Preview only show first 10 pages with watermark. For full document please download

Sun™ Storagetek™ 6140 Array - Integrated Communications

   EMBED


Share

Transcript

SOLUTIONS SHEET Sun™ StorageTek™ 6140 Array RAID and segment size migration, and changing volume characteristics all can be done on the fly, optimizing protection and minimizing risk. Software for business continuity Sun™ StorageTek™ 6140 Array The Sun™ StorageTek™ 6140 array is ideal for primary storage within business-critical applications and data protection solutions. It is an affordable entry point into a family of products that grows with businesses in capacity, availability, performance, and connectivity, so users can manage data with confidence. Flexible configurations — start small, grow The array supports up to 112 disks, is upgradable, and is compatible across its product family. The StorageTek modular line shares a common building block for capacity increases, data-inplace migration, and mixing SATA and Fibre Channel drives within a storage module. Simplify management and configuration SMI-S-compliant Sun StorageTek Common Array Manager software is the array’s browserbased, application-oriented management console. Accessible from anywhere, it requires only a secure Internet connection. Sun StorageTek Data Replicator software enables synchronous and asynchronous replication to remote sites for extended data protection and continuous access. Sun StorageTekTMData Snapshot software conserves costly disk space with real-time protection of critical volumes. Sun StorageTekTM Volume Copy software quickly creates independent copies of production volumes. Added value and cost savings with Sun System Packs Sun System Performance Packs exceed the traditional warranty and include 24-hour technical support by phone, extended onsite coverage hours, SunVIPSM crossvendor/-platform interoperability problem management, and access to online learning resources. Sun System Performance Plus Packs add essential services to help deploy and maintain your modular storage. Systems and Network Integration Division Founded on 45 years of financial stability and back-to-back high tech know-how, Continental Resources (CRI) offers you the knowledge, support and fast delivery that keep your business operating at peak efficiency. Whether you’re an I.T. Professional in business, government or academia, you can rely on CRI for enterprise-class solutions ranging from virtualization to directory services; from business compliance to information lifecycle management; from security to IP telephony; from Unix, Solaris and Linux to Windows. CRI is a Sun Executive-Level Partner and Learn more about the Sun™ StorageTek™ 6140 Array by contacting your local CRI representative at 800.937.4688 (Option 1). one of the largest resellers in the U.S. Complete system availability Redundant design includes switched technology with point-to-point connections. Controller firmware upgrades, capacity and volumes additions, www.conres.com 800-937-4688 Sun™StorageTek™ 6140 Array Specifications Sun StorageTek 6140 array 6140 - 2 GB cache Controller card Dual Fibre Channel RAID controller cards 6140 - 4 GB cache Cache size (with ECC protection) 2 GB data cache 4 GB data cache Host ports Four (SFPs) Eight (SFPs) Host interfaces/link speeds Switched FC or FC-AL/4 Gbps, 2 Gbps, 4 Gbps Other interfaces (FC or SAS) Two 4 Gbps or 2 Gbps FC expansion ports Two six-pin Mini-DIN to nine-pin serial ports Four RJ45 10/100 Base-T network connectors RAID levels 0, 1, 3, 5, 1+0 and 6 (p+q) Cache battery backup Up to 72 hours Integrated data services premium features (optional) • Sun StorageTekTM Data Snapshot (optional) (support up to eight snaps per volume, 512 per array) • Sun StorageTekTM Data Volume Copy (optional) (supports up to eight active copies per volume, 1,024 per array) • Sun StorageTekTM Data Replicator (optional) (supports up to 64 replicated volumes) • Sun StorageTekTM Storage Domains (supports up to 