Preview only show first 10 pages with watermark. For full document please download

Submital

   EMBED


Share

Transcript

Submittal Data: DCS601A72 DIII-NET Plus Adapter Job Name: Purchaser: Engineer: Submitted To: Submitted By: Unit Designation: Schedule #: Location: For: Reference Date: Model No.: Approval Construction Power: Power supply (externally supplied) Power consumption 24VAC, 60Hz ± 10% 5 W maximum (transformer should be over 20 VA) Operating conditions: Surrounding temperature Humidity (% Relative) Dimensions (H x W x D) Enclosure 14° F to 104° F 20% to 90% (non-condensing) 7-15/32" x 6-3/16" x 1-21/32" Stainless Steel Maximum number of indoor units Maximum number of groups Maximum number of outdoor units 128 64 10 Communication functions: Dlll-NET x 1 RS232C AC equip. communication line Interface to I-Touch Controller Input terminals: F1-F2 x 1 Pulse input Pi x 3 (for PPD option) Certifications: Interference (EMC) DIII-Net connection to VRV outdoor units 1 pulse at 1 or 10 kWh and 40-400 ms FCC Part 15 Subpart B Class A Standard Features: • • • • Doubles the equipment capacity of the I-Touch Controller Adds three pulse inputs (Pi) for PPD applications Includes (1) 32-foot RS232C I-Touch connector cable One year warranty SPECIFICATIONS OF COMMUNICATIONS CABLING (DIII-NET) 2-conductor, stranded, non-shielded TYPE copper cable / PVC or vinyl jacket SIZE AWG18-2 TOTAL LENGTH Options: • • Digital Input (DEC101A51-US) for monitoring of external equipment operation and alarm status Digital Input / Output (DEC102A51-US) for controlling / monitoring of external equipment Configuration and engineering for each project are necessary. Maximum wiring distance between units: 3,280 ft Maximum wiring length: 6,550 ft. SPECIFICATIONS OF POWER METER CABLING (Power Proportional Distribution) 2-conductor, stranded, non-shielded TYPE copper cable / PVC or vinyl jacket SIZE AWG18-2 per input TOTAL LENGTH 492 ft. per input The Power Proportional Distribution (PPD) feature supplies the user with a reasonably calculated apportionment of the total power consumption by the Daikin air-conditioning system to individual units on the system. Because input to the PPD includes measured pulses in the refrigerant system and because the air-conditioning system includes a number of variables, including operating temperatures and pressures, piping length, heat exchange rates and others, no meter-type apportionment of individual users’ consumption can be made. However, the PPD feature provides an apportionment methodology that uses highly advanced technology as applied to the many variables in an air-conditioning system. D a i k i n AC ( Am e r i c a s ) , I n c . ♦ 1 6 4 5 W a l l a c e D r i ve – S u i t e 1 1 0 ♦ C a r r o l l t o n , T X 7 5 0 0 6 SDS DCS601A72 7-08 www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)