Transcript
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users In view of the best solutions renewable energy for the production of heating and hot domestic water is born our patented SUPER HUB RADIATOR, able to meet all needs related to installations for medium to large users (apartment buildings, sports centers, campgrounds, hotels etc.). The main features of the SUPER HUB RADIATOR are: INTEGRATED SOLUTIONS The SUPER HUB RADIATOR is designed to operate as an accumulator of thermal energy, providing ample possibility of configuration in combination with solar thermal and biomass. HIGH PERFORMANCE The special construction of the condensers patented multiple on direct exchange refrigerant gas / water ensures higher yield (SCOP), high reliability and easy maintenance. NO LEGIONELLA The SUPER RADIATOR HUB with the method first in - first out will provide maximum return of the heat pump and maximum hygiene of the domestic circuit which is always separated from the technique water. These particular copper exchanger can eliminate in the bud the great problem of legionella.
B Made in Italy patent
RENEWABLE ENERGY
TAXES REDUCING
HIGH EFFICIENCY
ENERGY SAVING
ENERGY SAVING The exclusive patent HUB Radiator redefines the performance parameters of the heat pump air / water going to catch up with the “direct exchange of the condenser coolant / water” the highest levels of system performance even with harsh winters. Specification and design of the Moto-evaporating (Booster)
60° ECOLOGIC GAS
PHOTOVOLTAIC COMBINATION
DHW WITHOUT LEGIONELLA
HEATING 60 °C
The range of the Moto-evaporating external (Booster)
comprises 5 units from 3.0 to 16.6 kW thermal and 1 unit built from 3.0 kW thermal. The booster is composed of series of a heat exchanger direct immersion pre-assembled on the flange and an electrical control panel and control. The user can request the installation of heat exchangers / additional capacitors onboard inertial technical accumulation to be connected later to other Booster. The booster is controlled by a microprocessor electronic control modulating which maximizes efficiency and allows it to function properly both in winter and in summer (auto-adaptive multiple independent circuits). The booster can be supplied in two different versions below: 1) Booster mono compressor outdoor A or recessed B Booster represented in figure A has been realized for installations with wall brackets or placed on the floor. Booster represented in figure B has been designed to be inserted recessed inside the building when, for aesthetic reasons or landscape restrictions you can not use a standard unit from outside. 2) Booster multi compressor outdoor C D You may work in this case with: - N. 2 steps of capacity load (100% - 50% - 0%) with 2 compressors and 2 circuits separate and independent C . - n. 3 gradini di parzalizzazione di carico (100% - 66% - 33% - 0%) N. 3 steps of partialization load (100% - 66% - 33% - 0%) with 3 compressors and 3 separate circuits and independent in model in 3 Booster D .
Moto-evaporating A External (1 Booster) Mono compressor HR 3.0 / 7.8
Moto-evaporating B Recessed (1 Booster) Mono compressor HR 3.0
Moto-evaporating A External (1 Booster) Mono vcompressor HR 5.2 / 8.3
Moto-evaporating C external (2 Booster) 2 circuits with two compressors HR 16.6 36
Moto-evaporating D external (3 Booster) three compressors 3 independent circuits with 3 steps partialization (100% -66% -33% -0%) 23.4 kW Total
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users
inertial accumulation (unit) versions A_RM1 - A_RM2 - A_RM3
Exchanger Biomass top
Version A_RM3
Version A_RM2
Version A_RM1
Quick DHW exchanger finned copper
Exchanger Inferior solar
Specification and design of the technical inertial tanks
Technical accumulations in the range SUPER HUB RADIATOR 300 to 2,000 liters are made with special insulation and further finish coating colored PVC. The tank is in carbon steel painted outside with rust. The accumulations are made in three different versions: - A_RM1 (accumulation technical water with top flange and removable exchanger DHW series) - A_RM2 (accumulation technical water with solar heat exchanger fixed lower, upper flange and removable exchanger DHW series) - A_RM3 (accumulation technical water with solar heat exchanger fixed lower, fixed exchanger for higher biomass and upper flange and exchanger removable DHW series) Using the same flange will fit depending on the configuration required exchangers refrigerant / water direct exchange to be connected with external drives (Booster) in heat pump.
