Preview only show first 10 pages with watermark. For full document please download

Submittal Form Pdf

   EMBED


Share

Transcript

DX11S Commercial Split System Air Conditioners 7½ & 10 Tons Submittal Data Form Job Name Location Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard Features • • • • • R-410A chlorine-free refrigerant Energy-efficient compressor Factory-installed filter dryer Copper tube/enhanced aluminum fin coil Service valves with sweat connections and easy-access gauge ports • Contactor with lug connection • Ground lug connection • ARI Certified; ETL Listed Cabinet Features • • • • Innovative sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Attractive Nickel Gray powder-paint finish with 500-hour salt-spray approval • Top and side maintenance access • Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.daikincomfort.com. SS-DX11SC www.daikincomfort.com 7/13 Job Name Location Performance Data for Split System Indoor Unit: __________ Outdoor Unit: __________ Heating Performance Cooling Performance Total Capacity Sensible Capacity Outdoor Design TMP Air Temp entering Evaporator Coil Power Input Required (less blower motor) MBH MBH ºF DB / WB ºF kW Total Heating Capacity kW BTU/h Supply Air Blower Performance Total Supply Air Ext. Static Pressure Blower Speed Power Output Required Motor Ratings Power Input Required CFM IWG RPM BHP HP kW Electrical Data Power Supply Total Unit Amps Max Overcurrent Device: Fuse Breaker Amps Notes 2 www.daikincomfort.com SS-DX11SC SS-DX11SC www.daikincomfort.com A B C D E 6s = 6SIGMA 8 CC 7 7 = CRITICAL CHARACTERISTIC 35.6 (904.2 mm) SPECIAL CHARACTERISTICS: 8 SC 6 26.0 (660.4 mm) 5 Top View 4 26.5 (673.1 mm) 3 ECN 4 3 2 DESCRIPTION 35½ 35½ DX11S1203A DX11S1204A 35½ 35½ 35½ 35½ D" DATE 41½ 41½ 41½ 41½ H" XXX XX-XX-XX 2 DRAWING TO BE INTERPRETED IN ACCORDANCE WITH ASME Y14.100 DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED TOLERANCES: DWN BY: GMEHOU1SJK ANGLES ± 1.5° CHK BY: PAMELA CYRILIEN .X : ± .1 .XX : ± .03 .XXX : ± .015 HOLE Ø : ± .005 TUBE CUT LG: ± .063 ENG: DATE: 1 GSH13 A REV SHT 1 OF 1 DO NOT SCALE DRAWING GSH13 DX11S THE GOODMAN MANUFACTURING COMPANY, L.P. Rear View 35½ DX11S0904A W" - CHK DR 1 Dimensions INITIAL RELEASE 35½ XXXXX DX11S0903A CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT. 5 A REV ZONE Model XXXXXXX COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL AND FINISH. Side View = SIGNIFICANT CHARACTERISTIC 26.5 (673.1 mm) 26.0 (660.4 mm) 6 A B C D E Job Name Location Certified Dimensions 3 Job Name Location Accessories List Model Description ABK-20 Anchor Bracket Kit ◊ CHTD18-60 Digital room thermostat with 1-stage cool/1-stage heat CHT18-60 Standard room thermostat with 1-stage cool/1-stage heat FSK01A Freeze Protection Kit ¹ LA-01 Low Ambient Kit LSK01A Liquid Line Solenoid Kit √ Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ◊ Our continuing commitment to quality products may mean a change in specifications without notice. © 2013 • • Houston, Texas • Printed in the USA. 4 www.daikincomfort.com SS-DX11SC