Preview only show first 10 pages with watermark. For full document please download

Sysvrf - Reftec

   EMBED


Share

Transcript

30 | VRF systems SYSVRF VRF systems | SYSVRF multi-zone solutions: light commercial and commercial VRF systems The SYSVRF modular systems are most valuable for room space from 100 to 1000 sq.m. with large independence of climatic zones - hotels, restaurants, retail, office buildings, etc. Up to 4 modular outdoor units can be combined in one single refrigerant system thus reaching up to 200kW of cooling capacity and connecting up to 64 indoor units. In the same system they are able to fulfill the increasing demands of air comfort still having low operating costs. All SYSVRF systems are equipped with DC Inverter compressors and DC Inverter fans which gives enhanced system performance and very low operating noise. The new generation of 3-pipe systems are equipped with all DC Inverter compressor which delivers outstanding comfort pleasure and reduces tremendously the electricity consumption. SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor units or the superior Modular heat recovery 3-pipe units. SYSVRF Mini and SYSVRF Modular systems SYSVRF AIR EVO HP Mini 34 SYSVRF DUCT 54 SYSVRF AIR EVO HP 36 SYSVRF DUCT HP 56 SYSVRF AIR EVO HR 40 SYSVRF HRV 58 SYSVRF WALL 46 SYSCONTROL AHU 60 SYSVRF CASSETTE MINI 48 SYSVRF selection software 61 SYSVRF CASSETTE 50 SYSCONTROL systems 62 SYSVRF CEILING 52 SYSVRF JOINT accessories 64 31 32 | VRF systems VRF Systemair- SYSVRF Multi-zone air conditioning system 95)V\VWHPVDUHPRVWEHQHʾFLDOIRUVSDFHXSWR 2000 sq.m. with large independence of climatic zones – KRWHOVUHVWDXUDQWVUHWDLOVSDFHRIʾFHEXLOGLQJVHWF ,QWKHVDPHV\VWHPWKH\DUHDEOHWRIXOʾOOWKHLQFUHDVLQJ demands of the parameters of air in each room and still have low operating costs. The most comfortable temperature An important advantage of the multi-zone air-conditioning is a smooth and rapid achievement of a comfortable WHPSHUDWXUHDVZHOODVPDLQWDLQLQJWKHVSHFLʾHG parameters accurate to ± 0,5 °C. Such high performance was achieved thanks to an accurate control of the UHIULJHUDQWʿRZDQGWKHPHFKDQLVPRIUHGLVWULEXWLRQRI refrigerant between the several units, implemented with the help of electronic expansion valves. +LJKHQHUJ\HIʾFLHQF\ 7KHHIʾFLHQF\RIPXOWL]RQHV\VWHPVLVYHU\KLJKEHFDXVH each time the electric power is consumed as much as necessary to carry out user requirements. If the indoor units work only in a few areas of the building, then the power consumption is reduced proportionally by FKDQJLQJWKHUHIULJHUDQWʿRZ Low noise Low noise of both outdoor and indoor units makes the job a multizone system virtually inconspicuous. A balanced lineup The lineup of multizone VRF series are continuously optimized. In response to market demands Systemair offers several types and sizes of indoor units: wallPRXQWHGFDVVHWWHʿRRUFHLOLQJDQGGXFW Outdoor units Mini, despite the compact dimensions , solve different tasks of air conditioning on small objects. Six modular outdoor units can be combined in one refrigerant system thus reaching a total cooling capacity of up to 200 kW. Separately, to highlight the 3 Pipe heat recovery system for indipendent and simultaneous cooling and heating operation. &RQWLQXRXVGHYHORSPHQWLQWKHʾHOGRIPDQDJHPHQW In modern air-conditioning systems the demand for automation and control systems integrated with other infrastructure building systems is continuously increasing. These are exactly the principles on the basic of the development of the control systems of Systemair. In addition to the traditional control systems of air conditioning, the user deals with different possibilities of control that can solve the various needs of the building management such as the possibility of control via personal computer and Internet network connection. Simplicity of design Systemair provides full integration and coordination of DOOHOHPHQWVRIDPXOWL]RQHV\VWHPJUHDWO\VLPSOLʾHV the task of the designer. The selection process can be performed in maximum short period of time by using a simple and complete selection and designing software. VRF systems | SYSVRF lineup In 2014 Systemair has launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the high standards set by the industry. 