of your request. 3-200 Strobe Messages Guide STR7271E SAMPLE FILE NOT CLOSED. AUTO PROFILE REQUIRES CLOSED SAMPLE FILE Explanation: You selected B for Browse Auto Profile from the Strobe - Status panel, but the measurement session has not yet produced a closed sample file from which to automatically create a Performance Profile. System Action: Strobe/ISPF does not process the request. User Response: Select the option later, once Strobe has produced a closed sample file. STR7272E INVALID SAMPLE FILE. SAMPLE FILE HAS INVALID FORMAT Explanation: System Action: The sample file name does not have the required Strobe format. Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. If necessary, contact Compuware Customer Support. STR7273E DATA SET NOT AVAILABLE. AUTO PROFILE DATA SET NOT FOUND. VERIFY THE SUBMITTED JOB Explanation: System Action: Strobe/ISPF is unable to locate the Performance Profile dataset. Strobe/ISPF does not process the request. User Response: Verify that the JCL is correct and that the job has run. Retry Option B Browse Auto Profile. If the problem persists, contact the Strobe system programmer. STR7274E INVALID SORT COLUMN. SORT COLUMN MUST BE IN THE RANGE 1 - 5 Explanation: At the Strobe - Request Group Sort panel, you specified an invalid value in the SORT COLUMN field. Values must be in the range of 1 - 5 for users with administrative authority. System Action: Strobe does not process the request. User Response: Enter only valid values (1 - 5) in the SORT COLUMN fields. STR7275E INVALID SORT SEQUENCE. SORT SEQUENCE MUST BE BLANK IF SORT COLUMN IS NOT SPECIFIED Explanation: At the Strobe - Request Group Sort panel, you specified a value in the SORT SEQUENCE column but did not specify a value in the SORT COLUMN. System Action: Strobe does not process the request. User Response: To specify a value of A (ascending) or D (descending) in the SORT SEQUENCE column, you must specify a value in the corresponding SORT COLUMN field. STR7276I Cannot change profile. Profiles of Batch submitted requests cannot be changed Explanation: Data for the Auto Profile is not available when a request has been submitted via batch. Therefore, it cannot be changed. System Action: Strobe does not process the request. User Response: The batch file must be re-created with the new Auto Profile parameters. Then the batch must be submitted again for a new request. STR7277E is selected. Invalid Option. (B)ackground processing is the only valid option if iStrobe File output Explanation: Requesting a Strobe Profile Report in the iStrobe output format is only supported by Background (batch job) processing. System Action: Strobe does not process the request. User Response: To request a Strobe Profile Report in the iStrobe output format, you must specify B (Background) processing. STR7278E INVALID OWNERID. ENTER VALID OWNERID, PATTERN, OR BLANKS Explanation: System Action: You specified an invalid owner ID in the OWNERID field. Strobe/ISPF does not process the request. Messages Produced by Strobe 3-201 User Response: Enter a valid owner ID in the OWNERID field. To view multiple owner IDs, enter a pattern or blanks. STR7280E INVALID SYSTEM NAME. *ALL OR *LIST IS INVALID FOR ACTIVE REQUESTS/ACTIVE GROUP ELEMENTS Explanation: You specified *ALL or *LIST in the SYSTEM field for an ADD ACTIVE request or an ACTIVE GROUP ELEMENT. For an ADD ACTIVE request or an ACTIVE GROUP ELEMENT you must specify a system name in the SYSTEM field or leave the field blank. System Action: Strobe does not process the request. User Response: Specify the name of a system or leave the field blank and press Enter. If you leave the field blank, select only one of the systems from the list that appears on the subsequent Strobe - System Selection List panel. STR7281E CANNOT SCHEDULE. CANNOT SCHEDULE FROM 23:57 TO 23:59 WITH START DATE = CURRENT DATE Explanation: For internal processing, Strobe requires a three-minute margin between the time you submit a measurement request and the time at which the measurement request is scheduled to execute. Because of this constraint, Strobe cannot process a request submitted during the last three minutes of the day (from 23:57 to 23:59) that is scheduled to execute before the end of the same day (either on or before 23:59). System Action: Strobe does not process the request. User Response: To schedule a request to execute during the last three minutes of the day (from 23:57 to 23:59) submit the request earlier than three minutes before the end of the day (earlier than 23:57). This only applies to requests that are scheduled to execute on the same day that they are submitted. STR7282E INVALID SPECIFICATION. ENTER 'A' FOR AM OR 'P' FOR PM Explanation: A and P are the only characters that are valid for this field, and you entered a character that is not an A or a P. System Action: Strobe does not process the request. User Response: Enter A for A.M. or P for P.M. STR7283E INVALID TIME SPECIFIED. HOUR MUST BE 1 - 12 | MINUTE MUST BE 0 - 59| AM/PM MUST BE A OR P Explanation: The time that you specified is invalid. In the hour field you must enter a number from 1 to 12. In the minute field you must enter a number from 0 to 59. In the AM/PM field you must enter either A (for A.M.) or P (for P.M.). System Action: Strobe does not process the request. User Response: Because you have chosen the AM/PM format, you must enter a number from 1 to 12 in the hour field. Enter a number from 0 to 59 in the minute field. Enter A (for A.M.) or P (for P.M.) in the AM/PM field. STR7284E INVALID SPECIFICATION. IMS DC MUST BE SET TO 'Y' FOR THE IMS CAPTURE OPTION TO BE USED Explanation: You requested an IMS processing option without selecting the IMS data collector on the Strobe - Data Collectors panel. System Action: invoked. Strobe cannot process any IMS options until the IMS data collector is User Response: Specify Y next to the IMS data collector on the Strobe - Data Collectors panel. STR7285E INVALID SPECIFICATION. DB2 DC MUST BE SET TO 'Y' FOR THE DB2 CAPTURE OPTION TO BE USED Explanation: You requested a DB2 processing option without selecting the DB2 data collector on the Strobe - Data Collectors panel. System Action: invoked. Strobe cannot process any DB2 options until the DB2 data collector is 3-202 Strobe Messages Guide User Response: panel. Specify Y next to the DB2 data collector on the Strobe - Data Collectors STR7286E PROCESSING CONFLICT. YOU CANNOT CHANGE THE OWNER MASK AND USE LINE OPTIONS AT THE SAME TIME Explanation: You attempted to change the owner mask, and you entered one or more of the line options in the OPTION column on the panel. System Action: Strobe does not process the request. User Response: Either change the owner mask or enter a line option in the OPTION column, but do not attempt to do both. STR7287E PROCESSING CONFLICT. YOU CANNOT CHANGE SORT CRITERIA AND USE LINE OPTIONS AT THE SAME TIME Explanation: You attempted to change the criteria used for sorting, and you entered one or more of the line options in the OPTION column on the panel. System Action: Strobe does not process the request. User Response: Either change the sort criteria or enter a line option in the OPTION column, but do not attempt to do both. STR7288E INVALID TRANSACTION. ENTER A VALID TRANSACTION. A WILDCARD IS PERMITTED Explanation: You entered a transaction that is syntactically incorrect. The transaction name must consist of from 1–8 of the following alphanumeric or national characters: A–Z, #, $, @, 0– 9. The first character may not be numeric, but it may be a period. The last character may be an asterisk (*), which acts as a wildcard. System Action: Strobe will not process the request. User Response: paragraph. Enter a transaction name that follows the rules given in the Explanation STR7289E INVALID DBRM. ENTER A VALID DBRM. A WILDCARD IS PERMITTED Explanation: You entered a DBRM name that is syntactically incorrect. The DBRM name must consist of from 1–8 of the following alphanumeric or national characters: A–Z, #, $, @, 0– 9. The first character may not be numeric. The last character may be an asterisk (*), which acts as a wildcard. System Action: Strobe will not process the request. User Response: paragraph. Enter a DBRM name that follows the rules given in the Explanation STR7290E INVALID STEP NAME. ENTER VALID STEP OR STEP.PROCSTEP. A WILDCARD IS PERMITTED Explanation: You entered a step or step.procstep name that is syntactically incorrect. The step name must consist of from 1–8 of the following alphanumeric or national characters: A–Z, #, $, @, 0–9. The first character may not be numeric. The last character may be an asterisk, which acts as a wildcard. A single asterisk in the field is valid and it also acts as a wildcard. System Action: Strobe will not process the request. User Response: Enter a step or step.procstep name that follows the rules given in the Explanation paragraph. STR7291E INVALID HISTORIAN. ENTER A VALID HISTORIAN. A WILDCARD IS PERMITTED Explanation: You entered a historian name that is syntactically incorrect. The historian name must consist of from 1–8 of the following alphanumeric or national characters: A–Z, #, $, @, 0–9. The first character may not be numeric. The last character may be an asterisk, which acts as a wildcard. System Action: Strobe will not process the request. User Response: Enter a historian name that follows the rules given in Explanation. Messages Produced by Strobe STR7292E 3-203 REQUIRED FIELD. SORT ORDER AND SEQUENCE FIELDS MUST BE ENTERED IN PAIRS Explanation: You did not enter a sort order or sort sequence in pairs. When you specify a sort order for one of the display titles, you must also specify a sequence for the sort—either A (ascending) or D (descending). Also, if you specify a sequence for a display title, you must indicate the order in which to sort it. System Action: Strobe does not process the request. User Response: For each value that you select in the DISPLAY TITLE column, you must enter both a sort order and a sort sequence. STR7293E RANGE INVALID SORT ORDER. SORT ORDER FIELD IS EITHER NOT NUMERIC OR OUT OF Explanation: One or more of the values that you specified for sort order is invalid. The sort order must be a numeric value in the range specified on the panel. System Action: Strobe does not process the request. User Response: Enter a valid sort order. STR7294E INVALID FUNCTION. VALID OPTIONS ARE 'P' AND 'E' Explanation: The only valid options are P to print the history data or E to export the history data. System Action: Strobe does not process the request. User Response: Enter either P to print or E to export the history data. STR7296E INVALID PRINT CLASS. THE PRINT CLASS MUST BE ALPHANUMERIC Explanation: You entered a print class that is not alphanumeric (A–Z or 0–9). System Action: Strobe does not process the request. User Response: Enter a print class that adheres to the rules defined in the Explanation. STR7297E ONE PRINT VALUE REQUIRED. ENTER EITHER A PRINT DATA SET NAME OR A SYSOUT CLASS, NOT BOTH Explanation: You entered both a dataset name and a sysout class on the PRINT OPTIONS section of the Strobe - History - Print/Export panel. You cannot choose both. System Action: Strobe does not process the request. User Response: To print to a dataset, enter only a dataset name. To print to a sysout class, enter only a sysout class. STR7298E INVALID FREQUENCY. THE ANNUAL FREQUENCY VALUE MUST BE IN THE RANGE OF (0 - 9999), (0 - 99999999) Explanation: You entered an annual frequency value that is not in the range of (0–9999) for step views or (0–99999999) for DBRM or transaction views. System Action: Strobe does not process the request. User Response: Enter a numeric value for annual frequency within the required range. STR7299E HISTORY DISABLED. THE STROBE HISTORY FUNCTION IS DISABLED Explanation: data. System Action: The Strobe history manager is not functioning. Strobe will not display history Strobe continues processing but does not process history related requests. User Response: An ABEND or an error has occurred either during Strobe installation or while accessing history data. Contact the Strobe system programmer to ensure that the correct parameters were specified during Strobe installation. If the problem persists, contact Compuware Customer Support. STR7300E NO RECORDS FOUND. NO HISTORY RECORDS WERE FOUND FOR THE SPECIFIED FILTER CRITERIA Explanation: There are no measurement session history records that match the filter criteria that you specified. 3-204 Strobe Messages Guide System Action: Strobe does not process the request. User Response: Enter different filter criteria. STR7301E BOTH COMMAND CONFLICT. ENTER EITHER A PANEL COMMAND OR LINE OPTIONS, NOT Explanation: You entered both a panel command and one or more line options. You cannot enter both panel commands and line options at the same time. System Action: Strobe does not process the requests. User Response: Enter either a panel command or one or more line options. STR7302E INVALID LINE OPTION. VALID LINE OPTIONS ARE 'S' AND 'D' Explanation: You entered a line option other than S or D. On this panel, the only valid line options are S to select a record or D to delete a record. System Action: Strobe does not process the request. User Response: Enter either S or D as line options, or any of the available panel commands, which are defined on the panel. STR7303E INVALID LINE OPTION. THE ONLY VALID LINE OPTION IS 'S' Explanation: You entered a line option other than S. On this panel, the only valid line option is S to select a record. System Action: Strobe does not process the request. User Response: the panel. Enter an S line option or any of the panel commands, which are defined on STR7304E FOUND INVALID COMMAND. PRINT/EXPORT IS DISABLED WHEN NO HISTORY DATA IS Explanation: You entered the PE panel command to print or export measurement session history records, but no measurement session history records are present. System Action: Strobe does not process the request. User Response: Because Strobe found no measurement session history records for the filter criteria that you specified, no measurement session history records were available to print or export. The Print/Export command is not valid when no measurement session history records are present. STR7305E INVALID LINE OPTION. VALID LINE OPTIONS ARE 'D', 'P', 'U', 'V', 'B', AND 'O' Explanation: You entered an invalid line option. The only valid line options are: D (delete), P (profile), U (update measurement session history record), V (view more details), B (baseline), and O (compare to baseline). System Action: Strobe does not process the request. User Response: Enter a valid line option or any of the available panel commands, which are defined on the panel. STR7306E HISTORY ERROR errortext Explanation: errortext. The history manager has encountered an error. The error is described in System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7307E ONE RECORD AS BASELINE. ONLY ONE RECORD MAY BE SELECTED AS THE BASELINE Explanation: You entered a B line option, indicating select as a baseline, for more than one measurement session history record. Only one measurement session history record may be designated as the baseline against which other measurement session history records will be compared. System Action: Strobe does not process the request. User Response: Designate only one measurement session history record as a baseline. Messages Produced by Strobe STR7308E 3-205 BASELINE REQUIRED. A BASELINE IS REQUIRED IF COMPARE RECORDS ARE SELECTED Explanation: For one or more measurement session history records, you entered an O line option, indicating that the measurement session history record is to be compared to the baseline measurement session history record, but you did not select a baseline measurement session history record. If you select one or more comparison measurement session history records, you must select a baseline measurement session history record. System Action: Strobe does not process the request. User Response: option B. Select a baseline measurement session history record by entering line  STR7309E COMPARE RECORD REQUIRED. 1 OR MORE COMPARE RECORDS REQUIRED IF A BASELINE IS SELECTED Explanation: You entered a B line option, indicating that the measurement session history record is a baseline measurement session history record, but you did not select measurement session history records to be compared to the baseline. System Action: Strobe does not process the request. User Response: Select one or more comparison records by entering an O line option. STR7310E INVALID EXCP COUNT. EXCP COUNT THRESHOLD MUST BE A NUMBER FROM 0 TO 2147483647 Explanation: The value you entered for the EXCP count threshold is not valid. Valid values are within the range of 0 to 2147483647. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7311E INVALID VALUE. CPU TIME HAS A MAXIMUM OF 1440 MINUTES Explanation: The value you entered as the CPU time minutes threshold is not valid. Valid values are within the range of 0 to 1440. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7312E INVALID VALUE. THRESHOLD SECONDS MUST BE A NUMBER FROM 0 TO 59.00 Explanation: The value you entered as the seconds threshold is not valid. Valid values are within the range of 0 to 59.00. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7313E 99.99 INVALID PERCENTAGE. THRESHOLD PERCENTAGE MUST BE A NUMBER FROM 0 TO Explanation: The value you entered as the percentage threshold is not valid. Valid values are percentages within the range of 0 to 99.99. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7314E VALID LINE OPTION IS 'U'. THE ONLY VALID LINE OPTION IS 'U' FOR UPDATE Explanation: The only valid line option is U, which enables you to update the measurement session history record. System Action: Strobe will not process the request. User Response: Enter U to update the measurement session history record, or enter any of the available panel commands, which are defined on the panel. STR7315E COMMAND FAILED. THE COMMAND REQUESTED DID NOT COMPLETE SUCCESSFULLY Explanation: The command you issued failed. 3-206 Strobe Messages Guide System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7316E NO COST RECORD FOUND. DEFAULT COST RECORD HAS NOT BEEN DEFINED Explanation: A default cost record was not defined at installation. System Action: Strobe will not process cost data. User Response: Notify the Strobe system programmer. STR7317E INVALID COMMENT. UNDERSCORE OR DOUBLE QUOTES ARE INVALID IN COMMENT TEXT Explanation: You entered an underscore (_) or double quotes (") in the comment field. Underscores or double quotes are not allowed in this field. System Action: Strobe will not update the record. User Response: quotes ("). Enter text in the comment field without using an underscore (_) or double STR7318E INVALID COST RECORD DATA. COST CATEGORY MUST BE 0, 1, OR 2 Explanation: The history dataset has become corrupted. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7319I commandname SUCCESSFUL. commandname COMPLETED SUCCESSFULLY Explanation: The command you issued, commandname, completed successfully. System Action: None. User Response: None required. STR7320E INTERNAL ERROR. INVALID RECORD TYPE PASSED TO modname Explanation: An invalid record type was passed to module modname. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7321E INVALID COST CATEGORY. COST CATEGORY MUST BE 'PR', 'NP', OR BLANK Explanation: You entered a cost category other than PR for prime cost, NP for non-prime cost, or blank. System Action: Strobe does not process the request. User Response: Enter a cost category of PR for prime, NP for non-prime, or blank. If you leave the field blank, the system will determine the cost based on the time of measurement and the cost record associated with the system on the measurement session history record. STR7322E COMMAND NOT ALLOWED. THE HISTORY CANNOT BE CHANGED WITHOUT A DEFAULT COST RECORD Explanation: A default cost record was not defined at installation. You cannot update the measurement session history record without first defining a default cost record. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer to define a default cost record. STR7323E COMPARE FAILED. errortext Explanation: The comparison routine failed. errortext describes the error. System Action: Strobe does not display the history comparison information. User Response: Notify the Strobe system programmer. Messages Produced by Strobe 3-207 STR7324E NO COST DATA. COST DATA IS NOT AVAILABLE. THE COST COMPARISON COMMAND IS REJECTED Explanation: The cost comparison function cannot complete because cost information is not available on your system. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7325E RECORD NOT FOUND. THE HISTORY RECORD NEEDED FOR THE FUNCTION REQUESTED WAS NOT FOUND Explanation: The history dataset has become corrupted. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7326E COMMAND CONFLICT. CANNOT ADD A COST RECORD AND USE LINE OPTIONS AT THE SAME TIME Explanation: You entered Y in the Add Cost Record field and also entered one or more line options for the cost records. You cannot add a cost record and use line options at the same time. System Action: Strobe does not process the request. User Response: To add a cost record, enter Y in the Add Cost Record field. Do not use line options at the same time as adding a cost record. STR7327E COST RECORD DELETED. COST RECORD SUCCESSFULLY DELETED Explanation: The deletion of a cost record from the history database was successful. System Action: None. User Response: None required. STR7328E INVALID LINE OPTION. VALID LINE OPTIONS ARE 'U' AND 'D' Explanation: You entered a line option other than U to update a record or D to delete a record. The only valid line options are U or D. System Action: Strobe does not process the request. User Response: Enter either U to update a record or D to delete a record. STR7329E CANNOT DELETE DEFAULT. THE DEFAULT PRIME AND NON-PRIME COST RECORDS CANNOT BE DELETED Explanation: You cannot delete the default prime and non-prime cost records. System Action: Strobe does not process the request. User Response: None required. STR7330E NO CHANGES MADE. UPDATE WAS SELECTED BUT NO CHANGES WERE MADE Explanation: You entered the U line option to update a cost record, but entered no changes on the Strobe - History - Machine Cost Edit panel. System Action: Strobe does not process the request. User Response: To update a record, enter your changes on this panel and press Enter, or press End to cancel. STR7331E INVALID CPU MODEL. INVALID CPU MODEL - NO EMBEDDED BLANKS AND CANNOT BE A SINGLE '*' Explanation: System Action: The CPU model that you specified is not syntactically correct. Strobe does not process the request. User Response: Enter a CPU model that is syntactically correct. It cannot have embedded blanks and it cannot be a single asterisk (*). If you use an asterisk, however, it will not act as a wildcard. 3-208 Strobe Messages Guide STR7332E INVALID RECORD TYPE. ENTER 'S' FOR A SYSTEM RECORD OR 'U' FOR A USER RECORD Explanation: You either left the RECORD TYPE field blank or entered a record type other than S for SYSTEM or U for USER. A system record is used globally by all users while a user record is used only by the record creator. System Action: Strobe does not process the request. User Response: Enter either S to indicate a SYSTEM record or U to indicate a USER record. STR7333E RECORD ALREADY EXISTS. THIS COST RECORD ALREADY EXISTS Explanation: System Action: This cost record already exists. Strobe does not process the request. User Response: To add a new cost record from this panel, change the system definition information and press Enter. To update the cost record from this panel, press PF3 to exit the panel and then enter the U line option. STR7334I RECORD ADDED. THE COST RECORD WAS SUCCESSFULLY ADDED Explanation: The addition of the cost record to the history database was successful. System Action: None. User Response: None required. STR7336E RECORD UPDATED. THE COST RECORD WAS SUCCESSFULLY UPDATED Explanation: The cost record you selected has been updated. System Action: None. User Response: None required. STR7337E INVALID COST INPUT. ENTER CPU AND I/O COST -OR- SERVICE UNIT COST Explanation: You must specify the same category of cost for both prime and non-prime rates. For example, if you specify CPU hour and I/O costs for Prime cost then you must specify CPU hour and I/O costs for non-prime cost. Similarly, if you specify service units for Prime cost, you must also specify service units for non-prime costs. System Action: Strobe does not process the request. User Response: Specify the same category of cost for both prime cost and non-prime cost. STR7338E INVALID COST INPUT. ENTER CPU AND I/O COST -NOT- SERVICE UNIT COST Explanation: Because you specified CPU and I/O cost for prime cost, you must also specify CPU and I/O cost for non-prime cost. System Action: Strobe does not process the request. User Response: Enter the same category of costs for both prime and non-prime costs: either CPU and I/O cost or service units cost. STR7339E INVALID COST INPUT. ENTER SERVICE UNIT COST -NOT- CPU AND I/O COST Explanation: Because you specified service units for prime cost, you must also specify service units for non-prime cost. System Action: Strobe does not process the request. User Response: Enter the same category of costs for both prime and non-prime costs: either CPU and I/O cost or service units cost. STR7340E INVALID CPU HOUR COST. MUST BE A NUMERIC VALUE FROM 0 TO 99999.99 Explanation: You entered an invalid value for the CPU hour cost. The greatest value you can enter is 99999.99 specified in that format. The maximum number of digits to the left of the decimal point is five and the maximum number of digits to the right of the decimal point is two. System Action: Strobe does not process the request. User Response: Enter a value that adheres to the rules in the Explanation. Messages Produced by Strobe STR7341E 3-209 INVALID I/O COST. MUST BE A NUMERIC VALUE FROM 0 TO 999999.999 Explanation: You entered an invalid value for the I/O cost. The greatest value you can enter is 999999.999 specified in that format. The maximum number of digits to the left of the decimal point is six and the maximum number of digits to the right of the decimal point is three. System Action: Strobe does not process the request. User Response: Enter a value that adheres to the rules in the Explanation. STR7342E INVALID SERVICE UNIT CST. MUST BE A NUMERIC VALUE FROM 0 TO 99999.999 Explanation: You entered an invalid value for the service unit cost. The greatest value you can enter is 99999.999 specified in that format. The maximum number of digits to the left of the decimal point is five and the maximum number of digits to the right of the decimal point is three. System Action: Strobe does not process the request. User Response: Enter a value that adheres to the rules in the Explanation. STR7343E INVALID COST RECORD DATA. COST CATEGORY INDICATOR MUST BE 'D', 'S', OR 'U' Explanation: The history dataset has become corrupted. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7344E INVALID COST RECORD DATA. COST CATEGORY MUST BE 'NP', OR 'PR' Explanation: cost. You entered a cost category other than PR for prime cost or NP for non-prime System Action: Strobe does not process the request. User Response: Enter either PR for prime cost or NP for non-prime cost. STR7345E COST TABLE FULL. THERE ARE MORE THAN 100 SYSTEM/CPU PAIRS DEFINED Explanation: You attempted to add a cost record, however, the maximum number of system/CPU pairs, which is 100, has already been defined. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7346E LINE COMMAND NOT ALLOWED. LINE COMMANDS ARE NOT ALLOWED WHEN THE FREQUENCY IS CHANGED Explanation: You entered a line command while you were changing the annual frequency on one of the Measurement Session History panels of AutoStrobe. System Action: Strobe/ISPF does not process the request. User Response: Change the annual frequency and press Enter. After the panel is refreshed, enter a line command to view the history details. The selections cannot be combined. STR7347I FREQUENCY UPDATED. THE FREQUENCY HAS BEEN CHANGED TO frequency Explanation: The annual frequency is now frequency. System Action: None. User Response: None required. STR7348E INVALID RANGE. TOP N WAIT USERS FIELD HAS LIMIT OF 20 Explanation: 20. You entered a value for the top number of wait users that exceeds the limit of System Action: Strobe does not process the request. User Response: Enter a value of 20 or less for the top wait users. 3-210 Strobe Messages Guide STR7349 INVALID COMBINATION. CANNOT ENTER BOTH TOTAL WAIT PERCENT AND TOP N WAIT USERS Explanation: You entered values for total wait time percent and the top number of wait users. You cannot choose values for both. System Action: Strobe does not process the request. User Response: Enter a value that defines the percent of total wait time or the top number of wait time users, not both. STR7350E INVALID COMBINATION. CANNOT ENTER BOTH TOTAL CPU PERCENT AND TOP N CPU USERS Explanation: You entered values for total CPU consumption percent and the top number of CPU users. You cannot choose values for both. System Action: Strobe does not process the request. User Response: Enter a value that defines the percent of total CPU or the top number of wait time users, not both. STR7351E INVALID ENTRY. ENTER ALPHANUMERIC OR NATIONAL CHARACTERS - 1ST MUST NOT BE NUMERIC Explanation: You entered a value that is syntactically incorrect. Enter a value that consists of the following alphanumeric or national characters: A–Z, #, $, @, 0–9. The first character may not be numeric, but it may be a period. System Action: Strobe does not process the request. User Response: Enter a value that adheres to the rules in the Explanation. STR7352E SELECT A REPORT TYPE. AT LEAST ONE REPORT TYPE MUST BE SELECTED Explanation: You indicated that you wanted to see SQL analysis reports, but you failed to select one or more of the available options for the type of report. System Action: Strobe does not process the request. User Response: Enter one or more of the following options for the types of SQL analysis reports you want to see: EXPLAIN, TRANSLATION, OPPORTUNITIES, and STATISTICS. STR7354I RECORD NOT UPDATED. THE UPDATE WAS NOT CONFIRMED SO THE COST RECORD WAS NOT UPDATED Explanation: request. System Action: Strobe did not update the cost record because you did not confirm the update Strobe does not update the cost record. User Response: None required. To update the cost record, reenter the update request and press Enter to confirm the update. STR7355E BASELINE OUT OF RANGE. DBRM AND TRAN BASELINES MUST BE A VALUE BETWEEN 0.0 AND 99.999 Explanation: The value that you entered in the DBRM baseline or TRAN (transaction) baseline field is invalid. Valid values are between 0.0 and 99.999. System Action: Strobe does not process the request. User Response: Enter a valid value or leave blank to accept the default baseline. See the Strobe User Guide for default values. STR7356E INVALID VALUE. TOTAL SAMPLES PROCESSED HAS A MAXIMUM OF 150000 Explanation: The value that you entered as the total samples processed threshold is not valid. Valid values are within the range of 0 to 150000. System Action: Strobe does not process the request. User Response: Enter a valid value. Messages Produced by Strobe STR7357E 3-211 INVALID VALUE. SESSION TIME HAS A MAXIMUM OF 1440 MINUTES Explanation: The value that you entered as the session time minutes threshold is not valid. Valid values are within the range of 0 to 1440 minutes. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7358E INVALID VALUE. WAIT TIME HAS A MAXIMUM OF 1440 MINUTES Explanation: The value that you entered as the wait time minutes threshold is not valid. Valid values are within the range of 0 to 1440. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7359E INVALID VALUE. STRETCH TIME HAS A MAXIMUM OF 1440 MINUTES Explanation: The value that you entered as the stretch time minutes threshold is not valid. Valid values are within the range of 0 to 1440. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7360E NOT AUTH’D TO DELETE SDS. YOU ARE NOT AUTHORIZED TO DELETE A SAMPLE DATASET. USE “D” INSTEAD Explanation: this request. System Action: You do not have the authority to delete the sample datasets associated with Strobe/ISPF does not process the request. User Response: Select D to delete request without deleting datasets, or notify the Strobe system programmer. STR7361E INVALID NUMBER. NUMBER SHOULD BE IN THE RANGE OF 1-13 Explanation: You entered an invalid number for the display order. System Action: Strobe/ISPF does not display the active process list. User Response: Enter a number in the range of 1 to 13. STR7362E INVALID SPECFICATION. VALID OPTIONS ARE “J” OR “P” Explanation: You entered an invalid value in the JOBNAME field on the Strobe - Add Active Request panel. System Action: Strobe/ISPF does not process request. User Response: Enter J to display active jobs or P to display active processes. STR7363E INVALID SPECIFICATION. MQSERIES DC MUST BE SPECIFIED AS Y FOR MQSERIES OPTIONS TO BE USED Explanation: You requested a Strobe for WebSphere MQ processing option without specifying Y in the MQSeries data collector field on the Strobe - Data Collectors panel. System Action: Strobe/ISPF cannot process MQSeries options unless you specify Y in the MQSeries data collector field. User Response: panel. Specify Y next to the MQSeries data collector on the Strobe - Data Collectors STR7364E CICS OPTIONS ERROR. PERFORMANCE SUPPLEMENT & REGION DATA/TRANS CANNOT BOTH BE SELECTED Explanation: You entered a Y in both the Produce Performance Supplement/Collect Terminal Activity fields and in the Collect Region Data/Detail Transactions fields on the Strobe - CICS Data Collector Options panel. System Action: Strobe/ISPF does not process the request. 