Preview only show first 10 pages with watermark. For full document please download

Submittal Drawing P1xu 60-120 Input

   EMBED


Share

Transcript

JOB NAME PURCHASER ENGINEER SUBMITTED TO SUBMITTED BY LOCATION ORDER NO. FOR: Reference UNIT DESIGNATION: Schedule No. Approval DATE Construction MODEL NO. DIMENSIONS - INCHES PRODUCT DATA HEATING PERFORMANCE B 2 0 3 /4 INPUT CAPACITY . . . . . . . . . . . . . . . . MBH OUTPUT CAPACITY . . . . . . . . . . . . . . MBH AIR TEMP. RISE. . . . . . . . . . . . . . . . . . . . . °F G A S 1 -1 /4 ( A ll g c o n n SUPPLY AIR BLOWER PERFORMANCE 4 -1 /8 O U T L E T " X 2 -1 /2 " 7 -5 /8 a s p ip e e c tio n s 1 /2 " N P T ) 3 -1 /4 7 /8 " H O L E P O W E R W IR IN G 4 5 TOTAL SUPPLY AIR . . . . . . . . . . . . CFM TOTAL EXTERNAL STATIC PRESSURE . . . . . . . . . . . . . . . . . IWG BLOWER SPEED (circle) . . . . . . . HI MED LOW MOTOR RATING . . . . . . . . . . . . . . . . HP 7 -5 /8 1 -1 /4 1 -3 /4 1 -3 /4 T 'S T A T W I R I N G 7 /8 " K .O . 1 4 -1 /2 O P T IO N A L S ID E R E T U R N C U T -O U T (E IT H E R S ID E ) 2 2 -3 /4 6 -7 /8 9 -7 /8 ELECTRICAL DATA POWER SUPPLY . . . . . . . . . . . . . . TOTAL UNIT AMPS . . . . . . . . . . . . . . MINIMUM WIRE SIZE . . . . . . . . . . . . MAXIMUM OVERCURRENT DEVICE ❒ FUSES ❒ CIRCUIT BREAKER . . . / / AMPS AWG 3 /4 2 8 -1 /2 A F R O N T C O N D E N S A T E D R A IN L E F T S ID E A C B LBS. 2 8 -1 /2 CLEARANCES (Inches) Top Front Vent Pipe Rear L & R Sides Bottom R IG H T S ID E AMPS UNIT WEIGHT TOTAL UNIT WEIGHT . . . . . . . . . . 1 .................. 1 .................. 3 .................. 0 .................. 0 .................. 0 .................May be applied directly on a combustible floor NOTE: Refer to Form 650.78-TG1Y for detailed specifications. 2 0 D In ta k e C o n n e c tio n 2 3 F R O N T T O P IM A G E E V e n t C o n n e c tio n ( v e n t s iz e ) B O T T O M IM A G E (F R O N T ) 3 /4 " F L A N G E Model A B C D E P1XUB12N05501 P1XUB12N07501 P1XUC16N07501 P1XUC14N09501 P1XUC20N09501 P1XUD20N11201 17-1/2 17-1/2 21 21 21 24-1/2 16-1/4 16-1/4 19-3/4 19-3/4 19-3/4 23-1/4 13-1/8 13-1/8 16-5/8 16-5/8 16-5/8 20-1/8 2 2 2 2 2 3 2 2 2 2 2 2 (3) TWO STAGE DELUXE HIGH EFFICIENCY GAS-FIRED FURNACES TUBULAR HEAT EXCHANGER SERIES MODELS: P1XU (W IT H K .O . R E M O V E D ) FORM 650.78-SD1Y (998) Supersedes: Nothing ® FEATURES • Two stage heating operation includes: - Two stage gas valve - Two stage inducer operation - Two speed blower operation This provides both increased comfort level and very quiet unit operation • Delay timer allows two stage operationwith single stage thermostat • Compact, easy to install, ideal height 45" cabinet • Full height blower compartment allows side return application without the use of a return air box • Blower-off delay for cooling SEER improvement • Easy to connect power/control wiring • Built-in, high level self diagnostics with fault code display • Low unit amp requirement for easy replacement application • Integrated control module for reliable, economical operation • Reliable hot surface ignitor • May be installed as either two-pipe (sealed combustion) or single pipe vent (using indoor combustion air) • Top intake & vent connection allows installation in narrow locations • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability • Induced combustion system with inshot main burners for quiet, efficient operation • No special vent termination kit required • 100% shut off main gas valve for extra safety • PSC - multiple speed, direct drive motor with large, quiet blower • 24V, 40 VA control transformer and blower relay supplied for add-on cooling • Hi-tech tubular aluminized steel primary heat exchanger • Secondary (condensing) heat exchanger of 29-4C high-grade stainless steel • Timed on, adjustable off blower capability for maximum comfort • Blower door safety switch • Solid bottom with removable panel allows easy application • Easy access from front of unit for cleaning, maintenance or service • Protection from intake, exhaust or condensate blockage • High velocity filter provided for field installation FIELD INSTALLED ACCESSORIES: PROPANE CONVERSION KIT 1NP0347 - All units COMBUSTIBLE FLOOR BASE 1BR0314 - For "A" (14-1/2") cabinet 1BR0317 - For "B" (17-1/2") cabinets 1BR0321 - For "C" (21") cabinets 1BR0324 - For "D" (24-1/2") cabinets CONCENTRIC VENT TERMINATION 1CT0302 (2") 1CT0303 (3") CONDENSATE NEUTRALIZER KIT 1NK0301 HIGH ALTITUDE PRESSURE SWITCHES INTAKE/VENT SIZING - 1 OR 2 PIPE SYSTEM Model P1XUB12N05501 P1XUB12N07501 P1XUC16N07501 P1XUC14N09501 P1XUC20N09501 P1XUB12N05501 P1XUB12N07501 P1XUC16N07501 P1XUC14N09501 P1XUC20N09501 P1XUD20N11201 Pipe Size Max. Elbows vs. One Way Vent Length (Ft.) 5-40 45 50 75 2" 6 5 4 N/A 3" 8 7 6 5 3" Only 6 5 4 N/A NOTES: Subject to change without notice. FORM 650.78-SD1Y (998)