7KURXJKWKHXVHRIPRGHUQWHFKQRORJLHVDQGLPSOHPHQWDWLRQRIWKHLURZQGHYHORSPHQWKDVVLJQLʾFDQWO\LPSURYHGHQHUJ\ HIʾFLHQF\ DQG GHFUHDVHG WKH QRLVH OHYHO ZLWK FRPSDFW GLPHQVLRQV LQFUHDVHG HDVH RI LQVWDOODWLRQ DQG PDLQWHQDQFH greatly expanded the range of application from light commercial to large commercial spaces. SYSVRF outdoor units SYSVRF mini 2 Pipe Heat Pump 12,0-16,0 kW SYSVRF modular 3 Pipe Heat Recovery 25,0-180,0 kW SYSVRF modular 2 Pipe Heat Pump 25,0 - 200,0 kW SYSVRF WALL SYSVRF CEILING SYSVRF Indoor units 1,5-5,6 kW SYSVRF CASSETTE MINI 2,2-5,6 kW SYSVRF DUCT 2,2-14,0 kW SYSVRF HRV 500-2.000 m /h 3 3,6-14,0 kW SYSVRF CASSETTE 2,8-14,0 kW SYSVRF DUCT HP 7,1-28,0 kW SYSCONTROL AHU 7,0-73 kW Compatible outdoor and indoor series Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor units. There are 6 different types of indoor units available with capacity from 1,5 kW to 28,0 kW, making the total number of indoor units equal to 40 different types and capacities. The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air handling unit with the control module SYSCONTROL AHU. 33 | Mini VRF Mini VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP Features Full DC Inverter Mini VRF with DC Inverter compressor and DC fan motor. Compact size and long piping system. High efficiency at partial load. Inverter Rotary compressor providing wide capacity output from 10% to 100% evenly. Centralized control, BMS connection and web access potential. Hydrophilic Blue Fin coil enhances durability and protection against corrosion. Piping connection in four different directions makes simple the installation of outdoor unit. Maximum 7 indoor units connection. Indoor unit combination total capacity index from 45% to 130%. H Dimensions A F E D B C 34 Model 120 140 160 A 900 900 900 B 600 600 600 C 348 348 348 D 320 320 320 E 400 400 400 F 360 360 360 H 1.327 1.327 1.327 Mini VRF | Technical features Model Indoor unit SYSVRF 120 AIR EVO HP Q 140 AIR EVO HP R 160 AIR EVO HP R 314089 314092 314094 Art. no. Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 Cooling capacity kW 12,3 14,0 15,5 Power Input kW 3,25 3,95 4,52 3,78 3,54 3,43 Heating capacity kW 13,2 15,4 17,0 Power Input kW EER COP Max. current Compressor Inverter Rotary A Quantity 4,77 3,56 36 12 1 Power Input W 3.010 3.010 4.240 Refrigerant oil ml 870+630 870+630 1.400+250 m3/h Sound pressure level 6.000 dB(A) 57 Type R410A Refrigerant charge kg Dimension LxWxH mm Packing LxWxH mm Net/gross weight Piping dimension 4,16 3,70 pcs $LUʿRZ Refrigerant 3,47 3,80 3,3 mm (in) Gas pipe mm (in) Max qty. indoor units connection pcs Operating ambient temp. range °C 3,9 1.030x435x1.456 kg Liquid pipe 3,9 900x320x1.327 95/106 95/106 102/113 9,5 (3/8”) 15,9 (5/8”) 6 6 7 Cooling -15 ... +48 / Heating -15 ... +27 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. 0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW branch) equivalent lenght. 100 m Maximum outdoor unit-indoor unit drop height. 30 m Maximum indoor unit to indoor unit drop height. 20 m Outdoor units SYSVRF AIR EVO HP Permitted value Total piping lenght (actual) Piping lenght Maximum piping 100 m Actual lenght 60 m Aquivavent lenght 70 m 3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK  equivalent lenght Drop height 8m Outdoor unit-indoor unit drop height Indoor unit to indoor unit drop height 20 m Outdoor unit up 30 m Outdoor unit down 20 m 8m 35 | VRF Heat Pump Modular VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP SYSVRF 252-280 AIR EVO HP R Features Wide application area due to incredible piping lenght and wide operating temperature range. Free modular combination of 6 basic units, up