Preview only show first 10 pages with watermark. For full document please download

Supersafe Tm

   EMBED


Share

Transcript

The SuperSafe TM range offers the ideal solution for large capacity, modular, valve regulated lead acid battery requirements. SuperSafe RANGE SUMMARY TM's modular design concept, with its integral racking system provides a cost effective compact battery solution combined with a quick, simple on site installation process. SuperSafe TM's extra thick positive grids provide excellent performance and service life across an extensive range of applications including, telecommunications, power generation/distribution sites, both low and high rate UPS and emergency lighting. SuperSafe TM's utilize the proven AGM gas recombination technology, removing the need for the addition of water to any cell throughout it's operational life, which provides for battery solutions not requiring a separate battery room and only minimal maintenance. Features & Benefits ● Capacity range: 200Ah - 5000Ah ● Side or top terminations depending on configuration ● Front connections provide excellent maintenance access ● UL94 V-0 rated flame retardant container and lid as standard ● 100% nominal C10 capacity check prior to despatch ● Proven in service Publication No: AS-ML-TM-RS-001 May 2004 Construction Ring burn terminal seal with secondary epoxy resin seal, 100% factory tested and proven in service ● Self regulating pressure relief valve with integral flame arrestor ● Extra thick lead-calcium-tin positive grids to minimize corrosion and prolong service life ● Balanced lead-calcium negative grids to optimize recombination efficiency ● Separator of low resistance microporous fibre glass material within which the electrolyte is fully absorbed thus preventing acid spills in the case of accidental damage ● Container and heat sealed lid in UL94 V-0 rated flame retardant polypropylene as standard ● Cells housed in steel modules complete with integral racking system ● Seismic Zone 4 UBC 1997 approved racking optional on many configurations ● Terminals with a large surface area copper insert to provide maximum conductivity ● Installation & Operation Recommended float charge voltage; 2.280vpc at 20℃, 2.265vpc at 25℃ ● The SuperSafe TM range is designed for horizontal installation and can be installed safely within equipment rooms. A separate ● dedicated battery room is not necessary ● Six month shelf life at 20℃ ● Minimal maintenance; no addition of water required Standards Compliant with international standard IEC 60896-22 ● Classified as "Long Life" according to Eurobat Guide 1999 ● Approved to be shipped as non-hazardous cargo in accordance with the requirements of IMDG (International Maritime Code for Dangerous Goods) and OICA ( Organization of International Civil Aviation) ● UL recognised component ● ALL cells are proven to have 100% of rated C10 capacity in the factory prior to dispatch ● All EnerSys production facilities worldwide are certified to ISO 9001 ● General Specifications Type 12TM-200 12TM-300 12TM-500 12TM-600 6TM-400 6TM-850 6TM-1000 6TM-1000A 6TM-1100 6TM-1200 6TM-1300 6TM-1360 6TM-1500 6TM-1600 6TM-1700 4TM-2000 2TM-2600 2TM-3000A 2TM-3000 2TM-3600 2TM-4000 2TM-4500 2TM-5000 Nominal Voltage (V) 12 12 12 12 6 6 6 6 6 6 6 6 6 6 6 4 2 2 2 2 2 2 2 8hr rate to 1.75Vpc @ 77 F 200 300 500 600 400 850 1000 1000 1100 1200 1300 1360 1500 1600 1700 2000 2600 3000 3000 3600 4000 4500 5000 200 300 500 580 400 840 1000 1000 1080 1200 1300 1360 1500 1600 1640 2000 2600 3000 3000 3600 4000 4500 4920 O Length Depth(1) Height(2) Typical Weight(3) KG Short Circuit Current (A) Internal Resistance (m ) 665 893 957 1071 623 801 915 801 972 915 972 1145 915 1145 972 791 676 801 638 915 791 915 972 330 330 516 516 330 516 516 584 516 584 584 516 558 584 558 558 584 584 558 584 558 558 558 218 218 218 218 218 218 218 218 218 218 218 218 278 218 278 278 218 218 278 218 278 278 278 108 158 239 281 107 203 234 235 255 269 287 316 359 369 386 307 196 235 245 369 307 359 386 2746 3882 5180 6090 3985 7980 9275 7212 9673 8219 8571 10453 10733 11057 11215 17467 17391 22222 21978 25000 26667 32780 34483 4.370 3.090 2.310 1.970 1.500 0.750 0.640 0.832 0.620 0.730 0.700 0.570 0.560 0.540 0.535 0.229 0.115 0.090 0.091 0.080 0.075 0.061 0.058 O Notes: 1) The depth shown in the table is for the module only. Add 86mm to obtain the overall depth including the front panel. 2) To calculate the total height of a battery stack multiply the module height by the number of modules in the stack and add 100mm for the base support except for the TM - 1500, 1700, 2000, 3000, 4000, 4500 and 5000 modules where 120mm must be added. 3) The typical weight of the module excludes the connectors, terminal plates , front panels and base support. 4) SuperSafe TM batteries are designed for horizontal installation only. 5) The excellent flexibility afforded by the modular construction design provides for further combinations of capacity, voltage or footprint in addition to those illustrated in the above tabulation,eg 2TM-3200, 2TM-4800,4TM-1000,4TM-1700 etc. Contact: www.enersys.com Global Headquarters P.O. Box 14145 Reading PA 196212-4145 USA Tel: +1-610-208-1991 +1-800-538-3627 Fax: +1-610-372-8613 EnerSys EMEA Houtweg 26 1140 Brussels Belgium Tel: +32 (0)2 247 94 47 Fax: +32 (0)2 247 94 49 EnerSys Asia 49, Yanshan Road Shekou, Shenzhen Guangdong 518067 China Tel: +86-755-2689 3639 Fax: +86-755-2689 8013 Publication No: AS-ML-TM-RS-001 May 2004-Subject to revisions without prior notice Nominal Dimensions (mm) Nominal Capacity (Ah) 10hr rate to 1.80Vpc @ 25 C