Preview only show first 10 pages with watermark. For full document please download

Superserver - Industrial Computers, Inc.

   EMBED


Share

Transcript

SuperServer® 6019P-WT/WTR USER’S MANUAL Revision 1.0a The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our website at www.supermicro.com. Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/ or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license. IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”. WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm. The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale. Manual Revision 1.0a Release Date: October 03, 2017 Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright © 2017 by Super Micro Computer, Inc. All rights reserved. Printed in the United States of America SuperServer 6019P-WT/WTR User's Manual Preface About this Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6019P-WT/WTR. Installation and maintenance should be performed by experienced technicians only. Please refer to the 6019P-WT/WTR server specifications page on our website for updates on supported memory, processors and operating systems (http://www.supermicro.com). Notes For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server. • Supermicro product manuals: http://www.supermicro.com/support/manuals/ • Product drivers and utilities: ftp://ftp.supermicro.com • Product safety info: http://www.supermicro.com/about/policies/safety_information.cfm If you have any questions, please contact our support team at: [email protected] This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Warnings Special attention should be given to the following symbols used in this manual. Warning! Indicates important information given to prevent equipment/property damage or personal injury. Warning! Indicates high voltage may be encountered when performing a procedure. 3 Preface Contents Chapter 1 Introduction 1.1 Overview................................................................................................................................8 1.2 Unpacking the System..........................................................................................................8 1.3 System Features...................................................................................................................9 1.4 Server Chassis Features.....................................................................................................10 Control Panel.....................................................................................................................10 Chassis Front.....................................................................................................................11 Chassis Rear......................................................................................................................12 1.5 Motherboard Layout............................................................................................................13 Quick Reference Table.......................................................................................................14 Chapter 2 Server Installation 2.1 Overview..............................................................................................................................17 2.2 Preparing for Setup.............................................................................................................17 Choosing a Setup Location................................................................................................17 Rack Precautions...............................................................................................................17 Server Precautions.............................................................................................................18 Rack Mounting Considerations..........................................................................................18 Ambient Operating Temperature.....................................................................................18 Airflow.............................................................................................................................18 Mechanical Loading........................................................................................................18 Circuit Overloading.........................................................................................................19 Reliable Ground..............................................................................................................19 2.3 Installing the Rails...............................................................................................................20 Identifying the Sections of the Rack Rails.........................................................................20 Installing the Outer Rails....................................................................................................20 2.4 Installing the Server into a Rack.........................................................................................21 Installing to a Standard Rack.............................................................................................21 Installing to a Telco Rack...................................................................................................21 Chapter 3 Maintenance and Component Installation 3.1 Removing Power.................................................................................................................24 3.2 Accessing the System.........................................................................................................24 3.3 Motherboard Components...................................................................................................25 Processor and Heatsink Installation...................................................................................25 4 SuperServer 6019P-WT/WTR User's Manual Removing the Dust Cover from the CPU Socket...........................................................25 Processor Package Assembly........................................................................................26 Processor Heatsink Module (PHM)................................................................................27 Removing the Processor Heatsink Module (PHM).........................................................28 Memory Support.................................................................................................................29 DIMM Population Requirements........................................................................................30 DIMM Installation...............................................................................................................33 DIMM Removal..................................................................................................................33 PCI Expansion Card Installation........................................................................................34 Motherboard Battery..........................................................................................................34 3.4 Chassis Components..........................................................................................................35 Front Bezel.........................................................................................................................35 Hard Drives........................................................................................................................35 Hard Drive Carrier Indicators..........................................................................................36 DVD-ROM Drive Installation..............................................................................................37 System Cooling..................................................................................................................37 Replacing a Failed Fan..................................................................................................37 Power Supply: 6019P-WT..................................................................................................39 Power Supply Failure.....................................................................................................39 Power Supply: 6019P-WTR...............................................................................................39 Power Supply Failure.....................................................................................................39 Chapter 4 Motherboard Connections 4.1 Power Connections.............................................................................................................41 4.2 Headers and Connectors....................................................................................................42 Control Panel..................................................................................................................45 4.3 Ports....................................................................................................................................49 Rear I/O Ports.................................................................................................................49 Ethernet Ports.................................................................................................................50 4.4 Jumpers...............................................................................................................................51 Explanation of Jumpers..................................................................................................51 4.5 LED Indicators.....................................................................................................................54 Chapter 5 Software 5.1 OS Installation.....................................................................................................................56 Installing the Windows OS for a RAID System.................................................................56 Installing Windows to a Non-RAID System.......................................................................56 5 Preface 5.2 Driver Installation.................................................................................................................57 5.3 SuperDoctor® 5....................................................................................................................58 Chapter 6 BIOS 6.1 Introduction..........................................................................................................................59 6.2 Main Setup..........................................................................................................................60 6.3 Advanced Setup Configurations..........................................................................................62 6.4 Event Logs...........................................................................................................................90 6.5 IPMI......................................................................................................................................92 6.6 Security ..............................................................................................................................95 6.7 Boot ....................................................................................................................................99 6.8 Save & Exit........................................................................................................................101 Appendix Appendix Appendix Appendix A BIOS Codes B Standardized Warning Statements for AC Systems C System Specifications D UEFI BIOS Recovery 6 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information) [email protected] (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: [email protected] (General Information) [email protected] (Technical Support) [email protected] (Customer Support) Website: www.supermicro.nl Asia-Pacific Address: Super Micro Computer, Inc. 3F, No. 150, Jian 1st Rd. Zhonghe Dist., New Taipei City 235 Taiwan (R.O.C) Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3992 Email: [email protected] Website: www.supermicro.com.tw 7 SuperServer 6019P-WT/WTR User's Manual Chapter 1 Introduction 1.1 Overview This chapter provides a brief outline of the functions and features of the 6019P-WT/WTR. The 6019P-WT/WTR is based on the X11DDW-L motherboard and the SC815TQC-605WB/R706WB chassis. In addition to the motherboard and chassis, several important parts that are included with the system are listed below. Main Parts List Description Part Number Quantity Passive Heatsink for 1U System SNK-P0067PSMB 2 4-cm Cooling Fan FAN-0156L4 4 Backplane BPN-SAS3-815TQ 1 Hot-swap Hard Drive Trays MCP-220-00075-0B 4 Air Shroud MCP-310-19019-0B 2 Riser Card RSC-R1UW-E8R 1 Riser Card RSC-R1UW-2E16 1 Rack Rail Mounting Kit MCP-290-00054-0N 1 1.2 Unpacking the System Inspect the box the SuperServer 6019P-WT/WTR was shipped in and note if it was damaged in any way. If any equipment appears damaged, please file a damage claim with the carrier who delivered it. Decide on a suitable location for the rack unit that will hold the server. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. It will also require a grounded AC power outlet nearby. Be sure to read the precautions and considerations noted in Appendix B. 8 Chapter 1: Introduction 1.3 System Features The following table provides you with an overview of the main features of the 6019P-WT/WTR. Please refer to Appendix C for additional specifications. System Features Motherboard X11DDW-L Chassis SC815TQC-605WB/R706WB (6019P-WT/WTR, respectively) CPU Dual Intel® Xeon® Scalable processors Socket Type Socket P Memory Supports up to 1.5 TB of registered ECC DDR4-2666 RDIMM or LRDIMM memory Chipset Intel C621 chipset Expansion Slots One PCI-E 3.0 x32 slot with riser card (RSC-R1UW-2E16) One PCI-E 3.0 x16 slot mezzanine with SAS support One PCI-E 3.0 x16 slot with riser card (RSC-R1UW-E8R) Hard Drives Four 3.5" hot-swap hard drives Power 6019P-WT: single 600W power supply module 6019P-WTR: dual 700/750W power supply modules Form Factor 1U rackmount Dimensions (WxHxD) 17 x 1.7 x 25.6 in. (432 x 43 x 650 mm) 9 SuperServer 6019P-WT/WTR User's Manual 1.4 Server Chassis Features Control Panel The switches and LEDs located on the control panel are described below. See Chapter 4 for details on the control panel connections. 1 2 3 4 5 6 7 8 Figure 1-1. Control Panel View Control Panel Features Item Feature Description 1 UID Button Depressing the UID (unit identifier) button illuminates an LED on both the front and rear of the chassis for easy system location in large stack configurations. The LED will remain on until the button is pushed a second time. 2 Universal Information LED See table below for details. 3 NIC2 LED Indicates network activity on LAN port 2 when flashing 4 NIC1 LED Indicates network activity on LAN port 1 when flashing 5 HDD LED Indicates activity on a hard drive when flashing. 6 Power LED Indicates power is being supplied to the system power supply. This LED should normally be illuminated when the system is operating. 7 Reset Button The reset button is used to reboot the system Power Button The main power button is used to apply or remove power from the power supply to the server. Turning off system power with this button removes the main power but maintains standby power. To perform many maintenance tasks, you must also unplug system before servicing 8 Information LED Status Description Continuously on and red An overheat condition has occurred. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Solid blue Local UID has been activated. Use this function to locate the server in a rackmount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location. 10 Chapter 1: Introduction Chassis Front The SC815TQC-605WB/R706WB is a 1U rackmount chassis See the illustration below for the features included on the front of the chassis. 