to a total capacity of maximum 200 kW. Top class energy efficiency. DC Inverter Scroll compressor provinding wide capacity output from 10% to 100% evenly. DC Inverter fan motor. High performance of the new designed heat exchanger. External static pressure up to 60 Pa (factory option, 20 Pa standard). Maximum 64 indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. SYSVRF 335-400-450 AIR EVO HP R SYSVRF 500 AIR EVO HP R Dimensions SYSVRF 252/280 AIR EVO HP R SYSVRF 335/400/450/500 AIR EVO HP R 1615 1615 1250 765 960 765 36 VRF Heat Pump | Technical features Model Indoor unit SYSVRF Art. no. Power Supply 252 AIR EVO HP R 280 AIR EVO HP R 335 AIR EVO HP R 400 AIR EVO HP R 450 AIR EVO HP R 500 AIR EVO HP R 314078 314079 314080 314081 314082 314083 V/Ph/Hz 380-415/3/50 Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 50,0 Power Input kW 5,88 7,20 9,05 12,31 14,02 15,20 EER 4,29 3,89 3,7 3,25 3,21 3,29 Heating capacity kW 27,0 31,5 37,5 45,0 50,0 56,0 Power Input kW 6,15 7,61 8,99 11,19 12,79 14,25 4,39 4,14 4,17 4,02 3,91 3,93 20,8 22,1 23,7 31,8 32,8 35,4 COP Max. current Compressor Inverter Scroll Compressor Fixed Scroll A Quantity pcs Capacity W 31.590 31.590 11.800 31.590 31.590 31.590 Refrigerant oil ml 500 500 500 500 500 500 Quantity pcs - - 1 1 1 1 Capacity W - - 17.100 13.390 13.390 20.900 ml - Refrigerant oil $LUʿRZ Sound pressure level Refrigerant 1 500 500 500 500 m3/h 11.500 - 15.100 15.600 15.600 15.600 dB(A) 57 59 Type Refrigerant charge kg 9 Dimension (LxWxH) mm 960x765x1.615 Packing (LxWxH) mm 1.025x830x1.790 Net/gross weight kg Piping dimension 60 61 13 16 R410A 11 1.250x765x1.615 1.305x825x1.790 198/213 266/288 280/300 300/320 Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 19,1 (3/4”) Gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Oil balance pipe mm (in) Operating ambient temp. range 6,35 (1/4”) °C Cooling -5 ... +48 / Heating -20 ... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. 0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 2000 AIR EVO HP R Permitted value Total piping lenght (actual) Piping lenght Maximum piping 1.000 m Actual lenght 175 m Aquivavent lenght 200 m 3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK  equivalent lenght Drop height Outdoor unit-indoor unit drop height Outdoor unit down Outdoor unit up Indoor unit to indoor unit drop height :KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO ** Level difference: less or equal to 50m is standard; more than 50m is available to be customized. 40 m/90 m* 110 m 50 m/70 m** 30 m 37 38 | VRF Heat Pump combination Outdoor unit combination SYSVRF AIR EVO HP Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HP R SYSVRF 252 AIR EVO HP R - 13 28/31,5 SYSVRF 280 AIR EVO HP R SYSVRF 280 AIR EVO HP R - 16 33,5/37,5 SYSVRF 335 AIR EVO HP R SYSVRF 335 AIR EVO HP R - 20 40/45 SYSVRF 400 AIR EVO HP R SYSVRF 400 AIR EVO HP R - 23 45/50 SYSVRF 450 AIR EVO HP R SYSVRF 450 AIR EVO HP R - 26 50/56 SYSVRF 500 AIR EVO HP R SYSVRF 500 AIR EVO HP R - 29 56/63 SYSVRF 560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 SYSVRF JOINT OUT 02 HP 33 61,5/69 SYSVRF 615 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 335 AIR EVO HP R SYSVRF JOINT OUT 02 HP 36 68/76,5 SYSVRF 680 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R SYSVRF JOINT OUT 02 HP 39 73/81,5 SYSVRF 730 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 02 HP 43 78/87,5 SYSVRF 780 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 46 85/95 SYSVRF 850 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 02 HP 50 90/101 SYSVRF 900 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 53 95/106 SYSVRF 950 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 56 100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 02 HP 59 VRF Heat Pump combination | Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 106/119 SYSVRF 1060 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 63 113/126,5 SYSVRF 1130 