Model Outdoor Booster 3.0 HR heating Recessed Booster 3.0 HR heating Outdoor Booster 5.2 HR heating Outdoor Booster 7.8 HR heating Outdoor Booster 8.3 HR heating Outdoor Booster 16.6 HR heating Accumulate A_RM1 300 l Accumulate A_RM1 500 l Accumulate A_RM1 800 l Accumulate A_RM1 1000 l Accumulate A_RM1 1500 l Accumulate A_RM1 2000 l Accumulate A_RM2 300 l Accumulate A_RM2 500 l Accumulate A_RM2 800 l Accumulate A_RM2 1000 l Accumulate A_RM2 1500 l Accumulate A_RM2 2000 l Accumulate A_RM3 300 l Accumulate A_RM3 500 l Accumulate A_RM3 800 l Accumulate A_RM3 1000 l Accumulate A_RM3 1500 l Accumulate A_RM3 2000 l
Thermal power kW3,0 3,0 5,2 7,8 8,3 16,6
Quick DHW exchanger
Exchanger solar
Exchanger Biomass
Extractable da 4,54 m2
-
-
Extractable da 4,54 m2
-
-
Extractable da 5,26 m2
-
-
Extractable da 5,26 m2
-
-
Extractable da 6,34 m2
-
-
Extractable da 6,34 m2
Fixed da 1,60 m2
-
Extractable da 4,54 m2
Fixed da 2,00 m2
-
Extractable da 4,54 m2
Fixed da 2,70 m2
-
Extractable da 5,26 m2
Fixed da 3,50 m2
-
Extractable da 5,26 m2
Fixed da 4,50 m2
-
Extractable da 6,34 m2
Fixed da 4,80 m2
-
Extractable da 6,34 m2
Fixed da 1,60 m2
-
Extractable da 4,54 m2
Fixed da 2,00 m2
Fixed da 1,20 m2
Extractable da 4,54 m2
Fixed da 2,70 m2
Fixed da 1,80 m2
Extractable da 5,26 m2
Fixed da 3,50 m2
Fixed da 2,10 m2
Extractable da 5,26 m2
Fixed da 4,50 m2
Fixed da 2,50 m2
Extractable da 6,34 m2
Fixed da 4,80 m2
Fixed da 3,20 m2
Extractable da 6,34 m2
Fixed da 4,00 m2 37
Code 76010240 76010280 76010400 76010500 76010600 76010700
€ 1.880,00 4.400,00 3.040,00 3.280,00 4.740,00 8.940,00
37310300 37310500 37310800 37311000 37311500 37312000 37320300 37320500 37320800 37321000 37321500 37322000 37330300 37330500 37330800 37331000 37331500 37332000
2.760,00 2.940,00 3.900,00 4.152,00 4.880,00 6.140,00 3.042,00 3.466,00 4.260,00 4.340,00 6.100,00 6.600,00 3.240,00 3.898,00 4.500,00 4.780,00 6.600,00 6.900,00
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Accessories SUPER HUB RADIATOR
Codice
€
75050102 75050103 75060300
144,00 152,00 290,00
Circulator electronic inverter additional max 3.3 m3 / h max head 6.2 m power consumption min. 4 W - 45 W max
35006001
214,00
Pump installation kit that includes: circulation pump electronic inverter complete shut-off valves, valve jolly air vent, safety valve, threaded plugs and wells probe holders
75100011
380,00
Mixing valve fixed point for radiant systems at low temperature
75100003
200,00
Wall thermostat to control circulating pump with digital display
75100007
120,00
AIR BOX cupboard cylindrical unit outer frame cover technical accumulation
75060202 75060203 75060204
620,00 990,00 1.100,00
RACK 3 closet External Drive Booster mod. 3.0 - 5.2 - 7.8 H 2100 - L 960 - D 540
75060206
1.180,00
Control panel and remote control wall or recessed
75100005