3 2 1 4 1 1 1 Figure 1-2. Chassis Front View Front Chassis Features Item Feature Description 1 Hard Drive Carrier Carrier for hot-swap hard drive 2 DVD ROM Drive (Optional) slim DVD-ROM drive 3 Control Panel Front control panel with LEDs and buttons (see preceding page) 4 Rack Ear Brackets Secures the server chassis to the rack 11 4 SuperServer 6019P-WT/WTR User's Manual Chassis Rear The illustration below shows the features included on the rear of the chassis. Note: the 6019P-WTR server is shown below. The 6019P-WT is the same but with a single power module only. 3 1 1 2 4 4 Figure 1-3. Chassis Rear View Rear Chassis Features Item Feature Description 1 Power Supply Redundant 700W Platinum Level power supply (6019P-WTR) Single 600W Platinum Level power supply (6019P-WT) 2 I/O Back Panel Rear I/O ports (see Section 4.3) 3 Expansion Card Slot Slot for two expansion cards (requires pre-installed riser cards) 4 Rack Ear Brackets Secures the server chassis to the rack 12 Chapter 1: Introduction 1.5 Motherboard Layout Below is a layout of the X11DDW-L with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4. IPMI LAN LE1 USB0/1 LAN1 LAN2 USB2/3` JUIDB1 JPME1 JPME2 LE1 C JUIDB1 IPMI_LAN USB0/1(3.0) JPG1 JBR1 JPL1 JWD1 JIPMB1 S-SATA5 LAN1 S-SATA4 BMC S-SATA 0~3 I-SATA 0~3 JBT1 I-SATA 4~7 CPU2_PORT2D JBMC_DEBUG JD1 + 1 JSDCARD1 JAOM JF1 LE2 PWRRST PS UID NIC NIC HDD PWR X NMI ON FAIL LED 2 1 LED LED REV:1.02 DESIGNED IN USA P1 DIMM C1 B1 A1 D1 E1 F1 C1 B1 A1 CPU2 CPU1 P1 DIMM P2 DIMM CPU1 P2_NVME0 JSXB1_3 X11DDW-L JTPM1 BAR CODE P1_NVME0 CPU2_PORT2A MAC CODE JP2 CPU2_PORT2B BIOS LICENSE LEDM1 P1_NVME1 CPU2_PORT2C SRW1 JVRM1JVRM2 CPU1_PORT3C CPU1_PORT3B JSTBY1 USB4/5(3.0) CPU1_PORT3D CPU1_PORT3A S-SGPIO2 10G PHY C620 JNVI2C1 CPU1_PORT3C CPU1_PORT3B CPU2_PORT3 SXB2:CPU2 PCI-E 3.0 X16 LE3 BT1 P2_NVME1 D1 E1 F1 CPU2 P2 DIMM CPU1_PORT3A SXB1B:CPU1 PCI-E 3.0 X16 + CPU2 PCI-E 3.0 X16 JSXB1_2 CPU1+CPU2 PCI-E 3.0 X16 JSXB1_3 JRK1 JNVI2C2 LAN2 CPU1_PORT3D P1_NVME1 (-NT) JRK1 USB2/3 (3.0) JM2_1 LE3 I-SATA4~7 I-SATA0~3 S-SATA0~3 JNVI2C2 T-SGPIO1 SRW1 JL1 VGA JPME2 JPME1 JM2_1 CPU2 PCI-E 3.0 X16 JL1 JP3 JNVI2C2 A JSXB1_1 JSXB1_1 VGA JP3 JPI2C1 FAN4 FAN3 CPU1 P2_NVME0 (-NT) Figure 1-4. Motherboard Layout 13 JF1 LE2 JP2 JSDCARD1 P1_NVME0 (-NT) BT1 JPI2C1 JPWR3 JPWR1 JPWR2 P2_NVME1 (-NT) FAN5 CPU2 USB4/5 JBT1 LEDM1 JVRM1 JVRM2 JTPM1 JD1 JBMC DEBUG JPWR1 FAN6 FAN4 FAN3 FAN5 JWD1 S-SATA4 JSTBY1 JPWR3 FAN6 S-SATA5 JIPMB1 JPG1 JPL1 FAN2 FAN1 FAN2 FAN1 JPWR2 SuperServer 6019P-WT/WTR User's Manual Quick Reference Table Jumper Description Default Setting JBT1 Clear CMOS Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN1/LAN2 Enable/Disable Pins 1-2 (Enabled) JPME1 ME Recovery Pins 1-2 (Normal) JPME2 Manufacturing (ME) Mode Select Pins 1-2 (Normal) JVRM1 VRM SMB Clock (to BMC or PCH) Pins 1-2 (BMC, Normal) JVRM2 VRM SMB Data (to BMC or PCH) Pins 1-2 (BMC, Normal) JWD1 Watch Dog Timer Pins 1-2 (Normal) Connector Description Battery (BT1) Onboard CMOS battery FAN1~6 System cooling fan headers IPMI_LAN Dedicated IPMI LAN port JAOM PCI-E 3.0 x16 SAS3 AOM controller slot JD1 Power LED/Speaker header (Pins 1-3: power LED, Pins 4-7: speaker) JF1 Front control panel header JIPMB1 4-pin external BMC I2C header (for an IPMI card) JL1 Chassis intrusion header JM2_1 M.2 slot supported by PCH JNVI C1/JNVI C2 NVMe I2C headers JPI2C1 Power Supply SMBbus I2C header JPWR1/JPWR2 12V 8-pin power supply connectors JPWR3 24-pin ATX main power supply connector JRK1 RAID Key for onboard SATA devices JSDCARD1 Micro SD Card slot JSTBY1 Standby power header JTPM1 Trusted Platform Module (TPM)/Port 80 connector JUIDB1 Unit Identifier (UID) switch LAN1/LAN2 Gigabit LAN (GLAN) Ethernet ports on the back panel P1_NVME0/P1_NVME1 (-NT) NVM Express PCI-E 3.0 x4 ports (from CPU1) P2_NVME0/P2_NVME1 (-NT) NVM Express PCI-E 3.0 x4 ports (from CPU2) (I-)SATA0~3, 4~7 I- SATA 3.0 connectors supported by the Intel PCH (S-)SATA0~3 S-SATA 3.0 connectors supported by the Intel SCU (S-)SATA4/S-SATA5 S-SATA connectors with built-in power pins and support of Supermicro SuperDOM (Disk-on Module) devices SXB1 PCI-E 3.0 (x16 + x16) Left Riser Card slot supported by CPU1 and CPU2 2 2 14 Chapter 1: Introduction Connector Description SXB2 PCI-E 3.0 x16 Right Riser Card slot supported by CPU2 T-SGPIO3 Serial General Purpose I/O port USB0/1 Back panel USB 3.0 ports USB2/3 Back panel USB 3.0 ports USB4/5 USB 3.0 headers VGA Back panel VGA port LED Description Status LE1 UID (Unit Identifier) LED Solid Blue: Unit Identified LE2 Onboard Power LED On: Onboard Power On LE3 M.2 LED Blinking Green: Device Working LEDM1 BMC Heartbeat LED Blinking Green: BMC Normal 15 SuperServer 6019P-WT/WTR User's Manual P0 P1 PECI : 30 SOCKET ID : 0 P2 #2 #1A #1B DMI3 UPI UPI SNB CORE P0 DDR-IV P2 #1A #1B PCI-E X16 G3 (LANE REVERSE) PCI-E X4 + X4 G3 PCI-E X16 G3 (LANE REVERSE) BIOS SPI BMC AST2500 SATA USB 2.0 USB iPass 4x3 SuperDOM x2 #13 #12 #11 #10 X8 UPLINK NO QAT (~15W) X8 UPLINK NO QAT (~17W) PCI-E X1 G2 USB 2.0 #5 #12 USB 3.0 USB2.0 ESPI Rear x4 Header x2 USB BMC Boot Flash 6.0 Gb/S LUIO 2 x NVME #9 #8 #7 #6 #5 #4 #3 #2 #1 #0 INTEL PCH RUIO NA PCI-E X4 + X4 G3 RTL8211E-VB-CG DDR4 (LANE REVERSE) PCI-E X8 G3 KR/KX RMII/NCSI RGRMII LAN3 RJ45 PECI : 31 SOCKET ID : 1 #2 #3 DMI3 (LANE REVERSE) LAN 10G/1G X557-AT2/88E1512 RJ45 10G/1G VCCP1 P1 DMI3 RJ45 10G/1G #M-0 #L-0 #K-0 #J-0 #H-0 #G-0 SATA DDRIV 2133/2666 UPI 10.4/11.2G PCI-E X8 G3 2 x NVME VR13 5+1 PHASE 145W VCCP0-(F) #3 PCI-E X16 G3 JAOM VCCP1 12v VR13 5+1 PHASE 145W SNB CORE DDR-IV PCI-E X16 G3 LUIO VCCP0 12v DDRIV 2133/2666 #F-0 #E-0 #D-0 #C-0 #B-0 #A-0 SPI (OPTION) ESPI Header * TBD SPI TPM HEADER Debug Card VGA CONN BIOS SYSTEM POWER Temp Sensor EMC1402-1 *2 at diff SMBUS Note: 4 x NVME (2+2) FRONT PANEL FAN SPEED CTRL ports available on the (-NT) model only. Figure 1-5. Intel C621 Chipset: System Block Diagram Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the System Specifications appendix for the actual specifications of your motherboard. 16 Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components. Caution: Electrostatic Discharge (ESD) can damage electronic components. To prevent such damage to PCBs (printed circuit boards), it is important to use a grounded wrist strap, handle all PCBs by their edges and keep them in anti-static bags when not in use. 2.2 Preparing for Setup The box in which the system was shipped should include the rackmount hardware needed to install it into the rack. Please read this section in its entirety before you begin the installation. Choosing a Setup Location • The system should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. • Leave enough clearance in front of the rack so that you can open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow sufficient space for airflow and access when servicing. • This product should be installed only in a Restricted Access Location (dedicated equipment rooms, service closets, etc.). • This product is not suitable for use with visual display workplace devices acccording to §2 of the German Ordinance for Work with Visual Display Units. Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them. 17 SuperServer 6019P-WT/WTR User's Manual • In single rack installations, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from the rack. • You should extend only one server or component at a time - extending two or more simultaneously may cause the rack to become unstable. Server Precautions • Review the electrical and general safety precautions in Appendix B. • Determine the placement of each component in the rack before you install the rails. • Install the heaviest server components at the bottom of the rack first and then work your way up. • Use a regulating uninterruptible power supply (UPS) to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure. • Allow any drives and power supply modules to cool before touching them. • When not servicing, always keep the front door of the rack and all covers/panels on the servers closed to maintain proper cooling. Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the room's ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (TMRA). Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading. 18 Chapter 2: Server Installation Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Ground A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is the only unit in the rack. • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. 19 SuperServer 6019P-WT/WTR User's Manual 2.3 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided. You should also refer to the installation instructions that came with the specific rack you are using. Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit. Each assembly consists of an outer fixed rack rail that secures directly to the rack itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of the outer rails are also included. Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. Secure the short bracket to the front side of the outer rail with two screws and the long bracket to the rear side of the outer rail with three screws. Repeat these steps for the left outer rail. Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. Warning: do not pick up the server with the front handles. They are designed to pull the system from a rack only. Warning: Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over. 20 Chapter 2: Server Installation Figure 2-1. Installing the Rails Note: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. 2.4 Installing the Server into a Rack Installing to a Standard Rack You should now have rails attached to both the chassis and the rack. The next step is to install the server into the rack. 1. Line up the rear of the chassis rails with the front of the rack rails. 2. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to press the locking tabs when inserting). See Figure 2-3. 3. When the server has been pushed completely into the rack, you should hear the locking tabs "click". Installing to a Telco Rack To install the SuperServer 6019P-WT/WTR into a Telco (or “open”) type rack, use two L-shaped brackets on either side of the chassis (four total). 1. First, determine how far the server will extend out from the front of the rack. The chassis should be positioned so that the weight is balanced between front and back. 21 SuperServer 6019P-WT/WTR User's Manual 2. Attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. 3. Finish by sliding the chassis into the rack and tightening the brackets to the rack. See Figure 2-4. Figure 2-2. Installing the Server into a Rack Note: Figure is for illustrative purposes only. Always install servers to the bottom of a rack first. Slide rail mounted equipment is not to be used as a shelf or a work space. 22 Chapter 2: Server Installation Figure 2-3. Installing the Server into a Telco Rack Note: Figure is for illustrative purposes only. Always install servers to the bottom of a rack first. 23 SuperServer 6019P-WT/WTR User's Manual Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system. Please follow the procedures given in each section. 3.1 Removing Power Use the following procedure to ensure that power has been removed from the system. This step is necessary when removing or installing non hot-swap components. 1. Use the operating system to power down the system. 2. After the system has completely shut-down, disconnect the AC power cords from the power strip or outlet. (If your system has more than one power supply, remove the AC power cords from all power supply modules.) 3. Disconnect the power cord(s) from the power supply modules. 3.2 Accessing the System The SC815TQC-605WB/R706WB features a removable top cover, which allows easy access to the inside of the chassis. Removing the Top Cover 1. Begin by removing power from the system as described in Section 3.1. 2. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). 3. Depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. 4. Lift the top cover from the chassis to gain full access to the inside of the server. Warning: Except for short periods of time, do not operate the server without the cover in place. The chassis cover must be in place to allow for proper airflow and to prevent overheating. 24 Chapter 3: Maintenance and Component Installation 3.3 Motherboard Components Processor and Heatsink Installation Follow the procedures in this section to install a processor (CPU) and heatsink to the motherboard. Notes: • The motherboard should be installed into the chassis first and the processor should be installed into the CPU socket before you install a CPU heatsink. • If you bought a CPU separately, make sure that you use an Intel-certified multi-directional heatsink only. • When receiving a motherboard without a processor pre-installed, make sure that the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Removing the Dust Cover from the CPU Socket Remove the dust cover from the CPU socket to expose the socket and socket pins as shown in the illustration below. Note: Do not touch the socket pins to avoid damage to them and to prevent the CPU from malfunctioning. Remove the dust cover from the CPU socket. Do not touch the socket pins! Socket Pins Figure 3-1. Removing the Processor Dust Cover 25 SuperServer 6019P-WT/WTR User's Manual Processor Package Assembly To properly install the CPU into the narrow processor clip, please follow the steps below. 1. Locate pin 1 (notch A), which is the triangle located on the top of the narrow processor clip. Also locate notch B and notch C on the processor clip. 2. Locate pin 1 (notch A), which is the triangle on the substrate of the CPU. Also, locate notch B and notch C on the CPU as shown below. 3. Align pin 1 (the triangle on the substrate) of the CPU with pin 1 (the triangle) of the narrow processor clip. Once they are aligned, carefully insert the CPU into the processor clip by sliding notch B of the CPU into notch B of the processor clip, and sliding notch C of the CPU into notch C of the processor clip. 4. Examine all corners of the CPU to ensure that it is properly seated on the processor clip. Once the CPU is securely attached to the processor clip, the processor package assembly is created. Note: Please exercise extreme caution when handling the CPU. Do not touch the CPU LGA-lands to avoid damaging the LGA-lands or the CPU. Be sure to wear ESD gloves when handling components. C CPU (Upside Down) w/CPU LGA Lands up Align Notch C of the CPU and Notch C of the Processor Clip B Allow Notch C to latch on to CPU A Pin 1 C C Align Notch B of the CPU and Notch B of the Processor Clip CPU/Heatsink Package (Upside Down) B B Align CPU Pin 1 Allow Notch B to latch on to CPU A A Processor Package Carrier (w/CPU mounted on the Processor Clip) Figure 3-2. Processor Package Assembly 26 Chapter 3: Maintenance and Component Installation Processor Heatsink Module (PHM) After you have made a processor package assembly by following the instructions on the previous page, please follow the steps below to mount the processor package assembly onto the heatsink to create the Processor Heatsink Module (PHM). 1. Locate "1" on the heatsink label and the triangular corner next to it on the heatsink. With your index finger pressing against the screw at this triangular corner, carefully hold and turn the heatsink upside down with the thermal-grease side facing up. Remove the protective thermal film if present, and apply the proper amount of the thermal grease as needed. (Skip this step if you have a new heatsink because the necessary thermal grease is pre-applied in the factory.) 2. Holding the processor package assembly at the center edge, turn it upside down. With the thermal-grease side facing up, locate the hollow triangle located at the corner of the processor carrier assembly ("a" in the graphic). Note a larger hole and plastic mounting clicks located next to the hollow triangle. Also locate another set of mounting clicks and a larger hole at the diagonal corner of the same (reverse) side of the processor carrier assembly ("b" in the graphic). 3. With the back of heatsink and the reverse side of the processor package assembly facing up, align the triangular corner on the heatsink ("A" in the graphic) against the mounting clips next to the hollow triangle ("a") on the processor package assembly. 4. Also align the triangular corner ("B") at the diagonal side of the heatsink with the corresponding clips on the processor package assembly ("b"). 5. Once the mounting clips on the processor package assembly are properly aligned with the corresponding holes on the back of heatsink, securely attach the heatsink to the processor package assembly by snapping the mounting clips at the proper places on the heatsink to create the processor heatsink module (PHM). 27 SuperServer 6019P-WT/WTR User's Manual Non-Fabric CPU and Processor Clip (Upside Down) Triangle on the CPU b d B a c C D Triangle on the Processor Clip Heatsink A (Upside Down) At locations C and D, the notches snap onto the heat sink’s mounting holes B C D A At locations A and B, the notches Make sure the mounting snap onto the heatsink’s sides notches snap into place Figure 3-3. Processor Heatsink Module (PHM) Removing the Processor Heatsink Module (PHM) Before removing the processor heatsink module (PHM), unplug power cord from the power outlet. 1. Using a T30 Torx-bit screwdriver, turn the screws on the PHM counterclockwise to loosen them from the socket, starting with screw marked #4 (in the sequence of 4, 3, 2, 1). 2. After all four screws are removed, wiggle the PHM gently and pull it up to remove it from the socket. Note: To properly remove the processor heatsink module, be sure to loosen and remove the screws on the PHM in the sequence of 4, 3, 2, 1 as shown below. Wait for the heatsink to cool down before removing it. 28 Chapter 3: Maintenance and Component Installation Removing the screws in the sequence of 4, 3, 2, 1 #4 #2 #1 #3 CPU Socket Printed Triangle on Motherboard After removing the screws, lift the Processor Heatsink Module off the CPU socket. Figure 3-4. Removing the PHM Memory Support The X11DDW-L supports up to 1.5 TB of ECC DDR4-2666 RDIMM (Registered DIMM) or LRDIMM (Load-Reduced DIMM) memory in 12 slots. Populating these DIMM modules with a pair of memory modules of the same type and size will result in interleaved memory, which will improve memory performance. Notes: 1. Use the memory modules of the same type and speed. Mixing memory modules of different types and speeds is not allowed. 2. When installing memory modules, be sure to install the first DIMM module in the blue memory slot, which is the first slot of a memory channel, and then install the second DIMM in the black slot if 2DPC memory configuration is used. 3. Using unbalanced memory topology by populating two DIMMs in one channel while populating one DIMM in another channel will result in reduced memory performance. 