Transcript
System-95
IF Inputs 3
Ultra-Wideband (up to 1 GHz BW) IF Signal Recording & Playback The System-95 includes DTA-9500 ultra-wideband digital IF transceiver and DTA-1000 (1U) or DTA-5000 (2U) RAID server for recording and playback of one or two ultra-wideband IF signals. The system occupies only 2U rack space for handling 1 IF signal with bandwidths up to 500 MHz. For 2 IF inputs with bandwidths up to 500 MHz each or 1 IF input with bandwidth up to 1 GHz, the System-95 occupies only 3U rack space. All configurations are available with an optional analog IF output. The system is supplied with GUI software which simplifies control and operation. No user development is required for record and playback. System-95 is currently offered in three different configurations System-95L (2U size) for recording 1 IF signal with bandwidths up to 500 MHz (standard IFs are 160 MHz for 100 MHz BW and 1 GHz or 1.2 GHz for 500 MHz BW). This system uses DTA-1000R (1U) RAID server with 8 TB SSD and a maximum throughput rate of 2 GBytes/s (over 1 hour recording at full 500 MHz BW). One analog IF output for any of the above IFs & BWs is optional System-95H (3U size) for recording 2 IF signals with bandwidths up to 500 MHz (standard IFs are 160 MHz for 100 MHz BW and 1 GHz or 1.2 GHz for 500 MHz BW). This system uses DTA-5000 (2U) RAID server with 24 TB SSD and a maximum throughput rate of 4 GBytes/s. Optionally this configuration also offers 1 GHz BW IF signal recording for 1.2 GHz, 1.5 GHz or 3 GHz IF for over 5 hours. For this option an IF down coversion stage is included for IF down conversion to 900 MHz IF. One analog IF output for any of the above IFs & BWs is optional System-95P is a portable verion. Multiple System-95 units can be operated synchronously to increase channel count. Contact factory for rugged airborne, shipboard & ground-mobile applications.
Applications • • • •
ELINT signal recording & playback EW simulation Radar signals library creation Simultaneous record & playback from data drives option simplifies wideband communication and radar system development
IF Out
1 2
DTA-9500
3U DTA-5000 RAID Server (12 or 24 TB SSD Storage) Typical System-95H configuration includes DTA-9500 ultra-wideband digital IF transceiver (1U) and DTA-5000 RAID server (2U) for long duration recording & playback.
Key Features • Compact size & low-cost
• Multiple IF & BW options: • 2 IF inputs at 160 MHz with BWs up to 100 MHz, or • 2 IF inputs at 1 or 1.2 GHz with BWs up to 500 MHz, or • 1 IF input at 1.2, 1.5 or 3 GHz with BWs up to 1 GHz • 1 optional IF output for any of the above IF and BW • 12-bit data converters & 12- or 16- IQ data recording & playback • 4 x 10 GbE optical networks for data and a separate 1 GbE optical network for control support remote opertion • DTA-5000 RAID server with up to 24 TB SSD storage • Up to 4 GBytes/s record/playback rate & up to 24 TB SSD storage • GUI software for convenient control & operation • Multiple System-95 units can be operated synchronously • Tunable RF input & output are also offered • Rugged version also offered (contact factory) IF In # 3 IF In # 1 IF In # 2 (BW=1 MHz) (BW<=500 MHz) (BW <=500 MHz)
Optional IF Down Conversion, Filtering & Gain
DTA-9500
IF Filter & Gain
IF Filter & Gain
ADC [12-Bit]
ADC [12-Bit]
IF Filter & Gain
DAC [12-Bit]
2 X Virtex 6 FPGAs 4 x 10 GbE Fibers DTA-5000 [RAID Server With Up To 24 TB SSDs] Up To 4 Gbytes/s Throughput Rate
IF OUT Option
Specifications
IF Output
IF Input 2 ADCs for Fs <= 1.8 GSPS 1 ADC for Fs > 1.8 GSPS
1 DAC Output
Maximum Sample/ Update Rate
3.6 GSPS
4 GSPS
Data Converter Precision
12 Bit
12 Bit
No of ADC/DAC channels
0 dB
0 dB
Input/Output Impedance
50 Ohm
50 Ohm
Connector
50 Ohm SMA Female
SFDR
<-60 dBc
<-55 dBc
Integrated SNR
58 dB
50 dB
Noise Figure
7 dB
Gain
18 dB
7 dB
Gain Control
31.75 dB in .25 dB Steps
Same
OIP3
35 dBm
35 dBm
Reference Clock
100 MHz (Internal TCXO) 10 - 100 MHz (External)
TCXO Phase Noise
<-100 dBC/Hz @ 100 Hz
External Reference Level
Sine +6 dBm (max)
DDC/DUC Arithmetic Precision
IF In [Up to 500 MHz BW]
50 Ohm SMA Female
Same
Same
2, 3, 4 & 6 (contact factory for other options) Full Precision
IF Out [Optional]
Storage Temp
-20 to 700 C
Warm up time
5 minutes 95% non-condensing
Size
1U x 19”x20” (DTA-9500) 2U x 19”x24” (DTA-5000)
weight
15 Lbs (DTA-9500) 50 Lbs (DTA-5000)
Power (Max)
400 W (Total)
Note: System-95L uses DTA-1000R (1U) RAID Server with 8TB SSDs: Power (Max) 250W
2, 3, 4 & 6 (contact factory for other options)
DUC Interpolation
0 to 400 C
Physical (95H)
2 X Virtex 6
DDC Decimation
Operating Temp
Humidity
Full Scale Input/Output
Data FPGA
Environmental
RAID Server
Parameter
Max Data Rate to Recorder / Player
4 GBytes/s
Data Network
4 x 10 Gigabit networks
Control Network
1 Gigabit
Processors
1 x Quad Core Xeon
Storage (Hard Drives)
Up to 24 x 1 TB (SSD)
General Documentation (Post-Sales)
Quick Start Guide
Warranty
1 Year
Tablet
2x10 GbE (I Q Data)
DTA-950 [Digital IF Transceiver]
DTA-590 [Recorder / Player, 6 TB SSDs]
System-95P: Portable Version This option currently supports single channel 500 MHz BW recording with IF at either 1 GHz or 1.2 GHz. The ADC is 12-bit, however, the output of the DDC is rounded to 8 bits for both I & Q data for recording.
Carrying Case
Download Presentation on Systems-95 from D-TA’s homepage www.d-ta.com
[email protected]
1-877-382-3222