Transcript
SWITCH MODE POWER SUPPLY INSTRUCTION MANUAL
MODEL
SS-505 SWITCH-MODE POWER SUPPLY
METER
V.ADJ V
POWER ON
A MIN
MAX
VARIABLE continuous
OFF
DAIWA `s slim,compact,lightweight, and highly efficient switch-mode power supply is capable of delivering 50A at all DC OUTPUT VOLTAGES. DAIWA only gives you a 50A switch-mode power supply.
■ FEATURES ●
●
●
● ● ●
■ FRONT PANEL (SS-505) VOLT / AMPERE SWITCH METER (V/A) SWITCH-MODE POWER SUPPLY
POWER ON
MAX 6A
− − + DC OUTPUT
MAX 6A
3.8kg
METER
V.ADJ
DC OUTPUT
MAX
5∼15V
50A
V. ADJ VOLUME (5∼15V)
ー
OFF
■ Standard accessories 1.AC corde : 1 pc.
RATED CURRENT USE ONLIY WITH 250V FUSE
50A GROUND
WIDE INPUT VOLTAGE RANGE WITH OVER VOLTAGE PROTECTION PERFORMANCE WITHOUT COMPROMISE
WARNING LAMP
AC INPUT
+
A
SS-505
AC100 - 117V AC220 - 240V AC90 - 123V AC180 - 245V DC5 - 15V 50A (Max55A ) Less than 1.5% Less than 5mV 84% at 35A CUT OFF 56A 920W 15A 8A 216W×110H×280D only 3.8Kg
(SS-505H:without) CIGARETTE LIGHTER SOCKET (MAX 10A)
VARIABLE continuous
AC LINE LAMP
+
■ REAR PANEL (SS-505)
MIN
PROTECTOR
SS-505
SS-505 INPUT VOLTAGE *INPUT VOLTAGE RANGES OUTPUT VOLTAGE OUTPUT CURRENT VOLTAGE FLUCTUATION RIPPLE VOLTAGE CONVERSION RATIO PROTECTION POWER CONSUMPTION FUSE DIMENSIONS (mm) WEIGHT
V
AC LINE
PROTECTOR
■ SPECIFICATIONS
1/4 the weight (3.8Kg), and 1/3 the size of conventional power supplies. The use of high speed F.E.T. technology ensures 84% conversion efficiency. 50A available at all DC output voltages. (5V∼15V) (SS-505H:TYPE 25A available at the ranges of 10-30V (DC output voltages.)) Can be used for DC motors requiring peak starting currents. Automatic cooling fan. Perfect for laboratory, industrial, and ham radioapplications.
POWER SWITCH
WIDE INPUT VOLTAGE RANGE WITH OVER VOLTAGE PROTECTION PERFORMANCE WITHOUT COMPROMISE
AC LINE
+ MAX 6A
− − + DC OUTPUT
MAX 6A
4P TERMINALS ( MAX 6A )
DC OUT PUT
GROUND EARTH
FAN MOTOR
AC FUSE
■ CAUTION
1) PLEASE DON`T USE AS A CAR BATTERY CHARGER. 2) Use only in a well ventilated place. 3) Connect the AC plug directly to an AC wall socket. 4) Connect the chassis of the unit to the ground earth. 5) At high internal temperatures, the protecttion circuit will limit the output current. 6) Due to the presence of large magnetic field, please ensure that the output cable of the SS-505 is kept as far away from your antenna connecting cable as possible. 7) Be sure to use at least 5.5mm diameter wire.
DAIWA INDUSTRY CO.,LTD Foreign trade div. 3-36-6 Ikegami, Ota-ku, TOKYO, 146-0082, JAPAN. Phone:03-3755-5645 Fax:03-3755-2253 URL: http://www.daiwa-industry.co.jp