29 SuperServer 6019P-WT/WTR User's Manual DDR4 Memory Support for the Intel Xeon Scalable Processor Type Ranks Per DIMM and Data Width Speed (MT/s); Voltage (V); Slots per Channel (SPC) and DIMMs per Channel (DPC) DIMM Capacity (GB) 2 Slots per Channel 1DPC (1-DIMM per Channel) 2DPC (2-DIMM per Channel) 4 Gb 8 Gb 1.2 V 1.2 V RDIMM SRx4 8 GB 16 GB 2666 2666 RDIMM SRx8 4 GB 8 GB 2666 2666 RDIMM DRx8 8 GB 16 GB 2666 2666 RDIMM DRx4 16 GB 32 GB 2666 2666 QRX4 N/A 2H-64GB 2666 2666 8RX4 N/A 4H-128GB 2666 2666 RDIMM 3Ds LRDIMM LRDIMM 3Ds QRx4 32 GB 64 GB 2666 2666 QRX4 N/A 2H-64GB 2666 2666 8Rx4 N/A 4H-128 GB 2666 2666 DDR4 Memory Support for the Intel Xeon Scalable Processor Speed (MT/s); Voltage (V); Slots per Channel (SPC) and DIMMs per Channel (DPC) Type Ranks Per DIMM and Data Width 4 Gb 8 Gb 1.2 V RDIMM SRx4 8 GB 16 GB 2666 RDIMM SRx8 4 GB 8 GB 2666 RDIMM DRx8 8 GB 16 GB 2666 RDIMM DRx4 16 GB 32 GB 2666 QRX4 N/A 2H-64GB 2666 8RX4 N/A 4H-128GB 2666 QRx4 32 GB 64 GB 2666 QRX4 N/A 2H-64GB 2666 8Rx4 N/A 4H-128 GB 2666 RDIMM 3Ds LRDIMM LRDIMM 3Ds DIMM Capacity (GB) 1 Slot per Channel 1DPC (1-DIMM per Channel) DIMM Population Requirements For optimal memory performance, follow the tables below when populating memory modules. Key Parameters for DIMM Configurations Parameters Possible Values Number of Channels 1, 2, 3, 4, 5, or 6 Number of DIMMs per Channel 1DPC (1 DIMM Per Channel) DIMM Type RDIMM (w/ECC), LRDIMM, 3DS-LRDIMM • non-3DS RDIMM Raw Cards: A/B (2RX4), C (1RX4), DIMM Construction D (1RX8), E (2RX8) • 3DS RDIMM Raw Cards: A/B (4RX4) • non-3DS LRDIMM Raw Cards: D/E (4RX4) • 3DS LRDIMM Raw Cards: A/B (8RX4) 30 Chapter 3: Maintenance and Component Installation General Population Requirements DIMM Mixing Rules • All DIMMs must be DDR4 DIMMs only. • X4 and X8 DIMMs can be mixed in the same channel. • Mixing of LRDIMMs and RDIMMs is not allowed in the same channel, across different channels, and across different sockets. • Mixing of non-3DS and 3DS LRDIMM is not allowed in the same channel, across different channels, and across different sockets. Mixing of DIMM Types within a Channel DIMM Types RDIMM LRDIMM 3DS LRDIMM RDIMM Allowed Not Allowed Not Allowed LRDIMM Not Allowed Allowed Not Allowed 3DS LRDIMM Not Allowed NotAllowed Allowed DDR4 Only Socket Level Population Requirements DDR4 Socket Level Minimum Population Requirements • There should be at least one DDR4 DIMM per socket. • If only one DIMM is populated in a channel, then populate it in the slot furthest away from CPU. • Always populate DIMMs with a higher electrical loading in DIMM0 followed by DIMM1. DDR4 Only Memory Populations with Possible Mixes DDR4 RDIMM Within IMC DIMM Population DIMM0/DIMM1 Config. Set A DIMM0/DIMM1 Config. Set B DIMM0/DIMM1 Config. Set C Possible Mixes DIMM0/DIMM1 Single Rank, None Single Rank, Single Rank Dual Rank, Single Rank, Dual Rank, None Dual Rank, Dual Rank, Single Rank, Single Rank DDR0 x8, None, x8, x8 x4, None, x4, x4 x8, x4, or x4, x8 DDR1 None or same as DDR0 None or same as DDR0 None or same as DDR0 DDR2 None or same as DDR1 (excludes DIMM 1 in 5DIMM configurations) None or same as DDR1 (excludes DIMM 1 in 5DIMM configurations) None or same as DDR1 (excludes DIMM 1 in 5DIMM configurations) DDR4 Only Memory Populations with Possible Mixes 3DS LRDIMM or 3DS RDIMM Within IMC DIMM Population DIMM0/DIMM1 Config. Set A Possible Mixes DIMM0/DIMM1 DDR0 x4, None, x4, x4 DDR1 None or same as DDR0 Quad Rank, None Quad Rank, Quad Rank Cannot mix 3DS LRDIMM and RDIMM DDR2 None or same as DDR1 DDR4 Only Memory Populations with Possible Mixes LRDIMMs Within IMC DIMM Population DIMM0/DIMM1 DDR0 x4, None, x4, x4 DDR1 None or same as DDR0 DDR2 None or same as DDR1 31 Possible Mixes DIMM0/DIMM1 Quad Rank, None Quad Rank, Quad Rank Note: Requirements *Match DIMM types installed across DDR channels within an IMC *Always populate iMC0 first SuperServer 6019P-WT/WTR User's Manual DDR4 Only 2SPC Memory Configuration with x8 DIMMs DIMM Population within an IMC (Note: Uniformly populate with x8 DRAMs DIMMs) Total # of DIMMs DDR Channel Number of Ranks Virtual Lock Step 1 x8 DIMM Must be installed on iMC0 DDR Channel 0 1 N/A >1 SVLS 2 x8 DIMMs DDR0: Populate with 1 DIMM DDR1: Populate identically as DDR0 3 x8 DIMMs DIMM Population within an IMC (Note: Non-equal in rank pair of x8 DIMMs) DDR0: Populate with 1 DIMM DDR1: Populate identically as DDR0 DDR2: Populate identically as DDR1 1 N/A >1 SVLS 1 N/A >1 SVLS 4 x8 DIMMs DDR0: Populate with 2 DIMMs DDR1: Populate identically as DDR0 x SVLS 5 x8 DIMMs DDR Channel 0, 1, 2: DIMM0 is populated with identical DIMMs, DDR Channel 0, 1: DIMM1 is populated with identical DIMMs >1 SVLS 6 x8 DIMMs Populate 2 DIMMs per DDR channel x SVLS 1 pair of DIMMs DDR0: Populate with 1 DIMM DDR1: Populate the second DIMM (for best performance) 1 N/A >1 SVLS 2 pairs of DIMMs DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate identically as DDR0 1 N/A >1 SVLS 3 pairs of DIMMs DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate identically as DDR0 DDR2: Populate identically as DDR1 x SVLS 2 pairs+1 (5DIMMs) DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate with identical DIMMs as DDR0 DDR2: DIMM0 is populated with identical DIMM as DDR1 >1 SVLS DDR4 Only 2SPC Memory Configuration with x4 DIMMs DIMM Population within an IMC Note: Uniformly populate with x4 DRAMs/DIMMs Total # of DIMMs DDR Channel Number of Ranks Adaptive Virtual Lock Step 1 x4 DIMM Must be installed on iMC0 DDR Channel 0 1 Y, only Bank VLS 2 x4 DIMMs DDR0: Populate with 1 DIMM DDR1: Populate identically as DDR0 3 x4 DIMMs DIMM Population within an IMC Note: Nonequal in rank pair of x4 DIMMs) DDR0: Populate with 1 DIMM DDR1: Populate identically as DDR0 DDR2: Populate identically as DDR1 >1 Y 1 Y, only Bank VLS >1 Y 1 Y, only Bank VLS >1 Y 4 x4 DIMMs DDR0: Populate with 2 DIMMs DDR1: Populate identically as DDR0 x Y 5 x4 DIMMs DDR Channel 0, 1, 2: DIMM0 is populated with identical DIMMs, DDR Channel 0, 1: DIMM1 is populated with identical DIMMs >1 Y 6 x4 DIMMs Populate 2 DIMMs per DDR channel x Y 1 pair of DIMMs DDR0: Populate with 1 DIMM DDR1: Populate the second DIMM (for best performance) >1 Y 2 pairs of DIMMs DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate identically as DDR0 >1 Y 3 pairs of DIMMs DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate identically as DDR0 DDR2: Populate identically as DDR1 x Y 2 pairs+1 (5DIMMs) DDR0: Populate with 1 pair of non-equal rank DIMMs DDR1: Populate with identical DIMMs as DDR0 DDR2: DIMM0 is populated with identical DIMM as DDR1 >1 Y 32 Chapter 3: Maintenance and Component Installation DDR4 Only 2SPC Memory Configuration with x8/x4 DIMMs Mixed DDR4 RDIMM Total # of DIMMs DDR Channel ADDC/SDDC Features DIMM Population within an IMC 1 pair of x8, x4 DDR0: Populate with 1 DIMM DDR1: Populate the second DIMM (for best performance) No 2 pairs of x8, x4 Populate with 1 pair of DIMMs on DDR0, and identical pair on DDR1 No 3 pairs of x8, x4 A pair of DIMMs on DDR0, and identical pair on DDR1, and DDR2 No DIMM Installation 1. Insert DIMM modules in the following order: For CPU1, begin with P1-DIMMA1, P1DIMMB1, P1-DIMMC1 then P1-DIMMD1, P1-DIMME1, P1-DIMMF1. For CPU2, begin with P2-DIMMA1, P2-DIMMB1, P2-DIMMC1 then P2-DIMMD1, P2-DIMME1, P2DIMMF1. For the system to work properly, please use memory modules of the same type and speed on the motherboard. 2. Push the release tabs outwards on both ends of the DIMM slot to unlock it. 3. Align the key of the DIMM module with the receptive point on the memory slot. 4. Align the notches on both ends of the module against the receptive points on the ends of the slot. 5. Use two thumbs together to press the notches on both ends of the module straight down into the slot until the module snaps into place. 6. Press the release tabs to the lock positions to secure the DIMM module into the slot. DIMM Removal Reverse the steps above to remove the DIMM modules from the motherboard. Press both notches straight down into the memory slot. Notches Release Tabs Figure 3-5. Installing DIMMs 33 SuperServer 6019P-WT/WTR User's Manual PCI Expansion Card Installation The system includes two pre-installed riser cards: RSC-R1UW-E8R, for a standard size PCI-E x8 card, and RSC-R1UW-2E16, which supports two standard size PCI-E x16 cards. Risers position the expansion cards at a 90 degree angle, allowing them to fit inside the 1U chassis. Installing PCI Expansion Cards The riser card has already been pre-installed into the motherboard. Perform the following steps to install an add-on card: Begin by removing power from the system as described in section 3.1. 1. Remove the chassis cover to access the inside of the system. 2. Remove the PCI slot shield on the chassis by releasing the locking tab. 3. Insert the expansion (add-on) card into the riser card. 4. Secure the card with the locking tab. Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in section 3.1. 1. Push aside the small clamp that covers the edge of the battery. When the battery is released, lift it out of the holder. 2. To insert a new battery, slide one edge under the lip of the holder with the positive (+) side facing up. Then push the other side down until the clamp snaps over it. Note: Handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly. OR Figure 3-6. Installing the Onboard Battery Warning: There is a danger of explosion if the onboard battery is installed upside down (which reverses its polarities). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). 34 Chapter 3: Maintenance and Component Installation 3.4 Chassis Components Front Bezel If your system has an optional bezel attached to the front of the chassis, you will need to remove it to gain access to the drive bays. 1. Unlock the front of the chassis and then press the release knob. 2. Carefully remove the bezel with both hands. A filter located within the bezel can be removed for replacement/cleaning. It is recommended that you keep a maintenance log to list filter cleaning/replacement dates, since its condition affects the airflow throughout the whole system. Hard Drives Your server may or may not have come with hard drives installed. Up to four 3.5" hard drives are supported by the chassis. SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. (Both procedures may be done without removing power from the system.) Removing a Hot-Swap Drive Carrier 1. Push the release button on the carrier. 2. Swing the handle fully out. 3. Grasp the handle and use it to pull the drive carrier out of its bay. Figure 3-7. Removing a Drive Carrier 35 SuperServer 6019P-WT/WTR User's Manual Mounting a Drive in a Drive Carrier 1. To add a new drive, install it into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier. 2. Secure the drive to the carrier with the screws provided, then push the carrier completely into the drive bay. You should hear a *click* when the drive is fully inserted. This indicates that the carrier has been fully seated and connected to the midplane, which automatically makes the power and logic connections to the hard drive. Removing a Drive from a Drive Carrier 1. Remove the screws that secure the hard drive to the carrier and separate the hard drive from the carrier. 2. Replace the carrier back into the drive bay. Figure 3-8. Mounting a Drive in a Carrier Hard Drive Carrier Indicators Each hard drive carrier has two LED indicators: an activity indicator and a status indicator. In RAID configurations, the status indicator lights to indicate the status of the drive. In non-RAID configurations, the status indicator remains off. See the table below for details. Hard Drive Carrier LED Indicators LED State/Condition Indication Green Blinking Drive activity Red Blinking Drive rebuilding Red Solid on Drive failure Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www. supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf 36 Chapter 3: Maintenance and Component Installation DVD-ROM Drive Installation The 6019P-WT/WTR can accommodate a slim DVD drive (optional). Side mounting brackets are needed to install the DVD drive in the chassis. Accessing a DVD-ROM Drive Begin by removing power from the system as described in Section 3.1. 1. Unplug the power and data cables from the drive. 2. Locate the locking tab at the rear of the drive. It will be on the left side of the drive when viewed from the front of the chassis. 3. Pull the tab away from the drive and push the drive unit out the front of the chassis. 4. Add a new drive by following this procedure in reverse order. You may hear the faint *click* of the locking tab when the drive is fully inserted. 5. Reconnect the data and power cables to the drive then replace the chassis cover and restore power to the system. System Cooling Four 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counterrotating action generates exceptional airflow and is effective in dampening vibration levels. The chassis provides two additional open fan housings, where an additional system fan may be added for optimal cooling. It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components. Replacing a Failed Fan Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the exact same type and model (the system can continue to run with a failed fan). 1. With the server powered on, remove the chassis cover and inspect the fans to see which one has failed. 2. Power down the server and remove the AC power cords. 3. Remove the failed fan's wiring from the fan header on the motherboard and remove the failed fan from the chassis. 4. Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans. 37 SuperServer 6019P-WT/WTR User's Manual 5. Connect the fan wires to the same fan header as the fan just removed. 6. Power up the system and check that the fan is working properly and that the LED on the control panel has turned off. Finish by replacing the chassis cover. Figure 3-9. Replacing a System Fan Note: the figure above is intended to show fan location only. The serverboard may differ from that in the 6019P-WT/WTR. 38 Chapter 3: Maintenance and Component Installation Power Supply: 6019P-WT The SuperServer 6019P-WT has a single 600W high-efficiency power supply. The power supply module has an auto-switching capability, which enables them to automatically sense and operate with a 100V - 240V input voltage. Power Supply Failure If the power supply fails, tthe system will shut down and you will need to replace the unit. Replacement units can be ordered directly from Supermicro (see contact information in the Preface).. Removing the Power Supply Begin by removing power from the system as described in Section 3.1. 1. First unplug the power cord from the power supply module. 2. To remove the failed power module, push the release tab (on the back of the power supply) to the side and then pull the module straight out. 3. The power supply wiring was designed to detach automatically when the module is pulled from the chassis. Installing a New Power Supply 1. Replace the failed power module with another power supply module (p/n PWS-605P1H). 2. Simply push the new power supply module into the power bay until you hear a click. 3. Finish by plugging the AC power cord back into the new power module and reboot the system. Power Supply: 6019P-WTR The SuperServer 6019P-WTR has a 700W redundant power supply configuration consisting of two hot-swap, high-efficiency power modules. The power supply modules have an autoswitching capability, which enables them to automatically sense and operate with a 100V - 240V input voltage. Power Supply Failure If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The Universal Information LED on the control panel will blink slowly and remain so until the failed module has been replaced. Replacement modules can be ordered directly from Supermicro (see contact information in the Preface). The power supply modules have a hot-swap capability, meaning you can replace the failed module without powering down the system. 39 SuperServer 6019P-WT/WTR User's Manual Removing the Power Supply You do not need to shut down the system to replace a power supply module. The redundant feature will keep the system up and running while you replace the failed hot-swap module. Replace with the same model, which can be ordered directly from Supermicro (see Contact Information in the Preface). 1. First unplug the power cord from the failed power supply module. 2. To remove the failed power module, push the release tab (on the back of the power supply) to the side and then pull the module straight out (see Figure 6-6). 3. The power supply wiring was designed to detach automatically when the module is pulled from the chassis. Installing a New Power Supply 1. Replace the failed power module with another PWS-706P-1R power supply module. 2. Simply push the new power supply module into the power bay until you hear a click. 3. Finish by plugging the AC power cord back into the new power module. Figure 3-10. Removing/Replacing the Power Supply 40 Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A serverboard layout indicating component locations may be found in Chapter 1. Please review the Safety Precautions in Chapter 3 before installing or removing components. 