228,00
37081060 37081061
78,00 114,00
mod. 1500 W mod. 2000 W mod. 3000 W
Single-phase 230 V electrical heater degree of protection IP 65
P 930 H 1950 mod. 300 L 950 P 930 H 1950 mod. 500 L 950 mod. 800 L 1200 P 1180 H 2100
Bracket for external Booster including rubber anti-vibration
mod. Booster 3.0 mod. Booster 5.2-7.8-8.3
Support base with anti-vibration for external Booster
Additional capacitor
75100020
384,00
26505565
300,00
Booster for just hot
75100001
184,00
Vibration damper kit for floor installation
75100021
62,00
Kit timer
35639900
110,00
38
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Kit solar thermal system to be integrated with HUB RADIATOR SUPER 1
The tank A_RM2 is arranged to be easily integrated with our kits solar thermal thanks to a heat exchanger lower fixed mounted on board. All booster will be connected to the tanks through a dedicated technical exchanger condenser direct coolant / water that will be managed as a single and independent circuit. The possible combinations are as follows: - Kit solar thermal with storage A_RM2 500 liters that can connect up to a maximum of 4 Boosters (Boosters have 4 separate and independent circuits to work on 4 capacity steps) - Kit solar thermal with storage A_RM2 800 liters that can connect up to 6 Booster. (Boosters have 6 separates and independents circuits to work on 6 capacity steps) - Solar thermal kit with accumulations A_RM2 from 1000-1500-2000 liters that can connect up to 8 Boosters. (Boosters have 8 separate circuits and independent work on 8 capacity steps)
2
Solar thermal kit 3 x 2,5 m2 500 liters - Accumulation technical inertial A_RM2 500 liters (Fig. 1) - N. 3 in flatbed SELECTIVE 2.5 m2 (Fig. 2) - Anchor Kit 3 collectors SELECTIVE 2.5 m2 (Fig. 3) - Solar station 2-way model. UNIT 2 (Fig. 4) Models - MULTI CONTROL Solar control unit (Fig. 5) - Solar expansion tank 40 liters (Fig. 6) Kit da 3 x 2,5 - 500 l Flat roof - Fittings kit string (string 1 - 3 collectors) (Fig. 7) Kit da 3 x 2,5 - 500 l Pitched roof - Removable DHW exchanger 4,54 m2 (Fig. 8)
3
4
5
6
7
8
Code 75050300 75050301
€ 7.796,00 7.664,00
Solar thermal kit 5 x 2,5 m2 800 liters - Accumulation technical inertial A_RM2 800 liters (Fig. 1) - N. 5 in flatbed SELECTIVE 2.5 m2 (Fig. 2) - Anchor Kit 5 collectors SELECTIVE 2.5 m2 (Fig. 3) - Solar station 2-way model. UNIT 2 (Fig. 4) - MULTI CONTROL Solar control unit (Fig. 5) Models - Solar expansion tank 60 liters (Fig. 6) Kit 5 x 2,5 - 800 l Flat roof - Fittings kit string (string 1 - 5 collectors) (Fig. 7) - Removable DHW exchanger 5,26 m2 (Fig. 8) Kit 5 x 2,5 - 800 l Pitched roof
Code 75050400 75050401
€ 11.004,00 10.804,00