3-212 Strobe Messages Guide User Response: You cannot enter Y for both options. Select either the option for Produce Performance Supplement/Collect Terminal Activity or the option for Collect Region Data/Detail Transactions on the Strobe - CICS Data Collector Options panel. STR7365E INVALID COMBINATION. ENTER 1 OR MORE TRANSACTIONS OR SPECIFY WHICH REPORT TO PROCESS Explanation: You entered an N in either the Collect Region Data field or the Produce Performance Supplement field on the Strobe - CICS Data Collector Options panel, but left the other fields blank. System Action: Strobe/ISPF does not process the request. User Response: them. Enter transactions or enter Y to produce these reports. Enter N to suppress STR7366E INVALID TRANSACTION NAME. ENTER UP TO 4 ALPHANUMERIC/NATIONAL/ SPECIAL CHAR--WILDCARD PERMITTED Explanation: You entered an incorrect character in the transaction field. System Action: Strobe/ISPF does not process the request. User Response: characters: Enter up to four of any of the following alphanumeric, national, or special A–Z a–z 0–9 $ @ # . / % & ? ! : “ ^ < > ¢ STR7367E PARAMETER OUT OF RANGE. VALUE MUST BE BETWEEN 0.000 AND 99.999 SECONDS Explanation: You entered an invalid value for either the CICS Transaction Profile compress below % field or for the CICS Region Level compress below % field. System Action: Strobe/ISPF does not process the request. User Response: Enter a value between 0.000 and 99.999. STR7368E INVALID COMBINATION. CANNOT SUPPRESS ALL REPTS OR SPECIFY CICS TRANS & SPECIFY FILTERS Explanation: You cannot suppress both the CICS Transaction Profile reports and the nonCICS Transaction Profile reports. You also cannot specify CICS transactions and suppress CICS Transaction Profile reports. System Action: Strobe/ISPF does not process the request. User Response: Either suppress the CICS Transaction Profile reports or suppress the non-CICS Transaction Profile reports. STR7369E DISPLAY INVALID COMBINATION. JOBS CANNOT BE SELECTED IF Y IS ENTERED IN CHANGE Explanation: You entered an invalid combination. You cannot enter a Y in the CHANGE DISPLAY FORMAT field and an S in the SEL column on the Strobe - Active Process Selection List panel to select a process to measure. System Action: Strobe/ISPF does not process the request. User Response: To select one or more processes to measure, clear the CHANGE DISPLAY FORMAT field and enter one or more Ss in the SEL column. To change the displayed information, enter a Y in the CHANGE DISPLAY FORMAT field and clear all Ss in the SEL column. STR7370W LIMITED STROBE NOT ACTIVE. STROBE PACKAGING UTILITY FUNCTIONALITY WILL BE Explanation: The Strobe session manager address space is not active. System Action: Strobe continues processing, but the Strobe Packaging Utility panels do not include the sample and log file dataset names. User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR7371W 3-213 NO SAMPLE DATA SETS. NO CATALOGED DATA SETS WERE FOUND Explanation: specified. The Strobe Packaging Utility did not find as cataloged the sample datasets you System Action: Strobe continues processing without displaying sample datasets. User Response: Enter the names of four cataloged datasets in the SPECIFY INPUT DATA SET NAMES TO INCLUDE field. STR7372E DATA SET PREFIX REQUIRED. AN OUTPUT DATA SET PREFIX MUST BE SPECIFIED Explanation: You did not specify an output dataset prefix during your Strobe Packaging Utility dataset transfer request. System Action: The Strobe Packaging Utility does not process the request. User Response: Specify an output dataset for the prefix and resubmit the Strobe Packaging Utility dataset transfer request. STR7373I VERIFY CANCEL REQUEST. ‘END’ TO EXIT STROBE PACKAGING UTILITY, ‘ENTER’ TO CONTINUE Explanation: This message enables you to verify your request to cancel the Strobe Packaging Utility. System Action: The Strobe Packaging Utility stops processing your request. User Response: Press End to cancel the Strobe Packaging Utility, or press Enter to continue Utility processing. STR7374E Missing Log Dataset(s) STRBPKG - SOME STROBE LOG FILES ARE UNAVAILABLE Explanation: The Strobe Packaging Utility called the dialog service for the names of the Log datasets. One or more of these datasets have become unavailable. They may have been deleted or re-named. System Action: available. The Strobe Packaging Utility continues with those Log datasets that are User Response: Notify the Strobe system programmer. STR7375E OSTARXMT ERROR. text The specified message text is output from the OSTARXMT REXX exec. The following are possible texts: • Workfile SYSUT2 allocation failure Explanation: System Action: The procedure was unable to allocate a temporary work file. Processing terminates. User Response: See other TSO messages and modify the allocation for SYSUT2 in OSTARXMT to conform to local standards. • Invalid control file DSN. Try OSTARXMT with no parms Explanation: The control file STRBPKG is passing to OSTARXMT is invalid. System Action: Processing terminates. User Response: Contact Compuware Customer Support. • Unable to allocate file. ODSN with DISP=NEW Explanation: System Action: The output file cannot be allocated. Perhaps the dataset already exists. Processing terminates. User Response: Delete the existing dataset of the same name. Otherwise, see other TSO messages and modify the dataset name to conform to local standards. • DSN not found. Rejected Explanation: System Action: OSTARXMT could not find the dataset. Processing terminates. 3-214 Strobe Messages Guide User Response: Check that the name was entered correctly using normal TSO naming standards. If the name is not in single quotes it will be prefixed with your user ID. If the name is correct, the dataset is not migrated. If you had a typing error then correct it and retry. • Error writing to ODSN Explanation: Either the output dataset filled up, the volume is full, or you do not have write access to the dataset. System Action: Processing terminates. User Response: If the output dataset has gone to 16 extents then increase the size on the allocate for SYSUT1 in OSTARXMT. • All datasets were not processed, but ‘ODSN’ is valid Explanation: file. This is a warning. The datasets that were specified correctly are in the output System Action: None. User Response: None required. • Unable to copy ‘IDSN’ to workfile Explanation: System Action: The TSO TRANSMIT command failed to write the input file to the work file. Processing terminates. User Response: If this is a large file, try increasing the size of the work file allocated via SYSUT2 in OSTARXMT. Otherwise, check preceding TSO errors. • Read error on temp file Explanation: This should not occur. System Action: Processing terminates. User Response: Record the preceding TSO error messages. • Error writing to output file Explanation: System Action: Either the output file is full or you do not have write access to it. Processing terminates. User Response: If it is full, increase the size of the dataset allocated as SYSUT1 in OSTARXMT. STR7376E OSTARREC ERROR. text Explanation: The specified message text is output from the OSTARREC REXX exec. The following are possible texts: • Error allocating work file Explanation: The procedure was unable to allocate a temporary work file. System Action: Processing terminates. User Response: standards. Modify the allocation for SYSUT2 in OSTARREC to conform to local • Unable to allocate file ‘ISDN’ Explanation: System Action: Allocation of input file failed. Processing terminates. User Response: Check other error messages. Possible errors are security violations or exclusive shares. • Invalid input ‘DSN’ ‘ISDN’. Invalid header Explanation: The input file does not start with the expected header information. Possible causes are transmission error or wrong input dataset used. System Action: Processing terminates. User Response: Correct input dataset name, if incorrect, otherwise, retransmit. • Input file is ‘VERSION.’ You need a new version of ‘OSTARREC’ Messages Produced by Strobe Explanation: 3-215 The file you have uploaded requires a newer version of OSTARREC. System Action: Processing terminates. User Response: Contact Compuware Customer Support. • Read error on input file Explanation: Unable to read the input file. System Action: Processing continues. User Response: See other TSO messages for details. • File level error checking failed Explanation: not 88. File validation failed. Possible reasons include transmission error and LRECL System Action: Processing terminates. User Response: Correct error and retry. • Record level error checking failed Explanation: File validation failed. Transmission error. System Action: Processing terminates. User Response: Correct error and retry. • Write error to temp file Explanation: The temporary work file allocated via SYSUT2 is not big enough. System Action: Processing terminates. User Response: Find the allocate statement for SYSUT2 in OSTARREC and increase the size. • ‘INMR152I’ RECEIVE failed. Sender’s node ID is not recognized Explanation: This message is produced by the TSO RECEIVE command which is used, under covers, by OSTARREC. It is produced when the TSO TRANSMIT/RECEIVE customization has not been performed at the site when TSO/E was installed. System Action: Processing terminates. User Response: Contact your system programmer. STR7378E STRBPKG MUST BE INVOKED VIA 'P' FROM THE STROBE OPTIONS MENU Explanation: You attempted to access the Strobe packaging utility using a command. You must access this utility by selecting P from the Strobe Options menu in Strobe/ISPF. System Action: Strobe does not invoke the packaging utility. User Response: menu. To invoke the packaging utility, select option P from the Strobe Options STR7379W AUTOSTROBE DISABLED AUTOSTROBE ALLOCATION ERROR CAUSED AUTOSTROBE TO BE DISABLED Explanation: A problem occurred during the allocation of a file required by AutoStrobe. System Action: The AutoStrobe option does not appear on the primary Strobe Options menu. User Response: STR7380I jobname Notify the Strobe system programmer. AUTOSTROBE REQUEST ADDED. AN AUTOSTROBE REQUEST HAS BEEN ADDED FOR Explanation: You submitted a measurement request. Strobe/ISPF reports the request number (nnnn) and status in the short message field. If the request was submitted successfully, the jobname appears in the long message field. Otherwise, the return code appears in the short message field and the appropriate error message appears in the long message field. System Action: Strobe successfully processed the request and is waiting for the next request. User Response: None required. 3-216 Strobe Messages Guide STR7381W NO BASIS DATA RECORDS. THE AUTOSTROBE REQUEST HAS NO BASIS DATA RECORDS TO DISPLAY Explanation: Strobe issued this warning in a response to a request to display basis data records associated with an AutoStrobe request which has no such records. System Action: None. User Response: Remove the invalid request. STR7382E ARCHIVE ERROR. error text Explanation: errortext. The history manager has encountered an error. The error is described in System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7383E INVALID STEPNAME. SPECIFY A VALID STEPNAME OR STEP.PROCESTEP NAME Explanation: You entered an invalid step in the STEP field of the Strobe - Add Queued Request panel, or you have chosen Option 2 on the Strobe - Add Queued Request - Multiple Steps panel and specified the name of one or more steps or step.procsteps incorrectly. System Action: Strobe does not process the measurement request. User Response: Supply a relative step number between 1 and 255, or a stepname, or a procstepname and stepname. The stepname or procstepname must contain from 1 to 8 alphanumeric characters. The first characters must be alphabetic or national. The three national characters are @, #, and $. STR7384E NO RECORDS FOUND. NO AUTOSTROBE RECORDS WERE FOUND FOR THE SPECIFIED FILTER CRITERIA Explanation: Strobe issued this message in a response to a request to display AutoStrobe requests based on filter values for the fields: Jobname, Program Stepname, OwnerId, System. No AutoStrobe requests matched the filter. System Action: Strobe does not display any data. User Response: Make the filters less restrictive, using an asterisk (*) as a wildcard character. STR7385E INVALID SESSION/TCP TIME. MUST BE A NUMERIC VALUE FROM 0 TO 9999 Explanation: The value you entered as the SESSION/TCB time minutes threshold is not valid. Valid values are within the range of 0 to 9999. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7386E INVALID SPECIFICATION. VALID OPTIONS ARE "A" OR "Q" OR "B" OR "W" Explanation: B, or W. The value you entered as the request type are not valid. Valid values are A, Q, System Action: Strobe does not process the request. User Response: Enter a valid value. STR7387E UNABLE TO FIND CWPIDRVB CWPIDRVB NOT IN UI_CSSLIB OR LINKLIST Explanation: Strobe/ISPF cannot find CWPIDRVB in a link list dataset or in the dataset specified on the UI_CSSLIB parameter in the Strobe PARMLIB member. System Action: Strobe/ISPF does not process the request. User Response: Notify the Strobe system programmer. STR7388E INVALID SPECIFICATION. SELECT A VALID OPTION AS LISTED ON THE PANEL Explanation: You specified an invalid on the panel. System Action: Strobe/ISPF does not process the request. User Response: Specify a valid option. Messages Produced by Strobe 3-217 STR7389I NO BASIS DATA FOUND. NO BASIS DATA WERE FOUND TO THE SPECIFIED AUTOSTROBE REQUEST Explanation: There are no measurement session basis data records that match the filter criteria that you specified. System Action: Strobe does not process the request. User Response: Enter different filter criteria. STR7390I NO REQUESTS FOUND. NO ARCHIVED REQUESTS WERE FOUND FOR THE SPECIFIED FILTER CRITERIA Explanation: There are no measurement session basis data records that match the filter criteria that you specified. System Action: Strobe does not process the request. User Response: Enter different filter criteria. STR7391I INVALID SCHEDULE. AN AUTOSTROBE REQUEST CANNOT BE SCHEDULED BEYOND A YEAR FROM TODAY Explanation: You attempted to schedule a measurement request element or a request group for more than one year in the future from today’s date. System Action: Strobe/ISPF does not process the request. User Response: On the Strobe - Request Scheduler panel, ensure that the values in the STARTING DATE and ENDING DATE fields represent a time period of one year or less from today’s date, or specify a value in the NUMBER OF WEEKS field that is one year or less from today’s date. STR7392E NO SCHEDULE GENERATED. THERE ARE NO DATE ENTRIES IN THE SCHEDULE Explanation: You attempted to schedule a measurement request or a request group but did not specify the days of the week on which you want the measurement session initiated. System Action: Strobe/ISPF does not process the request. User Response: Enter a Y in the field under one or more of the days shown near the top of the Strobe - Request Scheduler panel, or create a customized list by completing the bottom portion of the panel. STR7393E DUPLICATE ADD CONFLICT. THIS DATE HAS ALREADY BEEN GENERATED IN THE WEEKLY LIST Explanation: You attempted to add an individual date to the weekly schedule for a measurement request or a request group. The date you specified, however, is already included in the weekly schedule. System Action: Strobe does not process the request. User Response: Ensure that the individual date is not included in the weekly schedule designated in the top section of the Strobe - Request Scheduler panel. STR7394E DATE DOES NOT EXIST. THIS DATE DOES NOT EXIST IN THE GENERATED WEEKLY LIST Explanation: You attempted to exclude an individual date from the weekly schedule for a measurement request or a request group. The date and time you specified, however, does not exist in the weekly schedule. System Action: Strobe does not process the request. User Response: Ensure that the individual date is included in the weekly schedule designated in the top section of the Strobe - Request Scheduler panel. STR7396E INVALID SPECIFICATION A THRESHOLD MINIMUM CANNOT BE SPECIFIED WITH THE SUPPRESS OPTION Explanation: You specified a Y in the SUPPRESS field and entered a threshold minimum in the OVERRIDE THESHOLD field. System Action: Strobe does not process the AutoStrobe request. User Response: Enter a threshold minimum or select the SUPRESS option or do neither. 3-218 Strobe Messages Guide STR7397E CANNOT SUPPRESS ALL THRESHOLDS CANNOT ALL BE SUPPRESSED Explanation: You specified Y in the SUPPRESS fields. There must at least one threshold used by AutoStrobe. System Action: Strobe does not process the AutoStrobe request. User Response: Change at least one SUPPRESS field to N. STR7398E CHANGE INVALID ON WARN CANNOT CHANGE MEASUREMENT PARAMETERS IF ACTION IS WARN Explanation: You specified Y in the Change Measurement Parameters field and specified an action of Warn. Measurement parameters do not apply when an action of warn is specified. System Action: Strobe does not process the AutoStrobe request. User Response: Change the action from Warn to a measurement type, (Q, A, or B) or change the Y to N in the Change Measurement Parameters field. STR7402E INVALID FILE FILE IS NOT DDIO OR MAP Explanation: file. You specified a file to use for indexing at was neither a DDIO file nor a map System Action: Strobe does not process the your request. User Response: Enter the correct file name. STR7403E DDIO FILE CODE = xxxx DDIO DATASET VERIFY RETURNED AN INVALID STATE Explanation: The Compuware CSS routine returned a bad return code xxxx to Strobe. System Action: Strobe does not process the your request. User Response: Look up the meaning of the return code in the CSS manual. STR7404E INVALID EXCPS MUST BE A NUMERIC VALUE FROM 20000 TO 2147483647 Explanation: You entered a value that is out of range. System Action: Strobe/ISPF does not process the request. User Response: Enter a value within the minimum or clear the field. STR7405E EXCLUSION ADDED CANDIDATE WAS ADDED TO THE EXCLUSION LIST Explanation: The exclusion record you selected has been updated. System Action: None. User Response: None required. STR7406E INTERNAL ERROR STRBJTG RC = FROM Explanation: An internal error occurred in Java target processing. message text specifies the error location. System Action: Strobe does not process the request. User Response: Notify the Strobe system programmer. STR7407I SELECT A TARGET OR PRESS END TO EXIT Explanation: target. On a targeting panel, you pressed Enter without specifying at least one Java Explanation: Strobe does not process the request. Explanation: Enter or select a target, or press End to exit without adding a target. Messages Produced by Strobe STR7408E 3-219 ERROR IN JAVA SELECTOR PROCESSING: Explanation: A serious error occurred in the Strobe Java Selector processing. See the message text for details about the error that occurred. message text can be: • • • • • • • MVSOUT ALLOCATION RETURN CODE = rc SELECTOR CANNOT BE USED - FILE CANNOT BE ALLOCATED TARGET NOT FOUND. REENTER TARGET OR PRESS END TO EXIT JAVA CLASS SELECTOR RETURN CODE = rc JAVA SELECTOR FILE COPY RETURN CODE = rc TARGETING DATA ERROR: rc (Various other SELECTOR errors) System Action: Strobe does not process the request. User Response: programmer. Correct the error described in the message text or notify the Strobe system STR7409E TARGETS. NUMBER OF TARGETS CANNOT EXCEED . YOU HAVE SELECTED Explanation: On a Strobe Java targeting panel, you selected mmm targets, which is more than the maximum of nnn that can be processed. System Action: Strobe does not process the request. User Response: Delete one or more targets until fewer than nnn targets are selected. STR7410E - STRBJTG MUST BE INVOKED FROM THE STROBE DATA COLLECTORS PANEL Explanation: You attempted to access the Java targeting function (STRBJTG) outside of Strobe/ISPF. You must access this function only from the Strobe - JAVA Data Collector Options panel in Strobe/ISPF. System Action: Strobe does not invoke the Java targeting function. User Response: To run the Java targeting function, invoke Strobe/ISPF and select JAVA Targeting Data from the Strobe - JAVA Data Collector Options panel. STR7411E DUPLICATE RECORD THIS RECORD ALREADY EXISTS ON THE FILE Explanation: The exclusion record you entered already exists on the file. System Action: Strobe/ISPF does not process the request. User Response: Ensure that the exclusion record that you add does not already exist. STR7413E INVALID MAP FILE Explanation: The file you specified does not meet MAP file requirements. A MAP file can be specified as a PS or a PDS(mbr) dataset. System Action: Strobe/ISPF does not process the request. User Response: Specify a valid MAP file. STR7419E DATE-LOADLIB-OPTION REQ. START DATE, UPDATE OPTION AND AT LEAST ONE LOADLIB ARE REQUIRED Explanation: You requested to build an AutoMeasure load module list, but did not specify a value for the start date, the update option, or a name of a load library to be searched. System Action: Strobe does not process the request. User Response: Enter the missing values in the appropriate fields. STR7420I NO RECORDS FOUND. NO AUTOMEASURE RECORDS WERE FOUND FOR THE SPECIFIED FILTER Explanation: Strobe could not find any AutoMeasure records for the values specified on the Strobe - AutoStrobe Automeasure Utility panel or the AutoMeasure utility has not been run. System Action: No records are displayed. 3-220 Strobe Messages Guide If the AutoMeasure utility has not been run, go to Option 5 on the Strobe AutoStrobe Options panel, and run the utility. If it has been run, change the values User Response: specified on the Strobe - AutoStrobe Automeasure Utility panel to include more records. STR7421E INVALID DATE. DATE IS IN INVALID FORMAT Explanation: System Action: You used an invalid format for the date. Strobe does not process the request. User Response: Enter the date using the format that was specified in the parameter dataset when Strobe was installed. The default format is DD/MM/YY. The value for the day must be from 1 to 31, and the value for the month must be from 1 to 12. STR7422E INVALID SPECIFICATION. VALID OPTIONS ARE "R" OR "U" Explanation: You entered an invalid list option on the Strobe - AutoStrobe Automeasure Utility panel. Valid values are R for Replace or U for Update. System Action: Strobe does not process the request. User Response: Enter a valid value. STR7424E PERIOD INCOMPLETE. PERIOD STARTING AND ENDING TIMES ARE REQUIRED Explanation: The collection period on the AutoStrobe Create Transaction Candidates request is incomplete. Each collection period must have a starting and ending time. System Action: Strobe does not process the request. User Response: Supply the missing information. STR7425E PERIOD INVALID. CANDIDATE COLLECTION ENDING TIME MUST BE GREATER THAN STARTING TIME Explanation: The AutoStrobe Create Transaction Candidates request has an invalid collection period. System Action: Strobe does not process the request. User Response: starting time. Change the ending time of the collection period so that it occurs after the STR7426E OVERLAP PERIODS OVERLAP. TRANSACTION CANDIDATE COLLECTION PERIODS MAY NOT Explanation: The AutoStrobe Create Transaction Candidates request has an invalid collection period. Collection periods cannot overlap. System Action: Strobe does not process the request. User Response: Change the time ranges of the collection periods so they do not overlap. STR7427E DAYS OUT OF RANGE. TRANSACTION CANDIDATE COLLECTION NUMBER OF DAYS MUST BE BETWEEN 1 AND 31 Explanation: The AutoStrobe Create Transaction Candidates request has an invalid number of collection days. The number must be from 1–31 days. System Action: Strobe does not process the request. User Response: Type a number from 1–31 in the Days to Collect field. STR7428E MIN TRAN COUNT INVALID. TRANSACTION CANDIDATE COLLECTION MINIMUM TRAN COUNT MUST BE BETWEEN 1 AND 9999 Explanation: The AutoStrobe Create Transaction Candidates request has an invalid minimum transaction count. The minimum qualifying transaction count must be from 1— 9999 transactions. System Action: Strobe does not process the request. User Response: Type a number from 1–9999 in the Qualifying Minimum Tran Count field. Messages Produced by Strobe 3-221 STR7429E MIN RESP TIME INVALID. TRANSACTION CANDIDATE COLLECTION MINIMUM RESPONSE TIME MUST BE BETWEEN .1 AND 999.9 seconds Explanation: The AutoStrobe Create Transaction Candidates request has an invalid minimum response time. The minimum qualifying response time must be from .1–999.9 seconds. System Action: Strobe does not process the request. User Response: field. Type a number from .1–999.9 in the Qualifying Minimum Response Time STR7430E MIN CPU TIME INVALID. TRANSACTION CANDIDATE COLLECTION MINIMUM CPU TIME MUST BE BETWEEN .00001 AND 9.99999 seconds Explanation: The AutoStrobe Create Transaction Candidates request has an invalid minimum CPU time. The minimum qualifying CPU time must be from .00001–9.99999 seconds. System Action: Strobe does not process the request. User Response: field. Type a number from .00001–9.99999 in the Qualifying Minimum CPU Time STR7431E INSUFFICIENT DATA. THE TRANSACTION CANDIDATE DATA COLLECTED IS NOT SUFFICIENT TO CALCULATE THRESHOLDS Explanation: Sufficient data for a transaction candidate detail is available when: • The candidacy period is completed (Days to Collect) • AutoStrobe has collected data for at least three days System Action: Strobe does not process the request. User Response: Determine when AutoStrobe has collected data for at least three days or when the candidacy period is completed, and view the transaction candidate detail after that time. STR7432E SELECT ONLY 5 TRAN ID'S. THE MAXIMUM NUMBER OF TRANSACTIONS THAT CAN BE SPECIFIED IS 5. PLEASE SELECT NO MORE THAN 5 TRANSACTION ID'S Explanation: The Add AutoStrobe Transaction request or an Add Active request is invalid, because you selected more than five transactions from the Strobe - AutoStrobe Candidate Transaction Detail panel. System Action: Strobe does not process the request. User Response: Select no more than five transactions. STR7433E SPECIFICATION INCOMPLETE. JOBNAME, PROGRAM AND AT LEAST ONE TRANSACTION NAME REQUIRED Explanation: The Add AutoStrobe Transaction request is incomplete. The monitoring request must have at a minimum: a job name, program name, and at least one transaction. System Action: Strobe does not process the request. User Response: Supply the missing information. STR7434E MINUTES ANALYSIS INTVL INVALID. ANALYSIS INTERVAL MUST BE A VALUE BETWEEN 5 AND 60 Explanation: The Add AutoStrobe Transaction request has an invalid analysis interval. The analysis interval must be from 5–60 minutes. System Action: Strobe does not process the request. User Response: Type a number from 5–60 in the Analysis Interval field. STR7435E SPECIFY TRANSACTION. A TRANSACTION MONITOR PERIOD, RESPONSE TIME OR CPU TIME THRESHOLD WAS SPECIFIED WITHOUT TRANSACTION NAME Explanation: The Add AutoStrobe Transaction request is incomplete. A transaction threshold was specified on the monitoring request without a transaction name. System Action: Strobe does not process the request. User Response: Type a transaction name in the Tran Id field. 3-222 Strobe Messages Guide STR7436E PERIOD INCOMPLETE. TRANSACTION MONITOR PERIOD STARTING AND ENDING TIMES ARE REQUIRED Explanation: The Add AutoStrobe Transaction request is incomplete. A monitoring period is missing a starting or ending time. System Action: Strobe does not process the request. User Response: Supply the missing information. STR7437E PERIOD INVALID. TRANSACTION MONITOR ENDING TIME MUST BE AT LEAST 5 MINUTES GREATER THAN STARTING TIME Explanation: The Add AutoStrobe Transaction request has an invalid monitoring period. The ending time of the monitoring period must be greater than the starting time by at least five minutes. System Action: Strobe does not process the request. User Response: Change the ending time of the monitoring period so that it is at least five minutes greater than the starting time. STR7438E PERIODS OVERLAP. TRANSACTION MONITOR PERIODS MAY NOT OVERLAP Explanation: The Add AutoStrobe Transaction request has an invalid monitoring period. The monitoring periods overlap. System Action: Strobe does not process the request. User Response: Change the time ranges of the monitoring periods so they do not overlap. STR7439 THRESHOLD INVALID. A TRANSACTION CPU OR RESPONSE TIME THRESHOLD IS INVALID OR OUT OF RANGE Explanation: A transaction threshold is invalid on the Add AutoStrobe Transaction request. The range of valid values for the CPU threshold are .00001–9.99999 seconds. The range of valid values for the response time threshold is 0.1–999.9 seconds. System Action: Strobe does not process the request. User Response: Type a number from .00001–9.99999 in the CPU threshold field; or type a number from 0.1–999.9 in the Response threshold field. STR7445E INVALID SPECIFICATION. VALID SELECTION FOR DDF REQUESTER IS 'P' FOR PRIMARY OR 'S' FOR SECONDARY Explanation: You typed a value other than P, S, or blank in one of the DDF requester fields. System Action: Strobe does not process the request. User Response: Correct the invalid field. STR7446E 1 P REQUIRED, S OPTIONAL. ENTER ONE 'P' FOR PRIMARY AND OPTIONALLY ONE 'S' FOR SECONDARY Explanation: System Action: You typed more than one P or S, or you typed an S without a P. Strobe does not process the request. User Response: Select the Primary DDF Requester using a P and, optionally, one Secondary DDF Requester using an S. STR7447E FILTERS MAX OF 2 FILTERS ALLOWED. USE ONLY FIELDS USED AT MEASUREMENT FOR Explanation: You entered filters for more than two DDF requesters. Only two DDF requesters are permitted; therefore, only two DDF filters are allowed. System Action: Strobe does not process the request. User Response: measurement. Only specify filters in the fields corresponding to the DDF requesters used at STR7448E INVALID THRESHOLD VALUE. MUST BE A NUMERIC VALUE FROM 0 TO 99.99999 Explanation: You typed an invalid value for the threshold. Valid values are 0–99.99999 seconds. Specify the value in nn.nnnnn format. Messages Produced by Strobe System Action: Strobe does not process the request. User Response: Type a valid value for the threshold. STR7450I 3-223 NO RECORDS WERE FOUND FOR THE SPECIFIED CRITERIA Explanation: No event records match the ownerid that you specified. System Action: Strobe does not process the request. User Response: Enter a different ownerid. STR7451E DUPLICATE EVENT NAME THE SPECIFIED EVENT ALREADY EXISTS Explanation: exists. You attempted to create a new event, but an event with this name already System Action: Strobe does not process the request. User Response: Choose a unique name for the event. STR7452E ALL FIELDS REQUIRED ENTER A VALUE IN ALL 5 FIELDS Explanation: You attempted to create or update an event, but required information is missing. Enter a value, or clear the field to use the default. If there is no default, you must enter a value. System Action: Strobe does not process the request. User Response: Supply the required information. STR7453E EVENT NAME NOT FOUND NAME IS NOT AN EXISTING EVENT Explanation: You specified an event name, but AutoStrobe cannot locate that event. System Action: Strobe does not process the request. User Response: Supply an existing event or add and specify a new one. STR7454E MORE THAN ONE SELECTED SELECT ONLY ONE EVENT Explanation: You selected more than one event for a request. System Action: Strobe does not process the request. User Response: Resubmit the request and specify no more than one event. STR7455E STEP INVALID ON IMMED RQ A MONITOR IMMEDIATE OR CANDIDATE IMMEDIATE REQUEST MAY NOT INCLUDE A STEP NAME Explanation: The AutoStrobe transaction monitoring or create transaction candidates request is invalid, because you specified Monitor Immediate or Immediate Eligibility and also specified a step name. System Action: Strobe does not process the request. User Response: Resubmit the request and specify either Monitor Immediate or a step name. STR7456E This field should be left blank when the output format is an iStrobe file. Explanation: When the OUTPUT FORMAT is I for iStrobe, the fields NUMBER OF COPIES FOR BACKGROUND REPORTS and DATASET NAME for a saved copy of the Strobe Profile have no meaning and should be left blank. System Action: Strobe/ISPF dialog waits for correct entry. User Response: dialog. Blank out the specified input fields and continue with the Profile creation STR7457E Please enter the name of a supported code page. Explanation: The translation code page specified is not supported. 3-224 Strobe Messages Guide System Action: Strobe/ISPF dialog waits for correct entry. User Response: Enter one of the following supported code pages: • • • • • • • • • • • • • • IBM-STD : Latin 1/Open Systems (default) IBM-037 : USA/Canada IBM-273 : German IBM-277 : Danish IBM-278 : Swedish IBM-280 : Italy IBM-284 : Spanish IBM-285 : United Kingdom IBM-297 : French IBM-423 : Greek IBM-424 : Israel IBM-500 : Switzerland IBM-870 : Polish IBM-875 : Greek STR7466I An element has been added to the group. End of selection list for Active Jobs. Explanation: You added a request group element to the group. Strobe has processed the last of a list of Jobs for Add Active element processing. System Action: Strobe successfully processed the request and is waiting for the next request. User Response: None required. STR7467I Req nnnn has been added for jjjjjjjj . End of selection list for Active Jobs/UNIX Processes/Agents. Explanation: Request nnnn has been added for the named job jjjjjjjj . Strobe has processed the last of a list of active Jobs /UNIX Processes / Agents. System Action: Strobe successfully processed the request and is waiting for the next request. User Response: None required. STR7468E Invalid High Level Qualifier For Temporary Datasets. The entered temporary dataset high level qualifier is invalid. Explanation: name. System Action: You specified a non-acceptable high-level qualifier for your temporary dataset Strobe/ISPF dialog waits for correct entry. User Response: Enter a valid high-level qualifier for your temporary dataset name. You may blank out the field and press Enter to restore the default value. The default value may be the TSO userid or TSO profile prefix. STR7469E ISPF FTINCL service failed with RC(nn) for the JCL skeleton member, xxxxxxxx. JCL generation can not continue. Explanation: The ISPF file tailoring service FTINCL has failed with a return code of nn, processing the JCL skeleton member, xxxxxxxx. Strobe can not build the requested JCL. Please check that the Strobe JCL skeleton library is included in the ISPSLIB concatenation. System Action: Strobe will not allow further JCL build processing. User Response: Contact your Strobe administrator. STR7475E Missing Log Dataset(s) STRBPKG - SOME STROBE LOG FILES ARE UNAVAILABLE Explanation: The Strobe Packaging Utility called the dialogservice for the names of the Log datasets. One or more of these datasets have become unavailable. They may have been deleted or re-named. System Action: The Strobe Packaging Utility continues with those datasets that are available. User Response: STR7501E None required. ERROR OCCURRED DURING UNMARSHALLING OF THE REQUEST MSG Explanation: Strobe transfer client encountered an error while reading. Messages Produced by Strobe System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7504E ERROR OCCURRED WHILE EXECUTING THE SAVE REQUEST Explanation: Strobe transfer client encountered an error during the SAVE process. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7507E REQUESTED FILE OR DIRECTORY COULD NOT BE FOUND AS SPECIFIED Explanation: Strobe transfer client could not find the directory as specified. System Action: Strobe terminates the download. User Response: Correct the directory and resubmit. STR7508E WRITE ACCESS FAILED FOR FILE OR DIRECTORY Explanation: Strobe transfer client encountered a directory with “Write access denied”. System Action: Strobe terminates the download. User Response: Correct access to the directory or chose another directory. STR7511E NEW DIRECTORY REQUEST FAILED: DIRECTORY ALREADY EXISTS Explanation: Strobe transfer client encountered a directory error. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7512E 3-225 SAVE OF PROFILE FAILED WITH VERIFY ERROR Explanation: System Action: Strobe transfer client encountered a directory error during SAVE processing. Strobe terminates the download. User Response: Check the iStrobe Manager log for details, and correct the directory error. If the problem persists, contact Compuware Customer Support. STR7513E WRITE ERROR OCCURRED DURING DOWNLOAD OF PROFILE Explanation: Strobe transfer client encountered an error during SAVE processing. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7514E SAVE FAILED ON PROFILE DATA TRANSMIT ERROR Explanation: Strobe transfer client encountered an error during transmit processing. System Action: Strobe terminates the download. User Response: Rerun the job or contact Compuware Customer Support. STR7515E DESTINATION FOR PROFILE IS NOT A VALID PATH FOR THIS SERVER Explanation: Strobe transfer client could not find the directory in the directory list. Valid directories can be found in the transfer client message following this message. System Action: Strobe terminates the download. User Response: Correct the directory and resubmit. STR7516E PROFILE LOCATIONS ARE NOT DEFINED. CONTACT YOUR ISTROBE ADMINISTRATOR Explanation: The iStrobe manager configuration does not define the Profile Locations. System Action: Strobe terminates the download. User Response: Contact your iStrobe administrator. 3-226 Strobe Messages Guide STR7518E SAVE ACCESS WAS DENIED FOR THE PROTECTED FOLDER Explanation: Cannot create the target file in the directory specified. Check directory permissions or specify a folder to which you have write access. The target file location is given in the additional messages listed after this message. System Action: Strobe terminates the download. User Response: Contact your iStrobe administrator. STR7520E EMAIL NOTIFICATION WAS REQUESTED BUT FAILED Explanation: The iStrobe manager configuration does not have the mail server installed. System Action: Strobe terminates the download. User Response: Contact your iStrobe administrator. STR7521E RESPONSE RETURN CODE OR MESSAGE NUMBER IS INVALID, RESPONSE FOLLOWS Explanation: Strobe transfer client encountered an error. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7522E EMAIL NOTIFICAION WAS IGNORED, CONFIGURATION HAS NOT BEEN PERFORMED Explanation: The iStrobe manager e-mail configuration has not been performed. The mail server smtpservr is configured to send from sender [email protected]. The Profile has been processed and can be viewed in iStrobe via the open profiles dialog. System Action: None. User Response: Contact your iStrobe administrator. STR7530E LMS CHECKOUT FAILURE Explanation: Strobe transfer client encountered an error during LMS processing. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7531E THE RESPONSE MESSAGE DID NOT CONTAIN THE EYECATCHER Explanation: Strobe transfer client encountered an error with the transmitted data. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7532E PROPERTIES MODULE WAS NOT LOADED Explanation: Strobe transfer client encountered an error processing the HOST data. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7533E RETURN CALL TO GETRETURNEDMESSAGE WAS MADE AND THERE WAS NO MESSAGE TO Explanation: Strobe transfer client encountered an error processing the RETURNMESSAGE. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7534E UNICODE CONVERSION ERROR ON REQUEST MESSAGE Explanation: Strobe transfer client encountered an error processing the Unicode conversion. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7535E UNICODE CONVERSION ERROR ON RESPONSE MESSAGE Explanation: Strobe transfer client encountered an error processing the Unicode conversion. Messages Produced by Strobe System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7536E SENDING DATA ON A SOCKET FAILED Explanation: Strobe transfer client encountered an error during SEND processing. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7537E CONNECTION HAS BEEN LOST Explanation: Strobe transfer client encountered a Lost Connection. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7538E UNABLE TO LOCATE THE SERVER ADDRESS Explanation: supplied. Strobe transfer client could not connect to the server address/IP address System Action: Strobe terminates the download. User Response: Correct the server address/IP address and resubmit the job. STR7539E 3-227 SOCKET CREATION FAILED Explanation: Strobe transfer client could not connect to the server address/IP address and/or PORT supplied. System Action: Strobe terminates the download. User Response: Correct the server address/IP address and resubmit the job. If the job continues to fail, contact Compuware Customer Support. STR7540E SERVER ADDRESS IS NOT AVAILABLE Explanation: Strobe transfer client could not connect to the server address/IP address and/or PORT supplied from the system. System Action: Strobe terminates the download. User Response: Correct the server address/IP address and resubmit the job, and/or check with your network administrator for connection verification. If the job continues to fail, contact Compuware Customer Support. STR7541E SERVER REFUSED THE CONNECTION Explanation: System Action: Strobe transfer client encountered a “connection” refused. Strobe terminates the download. User Response: Correct the server address/IP address and resubmit the job, and/or check with your network administrator for connection verification. If the job continues to fail, contact Compuware Customer Support. STR7542E THE CONNECTION FAILED Explanation: System Action: Strobe transfer client could not establish a connection with the network. Strobe terminates the download. User Response: Check with your network administrator for connection verification. If the job continues to fail, contact Compuware Customer Support. STR7543E DISCONNECT MESSAGE WAS RECEIVED Explanation: Strobe transfer client connection was terminated. System Action: Strobe terminates the download. User Response: Support. Resubmit the job. If the job continues to fail, contact Compuware Customer 3-228 Strobe Messages Guide STR7544E TCP/IP ERROR OCCURED RECEIVING THE DATA Explanation: Strobe transfer client received an error during RECEIVE processing. System Action: Strobe terminates the download. User Response: Support. Resubmit the job. If the job continues to fail, contact Compuware Customer STR7545E SESSION HANDSHAKE ERROR Explanation: Strobe transfer client encountered a handshake error. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7546E ERROR OCCURRED DURING THE SESSION HANDSHAKE Explanation: Strobe transfer client encountered a session handshake error. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support STR7547E UCS ERROR OCCURRED WITH DATA SENT Explanation: manager. Strobe transfer client encountered a UCS error sending data to the iStrobe System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support STR7548E UCS ERROR OCCURRED WITH THE DATA RECEIVED Explanation: manager. Strobe transfer client encountered a UCS error receiving data from the iStrobe System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support STR7550E UNKNOWN ERROR RETURNED, RC=xxxxxxxx Explanation: Strobe transfer client encountered an unknown error. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7560E FAILED TO OPEN SYSPRINT. CHECK THAT IT IS ALLOCATED. Explanation: SYSPRINT allocation failed. System Action: Strobe terminates the download. User Response: Check for SYSPRINT DD card or Contact Compuware Customer Support. STR7561E FAILED TO OPEN ISTRIN. CHECK THAT IT IS ALLOCATED. Explanation: ISTRIN allocation failed. System Action: Strobe terminates the download. User Response: Check for ISTRIN DD card or Contact Compuware Customer Support. STR7562E FAILURE LOADING MODULE Explanation: Internal LOAD failure for the module specified. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7563I Explanation: System Action: Informational message used to display the transfer parameters. None. Messages Produced by Strobe User Response: STR7564E 3-229 None required. PARM ERROR FOR Explanation: Specified parameter is invalid. System Action: Strobe terminates the download. User Response: Correct the parameter on the Strobe - Produce a Performance Profile panel. STR7570E DYNAMIC ALLOCATION RC=XXXX ERROR=XXXX INFO=XXXX Explanation: System Action: The PROFILE specified cannot be allocated. Strobe terminates the download. User Response: Verify and correct the Sample Dataset Name parameter on the Strobe Produce a Performance Profile panel. STR7571E INPUT PROFILE DATASET FAILED TO OPEN Explanation: System Action: The PROFILE specified cannot be OPENed. Strobe terminates the download. User Response: Verify and correct the Sample Dataset Name parameter on the Strobe Produce a Performance Profile panel. STR7572E PROFILE DATASET PROCESSING FAILED Explanation: System Action: Error reading the PROFILE dataset. Strobe terminates the download. User Response: Verify the PROFILE contains data and resubmit. If the job continues to fail, contact Compuware Customer Support. STR7573E TRANSFER RESPONSE IS NULLS Explanation: The response from the iStrobe server is null. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7574E TRANSFER RESPONSE IS NOT NULL TERMINATED Explanation: The response from the iStrobe server is not null terminated. System Action: Strobe terminates the download. User Response: Contact Compuware Customer Support. STR7575I TRANSFER COMPLETE, TERMINATING Explanation: The transfer has completed, and termination is being performed. System Action: None. User Response: None Required. STR7576I COS TRANSFER, transfer status Explanation: Information returned from the COS Alert processor. System Action: None. User Response: None. STR7700E message_text Explanation: STRBGMCL found an error in the criteria request. Message_text contains one of the following: • INVALID CHARACTER IN COLUMN • INVALID FIELD LENGTH: length • INVALID PARAMETER: parm System Action: The current request is terminated. 3-230 Strobe Messages Guide User Response: STR7701E Resolve the error accordingly. DYNAMIC ALLOCATION RETURN CODE=RETC ERROR=ERRC INFO=INFC Explanation: Dynamic Allocation encountered an error. System Action: Processing terminates. User Response: Verify and correct the Criteria Dataset based on the error codes returned. STR7702E SUBT for RQST request. PGM=PRGM Explanation: A common VSAM error occurred accessing a Strobe Monitoring criteria dataset data record. The VSAM error and criteria utility command are shown in the message. System Action: Processing continues. User Response: Resolve the error accordingly. STR7703E RACF Authorization checking failed. VSAM r/c=RETC Error=ERRC PGM=PRGM Explanation: RACF denied access to the Strobe Monitoring criteria dataset. The VSAM return code and error code are displayed in this message. The name of the program is also shown in this message. System Action: Processing terminates. User Response: See the job log for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STR7704E Strobe signature not active. Explanation: Strobe signature is not currently active. System Action: Processing terminates. User Response: Initialize Strobe signature to continue. STR7706I Global Monitoring criteria refreshed Explanation: A request to refresh Global Monitoring criteria in the MNAS was successful. System Action: criteria dataset. The criteria in an active MNAS is updated using the current data in the User Response: None. STR7707E Global Monitoring criteria refresh request failed Explanation: System Action: A request to refresh Global Monitoring criteria failed in the MNAS. The criteria in the MNAS is not updated. User Response: Check the MNAS STRDLOG message log dataset for messages pertaining to the criteria REFRESH request. STR7708E Global Monitoring Name/Token pair not found Explanation: A request to refresh Global Monitoring criteria failed because the Name/Token pair representing the Global Monitoring Address space was not found. System Action: The criteria in the MNAS is not updated. User Response: Ensure that the Global Monitoring address space is active. STR7709E Unable to connect to the Global Monitoring address space Explanation: A request to refresh Global Monitoring criteria failed. The Name/Token pair representing the Global Monitoring Address space (MNAS) was found. Either the MNAS was not active on the system or another error occurred attempting to connect to the MNAS. System Action: The criteria in the MNAS is not updated. User Response: Ensure that the Global Monitoring Address Space is active. If the MNAS is active, check the message log dataset for error messages. Messages Produced by Strobe STR7710E 3-231 Unable to process refresh request at this time Explanation: A request to refresh Global Monitoring criteria failed. The MNAS is currently processing another request. System Action: The criteria in the MNAS is not updated. User Response: Retry the REFRESH request at a later time. STR7711E Criteria dataset not allocated Explanation: A request to access the Global Monitoring criteria dataset failed. The dataset name specified for the GM_CRITERIA_DSN parameter is not allocated. System Action: Criteria processing stops. User Response: Verify the Global Monitoring criteria dataset name. STR8040E STRBD2PP: Unexpected Origination Code Explanation: An unexpected origination code was sent to SQLAF on Demand. System Action: The SQLAF on Demand request will fail. User Response: Contact Compuware Technical Support. STR8041E STRBD2PP: Unable to retrieve the DB2 SSID for Location: "location name" Explanation: System Action: An attempt was made to determine the DB2 subsystem ID based on a location. The SQLAF on Demand request will fail. User Response: Verify that the DB2 subsystem associated with the location specified on the message is active. Otherwise, contact Compuware Technical Support. STR8042E STRBD2PP: Unable to allocate storage for DB2 Catalog Access Explanation: The SQLAF on Demand request cannot continue because storage for an interal work area could not be obtained. System Action: The SQLAF on Demand request will fail. User Response: Notify the Strobe system programmer. STR8043E STRBD2PP: Unable to load: "module name" Explanation: The SQLAF on Demand request cannot continue because the module named in "module name" could not be found. System Action: The SQLAF on Demand request will fail. User Response: Strobe was unable to connect to DB2. Notify the Strobe system programmer. STR8044E STRBD2PP: Unable to connect to DB2: RC=xxxxxxxx RSN=xxxxxxxx Explanation: The SQLAF on Demand request cannot continue because Strobe was unable to connect to DB2. System Action: The SQLAF on Demand request will fail. User Response: Notify the Strobe system programmer or DB2 DBA. Refer to IBM's DB2 for z/OS Messages manual for the return codes and reason codes. STR8045E STRBD2PP: The DBRM (STRDFIFM) for SQLAF on Demand has not been bound Please execute Bind Explanation: The SQLAF on Demand request cannot continue because the DBRM (STRBDFIFM) has not been bound. System Action: The SQLAF on Demand request will fail. User Response: Notify the Strobe system programmer or DB2 DBA. STR8046E STRBD2PP: Public access has not been granted to SQLAF on Demand's Plan (STRANANA) - Please execute Grant Explanation: The SQLAF on Demand request cannot continue because Public access has not been granted. 3-232 Strobe Messages Guide System Action: The SQLAF on Demand request will fail. User Response: Notify the Strobe system programmer or DB2 DBA. STR8047E STRBD2PP: Unexpected SQLCODE encountered in function: xxxxxxxx SQLCODE: xxx Explanation: The SQLAF on Demand request cannot continue; an unexpected SQLCODE was encountered. System Action: The SQLAF on Demand request will fail. User Response: Contact Compuware Technical Support. STR8048E STRBD2PP: Unknown Statement Type Encountered: "statement type" Explanation: An unknown statement type was encountered. System Action: The SQLAF on Demand request will fail. User Response: Contact Compuware Technical Support. STR8049E STRBD2PP: Release Level Mis-Match: xxxxxxxx "strobe module name" = xxxxxxxx Explanation: The release level from module STRBD2PP does not match the release level of the named module shown in the error message: System Action: The SQLAF on Demand request will fail. User Response: The module named in the error message should be in the same library that STRBD2PP resides in and must be at the same Strobe release level. For additional assistance, contact Compuware Technical Support. Messages Returned by Attribution Data Collectors Data collectors for attribution routines return the following messages. STR8110E GETMAIN FAILURE IN program name - UNABLE TO COLLECT ATTRIBUTION DATA Explanation: area. The named Strobe program was unable to obtain virtual storage for its work System Action: Strobe continues sampling without collecting attribution data. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system STR8120E INVALID INPUT TO modname - ATTRIBUTION WILL BE INCOMPLETE Explanation: Strobe called the attributor module modname incorrectly. System Action: Strobe continues sampling without the attribution data and places a dump of the request block in the sample dataset. User Response: STR8130E Notify the Strobe system programmer. STROBE DOES NOT SUPPORT MEASUREMENT OF lang UNDER subsys Explanation: You requested attribution data for the language lang, but Strobe does not support programs in the language under the subsystem named in subsys. System Action: Strobe continues sampling without attribution data. User Response: Notify the Strobe system programmer. STR8140E NOSYNCH IN EFFECT - subsys ATTRIBUTOR DISABLED Explanation: The measurement session is running with NOSYNCH. System Action: Strobe continues sampling without collecting attribution data for the subsystem subsys. User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR8205E 3-233 ABEND LIMIT EXCEEDED - CICS ATTRIBUTOR DISABLED Explanation: Strobe for CICS cannot collect attribution data because it encountered a severe error. System Action: Strobe continues sampling without CICS attribution data. User Response: Notify the Strobe system programmer. STR8206E MAX NUMBER JVM PROFILES PROCESSED - STRBDKXX DISABLED Explanation: Strobe will collect Java environment data for up to 50 JVM Profiles seen active in the measured CICS address space. System Action: If more than 50 JVM Profiles were seen active during measurement, only data for the first 50 will be reported. User Response: STR8207W None required. FAILURE ATTEMPTING TO PROCESS JVM PROFILE INFORMATION Explanation: Strobe will collect Java environment data for up to 50 JVM Profiles seen active in the measured CICS address space. System Action: If more than 50 JVM Profiles were seen active in the same sample, Strobe will collect data for only the first 50. On later samples, Strobe will collect environment data for JVM Profile it had not yet processed. User Response: STR8300E None required. UNACCEPTABLE PARAMETERS PASSED; STRBASSA DISABLING Explanation: list. Strobe called the IMS attributor module STRBASSA with an invalid parameter System Action: Strobe continues sampling without IMS DL/I attribution data. User Response: Notify the Strobe System programmer. STR8301W UNABLE TO RECORD DL/I INFORMATION; ATTRIBUTION REPORTS WILL BE INCOMPLETE Explanation: The IMS attributor cannot collect DL/I attribution data because it encountered a severe error. System Action: Strobe continues sampling, but IMS DL/I attribution data will be incomplete. User Response: Notify the Strobe system programmer. STR8302E ABEND TOLERANCE EXCEEDED FOR STRBASSA - MODULE DISABLED. TRACE  VECTOR = text Explanation: The IMS attributor cannot collect DL/I attribution data because it encountered a severe error. The message text text is critical in analyzing this problem. System Action: Strobe continues sampling without IMS DL/I attribution data. User Response: Save the message text and notify the Strobe system programmer. STR8304I DL/I CAPTURE ACTIVE, TCB=addr Explanation: Strobe activated DL/I capture at task control block address addr. System Action: None. User Response: None required. STR8306E AN ERROR DISABLED DL/I CAPTURE Explanation: The DL/I capture experienced severe errors. System Action: Strobe continues sampling but will not capture DL/I calls. Strobe will produce a Performance Profile, but the transaction counts and service time data on the Transaction Summary report can be inaccurate. DL/I counts will not be produced. User Response: Problem may be caused by running Strobe measurement against a program that is using an incompatible product such as BMC AR/CTL. Check the log for additional error messages and notify the Strobe system programmer. 3-234 Strobe Messages Guide STR8307W THE DL/I CAPTURE LOST DATA - TRANSACTION COUNTS MAY BE INACCURATE Explanation: The DL/I capture routine could not collect data on all IMS transaction counts during measurement. Additional DL/I capture routine messages appear in the Strobe log. System Action: Strobe produces the Performance Profile, but IMS transaction counts and service times could be inaccurate. User Response: Check for application abends in the Message Processing Region or other DL/I capture messages in the Strobe MPR log. Notify the Strobe system programmer. STR8308E DL/I CAPTURE INTERNAL ERROR nn Explanation: A failure occurred in DL/I capture processing. This message may be accompanied by other DL/I capture messages in the Strobe log. System Action: inaccurate. User Response: STR8309I Strobe continues processing; transaction counts and service times could be Notify the Strobe system programmer. TRANSACTION SWAPS DISABLED MEASUREMENT xxx TIMES. DL/I OR TRANSACTION COUNTS MAY BE INACCURATE. Explanation: The Strobe DL/I measurement routine is not able to collect IMS transaction counts while it is disabled. The measurement is disabled by IMS when the region is swapping transactions and an error starting the new transaction occurs. Additional IMS capture messages may occur in the Strobe log or in the job log of the IMS MPR being measured. xxx in the message is replaced by the number of intervals Strobe was disabled. System Action: Strobe produces the Performance Profile, but IMS transaction counts and service times will not include statistics Strobe could not collect while it was disabled. User Response: Resolve any application abends indicated in the MPR being measured; otherwise, no action required. STR8430E GETMAIN FAILURE IN STRBDSNA FOR block - DBRM ATTRIBUTION DISABLED Explanation: Strobe cannot obtain enough storage for block, where block may be the DCI WORKAREA or STAGING AREA. System Action: Strobe continues sampling without DBRM attribution data. Strobe will not identify the DBRMs and SQL statements responsible for DB2 CPU activity in the Strobe Performance Profile. User Response: programmer. STR8431E Increase the region size and resubmit the request. Notify the Strobe system UNABLE TO LOCATE SYSTEM TABLE - DBRM ATTRIBUTION DISABLED Explanation: Strobe cannot locate an internal table. System Action: Strobe continues sampling without DBRM attribution data. Strobe will not identify the DBRMs and SQL statements responsible for DB2 CPU activity in the Strobe Performance Profile. User Response: STR8432W GETMAIN FAILURE IN STRBDSNA FOR block - SOME DBRMS MAY NOT BE MAPPED Explanation: • • • • • • Notify the Strobe system programmer. Strobe cannot obtain enough storage to map the DBRMs. block may be: R24 WORKAREA SQL BUFFER DBRM TABLE READ ROUTINE BLDL LIST DCB System Action: Strobe continues sampling, but some of the DBRMs reported in the Performance Profile may not be indexed. User Response: programmer. Increase the region size and resubmit the request. Notify the Strobe system Messages Produced by Strobe STR8436E 3-235 I/O ERROR, SYNAD EXIT ENTERED dsname, synadaf message Explanation: Strobe encountered an I/O error using dataset dsname, probably because of a hardware problem. Strobe displays the message from the MVS I/O error handler. System Action: Strobe continues sampling, but it may not index some of the DBRMs reported in the Performance Profile. User Response: STR8437E Notify the Strobe system programmer. I/O ERROR, DCB ABEND EXIT ENTERED Explanation: Strobe encountered an I/O error processing the DBRM dataset and has invoked its DCB exit routine. System Action: Strobe continues sampling, but it may not index some of the DBRMs reported in the Performance Profile. User Response: Notify the Strobe system programmer of the problem. STR8439W UNABLE TO OBTAIN ADB/CPDATA - SOME DBRM ATTRIBUTION INFORMATION MAY BE MISSING Explanation: Strobe encountered an error while obtaining an internal work area. System Action: Strobe continues sampling without DBRM attribution data. Strobe will not identify the DBRMs and SQL statements responsible for DB2 CPU activity in the Strobe Performance Profile. User Response: STR8440I Notify the Strobe system programmer. STRBDSNA: Sampling is active - SMO = ******************* Explanation: System Action: A Strobe for DB2 initialization informational message. Processing continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR8441E UNABLE TO LOCATE SYSTEM TABLE - SQL ATTRIBUTION DISABLED Explanation: Strobe cannot locate an internal table. System Action: Strobe continues sampling without attribution data. Strobe does not identify the DBRMs and SQL statements responsible for DB2 CPU activity in the Performance Profile. User Response: Notify the Strobe system programmer. STR8442W GETMAIN FAILURE IN STRBDSNA FOR block, SOME SQL ATTRIBUTION INFORMATION MAY BE MISSING Explanation: • • • • Strobe cannot obtain enough storage for attribution processing. block may be: SPI WORKAREA STS QIT QTK System Action: Strobe continues sampling, but some attribution information may be missing from the Performance Profile. User Response: programmer. STR8443W MISSING UNABLE TO OBTAIN block - SOME SQL ATTRIBUTION INFORMATION MAY BE Explanation: block may be: • • • • Increase the region size and resubmit the request. Notify the Strobe system Strobe cannot obtain attribution information from the area named in block. ADBLOCK SQL STMT SQL BUFFER CMD BUFFER 3-236 Strobe Messages Guide System Action: Strobe continues sampling, but some attribution information may be missing from the Performance Profile. User Response: If block is SQL STMT, resubmit the request. Otherwise, increase the region size and then resubmit the request. Notify the Strobe system programmer. STR8444W ABEND OCCURRED IN STROBE EXIT, SOME SQL ATTRIBUTION INFORMATION MAY BE MISSING Explanation: severe error. Strobe for DB2 cannot collect attribution data because it has encountered a System Action: Strobe continues sampling without DB2 attribution data. User Response: Notify the Strobe system programmer. STR8447W TCB = addr DB2 CAPTURE LOST DATA. BEGIN = time1 END = time2 TOTAL RECORDS LOST= nnnn, Explanation: The Strobe for DB2 buffer became full at time time1. Strobe emptied the buffer at time time2. Records lost, nnnn, reflects the count of the number of times an SQL call was made to DB2 and the data was not captured. The task control block (TCB) address addr is the task with the DB2 connection. System Action: Strobe continues processing; however, the counts and elapsed times reported for some SQL calls may be inaccurate. User Response: Specify a larger buffer for the capture function or increase the sampling rate to allow Strobe to empty the buffer more frequently. STR8449I ACQUIRED DATA SPACE FOR DB2 CAPTURE FUNCTION Explanation: Strobe for DB2 created a data space to support the DB2 capture function. System Action: Strobe continues processing. User Response: None required. STR8450I MAXIMUM SQL BUFFER STORAGE REACHED, SPECIFIED = nnn KB, USED = nnn KB, NEEDED = nnnnn BYTES Explanation: Strobe attempted to save a copy of an SQL statement, however it was unable to do so because that would cause the value specified by the MAXMEM parameter to be exceeded. The specified, used, and needed storage values are given. Strobe discards the SQL statement. System Action: missing. Strobe continues processing but SQL information may be inaccurate or User Response: Specify a larger value for the MAXMEM parameter. STR8451I THE DB2 CAPTURE FUNCTION HAS TERMINATED. REFER TO THE LOG DATA SET. Explanation: terminated. System Action: disabled. This message alerts you that the Strobe for DB2 SQL capture function has Strobe continues processing but the Strobe for DB2 capture function is User Response: View the log error messages describing the problem and follow the recommended response. STR8452E STRBDSNA unable to establish IFI environment Explanation: While initializing, Strobe was unable to establish a DB2 IFI Trace connection. System Action: disabled. Strobe continues processing, but the Strobe for DB2 SQL capture function is User Response: See message STR8712E for more information. STR8453E UNABLE TO OBTAIN BUFFER CONTROL AREA Explanation: Strobe for DB2’s attempt to acquire a work area during initialization of the capture facility failed. System Action: disabled. Strobe continues processing but the Strobe for DB2 SQL capture function is Messages Produced by Strobe User Response: STR8454E 3-237 Specify a larger region size for the job. UNABLE TO DETERMINE DB2 ATTACH FACILITY TYPE. DIAGCNAM = values Explanation: Although Strobe for DB2 recognized that a task control block was connected to DB2, the values values contained in the DB2 allied agent do not match a known type. System Action: disabled. Strobe continues processing but the Strobe for DB2 SQL capture function is User Response: Contact Compuware Customer Support. STR8455E UNABLE TO PLACE CAPTURE RETURN CODE FROM SSA-AGNT = rc Explanation: Strobe for DB2 received a non-zero return code, rc, from the Strobe SQL Agent, indicating an error condition. System Action: disabled. Strobe continues processing but the Strobe for DB2 SQL capture function is User Response: Contact Compuware Customer Support. STR8456E UNABLE TO OBTAIN SHADOW BUFFER. RETURN CODE FROM GETMAIN = rc Explanation: There is not enough available virtual storage to satisfy a request for a buffer equal in size to CAPTBUFF. The return code is rc. System Action: disabled. Strobe continues processing but the Strobe for DB2 SQL capture function is User Response: Either specify a larger region size or reduce the value for CAPTBUFF. STR8457E ERROR ON {GETMAIN | FREEMAIN} OF BUFFER CONTROL AREA. ERROR CODE = rc Explanation: The buffer control area has experienced either a GETMAIN or a FREEMAIN failure. The error code is rc. System Action: For a GETMAIN failure, Strobe capture processing terminates. For a FREEMAIN failure, Strobe continues processing with the original buffer control still allocated. User Response: If the failure is a GETMAIN failure, specify a larger region size. If the failure is a FREEMAIN failure, contact Compuware Customer Support. STR8458E RECORD CHAIN IN CAPTURE IS BROKEN. ATTEMPTING TO FIND NEXT DATA RECORD BY SCAN OF BUFFER. Explanation: An error occurred in the chaining of address and offset pointers to records being added to the buffer. The pointer to the next record from the last record added does not point to a valid record. Strobe attempts to locate the next sequential record in the buffer by scanning the entire buffer. System Action: If this happens more than five times during a measurement session, Strobe terminates capture processing. User Response: STR8459E RECORD. Contact Compuware Customer Support. RECORD CHAIN IN CAPTURE IS BROKEN. SETTING LAST REMOVED TO CURRENT Explanation: An error occurred in the chaining of address and offset pointers to records being added to the buffer. The pointer to the next record from the last record added does not point to a valid record. The Strobe attempt to locate the next sequential record in the buffer by scanning the entire buffer failed. System Action: Strobe continues processing but capture data may be lost, and counts and elapsed time may be inaccurate. User Response: Contact Compuware Customer Support. STR8460E DB2 CAPTURE ERROR HAS OCCURRED. COUNTS AND TIMES ARE PROBABLY INACCURATE. REFER TO THE LOG Explanation: occurred. An error condition that is not serious enough to stop capture processing 3-238 Strobe Messages Guide System Action: inaccurate. Strobe continues processing, but counts and times reported are probably User Response: Look in the Strobe log for error messages that describe the problem