4.1 Power Connections Two power connections on the X11DDW-L must be connected to the power supply. The wiring is included with the power supply. • 24-pin Primary ATX Power (JPWR3) • 8-pin Processor Power (JPWR1/JPWR2) Main ATX Power Connector JPWR3 is the 24-pin ATX main power supply connector. This primary power supply connector meets the ATX SSI EPS 24-pin specification. You must also connect the 8-pin (JPWR1/ JPWR2) CPU power connectors to your power supply. ATX Power 24-pin Connector Pin Definitions Pin# Definition Pin# Definition 13 +3.3V 1 +3.3V 14 NC 2 +3.3V 15 Ground 3 Ground 16 PS_ON 4 +5V 17 Ground 5 Ground 18 Ground 6 +5V 19 Ground 7 Ground 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 Ground 12 +3.3V Required Connection Important: To provide adequate power to the motherboard, connect the 24-pin and the 8-pin power connectors to the power supply. Failure to do so may void the manufacturer's warranty on your power supply and motherboard. 41 SuperServer 6019P-WT/WTR User's Manual 12V 8-pin CPU Power Connectors JPWR1 and JPWR2 are the 8-pin 12V DC power input for the CPU or alternative single power source for a special enclosure when the 24-pin ATX power is not in use. Refer to the table below for pin definitions. 12V 8-pin Power Pin Definitions Pin# Definition 1-4 Ground 5-8 +12V Required Connection 4.2 Headers and Connectors Fan Headers There are six fan headers on the motherboard. These are 4-pin fan headers; pins 1-3 are backward compatible with traditional 3-pin fans. The onboard fan speeds are controlled by Thermal Management via BIOS. When using the Thermal Management setting, please use all 3-pin fans or all 4-pin fans. Fan Header Pin Definitions Pin# Definition 1 Ground (Black) 2 +12V (Red) 3 Tachometer 4 PWM Control TPM Header The JTPM1 header is used to connect a Trusted Platform Module (TPM)/Port 80, which is available from a third-party vendor. A TPM/Port 80 connector is a security device that supports encryption and authentication in hard drives. It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. See the table below for pin definitions. Trusted Platform Module/Port 80 Header Pin Definitions Pin# Definition Pin# Definition 1 +3.3V 2 SPI_CS# 3 RESET# 4 SPI_MISO 5 SPI_CLK 6 GND 7 SPI_MOSI 8 9 +3.3V Stdby 10 42 SPI_IRQ# Chapter 4: Motherboard Connections RAID Key Header A RAID Key header is located at JRK1 on the motherboard. The RAID key is used to support onboard S-SATA connections. Intel RAID Key Pin Definitions Pins Definition 1 GND 2 PU 3.3V Stdby 3 GND 4 PCH RAID KEY SGPIO Header The T-SGPIO3 (Serial General Purpose Input/Output) header is used to communicate with the enclosure management chip on the back panel. SGPIO Header Pin Definitions Pin# Definition Pin# Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground Clock 8 NC 7 NC = No Connection Standby Power The Standby Power header is located at JSTBY1 on the motherboard. You must have a card with a Standby Power connector and a cable to use this feature. Refer to the table below for pin definitions. Standby Power Pin Definitions Pin# Definition 1 +5V Standby 2 Ground 3 No Connection Power SMB (I2C) Header The Power System Management Bus (I2C) connector (JPI2C1) monitors the power supply, fan, and system temperatures. Refer to the table below for pin definitions. Power SMB Header Pin Definitions Pin# Definition 1 Clock 2 Data 3 PMBUS_Alert 4 Ground 5 +3.3V 43 SuperServer 6019P-WT/WTR User's Manual Power LED/Speaker On the JD1 header, pins 1-3 are for the power LED and pins 4-7 are for the internal speaker. If you wish to use an external speaker, connect its cable to pins 1-4. Speaker Connector Pin Definitions Pin Setting Definition Pins 1-3 Power LED Pins 4-7 Speaker 4-pin BMC External I2C Header A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I2C connection on your system. Refer to the table below for pin definitions. External I2C Header Pin Definitions Pin# Definition 1 Data 2 Ground 3 Clock 4 No Connection Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to the table below for pin definitions. Chassis Intrusion Pin Definitions Pin# Definition 1 Intrusion Input 2 Ground NVMe I2C Header Connector JNVI2C1 and JNVI2C2 are a management headers for the Supermicro AOC NVMe PCI-E peripheral cards. Please connect the I2C cables to these connectors. NVMe Slots Use the four NVMe slots (P1_NVME0, P1_NVEM1, P2_NVEM0, and P2_NVME1) to attach high-speed PCI-E storage devices. These slots are available on the (-NT) model only. Micro SD Card There is one Micro SD memory card slot located at JSDCARD1 on the motherboard. 44 Chapter 4: Motherboard Connections M.2 Slot The X11DDW-L/NT has one M.2 slot located at JM2_1. M.2 was formerly known as Next Generation Form Factor (NGFF) and serves to replace mini PCI-E. M.2 allows for a variety of card sizes, increased functionality, and spatial efficiency. The M.2 socket on the motherboard supports PCI-E 3.0 x4 (32 Gb/s) SSD cards in the 2280 and 22110 form factors. I-SATA 3.0 and S-SATA 3.0 Ports The X  11DDW-L/NT has eight I-SATA 3.0 ports (I-SATA0~3, I-SATA4~7) and six S-SATA ports (S-SATA0~3, S-SATA4, S-SATA5). These SATA ports are supported by the Intel C620 chipset. S-SATA4/S-SATA5 can be used with Supermicro SuperDOMs which are yellow SATA DOM connectors with power pins built in, and do not require external power cables. Supermicro SuperDOMs are backward-compatible with regular SATA HDDs or SATA DOMs that need external power cables. SATA 3.0 Port Pin Definitions Pin# Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard. The other end connects to the control panel PCB board. 45 SuperServer 6019P-WT/WTR User's Manual 1 2 Power Button PWR Ground Reset Button Reset Ground 3.3V Power Fail OH/Fan Fail LED UID LED NIC2 Activity LED 3.3V Stby NIC1 Activity LED 3.3V Stby HDD LED 3.3V Stby 3.3V Power LED X X Ground NMI 19 20 Figure 4-1. JF1: Control Panel Pins Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (with a setting in the BIOS - see Chapter 4). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer. Refer to the table below for pin definitions. Power Button Pin Definitions (JF1) Pins Definition 1 Signal 2 Ground Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case to reset the system. Refer to the table below for pin definitions. Reset Button Pin Definitions (JF1) Pins Definition 3 Reset 4 Ground 46 Chapter 4: Motherboard Connections Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below for pin definitions. Power Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Supply Fail Fan Fail and UID LED Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer to the tables below for pin definitions. OH/Fan Fail Indicator Status OH/Fan Fail LED Pin Definitions (JF1) State Definition Pin# Definition Off Normal 7 Blue LED On Overheat 8 OH/Fan Fail LED Flashing Fan Fail NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity. Refer to the table below for pin definitions. LAN1/LAN2 LED Pin Definitions (JF1) Pin# Definition 9 NIC 2 Activity LED 11 NIC 1 Activity LED 47 SuperServer 6019P-WT/WTR User's Manual HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to pin 14 to show hard drive activity status. Refer to the table below for pin definitions. HDD LED Pin Definitions (JF1) Pins Definition 13 3.3V Stdby 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions. Power LED Pin Definitions (JF1) Pins Definition 15 3.3V 16 PWR LED NMI Button The non-maskable interrupt (NMI) button header is located on pins 19 and 20 of JF1. Refer to the table below for pin definitions. NMI Button Pin Definitions (JF1) Pins Definition 19 Control 20 Ground 48 Chapter 4: Motherboard Connections 4.3 Ports Rear I/O Ports See the figure below for the locations and descriptions of the various I/O ports on the rear of the motherboard. 2 1 4 6 3 5 8 7 9 Back Panel I/O Ports No. Description No. Description 1. VGA port 6. USB3 (USB3.0) 2. Dedicated IPMI LAN 7. LAN2 3. USB0 (USB3.0) 8. LAN1 4. USB1 (USB3.0) 9. Unit Identifier Switch 5. USB2 (USB3.0) VGA Port The onboard VGA port is located next to IPMI LAN port on the I/O back panel. Use this connection for VGA display. Unit Identifier Switch/UID LED Indicator A Unit Identifier (UID) switch and indicator (LE1) are located near theg rear I/O ports. When pressing the UID switch, the UID LED indicator will be turned on. Press the UID switch again to turn off the LED. The UID Indicator provides easy identification of a system unit that may be in need of service. Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. UID Switch Pin Definitions UID LED Pin Definitions Pin# Definition Color Status 1 Ground Blue: On Unit Identified 2 Ground 3 Button In 4 Button In 49 SuperServer 6019P-WT/WTR User's Manual Ethernet Ports Two LAN ports (LAN1/LAN2) and a dedicated IPMI LAN are located on the I/O back panel. These LAN ports are supported by the onboard AST 2500 BMC and accepts an RJ45 type cable. Refer to the LED Indicator Section for LAN LED information. LAN Ports Pin Definition Pin# Definition 1 Pin# Definition 10 sgnd 2 TD0+ 11 Act LED 3 TD0- 12 P3V3SB 13 Link 100 LED (Yellow, +3V3SB) 14 Link 1000 LED (Yellow, +3V3SB) TD1+ 4 TD1- 5 6 TD2+ 15 Ground 7 TD2- 16 Ground 8 TD3+ 17 Ground 9 TD3- 18 Ground Universal Serial Bus (USB) Ports There are two USB 2.0 ports (USB0/1) and two USB 3.0 ports (USB2/3) on the I/O back panel. There is one USB 3.0 header (USB4/5) on the motherboard to provide front access USB connection. Back Panel USB 0/1 (2.0) Pin Definitions Front Panel USB 4/5 (3.0/2.0) Pin Definitions Pin# Definition Pin# Definition Pin# Definition Pin# Definition 1 VBUS 11 IntA_P2_D+ 1 +5V 5 +5V USB_N 6 USB_N 2 IntA_P1_SSRX- 12 IntA_P2_D- 2 3 IntA_P1_SSRX+ 13 GND 3 USB_P 7 USB_P 4 GND 14 IntA_P2_SSTX+ 4 Ground 8 Ground 5 IntA_P1_SSTX- 15 IntA_P2_SSTX- 6 IntA_P1_SSTX+ 16 GND 7 GND 17 IntA_P2_SSRX+ 8 IntA_P1_D- 18 IntA_P2_SSRX- Pin# Definition Pin# Definition 9 IntA_P1_D+ 19 VBus 1 VBUS 10 Power 10 ID 2 D- 11 USB 2.0 Differential Pair 3 D+ 12 4 Ground 13 Ground of PWR Return 5 StdA_SSRX- 14 SuperSpeed Receiver 6 StdA_SSRX+ 15 Differential Pair 7 GND_DRAIN 16 Ground for Signal Return 8 StdA_SSTX- 17 SuperSpeed Transmitter 9 StdA_SSTX+ 18 Differential Pair Back Panel USB 2/3 (3.0) Pin Definitions 50 Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations. Note: On a two-pin jumper, "Closed" means the jumper is on both pins and "Open" indicates the jumper is either on only one pin or has been completely removed. Connector Pins 3 2 1 3 2 1 Jumper Setting CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1. First power down the system and unplug the power cord(s). 2. Remove the cover of the chassis to access the motherboard. 3. Remove the onboard battery from the motherboard. 4. Short the CMOS pads with a metal object such as a small screwdriver for at least four seconds. 5. Remove the screwdriver (or shorting device). 6. Replace the cover, reconnect the power cord(s) and power on the system. Notes: Clearing CMOS will also clear all passwords. Do not use the PW_ON connector to clear CMOS. JBT1 contact pads 51 SuperServer 6019P-WT/WTR User's Manual VGA Enable/Disable JPG1 allows you to enable or disable the VGA port using the onboard graphics controller. The default setting is Enabled. VGA Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled LAN1/2 Enable/Disable Change the setting of jumper JPL1 to enable or disable the LAN1 and LAN2 Ethernets ports.. The default setting is Enabled. LAN1/2 Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled Watch Dog JWD controls the Watch Dog function. Watch Dog is a monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs. Watch Dog must also be enabled in BIOS. The default setting is Reset. Note: When Watch Dog is enabled, the user needs to write their own application software to disable it. Watch Dog Jumper Settings Jumper Setting Definition Pins 1-2 Reset Pins 2-3 NMI Open Disabled 52 Chapter 4: Motherboard Connections I2C Bus for VRM Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers. See the table below for jumper settings. VRM Jumper Settings Jumper Setting Definition Pins 1-2 BMC (Normal) Pins 2-3 PCH Management Engine (ME) Recovery Use jumper JPME1 to select ME Firmware Recovery mode, which will limit resource allocation for essential system operation only in order to maintain normal power operation and management. In the single operation mode, online upgrade will be available via Recovery mode. See the table below for jumper settings. ME Recovery Mode Jumper Settings Jumper Setting Definition Pins 1-2 Normal Pins 2-3 ME Recovery Manufacturing Mode Close JPME2 to bypass SPI flash security and force the system to use the Manufacturing Mode, which will allow you to flash the system firmware from a host server to modify system settings. See the table below for jumper settings. Manufacturing Mode Select Jumper Settings Jumper Setting Definition Pins 1-2 Normal (Default) Pins 2-3 Manufacturing Mode 53 SuperServer 6019P-WT/WTR User's Manual 4.5 LED Indicators IPMI LAN LEDs A dedicated IPMI LAN, located on the back panel, has two LED indicators. The amber LED on the right of the IPMI LAN port indicates activity, while the LED on the left indicates the speed of the connection. See the table below for more information. LANIPMI 1/LAN 2 LAN Link LED Activity LED IPMI LAN IPMI LAN LEDs (X8ST3-F) Color/State Definition Link (left) Green: Solid Amber: Solid 100 Mbps 1Gbps Activity (Right) Amber: Blinking Active BMC Heartbeat LED LEDM1 is the BMC heartbeat LED. When the LED is blinking green, BMC is functioning normally. See the table below for the LED status. Onboard Power LED Indicator LED Color Definition Green: Blinking BMC Normal Onboard Power LED The Onboard Power LED is located at LE2 on the motherboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components. Refer to the table below for more information. Onboard Power LED Indicator LED Color Definition Off System Off (power cable not connected) Green System On 54 Chapter 4: Motherboard Connections Unit ID LED A rear UID LED indicator at LE1 is located near the UID switch on the back panel. This UID indicator provides easy identification of a system.unit that may need service. UID LED LED Indicator LED Color Definition Blue: On Unit Identified M.2 LED An M.2 LED is located at LE3 on the motherboard. When LE3 is blinking, M.2 functions normally. Refer to the table below for more information. M.2 LED State LED Color Definition Green: Blinking Device Working 55 SuperServer 6019P-WT/WTR User's Manual Chapter 5 Software After the hardware has been installed, you should install the Operating System (OS), configure RAID settings and install the drivers. Necessary drivers and utilities may be found at ftp://ftp. supermicro.com/driver. 5.1 OS Installation You must first configure RAID settings (if using RAID) before you install the Windows OS and the software drivers. To configure RAID settings, please refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the Windows OS for a RAID System 1. Insert Microsoft's Windows Setup DVD in the DVD drive and the system will start booting up from the DVD. 2. Insert the USB stick containing Windows drivers to a USB port on the system. Note: for older legacy OS's, please use a method to slipstream the drivers. 3. Select the partition on the drive in which to install Windows. 4. Browse the USB folder for the proper driver files. 5. Choose the RAID driver indicated in the Windows OS Setup screen, then choose the hard drive in which you want to install it. 6. Once all devices are specified, continue with the installation. 7. After the Windows OS installation is completed, the system will automatically reboot. Installing Windows to a Non-RAID System 1. Insert Microsoft's Windows OS Setup DVD in the DVD-ROM drive and the system will start booting up from the DVD. 2. Continue with the installation. The Windows OS Setup screen will display. 3. From the Windows OS Setup screen, press the key. The OS Setup will automatically load all device files and then continue with the Windows installation. 4. After the installation has completed, the system will automatically reboot. 56 Chapter 5: Software 5.2 Driver Installation The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. com. Some of these must be installed, such as the chipset driver. After accessing the FTP site, go into the CDR_Images directory and locate the ISO file for your motherboard. Download this file to create a DVD of the drivers and utilities it contains. (You may also use a utility to extract the ISO file if preferred.) After creating a DVD with the ISO files, insert the disk into the DVD drive on your system and the display shown in Figure 5-1 should appear. Another option is to go to the Supermicro website at http://www.supermicro.com/products/. Find the product page for your motherboard here, where you may download individual drivers and utilities to your hard drive or a USB flash drive ans install from there. Note: To install the Windows OS, please refer to the instructions posted on our website at http://www.supermicro.com/support/manuals/. Figure 5-1. Driver & Tool Installation Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. The bottom icon with a CD on it allows you to view the entire contents. 