Solar thermal kit 6 x 2,5 m2 1000 liters - Accumulation technical inertial A_RM2 1000 liters (Fig. 1) - N. 6 in flatbed SELECTIVE 2.5 m2 (Fig. 2) - Anchor Kit 6 collectors SELECTIVE 2.5 m2 (Fig. 3) - Solar station 2-way model. UNIT 2 (Fig. 4) - MULTI CONTROL Solar control unit (Fig. 5) Models - Solar expansion tank 60 liters (Fig. 6) Kit 6 x 2,5 - 1000 l Flat roof - Fittings kit string (string 1 - 6 collectors) (Fig. 7) Kit 6 x 2,5 - 1000 l Pitched roof - Removable DHW exchanger 5,26 m2 (Fig. 8)
Code 75050500 75050501
€ 12.196,00 11.932,00
Solar thermal kit 10 x 2,5 m2 1500 liters - Accumulation technical inertial A_RM2 1500 liters (Fig. 1) - N. 10 in flatbed SELECTIVE 2.5 m2 (Fig. 2) - Anchor Kit 10 collectors SELECTIVE 2.5 m2 (Fig. 3) - Solar station 2-way model. UNIT 2 (Fig. 4) - MULTI CONTROL Solar control unit (Fig. 5) Models - Solar expansion tank 100 liters (Fig. 6) Kit 10 x 2,5 - 1500 l Flat roof - Fittings kit string (string 2 - 10 collectors) (Fig. 7) - Removable DHW exchanger 6,34 m2 (Fig. 8) Kit 10 x 2,5 - 1500 l Pitched roof
Code 75050600 75050601
€ 19.132,00 18.636,00
Solar thermal kit 12 x 2,5 m2 2000 liters - Accumulation technical inertial A_RM2 2000 liters (Fig. 1) - N. 12 in flatbed SELECTIVE 2.5 m2 (Fig. 2) - Anchor Kit 12 collectors SELECTIVE 2.5 m2 (Fig. 3) - Solar station 2-way model. UNIT 2 (Fig. 4) - MULTI CONTROL Solar control unit (Fig. 5) Models - Solar expansion tank 100 liters (Fig. 6) Kit 12 x 2,5 - 2000 l Flat roof - Fittings kit string (string 2 - 12 collectors) (Fig. 7) Kit 12 x 2,5 - 2000 l Pitched roof - Removable DHW exchanger 6,34 m2 (Fig. 8)
Code 75050700 75050701
€ 21.830,00 20.756,00
39
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Dimensions Booster external HR 3.0 - 7.8 P
Dimensions Booster recessed HR 3.0
L
H
140
Dimensions Booster external HR 5.2 - 8.3
Dimensions Booster external HR 16.6 bicompressore
L
Booster
L
H
P
kg
HR 3.0 external
700
552
256
33
HR 3.0 external
590
400
230
35
HR 5.2 external
950
690
360
55
HR 7.8 external
902
650
307
55
HR 8.3 external
925
872
368
76
HR 16.6 external
925
1640
368
140
Values in mm
Overall dimensions and technical data solar collector SELECTIVE 2.5
2005
1880
1340
100
22
1290
DESCRIPTION Weight Tube collector Length tube Distance tube Case material Insulation thickness Glass Absorbing surface net Aperture area Total surface collector Surface treatment Efficiency (aperture) Loss coefficient (opening) Absorption Issue Recommended flow / panel Water capacity collector Maximum operating pressure Stagnation temperature 40
U.M. kg mm mm mm mm
SELECTIVE 2.5 50 22 1340 1880 Aluminum 45 Extra-clear, tempered, prismatic
m2 m2 m2
2,30 2,35 2,59 Selective TITAN (titanium oxide)
η0 α1 / α2 % % l/h l bar °C
0,716 3,87 / 0,0069 95 4,7 130 2 10 192
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Technical inertial accumulation (unit) versions A_RM1 - A_RM2 - A_RM3
A_RM1
A_RM2
A_RM3
Dimensions inertial accumulation
U.M.
