Preview only show first 10 pages with watermark. For full document please download

Studio Installation Instructions 2590.101

   EMBED


Share

Transcript

STUDIO Monoblock Lavatory Faucet with Speed Connect™ Drain Installation Instructions 2590.101 Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect Drain* • Fewer parts, installs in less time • Never needs adjustment • Guaranteed to seal properly the first time, every time. Certified to comply with ANSI A112.18.1 *Your new American Standard faucet is designed to work only with the Speed Connect drain. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. M968626 REV.1.4 Recommended tools Screwdriver 1 INSTALL FAUCET CAUTION Channel Locks Adjustable Wrench Turn off hot and cold water supplies before beginning. Seat SEAL (1) into under side of FAUCET BASE (2). Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN CABLE ASSEMBLY (8) through the mounting hole of lavatory or mounting surface. Fig. A. From below, push GASKET (7) and RETAINING WASHER (5) onto MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6), pulling faucet to front of sink, so SUPPLIES (3) rests against mounting hole. Before final tightening, make sure collar on MOUNTING NUT (6) is seated into RETAINING WASHER (5). Fig. B. Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6) to complete faucet mounting. Fig. A. 2 GROOVE (FAUCET BASE) 4 MOUNTING SURFACE Fig. B. 8 COLLAR ON MOUNTING NUT 7 5 6 4 1 1 3 2 POP-UP DRAIN Fig. A. Fig. B. Remove CLEAR PLASTIC COVER (1). 1 Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). 3 DRAIN BODY Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B. 2 3 REMOVE FLANGE 4 Fig. A. Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A. Fig. B. 1 Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B. 4 INSTALL DRAIN FROM BELOW FIXTURE From under side of SINK install DRAIN BODY (1) up through drain outlet. Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK. REAR OF SINK 4 5 3 TIGHTEN LOCKNUT Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks. DRAIN OUTLET 3 FLANGE GASKET AND POP-UP KNOB 1 1 Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly. 6 4 2 2 Fig. A. Fig. B. Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A. POP-UP KNOB (1) must be fully down. Fig. B. DOWN 1 WHITE FOAM GASKET NOT VISIBLE DRAIN FLANGE M968626 REV.1.4 2 7 ATTACH CABLE CONNECTOR Fig. A. Fig. B. Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A. 1 Your new POP-UP DRAIN installation is now complete. Fig. B. Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. B. 2 8 1-1/4” O.D. CHECK OPERATION OF POP-UP Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. 1 Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions. 2 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting supplies are 3/8" compression. Connect left SUPPLY (1) to Hot (Marked with a Red Band) and right supply to COLD (2) wall supply. 1 Faucet supplies are 20" long from faucet base. Note: If additional supply length is required, installer must purchase additional parts separately. Important: If SUPPLY HOSES (1, 2) are to long, loop as illustrated to avoid kinking. Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet. APPROX. 20" 2 1 RED BAND HOT BLUE BAND 3/8" COMPRESSION COLD M968626 REV.1.4 3 10 ON TEST INSTALLED FITTING 1 OFF COLD With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks. HOT Remove AERATOR (3). 4 Operate HANDLE (1) to flush water lines thoroughly. Replace AERATOR (3). 3 CHECK DRAIN CONNECTIONS Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions. 5 Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary. WASTE OUTLET 2 2 11 SERVICE CAUTION Turn off hot and cold water supplies before beginning. To remove or replace cartidge: Turn valve to OFF position. +HOTTER Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2). Pull off HANDLE (3) and CAP (4). Unthread CARTRIDGE NUT (5) and remove. Pull out CARTEIDGE (6). COLDER Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean if necessary. Clean MANIFOLD (8) and rinse clean. Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8). 9 Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3). If spout drips, operate handle several times from OFF to ON and 10 HOT to COLD position. Do not force - handle turns only 90˚. ADJUST HOT LIMIT SAFEYT STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (9) reduces risk of accidental scalding. To lower the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (9). Note: The HOT LIMIT SAFETY STOP (9) is set at the maximum hot temperature setting from the factory. Fig. A. 10 SETTING MARKS A 3 1 2 2.5mm HEX KEY 4 REMOVE INSTALL GEAR B 5 10 9 GEAR C 9 6 10 To adjust HOT LIMIT SAFETY STOP: Remove HANDLE ASSEMBLY (3), CAP (4) and CARTRIDGE NUT (5). Set the CARTRIDGE STEM (10) to the OFF position and rotate it 9 clockwise until stops. Fig. B. Rotate the CARTRIDGE STEM (10) counter-clockwise to a colder setting mark in the HOT LIMIT SAFETY STOP (9). Fig. C. Lift up the HOT LIMIT SAFETY STOP (9) and rotate it to coincide again with the stop in the base of the CARTRIDGE STEM (10). Fig. D. Replace the HOT LIMIT SAFETY STOP (9). Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3). 12 “P” TRAP 7 GEAR D 8 GEAR CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. M968626 REV.1.4 4 Speed Connect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: • Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: • Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: • Follow STOPPER REMOVAL PROCEDURE. If you would like the ability to remove your Stopper simply by lifting it out of the drain: • Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” in the illustration. Fig. B. Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C. Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C. Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the Drain Body Connection (2) and hand-tighten. Fig. A. Fig. A. Fig. B. Fig. C. DOWN CAM 1 RE-ATTACH 1 CAM CAP STOPPER DISCONNECT 2 STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B. Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D. Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E. The Stopper can now be removed by lifting it out of the Drain. Fig. F. Fig. D. Fig. E. REMOVE CAM Fig. F. REMOVE CAM CAP M968626 REV.1.4 5 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable). Locked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G. To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G. Fig. G. LOGO Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. LOOP TOWARD REAR OF SINK Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K. DRAIN Locked Mode (Vandal Proof) Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable. Unlocked Mode: Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H. To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down. Fig. H. Fig. H. LOGO 180˚ Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J. LOOP TOWARD FRONT OF SINK Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K. DRAIN Unlocked Mode Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in “Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable. Fig. J. CAM INSTALL CAM Fig. K. INSTALL CAM CAP M968626 REV.1.4 6