and follow the recommended action. STR8461I CAPTURE ERROR. CAPTURE POINT = OLD = old NEW = new SAMPLE = sample Explanation: The address in the DB2 attachment facility that Strobe needed for the Strobe for DB2 capture code to function is overlaid. • old is the address at which the Strobe for DB2 capture facility started • new is the address at which it now exists The sample number when Strobe detected this condition is given in sample. System Action: The Strobe for DB2 capture facility terminates. User Response: Contact Compuware Customer Support. STR8462E CAPTURE ERROR. CAPTURE FACILITY ERROR FLAG = {SUSPEND | ABENDED} Explanation: ABEND. The Strobe for DB2 capture facility encountered either a logical error or an • FLAG = SUSPEND indicates a logical error. • FLAG = ABENDED indicates that an ABEND occurred in the DB2 capture facility code System Action: The Strobe for DB2 capture facility terminates. User Response: Contact Compuware Customer Support. STR8463E CAPTURE FACILITY ERROR ON STORAGE OBTAIN REG 15 = r15, DYNAMIC SQL CANNOT BE PROCESSED Explanation: A storage OBTAIN failed. A buffer area that the DB2 capture facility requires to process dynamic SQL was not available. The value in register 15 upon return of the storage OBTAIN function is given in r15. System Action: SQL. The Strobe for DB2 capture facility continues to function, but only for static User Response: Increase the size of the extended private area available to the address space that Strobe is measuring. STR8464I CAPTURE ERROR. TRACE FUNCTION STORAGE OBTAIN FAILED. RETURN CODE = rc Explanation: Although you submitted the measurement with the DB2 flag setting specified as DEBUG, the storage required for the trace table was not available. The reason for the error is indicated by the return code rc. System Action: data. Strobe continues measuring, but the sample dataset will contain no trace User Response: Increase the size of the extended private area available to the address space that Strobe is measuring. STR8465I CAPTURE ERROR. TRACE FUNCTION TRACE TABLE CAPACITY EXCEEDED. TRACE INOPERATIVE Explanation: The volume of SQL activity in the address space that Strobe is measuring exceeds the capacity of the default trace table. System Action: Strobe continues measuring, but the trace function terminates. User Response: Contact Compuware Customer Support to obtain a program temporary fix (PTF) that will enlarge the trace table. STR8467I CAPTURE ERROR. CAPTURE FACILITY ERROR REASON = erc, SAMPLE = sample Explanation: The Strobe for DB2 capture facility was not able to recognize the control block structure in place in the DB2 attachment facility to locate the SQL. The error reason code, erc, indicates the location in the logic where the control block structure becomes unrecognizable. The sample number when Strobe detected the error is given in sample. System Action: Strobe issues this message. Messages Produced by Strobe User Response: STR8468E 3-239 None required. This information appears for diagnostic purposes only. CAPTURE ERROR. CAPTURE BUFFER TCB WORK AREA OUT OF ROOM Explanation: The Strobe for DB2 capture buffer TCB area is not large enough to hold all of the DB2 activity present in the address space. System Action: The Strobe for DB2 capture facility terminates. User Response: Contact Compuware Customer Support. STR8469E CAPTURE TERMINATING - INCOMPATIBLE WITH DSNTRACE ACTIVE Explanation: The DB2 trace facility DSNTRACE is active in the targeted address space. Strobe cannot measure accurately when DSNTRACE is active. System Action: The Strobe for DB2 capture facility terminates. User Response: Remove the DSNTRACE DD card from the targeted address space and rerun the Strobe measurement. STR8470I CAPTURE ENDS - MAXIMUM NUMBER OF TCBs ALLOWED TO BE MEASURED HAS BEEN EXCEEDED Explanation: Strobe’s limit of 400 Task Control Blocks (TCBs) for a DB2 measurement has been exceeded. Strobe for DB2 measurement ends. System Action: Strobe continues processing, without DB2 measurement. User Response: None required. STR8471I STRBDSNA text Explanation: A Strobe for DB2 initialization failed to communicate with the SQL agent capture process. The text may be any of the following: • • • • • • • SQL Agent (STRBSSA) rejected SSAREQ xxxxxx request SSAREQ Service Request xxxxxx ABENDed SSAREQ Service Request ABENDed with xxxxx DDF DETECTION FAILURE - NO DAB DDF DETECTION FAILURE - NO SYSTABLE DDF DETECTION FAILURE - NO STRBDSNS DDF DETECTION FAILURE - NO DB2 SUBSYS System Action: SQL capture processing does not occur. User Response: Contact Compuware Customer Support. STR8472E SQL CAPTURE IS TERMINATED FOR THIS MEASUREMENT - REASON = xx Explanation: When attempting to initialize SQL capture, flush an SQL statement from the capture data space, or terminate SQL capture, Strobe for DB2 capture processing encountered an error that caused capture processing to be terminated for the measurement. System Action: When attempting to initialize SQL capture, flush an SQL statement from the capture data space, or terminate SQL capture, Strobe for DB2 capture processing encountered an error that caused capture processing to be terminated for the measurement. Values for the reason code xx are as follows: • • • • • • • • • • • • • 01 02 03 04 11 12 13 14 15 16 17 32 33 - UNABLE TO CREATE THE CAPTURE DATA SPACE UNABLE TO OBTAIN STORAGE FOR THE SHADOW BUFFER UNABLE TO OBTAIN STORAGE FOR THE HOLDING BUFFER REQUEST TO SUBSCRIBE THE MEASUREMENT TO THE SSA FAILED NO ALET DESIGNATED FOR THE CAPTURE DATA SPACE NO START-ADDRESS DESIGNATED FOR THE CAPTURE DATA SPACE NO ADDRESS DESIGNATED FOR THE SHADOW BUFFER INVALID EYECATCHER IN THE INTDATA STATEMENT-HEADER INTDATA HEADER INDICATES THAT STATEMENT IS ALREADY FLUSHED INTDATA HEADER INDICATES ZERO DATA LENGTH INTDATA HEADER INDICATES EXCESSIVE DATA LENGTH UNABLE TO RELEASE SHADOW-BUFFER STORAGE UNABLE TO RELEASE HOLDING-BUFFER STORAGE System Action: Strobe for DB2 capture processing terminates for this measurement. Measurement processing continues. 3-240 Strobe Messages Guide User Response: STR8473E Contact Compuware Customer Support. ERRONEOUS STATEMENT COUNT IN CAPTURE DATA SPACE HEADER Explanation: When Strobe for DB2 invoked the flush routine to flush the SQL data from the capture data space, the count of the number of SQL statements in the data space was zero. System Action: Strobe for DB2 flush processing indicates that the data space has been flushed, thereby making it available to receive SQL statements that may be captured subsequently. User Response: Contact Compuware Customer Support. STR8475E CONVERSION OF SQL TEXT TO EBCDIC FAILED - RC (xxxxxxxx | yyyyyyyy)  VER=n, TNQ=nn, SRC=nnnn, TRG=nnnnn, DDA=nnnnnnn, TBF=nnnnnnn, WBF=nnnnnnn Explanation: Unicode code conversion service failed with xxxxxxxx return and yyyyyyyy reason codes. Therefore, Strobe was unable to convert the text of this SQL statement to EBCDIC. Strobe supplied Unicode code conversion services with the following information: • • • • • VER: Version number of the Unicode conversion services used TNQ: Technical-search order for the source and target CCSIDs SRC: CCSID of the SQL text in the input buffer TRG: CCSID of the SQL text in the output buffer DDA: Decimal size in bytes of the dynamic data area. This is the working storage area used by Unicode conversion services. • TBF: Decimal size in bytes of the target buffer. Unicode conversion services uses this buffer to store the converted results. • WBF: Decimal size in bytes of the work buffer. Unicode conversion services uses this buffer to store intermediate results. System Action: Strobe failed to convert this particular SQL statement, but will attempt to convert the text of subsequent SQL statements to EBCDIC. User Response: Determine the reason for the failure by finding the return and reason codes in the IBM Support for Unicode manual. If you do not understand the reason code associated with the return code, contact Compuware Customer Support with the information that Strobe supplied to Unicode conversion services for this SQL statement. STR8476W LOAD MODULE xxxxxxxx NOT AVAILABLE - RC=yyyyyyyy, RSN=zzzzzzzz TARGET CCSID 37 USED AS DEFAULT. Explanation: Load module xxxxxxxx (usually DSNHDECP) was not loaded. This module was not found in an APF-authorized concatenation or in the linklist concatenation. System Action: Latin-1, USA). Incoming SQL text from the application is converted to CCSID 37 (EBCDIC User Response: If code page 37 is not acceptable for your site, update the DSNHDECP load module. Consult the IBM DB2 installation manual on updating DSNHDECP. See the IBM MVS System Codes manual for an explanation of the yyyyyyyy return and zzzzzzzz reason codes returned by the LOAD macro. STR8477W APPLICATION REQUESTING DATA FROM A REMOTE LOCATION location, SQL ATTRIBUTION INFORMATION MAY BE MISSING. Explanation: Strobe for DB2 cannot collect SQL attribution data because it has encountered an application requesting data from the remote location location. System Action: Strobe continues sampling without DB2 attribution data. User Response: Notify the Strobe system programmer. STR8478W APPLICATION SENDING DATA TO A REMOTE LOCATION, SQL ATTRIBUTION INFORMATION MAY BE MISSING. Explanation: Strobe for DB2 cannot collect SQL attribution data because it has encountered an application requesting data from a remote location. System Action: Strobe continues sampling without DB2 attribution data. User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR8505E 3-241 DML-SEQUENCE NUMBER NOT AVAILABLE - DML ATTRIBUTION INCOMPLETE Explanation: Strobe could not locate the DML-sequence number in the user program. The user program was not compiled with the CA-IDMS debug protocol. System Action: Strobe continues sampling, but attribution data will be incomplete. User Response: Recompile the program using the CA-IDMS debug protocol option and resubmit the request. STR8506E GETMAIN FAILURE - ADS/O ATTRIBUTION MODULE STRBADXX DISABLED Explanation: The ADS/O attribution module STRBADXX cannot obtain sufficient storage for its work area. System Action: Strobe disables ADS/O attribution. User Response: Increase the region size and resubmit the request. STR8507E ADS/O ATTRIBUTION DISABLED Explanation: System Action: The ADS/O attribution module failed during initialization. Strobe continues sampling but will not attribute any ADS/O dialog activity. User Response: Refer to the preceding error message in the Strobe log for the specific reason for the ADS/O attributor module failure. STR8508E GETMAIN FAILURE - SQL ATTRIBUTION MODULE program name DISABLED Explanation: Strobe was unable to obtain virtual storage to locate and load the CA-IDMS release-specific SQL data collection module. System Action: Strobe disables CA-IDMS attribution. User Response: Increase the region size and resubmit the request. STR8509E SQL ATTRIBUTION MODULE program name NOT FOUND Explanation: Strobe was unable to locate and load the CA-IDMS release-specific SQL data collection module. System Action: Strobe continues sampling, but will not attribute any CA-IDMS SQL activity. User Response: failure. Examine the preceding error message in the Strobe log for the cause of this STR8510C REPORTED CA-IDMS IS NOT ACTIVE. TRANSACTION COUNTS AND SERVICE TIMES ARE NOT Explanation: CA-IDMS has either experienced an ABEND or was terminated before the Strobe measurement session completed. System Action: Strobe will produce a Performance Profile but will not report CA-IDMS transaction counts and service times. User Response: Resubmit the Strobe measurement request and then restart CA-IDMS. To end the Strobe measurement session, issue a SEND,QUIT command before terminating CA-IDMS. STR8600E PARMLIB STROBE NATURAL CONFIGURATION PARAMETERS NOT SUPPLIED IN STROBE Explanation: Strobe could not invoke Strobe for Natural because it could not find the Natural configuration parameters in the PARMLIB. System Action: Strobe continues sampling without Natural attribution data. User Response: Notify the Strobe system programmer. STR8700E TCMNAME PARM VALUE parm IS NOT A VALID THREAD CONTROL BLOCK Explanation: In the Strobe for Adabas/Natural configurations module, STRBANCM, the TCMNAME = parameter value parm for the Natural/CICS region being measured is not the name of a valid Natural Thread control block. System Action: Strobe continues sampling without Natural attribution data. 3-242 Strobe Messages Guide User Response: Specify the valid Thread control block module name of the Natural/CICS region being measured in the Strobe for Adabas/Natural configurations module, STRBANCM. Reinstall the configurations module as described in the Strobe Installation and Customization Guide. STR8701C ATTRIBUTION SUPPRESSED FOR NATURAL PROGRAM progname - COMPILED date time RECOMPILED compdate comptime Explanation: Strobe has suppressed attribution for Natural program progname because this program was recompiled during the Strobe measurement session. The message gives the date and time the program was originally compiled (date and time) and the date and time the program was recompiled (compdate and comptime). System Action: Strobe stops collecting attribution data for the program that was recompiled. User Response: Rerun the measurement session. Do not recompile the target Natural program during a Strobe measurement session. STR8702E STROBE DOES NOT SUPPORT MEASUREMENT OF NATURAL UNDER ADABAS Explanation: You specified NATURAL=Y on the Strobe - Data Collectors panel when measuring an Adabas region. Strobe does not support attribution of Natural triggers and stored procedures running in an Adabas region. System Action: Strobe continues processing but does not collect Natural or Adabas attribution data. User Response: Do not specify NATURAL=Y on the Strobe - Data Collectors panel when measuring an Adabas region. STR8710E STRBDSNA: INITR command failed,RC=XX,RS=XXX Explanation: The DB2 Attributor SSAREQ0 request to initialize the SQL capture subtask for the measured address space failed with the return code and reason code shown in the message. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. The Measurement Session Data report will be incomplete. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8711E STRBDSNA: INITM command failed,RC=XX,RS=XXX Explanation: The DB2 Attributor SSAREQ0 request to initialize the SQL capture subtask for a non-DDF Address Space failed with the return code and reason code shown in the message. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. The Measurement Session Data report will be incomplete. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8712E STRBDSNA: STAM command failed,RC=XX,RS=XXX Explanation: The DB2 Attributor SSAREQ0 request to the SQL capture subtask to start the IFICID collection failed with the return code and reason code shown in the message. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. The Measurement Session Data report will be incomplete. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8713E STRBDSNA: IFI Environment invalid at close SDS Explanation: SDS time. The DB2 Attributor found an invalid or not present IFI environment at Close System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Notify the Strobe system programmer. Messages Produced by Strobe STR8714I 3-243 STRBDSNA: IFI Flushing at Close SDS started. Explanation: The DB2 Attributor has started the final flushing process of the SQL attribution samples, associated to the closing of the Strobe SDS dataset. System Action: None. User Response: No action is required. This is an informational message. STR8715I STRBDSNA: IFI Command FLSH being issued. Explanation: The DB2 Attributor has issued an SSAREQ FLSH command as part of the flushing process of the SQL attribution samples, associated to the closing of the Strobe SDS dataset. System Action: None. User Response: No action is required. This is an informational message. STR8716E STRBDSNA: IFI Flushing at close SDS failed,RC=XX,RS=XXX Explanation: The SSAREQ FLSH command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CLOSE SDS time, failed with the return code and reason code shown in the message. See “Strobe Programmed Terminations” on page 5-1 for RC and RS codes. System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8717E STRBDSNA: IFI Flushing Z6T14 write failed,RC=XX,RS=XXXX Explanation: The $DSN1 FSHT14 command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CLOSE SDS time, failed with the return code and reason code shown in the message. See “Strobe Programmed Terminations” on page 5-1 for RC and RS codes. System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8718E STRBDSNA: IFI Flushing SMO cleanup failed,RC=XX,RS=XXXX Explanation: The $DSN1 QDEL command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CLOSE SDS time, failed with the return code and reason code shown in the message. See “Strobe Programmed Terminations” on page 5-1 for RC and RS codes. System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8719I STRBDSNA: IFI Command FLSH completed. Explanation: The SSAREQ FLSH command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CLOSE SDS time, has been completed successfully. System Action: None. User Response: No action is required. This is an informational message. STR8720I STRBDSNA: IFI Command MAKZ being issued. Explanation: The DB2 Attributor has issued an SSAREQ MAKZ command as part of the flushing process of the SQL attribution samples, associated to the closing of the Strobe SDS dataset. System Action: None. 3-244 Strobe Messages Guide User Response: STR8721E No action is required. This is an informational message. STRBDSNA: IFI Command MAKZ failed,RC=XX,RS=XXX. Explanation: The SSAREQ MAKZ command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples, failed with the return code and reason code shown in the message. See “Strobe Programmed Terminations” on page 5-1 for RC and RS codes. System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8722I STRBDSNA: IFI Command MAKZ completed. Explanation: The SSAREQ MAKZ command issued by the DB2 Attibutor as part of the flushing process of the SQL attribution samples has completed successfully. System Action: None. User Response: No action is required. This is an informational message. STR8723E STRBDSNA: IFI Write ZTYPE records failed,RC=XX,RS=XXX Explanation: The $DSN1 ZWRIT command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples, failed with the return code and reason code shown in the message. System Action: The DB2 Attributor terminates the Close SDS processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8724I STRBDSNA: IFI Environment terminating. Explanation: The DB2 Attributor has issued an SSAREQ TERM command as part of the flushing process of the SQL attribution samples, associated to the closing of the Strobe SDS dataset. System Action: None. User Response: No action is required. This is an informational message. STR8725I STRBDSNA: IFI Flushing at CLOSE SDS complete Explanation: The SSAREQ TERM command issued by the DB2 Attibutor as part of the flushing process of the SQL attribution samples has completed successfully. System Action: None. User Response: No action is required. This is an informational message. STR8726I STRBDSNA: IFI Flushing at CPU IDENT time enabled Explanation: The DB2 Attributor issues this message upon receiving the first CPU Identify Call from the Strobe driver to indicate that flushing processing at CPU Identify time has been activated. System Action: None. User Response: No action is required. This is an informational message. STR8727I STRBDSNA: IFI Flushing at CPU IDENT suspended. Explanation: The DB2 Attributor issues this message upon receiving a signal from the SQL Agent the first IFCID for the measured address space has been captured. This message indicates that flushing processing at CPU Identify time has been suspended. System Action: None. User Response: No action is required. This is an informational message. Messages Produced by Strobe STR8728E 3-245 STRBDSNA: IFI Flushing at CPU IDENT failed,RC=XX,RS=XXX Explanation: The SSAREQ FLSH command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CPU IDENT time, failed with the return code and reason code shown in the message. System Action: The DB2 Attributor terminates the CPU IDENT processing. Strobe continues sampling without DB2 collection. The Measurement Session Data report will be incomplete. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8729E STRBDSNA: IFI Flushing Z6T14 write failed,RC=XX,RS=XXXX Explanation: The $DSN1 FSHT14 command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CPU IDENT time, failed with the return code and reason code shown in the message. System Action: The DB2 Attributor terminates the CPU IDENT processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8730E STRBDSNA: IFI Flushing SMO cleanup failed,RC=XX,RS=XXXX Explanation: The $DSN1 QDEL command, issued by the DB2 Attributor as part of the flushing process of the SQL attribution samples at CPU IDENT time, failed with the return code and reason code shown in the message. System Action: The DB2 Attributor terminates the CPU IDENT processing. User Response: Collect the meaning/action for the return code and reason code combination from “Strobe Programmed Terminations” on page 5-1 and notify the Strobe system programmer. STR8731E STRBDSNA: Check Strobe environment failure - no MSCB Explanation: The DB2 Attributor was unable to find internal Strobe MSCB Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8732E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - no CPWRTBL Explanation: Block. The DB2 Attributor was unable to find internal Strobe CPWRTBL Control System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8733E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - no SAG. Explanation: The DB2 Attributor was unable to find internal Strobe SAG Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8734E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - invalid SAG Explanation: The DB2 Attributor has detected an invalid internal Strobe SAG Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8735E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - no SAL. Explanation: The DB2 Attributor was unable to find internal Strobe SAL Control Block. 3-246 Strobe Messages Guide System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8736E Notify the Strobe system programmer. STRBDSNA: DDF detection failure - no DAB. Explanation: The DB2 Attributor was unable to find internal Strobe DAB Control Block for a DB2 DDF Strobe measurement. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8737I Notify the Strobe system programmer. STRBDSNA: DDF measurement detected. Explanation: The DB2 Attributor has detected a DB2 DDF measurement. System Action: None. User Response: No action is required. This is an informational message. STR8738E STRBDSNA: Check Strobe environment failure - no #IFT. Explanation: The DB2 Attributor was unable to find internal Strobe #IFT Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8739E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - no DFT. Explanation: The DB2 Attributor was unable to find internal Strobe DFT Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8740E Notify the Strobe system programmer. STRBDSNA: Invalid Strobe environment detected. Explanation: The DB2 Attributor was unable to find a required internal Strobe Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8741E Notify the Strobe system programmer. STRBDSNA: Check Strobe environment failure - no #SSB. Explanation: The DB2 Attributor was unable to find internal Strobe SSB Control Block. System Action: The DB2 Attributor is disabled. Strobe continues sampling without collecting attribution. User Response: STR8742I Notify the Strobe system programmer. STRBDSNA: SQL activity has been detected. Explanation: The DB2 Attributor has detected SQL activity generated by the User Application being measured. System Action: Strobe continues sampling without collecting attribution. User Response: No action is required.This is an informational message. STR8743I STRBDSNA: Unable to get DB2 Release info - xxxxxxxxxxxxxxxxxx Explanation: The DB2 Attributor was unable to determine the DB2 Version and Release information for a DDF measurement. System Action: Strobe measurement is terminated. User Response: No action is required. This is an informational message. Messages Produced by Strobe STR8744I 3-247 STRBDSNA: DB2 V### not supported. No SQL Attribution done for DB2: #### Explanation: The DB2 Attributor has detected SQL activity generated for a DB2 subsystem Version 8 or lower. System Action: Local: Strobe continues sampling without SQL attribution. DDF: Strobe continues without sampling and without SQL attribution. User Response: STR8745I No action is required. This is an informational message. STRBDSNA: Parameter SSA=No is in effect. SQL Attribution not possible. Explanation: The Strobe Parameter member contains SSA=NO. This causes no Strobe SQL Agent to be active, so SQL cannot be detected for attribution. System Action: Measurement continues without SQL attribution. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR8746I STRBDSNA: xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx(NNNNN) Explanation: Strobe DB2 SQL Attributor issues this message to display the reason for the IFI Trace activation or inactivation, where: xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx shows the reason of the activation/inactivation. Valid values are: • Active per User Request • Disable per User Request • Disable per Invalid Capture Options. NNNNN shows the combination of internal flags that lead to the IFI trace activation or inactivation. This message is issued to assist Compuware Customer Support in problem determination. System Action: The Strobe DB2 SQL Attributor continues processing. User Response: No action is required. This is an informational message for the use of Compuware Customer Support only. STR8747I STRBDSNA: TERM call received from Attribution driver. Explanation: Strobe for DB2 termination message. System Action: Termination continues. User Response: None required. This is an informational message for the use of Compuware Customer Support only. STR8748E STRBDSNA: Strobe Hook SSAREQ command failed. Attribution not possible Explanation: A Strobe SSAREQ command to initiate the Strobe IFI Collector failed. The SSAREQ is issued by the Strobe DB2 Hook module. System Action: The Strobe SQL Attributor (STRBDSNA) will issue message STR8748I and the DB2 Attributor is disabled. Strobe continues sampling without DB2 Collection. The Measurement Session Data report will be incomplete. User Response: Check the Strobe STRSSA Address Space logs looking for DB2 messages associated with the DB2 -STA TRACE command failure or other error messages issued by the Strobe IFI Collector module STRBFIFR. STR8749I STRBDSNA: DB2 IFI Trace requested: xxxxxxxxxxxxxxxxxxxxxx Explanation: This is an informational message that shows the value coded for the Strobe "IFITRACE" parameter xxxxxxxxxxxxxxxxxxxxxxx possible values are: – Accounting – Performance – Accounting and Performance. System Action: The Strobe SQL Attributor (STRBDSNA) will issue message STR8749I. User Response: No user action is required. 3-248 Strobe Messages Guide STR8750I STRBDSNA: Collect DB2 Predicate Data Active for Dynamic SQL Literals Explanation: This is an informational message indicating that the value for the Strobe COLLECT_DB2_PRED_DATA parameter is ENABLE and the Collect DB2 Predicate Data Literals option was selected. System Action: The Strobe SQL Attributor (STRBDSNA) will issue message STR8750I. User Response: No user action is required. STR8751I STRBDSNA: DB2 Filtering forced on when Collect DB2 Predicate Data Active Explanation: This is an informational message indicating that DB2 filtering must be turned on when the Strobe PARMLIB value for COLLECT_DB2_PRED_DATA is ENABLE and the Collect DB2 Predicate Data Literals option was selected. System Action: The Strobe SQL Attributor (STRBDSNA) will issue message STR8751I. User Response: No user action is required. STR8752I STRBDSNA: PARMLIB COLLECT_DB2_PRED_DATA is Disabled; Request Option ignored Explanation: This is an informational message indicating that the Collect DB2 Predicated Data Literals option was requested, but the current Strobe PARMLIB value for COLLECT_DB2_PRED_DATA is DISABLE. System Action: The Strobe SQL Attributor (STRBDSNA) will issue message STR8752I. User Response: No user action is required. STR8753I STRBDSNA: Continuing measurement without DB2 Collection Explanation: The DB2 Attributor SSAREQ0 request to initialize the SQL capture subtask for the measured address space failed with the return code and reason code shown in previous message. System Action: The DB2 Attributor is disabled. Strobe continues sampling without DB2 collection. The Measurement Session Data report will be incomplete. User Response: The DB2 Attributor is disabled. Strobe continues sampling without DB2 collection. The Measurement Session Data report will be incomplete. Messages Returned by Strobe Advisor STR9001W STROBE ADVISOR IS AVAILABLE FOR STROBE 4.4 AND LATER Explanation: The Strobe sample dataset being processed by Reporter was created by a release of Strobe earlier than 4.4. System Action: The Strobe performance profile generated by Reporter will not contain the Strobe Advisor summary report. User Response: If the sample dataset being processed originated from a recently measured application, remeasure the application using a current version of Strobe in order to obtain the Strobe Advisor summary report. STR9002W STROBE ADVISOR WAS DISABLED BY PARAMETER NOSBARPT Explanation: Reporter parameter NOSBARPT was specified. System Action: The Strobe performance profile generated by Reporter will not contain the Strobe Advisor summary report. User Response: Remove parameter NOSBARPT in order to obtain the Strobe Advisor summary report. STR9099E UNEXPECTED RETURN CODE FROM STROBE ADVISOR - Explanation: Reporter received an unexpected return code from Strobe Advisor. System Action: The Strobe performance profile generated by Reporter may or may not contain the Strobe Advisor summary report. If it does, the report may or may not be valid. User Response: Contact Compuware Customer Support. Messages Produced by Strobe STR9110E Unable to open temporary XML file Explanation: Strobe's Advisor was unable to open the temporary XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9111E Unable to close temporary XML file Explanation: Strobe's Advisor was unable to close the temporary XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9112E Unable to read from temporary XML file Explanation: Strobe's Advisor was unable to read from the temporary XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9113E Unable to write to temporary XML file Explanation: Strobe's Advisor was unable to write to the temporary XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9114E Unable to open permanent XML file Explanation: Strobe's Advisor was unable to open the permanent XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9115E Unable to close permanent XML file Explanation: Strobe's Advisor was unable to close the permanent XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9116E Unable to write to permanent XML file Explanation: Strobe's Advisor was unable to write to the permanent XML file. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact Compuware Customer Support. STR9118E 3-249 Unable to obtain PTF information for xxxxxxxx Explanation: Strobe's Advisor was unable to obtain the PTF information for the specified Strobe module. System Action: Strobe's Advisor terminates and complete advice cannot be provided. User Response: Contact your Strobe system programmer. STR9130E Cannot obtain storage for Catalog Access Explanation: Strobe's DB2 Advisor cannot obtain enough storage to perform DB2 calls against the DB2 Catalog. System Action: provided. System Action: Strobe's DB2 Advisor terminates and DB2 advice will not be User Response: Increase the region size and resubmit the request. STR9131E Cannot obtain storage for DCB EZDB2F2 Explanation: Strobe's DB2 Advisor cannot obtain enough storage to hold the SQL statement information to be analyzed. 