Transcript
SX1018HP Ethernet Managed Blade Switch User Guide for HP c-Class BladeSystems PNs: SX1018HP Rev 1.0
www.mellanox.com
Rev 1.0
NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Mellanox Technologies 350 Oakmead Parkway Suite 100 Sunnyvale, CA 94085 U.S.A. www.mellanox.com Tel: (408) 970-3400 Fax: (408) 970-3403
Mellanox Technologies, Ltd. Beit Mellanox PO Box 586 Yokneam 20692 Israel www.mellanox.com Tel: +972 (0)74 723 7200 Fax: +972 (0)4 959 3245
© Copyright 2013. Mellanox Technologies. All Rights Reserved. Mellanox®, Mellanox logo, BridgeX®, ConnectX®, CORE-Direct®, InfiniBridge®, InfiniHost®, InfiniScale®, MLNX-OS®, PhyX®, SwitchX®, UFM®, Virtual Protocol Interconnect® and Voltaire® are registered trademarks of Mellanox Technologies, Ltd. Connect-IB™, FabricIT™, Mellanox Open Ethernet™, MetroX™, MetroDX™, ScalableHPC™, Unbreakable-Link™ are trademarks of Mellanox Technologies, Ltd. All other trademarks are property of their respective owners.
2
Mellanox Technologies
Document Number: 4159
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
Table of Contents Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 HP contact information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 1 Preparing for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.1 1.2 1.3 1.4
Audience. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Kit contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Mellanox SX1018HP Ethernet Switch Connector Bays . . . . . . . . . . . . . . . . 10 Mellanox SX1018HP Ethernet Switch LEDs. . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 2 Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1 2.2
Installing the Mellanox SX1018HP Ethernet Switch . . . . . . . . . . . . . . . . . . . 13 Installing and Removing Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 3 Configuring the Switch the First Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Chapter 4 Removing the Mellanox SX1018HP Ethernet Switch for Service . . . . . . . . 22 Chapter 5 Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10
Regulatory Compliance Identification Numbers . . . . . . . . . . . . . . . . . . . . . . Federal Communications Commission Notice . . . . . . . . . . . . . . . . . . . . . . . . Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Canadian notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . European Union regulatory notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Japanese class A notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BSMI Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Korean class A notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chinese notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 23 23 23 23 23 25 25 25 25
Mellanox Technologies
3
Rev 1.0
List of Figures Figure 1: Figure 2:
SX1018HP Ethernet Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 HP BLade System Onboard Administrator . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9:
QSFP Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Breakout or Fanout Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Port Splitting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Removing a Divider from the HP BladeSystem c7000 Enclosure Bay . . . . . 13 Install Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 QSFP+ Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 10: Figure 11: Figure 12: Figure 13: Figure 14:
Cable Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cable Connected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Removing the Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 For EU harmonized telecommunications products . . . . . . . . . . . . . . . . . . . . 24 For EU non-harmonized telecommunications products . . . . . . . . . . . . . . . . 24
4
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
List of Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8
Document Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Reference Documents and Web Sites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 LED Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 QSFP Cable Connector Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Serial Terminal Program Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Configuration Wizard Session - DHCP Configuration (Example) . . . . . . . . 17 Configuration Wizard Session - Static IP Configuration . . . . . . . . . . . . . . . . 19 Configuration Wizard Session - Zeroconf Configuration. . . . . . . . . . . . . . . . 20
Mellanox Technologies
5
Rev 1.0
Revision Table 1 - Document Revision History Date
Revision
Description of changes
April 2013
1.0
Initial release
Documentation Feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (
[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback.
HP contact information For United States and worldwide contact information, see the Contact HP website (http://www.hp.com/ ). In the United States: •
To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be recorded or monitored.
•
It you have purchased a Care Pack (service upgrade), see the Support & Drivers website
(http://www8.hp.com/us/en/support-drivers.html). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website ((http://www.hp.com/services/carepack).
6
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
About this Manual This manual describes the installation and basic use of the Mellanox SX1018HP switch which is based on the SwitchX-2 switch device.
Related Documentation Additional Documentation available from Mellanox: Table 2 - Reference Documents and Web Sites Document Name
HP BladeSystem Technical Resources
Description
You can download the documentation for components referenced in this installation guide from the HP Blade System Technical Resources website: http://www.hp.com/go/bladesystem/documentation Check the HP BladeSystem Technical Resources Website frequently for updates.
HP BladeSystem Onboard Administrator User Guide
http://www.hp.com/support/ BladeSystem_Onboard_Administrator_UG_en
Various HP BladeSystem Onboard Administrator Manuals
http://www.hp.com/support/ BladeSystem_Onboard_Administrator_Manuals_en
HP BladeSystem Onboard Administrator CLI User Manual
http://www.hp.com/support/ BladeSystem_Onboard_Administrator_CLI_UG_en
HP BladeSystem Onboard Administrator - How to Make "SHOW ALL" Inventory Report
http://www.hp.com/support/ BladeSystem_Onboard_Administrator_SHOW_ALL_Inv_Rpt_en
HP CLI Reference Manual
http://www.hp.com/support/MLNX-OS_CLI_SX1018HP_UG_en
HP MLNX-OS User Manual
http://www.hp.com/support/ MLNX_OS_EthernetManagedBladeSwitch_UG_en
HP SW release Notes for the MLNX-OS software
http://www.hp.com/support/MLNX-OS_SX1018HP_RN_en
All of these documents can be found on the Mellanox Website. They are available either through the product pages or through the support page with a login and password.
Conventions Throughout this manual, the name and the term switch are used to describe the switch unless explicitly indicated otherwise.
Mellanox Technologies
7
Rev 1.0
The following icons are used throughout this document to indicate information that is important to the user.
This icon indicates information that is helpful to the user.
This icon indicates a situation that can potentially cause damage to hardware or software.
BEWARE! This icon indicates a situation that can potentially cause personal injury or damage to hardware or software.
This icon makes a recommendation.
8
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
1
Preparing for Installation
1.1
Audience This document is intended for HP service representatives and other persons trained to install hardware options in HP BladeSystem configurations. Such persons are expected to understand the hazards of working in this environment and to take suitable precautions to minimize danger to themselves and others.
1.2
Kit contents The kit contains the following items: • Mellanox SX1018HP Ethernet Switch for HP c-Class BladeSystems—689638-B21 (see Figure 1) • Warranty documentation
This kit does not include cables. You must order the cables separately.
Figure 1: SX1018HP Ethernet Switch hp UID
ellanox SX1018HP Ethernet Switch
P
L/A P
1
L/A P
2
L/A P
3
L/A P
4
L/A P
5
L/A
6
P
L/A P
7
L/A P
8
L/A
9
P
L/A P
10
L/A P
11
L/A
12
P
L/A P
13
L/A P
14
L/A P
15
L/A P
16
L/A P
17
Your particular switch might look slightly different.
Additional information Mezzanine NIC installation determines interconnect bay assignments for switch installation. For more information on the association between the mezzanine connector and the interconnect bays, see the following documents under Mezzanine-to-Interconnect Mappings on the HP BladeSystem Technical Resources website: • HP BladeSystem c7000 Enclosure Setup and Installation Guide: http://www.hp.com/go/bladesystem/documentation For specific port connections for each server blade, see the HP BladeSystem Onboard Administrator User Guide. Connections differ by server blade type. The information contained in this document explains the cabling between the SX1018HP Ethernet Switch and the network switches. The HP Onboard Administrator screen example (see Figure 2) is a reference for port mapping.
Mellanox Technologies
9
L/A
18
Rev 1.0
Preparing for Installation
Figure 2: HP BLade System Onboard Administrator
40GbE is supported in interconnect bays 3 to 8 only.
Your screen image might vary by switch type.
You can install up to 18 cables in the uplink ports on the SX1018HP Ethernet Switch.
1.3
Mellanox SX1018HP Ethernet Switch Connector Bays Figure 3: QSFP Connectors
hp UID
ellanox SX1018HP Ethernet Switch
P
L/A P
1
1.3.1
L/A P
2
L/A P
3
L/A P
4
L/A P
5
L/A
6
P
L/A P
7
L/A P
8
L/A
9
P
L/A P
10
L/A P
11
L/A
12
P
L/A P
13
L/A P
14
L/A P
15
L/A P
16
L/A P
17
Uplink Ports The ports labelled 1 to 18 are external uplink ports. You can install up to 18 40GbE QSFP+ cables or combinations of 40 GbE and 10GbE ports. The maximum number of 10GbE ports available using this switch and breakout cables is 34.
1.3.2
Breakout Cables Splitting the Data Stream Using Breakout (Fanout) Cables. Specific ports can be split by using a QSFP 1X4 breakout cable to split one 40 GbE port into 4 lanes (4 SFP+ connectors 10GbE each). These 4 lanes then go, one lane to each of the 4 SFP+ connectors. Some ports can be split into 2 10 Gb/s ports, using lanes 1 and 2 only. When a QSFP
10
Mellanox Technologies
L/A
18
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
port is split into 2 10Gb/s ports, then only SFP+ connectors #1 and #2 are used. Connectors #3 and #4 are left unconnected. Figure 4: Breakout or Fanout Cable
Figure 5: Port Splitting Options 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
This port is split-able into 4 10Gb/s SFP+ ports This port is split-able into 2 10Gb/s SFP+ ports This port is unmapped
1.3.3
Mini USB The mini USB in between uplink ports 9 and 10 is a debug port. This is for use by HP FAEs and qualified service technicians only.
Mellanox Technologies
11
Rev 1.0
1.4
Preparing for Installation
Mellanox SX1018HP Ethernet Switch LEDs Figure 6: Switch LEDs
4
3 1
ellanox SX1018HP Ethernet Switch UID
P
L/A P
L/A P
L/A P
L/A P
L/A P
L/A
2 1
2
3
Table 3 - LED Assignments Item
Description
Status
1
Unit ID LED
Blue = Activated Off = Deactivated
2
Internal health LED
Green = Normal Amber = Component degraded Off = Power off
3
Physical Link LED
Off = no link Green = Physical link up Blinking green = error detected.
4
Logical Link Activity LED
Amber = no traffic Blinking amber = traffic
The logical link activity LED flashes with greater frequency as network activity increases.
12
Mellanox Technologies
4
5
6
SX1018HP Ethernet Managed Blade Switch HW User Manual
2
Rev 1.0
Hardware Installation This chapter contains the following sections:
2.1
•
Installing the Mellanox SX1018HP Ethernet Switch
•
Installing and removing cables in the Mellanox SX1018HP Ethernet Switch
Installing the Mellanox SX1018HP Ethernet Switch
All panels and doors should be in place and securely fastened while the unit is in operation for proper cooling and for EMI emissions control.
2.1.1
Prepare the Interconnect Module Bay in the HP BladeSystem c7000 Enclosure To prepare the interconnect module bay in the HP BladeSystem c7000 enclosure, follow these steps: 1. Remove any devices or blanks. 2. To remove the divider, press the divider release button and slide the divider out of the interconnect module bay (see Figure 7). Figure 7: Removing a Divider from the HP BladeSystem c7000 Enclosure Bay
3. Press the divider release button. 4. Slide divider out from the interconnect module bay. Mellanox Technologies
13
Rev 1.0
2.1.2
Hardware Installation
Install the Mellanox SX1018HP Ethernet Switch into the HP BladeSystem Enclosure To install the Mellanox SX1018HP Ethernet Switch into the HP BladeSystem c7000 enclosure, follow these steps: 1. Slide the Mellanox SX1018HP Ethernet Switch all the way into the HP BladeSystem c7000 enclosure (see Figure 8). 2. Push the blade handle in until it is in the locked position (see Figure 8). The blade handle is locked when you can not pull it back out without pushing the blade handle release. Figure 8: Install Blade
2.2
Installing and Removing Cables Figure 9 shows a cable with a QSFP+ connector used with the Mellanox SX1018HP Ethernet Switch. QSFP+ connector to QSFP+ connector cables are used to connect multiple Mellanox SX1018HP Ethernet Switches together. For example, you might connect two or more c-Class interconnect modules together, for example, when another switch is installed in another HP BladeSystem c7000 enclosure that is mounted in the same rack. The Mellanox SX1018HP Ethernet Switches are connected together by the QSFP+ to QSFP+ cables to form a high-performance network.
14
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
Figure 9: QSFP+ Cable Connector
3 1
2
72 mm max
18.35 mm
Table 4 - QSFP Cable Connector Description
1
Cable
2
QSFP+ connector release pull tab
3
QSFP+ connector
The cables are not included in this kit and must be purchased separately.
2.2.1
Installing a Cable in the Mellanox SX1018HP Ethernet Switch To install a cable in the Mellanox SX1018HP Ethernet Switch, follow these steps: 1. Align the cable QSFP+ connector with the Mellanox SX1018HP Ethernet Switch port ( Figure 10). 2. Insert the QSFP+ connector into the Mellanox SX1018HP Ethernet Switch port (Figure 10) until it is fully engaged and locked. Figure 10: Cable Installation
1
QSFP+ connector
2
Mellanox SX1018HP Ethernet Switch - port # 1
3
Cable
Mellanox Technologies
15
Rev 1.0
Hardware Installation
Figure 11: Cable Connected
1
Cable installed in port 1 of the Mellanox SX1018HP Ethernet Switch.
2
Mellanox SX1018HP Ethernet Switch.
You can install up to 18 cables in the Mellanox SX1018HP Ethernet Switch. It is not necessary to install the cables in any particular order.
2.2.2
Removing a Cable from the Mellanox SX1018HP Ethernet Switch To remove a cable from the Mellanox SX1018HP Ethernet Switch, pull the QSFP+ connector release tab (Figure 9) which releases the connector while using your other hand to remove the connector from the switch port. To completely remove the cable, it might be necessary to remove a releasable cable tie on the HP c-Class blade cable management bracket. If it is necessary to remove a releasable cable tie from the cable management bracket to fully release a QSFP+ connector from the switch, reverse the installation procedure documented in the cable management bracket installation guide.
16
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
3
Rev 1.0
Configuring the Switch the First Time The procedures described in this chapter assume that you have already installed and powered-on your switch according to the instructions in this document. Step 1.
If you are not already connected to the Onboard Administrator, connect to the Onboard Administrator of the Chassis using the serial port to your laptop. For more information see the http://www.hp.com/support/ BladeSystem_Onboard_Administrator_UG_en
Step 2.
Connect to the HP Onboard Administrator and run “connect interconnect
”.
No remote IP connection is available at this stage.
Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on your host PC with the settings described in Table 5.
Step 3.
Table 5 - Serial Terminal Program Configuration Parameter
Setting
Baud Rate
9600
Data bits
8
Stop bits
1
Parity
None
Flow Control
None
Step 4.
Login (from a serial terminal program) as admin and use admin as password. This starts the Mellanox configuration wizard.
Step 5.
Go through the Mellanox configuration wizard. Table 6 shows an example of a wizard session.
Table 6 - Configuration Wizard Session - DHCP (Sheet 1 of 2)Configuration (Example) Wizard Session Display
Comments
Mellanox configuration wizard Do you want to use the wizard for initial configuration? yes
You must perform this configuration the first time you operate the switch or after resetting the switch. Type ‘y’ and then press .
Step 1: Hostname? [switch]
If you wish to accept the default hostname, then press . Otherwise, type a different hostname and press .
Mellanox Technologies
17
Rev 1.0
Configuring the Switch the First Time
Table 6 - Configuration Wizard Session - DHCP (Sheet 2 of 2)Configuration (Example) Wizard Session Display
Comments
Step 2: Use DHCP on mgmt0 interface? [no] yes
Perform this step to obtain an IP address for the switch. (mgmt0 is the management port of the switch.) If you wish the DHCP server to assign the IP address, type ‘yes’ and press . If you type ‘no’ (no DHCP), then you will be asked whether you wish to use the ‘zeroconf’ configuration or not. If you enter ‘no’ (no Zeroconf), then you need to enter a static IP, and the session will continue.
Step 3: Enable IPv6? [yes]
The management interface will be able to use IPv6 addresses.
Step 4: Enable IPv6 auto-config This turns on auto-configuration of the IPv6 addresses. (SLAAC) on mgmt0 interface? This is unsuitable for DHCPv6. [no]
18
Step 5: Enable DHCPv6 on mgmt0 interface? [no]
To enable DHCPv6 on the MGMT0 interface.
Step 6: Admin password (Press to leave unchanged)? Step 6: Confirm admin password?
To avoid illegal access to the machine, please type a password and then press . Then confirm the password by re-entering it.
You have entered the following information:
The wizard displays a summary of your choices and then asks you to confirm the choices or to re-edit them.
To change an answer, enter the step number to return to or hit to save changes and exit. Choice: Configuration changes saved.
Either press to save changes and exit, or enter the configuration step number that you wish to return to.
Mellanox Technologies
Note that password characters are not printed.
Note: To re-run the configuration wizard run the command “configuration jump-start” in Config mode.
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
. Table 7 - Configuration Wizard Session - Static IP Configuration Wizard Session Display - Static IP Configuration (Example)
Mellanox configuration wizard Do you want to use the wizard for initial configuration? yes Step 1: Hostname? [switch] Step 2: Use DHCP on mgmt0 interface? [yes] no Step 3: Use zeroconf on mgmt0 interface? [no] Step 4: Primary IP address? [for example 192.168.10.4] 10.10.10.10 Mask length may not be zero if address is not zero (interface eth0) Step 5: Netmask? [0.0.0.0] 255.255.255.0 Step 6: Default gateway? [for example 192.168.10.1] 10.10.10.255 Step 7: Primary DNS server? Step 8: Domain name? Step 9: Enable IPv6? [yes] Step 10: Enable IPv6 autoconfig (SLAAC) on mgmt0 interface? [no] Step 11: Admin password (Enter to leave unchanged)? To change an answer, enter the step number to return to. Otherwise hit to save changes and exit. Choice: Configuration changes saved. To return to the wizard from the CLI, enter the "configuration jump-start" command from configure mode. Launching CLI... switch>
Mellanox Technologies
19
Rev 1.0
Configuring the Switch the First Time
Table 8 - Configuration Wizard Session - Zeroconf Configuration Wizard Session Display - IP Zeroconf Configuration (Example)
Mellanox configuration wizard Do you want to use the wizard for initial configuration? yes Step 1: Hostname? [switch] Step 2: Use DHCP on mgmt0 interface? [yes] no Step 3: Use zeroconf on mgmt0 interface? [no] yes Step 4: Default gateway? [For example:192.168.10.1] Step 5: Primary DNS server? Step 6: Domain name? Step 7: Enable IPv6? [yes] Step 8: Enable IPv6 autoconfig (SLAAC) on mgmt0 interface? [no] Step 9: Admin password (Enter to leave unchanged)? To change an answer, enter the step number to return to. Otherwise hit to save changes and exit. Choice: Configuration changes saved. To return to the wizard from the CLI, enter the "configuration jump-start" command from configure mode. Launching CLI... switch> Step 6.
Before attempting a remote (for example, SSH) connection to the switch, check the mgmt0 interface configuration. Specifically, verify the existence of an IP address. To check the current mgmt0 configuration, enter the following commands:
switch > enable switch # configure terminal switch (config)# show interfaces mgmt0
The following is an example of the output: Interface mgmt0 state
20
Admin up:
yes
Link up:
yes
IP address:
192.168.10.4
Netmask:
255.255.255.0
Speed:
1000Mb/s (auto)
Duplex:
full (auto)
Interface type:
ethernet
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
Rev 1.0
Interface source:
physical
MTU:
1500
HW address:
00:02:C9:11:2A:AE
Comment:
RX bytes:
1343502058
TX bytes:
313920869
RX packets:
17589211
TX packets:
992717
RX mcast packets:
0
TX discards:
0
RX discards:
0
TX errors:
0
RX errors:
0
TX overruns:
0
RX overruns:
0
TX carrier:
0
RX frame:
0
TX collisions:
0
TX queue len:
1000
Mellanox Technologies
21
Rev 1.0
4
Removing the Mellanox SX1018HP Ethernet Switch for Service
Removing the Mellanox SX1018HP Ethernet Switch for Service Put the HP 10K series rack and the HP BladeSystem c7000 enclosure into a safe and stable state for component removal and bring the component to an appropriate state for removal. You must ensure that you can reach the component easily and handle it safely. For more information about removing c-Class components from the c-Class enclosure, see the HP BladeSystem c7000 Enclosure Service and Maintenance Guide: http://www.hp.com/go/bladesystem/documentation To remove the switch, follow these steps: 1. Disconnect and remove each cable until all of the networking ports are unplugged. When disconnecting the cables, ensure that you do not bend them more than the recommended bend radius. It might be necessary to loosen the releasable cable ties enough to remove the cable from the switch. HP recommends that you do not remove the cables from the releasable cable ties on the c-Class cable management bracket. 2. Press the switch blade handle release button and slide the switch all the way out of the HP BladeSystem c7000 enclosure. Figure 12: Removing the Blade
HP provides various cable management solutions. Installation and removal of the Mellanox SX1018HP Ethernet Switch might depend on which type of cable management bracket is used to support the cables used in your configuration.
If you are unsure of the process to remove a switch for service, contact an HP service representative. Also check the HP BladeSystem Technical Resources web page frequently for updates to this guide: http://www.hp.com/go/bladesystem/documentation 22
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
5
Rev 1.0
Regulatory Compliance The chapter lists all of the regulatory notices of compliance for the Mellanox SX1018HP Ethernet Switch.
5.1
Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.
5.2
Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
5.3
Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.
5.4
Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
5.5
Canadian notice This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
5.6
European Union regulatory notice Products bearing the CE marking comply with the following EU Directives: •
Low Voltage Directive 2006/95/EC
•
EMC Directive 2004/108/EC
•
Ecodesign Directive 2009/125/EC, where applicable
CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP.
Mellanox Technologies
23
Rev 1.0
Regulatory Compliance
Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website (http://www.hp.eu/certificates) (type the product number in the search field). The compliance is indicated by one of the following conformity markings placed on the product: Figure 13: For EU harmonized telecommunications products
Figure 14: For EU non-harmonized telecommunications products
Please refer to the regulatory label provided on the product. The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, GERMANY.
24
Mellanox Technologies
SX1018HP Ethernet Managed Blade Switch HW User Manual
5.7
Japanese class A notice
5.8
BSMI Notice
5.9
Korean class A notice
5.10
Chinese notice
Rev 1.0
Mellanox Technologies
25