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 120/135 SYSVRF 1200 AIR EVO HP R SYSVRF 400 AIR EVO HP R x3 SYSVRF JOINT OUT 03 HP 64 123/137,5 SYSVRF 1230 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 128/143,5 SYSVRF 1280 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 135/151 SYSVRF 1350 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 140/157 SYSVRF 1400 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 145/162 SYSVRF 1450 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 150/168 SYSVRF 1500 AIR EVO HP R SYSVRF 500 AIR EVO HP R x3 SYSVRF JOINT OUT 03 HP 64 156/175 SYSVRF 1560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 04 HP 64 163/182,5 SYSVRF 1630 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 04 HP 64 168/188,5 SYSVRF 1680 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 173/193,5 SYSVRF 1730 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 178/199,5 SYSVRF 1780 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 185/207 SYSVRF 1850 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 190/213 SYSVRF 1900 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 195/218 SYSVRF 1950 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 200/224 SYSVRF 2000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x 4 SYSVRF JOINT OUT 04 HP 64 39 | VRF Heat Recovery Modular VRF Heat Recovery Outdoor Units SYSVRF AIR EVO HR Features Simultaneous operation in cooling and heating mode provides more comfort and reduces power consumption. Wide application area due to incredible piping lenght and wide operating temperature range. Free modular combination of 5 basic units, up to a total capacity of maximum 180 kW. Top class energy efficiency. All DC Inverter Scroll compressors providing wide capacity output from 10% to 100% evenly. DC fan motor. High performance of the new designed heat exchanger with double refrigerant circuit. External static pressure up to 40 Pa (20 Pa standard). Maximum 64 indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. Continous heating output during defrost operation thanks to the innovative double heat exchanger. Dimensions SYSVRF 252/280/335/400/450 AIR EVO HR R 765 1250 1615 40 VRF Heat Recovery | Technical features Model Indoor unit SYSVRF Art. no. Power Supply 252 AIR EVO HR R 280 AIR EVO HR R 335 AIR EVO HR R 400 AIR EVO HR R 450 AIR EVO HR R 314084 314085 314086 314087 314088 V/Ph/Hz 380-415/3/50, 380-415/3/60 Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 Power Input kW 5,73 6,67 8,07 11,30 13,24 3,40 EER 4,40 4,20 4,15 3,54 Heating capacity kW 27,0 31,5 37,5 45,0 50,0 Power Input kW 6,00 7,33 8,72 11,19 12,79 4,50 4,30 4,30 4,02 3,91 20,8 22,1 22,8 31,8 32,8 2 2 COP Max. current Compressor Inverter Scroll A Quantity pcs 1 1 1 Capacity W 31.590 31.590 31.590 Refrigerant oil Sound pressure level Refrigerant ml m3/h $LUʿRZ 31.590+11.800 500 500 500 12.000 12.000 13.000 15.000 15.000 58 60 60 dB(A) 57 Type 500+500 R410A Refrigerant charge kg 10 10 10 14 Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615 Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790 Net/gross weight kg Piping dimension 255/273 303/322 Liquid pipe mm (in) 9,5 (3/8”) 12,7 (1/2”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) Low pressure gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”) 28,6 (1 1/8”) High pressure gas pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) Oil balance pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Gas balance pipe mm (in) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 7,5 m 0m Heating mode 20°C DB, 15°C WB 7°C 7,5 m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. 0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 1800 AIR EVO HR R Permitted value Total piping lenght (actual) Piping lenght Maximum piping 1.000 m Actual lenght 175 m Aquivavent lenght 200 m 3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK  equivalent lenght Drop height Outdoor unit-indoor unit drop height Outdoor unit up Outdoor unit down Indoor unit to indoor unit drop height :KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO ** Level difference: less or equal to 50m is standard; more than 50m is available to be customized. 