Transcript
Sync LED
Project Name Spec Type
Wall
Notes
Direct/Indirect 3500K, 2400 lm
Order Guide
Some combinations of product options may not be available. Consult factory for assistance with your specification.
7408
LB
G
QN
–
–
–
–
E
–
Product Series & Type
Source & Color
Lumen Package
Optics
Run Length
Wiring
Voltage
Finish
Direct/Indirect
LB 3500K
G 2400 lm*
QN MesoOptics Lens
04 4ft 08 8ft
1 1cct 3 1cct w/emergency wiring 7 1cct dimming (0-10V)
1 120V 2 277V
W White T Titanium Silver B Black C Custom Color
Consult website for complete list of available wiring options
E = Standard Driver See reverse for details.
*4ft nominal
Upgrades
Please indicate with check mark.
6"
1 3/16"
6 1/16"
Sculpted EndCap Sculpted 1/16"
6 1/16"
1 9/16"
5 Year Total System Warranty
Flat
Sync LED comes with a 5 year total system warranty, that covers the entire luminaire—including the LED board, driver and all fixture components—with world class support backed by Philips Ledalite.
Note: Some combinations of product options may not be available. © 2013 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
LED Product Partner
Filename 7408LBGQN.pdf 03 13
Photometry
Sync LED
MesoOptics Lens
Report No. ITL75743 Efficacy 84.5 lm/W Total Lumens 2222 lm
CRI R9 Input Watts
Power Factor 0.94 @ 120 Peak/Zenith Ratio N/A:1 Peak Candela Value N/A @ N/A
83 21 26.3
Wall - Direct/Indirect - 3500K, 2400 lm
Meets RP-1-04 recommendations for VDT-Intensive spaces *IESNA LM-79-08 specifies the entire luminaire as the source resulting in a fixture efficiency of 100%.
Candela Distribution
180 135
Vertical Angle
135
90
90 700 cd
45
45 90-90 45-135 0-180
0
55% Up / 45% Down Fixture photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08. Lumen maintenance of the LEDs used in this fixture has been tested by the LED manufacturer in accordance with IESNA LM-80-08 IES files for this and other photometric options can be downloaded online at ledalite.com
Additional Information Modules
1 3/16"
6 1/16"
Mount Spacing* 4' 0" 8' 0"
45
90
135
180
0 5 15 25 35 45 55 65 75 85 90 95
403 463 570 628 493 300 188 108 42 8 0 20
403 444 517 554 470 301 181 101 42 9 0 35
403 403 399 380 331 246 159 93 38 7 0 23
403 367 316 261 205 155 117 79 37 9 1 34
403 350 286 225 173 132 105 77 36 9 4 44
105 115 125 135 145 155 165 175 180
338 496 531 457 366 312 281 253 237
268 384 395 349 320 298 276 250 237
82 131 163 190 217 236 242 239 237
72 104 125 141 164 189 214 231 237
79 107 122 135 154 174 199 226 237
1/16"
6 1/16"
* Refer to installation instructions for exact mount spacing
Zonal Lumens 39 117 186 209 179 136 91 43 11 48 167 228 225 190 151 112 69 23
Flat
Fax: 800.665.5332
Web: ledalite.com
30
50
0
10
70
50
30
50
30
10
0
106 106 106 106 97 93 89 86 89 82 76 71 81 72 65 60 75 64 57 51 69 57 50 44 63 52 44 38 59 47 39 33 54 42 35 30 51 39 31 26 47 35 28 24
97 89 81 74 68 63 58 54 50 46 43
97 86 75 67 59 53 48 43 39 36 33
97 82 70 61 53 46 41 36 33 29 27
81 72 63 56 50 45 41 37 34 31 28
81 69 60 52 45 40 35 32 28 26 23
81 67 56 48 41 36 31 28 25 22 20
45 39 34 29 25 22 20 18 16 14 13
*Based on a floor reflectance of 0.2
Avg. Luminance (cd/m2) Vertical Angle
Housing 18 gauge cold-rolled steel, precision formed and welded.
Optical System Verge is comprised of arrays of LEDs, edge-lighting a low profile Light Guide panel. The Light Guide panel allows light to be coupled and transmitted through total internal reflection. The microstructured surface of the panel optimizes the light extraction to create a direct indirect distribution. Light is purified and controlled by MesoOptics film as it passes through the non-glare acrylic lens. Standard distribution is 60% up/40% down.
Electrical Factory pre-wired to section ends with quick-wire connectors. Phone: 604.888.6811
0 1 2 3 4 5 6 7 8 9 10
70
80 50
55 65 75 85
Horizontal Angle 0
90
180
4013 3078 1887 913
3503 2778 1849 1001
2241 2195 1617 1028
Spacing Criteria 1.59 @ 0° 1.31 @ 90° 0.77 @ 180°
Due to continuing product improvements, Philips Ledalite reserves the right to change specifications without notice.
Lumen Maintenance At an ambient operating temperature of 25°C, the LED lumen maintenance expectation is L80 > 60,000h.
© 2013 Philips Ledalite
Ceiling:
RCR Wall: 70
Weight Maximum 2.5 lb/ft. Sculpted
Module 4ft 8ft
0
Specifications Endcaps
Module length excludes endcaps. Nominal mount spacing for individually mounted modules.
Coefficients of Utilization (%)
Horizontal Angle
Mounting Fixture is mounted flush to wall using hidden wall brackets. Brackets attach to existing structure, variable within 2”-5” of end or joint. Endcaps Endcaps are diecast aluminum; available in flat (standard) or sculpted (optional). Driver Dimming: 0-10V - 5-100%. Output is Class 2 rated. Approvals Certified to UL, CSA and IES standards. Finish Standard finish is textured matte White, Black or Titanium Silver. Environment Rated for dry or damp locations in operating ambient temperatures of 0-40°C (32-104°F).
Filename 7408LBGQN.pdf 03 13