Submittal

   EMBED


Share

Transcript

Submittal C 260 Boiler Control 260 01/11 HVAC Systems Replaces: New Job ___________________________ Contact_ _______________________ Designer_ ______________________ The Boiler Control 260 is designed to operate a single boiler using outdoor reset. It can be used in applications ranging from baseboard or mixed radiant heating systems, to combination space heating and domestic hot water heating installations. This control regulates a single heating water temperature through outdoor reset and/or Domestic Hot Water control. It is capable of controlling a single on/off boiler and can receive both space heating and/or DHW heat demands. Front View Side View OCC Terminal Unit Fire Delay 6–5/8” (170 mm) Boiler Demand DHW Demand To increase or decrease the building temperature: Press the Item, , buttons simultaneously for  sec. to enter the ADJUST menu Use the , buttons to adjust the ROOM setting DHW Priority DHW Valve Advanced DHW during UnOcc Return Installer DHW Pump Off Off installer instructions Display defaults back to VIEW menu after 20 sec. Item Test ROOM - Set to desired room temp. OUTDR DSGN - Set to coldest (design) outdoor temp. Terminal Unit Set to High Mass Radiant  Low Mass Radiant 2 Fan Coil 3 Convector 4 Radiator 5 Baseboard 6 Refer to brochure for more information Made in Canada by tekmar Control Systems Ltd. tektra 90-0 Boiler Control 260 C One Stage Boiler & DHW  2 3 4 5 6 7 8 Boiler Demand DHW Demand Power L N Boil P1 N 9 0  2 DHW Pmp/Vlv Boiler 7/8” (23 mm) CL CL uS Meets Class B: Canadian ICES FCC Part 15 Power: 20V + 0% 50/60 Hz 300 VA Relays: 240V (ac) 0 A /3 hp Demand: 20 to 260 V (ac) 2 VA Date Code °F 1/2” (13 mm) Do not apply power 3 4 5 6 7 8 Uno Com Boil Out Com Indr Sw Signal wiring must be rated at least 300V. H54D VieW BOil Mounting Base 1/2” (14 mm) 1–7/8” (49 mm) 7–5/8” (193 mm) 2–7/8” (72 mm) Ø 3/16” (5 mm) 1/2” Knock-out (x 5 back) (x 5 bottom) Specifications------------------------------------------------------ Energy Saving Features-----------Boiler Control 260 One Stage Boiler & DHW Literature Control Packaged weight Dimensions Enclosure Approvals Ambient conditions Power supply Relays Demands Sensors –Included –Optional Warranty D260, A260, D001, D070 Microprocessor control. This is not a safety (limit) control 3.0 lb. (1340 g) 6-5/8” H x 7-9/16” W x 2-13/16” D (170 x 193 x 72 mm) Blue PVC plastic, NEMA type 1 CSA C US, meets class B: ICES & FCC Part 15 Indoor use only, 32 to 113°F (0 to 45°C), RH ≤90% Noncondensing 120 V (ac) ±10%, 50/60 Hz, 1300 VA 240 V (ac) 10 A, 1/3 hp 20 to 260 V (ac) 2 VA NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 Outdoor Sensor 070 and Universal Sensor 082 tekmar type #: 033, 076, 077, 084 Limited 3 Year (See D260 for full warranty) • • • • • Outdoor Temperature Reset Indoor Temperature Feedback (optional) Setback input for energy savings Warm Weather Shut Down Automatic Boiler Differential Additional Features---------------• Quick setup for easy installation and programming of control • User comfort adjustment to increase or decrease building space temperature • Advanced settings to fine-tune building requirements • Pump and valve exercising • Powered boiler pump output • DHW pump or valve operation • Optional DHW priority • Test sequence to ensure proper component operation • 120 V (ac) power supply Special requirements N/A www.tekmarcontrols.com  of 2 © 2011 C 260 - 01/11 Sample Application Drawing Below is a sample application drawing for this product. This application may include other tekmar products that are required for installation. More sample applications can be found at www.tekmarcontrols.com. Sample Mechanical diagram 260 S3 084 070 S2 A1 P2 S1 B1 P1 For zoning solutions by tekmar visit www.tekmarcontrols.com Sample Electrical diagram Legend: °F OCC Terminal Unit Fire Delay Boiler Demand DHW Demand Press the Item, , buttons simultaneously for 1 sec. to enter the ADJUST menu Use the , buttons to adjust the ROOM setting DHW during UnOcc Return Installer DHW Pump Off Off Installer Instructions Display defaults back to VIEW menu after 20 sec. Item Test ROOM - Set to desired room temp. OUTDR DSGN - Set to coldest (design) outdoor temp. Terminal Unit Set to High Mass Radiant 1 Low Mass Radiant 2 Fan Coil 3 Convector 4 Radiator 5 Baseboard 6 Refer to brochure for more information Meets Class B: Canadian ICES FCC Part 15 Made in Canada by tekmar Control Systems Ltd. tektra 910-01 Boiler Control 260 C One Stage Boiler & DHW 1 2 3 4 5 6 7 8 Boiler Demand DHW Demand Power L N Boil P1 9 10 11 12 DHW Pmp/Vlv N Boiler US Power: 120V + 10% 50/60 Hz 1300 VA Relays: 240V (ac) 10 A 1/3 hp Demand: 20 to 260 V (ac) 2 VA Date Code VIEW BOIL DHW Priority DHW Valve Advanced Do not apply power 13 14 15 16 17 18 Uno Com Boil Out Com Indr Sw Signal wiring must be rated at least 300V. H1154D S1 = Boiler Supply Sensor 082 S2 = Outdoor Sensor 070 S3 = Hidden Indoor Sensor 084 P1 = System pump P2 = DHW Pump B1 = Boiler 1 D1 = Boiler demand (thermostat or end switch) A1 = DHW Aquastat To increase or decrease the building temperature: S1 D1 A1 P1 P2 S2 C R S3 120 V (ac) L B1 N tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright © 2011 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 2 of 2 All specifications are subject to change without notice. Printed in Canada. C 260 - 01/11.