Transcript
DX11S Commercial Split System Air Conditioners 7½ & 10 Tons
Submittal Data Form Job Name Location Purchaser Order No. Engineer Unit No. Model No. Unit Designation
Performance Data Certified By:
Standard Features • • • • •
R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter dryer Copper tube/enhanced aluminum fin coil Service valves with sweat connections and easy-access gauge ports • Contactor with lug connection • Ground lug connection • ARI Certified; ETL Listed
Cabinet Features • • • •
Innovative sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Attractive Nickel Gray powder-paint finish with 500-hour salt-spray approval • Top and side maintenance access • Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
* Complete warranty details available from your local dealer or at www.daikincomfort.com.
SS-DX11SC
www.daikincomfort.com
7/13
Job Name
Location
Performance Data for Split System Indoor Unit: __________
Outdoor Unit: __________
Heating Performance
Cooling Performance Total Capacity Sensible Capacity Outdoor Design TMP Air Temp entering Evaporator Coil Power Input Required (less blower motor)
MBH MBH ºF DB / WB ºF kW
Total Heating Capacity
kW BTU/h
Supply Air Blower Performance Total Supply Air Ext. Static Pressure Blower Speed Power Output Required Motor Ratings Power Input Required
CFM IWG RPM BHP HP kW
Electrical Data Power Supply Total Unit Amps Max Overcurrent Device: Fuse Breaker
Amps
Notes
2
www.daikincomfort.com
SS-DX11SC
SS-DX11SC
www.daikincomfort.com
A
B
C
D
E
6s
= 6SIGMA
8
CC
7
7
= CRITICAL CHARACTERISTIC
35.6 (904.2 mm)
SPECIAL CHARACTERISTICS:
8
SC
6
26.0 (660.4 mm)
5
Top View
4
26.5 (673.1 mm)
3 ECN
4
3
2 DESCRIPTION
35½ 35½
DX11S1203A DX11S1204A
35½
35½
35½
35½
D"
DATE
41½
41½
41½
41½
H"
XXX XX-XX-XX
2
DRAWING TO BE INTERPRETED IN ACCORDANCE WITH ASME Y14.100 DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED TOLERANCES: DWN BY: GMEHOU1SJK ANGLES ± 1.5° CHK BY: PAMELA CYRILIEN .X : ± .1 .XX : ± .03 .XXX : ± .015 HOLE Ø : ± .005 TUBE CUT LG: ± .063
ENG: DATE:
1
GSH13
A
REV
SHT 1 OF 1
DO NOT SCALE DRAWING
GSH13 DX11S
THE GOODMAN MANUFACTURING COMPANY, L.P.
Rear View
35½
DX11S0904A
W"
-
CHK DR
1
Dimensions
INITIAL RELEASE
35½
XXXXX
DX11S0903A
CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
5
A
REV ZONE
Model
XXXXXXX
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL AND FINISH.
Side View
= SIGNIFICANT CHARACTERISTIC
26.5 (673.1 mm)
26.0 (660.4 mm)
6
A
B
C
D
E
Job Name Location
Certified Dimensions
3
Job Name
Location
Accessories List Model
Description
ABK-20
Anchor Bracket Kit ◊
CHTD18-60
Digital room thermostat with 1-stage cool/1-stage heat
CHT18-60
Standard room thermostat with 1-stage cool/1-stage heat
FSK01A
Freeze Protection Kit ¹
LA-01
Low Ambient Kit
LSK01A
Liquid Line Solenoid Kit
√
Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ◊
Our continuing commitment to quality products may mean a change in specifications without notice. © 2013 • • Houston, Texas • Printed in the USA.
4
www.daikincomfort.com
SS-DX11SC