128 storage domains) (6140 - 2 GB cache supports up to 32 only) Dynamic capacity expansion Five to 64 drives – 365 GB to 64 TB Expansion tray Up to 3 expansion trays Up to 6 expansion trays Drive depopulation Scales from 5 to 16 hard disk drives per tray Volume Up to 1,024 Up to 1,024 Global hot spares 30 30 Maximum array capacity 64 TB 112 TB Five to 112 drives – 365 GB to 112 TB Disk drives Form factor 3.5 in., low-profile Interface Dual-ported Fibre Channel Supported drives/system per tray capacity (raw, unformatted): Fibre Channel drives 73GB 15,000rpm 4Gbps 146 GB 15,000rpm 4Gbps 400 GB 10,000rpm 4Gbps SATA-II drives 500 GB 7,200rpm 3Gbps 1,000 GB 7,200rpm 3Gbps Systems and Network Integration Division Host connectivity Host/HBA/FC switches Multipath driver Warranty Duration: Phone Support: Onsite Service: Onsite Response Time: Height x width x depth Weight (maximum) 12.95cm (5.1 in.) x 44.70cm (17.6 in.) x 57.15cm (22.5 in.) 40 kg (88 lbs.) Power requirements AC power DC power 1,168 GB per tray (3 RU) 2,336 GB per tray (3 RU) 6,400 GB per tray (3 RU) 8,000 GB per tray (3 RU) 16,000 GB per tray (3 RU) • Sun StorageTekTM QFS Software • Sun StorageTekTM SAM-FS Software • SunTM Cluster Software • Sun StorageTekTM Enterprise Backup Software (EBS) • SolsticeTM DiskSuite 4.2.1 (in conjunction with the Solaris 8 Operating Environment) • SolarisTM Volume Manager (embedded in the Solaris 9 Operating Environment) • Symantec NetBackup (NBU) • Symantec Volume Manager with DMP (VxVM) • Symantec File System (VxFS) • Symantec Storage Foundation Operating temperature Relative humidity Altitude Shock Vibration Heat output 3.96 A max. operating @ 115 V AC (90 to 136 V AC range), 50/60 Hz 2.06 A max. operating @ 240 V AC (180 to 264 V AC range), 50/60 Hz 17 A max. operating (-36 to -72 V DC range) 15° C to 40° C (41° F to 104° F) 5–85% noncondensing 100 ft. (30.5m) below sea level to 9,840 ft. (3,000m) 10 G, 11 ms half-sine Random vibration to specified power spectral density 460 W (1,571 BTU/hr.) Regulations Safety and emissions Immunity Ruggedized IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15 (47CFR15B), CISPR 22 (EN55022—RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3 CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000 4-6, IEC 61000-4-11 NEBS Level 3 (GR-63-CORE; GR-1089-CORE), ETSi EN 300 386 BOSTON Sun StorageTek Common Array Manager — included CHICAGO Operating system support Three years 8 a.m. - 8 p.m., Mon. - Fri. Next business day, 8 a.m. - 5 p.m., Mon. - Fri. Next business day, local business hours Dimensions Management software support HTTPS://extranet.stortek.com/interop/interop Sun Traffic Manager for the Solaris OS Veritas DMP, as well as native driver for other operation systems Environmental Supported software SOLUTIONS SHEET DC • SolarisTM Operating System 8,9, 10, and x64 • Microsoft Windows 2000 Server and Advanced Server (SP4) • Microsoft Windows 2003 Server Standard, Enterprise, and Web editions • HP-UX 11.11 and 11.23 • IBM AIX 5.3, 5.4 • Red Hat Linux AS/ES/WS Enterprise edition 4.0/5.0 • SUSE Linux LES 9 and 10 • Netware 6 SP5, Netware 6.5 SP3 • VMware ESX 3.0 NEW JERSEY Corporate Headquarters 175 Middlesex Turnpike PO Box 9137 Bedford, MA 01730-9137 Sun, Sun Microsystems, the Sun logo, Solaris, Solstice, Spectrum, StorageTek, and SunVIP are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All information is subject to change without notice. © 2008 Continental Resources, Inc. Specifications subject to change without notice. Continental Resources not responsible for typographical errors. All product and manufacturer names are trademarks or registered trademarks of their respective companies. Printed in U.S.A. CRI 3019-0804-0 new york city philadelphia/de valley www.conres.com 800-937-4688 ideal for commercial applications and high-performance environments Sun™ StorageTek™ 6540 Array Boost protection with highavailability architecture High reliability is a prerequisite for high