3-250 Strobe Messages Guide System Action: Strobe's DB2 Advisor terminates and DB2 advice will not be provided. User Response: Increase the region size and resubmit the request. STR9132W Cannot load STRZD2SQ Explanation: library. Strobe's DB2 Advisor could not find the module STRZD2SQ in the Strobe load System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e., available index information and utility recommendations. User Response: STR9133W Notify the Strobe system programmer. No SQLAF Explain Information Available Explanation: DB2 Advisor. The SQLAF Explain information was not available for processing by Strobe's System Action: Strobe's DB2 Advisor continues analysis without the Explain information from the SQLAF. User Response: STR9134E Resolve any issues from SQLAF and resubmit the request. EZDB2F1 Row failed validation Explanation: Reporter. Strobe's DB2 Advisor was passed data in an unexpected format from Strobe's System Action: Strobe's DB2 Advisor terminates and DB2 advice will not be provided. User Response: Contact Compuware Customer Support. STR9135W Unknown Record Type found in EZDB2F2 - Record will be bypassed Explanation: Strobe's DB2 Advisor was passed data in an unexpected format from SQLAF. System Action: the SQLAF. Strobe's DB2 Advisor continues analysis with incomplete information from User Response: Resolve any issues from SQLAF and resubmit the request. STR9136W Cannot obtain storage for EZDB2F2- Results may be incomplete Explanation: information. Strobe's DB2 Advisor cannot obtain enough storage to hold SQLAF System Action: SQLAF. Strobe's DB2 Advisor continues analysis without information from the User Response: Increase the region size and resubmit the request. STR9137W details 20+ TS Scans were detected on an SQL Statement - Refer to Explain for complete Explanation: Strobe's DB2 Advisor found a statement that contained more than 20 tablespace scans. Only the first 20 will be highlighted on the Strobe DB2 Advisor Explain Summary. For details on the remaining sorts, please refer to the Explain output. System Action: Strobe's DB2 Advisor continues processing. User Response: None Required. STR9138W 20+ Sorts were detected on an SQL Statement - Refer to Explain for complete details Explanation: Strobe's DB2 Advisor found a statement that contained more than 20 sorts. Only the first 20 will be highlighted on the Strobe DB2 Advisor Explain Summary. For details on the remaining sorts, please refer to the Explain output. System Action: Strobe's DB2 Advisor continues processing. User Response: None Required. STR9141W Cannot obtain storage - TS utility recommendations may be incomplete Explanation: Strobe's DB2 Advisor cannot obtain enough storage to hold tablespace utility recommendations. Messages Produced by Strobe 3-251 System Action: Strobe's DB2 Advisor continues analysis with missing information regarding DB2 Tablespace utility recommendations. User Response: STR9142W Increase the region size and resubmit the request. Cannot obtain storage - IX utility recommendations may be incomplete Explanation: Strobe's DB2 Advisor cannot obtain enough storage to hold index utility recommendations. System Action: Strobe's DB2 Advisor continues analysis with missing information regarding DB2 Index utility recommendations. User Response: STR9143W Increase the region size and resubmit the request. Strobe's DB2 Advisor is unable to connect to DB2 Explanation: Strobe's DB2 Advisor could not complete the connection to DB2. System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e., available index information and utility recommendations. User Response: STR9144W Bind Please review Strobe installation instructions. The DBRM (STDFIFM) for Strobe's DB2 Advisor has not been bound - Please execute Explanation: Strobe's DB2 Advisor could not complete the connection to DB2. System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e., available index information and utility recommendations. User Response: Please review Strobe installation instructions regarding the bind requirements for Strobe DB2. STR9145W Grant Public access has not been granted to Strobe's Plan (STRANANA) - Please execute Explanation: Strobe's DB2 Advisor could not complete the connection to DB2. System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e. available index information and utility recommendations. User Response: Please review Strobe installation instructions regarding the grant requirements for Strobe DB2. STR9146W Strobe's DB2 Advisor received an invalid SQLCODE (nnnnnn) Explanation: Strobe's DB2 Advisor could not complete the DB2 request. System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e., available index information and utility recommendations. User Response: Please review Strobe installation instructions regarding the requirements for Strobe DB2. Contact your Strobe system programmer. STR9147W DB2 Catalog recommendations will not be provided Explanation: See corresponding STR9143W, STR9144W, STR9145W, or STR9146W for additional information. System Action: Strobe's DB2 Advisor continues analysis without information from the DB2 catalog; i.e., available index information and utility recommendations. User Response: STR9150W See corresponding message. Strobe's DB2 Advisor Max IX Length Explanation: Strobe's DB2 Advisor found more than 30,000 charactersf index information (index names, key column names, and index on expression information) for the SQL statements being analyzed. System Action: Strobe's DB2 Advisor discontinues index retrieval. User Response: None required. 3-252 Strobe Messages Guide STR9190W LE Options information will not be provided Explanation: An error occurred while processing the LE options. System Action: Strobe Advisor continues analysis without the LE options information. This information will not appear in the profile. User Response: In the case of a serious error, messages STR9195E and STR9196E may appear in conjunction with this message. Refer to those messages for additional information. STR9191W Strobe Advisor data may be incomplete or unavailable Explanation: profile. An error occurred while processing or writing Strobe Advisor data to the System Action: Strobe Advisor stops analysis at the point of the error and Strobe Advisor information may be incomplete in the profile. User Response: In the case of a serious error, messages STR9195E and STR9196E may appear in conjunction with this message. Refer to those messages for additional information. STR9192W Strobe Advisor's DB2 data may be incomplete or unavailable Explanation: An error occurred while processing DB2 information. System Action: Strobe Advisor continues analysis without the DB2 information. This information may not appear in the profile or could be incomplete User Response: In the case of a serious error, messages STR9195E and STR9196E may appear in conjunction with this message. Refer to those messages for additional information. STR9195E Error detected in xxxxxxxx at offset yyyyyyyy, ABEND: Szzz Uzzzz REASON: zzzzzzzz Explanation: A serious error occurred within Strobe Advisor or while Strobe Advisor was in control. The specific module and offset of the error are provided along with the ABEND and Reason codes. System Action: Strobe Advisor terminates the related processing and attempts to continue. Some or all Strobe Advisor information may be unavailable in the profile. User Response: Contact Compuware Customer Support. See STR9196E for additional information related to the error. STR9196E Strobe module xxxxxxxx (vvrrmm/nnnnnn/ddmmmyy/hh.mm) was in control at the time of error Explanation: This message is a continuation of information related to the error detailed in STR9195E. The Strobe module that detected the error is provided along with the version, PTF level, and compile date and time. System Action: Strobe Advisor terminates the related processing and attempts to continue. Some or all Strobe Advisor information may be unavailable in the profile. User Response: Contact Compuware Customer Support. See STR9195E for additional information related to the error. STR9197W incomplete. ED2 Unable to execute DB2 .DIS BUFFERPOOL, Reason: XXXXXXXX. BP data will be Explanation: An unexpected error occurred when the DB2 command -DIS BUFFERPOOL was executed. Use the Error Code XXXXXXXX and refer to your DB2 manual. System Action: The buffer pool data on the DB2 SQL Activity Summary will be incomplete. User Response: Refer to your DB2 manuals to determine the cause of the failure. Contact Compuware Customer Support if assistance is needed. Messages Returned by Strobe SQL Analysis Strobe SQL analysis returns the following messages. Messages Produced by Strobe STR9501I 3-253 PLAN_TABLE CREATED FOR AUTHORIZATION ID authID Explanation: Strobe SQL analysis created an instance of PLAN_TABLE for authorization ID authID during Profile creation. System Action: Processing continues. User Response: None required. STR9502E GENERATION OF QUERY NUMBER FAILED, SEE PRECEDING MESSAGE(S) Explanation: Strobe SQL analysis cannot generate a unique query number for an SQL statement it processed. System Action: Strobe SQL analysis attempts to process that statement again. User Response: Refer to preceding messages for additional information. STR9503E NO UNIQUE QUERY NUMBERS ARE AVAILABLE Explanation: Strobe SQL analysis cannot generate a unique query number for SQL statements it processes because all possible unique query numbers in PLAN_TABLE are used. System Action: Processing for the current Profile stops. User Response: Delete rows from PLAN_TABLE and resubmit the Profile creation request. STR9504E MEMORY ALLOCATION FAILED Explanation: System Action: Strobe SQL analysis cannot allocate sufficient virtual storage. Processing for the current Profile/statement stops. User Response: If you were creating a Performance Profile including SQL Analysis information when you received this message, try reducing the number of SQL statements that are processed and then recreate the Profile. Several parameters can reduce the number of SQL statements processed: • TOTAL CPU PERCENT or TOP N USERS • TOTAL WAIT TIME or TOP N WAIT • DBRM NAME For information on how to specify these parameters, see the Strobe User Guide. In addition, if you are using SQL Analysis with DDF reports, you can limit the number of SQL statements processed by SQL Analysis by using DDF thresholds and filters. For more information, see the Strobe for DB2 section in the options manual. If you were not creating a Performance Profile including SQL Analysis information, increase your region size. STR9505E SQL STATEMENT PARSE NOT COMPLETED, SEE PRECEDING MESSAGE(S) Explanation: Strobe SQL analysis has encountered an error while processing a SQL statement. Either Strobe SQL analysis encountered an internal error or the SQL verb is not processed by Strobe SQL analysis. System Action: Processing for the current SQL statement stops. User Response: Refer to preceding messages for additional information. STR9506I THE FOLLOWING STATEMENT IS NOT DML sqlstemtext Explanation: The SQL statement text is not a valid DML statement. System Action: Processing for the current SQL statement stops. Processing continues with the next statement. User Response: None required. Only DML SQL statements (that manipulate data such as SELECT, INSERT, UPDATE and DELETE) are processed by Strobe SQL analysis. STR9507E ERROR OCCURRED DURING ACCESS OF PLAN_TABLE, SEE PRECEDING MESSAGE(S) Explanation: An attempt by Strobe SQL analysis during Profile creation either to create an instance of PLAN_TABLE for the resolved authorization ID or to locate an instance of PLAN_TABLE when using existing PLAN_TABLE rows failed. 3-254 Strobe Messages Guide System Action: Processing for the current Profile stops. User Response: If the Profile request specified use of existing PLAN_TABLE rows, ensure that an instance of PLAN_TABLE exists for the specified authorization ID. Otherwise, refer to preceding messages for additional information. STR9508E RETRIEVAL OF TABLE TYPE FOR tablename FAILED Explanation: System Action: An attempt to retrieve the table type for table tablename failed. Processing for the current SQL statement stops. User Response: Ensure tablename identifies an existing table in the catalog of the DB2 subsystem against which Strobe SQL analysis connected. STR9509E RETRIEVAL OF TEXT FOR ALIAS aliasname FAILED, SEE PRECEDING MESSAGE(S) Explanation: An attempt to retrieve the text for alias aliasname failed. System Action: Processing for the current SQL statement stops. User Response: Refer to preceding messages for additional information. STR9510E RETRIEVAL OF TEXT FOR VIEW viewname FAILED, SEE PRECEDING MESSAGE(S) Explanation: An attempt to retrieve the SQL statement text for view viewname failed. System Action: Processing for the current SQL statement stops. User Response: Refer to preceding messages for additional information. STR9511E PROCESSING OF CAF SERVICE service FAILED: RC = rc RE = X're' Explanation: A DB2 Call Attach Facility error occurred processing service request service with return code rc and reason code re. Refer to accompanying message STR9512I, STR9513I, or STR9514I for additional information. System Action: Processing for the current file stops. User Response: Notify the Strobe system programmer of the problem. STR9512I CAF CONNECT PARAMETERS: SSID: (subsystemID) Explanation: subsystemID identifies the DB2 subsystem to which Strobe SQL analysis attempted to connect through the DB2 Call Attach Facility. If subsystemID is blank, the sample dataset was probably created with a version of Strobe prior to Version 1 Release 9.2. System Action: Processing for the current file stops User Response: Specify the ID of the subsystem in the DB2 SUBSYSTEM field of the Strobe SQL Analysis Feature Report Settings panel. If subsystemID is not blank, ensure the subsystem is available, then resubmit the Profile creation request. Refer to accompanying message STR9511E for additional information. Notify the Strobe system programmer of the problem. STR9513I CAF OPEN PARAMETERS: SSID: (subsystemID) PLAN: (planname) Explanation: subsystemID identifies the DB2 subsystem with which Strobe SQL analysis attempted to open plan planname through the DB2 Call Attach Facility. planname should be STRANANA, the application plan created during installation of Strobe SQL analysis. System Action: Processing for the current profile stops. User Response: If subsystemID is available, ensure that planname exists and that the resolved authorization ID has EXECUTE privilege for planname. Then resubmit the Profile creation request. Refer to accompanying message STR9511E for additional information. Notify the Strobe system programmer of the problem. Messages Produced by Strobe STR9514I 3-255 CAF CLOSE PARAMETERS: TERM: (termoption) Explanation: termoption identifies the option used to terminate the thread created previously with the open service request through the DB2 Call Attach Facility. System Action: Processing for the current profile stops. User Response: Refer to accompanying message STR9511E for additional information. Notify the Strobe system programmer of the problem. STR9515E LOAD OF MODULE modname FAILED Explanation: An attempt to load module modname from either a link list dataset or the library specified by STEPLIB failed. System Action: Processing for the current profile stops. User Response: Notify the Strobe system programmer of the problem. STR9516E CREATION OF TEMPORARY FILE FAILED Explanation: Strobe SQL analysis cannot allocate a temporary file. System Action: Processing for the current Profile stops. User Response: Notify the Strobe system programmer of the problem. STR9517E ALLOCATION OF TABLE INDEX FAILED Explanation: Strobe SQL analysis cannot allocate an internal table. System Action: Processing for the current Profile stops. User Response: Notify the Strobe system programmer of the problem. STR9518E ALLOCATION OF PLAN BUFFER FAILED Explanation: Strobe SQL analysis cannot allocate an internal table. System Action: Processing for the current Profile stops. User Response: Notify the Strobe system programmer of the problem. STR9519E DEFINITION FOR PLAN planname NOT FOUND Explanation: Strobe SQL analysis cannot retrieve the application qualifier for plan planname. The sample dataset for which a Profile request was submitted contains the qualifier. System Action: Processing for all SQL statements associated with planname stops. User Response: Ensure that planname identifies a valid plan in the DB2 catalog. STR9521E EXPLAIN FAILED, SEE PRECEDING MESSAGE(S) Explanation: System Action: An attempt to issue an SQL EXPLAIN failed. Processing for the current SQL statement stops. User Response: If you receive the DB2 error message SQL=-104, a possible cause may be that Strobe SQL analysis is attempting to process truncated static SQL statements. Your application may contain statements greater than 4,096 bytes in length, but a DB2 limitation prevents Strobe from reporting on statements of that length. Refer to messages following STR9531I for additional information. STR9522E DELETE FAILED, SEE PRECEDING MESSAGE(S) Explanation: An attempt to issue an SQL DELETE failed. This occurs at the end of processing for a DB2 subsystem only. System Action: Processing for the current SQL statement stops. User Response: Refer to messages following STR9531I for additional information. STR9523E ATTEMPT TO GET OR SET AUTHORIZATION ID FAILED, SEE PRECEDING MESSAGE(S) Explanation: An attempt to either retrieve the primary authorization ID or set a secondary authorization ID failed. 3-256 Strobe Messages Guide System Action: Processing for the current Profile stops. User Response: Refer to preceding messages for additional information. STR9524E SET FAILED Explanation: An attempt to issue an SQL SET failed. System Action: Processing for the current Profile stops. User Response: Refer to messages following STR9531I for additional information. STR9525E PREPARE FAILED sqlstmttext... Explanation: An attempt to issue an SQL PREPARE for the SQL statement identified by sqlstmttext failed. System Action: Processing for the current SQL statement stops. User Response: Refer to messages following STR9531I for additional information. STR9526E OPEN CURSOR FAILED Explanation: An attempt to issue an SQL OPEN CURSOR failed. System Action: Processing for the current SQL statement stops. User Response: Refer to messages following STR9531I for additional information. STR9527E FETCH FAILED Explanation: An attempt to issue an SQL FETCH failed. System Action: Processing for the current SQL statement stops. User Response: Refer to messages following STR9531I for additional information. STR9528E CLOSE CURSOR FAILED Explanation: An attempt to issue an SQL CLOSE CURSOR failed. System Action: Processing continues. User Response: Refer to messages following STR9531I for additional information. STR9529E CREATE TABLE FAILED Explanation: An attempt to issue an SQL CREATE TABLE failed. System Action: Processing for the current Profile stops. User Response: Refer to messages following STR9531I for additional information. STR9530E EXEC IMMEDIATE FAILED sqlstmttext... Explanation: An attempt to issue an SQL EXEC IMMEDIATE for the SQL statement identified by sqlstmttext failed. System Action: Processing for the current SQL statement stops. User Response: Refer to messages following STR9531I for additional information. STR9531I DB2 MESSAGES BEGIN: Explanation: error begins. The SQL Communication Area (SQLCA) and message text produced for a DB2 If you receive the DB2 error message SQL=-104, a possible cause may be that Strobe SQL analysis is attempting to process truncated static SQL statements. Your application may contain statements greater than 4,096 bytes in length, but a DB2 limitation prevents Strobe from reporting on statements of that length. System Action: Processing continues reporting the DB2 error. User Response: apparent. Notify Compuware Customer Support if the cause of the problem is not Messages Produced by Strobe STR9532I 3-257 DB2 MESSAGES END Explanation: error end. The SQL Communication Area (SQLCA) and message text produced for a DB2 System Action: Processing of the DB2 request terminates. User Response: None required. STR9533E GENERATION OF STATISTICS FOR CURRENT SUBSYSTEM FAILED, SEE PRECEDING MESSAGE(S) Explanation: An error occurred while generating the Catalog Statistics report. System Action: continues. Strobe SQL Analysis processing terminates. Performance Profile creation User Response: Refer to preceding messages for additional information. STR9534E INVALID SQL STATEMENT sqlstmttext Explanation: An error was found in the text of SQL statement sqlstmttext. System Action: Processing for the current SQL statement stops. User Response: Notify Compuware Customer Support of the problem. STR9535E GENERATION OF stattype STATISTICS FAILED, SEE PRECEDING MESSAGE(S) Explanation: An error occurred during generation of the stattype statistics, where stattype is one of the following: • • • • • • • Table Column Index Index partition Non-uniform column Tablespace Tablespace partition System Action: Processing for the current profile stops. User Response: Refer to preceding messages for additional information. STR9536E DATABASE RESOURCE UNAVAILABLE, SEE FOLLOWING MESSAGE(S) Explanation: A DB2 Call Attach Facility error occurred processing an open service request because a required resource is not available. System Action: Processing for the current profile stops. User Response: Ensure that the Strobe SQL analysis plan STRANANA exists in the DB2 subsystem identified in message STR9513I. Refer to the message block beginning with STR9531I that follows STR9536E to identify the unavailable resource. STR9537E TABLE DEFINITION FOR tablename NOT FOUND Explanation: Strobe SQL analysis encountered an internal error attempting to retrieve a control block for table tablename. System Action: Processing for the current SQL statement stops. User Response: Notify Compuware Customer Support of the problem. STR9538E INVALID EXECUTION TYPE: exectype Explanation: The statement execution type exectype passed to Strobe SQL analysis is invalid. System Action: Processing for the current SQL statement stops. User Response: Notify Compuware Customer Support of the problem. STR9540E REPORT reportnumber NOT FOUND Explanation: An attempt by Strobe SQL analysis to locate report reportnumber in the sample file when using existing PLAN_TABLE rows failed. 3-258 Strobe Messages Guide Either no DB2 SQL activity was recorded during measurement or an error occurred during measurement, so the DB2 information required to complete the Profile request is incomplete. System Action: Processing for the Profile stops. User Response: apparent. Notify Compuware Customer Support of the problem if the cause is not STR9542E ALLOCATION OF CURSOR INDEX FAILED Explanation: table. Strobe SQL analysis cannot allocate sufficient virtual storage for an internal System Action: Processing for the current Profile stops. User Response: Notify the Strobe system programmer of the problem. STR9543E CURSOR INDEX BUILD FAILED Explanation: System Action: Strobe SQL analysis cannot build an internal table. Processing for the current Profile stops. User Response: Refer to accompanying message STR9504E or messages following STR9531I for additional information. STR9544E NO PLAN_TABLE ROWS FOR STATEMENT mfstmtnumber (srcstmtnumber) IN objecttype objectname OF PLAN planname Explanation: An attempt by Strobe SQL analysis to locate existing PLAN_TABLE rows for statement mfstmtnumber (srcstmtnumber) in objecttype objectname of plan planname failed. • objecttype identifies objectname as either a package or a DBRM. • mfstmtnumber is the SQL statement number assigned by Strobe. • srcstmtnumber is the SQL statement number assigned by the DB2 precompiler that EXPLAIN inserts into the QUERYNO column of table PLAN_TABLE. One of the following has occurred: • EXPLAIN(YES) was not specified when objectname was bound into plan planname. • The resolved authorization ID does not qualify the correct instance of PLAN_TABLE. System Action: Processing for the current SQL statement stops. User Response: Check the AUTHID and USEPTRWS options. Notify Compuware Customer Support of the problem if it cannot be resolved by changing options. STR9545E NO EXISTING PLAN_TABLE FOUND FOR AUTHORIZATION ID authID Explanation: An attempt by Strobe SQL analysis to locate an instance of PLAN_TABLE for authorization ID authID when using existing PLAN_TABLE rows failed. System Action: Processing of SQL statements for the current collection or DBRM stops. User Response: See the following message, STR9562E, to identify the collection/DBRM name. Check the AUTHID and USEPTRWS options. Notify Compuware Customer Support of the problem if the problem cannot be resolved by changing options. STR9546E NO INDEX SLOTS AVAILABLE, CURRENT NUMBER OF SLOTS IS slotcount Explanation: slotcount. Strobe SQL analysis encountered an overflow in an internal table of size System Action: Processing for the current SQL statement stops. User Response: Notify Compuware Customer Support of the problem. STR9547W CURRENT OF CURSOR NOT PROCESSED: sqlstmttext Explanation: Strobe SQL analysis does not process SQL statements containing a “WHERE CURRENT OF” clause. Refer the declaration of the cursor in sqlstmttext for access path information. System Action: Processing for the current SQL statement stops. Messages Produced by Strobe User Response: STR9550E 3-259 None required. CURSOR INDEX ENTRY entry NOT FOUND Explanation: An attempt by Strobe SQL analysis to locate internal index entry entry when using existing PLAN_TABLE rows failed. System Action: Processing for the current SQL statement stops. User Response: If you have the required DB2 privileges, resubmit the Profile creation request without specifying Y in the USE EXISTING PLAN-TABLE ROWS field on the Strobe - SQL Analysis Feature Report Settings panel. Notify Compuware Customer Support of the problem. STR9551E LOAD OF RULE THRESHOLD SET ruleset FAILED Explanation: System Action: An attempt by Strobe SQL analysis to load rule threshold set ruleset failed. Processing for the current Profile stops. User Response: Ensure that the value of ruleset specified in the RULE THRESHOLD SET field of the Strobe - SQL Analysis Feature Report Settings panel identifies a valid, loadable PDS member, and that the member is in a library that is available to SQL Analysis during Profile creation. STR9552E UNDEFINED TOKEN TEXT: tokenid (firsttoken) Explanation: An attempt by Strobe SQL analysis to locate an entry for token tokenid in an internal table failed. System Action: Processing for the current SQL statement continues, but the text “(undefined)” will appear in the Translation report. User Response: STR9553E Notify Compuware Customer Support of the problem. I/O ERROR ON FILE ID fileid: text Explanation: Strobe SQL analysis encountered an I/O error while processing the file identified by fileid. text describes the reason for the error. Note: A fileid of //tmp:## is the equivalent of DDNAME SYSTMP##. System Action: Processing for the current Profile stops. User Response: apparent. Notify Compuware Customer Support if the cause of the problem is not STR9554E INVALID EXECUTION TYPE FOR EXISTING PLAN_TABLE ROWS: exectype Explanation: The statement execution type exectype passed to Strobe SQL analysis is not a valid type when using existing PLAN_TABLE rows; existing PLAN_TABLE rows can be used for embedded, static SQL statements associated with DBRMs for which Strobe recorded measurement activity. System Action: Processing for the current SQL statement stops. User Response: Enter N in the USE EXISTING PLAN-TABLE ROWS field in the Strobe - SQL Analysis Feature Report Settings panel and recreate the Profile. STR9555E EXPECTED TOKEN NOT FOUND IN STATEMENT: mfstmtnumbertext:sqlstmttext Explanation: An internal error occurred in Strobe SQL analysis while parsing SQL statement sqlstmttext, where mfstmtnumber is the SQL statement number assigned by Strobe. System Action: Processing for the current SQL statement stops. User Response: Notify Compuware Customer Support of the problem. STR9556E ALLOCATION OF DATABASE OBJECT BUFFER FAILED Explanation: Strobe SQL analysis cannot allocate an internal table. System Action: Processing for the current SQL statement stops. User Response: Notify the Strobe system programmer of the problem. 3-260 Strobe Messages Guide STR9557E RETRIEVAL OF DATABASE OBJECT object FAILED Explanation: System Action: Strobe SQL analysis cannot resolve the definition for database object object. Processing for the current SQL statement stops. User Response: Ensure that object identifies an existing database object in the catalog of the DB2 subsystem against which Strobe SQL analysis connected. To determine to which subsystem Strobe SQL analysis connected, first review the PF Parameters line in the Report Parameters section of the Measurement Session Data report. If you requested that Strobe SQL analysis connect to a specific DB2 subsystem, the report displays that subsystem ID following PF parameter SSID. Otherwise, Strobe SQL analysis connected to the subsystem identified in the Subsystems line of the Measurement Parameters section in the Measurement Session Data report. If object does identify a valid object in the DB2 subsystem, refer to the messages that precede STR9557E for additional information. STR9558E DEFINITION FOR objecttype objectname NOT FOUND Explanation: Strobe SQL analysis cannot retrieve objectname that exists in the sample dataset for which a Profile request was submitted. objecttype identifies a package or DBRM. System Action: Processing for all SQL statements associated with objectname stops. User Response: Ensure that objectname identifies a valid object of type objecttype in the DB2 catalog of the DB2 subsystem to which Strobe SQL analysis connected. STR9559W OPEN FOR TRACE OUTPUT FILE FAILED, TRACE OPTION DISABLED Explanation: System Action: Strobe SQL analysis cannot open the file into which it writes trace output. Strobe SQL analysis disables generation of trace output for the Profile. For batch jobs, Strobe SQL analysis writes trace output to the file defined for ddname SYSTERM. User Response: the job. Insert a data definition statement for SYSTERM into your JCL and resubmit STR9560E INCOMPLETE PLAN_TABLE DEFINED FOR AUTHORIZATION ID authID OR SQL STATEMENT CONTAINS CORRELATED REFERENCE THAT IS NOT DEFINED IN THE SQL STATEMENT BEING EXPLAINED Explanation: The instance of PLAN_TABLE defined for authorization ID authID does not contain all the columns required by Strobe SQL analysis. System Action: Processing for the current Profile stops. User Response: See the Response for each Scenario below. Scenario 1: User has selected USE SELECTED PLAN_TABLE ROWS =Y and CREATOR ID=XXX where XXX is the prefix of the existing plan table. For example, if DB2P.PLAN_TABLE is what the customer uses, they should specify DB2P as the CREATOR ID. Problem: If the STR9560E error occurs, this indicates the customer is using a PLAN_TABLE that is back-leveled in DB2 support. For example, the Strobe measurement could have been for DB2 Version 7.1. so SQLAF expects a 7.1-formatted PLAN_TABLE. However, the existing PLAN_TABLE does not have the additional columns that have added for DB2 V7.1 Instead, the PLAN_TABLE may still be in DB2 V6.1 or V5.1 format. SQLAF will fail when it does the SELECT for that statement because the columns may be missing from that PLAN_TABLE. Response: Either DROP the instance of PLAN_TABLE defined for authID and let Strobe SQL analysis create a new instance during a subsequent Profile request, or ALTER the PLAN_TABLE so that it includes the complete set of columns that you can define for PLAN_TABLE. Messages Produced by Strobe 3-261 Scenario 2: User has selected DYNAMIC EXPLAIN WHERE USE EXISTING PLAN_TABLE ROWS=N, CREATOR ID should be blank and AUTH ID may be specified but isn’t required. Problem: If the STR9560E error occurs, this indicates the customer is using a PLAN_TABLE that is back-leveled in DB2 support. Even for DYNAMIC EXPLAIN, If a user is dynamically generating EXPLAIN for a SQL statement into a PLAN_TABLE that already exists, SQLAF will process cleanly on the EXPLAIN, but will fail when it attempts to select that row, just as in Scenario 1. Refer to the IBM manuals IBM DATABASE 2 SQL Reference and IBM DATABASE 2 Administration Guide, Volume III for additional information regarding the definition of PLAN_TABLE. Response: Either DROP the instance of PLAN_TABLE defined for authID and let Strobe SQL analysis create a new instance during a subsequent Profile request, or ALTER the PLAN_TABLE so that it includes the complete set of columns that you can define for PLAN_TABLE. Scenario 3: The STR9560E message is preceded by an STR9531I DB2 MESSAGES BEGIN: SQLCODE= -206 correlation-name.column IS NOT A COLUMN OF AN INSERTED TABLE, UPDATED TABLE, OR ANY TABLE IDENTIFIED IN A FROM CLAUSE, OR IS NOT THE COLUMN OF THE TRIGGERING TABLE OF A TRIGGER and STR9530E EXEC IMMEDIATE FAILED error message for an EXPLAIN SQL statement. The SQL statement being explained by SQLAF was captured from a Trigger that was executed during a Strobe DB2 measurement session. The correlation-name can be either a DB2 correlated reference or table identifier found in a REFERENCING clause for a CREATE TRIGGER. Refer to the DB2 SQL Reference manual for the complete CREATE TRIGGER syntax. Problem: The SQL in the EXPLAIN statement contains a reference to a column name using a correlation name or table identifier that is defined in the REFERENCING clause of a CREATE TRIGGER. Because the reference is defined outside the actual SQL statement being explained, DB2 is not able to determine what object the correlation name or table identifier refers to. Response: There is no workaround that allows the EXPLAIN statement to be successfully processed. The SQLAF processing will continue, but no information (EXPLAIN information, Statistics, Observations, etc.) will be generated for this SQL statement. STR9561E STR9561E DB2 VERSION version NOT SUPPORTED Explanation: The version of Strobe SQL analysis that you invoked while creating a Profile does not support the version of DB2 identified in version. System Action: Processing for the current Profile stops. User Response: Notify the Strobe system programmer. STR9562E ATTEMPT TO SET COLLECTION ID collid FAILED, SEE PRECEDING MESSAGE(S) Explanation: An attempt by Strobe SQL analysis to use the package set identified by collection collid failed. System Action: Processing for the current Profile stops. User Response: To determine for which collection ID, Strobe SQL analysis generated this message, refer to the value following CATCRID in the PF Parameters line of the Report Parameters section in the Measurement Session Data report. Also, refer to the messages that precede STR9562E for additional information. STR9563E ALLOCATION OF TOKEN STACK FAILED Explanation: Strobe SQL analysis cannot build an internal table. System Action: Processing for the current SQL statement stops. User Response: Refer to accompanying message STR9504E for additional information. 