57 SuperServer 6019P-WT/WTR User's Manual 5.3 SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP). SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM Server), you can remotely control power on/off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI. SuperDoctor 5 Management Server monitors HTTP, FTP, and SMTP services to optimize the efficiency of your operation. Note: The default User Name and Password for SuperDoctor 5 is admin / admin. Figure 5-2. SuperDoctor 5 Interface Display Screen (Health Information) 58 Chapter 6: BIOS Chapter 6 BIOS 6.1 Introduction This chapter describes the AMIBIOS™ Setup utility for the motherboard. The BIOS is stored on a chip and can be easily upgraded using a flash program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of our website for any changes to BIOS that may not be reflected in this manual. Starting the Setup Utility To enter the BIOS Setup Utility, hit the key while the system is booting-up. (In most cases, the key is used to invoke the BIOS setup screen. There are a few cases when other keys are used, such as , , etc.) Each main BIOS menu option is described in this manual. The Main BIOS screen has two main frames. The left frame displays all the options that can be configured. “Grayed-out” options cannot be configured. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note that BIOS has default text messages built in. We retain the option to include, omit, or change any of these text messages.) Settings printed in Bold are the default values. A " " indicates a submenu. Highlighting such an item and pressing the key will open the list of settings within that submenu. The BIOS setup utility uses a key-based navigation system called hot keys. Most of these hot keys (, , , , , keys, etc.) can be used at any time during the setup navigation process. 59 SuperServer 6019P-WT/WTR User's Manual 6.2 Main Setup When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS setup screen is shown below.The following Main menu items will be displayed: System Date/System Time Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values using the keyboard. Press the key or the arrow keys to move between fields. The date must be entered in MM/DD/YYYY format. The time is entered in HH:MM:SS format. Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2015 after RTC reset. Supermicro X11DDW-L BIOS Version This item displays the version of the BIOS ROM used in the system. Build Date This item displays the date when the version of the BIOS ROM used in the system was built. 60 Chapter 6: BIOS Memory Information Total Memory This item displays the total size of memory available in the system. 61 SuperServer 6019P-WT/WTR User's Manual 6.3 Advanced Setup Configurations Use the arrow keys to select Boot Setup and press to access the submenu items. Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. When this occurs, revert to the default to the manufacture default settings. Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Disabled and Enabled. Option ROM Messages Use this feature to set the display mode for the Option ROM. Select Keep Current to display the current AddOn ROM setting. Select Force BIOS to use the Option ROM display set by the system BIOS. The options are Force BIOS and Keep Current. Bootup NumLock State Use this feature to set the Power-on state for the key. The options are On and Off. 62 Chapter 6: BIOS Wait For "F1" If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled. INT19 (Interrupt 19) Trap Response Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Postponed, the ROM BIOS of the host adaptors will not capture Interrupt 19 immediately and allow the drives attached to these adaptors to function as bootable devices at bootup. The options are Immediate and Postponed. Re-try Boot If this item is enabled, the BIOS will automatically reboot the system from a specified boot device after its initial boot failure. The options are Disabled, Legacy Boot, and EFI Boot. Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable. Use a SATA optical drive as a USB drive, and USB CD/DVD drives are not supported. Disable this feature after the XHCI driver has been installed in Windows. The options are Disabled and Enabled. Port 61h Bit-4 Emulation Select Enabled to enable the emulation of Port 61h bit-4 toggling in SMM (System Management Mode). The options are Disabled and Enabled. Power Configuration Watch Dog Function If enabled, the Watch Dog Timer will allow the system to reset or generate NMI based on jumper settings when it is expired for more than five minutes. The options are Disabled and Enabled. Restore on AC Power Loss Use this feature to set the power state after a power outage. Select Stay Off for the system power to remain off after a power loss. Select Power On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last power state before a power loss. The options are Stay Off, Power On, and Last State. 63 SuperServer 6019P-WT/WTR User's Manual Power Button Function This feature controls how the system shuts down when the power button is pressed. Select 4 Seconds Override for the user to power off the system after pressing and holding the power button for 4 seconds or longer. Select Instant Off to instantly power off the system as soon as the user presses the power button. The options are Instant Off and 4 Seconds Override. Throttle on Power Fail Use this feature to decrease system power by throttling CPU frequency when one power supply has failed. The options are Disabled and Enabled. CPU Configuration Processor Configuration The following CPU information will display: • Processor BSP Revision • Processor Socket • Processor ID • Processor Frequency • Processor Max Ratio • Processor Min Ratio • Microcode Revision • L1 Cache RAM • L2 Cache RAM • L3 Cache RAM • Processor 0 Version • Processor 1 Version Hyper-Threading (ALL) (Available when supported by the CPU) Select Enable to support Intel Hyper-threading Technology to enhance CPU performance. The options are Disable and Enable. 64 Chapter 6: BIOS Execute Disable Bit (Available if supported by the OS & the CPU) Select Enabled to enable the Execute-Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack. The default is Enable. (Refer to the Intel® and Microsoft® websites for more information.) Intel Virtualization Technology Use feature to enable the Vanderpool Technology. This technology allows the system to run several operating systems simultaneously. The options are Disable and Enable. PPIN Control Select Unlock/Enable to use the Protected-Processor Inventory Number (PPIN) in the system. The options are Unlock/Disable and Unlock/EnablE Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance. The options are Disable and Enable. Adjacent Cache Prefetch (Available when supported by the CPU) The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled. The CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enable. DCU Streamer Prefetcher (Available when supported by the CPU) Select Enabled to enable the DCU (Data Cache Unit) Streamer Prefetcher which will stream and prefetch data and send it to the Level 1 data cache to improve data processing and system performance. The options are Disable and Enable. DCU IP Prefetcher (Available when supported by the CPU) Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch IP addresses to improve network connectivity and system performance. The options are Enable and Disable. LLC Prefetch If set to Enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L3 cache to improve CPU performance. The options are Disable and Enable. Extended APIC Select Enable to activate APIC (Advanced Programmable Interrupt Controller) support. The options are Disable and Enable. 65 SuperServer 6019P-WT/WTR User's Manual AES-NI Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Disable and Enable. Advanced Power Management Configuration CPU P State Control This feature allows the user to configure the following CPU power settings Speedstep (Pstates) Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core frequency to reduce power consumption and heat dissipation. The options are Disabled and Enabled. EIST PSD Funtion This feature allows the user to choose between Hardware and Software to control the processor's frequency and performance (P-state). In HW_ALL mode, the processor hardware is responsible for coordinating the P-state, and the OS is responsible for keeping the P-state request up to date on all Logical Processors. In SW_ALL mode, the OS Power Manager is responsible for coordinating the P-state, and must initiate the transition on all Logical Processors. In SW_ANY mode, the OS Power Manager is responsible for coordinating the P-state and may initiate the transition on any Logical Processors. The options are HW_ALL, SW_ALL, and SW_ANY. Turbo Mode This feature will enable dynamic control of the processor, allowing it to run above stock frequency. Hardware PM State Control Hardware P-States This setting allows the user to select between OS and hardware-controlled P-states. Selecting Native Mode allows the OS to choose a P-state. Selecting Out of Band Mode allows the hardware to autonomously choose a P-state without OS guidance. Selecting Native Mode with No Legacy Support functions as Native Mode with no support for older hardware. CPU C State Control Autonomous Core C-State Enabling this setting allows the hardware to autonomously choose to enter a C-state based on power consumption and clock speed. The options are Disable and Enable. 66 Chapter 6: BIOS CPU C6 Report Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off. The options are Disable and Enable. Enhanced Halt State (C1E) Select Enabled to use Enhanced Halt-State technology, which will significantly reduce the CPU's power consumption by reducing the CPU's clock cycle and voltage during a Halt-state. The options are Disable and Enable. Package C State Control Package C State This feature allows the user to set the limit on the C State package register. The options are C0/C1 State, C2 State, C6 (Non Retention) State, C6 (Retention) state, No Limit, and Auto. CPU T State Control Software Controlled T-States Enabling this feature allows the OS to choose a T-State. The options are Enable and Disable. Chipset Configuration Warning: Setting the wrong values in the following features may cause the system to malfunction. North Bridge This feature allows the user to configure the following North Bridge settings. UPI Configuration UPI General Configuration UPI Status The following UPI information will display: • Number of CPU • Number of IIO • Current UPI Link Speed 67 SuperServer 6019P-WT/WTR User's Manual • Current UPI Link Frequency • UPI Global MMIO Low Base / Limit • UPI Global MMIO High Base / Limit • UPI Pci-e Congfiguration Base / Size Degrade Precedence Use this feature to set degrade precedence when system settings are in conflict. Select Topology Precedence to degrade Features. Select Feature Precedence to degrade Topology. The options are Topology Precedence and Feature Precedence. Link L0p Enable Select Enable for Link L0p support. The options are Enable and Disable. Link L1 Enable Select Enable for Link L1 support. The options are Enable and Disable. IO Directory Cache (IODC) IO Directory Cache is an 8-entry cache that stores the directory state of remote IIO writes and memory lookups, and saves directory updates. Use this feature to lower cache to cache (C2C) transfer latencies. The options are Disable, Auto, Enable for Remote InvItoM Hybrid Push, InvItoM AllocFlow, Enable for Remote InvItoM Hybrid AllocNonAlloc, and Enable for Remote InvItoM and Remote WViLF. Isoc Mode Select Enabled for Isochronous support to meet QoS (Quality of Service) requirements. This feature is especially important for Virtualization Technology. The options are Enable and Disable. Memory Configuration Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage programming. The options are Enabled and Disable. Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules. The options are Auto, 1333, 1400, 1600, 1800, 1867, 2000, 2133, 2200, and 2400. Data Scrambling for NVDIMM Use this festure to enable or disable data scrambling for non-volatile DIMM (NVDIMM) memory. The options are Auto, Disable, and Enable. 68 Chapter 6: BIOS Data Scrambling for DDR4 Use this feature to enable or disable data scrambling for DDR4 memory. The options are Auto, Disable, and Enable. tCCD_L Relaxation If this feature is set to Enable, SPD (Serial Presence Detect) will override tCCD_L ("Column to Column Delay-Long", or “Command to Command Delay-Long” on the column side.) If this feature is set to Disable, tCCD_L will be enforced based on the memory frequency. The options are Enable and Disable. Enable ADR Select Enable for ADR (Automatic Diagnostic Repository) support to enhance memory performance. The options are Enable and Disable. 2X REFRESH This option allows the user to select 2X refresh mode. The options are Auto, Enabled, and Disabled. Memory Topology This feature displays DIMM population information. Memory RAS Configuration Static Virtual Lockstep Mode Select Enable to run the system's memory channels in lockstep mode to minimize memory access latency. The options are Disable and Enable. Mirror Mode This feature allows memory to be mirrored between two channels, providing 100% redundancy. The options are Disable, Mirror Mode 1LM, and Mirror Mode 2LM. UEFI ARM Mirror This options allows the system to imitate the behavior of the UEFI based Address Range Mirror with setup option. The options are Disable and Enable. Memory Rank Sparing Select Enable to enable memory-sparing support for memory ranks to improve memory performance. The options are Disable and Enable. 69 SuperServer 6019P-WT/WTR User's Manual Correctable Error Threshold Use this item to specify the threshold value for correctable memory-error logging, which sets a limit on the maximum number of events that can be logged in the memory-error log at a given time. The default setting is 10. SDDC Plus One Single Device Data Correction (SDDC) organizes data in a single bundle (x4/x8 DRAM). If any or all the bits become corrupted, corrections occur. The x4 condition is corrected on all cases. The x8 condition is corrected only if the system is in Lockstep Mode. The options are Disable and Enable. ADDDC Sparing Adaptive Double Device Data Correction (ADDDC) Sparing detects when the predetermined threshold for correctable errors is reached, copying the contents of the failing DIMM to spare memory. The failing DIMM or memory rank will then be disabled. The options are Disable and Enable. Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source). When this item is set to Enable, the IO hub will read and write back one cache line every 16K cycles, if there is no delay caused by internal processing. By using this method, roughly 64 GB of memory behind the IO hub will be scrubbed every day. The options are Disable and Enable. Patrol Scrub Interval This feature allows you to decide how many hours the system should wait before the next complete patrol scrub is performed. Use the keyboard to enter a value from 0-24. The default setting is 24. IIO Configuration EV DFX Features CPU1 Configuration IOU0 (II0 PCIe Br1) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. 70 Chapter 6: BIOS IOU1 (II0 PCIe Br2) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. IOU2 (II0 PCIe Br3) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. MCP0 (II0 PCIe Br4) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. MCP1 (II0 PCIe Br5) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. CPU1 PcieBr1D00F0 - Port 1A/PcieBr1D01F0 - Port 1B/PcieBr2D00F0 - Port 2A RSC-R1UW-2E16 SLOT2 Link Speed Use this item to select the link speed for the PCI-E port specified by the user. The options are Auto, Gen 1 (2.5 GT/s), Gen 2 (5 GT/s), and Gen 3 (8 GT/s). PCI-E Port Max Payload Size Selecting Auto for this feature will enable the motherboard to automatically detect the maximum Transaction Layer Packet (TLP) size for the connected PCI-E device, allowing for maximum I/O efficiency. Selecting 128B or 256B will designate maximum packet size of 128 or 256. Options are Auto, 128, and 256. Auto is enabled by default. CPU2 Configuration IOU0 (II0 PCIe Br1) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. IOU1 (II0 PCIe Br2) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. 71 SuperServer 6019P-WT/WTR User's Manual IOU2 (II0 PCIe Br3) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. MCP0 (II0 PCIe Br4) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. MCP1 (II0 PCIe Br5) This item configures the PCI-E port Bifuraction setting for a PCI-E port specified by the user. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, x16, and Auto. CPU2 PcieBr1D00F0 - Port 1A/PcieBr1D01F0 - Port 1B/RSC-R1UW-2E16 SLOT1/RSC-R1UW-E8R SLOT1 Link Speed Use this item to select the link speed for the PCI-E port specified by the user. The options are Auto, Gen 1 (2.5 GT/s), Gen 2 (5 GT/s), and Gen 3 (8 GT/s). PCI-E Port Max Payload Size Selecting Auto for this feature will enable the motherboard to automatically detect the maximum Transaction Layer Packet (TLP) size for the connected PCI-E device, allowing for maximum I/O efficiency. Selecting 128B or 256B will designate maximum packet size of 128 or 256. Options are Auto, 128, and 256. Auto is enabled by default. IOAT Configuration Disable TPH Transparent Hugepages is a Linux memory management system that enables communication in larger blocks (pages). Enabling this feature will increase performance. The options are No and Yes. Prioritize TPH Use this feature to enable Prioritize TPH support. The options are Enable and Disable. Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain transactions to violate the strict-ordering rules of PCI bus for a transaction to be completed prior to other transactions that have already been enqueued. The options are Disable and Enable. 