Preview only show first 10 pages with watermark. For full document please download

Swi Series

   EMBED


Share

Transcript

SWI Series “Vital Links” MID PERFORMANCE INTERCONNECT CABLE ASSEMBLY Frequency Range: DC-18 GHz SWI-180 Group The SWI 180 Interconnect Assembly series incorporates low loss performance cable and precision connectors providing for a good interconnect cable. These cables are ideal for in-box or in-cabinet applications to 18 GHz. These assemblies feature low loss double shielded cable with a FEP Teflon jacket. The double shielded construction of these cables gives outstanding shielding effectiveness of greater than –85 dB @ 18 GHz. The assemblies feature precision stainless steel connectors designed to meet MIL-C-39012,MIL-STD-348a and are available in straight male, bulkhead female, and right angle male styles. These cable assemblies feature both low loss, excellent VSWR, and are excellent to increase the performance of any system. FEATURES Precision stainless steel connectors FEP outer jacket Double shielded for greater than -85 dB leakage at 18 GHz Low loss PTFE tape dielectric CONNECTORS N, SMA, TNC, Straight male, right angle male, bulkhead female CABLE SIZE 0.180 inches, nominal outer diameter; 6 inches, 12 inches, 18 inches, 24 inches, 30 inches 36 inches standard lengths APPLICATIONS General purpose, low loss interconnections High temperature (+200°C) environments Cable Construction 1. 2. 3. 4. 5. Center conductor: Silver plated copper * Dielectric: Microporous PTFE tape Outer conductor: Silver plated copper flat braid* Braid: Silver plated copper round braid * Jacket options: Extruded FEP * Silver plating per ASTM-B-298 Teflon is a registered trademark of the DuPont Corporation 5550 E. McDowell Rd. | Mesa, AZ 85215 | tel: 480.985.9000 | fax: 480.985.0334 |800.778.4401 http://www.semflex.com SWI Series “Vital Links” MID PERFORMANCE INTERCONNECT CABLE ASSEMBLY Frequency Range: DC-18 GHz SWI-180 Group 50 ELECTRICALS dB/ft Impedance Capacitance Delay Breakdown Voltage Nominal pF/ft (pF/m) ns/ft (ns/m) KV MECHANICAL/ENVIRONMENTAL Nominal Diameter Minimum Bend Radius Temperature Weight .195 (.495) 1.0 (2.54) -65/+200 .05 (74.31) inches (cm) inches (cm) DEG. C lb/ft (g/m) MATERIALS AND FINISHES CONNECTORS Stainless steel Stainless steel Silicon Rubber BeCu / Gold plated PTFE MATERIALS AND FINISHES CABLE Cable Jacket Outer Shield Inter Conductor Dielectric Center Conductor FEP Silver Copper Silver Copper Micro-porous PTFE Silver Copper 45 40 Attenuation (db/100ft) 76.5 -100 50 27 (88.58) 1.34 (4.40) >12 % Body Nut Gasket Contact Insulator SW180 CABLE ATTENUATION vs FREQUENCY 35 30 25 20 15 10 5 0 0 2.5 5 7.5 10 12.5 15 17.5 20 Frequency (GHz) Standard Lengths of 6 inches, 12 inches, 18 inches, 24 inches, 30 inches, 36 inches FOR OTHER CONFIGURATION AND LENGTHS CONTACT SEMFLEX: [email protected] 5550 E. McDowell Rd. | Mesa, AZ 85215 | tel: 480.985.9000 | fax: 480.985.0334 |800.778.4401 http://www.semflex.com