40 m/90 m* 110 m 50 m/70 m** 30 m 41 42 | VRF Heat Recovery switch module Mode Switch module for VRF Heat Recovery systems SYSVRF BOX HR Features SYSVRF BOX 02 HR Simultaneous heating and cooling in a single refrigerant system thanks to the combination of SYSVRF HR outdoor units and the SYSVRF BOX modules. SYSVRF BOX HR is available in 3 different modules with 2, 4 or 6 outlets and combination up to 24 indoor units from a single module. SYSVRF BOX 02-1 HR and 04-1 HR can connect only  RQHLQGRRUXQLWDQGWKH\DUHVSHFLʾFDOO\GHVLJQHGIRU the combination with SYSCONTROL AHU and Systemair air handling units. Compact and light design, it can be installed in narrow space. Heating Heating Heating SYSVRF BOX 06 HR SYSVRF BOX 04 HR Independent sub-cooling circuit for each SYSVRF BOX HR module. Off Cooling Cooling Dimensions SYSVRF BOX SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR A 630 960 960 B 600 600 600 C 225 225 225 D 490 820 820 E 300 300 300 VRF Heat Recovery switch module | Technical features SYSVRF BOX 02 HR Model Art. no. 314161 Power Supply V/Ph/Hz SYSVRF BOX 04 HR SYSVRF BOX 06 HR 314162 314186 220-240/1/50 Max indoor unit groups 2 4 6 Max number of each group indoor units 4 4 4 4x6=24 4x2=8 4x4=16 Max capacity of each group indoor units Max number of all downstream indoor units kW 16 16 16 Total capacity of all downstream indoor units kW    15,9 (5/8”) Connect to outdoor unit Piping connections Connect to indoor unit Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) High pressureg gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 35/44,5 SYSVRF BOX 02-1 HR Model Art. no. 313550 Power Supply V/Ph/Hz Max number of indoor unit Max capacity of indoor unit Piping connections SYSVRF BOX 04-1 HR Connect to outdoor unit Connect to indoor unit kW 313551 220-240/1/50 1 1 20-28 40-56 15,9 (5/8”) Liquid pipe mm (in) 12,7 (1/2”) High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (5/8”) Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) Dimension (LxWxH) mm 630x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 Piping connections SYSVRF BOX Outdoor unit Indoor unit SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR Liquid pipe 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) High pressure pipe 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Low pressure pipe 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Liquid pipe 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) Gas pipe 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 43 44 | VRF Heat Recovery combination Outdoor unit combination SYSVRF AIR EVO HR Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HR R SYSVRF 252 AIR EVO HR R - 13 28/31,5 SYSVRF 280 AIR EVO HR R SYSVRF 280 AIR EVO HR R - 16 33,5/37,5 SYSVRF 335 AIR EVO HR R SYSVRF 335 AIR EVO HR R - 20 40/45 SYSVRF 400 AIR EVO HR R SYSVRF 400 AIR EVO HR R - 23 45/50 SYSVRF 450 AIR EVO HR R SYSVRF 450 AIR EVO HR R - 26 53,2/58,5 SYSVRF 532 AIR EVO HR R SYSVRF 252 AIR EVO HR R + SYSVRF 280 AIR EVO HR R SYSVRF JOINT OUT 02 HR 29 56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 33 61,5/69 SYSVRF 615 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R SYSVRF JOINT OUT 02 HR 36 68/76,5 SYSVRF 680 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R SYSVRF JOINT OUT 02 HR 39 73/81,5 SYSVRF 730 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 02 HR 43 80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 46 85/95 SYSVRF 850 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 02 HR 50 90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 53 VRF Heat Recovery combination | Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 96/108 SYSVRF 960 