Preview only show first 10 pages with watermark. For full document please download

Submittal Drawing Pv9dh 060-120

   EMBED


Share

Transcript

SUBMITTAL DATA SHEET R CONDENSING HIGH EFFICIENCY DOWNFLOW/HORIZONTAL TWO STAGE VARIABLE SPEED GAS FURNACES MODELS: PV9 Heating JOB NAME: LOCATION: PURCHASER: ORDER NO: Air Conditioning ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. PRODUCT DATA CONSTRUCTION: MODEL NO. DIMENSIONS - INCHES Heating Performance 22-3/4 Input Capacity ________________ MBH Output Capacity _______________ MBH Air Temp. Rise__________________ °F Supply Air Blower Performance Total Supply Air_________________CFM Total External Static Pressure ____________________ IWG Blower Speed (circle) ______HI MH ML L Motor Rating ____________________HP Electrical Data A 7/8 T-STAT WIRING 7/8” K.O. 7/8 HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 40 HORIZONTAL CONDENSATE DRAIN OPENING 2” JUNCTION BOX HOLE 7/8” 22-3/4 GAS PIPE ENTRY 1-1/2” DOWNFLOW Top Front Vent Pipe Rear L & R Sides Bottom 1 3 0 0 0 May be applied directly on a combustible floor HORIZONTAL Top Front Vent Pipe Rear L & R Sides Bottom JUNCTION BOX HOLE 7/8” 22-3/4 21-5/8 CONDENSATE DRAIN HOLE 7/8” 21-1/4 18-1/2 18-1/2 11-3/4 7-1/2 SIDE PIPING HOLE 3-3/8” GAS PIPE ENTRY 1-1/2” 9-1/8 8-1/2 CONDENSATE DRAIN HOLE 7/8” 2-1/4 22-1/4 25-3/8 26-1/2 27-1/8 30-1/8 FRONT 23-11/16 23-5/8 1-1/4 19-1/4 LEFT SIDE RIGHT SIDE 5/8 1-1/4 E 5/8 D B C 20 2-1/4 23-1/4 BOTTOM IMAGE SUPPLY END Unit Weight CLEARANCES HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 29 29 Power Supply ________/__/__ Total Unit Ampacity ________AMPS Minimum Wire Size _________AWG Maximum Overcurrent Device Fuses Circuit Breaker____AMPS Total Unit Weight ________LBS T-STAT WIRING 7/8” K.O. HORIZONTAL CONDENSATE DRAIN OPENING 1-3/4” 13-7/8 TOP IMAGE RETURN END CABINET DIMENSION Models CFM CABINET SIZE A (in.) B (in.) C (in.) D (in.) E (in.) PV9B12N060DH11 1200 B 17-1/2 16-1/4 15 1-3/4 2-3/8 PV9B12N080DH11 1200 B 17-1/2 16-1/4 15 1-3/4 2-3/8 PV9C16N080DH11 1600 C 21 19-3/4 18-1/2 2-1/8 2-3/4 PV9C20N100DH11 2000 C 21 19-3/4 18-1/2 2-1/8 2-3/4 PV9D20N120DH11 2000 D 24-1/2 23-1/4 22 2-1/2 3 EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System 0 3 0 0 1 May be applied directly on a combustible floor Unitary Products Group 036-22940-001 Rev. A (0205) FEATURES • • • • • • • • • • • • Compact, easy to install, ideal height 40" cabinet. May be installed as either two-pipe (sealed combustion) or single-pipe vent (using indoor combustion air) Blower-off delay for cooling SEER improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. Insulated blower compartment for quiet operation. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. Induced combustion system with inshot main burners for quiet, efficient operation. No special vent termination kit required. 100% shut off main gas valve for extra safety. • • • • • • • • • • 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary (condensing) heat exchanger of 29-4C highgrade stainless steel. Timed on, adjustable off blower capability for maximum comfort. Internal vent coupling for maximum serviceability. High velocity filters and filter racks provided for field installation. Independent door removal for greater durability and ease of access. 3-way transition facilitates fresh air piping. Two stage heating operation includes: - Two stage gas valve - Two stage inducer operation ClimaTraK comfort system allows dealer to customize comfort settings based on regional location. FIELD INSTALLED ACCESSORIES Propane Conversion Kit Coil Transition Kit 1NP0580 1TK0917 - For 17-1/2” cabinets 1TK0921 - For 21” cabinets 1TK0924 - For 24-1/2” cabinets Concentric Vent Termination 1CT0302 - (2”) 1CT0303 - (3”) Required in downflow applications when using G*FD series coils. Condensate Neutralizer Kit Horizontal Sidewall Vent Termination 1NK0301 1HT0901 High Altitude Pressure Switches Combustible Floor Base 1PS0507 - 60 MBH Unit 1PS0508 - 80/1200 MBH Unit 1PS0509 - 80/1600 MBH Unit 1PS0510 - 100 MBH Unit 1PS0511 - 120MBH Unit 1CB0317 - For 17-1/2” cabinets 1CB0321 - For 21” cabinets 1CB0324 - For 24-1/2” cabinets INTAKE/VENT SIZING - TWO PIPE SYSTEM MAXIMUM ELBOWS AND VENT LENGTHS Models Input BTUH Pipe Size Inches 60,000 60,000 60,000 80,000/1200 80,000/1200 80,000/1600 80,000/1600 100,000/2000 100,000/2000 120,000 1-1/2 2 3 2 3 2 3 2 3 3 Maximum Number of Elbows* 1 15 60 85 60 85 55 80 25 80 55 2 10 55 80 55 80 50 75 20 75 50 3 N/A 50 75 50 75 45 70 15 70 45 4 N/A 45 70 45 70 40 65 10 65 40 5 N/A 40 65 40 65 35 60 N/A 60 35 6 N/A 35 60 35 60 30 55 N/A 55 25 7 N/A 25 50 25 50 20 45 N/A 45 15 8 N/A 15 40 15 40 10 35 N/A 35 N/A Minimum Length 5 5 20 5 20 5 20 5 5 5 Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table above. NOTES: ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2005. All rights reserved. Unitary Products Group 036-22940-001 Rev. A (0205) Supersedes: Nothing 5005 York Drive Norman OK 73069