72 Chapter 6: BIOS Intel® VT for Directed I/O (VT-d) Intel® VT for Directed I/O (VT-d) Select Enable to use Intel Virtualization Technology for Direct I/O VT-d support by reporting the I/O device assignments to the VMM (Virtual Machine Monitor) through the DMAR ACPI tables. This feature offers fully-protected I/O resource sharing across Intel platforms, providing greater reliability, security and availability in networking and data-sharing. The options are Disabled and Enabled. Interrupt Remapping Select Enable for Interrupt Remapping support to enhance system performance. The options are Enable and Disable. PassThrough DMA Use this feature to allow devices such as network cards to access the system memory without using a processor. Select Enable to use the Non-Isoch VT_D Engine Pass Through Direct Memory Access (DMA) support. The options are Enable and Disable. ATS Use this feature to enable Non-Isoch VT-d Engine Address Translation Services (ATS) support. ATS translates virtual addresses to physical addresses. The options are Enable and Disable. Posted Interrupt Use this feature to enable VT_D Posted Interrupt. The options are Enable and Disable. Coherency Support (Non-Isoch) Use this feature to maintain setting coherency between processors or other devices. Select Enable for the Non-Iscoh VT-d engine to pass through DMA to enhance system performance. The options are Enable and Disable. Intel® VMD Technology Intel® VMD for Volume Management Device on CPU1 VMD Config for PStack0 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. 73 SuperServer 6019P-WT/WTR User's Manual *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 1A~VMD port 1D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 1A~1D. The options are Disable and Enable. VMD Config for PStack1 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 2A~VMD port 2D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 2A~2D. The options are Disable and Enable. VMD Config for PStack2 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 3A~VMD port 3D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. 74 Chapter 6: BIOS Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 3A~3D. The options are Disable and Enable. Intel® VMD for Volume Management Device on CPU2 VMD Config for PStack0 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 1A~VMD port 1D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 1A~1D. The options are Disable and Enable. VMD Config for PStack1 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 2A~VMD port 2D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 2A~2D. The options are Disable and Enable. 75 SuperServer 6019P-WT/WTR User's Manual VMD Config for PStack2 Intel® VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack. The options are Disable and Enable. *If the item "Intel VMD for Volume Management Device" above is set to Enable, the following items will be dislayed: VMD port 3A~VMD port 3D (Available when the device is detected by the system) Select Enable to use the Intel Volume Management Device Technology for this specific root port. The options are Disable and Enable. Hot Plug Capable (Available when the device is detected by the system) Use this feature to enable hot plug support for PCIe root ports 3A~3D. The options are Disable and Enable. PCI-E Completion Timeout Disable Use this feature to enable PCI-E Completion Timeout support for electric tuning. The options are Yes, No, and Per-Port. South Bridge Legacy USB Support This feature enables support for USB 2.0 and older. The options are Enabled and Disabled. Default setting is Enabled. XHCI Hand-off When disabled, the motherboard will not support USB 3.0. Options are Enabled and Disabled. Default setting is Disabled. Port 60/64 Emulation This feature allows legacy I/O support for USB devices like mice and keyboards. The options are Enabled and disabled. Default setting is Enabled. Server ME (Management Engine) Configuration This feature displays the following system ME configuration settings. • Operational Firmware Version • Backup Firmware Version 76 Chapter 6: BIOS • Recovery Firmware Version • ME Firmware Status #1 • ME Firmware Status #2 • Current State • Error Code PCH SATA Configuration When this submenu is selected, the AMI BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the following items: SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Disable and Enable. Configure SATA as Select IDE to configure a SATA drive specified by the user as an IDE drive. Select AHCI to configure a SATA drive specified by the user as an AHCI drive. Select RAID to configure a SATA drive specified by the user as a RAID drive. The options are IDE, AHCI, and RAID. SATA HDD Unlock This feature allows the user to remove any password-protected SATA disk drives. Aggressive Link Power Management When this item is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Disabled and Enabled. *If the item above "Configure SATA as" is set to RAID, the following items will display: SATA Port 0 ~ Port 7 This item displays the information detected on the installed SATA drive on the particular SATA port. • Model number of drive and capacity • Software Preserve Support 77 SuperServer 6019P-WT/WTR User's Manual Port 0 ~ Port 7 Hot Plug Set this item to Enabled for hot-plugging support, which will allow the user to replace a SATA drive without shutting down the system. The options are Disabled and Enabled. Port 0 ~ Port 7 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to initialize the device. The options are Disabled and Enabled. Port 0 ~ Port 7 SATA Device Type Use this item to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive. PCH sSATA Configuration When this submenu is selected, the AMI BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the following items: sSATA Controller This item enables or disables the onboard sSATA controller supported by the Intel PCH chip. The options are Disable and Enable. Configure sSATA as Select AHCI to configure an sSATA drive specified by the user as an AHCI drive. Select RAID to configure an sSATA drive specified by the user as a RAID drive. The options are AHCI, and RAID. SATA HDD Unlock This feature allows the user to remove any password-protected SATA disk drives. Aggressive Link Power Management When this item is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Disabled and Enabled. *If the item above "Configure SATA as" is set to RAID, the following items will display: sSATA Port 0 ~ Port 5 This item displays the information detected on the installed sSATA drive on the particular sSATA port. 78 Chapter 6: BIOS • Model number of drive and capacity • Software Preserve Support Port 0 ~ Port 5 Hot Plug Set this item to Enabled for hot-plugging support, which will allow the user to replace a SATA drive without shutting down the system. The options are Disabled and Enabled. Port 0 ~ Port 5 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to initialize the device. The options are Disabled and Enabled. Port 0 ~ Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive. PCIe/PCI/PnP Configuration The following information will display: • PCI Bus Driver Version • PCI Devices Common Settings: Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Disabled and Enabled. SR-IOV Support Use this feature to enable or disable Single Root IO Virtualization Support. The options are Disabled and Enabled. MMIO High Base Use this item to select the base memory size according to memory-address mapping for the IO hub. The options are 56 TB, 40 TB, 24 TB, 3 TB, 2 TB, and 1 TB. MMIO High Granularity Size Use this item to select the high memory size according to memory-address mapping for the IO hub. The options are 256 GB, 128 GB, 512 GB, and 1024 GB. 79 SuperServer 6019P-WT/WTR User's Manual PCI PERR/SERR Support Select Enabled to allow a PCI device to generate a PERR/SERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled. Maximum Read Request Select Auto for the system BIOS to automatically set the maximum size for a read request for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes. MMCFG Base Use this item to select the low base address for PCIE adapters to increase base memory. The options are 1G, 1.5G, 1.75G, 2G, 2.25G. and 3G. NVMe Firmware Source Use this item to select the NVMe firmware to support booting. The options are Vendor Defined Firmware and AMI Native Support. The default option, Vendor Defined Firmware, is pre-installed on the drive and may resolve errata or enable innovative functions for the drive. The other option, AMI Native Support, is offered by the BIOS with a generic method. VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot. The options are Onboard and Offboard. M.2 PCI-E 3.0 X4 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled, Legacy, and EFI. CPU1 AOM PCI-E 3.0 x16 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled, Legacy, and EFI. RSC-R1UW-2E16 SLOT1 PCI-E x16 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled, Legacy, and EFI. RSC-R1UW-2E16 SLOT2 PCI-E x16 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled, Legacy, and EFI. RSC-R1UW-E8R SLOT1 PCI-E x8 OPROM Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled, Legacy, and EFI. 80 Chapter 6: BIOS Onboard LAN Device Select Enabled to enable the Onboard LAN device. The options are Enabled and Disabled. Onboard LAN1 Option ROM Use this feature to select which firmware function to be loaded for LAN Port1 used for system boot. The options are Disabled, Legacy, and EFI. Onboard LAN2 Option ROM Use this feature to select which firmware function to be loaded for LAN Port2 used for system boot. The options are Disabled, Legacy, and EFI. Onboard Video Option ROM Use this item to select the Onboard Video Option ROM type. The options are Disabled, Legacy, and EFI. Network Stack Configuration Network Stack Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible Firmware Interface) for network stack support. The options are Enabled and Disabled. *If "Network Stack" is set to Enabled, the following items will display: Ipv4 PXE Support Use this feature to enable Ipv4 PXE Boot Support. If this feature is disabled, it will not create the Ipv4 PXE Boot option. The options are Disabled and Enabled. Ipv4 HTTP Support Use this feature to enable Ipv4 HTTP Boot Support. If this feature is disabled, it will not create the Ipv4 HTTP Boot option. The options are Disabled and Enabled. Ipv6 PXE Support Use this feature to enable Ipv6 PXE Boot Support. If this feature is disabled, it will not create the Ipv6 PXE Boot option. The options are Disabled and Enabled. Ipv6 HTTP Support Use this feature to enable Ipv6 HTTP Boot Support. If this feature is disabled, it will not create the Ipv6 HTTP Boot option. The options are Disabled and Enabled. PXE Boot Wait Time Use this feature to select the wait time to press the ESC key to abort the PXE boot. The default is 0. 81 SuperServer 6019P-WT/WTR User's Manual Media Detect Count Use this feature to select the wait time in seconds to detect LAN media. The default is 1. Super IO Configuration The following Super IO information will display: • Super IO Chip AST2500 Serial Port 1 Configuration Serial Port 1 Select Enabled to enable the onboard serial port specified by the user. The options are Enabled and Disabled. Device Settings This item displays the base I/O port address and the Interrupt Request address of a serial port specified by the user. Note: This item is hidden when Serial Port 1 is set to Disabled. Change Port 1 Settings This feature specifies the base I/O port address and the Interrupt Request address of Serial Port 1. Select Auto for the BIOS to automatically assign the base I/O and IRQ address to a serial port specified. The options for Serial Port 2 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12). Serial Port 2 Configuration Serial Port 2 Select Enabled to enable the onboard serial port specified by the user. The options are Enabled and Disabled. Device Settings This item displays the base I/O port address and the Interrupt Request address of a serial port specified by the user. Note: This item is hidden when Serial Port 2 is set to Disabled. 82 Chapter 6: BIOS Change Port 2 Settings This feature specifies the base I/O port address and the Interrupt Request address of Serial Port 2. Select Auto for the BIOS to automatically assign the base I/O and IRQ address to a serial port specified. The options for Serial Port 2 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12). Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial_Over_LAN (SOL) port for console redirectoin. The options are COM and SOL. Serial Port Console Redirection COM0 Console Redirection Select Enabled to enable console redirection support for a serial port specified by the user. The options are Enabled and Disabled. *If the item above set to Enabled, the following items will become available for user's configuration: COM2/SOL Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI. Bits per second Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second). Data Bits Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits. 83 SuperServer 6019P-WT/WTR User's Manual Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space. Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2. Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS. VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled. Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled. Resolution 100x31 Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled. Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25. Putty KeyPad This feature selects the settings for Function Keys and KeyPad used for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SC0, ESCN, and VT400. Redirection After BIOS POST Use this feature to enable or disable legacy console redirection after BIOS POST. When set to Bootloader, legacy console redirection is disabled before booting the OS. When set to Always 84 Chapter 6: BIOS Enable, legacy console redirection remains enabled when booting the OS. The options are Always Enable and Bootloader. Legacy Console Redirection Settings Legacy Serial Redirection Port Use this feature to select a COM port to display redirection of Legacy OS and Legacy OPROM messages. The options are COM1 and SOL/COM2. EMS Console Redirection Settings EMS Console Redirection This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. *If the item above set to Enabled, the following items will become available for user's configuration: Terminal Type Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VTUTF8, and ANSI. Bits Per Second This item sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 57600, and 115200 (bits per second). Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None, Hardware RTS/CTS, and Software Xon/Xoff. Data Bits Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits. 85 SuperServer 6019P-WT/WTR User's Manual Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark and Space. Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2. ACPI Settings Numa This setting Enables or Disables Non-Uniform Memory Access (NUMA), a feature that improves memory-to-processor communication and performance. The options are Enabled or Disabled. WHEA Support Select Enabled to support the Windows Hardware Error Architecture (WHEA) platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring. The options are Enabled and Disabled. High Precision Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled. 86 Chapter 6: BIOS Trusted Computing (Available when a TPM device is installed and detected by the BIOS) When a TPM (Trusted-Platform Module) device is detected in your machine, the following information will be displayed. • TPM2.0 Device Found • Vendor • Firmware Version Security Device Support If this feature and the TPM jumper (JPT1) on the motherboard are both enabled, the onboard security (TPM) device will be enabled in the BIOS to enhance data integrity and system security. Please note that the OS will not show the security device. Neither TCG EFI protocol nor INT1A interaction will be made available for use. If you have made changes on the setting on this item, be sure to reboot the system for the change to take effect. The options are Disable and Enable. If this option is set to Enable, the following screen and items will display: • Active PCR Banks • Available PCR Banks 87 SuperServer 6019P-WT/WTR User's Manual Pending Operation Use this feature to schedule a TPM-related operation to be performed by a security (TPM) device at the next system boot to enhance system data integrity. Your system will reboot to carry out a pending TPM operation. The options are None and TPM Clear. Note: Your system will reboot to carry out a pending TPM operation. Platform Hierarchy (for TPM Version 2.0 and above) Select Enabled for TPM Platform Hierarchy support which will allow the manufacturer to utilize the cryptographic algorithm to define a constant key or a fixed set of keys to be used for initial system boot. This early boot code is shipped with the platform and is included in the list of "public keys". During system boot, the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmware used in a host system via a TPM device. The options are Enabled and Disabled. Storage Hierarchy Select Enabled for TPM Storage Hierarchy support that is intended to be used for non-privacysensitive operations by the platform owner such as an IT professional or the end user. Storage Hierarchy has an owner policy and an authorization value, both of which can be set and are held constant (-rarely changed) through reboots. This hierarchy can be cleared or changed independently of the other hierarchies. The options are Enabled and Disabled. Endorsement Hierarchy Select Enabled for Endorsement Hierarchy support, which contains separate controls to address the user's privacy concerns because the primary keys in this hierarchy are certified by the TPM or a manufacturer to be constrained to an authentic TPM device that is attached to an authentic platform. A primary key can be an encrypted, and a certificate can be created using TPM2_ ActivateCredential. It allows the user to independently enable "flag, policy, and authorization value" without involving other hierarchies. A user with privacy concerns can disable the endorsement hierarchy while still using the storage hierarchy for TPM applications and permitting the platform software to use the TPM. The options are Enabled and Disabled. PH (Platform Hierarchy) Randomization (for TPM Version 2.0 and above) Select Enabled for Platform Hierarchy Randomization support, which is used only during the platform developmental stage. This feature cannot be enabled in the production platforms. The options are Disabled and Enabled. TXT Support Select Enabled to enable Intel Trusted Execution Technology (TXT) support to enhance system security and data integrity. The options are Disabled and Enabled. 