Submittal Job Name Location Purchaser

   EMBED


Share

Transcript

SUBMITTAL QSHE-243 / QSHC-243 www.Quietside.com Wall mounted, single zone, split system Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Specifications Nominal Capacity* Performance* 24,000 24,000 13 / 11.3 7.7 4.4 Cooling (Btu/h) Heating (Btu/h) SEER / EER HSPF Condensate (pints/hour) Voltage (ø/V/Hz) Power 1 / 208-230 / 60 8.5 8 20 13.8 A Cooling Heating Max Breaker Amps Min. Circuit Ampacity Rated Current (amps) Dimensions Indoor Unit Outdoor Unit Indoor Unit Weight (lbs.) Outdoor Unit Condensate Connection Heat Exchanger Type Indoor & FPI Outdoor Unit Pipe Diameter 48 1/4 X 13 X 9 5/8 35 1/2 X 32 7/8 X 13 44 143 11/16" OD WXHXD (Inches) Aluminum Fin - Copper Tube 18 1/4" High/Medium/Low Sound Pressure Indoor Unit Level (dB) Outdoor Unit Operating Temperatures* Cooling Heating ⁰F ⁰F 50 / 47 / 44 59 65 ≤ T ≤ 115 14 ≤ T ≤ 70 *Cooling below 65⁰F is possible using a low ambient kit and crankcase heater Pipe Connections Refrigerant High side Low side Maximum Line Set Length Maximum Vertical Separation Indoor & Outdoor Type Control Method Factory Charge Charged for Additional Refrigerant Type Compressor RLA L.R.A. Evaporator Fan RLA Air Volume Accessories Amps CFM Cross Flow 0.4 610 / 665 / 725 W Amps PSC 60 0.9 Condensate pump Low Ambient Kit Wall Bracket Line Sets - 25' and 50' (Insulated and flared, interconnect cable included) Safety Certifications Warranty R410A Capillary Tube 78.4 oz 25 feet 0.3oz / ft over 25 feet Single Speed Rotary 10 46 Motor Condenser Fan Output RLA 3/8" 5/8" 50' 20' Amps Amps Type QSHE-243 QSHC-243 • Construction • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability • The indoor shall have a UL94 V0 chassis with galvanized steel mounting bracket Heat Exchanger • The heat exchanger shall be mechanically bonded fin to copper tube Controls • The unit shall be operated via communication with line voltage signal • SLS-2508 / SLS-5008 ETL & ETLc 5 Years compressor, 1 Year Parts, 90 Day limited labor Defrost is initiated by demand, not time • 14AWG X 6 interconnect wire between condenser and evaporator • ASP-MO-UNIV 110-250 ICM-326H CKN-250 (or larger model) Electro-static, washable, main filter as standard Evaporator ships with wireless controller as standard Refrigerant System • The refrigerant shall be R410A • The compressor shall be a hermetically sealed rotary type • Refrigerant flow shall be controlled by capilary tube at outdoor unit • The reversing valve shall be energized for heating mode Indoor Fan • Indoor fan is a single, crossflow type • Four speed settings and auto setting • An auto swing louver shall direct airflow *Nominal cooling capacities are based on: Indoor temperature: 80⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. *Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. Quietside maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. 888-699-6067 www.Quietside.com