availability, and the Sun StorageTek 6540 array’s design permits non-disruptive capacity additions and the ability to change volume characteristics on the fly to optimize protection and minimize risk. The Sun™ StorageTek™ 6540 Array The Sun™ StorageTek™ 6540 array is designed to handle large data sets in applications such as OLTP, HPTC, and databases. It delivers marketleading performance for primary storage and is a cost-effective business continuity solution. Like all systems in the Sun StorageTek Modular disk family, the array is designed to deliver investment protection and exceptional data protection while applications evolve. Systems and Network Integration Division Founded on 45 years of financial stability Simplify management and configuration and back-to-back high tech know-how, The SMI-S-compliant Sun StorageTek Common Array Manager (CAM) software is the array’s browser-based, application- oriented management interface. The easyto-use GUI provides at-your-fingertips control through 15 predefined or custom profiles. CAM includes built-in performance tracking and automated diagnostics, so users may focus on precise, predictable, and repeatable results. the knowledge, support and fast delivery Expand capacity with online, datain-place functionality services; from business compliance to The Sun StorageTek 6540 array supports up to 224 disks and is upgradable and compatible with other members of the Modular portfolio. A storage module provides a building block for the entire portfolio and allows pay-as-you-grow capacity increases. Users can mix SATA and Fibre Channel drives to design a tiered storage environment with centralized management and integrated data services for business continuity. Continental Resources (CRI) offers you that keep your business operating at peak efficiency. Whether you’re an I.T. Professional in business, government or academia, you can rely on CRI for enterprise-class solutions ranging from virtualization to directory information lifecycle management; from security to IP telephony; from Unix, Solaris™ and Linux to Windows. CRI is a Sun Executive-Level Partner and one of the largest resellers in the U.S. Added value and cost savings with Sun System Packs Sun System packs exceed the traditional warranty and include 24-hour technical support by phone, extended on-site coverage hours, SunVIP™ cross-vendor/platform interoperability problem management, and access to online learning resources. www.conres.com 800-937-4688 StorageTek 6540 Array Specifications StorageTek 6540 array Storage Solutions Controller card Dual Fibre Channel RAID controller Cache size (with ECC protection) 4 GB, 8 GB, or 16 GB dedicated data cache Host interfaces/link speeds Eight 4 Gbps direct, arbitrated loop or switched attach ports Other interfaces Eight 4 Gbps FC expansion ports Four 10/100 Base-T Ethernet ports Two 9-pin RS-232 serial ports RAID level 0, 1, 3, 5, and 1+0 Cache battery backup Up to seven days (depending on cache size) Integrated data services/ premium features (optional) • Sun StorageTek™ Data Snapshot (optional) (support four snaps per volume, 1,024 per array) • Sun StorageTek™ Data Volume Copy (optional) (support eight active copies per volume, 1,024 per array) • Sun StorageTek™ Data Replicator (optional) (support 64 replicated volumes) • Sun StorageTek™ Storage Domain (4, 8, 16, or 64) Dynamic capacity expansion Five to 224 drives 365 GB to 168 TB Duration Phone support On-site service On-site response time Service upgrade Expansion tray Up to 14 CSM200 expansion modules Dimensions Dynamic reconfiguration Volume expansion, RAID migration, capacity expansion, segment size migration, volume and virtual disk reconfiguration, controller firmware upgrades Drive depopulation Scales from five to 16 hard disk drives per expansion module Volume Up to 2,048 Global hot spares Up to 15 Maximum array capacity 168 TB Height x width x depth Weight (maximum) 3.5 in., low-profile Interface Dual-ported Fibre Channel