Preview only show first 10 pages with watermark. For full document please download

Submmd0304bh2ul

   EMBED


Share

Transcript

S M M S i / S HR M i V RF I ndo or Uni t HFGTYUT MMD-AP0304BH2UL - Medium Static Ducted Model: MMD-AP0304BH2UL Submittal Data Unit – (s) #: SMMSi /SHRMi VRF Medium Static Features • • • • • • • • • Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R-410A Capacity R-410A Refrigerant Eleven sizes from 7,500 to 48,000 Btu/h Standard condensate pump with 10.7” lift capability Quiet operation, as low as 27.5 dB(A) Sound Pressure Rear return Configurable for bottom return. Optional wired or wireless controls Auto or manually set three fan speeds 1 inch track for field supplied filters One year parts limited warranty Fan System Type x Number . . . . . . . . . . . . . . . . . . . . . . . . . . Centrifugal x 1 Cooling (Btu/h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30,000 Air Flow Rate CFM (L-M-H) . . . . . . . . . . . . . . . . .424 - 694 - 788 Heating (Btu/h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34,000 Max Ext. Static Pressure In. WG . . . . . . . . . . . . . . . . . . . . .0.48 Electrical Motor Power Source . . . . . . . . . . . . . . . . . .208 / 230V, 1-Phase, 60 Hz Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC Inverter Driven Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.091 kW Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Full Load Amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 A Minimum Circuit Amps (MCA) . . . . . . . . . . . . . . . . . . . . . . . 1.8 A Maximum Over Current Protection (MOCP). . . . . . . . . . . . . .15 A Physical Characteristics External Finish . . . . . . . . . . . . . . . . . . Zinc Hot Dipped Steel Plate Dimensions Sound Pressure Levels Low-Med-High dB(A) . . . . . . . . . . . . . . . . . . . . . . . . .31 - 33 - 35 Refrigerant Piping Connections Liquid (High Pressure) . . . . . . . . . . . . . . . 3/8" / 9.52 mm (Flare) Gas (Low Pressure). . . . . . . . . . . . . . . . .5/8" / 15.87 mm (Flare) 1/5 W W xx 53 313/16 1/2 D Inches Unit. . . . . . . . . . . . . . . 12 .129/16 9/16 H H xx 53 39 3/8 D mm Unit . . . . . . . . . . . . . . . . . . . .320.0 H x 1351.3 W x 800.1 D Net Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119 lbs. / 53.9 kg Drainpipe Connection O.D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 -1/4" / 31.8 mm I.D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1" / 25.4 mm Accessories □ Wired Controller w Timer . . . . . . . . . . . . . . . .RBC-AMT32UL □ Remote Sensor . . . . . . . . . . . . . . . . . . . . . . . . . TCB-TC21LUL □ 7 Day Prog. Wired Controller . . . . . . . . . . .RBC-AMS51E-ES . . RBC-AMS41UL □ Fan Guard** . . . . . . . . . . . . . . . . . . . . . . . . . . TCB-IG211BUL □ Simple Controller . . . . . . . . . . . . . . . . . . . . . . . .RBC-AS21UL * With Stand Alone Receiver □ Wireless Remote Kit* . . . . . . . . . . . . . . . . . . . . TCB-AX21UL ** Required with Bottom Return Applications DIMENSIONAL DRAWING -- INDOOR UNIT Medium Static Ducted Model: MMD--AP0304BH2UL Drain pipe connecting port VP25(Polyvinyl chloride tube): External Dia., 1-1/4” (31.7) Internal Dia., 1” (25.4) Unit external dimension 31.5"(800) 2"(50) 19.6"(498) 1.6"(41) Unit external dimension B 2"(50) 1.7"(42) Supply air duct flange dimensions C 5.5"(140) Supply Air 1.2"(30) 6.3"(159.9) 5"(127) 15.1"(384) 9.5"(240) 0.3" 2.4"(59) 25.1"(638) 5.2"(131) 1” Air filter track Hanging bolt spacing A 2.2"(57) Hanging bolt spacing 27.6” (700) 1.6"(41) Air filter track Z 12.6"(320) 1"(25) Outside 8.6"(218.2) 5.8"(147.5) Return Air Refrigerant pipe connecting port G (Gas side) 1.7"(44) 1.9"(49) 1"(26) Hole for control wire and remote control wiring 7/8"(22.2) Hole for power supply cable Refrigerant pipe connecting port H (Liquid side) Bottom Return Accessory fan guard required Hanging bolt Air filter track Supply Air 12"(300) or less 6.3"(159) 9.6"(243.2) Outside 9.6"(243.2) 12.6"(320) Drain connection Drain connection is ABS. If drain piping is PVC, the correct glue must be used 1.2"(30) Return air flange 2.2"(57) 21.7"(550) or less 10.7"(271) or less (per local codes) 3.6"(91) Return Air Return air duct flange dimensions D Z view Space required for installation and servicing Clearance required for maintenance and service Supply Air Electrical control box Unit width B Ceiling opening size Ceiling opening size E * 17.7"X17.7" (450X450) 5.9"(150) or more 4"(100) Optional access area B* 4"(100) 5.9"(150) or more Supply Air Air filter (locally procured) access area A* 17.7"X17.7" (450X450) Ceiling Electrical control box 15.5"(400) (Min.) † 31.5"(800) Air filter (locally procured) Return air 1.2"(30) 5.9"(150) Ceiling Drain pan / Drain pump check cover Ceiling opening size * 38.6"(980) Space for removing or replacing the filter F Space for removing or replacing the filter F Electrical control box NOTES: • Access area A is required for maintaining and servicing the electrical box, filter, drain pump, drain pipe, and refrigerant pipe • The filter can be replaced through access area A or B ONLY. • When routing the refrigerant and drain pipe, do not block access to control box and filter. • Filters are field supplied per local code requirements. Un it :in (m m ) *Required if installation is not above a suspended ceiling. †In case of bottom return: 17.7” (450) min. Model A MMDAP0074BH2UL, AP0094BH2UL, 24.3" A0124BH2UL (616) 42" AP0154BH2UL, AP0184BH2UL (1066) AP0214BH2UL, AP0244BH2UL, 55.7" AP0304BH2UL, AP0364BH2UL, (1416) AP0424BH2UL, AP0484BH2UL Copyright 2014 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 B C 21.7" 13.9" (550) (351.6) 39.4" 31.6" (1000) (801.6) D E 18.6" 23.6" (471.6) (550) 36.3" 41.3" (801.6) (1050) F G H 23.6" 0.375" 0.25" (550) (9.5) (6.4) 23.6" 0.50" 0.25" (550) (12.7) (6.4) 53.2" 45.4" 50.1" 55.1" 40.5" 0.625" 0.375" (1350) (1151.6) (1271.6) (1400) (1030) (15.9) (9.5) Edition Date: 02/14 10/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 02 Catalog No:SUBMMD0304BH2UL---01 Replaces: NEW Replace: SUBMMD0304BH2UL-01