Transcript

Surveyor HD with Ethernet over Coax This sheet supplements the information in the Installation and Operation manual for the Surveyor HD Camera Dome, XX214. It provides settings when using the Ethernet over coax option in the dome. Settings for the CE-1COAX The media converter module in the Surveyor HD is preconfigured to convert the IP signal to transmit it over coaxial cable. The settings on the CE-1COAX that will convert the signal back to IP are as follows: Set the Remote/Local DIP switch to Remote mode. Set the S1 DIP switch to the appropriate rate based on the maximum data rate: Off = 10BaseT; On = 100BaseT Set the S2 DIP switch to On for Master. For systems not utilizing PoE, connect the 12 VDC or 24 VAC power supply to the power connector of the CE-1COAX. A power adapter connector is provided to simplify connection. If there is no external power source connected, the CE-1COAX will try to detect PoE. Connect the IP camera RJ-45 connector to the 10/100BaseT Ethernet port of the CE-1COAX using a standard Cat5/6 cable, 100 m length (max). Connect one end of the long coax cable to the BNC connector of the CE-1COAX. Vicon Part Number 8009-5214-00-00 Copyright © 2012 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-2288 FAX: 631-951-2288 TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 WEB: www.vicon-security.com