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 400 AIR EVO HR R SYSVRF JOINT OUT 03 HR 56 101/113 SYSVRF 1010 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 59 106,5/119 SYSVRF 1065 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 63 113/126,5 SYSVRF 1130 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 64 120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 SYSVRF JOINT OUT 03 HR 64 125/140 SYSVRF 1250 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 64 130/145 SYSVRF 1300 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 03 HR 64 135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 SYSVRF JOINT OUT 03 HR 64 143,2/158,5 SYSVRF 1432 AIR EVO HR R SYSVRF 252 AIR EVO HR R+ SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 146/163 SYSVRF 1460 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 151,5/169 SYSVRF 1515 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 158/176,5 SYSVRF 1580 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 165/185 SYSVRF 1650 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 04 HR 64 170/190 SYSVRF 1700 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 175/195 SYSVRF 1750 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x3 SYSVRF JOINT OUT 04 HR 64 180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 SYSVRF JOINT OUT 04 HR 64 45 | VRF Wall indoor units Wall-Mounted Indoor Units SYSVRF WALL Features  )URQWSDQHORIPRGHUQGHVLJQWKDWʾWVLQWRDQ\ interior decor. Even and smooth air distribution due to auto swing function. Multi-refrigerant outlet pipe method: left/right/rear, more flexible for installation. Washable air filter, easy for insertion and removal. Built-in electronic expansion valve (EXV) ensuring  SUHFLVHʿRZFRQWURO Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions B 46 A C Indoor unit SYSVRF WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q A mm 915 1.072 B mm 290 315 C mm 230 230 VRF Wall indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q 314123 314124 314125 314126 314127 314128 V/Ph/Hz Cooling capacity kW Power Input 220-240/1/50 1,5 2,2 2,8 W Current A Heating capacity kW Power Input A m3/h $LUʿRZ KLPHGORZ Sound pressure level (hi/med/low) 4,5 5,6 45 0,14 1,7 0,20 2,4 3,2 W Current 3,6 28 4,0 0,33 5,0 6,3 28 45 0,14 0,20 525/480/430 590/520/480 860/755/830 925/860/755 35/32/29 40/38/34 Dimension (LxWxH) dB(A) mm 915x230x290 1.072x230x315 Packing (LxWxH) mm 1.020x315x390 1.180x315x415 Net/gross weight kg 13/16,5 15,1/18,8 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 16,5 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 47 | VRF Compact Cassette indoor units Compact Cassette Indoor Units SYSVRF CASSETTE MINI Features New grille SYSPANEL CASSETTE MINI VRF with 360°  DLUGLVFKDUJHSURYLGLQJVWURQJFLUFXODWLQJDLUʿRZ to cool or heat every corner of the room. Compact casing making it match perfectly with ambient decoration. Advanced 3D spiral fan design reducing the air resistance and operation noise. Integrated drain pump with a head of 500 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring  SUHFLVHʿRZFRQWURO Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 90 (optional) Wired controller SYSCONTROL WC 120 (optional) Dimensions Connecting points of refrigerant pipe (gas/liquid side) Drain point Hook Main body 260 647 (panel) 570 523 60 48 Nut 50 545 570 647 (panel) Ceiling 600 Panel VRF Compact Cassette indoor units | Technical features SYSVRF CASSETTE MINI 22 Q CASSETTE MINI 28 Q CASSETTE MINI 36 Q CASSETTE MINI 45 Q CASSETTE MINI 56 Q SYSPANEL CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF Art. no. Indoor unit 314095 314096 314097 314098 314099 Art. no. Panel unit 313324 313324 313324 313324 313324 4,5 5,6 Model Indoor unit Model Panel unit Power Supply V/Ph/Hz Cooling capacity Power Input Current 2,2 2,8 W 48 48 kW Power Input W Current A $LUʿRZ KLPHGORZ Sound pressure level (hi/med/low) Panel kW A Heating capacity Unit 220-240/1/50 3,6 56 0,175 2,4 0,21 3,2 