3-262 Strobe Messages Guide STR9564E UNDEFINED TOKEN FOUND: tokentext Explanation: Strobe SQL analysis encountered an undefined token tokentext while parsing the current SQL statement. System Action: Processing for the current SQL statement stops. User Response: Refer to accompanying message STR9555E for additional information. Notify Compuware Customer Support of the problem. STR9565W PROCESSING FOR STATEMENT mfstmtnumber IN objecttype objectname OF PLAN planname WAS UNSUCCESSFUL Explanation: Strobe SQL analysis did not successfully process SQL statement mfstmtnumber in DBRM objectname bound to plan planname: • mfstmtnumber is the SQL statement number assigned by Strobe for DB2. • objecttype identifies objectname as either a package or a DBRM. • planname identifies the plan into which the user bound objectname. System Action: Processing for the current SQL statement stops. User Response: Refer to the messages that precede STR9565W for additional information. STR9566I FUNCTION_TABLE CREATED FOR AUTHORIZATION ID authID User Response: Strobe SQL analysis created an instance of FUNCTION_TABLE for authorization ID authID during Profile creation. System Action: Strobe continues processing. User Response: None required. STR9567W MESSAGES ERROR OCCURRED DURING ACCESS OF FUNCTION_TABLE, SEE PRECEDING Explanation: An attempt by Strobe SQL analysis during Profile creation either to create an instance of FUNCTION_TABLE for the resolved authorization ID or to locate an instance of FUNCTION_TABLE when using existing PLAN_TABLE rows failed. System Action: The user-defined function section of the Translation report will not appear. User Response: If the Profile request specified use of existing PLAN_TABLE rows, ensure that an instance of FUNCTION_TABLE exists for the specified authorization ID. Otherwise, refer to preceding messages for additional information. STR9568W ALLOCATION OF FUNCTION TABLE BUFFER FAILED Explanation: Strobe SQL analysis cannot allocate an internal table. System Action: Processing continues. User Response: Notify the Strobe system programmer of the problem. STR9569W INCOMPLETE FUNCTION_TABLE DEFINED FOR AUTHORIZATION ID authID Explanation: The instance of FUNCTION_TABLE defined for authorization ID authID does not contain all the columns required by Strobe SQL analysis. System Action: The user-defined function section of the Translation report will not appear. User Response: Either DROP the instance of FUNCTION_TABLE defined for authID and let Strobe SQL analysis create a new instance during a subsequent Profile request, or ALTER the FUNCTION_TABLE so that it includes the complete set of columns that you can define for FUNCTION_TABLE. Refer to the IBM manuals IBM DATABASE 2 SQL Reference and IBM DATABASE 2 Administration Guide, Volume III for additional information regarding the definition of FUNCTION_TABLE. STR9570W NO FUNCTION_TABLE ROWS FOR STATEMENT mfstmtnumber (srcstmtnumber) IN objecttype objectname OF PLAN planname Explanation: An attempt by Strobe SQL analysis to locate existing FUNCTION_TABLE rows for statement mfstmtnumber (srcstmtnumber) in objecttype objectname of plan planname failed. • objecttype identifies objectname as either a package or a DBRM. Messages Produced by Strobe 3-263 • mfstmtnumber is the SQL statement number assigned by Strobe. • srcstmtnumber is the SQL statement number assigned by the DB2 precompiler that EXPLAIN inserts into the QUERYNO column of table PLAN_TABLE. EXPLAIN(YES) was not specified when objectname was bound into plan planname. The resolved authorization ID does not qualify the correct instance of FUNCTION_TABLE. System Action: The user-defined function section of the Translation report will not appear. User Response: Rebind the plan with the correct authorization ID and EXPLAIN(YES) if the user_defined function section of the Translation report is desired. STR9571I NO EXISTING FUNCTION_TABLE FOUND FOR AUTHORIZATION ID authID Explanation: An attempt by Strobe SQL Analysis to locate an instance of FUNCTION_TABLE for authorization ID authID when using existing PLAN_TABLE rows failed. System Action: The user-defined function section of the Translation report will not appear. User Response: Verify the value of the AUTHORIZATION ID on the Strobe - SQL Analysis Feature Report Settings panel. Notify Compuware Customer Support if you are unable to resolve the problem. STR9572W FAILED ALLOCATION OF QUERYINFO BUFFER FAILED or ALLOCATION OF PREDICATE BUFFER Explanation: Strobe SQL Analysis cannot allocate an internal table. System Action: Processing continues. User Response: Notify the Strobe system programmer of the problem. STR9577I REASON - msg_Text Explanation: An IO Error occurred in SQLAF during its processing. The msg_Text indicates the cause and reason code for the failure. System Action: Processing for the current SQL statement stops. A valid profile for the current SQL statement may or may not be produced. User Response: Consult the z/OS Language Environment Run Time Messages documentation for the errno2 and message text produced. Take the appropriate action. If the cause of the problem cannot be determined, then notify Compuware Customer Support. STR9580E BUFFER OVERFLOW OCCURRED WHILE FORMATTING SQL STATEMENT Explanation: Strobe SQL analysis encountered an internal error when attempting to prepare an SQL statement for processing. System Action: Processing for the current profile/statement stops. User Response: Notify Compuware Customer Support of the problem. STR9581E qqqqqqqq. Object xxxxxxxx was not found in the DB2 catalog with a USER specified qualifier of Explanation: The user specified a default qualifier of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq in the DB2 subsystem. System Action: The SQL Analysis program will produce no reports for this SQL statement but will continue to process any other SQL statements passed to it. User Response: The user may research the correct object qualifier and resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9582E Object xxxxxxxx was not found in the DB2 catalog with a Measurement obtained qualifier of qqqqqqqq. Explanation: Measurement obtained a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq or any other qualifier in the DB2 subsystem. 3-264 Strobe Messages Guide System Action: The SQL Analysis program will produce no reports for this SQL statement but will continue to process any other SQL statements passed to it. User Response: The user may research the correct object qualifier and resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9583E Object xxxxxxxx was not found in the DB2 catalog with an SQL Analysis determined qualifier of qqqqqqqq. Explanation: SQL Analysis determined a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq or any other qualifier in the DB2 subsystem. System Action: The SQL Analysis program will produce no reports for this SQL statement but will continue to process any other SQL statements passed to it. User Response: The user may research the correct object qualifier and resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9584W Object xxxxxxxx was not found in the DB2 catalog with a Measurement obtained qualifier of qqqqqqqq. One of the many qualifiers found uuuuuuuu was used to process this SQL statement. Explanation: Measurement obtained a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq. SQL Analysis found many qualifiers for object xxxxxxxx in the DB2 subsystem and used qualifier uuuuuuuu to process this SQL statement. System Action: statement. Processing continues and there will be reports produced for this SQL User Response: If the qualifier selected was incorrect, the user may resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9585W Object xxxxxxxx was not found in the DB2 catalog with a SQL Analysis determined qualifier of DQ. One of the many qualifiers found, QU was used to process this SQL statement. Explanation: SQL Analysis determined a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq. SQL Analysis found many qualifiers for object xxxxxxxx in the DB2 subsystem and used qualifier uuuuuuuu to process this SQL statement. System Action: statement. Processing continues and there will be reports produced for this SQL User Response: If the qualifier selected was incorrect, the user may resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9586W Object xxxxxxxx was not found in the DB2 catalog with a Measurement-obtained qualifier of qqqqqqqq. One qualifier uuuuuuuu was found and used to process this SQL statement. Explanation: Measurement obtained a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq. SQL Analysis found one qualifier uuuuuuuu for object xxxxxxxx in the DB2 subsystem and used qualifier it to process this SQL statement. System Action: statement. Processing continues and there will be reports produced for this SQL User Response: If the qualifier selected was incorrect, the user may resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9587W Object xxxxxxxx was not found in the DB2 catalog with an SQL Analysis-determined qualifier of qqqqqqqq. One qualifier uuuuuuuu was found and used to process this SQL statement. Explanation: SQL Analysis determined a default qualifier for this object of qqqqqqqq. The SQL Analysis program found no object xxxxxxxx with a qualifier of qqqqqqqq. SQL Analysis found Messages Produced by Strobe 3-265 many qualifiers for object xxxxxxxx in the DB2 subsystem and used qualifier uuuuuuuu to process this SQL statement. System Action: statement. Processing continues and there will be reports produced for this SQL User Response: If the qualifier selected was incorrect, the user may resubmit the SQL Analysis for this SQL statement using iStrobe SQLAF on Demand or execute the reporter/SQLAF run again with the correct default qualifier. STR9599I release_number Explanation: Strobe SQL analysis version release_number has been validated by Strobe. System Action: Processing continues. User Response: None required. Messages Returned by Strobe for DB2 Installation Verification Routine STR9600E UNABLE TO FIND ABOVE LOAD MODULES IN //STRLIB Explanation: The verification program could not find the Strobe Load modules, shown in the Load Module Information section, in the //STRLIB DD library. System Action: The verification program continues and will end with a return code of 8. User Response: Ensure that the STRBLIB dataset is correct and contains the load modules that were listed as missing in the Load Module Information section of the verification report and resubmit the job. STR9601E STROBE LOAD MODULES MARKED WITH * ABOVE DO NOT BELONG TO THIS RELEASE OF Explanation: The verification program found the Strobe Load modules, marked with an * in the Load Module Information section, in the //STRLIB DD library, but the version of the module found does not belong to this release of Strobe. System Action: The verification program continues and will end with a return code of 8. User Response: Ensure that the STRBLIB dataset is correct and contains the correct versions of the load modules that were listed marked with an * in the Load Module Information section of the verification report and resubmit the job. STR9602E UNABLE TO FIND DBRM dbrmname IN //DBRMLIB Explanation: The verification program could not find the Strobe DBRM module, dbrmname, in the //DBRMLIB DD library. System Action: The verification program continues and will end with a return code of 8. User Response: Ensure that the CNTL dataset is correct and contains the dbrm module that was listed as missing in the DBRM Information section of the verification report and resubmit the job. STR9603E THE DBRM VERSION OF dbrmname IN THE //DBRMLIB LIBRARY DOES NOT MATCH THE LOAD MODULE VERSION OF modulename IN //STRLIB Explanation: The verification program detected that the load module modulename does not match the corresponding DBRM dbrmname. The versions of these modules must match. System Action: The verification program continues and will end with a return code of 8. User Response: Please ensure that the versions match and resubmit the job. STR9604E THERE ARE NO rrvvmm VERSIONS OF DBRM dbrmname FOUND IN SYSIBM.SYSPACKAGE Explanation: The verification program detected that no versions for the release of Strobe, indicated by rrvvmm and DBRM name dbrmname, exist in the DB2 Catalog Table SYSIBM.SYSPACKAGE. 3-266 Strobe Messages Guide System Action: The verification program continues and will end with a return code of 8. User Response: • dbrmname STRDFIFM is required by Strobe's DB2/DDF processing. Please refer to installation job STRBPBND. • dbrmname STRDNMOD and STRDNSVC are required by Strobe's SQL Analysis and DB2 users of iStrobe. If this applies, please refer to installation job STANPBND. STR9605E NO rrvvmm VERSIONS OF DBRM dbrmname FOUND IN SYSIBM.SYSPACKAGE THAT MATCH THE VERSION IN THE //DBRMLIB LIBRARY Explanation: The verification program detected that versions for the release of Strobe, indicated by rrvvmm and DBRM name dbrmname, exist in the DB2 Catalog Table SYSIBM.SYSPACKAGE, but none that match the version that was found in the //DBRMLIB Library. System Action: The verification program continues and will end with a return code of 8. User Response: • dbrmname STRDFIFM is required by Strobe's DB2/DDF processing. Please refer to installation job STRBPBND. • dbrmname STRDNMOD and STRDNSVC are required by Strobe's SQL Analysis and DB2 users of iStrobe. If this applies, please refer to installation job STANPBND. STR9606E THERE ARE NO DB2 COLLECTIONS FOUND THAT ARE BOUND INTO STROBE'S PLAN STRANANA Explanation: The verification program detected that no DB2 collections have been bound into Strobe’s DB2 plan STRANANA. System Action: The verification program continues and will end with a return code of 8. User Response: Please refer to installation job STRPLBND. STR9607E EXECUTE AUTHORITY HAS NOT BEEN GRANTED TO STROBE'S PLAN STRANANA Explanation: The verification program detected that no grant request for EXECUTE authority has taken place Strobe’s DB2 plan STRANANA. System Action: The verification program continues and will end with a return code of 8. User Response: Please refer to installation job STRANGNT. STR9608E TRACE/MONITOR2 AUTHORIZATION HAS NOT BEEN GRANTED TO STROBE'S SSA Explanation: The verification program detected that no grant request for TRACE/MONITOR2 authorization has taken place for Strobe's SSA. System Action: The verification program continues and will end with a return code of 8. User Response: Please refer to installation job STRBGRNT. STR9609E DB2 returned a non-zero return code Explanation: An unexpected SQLCODE was returned to the verification program by DB2. This message will be followed by the DB2 message DSNT408I detailing the SQLCODE returned. System Action: The verification program terminates with a return code of 12. User Response: Typically this is caused by a problem with the bind for the verification program STRANVER and its DBRM STRDNVER. Please refer to installation job STRBPBND. STR9610E UNABLE TO ACCESS MODULE INFORMATION IN //STRLIB Explanation: An unexpected situation occurred when the verification program attempted to access the libraries in the //STRLIB library concatenation. System Action: The verification program terminates with a return code of 12. User Response: Please contact Compuware Customer Support. STR9611E UNABLE TO ACCESS MODULE INFORMATION IN //DBRMLIB Explanation: An unexpected situation occurred when the verification program attempted to access the libraries in the //DBRMLIB library concatenation. Messages Produced by Strobe System Action: The verification program terminates with a return code of 12. User Response: Please contact Compuware Customer Support. 3-267 STR9612E STROBE'S DB2 INSTALLATION VERIFICATION WAS UNSUCCESSFUL. PLEASE REFER TO THE STROBE MESSAGES GUIDE FOR MORE INFORMATION Explanation: An unexpected situation occurred when the verification job ran. Additional information is available in the Strobe Messages Guide. System Action: The verification program continues. User Response: Please refer to the Strobe Messages Guide regarding any other messages provided by the verification program. 3-268 Strobe Messages Guide 4-1 Chapter 4. Messages Returned by Global Monitoring Chap 4 STRGB0001I Strobe Monitoring for batch initialization in progress Severity: Informational Explanation: The Strobe Monitoring task for batch jobs is initializing. System Action: Processing continues. User Response: None. STRGB0002I Strobe Monitoring for batch initialization complete Severity: Informational Explanation: The Strobe Monitoring task for batch jobs has completed initialization. System Action: Processing continues. User Response: None. STRGB0003I Strobe Monitoring for batch termination in progress Severity: Informational Explanation: The Strobe Monitoring task for batch jobs is terminating. System Action: Processing continues. User Response: None. STRGB0004I Strobe Monitoring for batch termination complete return code @@ Severity: Informational Explanation: The Strobe Monitoring task for batch jobs has terminated. The return code is shown in the message System Action: Processing continues. User Response: None. STRGB0031S Unable to obtain storage for @@ data area. Return code=@@. Severity: Severe Explanation: The Strobe Monitoring for batch task attempted to obtain storage for a data area. The storage request failed. The name of the data area and the return code from the STORAGE OBTAIN macro instruction are shown in the message. System Action: Processing continues. User Response: Be certain that sufficient storage is available the MNAS. STRGB0900I @@ Processing work queue. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGC0001S Unable to load module @@. CICS monitoring shutting down. Severity: Severe Explanation: The Strobe Monitoring task for CICS was unable to load a required module. The module name is shown in the message. 4-2 Strobe Messages Guide System Action: Strobe monitoring for CICS terminates. User Response: Address Space. Ensure the module named in the message is available to the Monitoring STRGC0101I Strobe Monitoring for CICS initialization in progress Severity: Informational Explanation: The Strobe Monitoring task for CICS is initializing. System Action: Processing continues. User Response: None. STRGC0102I Strobe Monitoring for CICS initialization complete Severity: Informational Explanation: The Strobe Monitoring task for CICS has completed initialization. System Action: Processing continues. User Response: None. STRGC0103I Strobe Monitoring for CICS termination in progress Severity: Informational Explanation: The Strobe Monitoring task for CICS is terminating. System Action: Processing continues. User Response: None. STRGC0104I Strobe Monitoring for CICS termination complete return code @@ Severity: Informational Explanation: The Strobe Monitoring task for CICS has terminated. The return code is shown in the message System Action: Processing continues. User Response: None. STRGC0105I Request @@ @@ for JOB @@ JOBID @@ @@ @@ PSTEP @@ received. Severity: Informational Explanation: The Strobe Monitoring task for CICS has been posted to process a request for the JOB, JOBID, and STEP or transaction shown. System Action: Processing for the request begins. User Response: None. STRGC0106E Unable to @@ ALET for JOB @@, ALESERV return code @@ Severity: Error Explanation: The Strobe Monitoring task for CICS was unable to add or delete an ALET used to access CICS storage. The ALESERV return code is shown. System Action: requests. Request processing terminates for ADD requests and continues for DELETE User Response: Repeat the attempt to monitor the CICS region shown in the message. If problem persists contact Compuware Technical Support. STRGC0107I REGISTER in progress for JOB @@ JOBID @@ STEP @@ PSTEP @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is attempting to IDENTIFY the CICS release of the JOB, STEP, and PSTEP shown in the message. System Action: Identification of CICS and its release begins. User Response: None. Messages Returned by Global Monitoring 4-3 STRGC0108I JOB TERM in progress for JOB @@ JOBID @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is attempting to disconnect CICS JOB shown in the message from being monitored. System Action: The JOB will no longer be known to the Strobe Monitoring task. User Response: None. STRGC0109I STEP TERM initiated for JOB @@ JOBID @@ STEP @@ PSTEP @@ FLAGS @@ Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing STEP termination for the STEP and PSTEP in the JOB shown in the message. System Action: The STEP will no longer be known to the Strobe Monitoring task. User Response: None. STRGC0110I @@ found zero (or matching) CICS JOB entries in the system. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing a CICS modify command and either found no JOB entries or none for a specific JOB. System Action: Processing of the command terminates. User Response: Use the CICSDISPLAY command to verify finding no CICS JOB entries or none that match the entered JOB name. STRGC0111I Processing MODIFY command @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS has received a MODIFY command shown in the message. System Action: Process the command. User Response: None. STRGC0112E Invalid MODIFY command received: @@. Severity: Error Explanation: The Strobe Monitoring task for CICS has received an invalid MODIFY command shown in the message. System Action: Command processing terminates. User Response: Review Strobe Global Monitoring MODIFY commands and correct. STRGC0113E CICSSTART found GMMJ for JOB @@ JOBID @@ STEP @@ PSTEP @@ flag @@ Severity: Error Explanation: The Strobe Monitoring task for CICS is processing a CICSSTART command and found an existing entry for the JOB, JOBID, STEP, PSTEP, and flags shown in the message. System Action: Processing of the CICSSTART command terminates. User Response: Review log messages to verify that issuing a CICSSTART command for the JOB is appropriate. Contact Compuware Technical Support if a CICSSTOP for the JOB completed successfully. STRGC0114E CICSSTART could not locate necessary information for JOB @@. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing a CICSSTART command but could not find the necessary information from the ASCB for JOB @@. System Action: Processing of the CICSSTART command terminates. 4-4 Strobe Messages Guide User Response: JOB. Ensure that the JOB is fully initialized before issuing a CICSSTART for the STRGC0115I @@ found entry for JOB @@ JOBID @@ STEP @@ PSTEP @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing a CICSSTOP or CICSPURGE command and found an entry for the JOB, JOBID, STEP, and PSTEP shown the message. System Action: Processing of the CICSSTOP or CICSPURGE command continues. User Response: None. STRGC0116E @@ could not find a tracking entry for JOB @@. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing a CICSDISABLE or CICSENABLE command and could not find an entry for the JOB shown the message. System Action: Processing of the CICSDISABLE or CICSENABLE command terminates. User Response: Check the logs for messages indicating the target JOB had been previously enabled or disabled. STRGC0117E @@ could not find CICS information for JOB @@. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing a CICSDISABLE or CICSENABLE command and could not find associated CICS information for the JOB shown in the message. System Action: Processing of the CICSDISABLE or CICSENABLE command terminates. User Response: Check the logs for messages indicating the target JOB had been previously enabled or disabled. STRGC0118E Identify request for JOB @@ JOB ID @@ reached maximum attempts. Severity: Error Explanation: The Strobe Monitoring task for CICS was attempting to identify the CICS release of the JOB shown but reached the maximum attempts. System Action: Identify processing terminates. User Response: Use the CICSSTOP and CICSSTART commands to re-initialize the identify and implant process, if the JOB is CICS. STRGC0119W @@ JOB name operand @@ exceeds 8 characters. Severity: Warning Explanation: A CICSDISPLAY command was received with a JOB name operand that exceeded 8 characters. System Action: JOB name operand is truncated to the first 8 characters which may result in incorrect results. User Response: If necessary reenter the CICSDISPLAY command with the correct JOB name not to exceed 8 characters. STRGC0120I @@ Last Request @@ Intercept Address @@ Work Area @@ Re @@ FG3 @@ Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing a CICSDISPLAY command and found an entry for the JOB, JOBID, and STEP known to be a CICS JOB. System Action: Processing of the CICSDISPLAY command continues. User Response: None. STRGC0121I @@ CICS Release @@ State @@ Intercept State @@ CBs found @@ Severity: Informational Messages Returned by Global Monitoring 4-5 Explanation: The Strobe Monitoring task for CICS is processing a CICSDISPLAY command and found an entry for the JOB, JOBID, and STEP known to be a CICS JOB. System Action: Processing of the CICSDISPLAY command continues. User Response: None. STRGC0122I @@ CICS Prolog @@ Entry @@ Intercept Prolog @@ Entry @@ State @@ Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing a CICSDISPLAY command and found an entry for the JOB, JOBID, and STEP known to be a CICS JOB. System Action: Processing of the CICSDISPLAY command continues. User Response: None. STRGC0123I @@ found @@ CICS JOB STEP entries in the system. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing a CICSDISPLAY command and found the displayed number of CICS JOB(s) in the system. System Action: Processing of the CICSDISPLAY command terminates. User Response: None. STRGC0124E Cannot implant in JOB @@, it does not meet your monitor criteria. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing a CICSSTART command and found the displayed JOB is either excluded or not included in your STRGMCRI data set. System Action: Processing of the CICSSTART command terminates. User Response: Review your INCLUDE and EXCLUDE criteria using the STRBGMCL utility. STRGC0125I Querying criteria specifications for JOB @@ STEP @@ PSTEP @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is querying the criteria loaded from your STRGMCRI data set to determine if it should be monitored. System Action: Processing depends upon the contents of your STRGMCRI, either the JOB will be monitored or not. User Response: Review subsequent messages and your STRGMCRI contents using the STRBGMCL utility if monitoring is not as expected. STRGC0126I ASVT scan complete, @@ total entries queried with @@ identified. Severity: Informational Explanation: The Strobe Monitoring task for CICS scanned the ASVT looking for JOBs to be monitored based upon your criteria loaded from STRGMCRI. The number of JOBs queried and meeting your criteria are shown. System Action: Processing depends upon the contents of your STRGMCRI, either the JOB(s) will be monitored or not. User Response: Review subsequent messages and your STRGMCRI contents using the STRBGMCL utility if monitoring is not as expected. STRGC0127E The @@ command requires @@. Severity: Error Explanation: The Strobe Monitoring task for CICS was attempting to process the listed command but could not complete because of the stated error condition. System Action: Processing terminates. User Response: Review Global Monitor for CICS command documentation and attempt to repeat the command. 4-6 Strobe Messages Guide STRGC0201E Validity check occured on request @@ for JOB @@ JOBID @@. Severity: Error Explanation: The Strobe Monitoring task for CICS was processing the request for the JOB shown in the message but an internal validity check failed. System Action: Processing of the request terminates. User Response: Contact Compuware Technical Support. STRGC0202I @@ request @@ ended with RC=@@ Reas=@@. Severity: Informational Explanation: The Strobe Monitoring task for CICS was processing a request which ended with a return code and reason code, all shown in the message. System Action: Processing of the request completed. User Response: None. STRGC0203E @@ STORAGE OBTAIN request failed, RC=@@. Severity: Error Explanation: The Strobe Monitoring task for CICS failed to obtain storage in CICS, STORAGE OBTAIN failed with the return code shown. System Action: Processing of the request terminates. User Response: Contact Compuware Technical Support. STRGC0204E @@ Intercept remains from a previously failed DISCONNECT. Severity: Error Explanation: The Strobe Monitoring task for CICS was processing an implant request which found a copy of the intercept in the CICS address space. System Action: Implant processing terminates. User Response: Use the Modify CICSPURGE then CICSSTART commands to start monitoring the target CICS JOB. STRGC0205I @@ Disabled intercept has been instructed to reconnect. Severity: Informational Explanation: The Strobe Monitoring task for CICS was processing an implant request which found a copy of the intercept in the CICS address space. System Action: Implant processing completes. User Response: Ensure that monitoring resumes using the MODIFY CICSDISPLAY command for the target CICS JOB. STRGC0206S @@ Implant processing failed on the swap. Severity: Severe Explanation: The Strobe Monitoring task for CICS was processing an implant request which failed to insert the intercept in the CICS MN domain. System Action: Implant processing terminates. User Response: Use the MODIFY CICSDISPLAY command for the target CICS JOB and contact Compuware Technical Support. STRGC0207E @@ STORAGE RELEASE request failed, address=@@ RC=@@. Severity: Error Explanation: The Strobe Monitoring task for CICS failed to release storage in CICS, STORAGE RELEASE failed with the return code shown. System Action: Processing of the request terminates. User Response: Contact Compuware Technical Support. Messages Returned by Global Monitoring 4-7 STRGC0208E @@ request Implant found @@ already implanted in CICS @@. Severity: Error Explanation: The Strobe Monitoring task for CICS failed to implant the intercept because it found that another MNAS had implanted in this CICS. System Action: Processing of the request terminates. User Response: If desired remove the intercept from the MNAS shown in the message using the CICSSTOP or CICSPURGE command on the CICS JOB. If running multiple MNAS decide which one is to monitor this CICS JOB and update the criteria file. STRGC0300I @@ JOB @@ JOBID @@ STEP @@ is CICS at release @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing an Identify request and found that the JOB is CICS at the release shown. System Action: Identify processing is complete. User Response: None. STRGC0301I @@ JOB @@ JOBID @@ STEP @@ is CICS but not release @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing an Identify request and found that the JOB is CICS but not at the release shown. System Action: Identify processing continues. User Response: None. STRGC0302I @@ JOB @@ JOBID @@ STEP @@ is CICS release @@ but PLTPI not done. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing an Identify request and found that the JOB is CICS at the release shown but is not fully initialized. System Action: Identify processing continues. User Response: None. STRGC0303I @@ JOB @@ JOBID @@ STEP @@ could not find all CBs, found @@. Severity: Informational Explanation: The Strobe Monitoring task for CICS is processing an Identify request but could not find all of the necessary control blocks for identification. A hex representation of what was found is given. System Action: Identify processing continues. User Response: None. STRGC0304E @@ JOB @@ JOBID @@ STEP @@ could not identify DFHMNXM. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing an Identify request but could not identify the IBM DFHMNXM module in order to implant Global Monitoring. System Action: Identify processing terminates. User Response: Contact Compuware Technical Support. STRGC0305E @@ JOB @@ JOBID @@ STEP @@ is CICS but unsupported release @@. Severity: Error Explanation: The Strobe Monitoring task for CICS is processing an Identify request and found that the JOB is CICS but is an unsupported (old) release. System Action: Identify processing terminates. User Response: Monitor supported releases of CICS. 4-8 Strobe Messages Guide STRGC0904I Error sending CICS transaction data to data pump r/c=@@ Reason co de=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGC0905I @@ @@ @@. CPU/Elapsed=@@ @@. Entry=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGC0906I Global Monitoring CICS scheduling SRB. Target job name @@ ASID @@ Function @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGC0907I Global Monitoring CICS SRB schedule failed: @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGC0908I Global Monitoring CICS SYSEVENT failed RC=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0016E Unable to find module @@ r/c=@@ reason code=@@. Severity: Error Explanation: The Strobe Monitoring task for IMS attempted to find the module shown in the message. The return and reason code from the BLDL macro are also shown in the message. System Action: The Strobe IMS task terminates. User Response: Be sure the module shown in the message is in a load library available to the MNAS. STRGI0101I Strobe Monitoring for IMS initialization in progress Severity: Informational Explanation: The Strobe Monitoring task for IMS is initializing. System Action: Processing continues. User Response: None. STRGI0102I Strobe Monitoring for IMS initialization complete Severity: Informational Explanation: The Strobe Monitoring task for IMS has completed initialization. System Action: Processing continues. User Response: None. Messages Returned by Global Monitoring 4-9 STRGI0103I Strobe Monitoring for IMS termination in progress Severity: Informational Explanation: The Strobe Monitoring task for IMS is terminating. System Action: Processing continues. User Response: None. STRGI0104I Strobe Monitoring for IMS termination complete return code @@ Severity: Informational Explanation: The Strobe Monitoring task for IMS has terminated. The return code is shown in the message System Action: Processing continues. User Response: None. STRGI0111I Processing MODIFY command @@. Severity: Informational Explanation: The Strobe Monitoring task for IMS has received a MODIFY command shown in the message. System Action: Process the command. User Response: None. STRGI0112E Invalid MODIFY command received: @@. Severity: Error Explanation: The Strobe Monitoring task for IMS has received an invalid MODIFY command shown in the message. System Action: Command processing terminates. User Response: Review Strobe Global Monitoring MODIFY commands and correct. STRGI0113E Global Monitoring for IMS already active for region @@ job ID @@ ASID @@. Severity: Error Explanation: The Strobe Monitoring task for IMS is processing a IMSSTART command and determined that Global Monitoring for IMS is already active for the IMS region. The job name job ID, and address space ID (ASID) are shown in the message. System Action: Processing of the IMSSTART command terminates for the named IMS region. User Response: Review log messages to verify that issuing a IMSSTART command for the region is appropriate. STRGI0114E IMSSTART could not locate necessary information for JOB @@. Severity: Error Explanation: The Strobe Monitoring task for IMS is processing a IMSSTART command but could not find the necessary information from the ASCB for JOB @@. System Action: Processing of the IMSSTART command terminates. User Response: Ensure that the JOB is fully initialized before issuing a IMSSTART for the JOB. STRGI0119W @@ job name operand @@ exceeds 8 characters. Severity: Warning Explanation: A command was received with a JOB name operand that exceeded 8 characters. System Action: JOB name operand is truncated to the first 8 characters which may result in incorrect results. User Response: If necessary reenter the command with the correct JOB name not to exceed 8 characters. 