300
500
800
1000
1500
2000
De
mm
600
750
990
990
1200
1300
Di
mm
500
650
790
790
1000
1100
H
mm
1580
1650
1700
2080
2135
2455
C
mm
215
240
275
275
360
365
E
mm
680
615
655
810
785
925
F
mm
1080
1105
1145
1355
1285
1495
I
mm
1350
1375
1410
1755
1745
2050
L
mm
280
340
350
350
440
445
M
mm
800
860
870
1035
1100
1085
N
mm
900
960
975
1295
1265
1495
O
mm
1260
1320
1325
1775
1665
1975
X-Y-G-D
”
1
1
1
1
1
1
A
”
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
B
”
1/2
1/2
1/2
1/2
1/2
1/2
Surface removable DHW (1)
m2
4,5
4,5
5,2
5,2
6,3
6,3
Surface footer exchanger (2)
m2
1,6
2,0
2,7
3,5
4,5
4,8
Surface fixed top exchanger (3)
m2
1,2
1,8
2,1
2,5
3,2
4,0
Insulation thickness
mm
50
50
100
100
100
100
pressure accumulation
bar
4
4
4
4
4
4
Max working temperature
°C
95
95
95
95
95
95
pressure fixed exchangers
bar
12
12
12
12
12
12
Empty weight A_RM1
kg
81
115
148
186
232
308
Empty weight A_RM2
kg
92
129
168
208
260
356
Empty weight A_RM3
kg
101
143
186
231
288
386
41
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Hydraulic connection diagram example for heating / DHW with: SUPER HUB RADIATOR, heating stove pellets DOMUS hydro and solar thermal Booster mono compressor mod. HR 7.8
1 Vent valve 2 Pressure reducer 3 System pump 4 Safety valve 5 Supply hot water DHW 6 Expansion vase 7 Thermostat of ambiance 8 Shut-off valve 9 Backflow for water networks 10 Line filter 11 Switchboard double Booster 12 Solar controller CONTROL MULTI 13 Solar station 2-way 2 UNIT 14 Safety exhaust system water 15 Mixing valve DHW 16 Thermo hydro DOMUS pellets
Solar thermal collector
Thermal storage inertial A_RM2
Heating stove hydro DOMUS PELLET
Examples of production DHW with finned exchanger and accumulation at 58 °C Capacity accumulation 300 l 500 l 800 l 1000 l 1500 l 2000 l
exchanger surface 4,54 m2 4,54 m2 5,26 m2 5,26 m2 6,34 m2 6,34 m2
Booster HR installed 7.8 7.8 + 3.0 7.8 + 7.8 7.8 + 7.8 + 7.8 16.6 + 16.6 16.6 + 16.6 + 16.6
DHW production at 40 °C 220 l/h 260 l/h 340 l/h 540 l/h 890 l/h 1220 l/h
Hypothesis of thermal efficiency with fixed footer exchanger Capacity accumulation exchanger surface Power* Capacity 2 300 l 1,6 m 14 kW 620 l/h 500 l 2,0 m2 21 kW 880 l/h 800 l 2,7 m2 26 kW 1090 l/h 1000 l 3,5 m2 28 kW 1310 l/h 1500 l 4,5 m2 37 kW 1720 l/h 2000 l 4,8 m2 42 kW 1880 l/h * Hypothesis of thermal efficiency with temperature 80/60 °C (side exchanger) - 50/70 °C (tank side)
Pressure Drop 2 kPa 4 kPa 5 kPa 6 kPa 8 kPa 10 kPa
Ipotesi resa termica scambiatore fisso superiore Capacity accumulation exchanger surface Power* Capacity 2 300 l 1,2 m 8 kW 400 l/h 500 l 1,8 m2 18 kW 700 l/h 800 l 2,1 m2 20 kW 900 l/h 2 1000 l 2,5 m 24 kW 1100 l/h 1500 l 3,2 m2 30 kW 1400 l/h 2000 l 4,0 m2 36 kW 1600 l/h * Hypothesis of thermal efficiency with temperature 80/60 °C (side exchanger) - 50/70 °C (tank side) 42
Pressure Drop 1 kPa 3 kPa 3 kPa 6 kPa 8 kPa 10 kPa
SUPER HUB RADIATOR
Patented high-efficiency heat pump to direct exchange refrigerant gas / water to produce heating and hot water for medium and large users Technical data table SUPER HUB RADIATOR DESCRIPTION Thermal power air 7 °C / water 35 °C COP Thermal power air 2 °C / water 35 °C COP Thermal power air 7 °C / water 45 °C COP Thermal power air 2 °C / water 45 °C COP
U.M.