88 Chapter 6: BIOS Note 1: If the option for this item (TXT Support) is set to Enabled, be sure to disable EV DFX (Device Function On-Hide) support for the system to work properly. (EV DFX is under "IIO Configuration" in the "Chipset/North Bridge" submenu). Note 2: For more information on TPM, please refer to the TPM manual at http://www. supermicro.com/manuals/other. iSCSI Configuration iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format. Once the name of the iSCSI Initiator is entered into the system, configure the proper settings for the following items. Add an Attempt Delete Attempts Change Attempt Order Intel(R) Virtual RAID on CPU Intel(R) VROC with VMD Technology 5.0.0.1205 RAID volumes and Intel VMD Controllers information will be displayed if they are detected by the system. Dynamic NVMe Device Setting This setting is dependent on the NVMe device that is plugged into the assoicated port. 89 SuperServer 6019P-WT/WTR User's Manual 6.4 Event Logs Use this feature to configure Event Log settings. Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled. Erasing Settings Erase Event Log If No is selected, data stored in the event log will not be erased. Select Yes, Next Reset, data in the event log will be erased upon next system reboot. Select Yes, Every Reset, data in the event log will be erased upon every system reboot. The options are No, Yes, Next reset, and Yes, Every reset. When Log is Full Select Erase Immediately for all messages to be automatically erased from the event log when the event log memory is full. The options are Do Nothing and Erase Immediately. 90 Chapter 6: BIOS SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled. MECI The Multiple Event Count Increment (MECI) counter counts the number of occurences that a duplicate event must happen before the MECI counter is incremented. This is a numeric value. The default value is 1. METW The Multiple Event Time Window (METW) defines number of minutes must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default value is 60. Note: After making changes on a setting, be sure to reboot the system for the changes to take effect. View SMBIOS Event Log This section displays the contents of the SMBIOS Event Log. 91 SuperServer 6019P-WT/WTR User's Manual 6.5 IPMI Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. BMC Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status (Baseboard Management Controller) This item indicates the status of the IPMI firmware installed in your system. System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup. The options are Enabled and Disabled. Erasing Settings Erase SEL Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset. 92 Chapter 6: BIOS When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately. BMC Network Configuration BMC Network Configuration Configure IPV4 support IPMI LAN Selection This item displays the IPMI LAN setting. The default setting is Failover. IPMI Network Link Status This item displays the IPMI Network Link status. The default setting is Dedicated LAN. Update IPMI LAN Configuration Select Yes for the BIOS to implement all IP/MAC address changes at the next system boot. The options are No and Yes. *If the item above set to Yes, the following item will become available for user's configuration: Configuration Address Source This feature allows the user to select the source of the IP address for this computer. If Static is selected, you will need to know the IP address of this computer and enter it to the system manually in the field. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Configuration Protocol) server in the network that is attached to and request the next available IP address for this computer. The options are DHCP and Static. Station IP Address This item displays the Station IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). Subnet Mask This item displays the sub-network that this computer belongs to. The value of each threedigit number separated by dots should not exceed 255. Station MAC Address This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit hexadecimal numbers. 93 SuperServer 6019P-WT/WTR User's Manual Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 172.31.0.1). VLAN This item displays the virtual LAN settings. Configure IPV6 Support This section displays configuration features for IPV6 support. LAN Channel 1 IPV6 Support Use this feature to enable IPV6 support. The options are Enabled and Disabled. Configuration Address Source This feature allows the user to select the source of the IP address for this computer. If Static is selected, you will need to know the IP address of this computer and enter it to the system manually in the field. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Configuration Protocol) server in the network that is attached to and request the next available IP address for this computer. The options are Unspecified, Static, and DHCP. *If the item "Configuration Address Source" above is set to Static, the following items will become available for configuration: • Station IPV6 Address • Prefix Length • IPV6 Router1 IP Address • IPV6 address status • IPV6 DHCP Algorithm 94 Chapter 6: BIOS 6.6 Security This menu allows the user to configure the following security settings for the system. Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long. User Password Use this feature to set the user password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long. Password Check Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility. The options are Setup and Always. HDD Security Configuration HDD devices that are connected to the system will show up in this section. Selecting an HDD device will allow the user to access, modify, set, and clear authentication for the selected HDD device. 95 SuperServer 6019P-WT/WTR User's Manual Secure Boot When you select this submenu and press the key, the following items will display: • System Mode • Secure Boot • Vendor Keys Secure Boot If this item is set to Enabled, Secure Boot will be activated when a Platform Key (PK) is entered. A Platform Key is a security key used to manage the security settings of the platform firmware used in your system. The options are Enabled and Disabled. Secure Boot Mode Use this feature to select the desired secure boot mode for the system. The options are Standard and Custom. CSM Support Select Enabled to support the EFI Compatibility Support Module (CSM), which provides compatibility support for traditional legacy BIOS for system boot. The options are Enabled and Disabled. Key Management This submenu allows the user to configure the following Key Management settings. Provision Factory Default Keys Select Enabled to install the default Secure-Boot keys set by the manufacturer. The options are Disabled and Enabled. Enroll All Factory Default Keys Select Yes to install all default secure keys set by the manufacturer. The options are Yes and No. Enroll EFI Image This feature allows the image to run in Secure Boot Mode. Enroll SHA256 Hash Certicate of the image into the Authorized Signature Database. Save All Secure Boot Variables This feature allows the user to decide if all secure boot variables should be saved. 96 Chapter 6: BIOS Platform Key (PK) This feature allows the user to configure the settings of the platform keys. Set New Select Yes to load the new platform keys (PK) from the manufacturer's defaults. Select No to load the platform keys from a file. The options are Yes and No. Key Exchange Keys Set New Select Yes to load the KEK from the manufacturer's defaults. Select No to load the KEK from a file. The options are Yes and No. Append Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select No to load the KEK from a file. The options are Yes and No. Authorized Signatures Set New Select Yes to load the database from the manufacturer's defaults. Select No to load the DB from a file. The options are Yes and No. Append Select Yes to add the database from the manufacturer's defaults to the existing DB. Select No to load the DB from a file. The options are Yes and No. Forbidden Signatures Set New Select Yes to load the DBX from the manufacturer's defaults. Select No to load the DBX from a file. The options are Yes and No. Append Select Yes to add the DBX from the manufacturer's defaults to the existing DBX. Select No to load the DBX from a file. The options are Yes and No. 97 SuperServer 6019P-WT/WTR User's Manual Authorized TimeStamps Set New Select Yes to load the DBT from the manufacturer's defaults. Select No to load the DBT from a file. The options are Yes and No. Append Select Yes to add the DBT from the manufacturer's defaults list to the existing DBT. Select No to load the DBT from a file. The options are Yes and No. OsRecovery Signature This item uploads and installs an OSRecovery Signature. You may insert a factory default key or load from a file. The file formats accepted are: 1) Public Key Certificate a. EFI Signature List b. EFI CERT X509 (DER Encoded) c. EFI CERT RSA2048 (bin) d. EFI SERT SHA256 (bin) 2) EFI Time Based Authenticated Variable When prompted, select "Yes" to load Factory Defaults or "No' to load from a file. Set New Select Yes to load the DBR from the manufacturer's defaults. Select No to load the DBR from a file. The options are Yes and No. Append This item uploads and adds an OSRecovery Signature into the Key Management. You may insert a factory default key or load from a file. When prompted, select "Yes" to load Factory Defaults or "No' to load from a file. 98 Chapter 6: BIOS 6.7 Boot Use this feature to configure Boot settings. Boot Mode Select Use this feature to select the type of devices that the system is going to boot from. The options are Legacy, UEFI (Unified Extensible Firmware Interface), and Dual. Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot. Press on each entry from top to bottom to select devices. When the item above -"Boot Mode Select" is set to Dual (default), the following items will be displayed for configuration: • Boot Option #1 - Boot Option #17 When the item above -"Boot Mode Select" is set to Legacy, the following items will be display for configuration: • Boot Option #1 - Boot Option #8 When the item above -"Boot Mode Select" is set to UEFI, the following items will be display for configuration: • Boot Option #1 - Boot Option #9 99 SuperServer 6019P-WT/WTR User's Manual Add New Boot Option This feature allows the user to add a new boot option to the boot priority features for your system. Add Boot Option Use this item to specify the name for the new boot option. Path for Boot Option Use this feature to enter the path for the new boot option in the format fsx:\path\filename.efi. Boot Option File Path Use this feature to specify the file path for the new boot option. Create After the name and the file path for the boot option are set, press to create the new boot option in the boot priority list. Delete Boot Option This feature allows the user to select a boot device to delete from the boot priority list. Delete Boot Option Use this item to remove an EFI boot option from the boot priority list. UEFI Application Boot Priorities This feature sets the system boot order of detected devices. • Boot Option #1 Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devices. • Boot Option #1 NETWORK Drive BBS Priorities This feature sets the system boot order of detected devices. • Boot Option #1 100 Chapter 6: BIOS 6.8 Save & Exit Select the Save & Exit tab from the BIOS setup screen to configure the settings below: Save Options Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit from the Save & Exit menu and press . Save Changes and Reset After completing the system configuration changes, select this option to save the changes you have made. This will not reset (reboot) the system. Save Changes When you have completed the system configuration changes, select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters to take effect. Select Save Changes from the Save & Exit menu and press . Discard Changes Select this option and press to discard all the changes and return to the AMI BIOS utility program. 101 SuperServer 6019P-WT/WTR User's Manual Default Options Restore Defaults To set this feature, select Restore Defaults from the Save & Exit menu and press . These are factory settings designed for maximum system stability, but not for maximum performance. Save As User Defaults To set this feature, select Save as User Defaults from the Save & Exit menu and press . This enables the user to save any changes to the BIOS setup for future use. Restore User Defaults To set this feature, select Restore User Defaults from the Save & Exit menu and press . Use this feature to retrieve user-defined settings that were saved previously. Boot Override Listed in this section are other boot options for the system (i.e., Built-in EFI shell). Select an option and press . Your system will boot to the selected boot option. 102 Appendix A: BIOS Codes Appendix A BIOS Codes A.1 BIOS Error POST (Beep) Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs. These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list (on the following page) correspond to the number of beeps for the corresponding error. All errors listed, with the exception of Beep Code 8, are fatal errors. BIOS Beep (POST) Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset (Ready to power up) 5 short, 1 long Memory error No memory detected in system 5 long, 2 short Display memory read/write error Video adapter missing or with faulty memory 1 long continuous System OH System overheat condition 103 SuperServer 6019P-WT/WTR User's Manual A.2 Additional BIOS POST Codes The AMI BIOS supplies additional checkpoint codes, which are documented online at http:// www.supermicro.com/support/manuals/ ("AMI BIOS POST Codes User's Guide"). When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/. 104 SuperServer 6019P-WT/WTR User's Manual Appendix B Standardized Warning Statements for AC Systems B.1 About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/ policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. 警告の定義 この警告サインは危険を意味します。 人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、 電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。 此警告符号代表危险。 您正处于可能受到严重伤害的工作环境中。在您使用设备开始工作之前,必须充分意识到触电 的危险,并熟练掌握防止事故发生的标准工作程序。请根据每项警告结尾的声明号码找到此设 备的安全性警告说明的翻译文本。 此警告符號代表危險。 您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸電的危險, 並且要熟悉預防事故發生的標準工作程序。請依照每一注意事項後的號碼找到相關的翻譯說明 內容。 105 Appendix B: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF. INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo. GUARDE ESTAS INSTRUCCIONES. IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS. ‫תקנון הצהרות אזהרה‬ ‫ על מנת להזהיר את המשתמש מפני חבלה‬,‫הצהרות הבאות הן אזהרות על פי תקני התעשייה‬ ‫ יש ליצור קשר עם מחלקת תמיכה‬,‫ במידה ויש שאלות או היתקלות בבעיה כלשהי‬.‫פיזית אפשרית‬ .‫ טכנאים מוסמכים בלבד רשאים להתקין או להגדיר את הרכיבים‬.‫טכנית של סופרמיקרו‬ .‫יש לקרוא את הנספח במלואו לפני התקנת או הגדרת הרכיבים במארזי סופרמיקרו‬ 106 SuperServer 6019P-WT/WTR User's Manual . ‫ا ًك ف حالة ٌويك أى تتسبب ف اصابة جسذ ٌة هذا الزهز ٌع خطز !تحذ ٌز‬ ‫يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬،‫قبل أى تعول عىل أي هعذات‬ ‫الكهزبائ ٍة‬ ‫ويك عىل درا ٌة بالووارسات الىقائ ٍة لو ٌع وقىع أي حىادث‬ ‫استخذم رقن الب اٍى الو ٌصىص ف ًها ٌة كل تحذ ٌز للعثىر تزجوتها‬ 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준 작업절차를 준수해 주시기 바랍니다. 해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를 참조하십시오 BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie. BEWAAR DEZE INSTRUCTIES Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 107 Appendix B: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש לקרוא את הוראות התקנה לפני חיבור המערכת למקור מתח‬ ‫اقر إرشادات الرتكيب قبل توصيل النظام إىل مصدر للطاقة‬ 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오. Waarschuwing Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit. Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキット・ブレーカー この製品は、短絡(過電流)保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、20 Aを超えないことを確認下さい。 