Supported drives/system per tray capacity (raw, unformatted) Fibre Channel drives SATA-II drives 73 GB 15,000-rpm 4 Gbps 146 GB 15,000-rpm 4 Gbps 146 GB 10,000-rpm 2 Gbps 300 GB 15,000-rpm 4 Gbps 300 GB 10,000-rpm 2 Gbps 500 GB 7,200-rpm 3 Gbps 750 GB 7,200-rpm 3 Gbps 1,168 GB per tray (3 RU) 2,336 GB per tray (3 RU) 2,336 GB per tray (3 RU) 4,800 GB per tray (3 RU) 4,800 GB per tray (3 RU) 8,000 GB per tray (3 RU) 12,000 GB per tray (3 RU) Supported software • • • • • • • • • • Sun StorageTek™ QFS Software Sun StorageTek™ SAM-FS Software Sun™ Cluster Software Sun StorageTek™ Enterprise Backup Software (EBS) Solstice™ DiskSuite 4.2.1 (in conjunction with the Solaris 8 Operating System) Solaris™ Volume Manager (embedded in the Solaris 9 Operating System) Symantec NetBackup (NBU) Symantec Volume Manager with DMP (VxVM) Symantec File System (VxFS) Symantec Storage Foundation Management software support The Sun StorageTek 6540 array is fully supported with major host operating systems and multipath drivers. For details, please refer to the Sun StorageTek Interop Tool at: https://extranet.stortek.com/interop/interop Host connectivity Host/HBA/FC switches AC power Three years 8 a.m.-8 p.m., Mon-Fri Next business day, 8 a.m.-5 p.m., Mon-Fri Next business day, local business hours SpectrumSM service upgrades are available Controller module: 17.5cm (6.9 in.) x 48.3cm (19.0 in.) x 65.1cm (25.6 in.) Expansion module: 12.95cm (5.1 in.) x 44.70cm (17.6 in.) x 57.15cm (22.5 in.) Cabinet: 188cm (74 in.) x 59.7cm (23.5 in.) x 100cm (39.4 in.) x 100cm (39.4 in.) Controller module: 36.5 kg (80.5 lbs.) Expansion module: 40 kg (88 lbs.) Cabinet: 364.5 kg (810 lbs.) cabinet only Controller module: 2.65 A max. operating at 240 V AC (180-264 V AC range), 50/60 Hz 5.53 A max. operating at 115 V AC (90–136 V AC range), 50/60 Hz Expansion module: 1.97 A max. operating at 240 V AC (180-264 V AC range), 50/60 Hz 4.11 A max. operating at 115 V AC (90–136 V AC range), 50/60 Hz Cabinet: 32 A (2 x 16 A) maximum, N+1/dual grid redundant systems, single-phase 180-240 V AC, 47-63 Hz Environment Operating temperature Relative humidity Shock Vibration Heat output 10° C to 40° C (50° to 104° F) 20–80 percent noncondensing Altitude 100 ft. (30.5m) below sea level to 9,840 ft. (3,000m) 25 G, 3.75 ms triangular Random vibration to specified power spectral density Controller module: 235 watts (804 BTU/hr.) Expansion module: 444 watts (1,517 BTU/hr.) Regulations Safety and emissions Immunity IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15 (47CFR15B), CISPR 22 (EN55022—RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3 CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000 4-6, IEC 61000-4-11 BOSTON Sun StorageTek Common Array Manager (included) SANtricity Storage Manager v9.16 (optional) CHICAGO Operating system support • Solaris™ Operating System 8, 9, 10, and x64 • Microsoft Windows 2000 Server and Advanced Server (SP4) • Microsoft Windows 2003 Server Standard, Enterprise, and Web editions • HP-UX 11.11 and 11.23 • IBM AIX 5.2, 5.3 • Red Hat Linux AS/ES/WS Enterprise edition 3.0/4.0 • SUSE Linux LES 8 and 9 • Netware 6 SP5, Netware 6.5 SP3 • SGI IRIX 6.5.28 • VMware ESX 3.0 https://extranet.stortek.com/interop/interop Warranty Power requirements Disk drives Form factor Systems and Network Integration Division DC NEW JERSEY Corporate Headquarters 175 Middlesex Turnpike PO Box 9137 Bedford, MA 01730-9137 Sun, Sun Microsystems, the Sun logo, Solaris, Solstice, Spectrum, StorageTek, and SunVIP are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All information is subject to change without notice. © 2008 Continental Resources, Inc. Specifications subject to change without notice. Continental Resources not responsible for typographical errors. All product and manufacturer names are trademarks or registered trademarks of their respective companies. Printed in U.S.A. CRI 0299-0815-0 new york city philadelphia/de valley www.conres.com 800-937-4688