HR 3.0
HR 5.2
HR 7.8
HR 8.3
HR 16,6
HR 3.0 INC.
kW
3,11
5,51
8,12
9,12
18,24
3,12
W/W
4,12
4,11
4,10
4,10
4,10
3,95
kW
2,72
4,82
7,10
7,99
15,98
2,73
W/W
3,67
3,57
3,59
3,52
3,52
3,43
kW
2,97
5,25
7,75
8,68
17,36
2,98
W/W
3,16
3,07
3,07
3,01
3,01
2,95
kW
2,61
4,62
6,80
7,65
15,30
2,62
W/W
2,76
2,68
2,70
2,64
2,50
2,58
2
1
Water temperature max
°C
Fans
n.
58 1
Air temperature
max
°C
45
42
min
°C
- 12
-7
Rotary
Compressor type
R410A
Refrigerant
230V/1/50Hz
Power supply Current consumption in heating*
A
4,19
7,20
11,49
13,20
11,41
4,20
IP 24
Degree of protection Connecting the water plant
”
3/4
Hydraulic connection for filling
”
1/2
Connecting hot water
1/2
”
Connection refrigerant
liquid
”
1/4
1/4
3/8
3/8
2x3/8
1/4
gas
”
3/8
1/2
5/8
5/8
2x5/8
1/2
50
52
57
60
52
Maximum length of refrigerant pipes Sound pressure**
15
m dB(A)
58
10
Water quantity in single drawdown to 40 °C - 300 l
l
130
132
Water amount, in single drawdown at 40 °C - 500 l
l
216
220
Water quantity in single drawdown to 40 °C - 800 l
l
346
352
Water quantity in single drawdown to 40 °C - 1000 l
l
434
450
Water quantity in single drawdown to 40 °C - 1500 l
l
650
675
Water quantity in single drawdown to 40 °C - 2000 l
l
866
902
Recovery time from 10 to 58 °C - 300 l
h
5,18
5,21
3,11
2,06
1,01
5,18
Recovery time from 10 to 58 °C - 500 l
h
8,63
8,68
4,94
3,44
1,68
8,63
Recovery time from 10 to 58 °C - 800 l
h
-
-
8,29
5,49
2,69
-
Recovery time from 10 to 58 °C - 1000 l
h
-
-
-
6,86
3,36
-
Recovery time from 10 to 58 °C - 1500 l
h
-
-
-
10,29
5,06
-
Recovery time from 10 to 58 °C - 2000 l
h
-
-
-
-
6,73
-
Recovery time from 46 to 58 °C - 300 l
h
1,78
1,81
1,08
0,72
0,34
1,78
Recovery time from 46 to 58 °C - 500 l
h
2,98
3,01
1,79
1,20
0,56
2,98
Recovery time from 46 to 58 °C - 800 l
h
-
-
2,87
1,92
0,91
-
Recovery time from 46 to 58 °C - 1000 l
h
-
-
-
2,40
1,13
-
Recovery time from 46 to 58 °C - 1500 l
h
-
-
-
3,60
1,70
-
Recovery time from 46 to 58 °C - 2000 l
h
-
-
-
-
2,26
-
Data referred to the following operating conditions *Winter heating: external air temperature 7 °C db - 6 °C B.U., storage temperature 55 °C **Measured in free field conditions with a reference distance of one meter