Preview only show first 10 pages with watermark. For full document please download

Submittal - Titus Hvac

   EMBED


Share

Transcript

Submittal 350R 1.0 11-30-11 Louvered Return Grilles • Steel Models: 350RL • 35° Deflection 350RS • 35° Deflection • Long Blades • ¾” Blades Spacing • Short Blades • ¾” Blades Spacing Border Type 1 (Surface Mount) D plus 1 3/4" 1 1/4" 9/16" 0 1/4" 35 3/4" Screwdriver Slot Operator For Optional Damper 1 1/4" 2 5/8" Optional Model AG-15 Opposed Blade Damper D minus 1/4" Note: When Damper Is Full Open, Add 3/8" To Overall Depth. Nominal Duct Size D " Available Sizes (D” x D”) Border Type 1 is available in sizes 6” x 4” through 48” x 48” in 1” increments in one piece construction. Odd and fractional sizes are available at additional cost. Sizes larger than 48” x 48” are shipped in multiple sections with joining strips for field assembly. Note: Wall or duct opening should be duct size ± 1/8”. All dimensions are in inches. Fastenings Mounting Frames Type C • Concealed Screw Type A • External Screw Duct Size minus 3/4" 1 1/4" x 3/4" Angle Clip Attached To Grille (By Titus) PF • Steel Plaster Frame Duct plus 2 3/8" 1/4" 5/16" #8 Screw (By Others) 1 1/2" Duct plus 1/16" Surface Mounted Example IS • Insect Screen (1/16” square mesh – galvanized steel) EQT • Earthquake Tabs DS • Debris Screen (¼” square mesh – galvanized steel) Duct plus 1/16" Recessed Mounted Example Note: Wall opening should be listed duct size + 1/8” to listed duct size + 1/4”. if provided. Neck mounted opposed blade damper (galvanized steel) 1/4" 1 1/2" Duct Available with Border Type 1 only. Type C fastening available with damper. Duct plus 1 7/8" 1/4" 5/16" 1/4" Duct Size Check Duct plus 2 3/8" Duct plus 1 7/8" 1/4" 1 1/4" x 3/4" Angle Clip (By Others) Accessories (Optional) PFA • Aluminum Plaster Frame Standard Finish: #26 White Other Finish: __________________ Other: ____________________ General Description • Available with louvers vertical or horizontal. • #8 x 11/4” lg. Phillips flat head sheet metal screws painted white. • Optional opposed blade damper has screwdriver adjustment accessible through face of grille. • Material is Steel. • All dimensions are ± 1/16”. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies. 350R 2.0 11-30-11 Optional Border Types Available Border Type 2 (Snap-in) Panel Mounted Border Type 3 (Lay-in) Panel Mounted 13/16" Ceiling Module Size minus 1/4" Ceiling Module Size minus 1/16" Available in 24” x 24” modules with neck sizes up to 20” x 20”. Available in all standard module sizes with neck sizes up to module size minus 2”. Border Type NT (Narrow Tee) Border Type 4 (Spline) Panel Mounted 3/8" 3/8" Ceiling Module Size plus 3/4" Available in 24” x 24” modules with neck sizes up to 20” x 20”. Splines on 2 opposite sides only NT Border is available in module sizes 24" x 12" & 24" x 24" only. Border Type 2, 3, 4, NT • Accessories & Options Check if provided. AG-15 • Neck mounted opposed blade damper (galvanized steel) IS • Insect Screen (1/16” square mesh – galvanized steel) DS • Debris Screen (1/4” square mesh – galvanized steel) EQT • Earthquake tabs Other: _______________________ Standard Finish: #26 White Optional finish: _______________________ This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies.