Preview only show first 10 pages with watermark. For full document please download

Sy Ms121 Manual

   EMBED


Share

Transcript

SY-MS121 / SY-MS121-AP Installation Guide SY-MS121 and SY-MS121-AP Presentation Switcher with Multi-Format Inputs and Outputs 4 HDMI, 4 VGA, 1 Component video, 2 Composite video & 1 S-video inputs – Simultaneous HDMI, VGA & HDBaseT outputs SY Electronics Ltd, Unit 7, Worrall Street, Salford, Greater Manchester, M5 4TH, United Kingdom Tel: +44 (0) 161 868 3450 – Fax: +44 (0) 161 868 3459 – www.sy.co.uk SY-MS121 / SY-MS121-AP The SY-MS121 and SY-MS121-AP are multi-format switchers with 4 HDMI inputs, 4 VGA inputs and 2 composite video inputs, 1 component video input and 1 S-video input. Each of these inputs are presented to all the output video connectors simultaneously. The resolution of the outputs can be set to one of five resolutions. Each input type and source can have different resolutions, but the output resolution will always be the one shown by the Resolution LEDs on the front panel. As such the input video signal may be up-scaled or down-scaled as necessary, providing consistent output resolution as required. This Presentation Switcher is well suited to a wide range of applications in AV industry, Digital Signage and at home; particularly when multiple source resolutions and formats are in use. Features       HDMI, VGA, Composite, Component and S-Video inputs HDMI, VGA and HDBaseT outputs Parallel switching of audio inputs Five selectable output display resolutions (1024 x 768 to 1920 x 1080p) Built-in stereo power amplifier (2 x 10W @ 8R) Supports 3D and CEC Connectors and Controls Front Figure 1 – SY-MS121 Front View Figure 2 – SY-MS121-AP Front View Name Power LED IR Sensor HDMI Button & LED VGA Button & LED VIDEO Button & LED Channel Buttons & LEDs Transmitter Power Status LED Built-In IR sensor Select HDMI input Group Select VGA input Group Select Composite, Component or S-Video input Group Select one of 4 input channel of selected group Resolution Button & LEDs Select output resolution MIC VOLUME and MUTE Up / Down buttons for MIC level - MUTE button to mute the MIC input LINE VOLUME and MUTE Up / Down buttons for LINE level - MUTE button to mute the LINE input www.sy.co.uk SY-MS121 / SY-MS121-AP Rear Figure 3 - SY-MS121 Rear View Figure 4 - SY-MS121-AP Rear View Name Earthing Screw AUDIO HDBaseT Transmitter Use to bond the SY-MS121 to a local earth (ground) point Phono connectors for stereo line level audio output RJ45 HDBaseT 70m output – (SY-MS121-AP only) VGA VGA video output HDMI HDMI output VGA INPUTS Four VGA inputs HDMI INPUTS Four VGA inputs AUDIO INPUTS Four line-level audio inputs, corresponding to the VGA input selection VIDEO INPUTS Composite video on inputs one and four, component video (YPbPr) on input two and S-Video on input three RS232 control port for the Presentation Switcher RS232 USB ETHERNET Service only - Firmware updates Ethernet control port – (SY-MS121-AP only) LINE Balanced line input (line level signals only) MIC Balanced microphone input (microphone/signal level only) SPEAKER Stereo speaker output – 2 x 10W @ 8R IEC Mains Mains AC input (110V to 240V AC, 50 / 60 Hz) Using the Presentation Switcher Connect all the available video inputs present in the installation to the appropriate input connectors and, if required, any analogue audio signals to the corresponding audio inputs. Note that the audio inputs in the VIDEO INPUTS section are shared between inputs one and three and also between inputs two and four. Connect the display devices to the outputs as required or use the HDBaseT output where the display is too far for a standard cable run for either the HDMI or the VGA outputs. Note that both the SY-HDBT-70P-R and the SY-HDBT-100-R receivers provide only HDMI output. To select an input, start by pressing the button for the source type, HDMI, VGA or VIDEO, then press the channel button you wish to display from that group. The MIC and LINE audio inputs are sent to all the audio outputs simultaneously and their levels can be individually controlled from the front panel buttons. www.sy.co.uk SY-MS121 / SY-MS121-AP Output Resolutions The Resolution button sets the output resolution in accordance with the following table. Be sure to check that the display device is capable of using the resolution before selecting it. Indicated Resolution 1024 x 768 1280 x 720p 1280 x 800 1360 x 768 1920 x 1080p Output Parameters XGA – 1024 x 768 @ 60 Hz 720p – 1280 x 720 @ 60 Hz WXGA – 1280 x 800 @ 60 Hz WXGA – 1360 x 768 @ 60 Hz 1080p – 1920 x 1080 @ 60 Hz Input Resolutions The inputs to the Presentation Switcher must be compliant with any of the following resolutions: Input Resolution 640 x 480 @ 60 Hz (VGA) 640 x 480 @ 72 Hz (VGA) 640 x 480 @ 75 Hz (VGA) 720 x 400 @ 70 Hz (VGA) 720 x 480 @ 60 Hz Interlaced (525 lines) 720 x 480 @ 60 Hz Progressive (525 lines) 720 x 576 @ 50 Hz Interlaced (625 lines) 720 x 576 @ 50 Hz Progressive (625 lines) 800 x 600 @ 56 Hz Interlaced 800 x 600 @ 60 Hz (SVGA) 800 x 600 @ 72 Hz (SVGA) 800 x 600 @ 75 Hz (SVGA) 1024 x 768 @ 60 Hz (XGA) 1024 x 768 @ 70 Hz (XGA) 1024 x 768 @ 75 Hz (XGA) 1280 x 720 @ 60 Hz Interlaced (720i) 1280 x 720 @ 60 Hz Progressive (720p) 1280 x 720 @ 60 Hz (HD/WXGA) 1280 x 1024 @ 75 Hz (SXGA) 1360 x 768 @ 60 Hz (WXGA) 1920 x 540 @ 60 Hz (1080i) 1920 x 1080 @ 50 Hz (1125 lines, interlaced, 1080i) 1920 x 1080 @ 60 Hz (1125 lines, interlaced, 1080i) 1920 x 1080 @ 50 Hz (1250 lines, interlaced, 1080i) 1920 x 1080 @ 50 Hz (1250 lines, progressive, 1080p) 1920 x 1080 @ 60 Hz (1250 lines, progressive, 1080p) www.sy.co.uk HDMI In Y Y Y VGA In Y Y Video In Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y SY-MS121 / SY-MS121-AP RS232 Control Commands The SY-MS121 and SY-MS121-AP Presentation Switcher can also be controlled via RS232 from a programmed push button panel or a computer. The following table lists the more commonly used RS232 commands. The RS232 data rate is 9600 bps, 8 data bits, 1 stop bit and no parity. Function MUTE LINE input UnMute LINE input Increase LINE Volume Decrease LINE Volume Set LINE Volume from 00 to 99 Lock the front panel controls Unlock the front panel controls Auto-adjust the VGA input Auto-adjust the colour temperature Set the output resolution to 1360x768 HD Set the output resolution to 1280x768 XGA Set the output resolution to 1280x800 WXGA Set the output resolution to 1920x1080 1080P Select HDMI Input 1 Select HDMI Input 2 Select HDMI Input 3 Select HDMI Input 4 Select VGA Input 1 Select VGA Input 2 Select VGA Input 3 Select VGA Input 4 Select AV1 Input Select YPbPr Input Select S-Video Input Select AV2 Input Mute LINE and MIC Unmute LINE and MIC Mute MIC Input Unmute MIC Input Increase MIC Volume Decrease MIC Volume Set MIC Volume from 00 to 99 RS232 Command 0600% 0601% 0602% 0603% 01XX% 0604% 0605% 0606% 0607% 0618% 0618% 0618% 0619% 0701% 0702% 0703% 0704% 0705% 0706% 0707% 0708% 0709% 0710% 0711% 0712% 0720% 0721% 0722% 0723% 0724% 0725% 08XX% www.sy.co.uk Response Example LINE MUTE On LINE MUTE Off LINE Volume: XX LINE Volume: XX LINE Volume: XX Panel Locked Panel UnLocked VGA Adjustment Color Temp: XX Resolution: HD 1360X768 Resolution: XGA 1280X768 Resolution: WXGA 1280X800 Resolution: 1080P 1920x1080 Source: HDMI 1 Source: HDMI 2 Source: HDMI 3 Source: HDMI 4 Source: VGA1 Source: VGA2 Source: VGA3 Source: VGA4 Source: CVIDEO1 Source: YPbPr Source: SVIDEO Source: CVIDEO2 Mute On Mute Off MIC Mute On MIC Mute Off MIC Volume: XX MIC Volume: XX MIC Volume: XX SY-MS121 / SY-MS121-AP Figure 5 – SY-MS121 Configuration Example Figure 6 – SY-MS121-AP Configuration Example www.sy.co.uk SY-MS121 / SY-MS121-AP Specifications General HDMI Resolutions 720i, 720p, 1080i, 1080p – See above for complete details VGA Resolutions VGA, SVGA, XGA, SXGA, WXGA – See above for complete details Analogue Video Resolutions 525 lines, 625 lines, 720i, 720p – See above for complete details HDMI Standard HDMI 1.3 with HDCP HDBaseT Link Mode HDBaseT, synchronous switching RS232 Supports Tx and Rx only – 9600, 8 data bits, no parity, 1 stop bit Power Supply 110V to 240V AC, 50 / 60 Hz Power Consumption 32 W max Environmental Operating Temperature 0 – 40 °C non condensing Physical Dimensions (W x H x D) 483 x 44 x 235 mm (including flanges) – 19 in 1U rack mount Weight 2.1 kg RS-45 Wiring Both connectors must be wired identically. Figure 7 - RJ45 Wiring HDBaseT will not pass through any Ethernet device. Please do make sure that the Cat6 cable uses 4 pairs of 23AWG solid copper wires. Do not use inferior copper clad cables as these exhibit high resistances. www.sy.co.uk SY-MS121 / SY-MS121-AP Safety Instructions To ensure reliable operation of these products as well as protecting the safety of any person using or handling these devices while powered, please observe the following instructions. 1. Use the power supplies provided. If an alternate supply is required, check Voltage, polarity and that it has sufficient power to supply the device it is connected to. 2. Do not operate this product outside the specified temperature and humidity range given in the above specifications. 3. Ensure there is adequate ventilation, to ensure efficient operation of the equipment. 4. Repair of the equipment should only be carried out by qualified professionals as this product contains sensitive devices that may be damaged by any mistreatment. 5. Only use this product in a dry environment. Do not allow any liquids or harmful chemicals to come into contact with this product. After Sales Service 1. Should you experience any problems while using these products, firstly refer to the Troubleshooting section in this manual before contacting SY Technical Support. 2. When calling SY Technical Support, the following information should be provided:    Product name and model number Product serial number Details of the fault and any conditions under which the fault occurs. 3. These products have a two year standard warranty, beginning from the date of purchase as stated on the sales invoice. Online registration of these products is required to activate the full three year extended warranty. For full details please refer to our Terms and Conditions. 4. SY Product warranty is automatically void under any of the following conditions:     5. The product is already outside of its warranty period Damage to the product due to incorrect usage or storage Damage caused by unauthorised repairs Damage caused by mistreatment of the product Please direct any questions or problems you may have to your local dealer before contacting SY Electronics. www.sy.co.uk