Preview only show first 10 pages with watermark. For full document please download

Submittal Data Sheet

   EMBED


Share

Transcript

Submittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Code Factory model Indoor code Indoor unit factory model Outdoor code Outdoor unit factory model Model Indoor Outdoor MAC Indoor model MAC Outdoor model Approval: Date: Construction: Unit #: Drawing #: 22022010008735 US1-KFR53GW/BP2N1Y-MAC(P0)-W 22022011010561 US1-KFR53G/BP2N1Y-MAC(P0)-W 22022016010303 US1-KFR53W/BP3N1-B01(P0)-W MSMAC-18HRDN1-MP0W MSMAC-18HRDN1-MP0W MOB01-18HFN1-MP0W MES-18WBL2 MCS-181BL2 PERFORMANCE DATA Power supply Ph-V-Hz 208/230V~60Hz ,1Ph Cooling Capacity Btu/h 18000 Input W 1714 Rated current A 7.46 EER Btu/w 10.5 SEER Btu/w 17 Heating Capacity Btu/h 18000 Input W 1714 Rated current A 7.46 COP W/W 3.08 HSPF4 10.0 HSPF5 8.5 / Low temperature heating capacity(2℃) Btu/h / Low temperature heating capacity(-7℃) Btu/h MINIMUM CIRCUIT AMPACITY A 15 MAX.FUSE A 20 Moisture Removal L/h / Compressor Electrical Model ASM135D23UFZ Type ROTARY Brand GMCC Capacity Btu/h 13836 Input W 1035 Rated current(RLA) A ---Locked rotor Amp(LRA) A ---Thermal protector ---Thermal protector position ---ESTER OIL VG74/450 Refrigerant oil/oil charge ml 16AWG*4 Stranded, unshielded Connection wiring Plug type / Thermostat type Remote Control SYSTEM DATA Design pressure MPa 550/340 PSIG Refrigerant type oz R410A/45.9 Refrigerant precharge ft 25 Additional charge per ft. oz 0.161 Liquid side/ Gas side mm(in) Φ6.35/Φ12.7(1/4"/1/2") Max. refrigerant pipe length ft 98 Max. difference in level ft. 66 Application area sq.ft 258-379 INDOOR UNIT DATA Indoor fan motor Model Brand Input RLA LRA Winding Resistance Capacitor Speed(Hi/Mi/Lo) Air flow & Noise level Indoor air flow (Hi/Lo) Indoor noise level (Hi/Lo) Indoor unit Dimension(W*D*H) Packing (W*D*H) Net/Gross weight OUTDOOR UNIT DATA Outdoor fan motor Model Brand Input RLA LRA Winding Resistance Capacitor Speed Air flow & Noise level Outdoor air flow Outdoor noise level Outdoor unit Dimension(W*D*H) Packing (W*D*H) Net/Gross weight Operation temperature Indoor(cooling/ heating) Outdoor(cooling/heating) A A Ω uF r/min YKFG-28-4-6-5 Welling 58.5 0.4 0.356 183.6/206 1.5 1200/800 CFM dB(A) 416/196 43.5/29 inch inch lbs. 37.72x8.78x11.89 40.75x12.01x14.96 23.5/31.2 A A Ω uF r/min ZKFN-40-8-1L Welling 63 0.5 ---------880 / 690 CFM dB(A) 1470 57 inch inch lbs. 31.50x13.11x21.81 36.22x15.35x24.21 85.6/91.5 Deg. F Deg. F 62~90/32~86 5~122/5~86 INDOOR UNIT Model MSMAC-18HRDN1-MP0W W (inch) 37.72 D (inch) 8.78 H (inch) 11.89 OUTDOOR UNIT A B D Model MOB01-18HFN1-MP0W W (inch) 31.5 D (inch) 13.11 H (inch) 21.81 W1 (inch) 34.25 A (inch) 20.24 B (inch) 13.39