Preview only show first 10 pages with watermark. For full document please download

Submittal Drawings B3ch 36-60

   EMBED


Share

Transcript

JOB NAME _______________________________________ LOCATION __________________________ PURCHASER _____________________________________________ ORDER NO. _________________ ENGINEER ____________________________________________________________________________ SUBMITTED TO: _________________ For: ____ Ref: _____ Approval: ______ Construction: ______ SUBMITTED BY: __________________________________ DATE: ______________________________ UNIT DESIGNATION: Schedule No. _________________ MODEL NO. ___________________ PRODUCT DATA DIMENSIONS - INCHES COOLING PERFORMANCE TOTAL CAPACITY SENSIBLE CAPACITY OUTDOOR DESIGN TEMP TOTAL SUPPLY AIR TEMP. OF AIR ENTERING INDOOR COIL POWER INPUT REQUIREMENT 48-5/8" (15 TON) 52-5/8" (20 TON) MBH MBH °F DB/WB CFM 21" °F DB/WB KW 125-1/4" (15 TON) 136-1/4" (20 TON) 5" 9-3/4" (LESS BLOWER MOTOR) FRONT VIEW 5-7/8" HEATING PERFORMANCE 35" CAPACITY @ 47 °F @ 17 °F COEFFICIENT OF PERFORMANCE @ 47 °F @ 17 °F MBH MBH 24-1/4 (15 TON) 35-1/4 (20 TON) 3-3/4" 33" COP COP (RESISTANCE HEAT - SEE REVERSE SIDE) 2-3/4" 21-1/2" UNIT BASE WITH RAILS SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR TOTAL RESISTANCE EXTERNAL TO UNIT BLOWER SPEED MOTOR RATING POWER INPUT REQUIREMENT POWER OUTPUT REQUIREMENT CFM (B) SHOWN SEPARATELY TO ILLUSTRATE BOTTOM DUCT OPENINGSAND POWER CONNECTION LOCATIONS. (A) NOTE: For curb mounted units, refer to the duct hanger dimensions of the curb for the proper size of the supply and return air duct connections. 8-1/8" 12-1/2" 9-3/4" 9-1/4" IWG RPM HP KW BHP ELECTRICAL DATA POWER SUPPLY TOTAL UNIT AMPACITY MINIMUM WIRE SIZE MAXIMUM OVERCURRENT DEVICE __ FUSES __ HACR BREAKER AMPS AWG RETURN AIR AMPS SUPPLY AIR CONDENSER AIR TOTAL UNIT WEIGHT (OPERATING) OUTDOOR AIR INCLUDING FACTORY INSTALLED OPTIONS (ECONOMIZER) LBS SUNLINE 2000TM SINGLE PACKAGE, HEAT PUMPS 15 & 20 TONS (8.5 - 8.8 SEER) MODELS B_CH 180 & 240 FORM: 511.06-SD3Y (395) Supersedes: 511.06-SD3Y (493) ® FEATURES • • • • • • • • • • • • • • • Powder paint finish that meets ASTM-B-117 750 hr. Salt spray standards Two-stage cooling provided by dual independent refrigeration circuits with expansion valves, filter-driers, high and lowpressure/loss of charge switches and freezestats Hermetically sealed compressors with crankcase heaters Permanently lubricated motors Bottom or side air discharge configuration capability - field convertible Belt drive blower motor - standard Manufactured underthe quality standards of ISO 9002 24 Volt control circuit with compressor lock-out 0-25% fixed air damper with hood • Copper tube/aluminum fin coils Easy access to all components Rigging holes in base rails for lifting Single point power connection Complete factory package - tested, charged, wired Agency approvals: - ETL & CGA on all units Factory limited parts warranty - One year on the complete unit - Four additional years on the compressors - Four additional years on the electirc heating elements CLEARANCES (Inches) FIELD INSTALLED ACCESSORIES Front Roof Curb ............................................................................................ Compressor Cycle Timer .................................................................... Electronic Thermostat ......................................................................... Barometric Relief ................................................................................. Side Duct Flange ................................................................................. High Speed Drive ................................................................................ Economizer (with Barometric Relief) ................................................... Single Input Enthalpy Control ........................................................... Dual Input Enthalpy Control ............................................................. Motorized Outdoor Air Damper ........................................................... 36" 24" (Less Economizer) 49" (With Economizer) Back Left Side 24" (Less Economizer) (Filter Access) 36"1 (With Economizer) Right Side 36" (Outdoor Coil) Below Unit2 0" Above Unit3 72" w/36" Max. Horizontal Overhang (For Outdoor Air Discharge) 1 FACTORY INSTALLED OPTIONS If a factory installed economizer is furnished, the assembled hood kit must be removed prior to installation. The hood is 54” long. 2 Units (applicable in USA only) may be installed on combustible floors made from wood or class A, B or C roof covering material. 3 Units must be installed outdoors. Overhanging structures or sgrubs shoud not obstruct outdoor air discharge outlet. NOTE: Units and ductwork are approved for zero clearance to combustible materials when equiped wth electric heaters. OUTDOOR AIR Economizer (with Barometric Relief) Single Input Enthalpy Control ........................................................... ✔ Dual Input Enthalpy Control ............................................................. ✔ Single Input Enthalpy Control w/Power Exhaust ............................ ✔ Dual Input Enthalpy Control w/Power Exhaust ............................... ✔ Motorized Outdoor Air Damper ........................................................... ✔ Phenolic Coated Condensor Coil ........................................................ ✔ Resistance Heat* ................................................................................. ✔ ______ Capacity (At __________ Volts) _______ Mbh Power Input Requirement________ Kw UTILITIES ENTRY DATA OPENING SIZE HOLE (DIA.) A * Units with electric heat have a single power supply. Refer to Product Data on front side for electrical data. B 1 1/8" KO 3/4" NPS (Fem) 3 5/8" KO 3" NPS (Fem) USED FOR Front Bottom Front Power Wiring Bottom Control Wiring (DETAIL “Y” UNIT WITH RAIN HOODS SUPPLY AIR COMPARTMENT POWER EXHAUST RAIN HOOD (on Return Air Compartment) ECONOMIZER MOTORIZED DAMPER RAIN HOOD (on Outdoor Air Compartment) ECONOMIZER / MOTORIZED DAMPER AND POWER EXHAUST RAIN HOODS FIXED OUTDOOR AIR INTAKE HOOD (located on Return Air Compartment) 34-1/4" 1" CONDENSTATE DRAIN (Must be trapped) 16-1/8" 5" 36" 66-1/2" REAR VIEW 2" 36-1/4" 92" LH VIEW NOTES: _______________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ Subject to change without notice. FORM: 511.06-SD3Y (395)