4-10 Strobe Messages Guide STRGI0120I List of monitored IMS MPP regions follows: Severity: Informational Explanation: The IMSDISPLAY command was recieved and is being processed. A list of the currently monitored IMS MPP regions follows this message. System Action: Processing continues User Response: See message STRGI0121 for information about each MPP region actively being monitored. STRGI0121I IMS MPP region job name: @@. ASID: @@. IMS ID: @@ Severity: Informational Explanation: The IMSDISPLAY command was recieved and is being processed. This message displays information about a MPP region that is currently being monitored. System Action: Processing continues User Response: None. STRGI0123I End of List. @@ IMS MPP region(s) currently monitored Severity: Informational Explanation: The IMSDISPLAY command was received and is being processed. This message concludes the list of currently monitored IMS MPP regions and shows the number of regions currently being monitored. System Action: Processing continues User Response: None. STRGI0124E Cannot implant in JOB @@, it does not meet your monitor criteria. Severity: Error Explanation: The Strobe Monitoring task for IMS is processing a IMSSTART command and found the displayed JOB is either excluded or not included in your STRGMCRI data set. System Action: Processing of the IMSSTART command terminates. User Response: Review your INCLUDE and EXCLUDE criteria using the STRBGMCL utility. STRGI0900I @@ Processing work queue. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0901I Calling STRBGIIM for @@. Job name: @@. IMS ID: @@. Function: @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0902I Calling STRBGIIM for @@. Job name: @@. Function: @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0903I Global Monitoring for IMS SRB module address: @@. Severity: Informational Messages Returned by Global Monitoring Explanation: 4-11 This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0904I Error sending IMS transaction data to data pump r/c=@@ Reason cod e=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0905I @@ @@ @@. CPU/Elapsed=@@ @@. Entry=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI0910E An error occurred attempting to @@. IMS Job name: @@. RC=@@. Severity: Error Explanation: An attempt was made to implant or remove the Strobe Global Monitoring IMS intercept. This attempt failed. The request type (Implant/Remove), the IMS job name and the return code from the implant/remove module are shown in the message. System Action: Processing continues. User Response: If the problem occurred during implant attempt to implant the intercept again using the IMSSTART command. If the problem occurred during remove, attempt to remove the intercept again using the IMSSTOP command. If the problem persists, contact Compuware Technical Support. STRGI1016E Unable to find module @@ r/c=@@ reason code=@@. Severity: Error Explanation: The Strobe Monitoring for IMS implant routine attempted to find the module shown in the message. The return and reason code from the BLDL macro are also shown in the message. System Action: The Strobe IMS implant routine terminates. User Response: Be sure the module shown in the message is in a load library available to the Strobe implant routine. STRGI1020I @@ found IMS SVC @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. The program shown in the message found an IMS SVC. The address of the SVC routine is shown in the message. System Action: Processing continues. User Response: None. STRGI1021I Target IMS region found: @@ @@ @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1022I Global Monitoring IMS intercept stub address: @@ Severity: Informational 4-12 Strobe Messages Guide Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1023I IMS Logical Logger (DFSFLLG0) found: @@ @@ @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1024I Global Monitoring IMS intercept address: @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1025I Global Monitoring IMS SRB module address: @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1026I Global Monitoring IMS SRB scheduled. Target job name @@. ASID @@. Function @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1027I Global Monitoring IMS SRB schedule failed: @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1028I Error removing Global Monitoring IMS intercept: @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1309I Name/Token pair @@ not deleted. Name/Token Callable services r/c =@@. Severity: Informational Explanation: The Name/Token pair associated with Global Monitoring for IMS was not deleted. The name portion of the Name/Token pair, and the return code from IBM Name/Token Callable Services are shown in the message. System Action: Processing continues. User Response: None. STRGI1322I Name/Token pair @@ not found. Name/Token Callable Services r/c @ @. Severity: Informational Messages Returned by Global Monitoring 4-13 Explanation: The Name/Token pair associated with Global Monitoring for IMS was not found. This is a normal situation if the MNAS has not been active since the last IPL. The name portion of the Name/Token pair and the return code from IBM Name/Token Callable Services are shown in the message. System Action: Processing continues. User Response: If the return code is 4, none. STRGI1328I Name/Token pair @@ deleted. Severity: Informational Explanation: The Name/Token pair associated with Global Monitoring for IMS was deleted. The name portion of the Name/Token pair is shown in the message. System Action: Processing continues. User Response: None. STRGI1330I GIST address = @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGI1420E Name/Token pair @@ not deleted. MNAS @@ is currently active. Severity: Error Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was not deleted. The MNAS associated with the Name/Token pair is currently active. The name portion of the Name/Token pair and the job name of the MNAS are shown in the message. System Action: Processing continues. User Response: Shut down the MNAS prior to running the Name/Token pair delete utility. STRGI1422I Name/Token pair @@ not found. Name/Token Callable Services r/c @ @. Severity: Informational Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was not found. This is a normal situation if the MNAS has not been active since the last IPL. The name portion of the Name/Token pair and the return code from IBM Name/Token Callable Services are shown in the message. System Action: Processing continues. User Response: If the return code is 4, none. STRGI1500I IMS SVC EPA: @@. SVC number: @@. Severity: Informational Explanation: This message displays the IMS SVC entry point address and the SVC number. System Action: Processing continues. User Response: None. STRGI1501I Dependent region job name: @@. IMS ID: @@. IMS release: @@. Contr ol region: @@. Severity: Informational Explanation: This message displays the job name of an IMS dependent region and the IMS ID with which that region is associated. The IMS release and control region job name are also shown. System Action: Processing continues. User Response: None. 4-14 Strobe Messages Guide STRGM0001I Strobe Monitoring Address Space initialization complete Severity: Informational Explanation: The Monitoring Address Space has successfully initialized. System Action: Processing continues. User Response: None. STRGM0002I Setting address space non-swappable Severity: Informational Explanation: The MNAS is being set non-swappable. System Action: None. User Response: None. STRGM0003I Strobe Monitoring Address Space termination complete Severity: Informational Explanation: The Monitoring Address Space has terminated. System Action: Processing continues. User Response: None. STRGM0006E Unable to load Strobe License Management interface module @@. Severity: Error Explanation: Strobe Monitoring attempted to load the the Strobe License Management interface module. The name of the Strobe License Management interface module is shown in the message. System Action: The Monitoring Address Space terminates. User Response: Contact Compuware Technical Support. STRGM0007E An iStrobe license is required for the @@ component of Strobe Mon itoring. Severity: Error Explanation: The Strobe Monitoring component shown in the message requires an iStrobe license. The verification of licensing for iStrobe indicates that it is not licensed. System Action: The component is not initialized. User Response: To avoid these messages set the component shown in the message to NO in the Strobe parameter data set. To obtain a license for iStrobe contact your Compuware sales representative. STRGM0008E An Autostrobe license is required for Strobe Monitoring. Severity: Error Explanation: Strobe Monitoring requires an Autostrobe license. The verification of licensing for Autostrobe indicates that it is not licensed. System Action: The Monitoring Address Space terminates. User Response: representative. To obtain a license for Autostrobe contact your Compuware sales STRGM0009E Strobe Monitoring license verification failed. R/C @@. Reason @@ . Severity: Error Explanation: The Monitoring Address Space has attempted verify that Strobe is licensed. That attempt has failed. The return code and reason code from License Management name are shown in the message. System Action: The Monitoring Address Space terminates. User Response: Contact Compuware Technical Support. Messages Returned by Global Monitoring 4-15 STRGM0010S Unable to open Strobe Monitoring Address Space log file Severity: Severe Explanation: The Monitoring Address Space has attempted to open the message log file. That attempt has failed. System Action: The Monitoring Address Space terminates. User Response: Space. Correct the reason for the open failure and restart the Monitoring Address STRGM0011I Monitoring repository data set name @@ Severity: Informational Explanation: This message displays the 44 character Monitoring data set name. System Action: Monitoring initialization continues. User Response: None. STRGM0012E Error allocating Monitoring repository data set Severity: Error Explanation: The Monitoring task has attempted to dynamically allocate the repository data set. The attempt was not successful. System Action: Monitoring terminates. User Response: See the subsequent STR0013I message for details about this error. STRGM0013E Dynalloc RC=@@. Error=@@. Reason Code=@@ Severity: Error Explanation: This message displays the dynamic allocation return code, error code and reason code. The previous message indicates the file that was being allocated. System Action: Monitoring processing terminates. User Response: Using the return code, error code and reason code determine the cause of the dynamic allocation failure. STRGM0014E Unable to load monitoring module @@ Severity: Error Explanation: An attempt to load a Strobe monitoring module failed. The name of the module is shown in the message. System Action: The Monitoring Address Space terminates. User Response: Ensure that the module shown in the message is in a library available to the Monitoring Address Space. STRGM0015E Unable to create Default Table (DFT). Return Code=@@ Severity: Error Explanation: An attempt to build the Strobe default table has failed. The return code is shown in the message. System Action: The Monitoring Address Space terminates. User Response: Review the parameter member specified on the PARMLIB DD statement for syntax errors and correct. STRGM0016E Unable to locate monitoring module @@. BLDL r/c=@@ reason code @ @. Severity: Error Explanation: An attempt to locate a Strobe monitoring module failed. The name of the module and the return and reason codes from the BLDL macro instruction are shown in the message. System Action: The Monitoring Address Space terminates. 4-16 Strobe Messages Guide User Response: Ensure that the module shown in the message is in a library available to the Monitoring Address Space. STRGM0017E Error allocating Monitoring criteria data set Severity: Error Explanation: The Monitoring task has attempted to dynamically allocate the criteria. The attempt was not successful. System Action: Monitoring terminates. User Response: See the subsequent STR0013I message for details about this error. STRGM0020I Strobe Monitoring file task initializing Severity: Informational Explanation: The Strobe Monitoring file task is initializing. System Action: Processing continues. User Response: None. STRGM0021I Strobe Monitoring file task initialization complete Severity: Informational Explanation: The Strobe Monitoring file task has completed initialization. System Action: Processing continues. User Response: None. STRGM0022I Strobe Monitoring file task terminating Severity: Informational Explanation: The Strobe Monitoring file task is terminating. System Action: Processing continues. User Response: None. STRGM0024I Strobe Monitoring file task termination complete return code @@ Severity: Informational Explanation: the message The Strobe Monitoring file task has terminated. The return code is shown in System Action: Processing continues. User Response: None. STRGM0030E Attach for subtask @@ failed. Return code=@@ Severity: Error Explanation: An attempt to attach a Strobe monitoring task has failed. The name of the program being attached and the return code from the ATTACH macro instruction are shown in the message. System Action: Processing continues. User Response: error. Using the return code shown in the message, determine the cause of the STRGM0031I Subtask @@ has ended. Completion code @@ Severity: Informational Explanation: A subtask has terminated. The name of the attached program and the completion code are shown in the message. System Action: The subtask is reattached. User Response: If the subtask has abended, save any SVC dumps and the log data set from the MNAS, and contact Compuware Technical Support. Messages Returned by Global Monitoring 4-17 STRGM0032I Subtask @@ is being reattached Severity: Informational Explanation: A subtask has terminated and is being reattached. System Action: Processing continues. User Response: None. STRGM0033S Subtask @@ has failed and will not be reattached Severity: Severe Explanation: A subtask has terminated with a severe error and has indicated that it should not be reattached. The name of the attached program is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. STRGM0034S Subtask @@ has terminated @@ times and will not be reattached Severity: Severe Explanation: A subtask has terminated more frequently than allowed. The name of the attached program is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. STRGM0035E Request to restart @@ processing failed. Subtask entry not found Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed due to an error in an internal control block. The name component is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. STRGM0036E Request to restart @@ processing failed. Subtask is active Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed because the component task is still active. System Action: Processing continues. User Response: Ensure that the task has been terminated before attempting to restart it. STRGM0037I Subtask @@ has terminated Severity: Informational Explanation: A subtask has terminated and has indicated that it may be reattached by the RESTART operator command. The name of the attached program is shown in the message. System Action: Processing continues. User Response: If desired, the task may be restarted using the RESTART operator command. STRGM0038E Request to restart @@ processing failed. Subtask is not eligible for restart Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed because the component task indicated that it cannot be restarted. System Action: Processing continues. User Response: Contact Compuware Technical Support. 4-18 Strobe Messages Guide STRGM0039E Invalid component name specified Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed because the component name specified is invalid. System Action: Processing continues. User Response: Specify a valid component name. Valid component names are BATCH, CICS, and DATAPUMP. STRGM0040E Required SMF record type @@ is not being collected Severity: Error Explanation: The SMF record type shown in the message is required. The SMFRTEST macro indicated that this record is not being collected. System Action: Initialization of the MNAS terminates. User Response: Ensure that the SMF record type shown in the message is being collected at the installation. STRGM0041E Unable to find @@ SMF exit module @@ Severity: Error Explanation: An SMF exit module was not found. The name of the SMF exit and the name of the module are shown in the message. System Action: Initialization of the MNAS terminates. User Response: Ensure that the module shown in the message is in a load library available to the MNAS. STRGM0042E Unable to obtain storage for @@ SMF exit module @@. Return code= @@. Severity: Error Explanation: The Strobe Monitoring main task attempted to obtain CSA storage in which to load an SMF exit module. The name of the SMF exit, the name of the module and the return code from the STORAGE OBTAIN macro instruction are shown in the message. System Action: Processing continues. User Response: Be certain enough stroage is available in the CSA for Strobe Monitoring. STRGM0043E Unable to add SMF exit. Exit name=@@. Module name=@@. Return code =@@. Reason code=@@. Severity: Error Explanation: The Strobe Monitoring main task attempted to add an SMF exit. The attempt failed. The exit name, the module name, and the return and reason codes from the CSVDYNEX macro instruction are shown in the message. System Action: Processing continues. User Response: Be certain the module name shown in the message is in an authorized library available to the MNAS. STRGM0044E Load for module @@ failed. System completion code=@@. Reason co de @@. Severity: Error Explanation: The Strobe Monitoring main task attempted to load a module and the load failed. The name of the module, the system completion code and the reason code are shown in the message. System Action: Processing continues. User Response: Be certain the Strobe authorized library is available to the MNAS, and that the module shown in the messagae is in the library. STRGM0052E Unable to obtain storage for Resource Manager module @@. Return code=@@. Severity: Error Messages Returned by Global Monitoring 4-19 Explanation: The Strobe Monitoring main task attempted to obtain CSA storage in which to load a resource manager module. the name of the module and the return code from the STORAGE OBTAIN macro instruction are shown in the message. System Action: MNAS initialization terminates. User Response: Be certain enough strorage is available in the CSA for Strobe Monitoring. STRGM0100I STOP command received. The MNAS is shutting down. Severity: Informational Explanation: The MVS STOP command was issued to the MNAS. The MNAS has begun the process of termination. System Action: The MNAS begins shutdown. User Response: None. STRGM0101I Posting subtask @@ to shut down. Severity: Informational Explanation: The main task has posted a subtask to shut down. The name of the subtask module is shown in the message. System Action: Processing continues. User Response: None. STRGM0102I Waiting for subtask detach. Severity: Informational Explanation: The main task has posted subtasks to shut down and is waiting for them to terminate. This is a debugging message for Compuware Technical Support personnel. System Action: Processing continues. User Response: None. STRGM0103I Detaching subtask @@. Severity: Informational Explanation: The main task has posted a subtask to shut down. The subtask is now being detached. The name of the subtask module is shown in the message. System Action: Processing continues. User Response: None. STRGM0110E Unsupported MVS console command entered. Supported commands are STOP and MODIFY. Severity: Error Explanation: An unsupported MVS console command was entered. The only MVS console commands supported by the MNAS are STOP and MODIFY. System Action: Processing continues. User Response: Enter a valid MVS command for the MNAS. STRGM0111E Invalid MODIFY command @@ entered. Severity: Error Explanation: An invalid command was issued to the MNAS using the MVS MODIFY command. The invalid command entered is shown in the message. System Action: Processing continues. User Response: Enter a valid MNAS command. STRGM0112I MODIFY command @@ received. Data=@@. Processing component code=@@ . Severity: Informational 4-20 Strobe Messages Guide Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM0113E Unable to obtain storage for the command data buffer. Return code =@@. Severity: Error Explanation: The Strobe Monitoring main task attempted to obtain storage for a command data buffer. The storage request failed. The return code from the STORAGE OBTAIN macro instruction is shown in the message. System Action: Processing continues. User Response: Be certain that sufficient storage is available the MNAS. STRGM0114I Debugging messages have been enabled. Severity: Informational Explanation: The Strobe Monitoring debugging message have been enabled by the GM_DBUG YES command. System Action: Processing continues. User Response: None. STRGM0115I Debugging messages have been disabled. Severity: Informational Explanation: The Strobe Monitoring debugging messages have been disabled by the GM_DBUG NO command. System Action: Processing continues. User Response: None. STRGM0130I Strobe Monitoring utility task initializing Severity: Informational Explanation: The Strobe Monitoring utility task is initializing. System Action: Processing continues. User Response: None. STRGM0131I Strobe Monitoring utility task initialization complete Severity: Informational Explanation: The Strobe Monitoring utility task has completed initialization. System Action: Processing continues. User Response: None. STRGM0132I @@ Processing work queue. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM0137I Requestor's ASCB address @@ is invalid Severity: Informational Explanation: The requestor of services from the Strobe Monitoring utility task passed an ASCB address indicating that it is running in an address space other than the MNAS. The storage at that address was not an ASCB. System Action: The request is not processed. Messages Returned by Global Monitoring User Response: 4-21 None. STRGM0138I Strobe Monitoring for utility task termination in progress Severity: Informational Explanation: The Strobe Monitoring utility task is terminating. System Action: Processing continues. User Response: None. STRGM0139I Strobe Monitoring utility task termination complete return code @ @ Severity: Informational Explanation: The Strobe Monitoring utility task has terminated. The return code is shown in the message System Action: Processing continues. User Response: None. STRGM0140I @@ Processing Global Monitoring REFRESH request. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM0141I @@ R/C from criteria builder=@@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM0500E Unable to obtain storage for 4 hour rolling average service. STO RAGE R/C=@@. Severity: Error Explanation: Strobe Global Monitoring attempted to obtain storage in order to acquire 4 hour rolling average usage information for the LPAR. The attempt to obtain storage failed with the return code shown in the message. System Action: Processing continues. Further attempts to acquire the 4 hour rolling average will be disabled. User Response: Increase the region size for the MNAS. STRGM0510E Undefined return code from REQLPDAT service. R/C=@@. Severity: Error Explanation: Strobe Global Monitoring attempted to acquire 4 hour rolling average usage information for the LPAR. An undefined return code was received from the service. The return code is shown in the message. System Action: Processing continues. Further attempts to acquire the 4 hour rolling average will be disabled. User Response: Contact Compuware Technical Support. STRGM0511I REQLPDAT service: data contained in defined capacity section is n ot valid. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. Attempts to acquire the 4 hour rolling average will be continued at the next interval. User Response: None. 4-22 Strobe Messages Guide STRGM0520I Error sending average CPU service data to data pump R/C=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. Further attempts to acquire the 4 hour rolling average will be disabled. User Response: Contact Compuware Technical Support. STRGM0521I Data sent to GM Data Pump: @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM0522I Uncapped: @@. Capped: @@. Interval: @@. Current: @@. 4-Hour avg.: @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1001I Severity: @@ Informational Explanation: Informational Message. System Action: None. User Response: None. STRGM1002W Severity: @@ Warning Explanation: Warning Message. System Action: None. User Response: None. STRGM1003E Severity: @@ Error Explanation: Error Message. System Action: None. User Response: Review message(s) and perform corractive action. STRGM1004E Severity: @@ @@ Error Explanation: Error Message. System Action: None. User Response: Contact Compuware Technical Support. STRGM1005W Severity: @@ @@ Warning Explanation: Warning Message. System Action: None. User Response: Review parameter requirements. Messages Returned by Global Monitoring 4-23 STRGM1309I Name/Token pair @@ not deleted. Name/Token Callable services r/c =@@. MNAS job name: @@. Severity: Informational Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was not deleted. The name portion of the Name/Token pair, the return code from IBM Name/Token Callable Services and the job name of the monitoring address space (MNAS) are shown in the message. System Action: Processing continues. User Response: None. STRGM1320E Name/Token pair @@ not deleted. MNAS @@ is currently active. Severity: Error Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was not deleted. The MNAS associated with the Name/Token pair is currently active. The name portion of the Name/Token pair and the job name of the MNAS are shown in the message. System Action: Processing continues. User Response: Shut down the MNAS prior to running the Name/Token pair delete utility. STRGM1322I Name/Token pair @@ not found. Name/Token Callable Services r/c @ @. Severity: Informational Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was not found. This is a normal situation if the MNAS has not been active since the last IPL. The name portion of the Name/Token pair and the return code from IBM Name/Token Callable Services are shown in the message. System Action: Processing continues. User Response: If the return code is 4, none. STRGM1328I Name/Token pair @@ deleted. MNAS job name: @@. Severity: Informational Explanation: The Name/Token pair associated with the Strobe Monitoring Address Space was deleted. The name portion of the Name/Token pair and the job name of the Monitoring address space are shown in the message. System Action: Processing continues. User Response: None. STRGM1960E Dynamic @@ error. Return Code @@ ERROR @@ INFO @@ @@ Severity: Error Explanation: Dynamic Allocation encountered an error. System Action: Processing terminates. User Response: None. STRGM1964I Criteria record count for system id @@=@@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1965S Invalid Criteria data set for current release. KEYLEN=@@. Severity: Severe Explanation: An invalid criteria data set for the current release of Strobe Global Monitoring. The key length is shown in the message. System Action: The MNAS terminates. 4-24 Strobe Messages Guide User Response: Run the migration utility to migrate the criteria data set from a previous release to the format required for the current release, and restart the MNAS. STRGM1966I @@ @@ @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1967I @@ @@ @@ @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1968I @@ @@ @@ Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1969I @@ @@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGM1970E Error opening Criteria data set. VSAM r/c=@@. Error=@@. PGM=@@. Severity: Error Explanation: An error occurred opening the Strobe Monitoring criteria data set. The VSAM return code and error code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing terminates. User Response: See the job log for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1971E Error on Criteria File. VSAM req=@@, VSAM r/c=@@, Feedback=@@. PGM=@@. Severity: Error Explanation: An error occurred accessing a Strobe Monitoring criteria data set data record. The VSAM request, return code and feedback code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: Refer to subsequent message for the criteria record keys. STRGM1972I Processing SYSIN input command: @@. Severity: Informational Explanation: The STRGMCRI utility is processing the SYSIN input shown. System Action: Processing continues. User Response: None. Messages Returned by Global Monitoring 4-25 STRGM1973E @@ for @@ request. PGM=@@. Severity: Error Explanation: A common VSAM error occurred accessing a Strobe Monitoring criteria data set data record. The VSAM error and criteria utility command are shown in the message. The entire input record is shown in the associated STRGM1972I message. System Action: Processing continues. User Response: Resolve the error accordingly. STRGM1974E Error closing Global Monitoring VSAM dataset, r/c=@@ Severity: Error Explanation: VSAM dataset was not closed properly. System Action: Abend. User Response: None. STRGM1975E RACF Authorization checking failed. VSAM r/c=@@. Error=@@. PGM=@@. Severity: Error Explanation: RACF denied access to the Strobe Monitoring criteria data set. The VSAM return code and error code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing terminates. User Response: See the job log for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1976S Invalid Criteria data set for current release. KEYLEN=@@. Severity: Severe Explanation: An invalid criteria data set for the current release of Strobe Global Monitoring. The key length is shown in the message. System Action: The criteria file is not updated. User Response: Run the migration utility to migrate the criteria data set from a previous release to the format required for the current release. STRGM1979I Criteria SYSIN data set processing complete, Includes=@@, Exclude s=@@, Programs=@@, Read=@@. Severity: Informational Explanation: All of the criteria input records have been processed. The number of valid includes, excludes, and records read are shown. System Action: Processing terminates. User Response: If the number of includes and excludes added together do not equal the number of records read, check the GMCRERRS output for invalid SYSIN cards. STRGM1980E Error opening Repository data set. VSAM r/c=@@. Error=@@. PGM=@@. Severity: Error Explanation: An error occurred opening the Strobe Monitoring repository data set. The VSAM return code and error code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: See the job log from the MNAS for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1981E Error writing Repository File data record. VSAM r/c=@@. Feedback= @@. PGM=@@. Severity: Error 4-26 Strobe Messages Guide Explanation: An error occurred writing the Strobe Monitoring repository data set data record. The VSAM return code and feedback code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: See the job log from the MNAS for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1982I Repository File Summary successful. DSN=@@. Severity: Informational Explanation: The repository file summery report was successfully produced. The name of the repository data set is shown in the message. System Action: Processing continues. User Response: None. STRGM1990W Unable to add JOB @@ @@ @@ to the MDAT memory object. Severity: Warning Explanation: Strobe was attempting to add a tracking entry for the JOB and STEP or JOB and transaction shown. System Action: Processing continues without tracking the JOB/STEP or JOB/transaction. User Response: Increase the GM_MAXNUM parameter and restart the MNAS. Valid values are 1 to 999999. STRGM1991E Error reading Repository File @@ Control record. VSAM r/c=@@. Feedback=@@. PGM=@@. Severity: Error Explanation: An error occurred reading the Strobe Monitoring repository data set control record. The Repository file number, and the VSAM return code and feedback code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: See the job log from the MNAS for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1992E Error reading Repository File data record. VSAM r/c=@@. Feedback= @@. PGM=@@. Severity: Error Explanation: An error occurred reading the Strobe Monitoring repository data set record. The VSAM return code and feedback code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: See the job log from the MNAS for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1993I MDAT successfully written to the repository data set. Severity: Informational Explanation: Strobe monitoring data was successfully written to the repository data set. System Action: Processing continues. User Response: None. STRGM1994I Repository data set successfully switched to @@. Severity: Informational Explanation: Strobe monitoring data was successfully switched. The DD name of the new repository is shown in the message. System Action: Processing continues. Messages Returned by Global Monitoring User Response: 4-27 None. STRGM1995E Error writing Repository File @@ Control