警告 此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电流不大于 250V,20A。 警告 此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電流不大於 250V,20A。 108 SuperServer 6019P-WT/WTR User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio. Asegúrese de que el dispositivo de protección no sea superior a: 250 V, 20 A. Attention Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de l'installation électrique du local. Vérifiez que le courant nominal du dispositif de protection n'est pas supérieur à :250 V, 20 A. ‫ יש לוודא כי‬.‫מוצר זה מסתמך על הגנה המותקנת במבנים למניעת קצר חשמלי‬ 60VDC, 20A-‫המכשיר המגן מפני הקצר החשמלי הוא לא יותר מ‬ ‫هذا املنتج يعتمد عىل معداث الحاميت مه الدوائرالقصرية التي تم تثبيتها يف‬ ‫املبنى‬ 20A, 250V : ‫تأكد من أن تقييم الجهاز الوقايئ ليس أكرث من‬ 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V, 20A. 109 Appendix B: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、 シャーシー内部にアクセスするには、 システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り外す必要が あります。 警告 在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。 警告 在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。 Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen. ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour installer ou enlever des composants de systéme. ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬. 110 SuperServer 6019P-WT/WTR User's Manual ‫يجب فصم اننظاو من جميع مصادر انطاقت وإزانت سهك انكهرباء من وحدة امداد‬ ‫انطاقت قبم‬ ‫انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إزانت مكىناث الجهاز‬ 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결되어있는 모든 전원과 전기코드를 분리해주어야 합니다. Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、 またはサービスを許可されていま す。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden. ¡Advertencia! Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo. 111 Appendix B: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫ להחליף את הציוד או לתת שירות עבור הציוד‬,‫צוות מוסמך בלבד רשאי להתקין‬ ‫واملدربيه لتزكيب واستبدال أو خدمة هذا الجهاس يجب أن يسمح فقط للمىظفيه املؤهليه‬ 경고! 훈련을 받고 공인된 기술자만이 이 장비의 설치, 교체 또는 서비스를 수행할 수 있습니다. Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations). アクセス制限区域 このユニットは、 アクセス制限区域に設置されることを想定しています。 アクセス制限区域は、特別なツール、鍵と錠前、 その他のセキュリティの手段を用いてのみ出入りが 可能です。 警告 此部件应安装在限制进出的场所,限制进出的场所指只能通过使用特殊工具、锁和钥匙或其它 安全手段进出的场所。 警告 此裝置僅限安裝於進出管制區域,進出管制區域係指僅能以特殊工具、鎖頭及鑰匙或其他安全 方式才能進入的區域。 112 SuperServer 6019P-WT/WTR User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad. Attention Cet appareil doit être installée dans des zones d'accès réservés. L'accès à une zone d'accès réservé n'est possible qu'en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫ הגישה ניתנת בעזרת‬.‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה‬ (.‫ מנעול וכד‬,‫'כלי אבטחה בלבד )מפתח‬ . ‫تخصيص هذه انىحذة نترك بُها ف مناطق محظورة تم‬ ‫ َمكن انىصىل إن منطقت محظورة فقط من خالل استخذاو أداة خاصت‬، ‫أو أ وس هُت أخري نالألمما قفم ومفتاح‬ 경고! 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및 키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다. Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang. Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap, slot en sleutel of andere veiligheidsmaatregelen. 113 Appendix B: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い 電池交換が正しく行われなかった場合、破裂の危険性があります。交換する電池はメーカーが推 奨する型、 または同等のものを使用下さい。使用済電池は製造元の指示に従って処分して下さい。 警告 电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池。请按制造商的说明处理废旧电池。 警告 電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有電池。請按 照製造商的說明指示處理廢棄舊電池。 Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant. ¡Advertencia! Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante. !‫אזהרה‬ ‫ יש להחליף‬.‫קיימת סכנת פיצוץ של הסוללה במידה והוחלפה בדרך לא תקינה‬ .‫את הסוללה בסוג התואם מחברת יצרן מומלצת‬ .‫סילוק הסוללות המשומשות יש לבצע לפי הוראות היצרן‬ 114 SuperServer 6019P-WT/WTR User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다. 제조사의 안내에 따라 사용 된 배터리를 처리하여 주십시오. Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden. Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニットは複数の電源装置が接続されている場合があります。 ユニットの電源を切るためには、すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden. 115 Appendix B: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées. ‫אם קיים יותר מספק אחד‬ !‫אזהרה‬ ‫ יש להסיר את כל החיבורים על מנת לרוקן‬.‫ליחדה יש יותר מחיבור אחד של ספק‬ .‫את היחידה‬ . ‫قد يكون لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة‬ ‫يجب إزالة كافة االتصاالت لعسل الوحدة عن الكهرباء‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를 제거해야만 합니다. Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. 116 SuperServer 6019P-WT/WTR User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。 修理する際には注意ください。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf. Vorsicht bei der Wartung. ¡Advertencia! Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso. Tenga cuidado cuando lo revise. Attention Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de panier. Prendre des précautions lors de la maintenance. ‫מתח בפנל האחורי‬ !‫אזהרה‬ ‫ יש להיזהר במהלך‬.‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת‬ .‫העבודה‬ 117 Appendix B: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذرا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud. Comply with Local and National Electrical Codes Warning! Installation of the equipment must comply with local and national electrical codes. 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 警告 设备安装必须符合本地与本国电气法规。 警告 設備安裝必須符合本地與本國電氣法規。 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen. ¡Advertencia! La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales. Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. 118 SuperServer 6019P-WT/WTR User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften. Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要があります。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. 119 Appendix B: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص النهايئ من هذا املنتج ينبغي التعامل معه وفقا لجميع القىانني واللىائح الىطنية عند‬ 경고! 이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다. Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. Hot Swap Fan Warning Warning! Hazardous moving parts. Keep away from moving fan blades. The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing. ファン・ホットスワップの警告 警告!回転部品に注意。運転中は回転部(羽根)に触れないでください。シャーシから冷却ファン装 置を取り外した際、 ファンがまだ回転している可能性があります。ファンの開口部に、指、 ドライバ ー、およびその他のものを近づけないで下さい。 警告! 警告!危险的可移动性零件。请务必与转动的风扇叶片保持距离。 当您从机架移除风扇装置, 风扇可能仍在转动。小心不要将手指、螺丝起子和其他物品太靠近风扇 警告 危險的可移動性零件。請務必與轉動的風扇葉片保持距離。 當您從機架移除風扇裝置,風扇可 能仍在轉動。小心不要將手指、螺絲起子和其他物品太靠近風扇。 120 SuperServer 6019P-WT/WTR User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Riesgo de piezas móviles. Mantener alejado de las aspas del ventilador. Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis. Mandtenga los dedos, los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses. Se tenir a l’ecart des lames du ventilateur Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres objets soient éloignés du logement du bloc ventilateur. !‫אזהרה‬ ‫ התרחק מלהבי המאוורר בפעולהכאשר מסירים את חלקי‬.‫חלקים נעים מסוכנים‬ ‫ יש להרחיק למרחק בטוח את‬.‫ יתכן והמאווררים עדיין עובדים‬,‫המאוורר מהמארז‬ ‫האצבעות וכלי עבודה שונים מהפתחים בתוך המאוורר‬ ‫من املمكن أن‬.‫ ابتعد عن شفرات املروحة املتحركة‬.‫تحذیر! أجزاء متحركة خطرة‬ ‫املراوح ال تزال تدورعند إزالة كتلة املروحة من الھیكل یجب إبقاء األصابع‬ ‫ومفكات الرباغي وغیرھا من األشیاء بعیدا عن الفتحات يف كتلة املروحة‬. 경고! 움직이는 위험한 부품. 회전하는 송풍 날개에 접근하지 마세요. 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 않도록 배치해 주십시오. Waarschuwing Gevaarlijk bewegende onderdelen. Houd voldoende afstand tot de bewegende ventilatorbladen. Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel uit het chassis. Houd uw vingers, schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing. 121 Appendix B: Standardized Warning Statements Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター 製品を設置する場合、提供または指定および購入された接続ケーブル、電源コードとACアダプター を 該当する地域の条例や安全基準に適合するコードサイズやプラグと共に使用下さい。他のケー ブルやアダプタを使用すると故障や火災の原因になることがあります。 電気用品安全法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表記)を Supermicro が指定する製品以外に使用することを禁止しています。 警告 安装此产品时,请使用本身提供的或指定的或采购的连接线,电源线和电源适配器,包含遵照当 地法规和安全要求的合规的电源线尺寸和插头.使用其它线材或适配器可能会引起故障或火灾。 除了Supermicro所指定的产品,电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材。(线材上会显示UL/CSA符号)。 警告 安裝此產品時,請使用本身提供的或指定的或採購的連接線,電源線和電源適配器,包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭.使用其它線材或適配器可能會引起故障或火災。 除了Supermicro所指定的產品,電氣用品和材料安全法律規定禁止 使用未經UL或CSA認證的線材。 (線材上會顯示UL/CSA符號)。 Warnung Nutzen Sie beim Installieren des Produkts ausschließlich die von uns zur Verfügung gestellten Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind. 122 SuperServer 6019P-WT/WTR User's Manual ¡Advertencia! Cuando instale el producto, utilice la conexión provista o designada o procure cables, Cables de alimentación y adaptadores de CA que cumplan con los códigos locales y los requisitos de seguridad, incluyendo el tamaño adecuado del cable y el enchufe. El uso de otros cables y adaptadores podría causar un mal funcionamiento o un incendio. La Ley de Seguridad de Aparatos Eléctricos y de Materiales prohíbe El uso de cables certificados por UL o CSA (que tienen el certificado UL / CSA en el código) para cualquier otros dispositivos eléctricos que los productos designados únicamente por Supermicro. Attention Lors de l'installation du produit, utilisez les cables de connection fournis ou désigné ou achetez des cables, cables de puissance et adaptateurs respectant les normes locales et les conditions de securite y compris les tailles de cables et les prises electriques appropries. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et la Loi sur la Sécurité Matériel interdit l'utilisation de câbles certifies- UL ou CSA (qui ont UL ou CSA indiqué sur le code) pour tous les autres appareils électriques sauf les produits désignés par Supermicro seulement. ‫ כבלים חשמליים ומתאמי‬AC ‫!אזהרה‬ ‫ ספקים ומתאמים‬,‫ יש להשתמש בכבלים‬,‫ כאשר מתקינים את המוצר‬AC ‫ ואשר הותאמו לדרישות‬,‫אשר נרכשו או הותאמו לצורך ההתקנה‬ ‫ בהתאם‬.‫ עלול לגרום לתקלה או קצר חשמלי‬,‫ שימוש בכל כבל או מתאם מסוג אחר‬. ‫ כולל מידה נכונה של הכבל והתקע‬,‫הבטיחות המקומיות‬ ‫ קיים איסור להשתמש בכבלים המוסמכים ב‬,‫לחוקי השימוש במכשירי החשמל וחוקי הבטיחות‬- UL ‫או ב‬-CSA (‫כאשר מופיע עליהם קוד‬ ‫( של‬UL/CSA ‫ אלא רק במוצר אשר הותאם ע"י‬,‫ עבור כל מוצר חשמלי אחר‬Supermicro ‫בלבד‬. ‫ قم باستخدام التوصيالت املتوفرة أو املحددة أو قم برشاء الكابالت الكهربائية ومحوالت التيار املرتدد مع االلتزام بقوانني ومتطلبات السالمة املحلية مبا يف ذلك‬،‫عند تركيب املنتج‬ ‫ يحظر قانون السالمة لألجهزة الكهربائية واملعدات استخدام الكابالت املعتمدة‬.‫ استخدام أي كابالت ومحوالت أخرى قد يتسبب يف عطل أو حريق‬.‫حجم املوصل والقابس السليم‬ ‫ من قبل‬UL ‫ أو‬CSA ‫( والتي تحمل عالمة‬UL/CSA) ‫ مع أي معدات أخرى غري املنتجات املعنية واملحددة من قبل‬Supermicro. 123 Appendix B: Standardized Warning Statements 전원 케이블 및 AC 어댑터 경고! 제품을 설치할 때 현지 코드 및 적절한 굵기의 코드와 플러그를 포함한 안전 요구 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter Waarschuwing! Bij het aansluiten van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode, deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen, inclusief de juiste kabeldikte en stekker. Het gebruik van niet geschikte Kabels en/of Adapters kan een storing of brand veroorzaken. Wetgeving voor Elektrische apparatuur en Materiaalveiligheid verbied het gebruik van UL of CSA -gecertificeerde Kabels (met UL/CSA in de code) voor elke andere toepassing dan de door Supermicro hiervoor beoogde Producten. 124 Appendix C: System Specifications Appendix C System Specifications Processors Dual Intel® Xeon® Scalable processors in Socket P type sockets Note: Please refer to the motherboard specifications pages on our website for updates to supported processors. Chipset Intel C621 chipset BIOS 256 Mb AMI® Flash ROM Memory Twelve 288-pin DIMM sockets that can support up to 1.5TB of 72-bit ECC DDR4-2666 RDIMM or LRDIMM memory Note: See the memory section in Chapter 5 for details and our website for updates to supported memory. SATA Controller On-chip (Intel C621) controller Drive Bays Four 3.5" hot-swap drive bays to house four SATA drives PCI Expansion Slots One PCI-E 3.0 x32 slot with riser card (RSC-R1UW-2E16) One PCI-E 3.0 x16 slot mezzanine with SAS support One PCI-E 3.0 x16 slot with riser card (RSC-R1UW-E8R) Motherboard X11DDW-L: Extended ATX form factor (12 x 13 in. / 305 x 330 mm.) Chassis SC815TQC-605WB/R706WB; 1U Rackmount, 17.2 x 1.7 x 20 in. / 437 x 43 x 508 mm. (W x H x D) System Cooling Four 4-cm counter-rotating PWM fans Power Supply 6019P-WT: Model PWS-605P-1H (one power module) AC Input Voltages: 100-240 VAC Rated Input Current: 7.5 - 3.1A Rated Input Frequency: 50-60 Hz Rated Output Power: 600W Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (49A), -12V (0.5A), +5Vsb (3A) 6019P-WTR: Model PWS-706P-1R (two power modules for redundancy) AC Input Voltages: 100-240 VAC Rated Input Current: 8.5A to 6A Rated Input Frequency: 50-60 Hz Rated Output Power: 700/-50W Rated Output Voltages: +3.3V (25A), +5V (25A), +12V (700W: 58A at 100V-140V, 750W: 62A at 180V-240V), -12V (0.6A), +5Vsb (3A) Operating Environment Operating Temperature: 5º to 35º C (41º to 95º F) Non-operating Temperature: -40º to 60º C (-40º to 140º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) 125 SuperServer 6019P-WT/WTR User's Manual Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) Perchlorate Warning California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/ hazardouswaste/perchlorate” 126 Appendix D: UEFI BIOS Recovery Appendix D UEFI BIOS Recovery Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you do update the BIOS, do not shut down or reset the system while the BIOS is updating to avoid possible boot failure. D.1 Overview The Unified Extensible Firmware Interface (UEFI) provides a software-based interface between the operating system and the platform firmware in the pre-boot environment. The UEFI specification supports an architecture-independent mechanism that will allow the UEFI OS loader stored in an add-on card to boot the system. The UEFI offers clean, hands-off management to a computer during system boot. D.2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block (a main BIOS image). The recovery block contains critical BIOS codes, including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted. When the system power is turned on, the recovery block codes execute first. Once this process is complete, the main BIOS code will continue with system initialization and the remaining POST (Power-On Self-Test) routines. Note 1: Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS block crashes. Note 2: When the BIOS recovery block crashes, you will need to follow the procedures to make a Returned Merchandise Authorization (RMA) request. (For a RMA request, please see section 3.5 for more information). Also, you may use the Supermicro Update Manager (SUM) Out-of-Band (OOB) (https://www.supermicro.com.tw/products/nfo/SMS_SUM.cfm) to reflash the BIOS. D.3 Recovering the Main BIOS Block with a USB Device This feature allows the user to recover the main BIOS image using a USB-attached device without additional utilities used. A USB flash device such as a USB Flash Drive, or a USB CD/DVD ROM/RW device can be used for this purpose. However, a USB Hard Disk drive cannot be used for BIOS recovery at this time. 127 SuperServer 6019P-WT/WTR User's Manual The file system supported by the recovery block is FAT (including FAT12, FAT16, and FAT32) which is installed on a bootable or non-bootable USB-attached device. However, the BIOS might need several minutes to locate the SUPER.ROM file if the media size becomes too large due to the huge volumes of folders and files stored in the device. To perform UEFI BIOS recovery using a USB-attached device, follow the instructions below. 1. Using a different machine, copy the "Super.ROM" binary image file into the Root "\" directory of a USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use. Note 2: Before recovering the main BIOS image, confirm that the "Super.ROM" binary image file you download is the same version or a close version meant for your motherboard. 2. Insert the USB device that contains the new BIOS image ("Super.ROM") into your USB drive and reset the system when the following screen appears. 128 Appendix D: UEFI BIOS Recovery 3. After locating the healthy BIOS binary image, the system will enter the BIOS Recovery menu as shown below. Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update" and press the key. You will see the BIOS recovery progress as shown in the screen below. Note: Do not interrupt the BIOS flashing process until it has completed. 129 SuperServer 6019P-WT/WTR User's Manual 5. After the BIOS recovery process is complete, press any key to reboot the system. 6. Using a different system, extract the BIOS package into a USB flash drive. 7. Press continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press to save the settings and exit the BIOS Setup utility. 130 Appendix D: UEFI BIOS Recovery 8. When the UEFI Shell prompt appears, type fs# to change the device directory path. Go to the directory that contains the BIOS package you extracted earlier from Step 6. Enter flash.nsh BIOSname.### at the prompt to start the BIOS update process. Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system. 10. Press continuously to enter the BIOS Setup utility. 11. Press to load the default settings. 12. After loading the default settings, press to save the settings and exit the BIOS Setup utility. 131