Preview only show first 10 pages with watermark. For full document please download

Submittal Data Sheet

   EMBED


Share

Transcript

SUBMITTAL DATA SHEET LX DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS MODELS: DCMF/DHMF - 16 SEER – 3/4 to 2 TONS – 1 PHASE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. PRODUCT DATA FIELD INSTALLED ACCESSORIES Cooling Performance Refer to Tecnical Guide and Price Pages for complete list of ductless accessories. Cooling ________ BTU/h Min/Max Cooling_________BTU/h Outdoor Design Temp_________°F SEER_________ EER________________ Low Ambient Temp.________________°F Heating Performance Heating ________ 47° BTU/h Heating _________17° BTU/h Outdoor Design Temp_________ °F HSPF___________ Low Ambient Temp.___________°F Outdoor Unit Compressor-DC Inverter Driven Noise Level ______________________dB Weight __________________________ Refrigerant Piping: Max Ht. Difference ________________ Max Total or Combined Length __________ Discharge Vapor Line (O.D.) ____________ Suction (O.D.) ________________________ FEATURES • • • • • • • • • • Six year compressor warranty. Two year parts warranty. R-410A with PVE oil. Auto mode Automatic lover operation. Catechin Filter (accessory). Sleep mode Cold air prevention (hot heat pump) Dry mode Low ambient operation CLEARANCES Outdoor Unit Required Clearance Clearance above unit 2 feet Clearance between air inlet and structure 12 inches Clearance between sides of unit and structure 12 inches Clearance between front of unit and structure 7 feet Electrical Data Power Supply________/__/__ Breaker Size ______________________ Recommended Fuse Size ___________ Min. Ampacity ____________________ Running Current __________________ Fan Motor (F.L.A) ____________ Total Unit Ampacity ____________AMPS Minimum Wire Size_____________AWG Indoor Unit Required Clearance Clearance between unit and ceiling 6 inches Clearance between unit and floor 6 feet Clearance to the right and left of the unit 6 inches Indoor Unit Remote Control - Wireless Noise Level ______________________dB Weight _________________________ Supply Air Blower Performance Total Supply Air (H/M/L/Q) ________________CFM Electrical Data Power Supply ________/__/__ Minimum Circuit Ampacity ____________AMPS Minimum Wire Size_____________AWG Fan Motor (F.L.A) ________________ Johnson Controls Unitary Products 923179-USD-B-0114 UNIT DIMENSIONS A 09K 12K B 5.0 21.6 3.7 C 18K 5.5 21.3 7.2 24K 5.1 7.6 27.0 Indoor Unit Dimensions Model Size Unit Gross Weight A B C 30.3 (770) 7.9 (201) 11.1 (282) 18K 34.1 (866) 8.5 (216) 24K 39.7 (1008) 8.7 (221) 09K 12K E Air Conditioner Heat Pump 25 lbs (11.5 kg) 25 lbs (11.5 kg) 27 lbs (12 kg) 27 lbs (12 kg) 12.0 (305) 35 lbs (16 kg) 35 lbs (16 kg) 12.4 (315) 44 lbs (20 kg) 44 lbs (20 kg) F C D G B A Outdoor Unit Dimensions Model Size 09K 12K 18K 24K A 28.0 (711) 37.9 (963) B 12.5 (318) 15.6 (396) C 21.7 (551) 27.6 (701) D 11.8 (300) 14.4 (366) E 10.8(274) 13.4 (340) F 25.9 (658) 35.0 (889) Subject to change without notice. Published in U.S.A. Copyright © 2014 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 7306 G 18.5 (470) 22.0 (559) Unit Gross Weight Air Conditioner Heat Pump 73 lbs (33 kg) 73 lbs (33 kg) 77 lbs (35 kg) 77 lbs (35 kg) 115 lbs (52 kg) 117 lbs (53 kg) 123 lbs (56 kg) 126 lbs (57 kg) 923179-USD-B-0114 Supersedes: 923179-USD-A-1112