record. VSAM r/c=@@. Feedback=@@. PGM=@@. Severity: Error Explanation: An error occurred writing the Strobe Monitoring repository data set control record. The Repository file number, and the VSAM return code and feedback code are displayed in the message. The name of the program issuing the message is also shown in the message. System Action: Processing continues. User Response: See the job log from the MNAS for the corresponding VSAM messages. If there are no messages, contact Compuware Technical Support. STRGM1996E Invalid Global Monitoring Repository data set name prefix specifi ed Severity: Error Explanation: The value specified in the GM_REPOSITORY_DSN Strobe parameter must be a valid data set name prefix. System Action: Global Monitoring terminates. User Response: parameter. Specify a valid data set name prefix on the GM_REPOSITORY_DSN Strobe STRGM1997E Global Monitoring Repository data set name greater than 38 charac ters Severity: Error Explanation: The Global Monitoring repository data set name is too big. System Action: Global Monitoring terminates. User Response: Create a shorter GM_REPOSITORY_DSN parm. STRGM1998E Global Monitoring Repository data set already in use Severity: Error Explanation: The Global Monitoring repository data set can be used by only one Strobe image running on an LPAR. System Action: Global Monitoring terminates. User Response: Create a separate repository data set for each Strobe running on an LPAR. STRGM1999I Global Monitoring repository data set name @@ Severity: Informational Explanation: This message displays the 44 character Global Monitoring data set name. System Action: Global Monitoring initialization continues. User Response: None. STRGP0001I Strobe Monitoring communication task initialization in progress Severity: Informational Explanation: The Strobe Monitoring communication task is initializing. System Action: Processing continues. User Response: None. STRGP0002I Strobe Monitoring communication task initialization complete Severity: Informational Explanation: The Strobe Monitoring communication task has completed initialization. System Action: Processing continues. User Response: None. 4-28 Strobe Messages Guide STRGP0003I Strobe Monitoring communication task termination in progress Severity: Informational Explanation: The Strobe Monitoring communication task is terminating. System Action: Processing continues. User Response: None. STRGP0004I Strobe Monitoring communication task termination complete return code @@ Severity: Informational Explanation: The Strobe Monitoring communication task has terminated. The return code is shown in the message System Action: Processing continues. User Response: None. STRGP0005I Strobe Monitoring communication task not required. Task terminati ng Severity: Informational Explanation: The Strobe Monitoring communication task is not required because neither GM_SMFDATA=YES nor GM_CICS=YES were specified in the parmlib member used by the MNAS. System Action: The Strobe Monitoring Communication task terminates. User Response: None. STRGP0030E Attach for subtask @@ failed. Return code=@@ Severity: Error Explanation: An attempt to attach a Strobe monitoring task has failed. The name of the program being attached and the return code from the ATTACH macro instruction are shown in the message. System Action: Processing continues. User Response: error. Using the return code shown in the message, determine the cause of the STRGP0031I Subtask @@ has ended. Completion code @@ Severity: Informational Explanation: A subtask has terminated. The name of the attached program and the completion code are shown in the message. System Action: The subtask is reattached. User Response: If the subtask has abended, save any SVC dumps and the log data set from the MNAS, and contact Compuware Technical Support. STRGP0032I Subtask @@ is being reattached Severity: Informational Explanation: A subtask has terminated and is being reattached. System Action: Processing continues. User Response: None. STRGP0033S Subtask @@ has failed and will not be reattached Severity: Severe Explanation: A subtask has terminated with a severe error and has indicated that it should not be reattached. The name of the attached program is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. Messages Returned by Global Monitoring 4-29 STRGP0034S Subtask @@ has terminated @@ times and will not be reattached Severity: Severe Explanation: A subtask has terminated more frequently than allowed. The name of the attached program is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. STRGP0035E Request to restart @@ processing failed. Subtask entry not found Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed due to an error in an internal control block. The name component is shown in the message. System Action: Processing continues. User Response: Contact Compuware Technical support. The MNAS will have to be restarted in order for the subtask to be reinitialized. STRGP0036E Request to restart @@ processing failed. Subtask is active Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed because the component task is still active. System Action: Processing continues. User Response: Ensure that the task has been terminated before attempting to restart it. STRGP0037I Subtask @@ has terminated Severity: Informational Explanation: A subtask has terminated and has indicated that it may be reattached by the RESTART operator command. The name of the attached program is shown in the message. System Action: Processing continues. User Response: If desired, the task may be restarted using the RESTART operator command. STRGP0038E Request to restart @@ processing failed. Subtask is not eligible for restart Severity: Error Explanation: An operator command has been issued to restart a component service task. That request has failed because the component task indicated that it cannot be restarted. System Action: Processing continues. User Response: Contact Compuware Technical Support. STRGP0050E Load for module @@ failed. System completion code=@@. Reason co de @@. Severity: Error Explanation: The Strobe Monitoring communication task attempted to load a module and the load failed. The name of the module, the system completion code and the reason code are shown in the message. System Action: Processing continues. User Response: Be certain the Strobe authorized library is available to the MNAS, and that the module shown in the messagae is in the library. STRGP0051S Unable to obtain storage for @@ data area. Return code=@@. Severity: Severe Explanation: The Strobe Monitoring communication task attempted to obtain storage for a data area. The storage request failed. The name of the data area and the return code from the STORAGE OBTAIN macro instruction are shown in the message. 4-30 Strobe Messages Guide System Action: Processing continues. User Response: Be certain that sufficient storage is available the MNAS. STRGP0052S Unable to attach subtask @@. Return code=@@. Severity: Severe Explanation: The Strobe Monitoring communication task attempted to attach a service subtask. The attach request failed. The module name of the task being attached and the return code from the ATTACH macro instruction are shown in the message. System Action: Processing continues. User Response: Be certain the Strobe authorized library is available to the MNAS, and that the module shown in the messagae is in the library. STRGP0100I @@ successful. Severity: Informational Explanation: The Strobe Monitoring communication task successfully performed the TCP/IP event. System Action: Processing continues. User Response: None. STRGP0101W @@ unsuccessful RETCD=@@ ERRNO=@@ Severity: Warning Explanation: The Strobe Monitoring communication task unsuccessfully performed the TCP/IP event. Return code and ERRNO are displayed. System Action: Processing continues. User Response: Support. Resolve the event using Return code and ERRNO or contact Compuware STRGP0102I @@ @@ @@ Severity: Informational Explanation: The Strobe Monitoring communication task informational message. System Action: Processing continues. User Response: None. STRGP0800I @@ @@ Severity: Informational Explanation: Informational message from STROBE SMF Data Processor. System Action: Processing continues. User Response: None. STRGP0801S @@ @@ Severity: Severe Explanation: System Action: Strobe SMF data processor encountered an error. Processing terminates. User Response: Review the message and correct the error. Restart the job. If the error cannot be identified, contact Compuware support. STRGP0900I @@ Processing work queue. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. Messages Returned by Global Monitoring STRGP0901I @@ Work Queue element address=@@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGP0902I @@ Processing send request. Desination=@@ @@ @@ @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGP0903I @@ Work queue element returned to queue. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGP0904I @@ Terminating subtask @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRGP0905I @@ Detaching subtask @@. Severity: Informational Explanation: This is a debugging message for Compuware support personnel. System Action: Processing continues. User Response: None. STRJP0200I Severity: @@ @@ @@ @@ @@ @@ @@ @@ Informational Explanation: A debugging message written by the JVMTI agent. Content will vary. System Action: Processing continues. User Response: None. STRJP0300I Topaz Java Strobe interface initialization in progress on TCB @@ Severity: Informational Explanation: The Topaz Java Strobe interface task is initializing. System Action: Processing continues. User Response: None. STRJP0301I Topaz Java Strobe interface intialization complete on TCB @@ Severity: Informational Explanation: The Topaz Java Strobe interface task has completed initialization. System Action: Processing continues. User Response: None. 4-31 4-32 Strobe Messages Guide STRJP0302I Topaz Java Strobe interface running in @@ @@ ASID @@ Severity: Informational Explanation: The Topaz Java Strobe interface task has completed initialization and is running in the JOB/STC shown. System Action: Processing continues. User Response: None. STRJP0303I Topaz Java Strobe interface termination in progress on TCB @@ Severity: Informational Explanation: The Topaz Java Strobe interface task is terminating. System Action: Processing continues. User Response: None. STRJP0304I Topaz Java Strobe interface found a name/token with storage at @@ Severity: Informational Explanation: The Topaz Java Strobe interface task found an existing name/token pair and the associated JPAI at the address shown. System Action: Processing continues. User Response: None. STRJP0305I Topaz Java Strobe interface created a name/token, JPAI at @@ Severity: Informational Explanation: The Topaz Java Strobe interface task created a new name/token pair and the associated JPAI is at the address shown. System Action: Processing continues. User Response: None. STRJP0306I Topaz Java Strobe interface returned from NTP delete, r/c=@@ Severity: Informational Explanation: The Topaz Java Strobe interface task attempted to delete the name/token pair and the return code is shown. System Action: Processing continues. User Response: If the return code is not 0 contact Compuware Technical Support. STRJP0310I Topaz Java Strobe interface releasing JPAI at @@ Severity: Informational Explanation: shown. The Topaz Java Strobe interface task is releasing the JPAI storage at the address System Action: Processing continues. User Response: None. STRJP0311I Topaz Java Strobe interface leaving JPAI at @@ Severity: Informational Explanation: The Topaz Java Strobe interface task has been posted to terminate while a Strobe measurement was in progress, so JPAI is being left behind for Strobe to use. If the meaured address space is not terminating it will be retrieved for re-use upon the next agent initialization. System Action: Processing continues. User Response: None. Messages Returned by Global Monitoring 4-33 STRJP0320I Topaz Java on TCB @@ posted to @@ for Strobe request @@ Severity: Informational Explanation: The Topaz Java Strobe task has been posted to process a request from Strobe, and the request number is shown. System Action: Processing continues. User Response: None. STRJP0321I Topaz Java requested to sample @@ times over @@ minutes by Strobe r equest @@ Severity: Informational Explanation: The Topaz Java Strobe task has been posted to process a sample from Strobe, and the request number, sample count, and sample time in minutes is shown. System Action: Processing continues. User Response: None. STRJP0322I Topaz Java entering WAIT on TCB @@ last request @@ Severity: Informational Explanation: The Topaz Java Strobe task is entering a WAIT with the task address and previous Strobe request shown. System Action: Processing continues. User Response: None. STRJP0323I Topaz Java entering WAIT, last request @@ Strobe request @@ Agent r /c=@@ Severity: Informational Explanation: The Topaz Java Strobe task is entering another WAIT, and the previous Strobe request and request number are shown along with the Agent return code for that request. System Action: Processing continues. User Response: None. STRJP0330I Topaz Java Strobe interface on TCB @@ posted to terminate Severity: Informational Explanation: The Topaz Java Strobe task has been posted to terminate at JVM termination. System Action: Processing continues. User Response: None. STRJP0800S Abend @@ occurred in module @@ Severity: Severe Explanation: The named module experienced an abend during the processing listed. The abend code is also listed. This message is the first in a series of messages. System Action: Processing terminates. User Response: Review the JES message log for additional error messages that might have been issued. Refer to subsequent messages for additional information and contact Compuware Technical Support. STRJP0801I PSW at entry to abend @@-@@ ILC @@ INTC @@ Severity: Informational Explanation: This message lists the PSW at entry to the abend listed in the previous STRJP0800S message. This message is the second in a series of messages. System Action: Processing terminates. User Response: Review the JES message log for additional error messages that might have been issued. Refer to subsequent messages for additional information and contact Compuware Technical Support. 4-34 Strobe Messages Guide STRJP0802I GPR @@ @@ @@ @@ @@ Severity: Informational Explanation: This message lists four of sixteen general purpose registers at the time of the abend, and repeats four times. User Response: Review the JES message log for additional error messages that might have been issued. Refer to subsequent messages for additional information and contact Compuware Technical Support. STRJP0803I GPR @@ @@ @@ @@ @@ Severity: Informational Explanation: This message lists four of sixteen 64bit general purpose registers at the time of the abend, and repeats four times. It appears ONLY if the abending module was in AMODE64. User Response: Review the JES message log for additional error messages that might have been issued. Refer to subsequent messages for additional information and contact Compuware Technical Support. 5-1 Chapter 5. sAbend Codes Returned by Strobe Chap 5 Measuring with Strobe does not affect the execution of the target program. Strobe causes a measured step to terminate abnormally only when the user program itself has terminated abnormally. When a measurement task module abnormally terminates, Strobe writes abnormal termination information to the sample dataset. The session management facility writes abnormal termination data to the Strobe log and to its SYSPRINT dataset. Strobe Programmed Terminations Under certain circumstances, the measurement task can terminate with a programmed abnormal termination. User programs are not affected. When you receive any of the abnormal termination (ABEND) codes listed below, note the ABEND code number and inform the Strobe system programmer of the problem. ABEND Code Reason for the Measurement Task ABEND 0000 Strobe issued an ABEND during measurement initialization. 0001 Strobe issued an ABEND request to the measurement task. 0002-4 The measurement task detected an internal error in the ADB chain. The reason code identifies the specific location. 0002-8 The measurement task detected an internal error in the ADB chain. The reason code identifies the specific location. 0002-12 The measurement task detected an internal error in the ADB chain. The reason code identifies the specific location. 0002-16 The measurement task detected an internal error in the ADB chain. The reason code identifies the specific location. 0003 The measurement task detected an internal error in the ADB chain. 0100 The release level of the session management facility is earlier than the release level of the measurement task. 0101 The release level of the measurement task and the release level of the session management facility are incompatible. 0103 The user attempted to invoke the measurement facility through STRBVPH1. 0322-10 The measurement task used an excessive amount of time; there may be a loop in the program. The reason code indicates that the timeout occurred during measurement initialization and sample file open. 0322-20 The measurement task used an excessive amount of time; there may be a loop in the program. The reason code indicates that the timeout occurred during sampling. 5-2 Strobe Messages Guide ABEND Code Reason for the Measurement Task ABEND 0322-30 The measurement task used an excessive amount of time; there may be a loop in the program. The reason code indicates that the timeout occurred during measurement termination and sample file close. 0522 The measurement task used an excessive amount of elapsed time; there may be a hang in the program The session management facility also issues ABEND codes. Conditions that can cause these abnormal terminations include: • A program that was not part of the Strobe system attempted to use the session management facility. • The program being measured damages the measurement task or its working storage (both located in the target program’s address space). • The operating system malfunctions. The session management facility uses ABEND codes for all programmed ABENDs and shows the ABEND code with the termination message. These codes take the form 6xx. The reason code is represented as the hexadecimal equivalent of the value. ABEND and Reason Code Reason for the Session Management Facility ABEND 610-0 An ENV test command was issued. 610-1 ISPF and session requester releases are incompatible. 610-2 Call to session requester is invalid. 610-4 BLDL failed for the module. 610-5 Strobe could not locate the module. 610-6 Strobe detected an internal error while processing a parameter list. 610-7 Strobe detected an internal error while processing a request. 610-8 Strobe detected an internal error while processing an ENV REMOVE request. 610-9 Open failed for the SYSQUEUE dataset. 610-F Strobe experienced a failure issuing the SVCUPDTE service or ENQ service. 610-10 Strobe detected an internal error while searching an SVC table. 610-11 Strobe detected an internal error in parser; the reason code identifies the specific location of the error. 610-12 Strobe detected an internal error in parser; the reason code identifies the specific location of the error. 610-14 Strobe detected an internal error in parser; the reason code identifies the specific location of the error. 610-18 System service QEDIT failed during started task initialization. 611-0 Session requester terminated because the operator pressed the ATTN key. 611-1 Session requester terminated as part of session manager ABEND processing. 620-1 Versions of STRBCPH0 and STRBCLPA are incompatible. 620-2 Attach of user’s program failed. 620-3 System service BLDL failed. Abend Codes Returned by Strobe 5-3 ABEND and Reason Code Reason for the Session Management Facility ABEND 620-4 Strobe detected an internal error; the reason code gives the specific location of the error 620-5 Strobe detected a serialization error during measurement task initialization. 620-6 Strobe attempted to attach the session requester as a subtask and this attach failed. 630-0 Versions of STRBCLPA and STRBCRB are incompatible. 650-0 An invalid entry code passed to the Strobe SVC, or the Strobe SVC was called by an unauthorized user. 650-1 Invalid SRE address passed to the Strobe SVC. 650-2 Invalid parameter passed to the Strobe SVC message function. 650-3 Cross-memory post failed during a SEND command while the session manager was trying to post the measurement task. 650-4 Cross-memory post failed during POST processing while trying to post the session manager or the session requester. 650-5 Cross-memory post failed during end-of-task exit processing while the session manager or the session requester was trying to post STRBCSM or STRBCSR. 650-6 SVC ABEND, Strobe detected an internal error in DELETE function. 650-7 SVC ABEND, Strobe detected an internal error in SEND function. 650-8 SVC ABEND, Strobe detected an internal error in SEND function. 650-9 SVC ABEND, Strobe detected an internal error in SEND function. 650-A SVC ABEND, Strobe detected an internal error in SEND function. 650-B STRBCXAC error calling exit 650-C Internal error building MSCB 650-D Strobe detected an invalid OUCB. 650-E Invalid parameter passed to Strobe SVC sign-on function. 650-F Invalid parameter passed to Strobe SVC sign-on function. 650-10 Strobe detected an internal error in SWAREQ processing. 660-0 SRB ABEND, cross-memory post failed. 670-0 IRB ABEND, cross-memory post failed. 700-8 Sysevent transwrap failed. 700-12 Cross-memory post of session manager failed 700-22 Attach of AutoStrobe subtask failed 701-1 Timer failure 701-3 AutoStrobe work area unavailable. 777-2 Cross-memory post of Measurement Services Address Space (MSAS) failed. Table 5-1 lists Strobe SSAREQ return codes, reason codes, and meaning/action for each. Table 5-1. SSAREQ Return Codes and Reason Codes Return Codes Reason Codes Meaning/Action IfiRcOk EQU X'00' Rc00 Normal 5-4 Strobe Messages Guide Table 5-1. SSAREQ Return Codes and Reason Codes Return Codes Reason Codes Meaning/Action IfiRcWrn EQU X'04' Rc04 Warning IfiRwxxx EQU X'ff' wRsn model IfiRcErr EQU X'08' Rc08 Error IfiReFnc EQU X'04' 04 eRsn Function code invalid/unsupp. IfiReIns EQU X'08' 08 eRsn No Ift slots avail IfiReInf EQU X'0C' 12 eRsn No match on IftAs IfiReInA EQU X'10' 16 eRsn Subtask Attach failed IfiReCmd EQU X'14' 20 eRsn #IfiCCmd invalid IfiReSal EQU X'18' 24 eRsn SALSAWT invalid IfiRcLog EQU X'0C' Rc12 Logic error IfiRlSno EQU X'04' 04 nRsn FIFA/M Internal ShowNotOccur IfiRlRat EQU X'08' 08 nRsn FIFA 1st call must be #IfiCtIi IfiRlxxx EQU X'ff' lRsn model IfiRcEnv EQU X'10' Rc16 Environment IfiRnIpr EQU X'04' 04 nRsn INPUT PARM AREA NOT ACCESABLE IfiRnStg EQU X'08' 08 nRsn STORAGE OBTAIN FAILED TOKEN AREA IfiRn0C EQU X'0C' 12 nRsn STORAGE OBTAIN FAILED LCL BFR IfiRn10 EQU X'10' 16 nRsn SSA NO DB2 Act (SALSIB=0) IfiRn14 EQU X'14' 20 nRsn SSA NO DB2 Act (SIBDACC=0) IfiRnDWL EQU X'18' 24 nRsn LOAD fail DB2 RRSAF/CAF Intf IfiRnDW2 EQU X'1C' 28 nRsn LOAD fail DB2 WLIR/WLI2 Intf IfiRn20 EQU X'20' 32 nRsn DB2 CAF CONNECT FAILURE IfiRn24 EQU X'24' 36 nRsn DB2 CAF OPEN FAILURE IfiRn28 EQU X'28' 40 nRsn UNABLE TO UPDATE SSA SIB IfiRn2C EQU X'2C' 44 nRsn INTERNAL IFI BUFFER NOT PRESENT IfiRn30 EQU X'30' 48 nRsn INVALID DAB CONTROL BLOCK IfiRnIrf EQU X'34' 52 nRsn IFI READS FAILURE IfiRnNiu EQU X'38' 56 nRsn IftU zero IfiRnRid EQU X'40' 64 nRsn RRSAF Identify err IfiRnRsn EQU X'44' 68 nRsn RRSAF Signon Err IfiRnWdt EQU X'48' 72 nRsn WLI Dis Trace err IfiRnWst EQU X'4C' 76 nRsn WLI Sta Trace err IfiRnAbn EQU X'50' 80 nRsn FIF* SubT unexpected term IfiRnEnq EQU X'54' 84 nRsn FIF0 Enq failed IfiRnDeq EQU X'58' 88 nRsn FIF0 Deq failed IfiRnSoq EQU X'5C' 92 nRsn FIF0 Stor Obt DsEndDs failed IfiRnSrq EQU X'60' 96 nRsn FIF0 Stor Rel DsEndDs failed IfiRnSri EQU X'64' 100 nRsn FIF0 Stor Rel #IFI failed IfiRnSaw EQU X'68' 104 nRsn FIFA SAW failed validity ck Abend Codes Returned by Strobe Table 5-1. SSAREQ Return Codes and Reason Codes Return Codes Reason Codes Meaning/Action IfiRnHot EQU X'F00' nRsn HotReason-testing e.g. dcb open Function Codes Returned by Strobe Session Manager When function codes appear in error messages, they provide additional information about the state of Strobe Session Manager when the error occurred. This diagnostic information can be helpful in troubleshooting errors that Strobe may encounter. Function Code returned by Strobe Session Manager Definition of the Function Code 10 Terminates a request 12 Checks Queue space 14 Obtains a request number 15 Shows XCF Group members 16 Calls task mode receiver 17 Collects XCF Group parameters 18 Strobe Request Element update facility 20 Deletes dummy Queue record 21 Calls the Group Configuration Manager 22 Activates the Attach Filter Request 23 RESYNC Command 32 ADD QUEUED (phase 1) 33 ADD QUEUED (phase 2) 34 CHANGE QUEUED (phase 3) 35 CHANGE QUEUED (phase 2) 36 DISPLAY (phase 1) 37 DISPLAY (phase 2) 38 ADD QUEUED (phase 3) 39 Reads module tracking record (MTTR) 48 ADD ACTIVE (phase 1) 49 ADD ACTIVE (phase 2) 50 ADD ACTIVE (phase 3) 51 SEND (phase 1) 52 SEND (phase 2) 53 SEND (phase 3) 54 CHANGE ACTIVE (phase 1) 55 Initiates Queued Request Element Build/Write/Broadcast 64 Error in processing message from member 65 Message in response to internal Strobe command 66 Error processing internal Strobe command 67 Internal Delete (phase 1) 5-5 5-6 Strobe Messages Guide Function Code returned by Strobe Session Manager Definition of the Function Code 68 Internal Delete (phase 2) 69 Strobe Request Element Update Facility (phase 1) 70 Strobe Request Element Update Facility (phase 2) 72 CHANGE ACTIVE (phase 2) 73 CHANGE ACTIVE (phase 3) 80 DELETE (phase 2) 81 DELETE (phase 3) 82 DELETE (phase 4) 83 Initializes Timer Queue 84 Strobe Expiration Check 86 Reads Messages Service 87 Task-Mode Receiver (phase 2) 88 Synchronous return to Session Requester (ADD QUEUED) 89 Synchronous return to Session Requester (CHANGE QUEUED) 96 ADD GROUP 97 CHANGE GROUP 98 LIST GROUP 99 DELETE GROUP 100 SUBMIT GROUP 113 AutoStrobe Scheduling 114 Internal ADD ACTIVE (phase 1) 115 Internal ADD ACTIVE (phase 2) 116 Internal ADD ACTIVE (phase 3) 117 Internal SEND (phase 1) 118 Internal SEND (phase 2) 119 Internal SEND (phase 3) 120 AutoStrobe Concurrent ADD (phase 1) 121 AutoStrobe Concurrent ADD (phase 2) 128 Session Manager internal NOP function 129 AutoStrobe Scheduling 130 Marks Strobe Request Element complete (phase 1) 131 Marks Strobe Request Element complete (phase 2) 132 AutoStrobe Concurrent ADD (phase 3) 144 Creates Auto Profile (phase 1) 145 Creates Auto Profile (phase 2) Abend Codes Returned by Strobe 5-7 ABEND Codes Returned by the Strobe SQL Agent This section describes ABEND codes returned by the Strobe SQL agent when it encounters an unrecoverable error. The system ABENDs the Strobe SQL Agent. Reason codes for all errors are saved in register 15. For all errors, respond to any messages issued to the console or the job log and for any accompanying system ABENDs. See the descriptions of the Strobe SQL Agent ABEND codes for suggestions. If the problem persists, contact Compuware Customer Support and provide the following documentation: • • • • All printed output and output datasets related to the problem The JCL for the job. The Logrec dataset error record A copy of the system dump dataset if available. ABEND Code Issuing module Reason Code and Explanation System Action Programmer response U0300 STRBAGNT (the Strobe SQL Agent) 00080004 Job step was not APF-authorized. Ensure that the Strobe SQL Agent is running from an APF-authorized load library. 00080008 An internal error was detected. Contact Compuware Customer Support. 0008000C Possible attempt to start Strobe SQL Agent from the system console. Do not attempt to start the Strobe SQL Agent from the system console; it may only be started by the Strobe session manager. 00080010 Unable to load STRBSFR0. Ensure that all necessary Strobe modules are present in the load library. 00080014 Unable to load STRB2RMI. Ensure that all necessary Strobe modules are present in the load library. 00080018 Unable to load STRBGBES. Ensure that all necessary Strobe modules are present in the load library. 0008001C Unable to load STRB2RM0. Ensure that all necessary Strobe modules are present in the load library. 00080020 Unable to load STRBFTBL. Ensure that all necessary Strobe modules are present in the load library. 00080024 Unable to load STRBFxxx. Ensure that all necessary Strobe modules are present in the load library. 00080028 Unable to load STRBSRMD. Ensure that all necessary Strobe modules are present in the load library. 0008002C An internal error was detected. Contact Compuware Customer Support. 5-8 Strobe Messages Guide ABEND Code Issuing module Reason Code and Explanation System Action Programmer response 00080030 An internal error was detected. Contact Compuware Customer Support. 00080038 Unable to load STRBSRM0. Ensure that all necessary Strobe modules are present in the load library. 0008003C Unable to load STRB2RMD. Ensure that all necessary Strobe modules are present in the load library. 00080040 Unable to load STRBARM0. Ensure that all necessary Strobe modules are present in the load library. 000Cxxxx  An internal error was detected. Contact Compuware Customer Support. 00100004 Unable to allocate work area. Retry the request. 0010004C Strobe SQL Agent unable to communicate with Strobe Session Manager. Recycle Strobe to ensure the Strobe Session Manager initialization has already occurred when the Strobe SQL Agent is starting. 00100008 00100078 An internal error was detected. Contact Compuware Customer Support. U0301 STRBSFR0 000C0004 Unsupported function code. The system Ensure that all Strobe ABENDs the caller. modules have been installed at the same maintenance level. U0302 STRBARM0 000C0004 An internal error was detected. Operation continues. U0303 SSASQLI0 00100004 An internal error was detected. The system Contact Compuware ABENDs the caller. Customer Support. U0304 STRB2RMI 000C0004 An internal error was detected. The system Contact Compuware ABENDs the caller. Customer Support. U0305 STRBSRM0 000C0004 An internal error was detected. The system Contact Compuware ABENDs the caller. Customer Support. U0400 STRBFIFR 000C0004 Storage obtain for working storage failed. The SQL Collector subtask is terminated. Contact Compuware Customer Support. Check to see if the SQL Agent Procedure has REGION=0M. If not, change it, restart Strobe, and try again. If it does, contact Compuware Customer Support. Abend Codes Returned by Strobe ABEND Code Issuing module Reason Code and Explanation System Action Programmer response 000C0008 Unable to get Strobe control blocks. The SQL Collector subtask is terminated. Contact Compuware Customer Support. 000C000C Load of IFI parms module STRBFIFP failed. The SQL Collector subtask is terminated. Contact Compuware Customer Support. 000C0010 Insufficient DB2 Authorization. The SQL Collector subtask is terminated. Check to see if the authorizations grants in STRBSAMP member STRBGRNT were given to the SQL Agent. If not, grant them, restart Strobe, and try again. If they have been granted, contact Compuware Customer Support. 000C0014 The SQL Collector Getmain for buffer subtask is terminated. prefixes storage failed. Check to see if the SQL Agent Procedure has REGION=0M. If not, change it, restart Strobe, and try again. If it does, contact Compuware Customer Support. 000C0018 Strobe DB2 SQL IFI Check to see if the SQL Getmain for buffer trace collection is Agent Procedure has storage failed. terminated. REGION=0M. If not, change it, restart Strobe, and try again. If it does, contact Compuware Customer Support. 000C001C IFI initialization failed. Strobe DB2 SQL IFI Check the SQL Agent trace collection is Procedure log for any DB2 terminated. messages. If no DB2 messages are present, contact Compuware Customer Support. 000C0020 Unable to obtain trace user class. Strobe DB2 SQL IFI Check the SQL Agent trace collection is Procedure log for any DB2 terminated. messages. If no DB2 messages are present, contact Compuware Customer Support. 000C0024 Unable to format DB2 Start Trace command. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0028 DB2 Async IFI command failed. Strobe DB2 SQL IFI Check the SQL Agent trace collection is Procedure log for any DB2 terminated. messages. If no DB2 messages are present, contact Compuware Customer Support. 5-9 5-10 Strobe Messages Guide ABEND Code Issuing module Reason Code and Explanation System Action Programmer response 000C0030 Internal SETTMR routine failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0034 Internal STIMERM cancel failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0038 Internal timer pop service routine failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C003C Internal DB2 TERM service routine failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0040 Internal Control events service routine failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0044 IFI buffers exhausted. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0048 Internal SETTMR service routine failed. Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. terminated. 000C0054 Strobe DB2 SQL IFI Contact Compuware Internal PTBUIP trace collection is Customer Support. routine unable to terminated. obtain buffer lock. 000C0058 Strobe DB2 SQL IFI Contact Compuware trace collection is Customer Support. Internal GTBUIP terminated. routine unable to obtain buffer lock. U0400 U0401 U0500 STRBFSS0 STRBFUS0 STRBFIFM 00100004 Unable to allocate work area. The system Retry the request. ABENDs the caller. 00100008 An internal error was detected. An internal error was detected. Retry the request. 0010000C An internal error was detected. An internal error was detected. Contact Compuware Customer Support. 000C0004 An internal error was detected. The system Contact Compuware ABENDs the caller. Customer Support. 00100004 Unable to allocate work area. The system Retry the request. ABENDs the caller. Any RC DB2 trace terminates Contact Compuware Customer Support.