4,0 0,175 0,21 m3/h 522/414/313 610/521/409 dB(A) 35,8/33,4/23,4 Dimension (LxWxH) mm Packing (LxWxH) mm Net/gross weight kg 6,0 56 41,5/35,6/28,8 570x570x260 675x675x285 17,5/22 19/23,5 Dimension (LxWxH) mm 647x675x50 Packing (LxWxH) mm 705x705x113 Net/gross weight kg 3/5 Refrigerant Piping dimension 5,0 48 R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3,8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 25 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 49 | VRF Cassette indoor units Standard Cassette Indoor Units SYSVRF CASSETTE Features New grille SYSPANEL CASSETTE EVO with 360° air  GLVFKDUJHSURYLGLQJVWURQJFLUFXODWLQJDLUʿRZWRFRRO or heat every corner of the room. Ultra-thin casing for easy installation into a shallow ceiling. Advanced 3D spiral fan design reducing the air resistance and operation noise. Integrated drain pump with a head of 750 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring  SUHFLVHʿRZFRQWURO Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions 950 780 105 Φ32 Drain pipe outter diameter A 70 ≥20 146 840 55 950 680 50 Ceiling B CASSETTE 28 Q Indoor unit SYSVRF 840 904 Φ75 New air supply orifice CASSETTE 36 Q CASSETTE 45 Q CASSETTE 56 Q CASSETTE 71 Q 46 Panel Main body CASSETTE 90 Q CASSETTE 112 Q A mm 230 230 300 B mm 170 170 190 CASSETTE 140 Q VRF Cassette indoor units | Technical features Model Indoor unit Model Panel unit SYSVRF CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q SYSPANEL CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE EVO EVO EVO EVO EVO EVO EVO EVO Art. no. Indoor unit 314100 314101 313325 314102 314103 314104 314105 314106 Art. no. Panel unit 314034 314034 314034 314034 314034 314034 314034 314034 9,0 11,2 14,0 Power Supply V/Ph/Hz Cooling capacity kW Power Input W Current A Heating capacity kW Power Input W Current A m3/h $LUʿRZ KLPHGORZ Sound pressure level (hi/med/low) Unit Panel 220-240/1/50 2,8 3,6 80 mm Packing (LxWxH) mm Net/gross weight kg 5,6 7,1 90 75 82 160 170 0,50 0,70 0,80 0,40 3,2 4,0 80 5,0 6,3 8,0 90 75 82 160 170 0,50 0,70 0,80 1.157/ 955/749 1.540/1.300/1.120 1.800/ 1.500/ 1.280 45/42/39 48/45/43 50/47/44 0,40 847/766/640 dB(A) Dimension (LxWxH) 4,5 864/755/658 42/38/35 12,5 840x840x230 955x955x247 24/28 15,0 840x840x300 955x955x317 26/30 32/37 Dimension (LxWxH) mm 950x950x46 Packing (LxWxH) mm 1.000x1.000x60 Net/gross weight kg 6/8 Refrigerant Piping dimension 10,0 R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 32 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 51 | VRF Ceiling/Floor indoor units Ceiling and Floor Indoor Units SYSVRF CEILING Features Flexible vertical or horizontal installation, even into a corner of the ceiling. Even and smooth air distribution due to auto horizontal and auto vertical swing function.  :LGHDQJOHDLUʿRZ Low noise operation.  :DVKDEOHDLUʾOWHUHDV\IRULQVHUWLRQDQGUHPRYDO Built-in electronic expansion valve (EXV) ensuring  SUHFLVHʿRZFRQWURO Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Infrared remote control SYSCONTROL RM 02 (standard) Wired controller SYSCONTROL WC 90 (optional) Accessories/option Wired controller SYSCONTROL WC 120 (optional) Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Dimensions SYSVRF CEILING 36/45/56/71 Q SYSVRF CEILING 112/140 Q 995 906,5 35 39,5 401 1670 1542,3 198,2 724,5 371 630,5 235 112,5 144 184,5 255,2 98 133,5 175 69,5 675 655 200 207 SYSVRF CEILING 90 Q 1284,5 1194,5 515 198,2 39,5 37 655 98 133,5 175 547 200 52 VRF Ceiling/Floor indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply CEILING 36 Q CEILING 45 Q CEILING 56 Q 314116 314117 314118 V/Ph/Hz Cooling capacity CEILING 140 Q 314119 314120 314121 314122 11,2 220-240/1/50 3,6 4,5 5,6 7,1 9,0 49 120 122 125 130 A 0,57 0,60 4,0 5,0 6,3 8,0 10,0 W 49 120 122 125 130 182 Current 0,55 14,0 182 kW Power Input A Sound pressure level (hi/med/low) CEILING 112 Q W Current $LUʿRZ KLPHGORZ CEILING 90 Q kW Power Input Heating capacity CEILING 71 Q 0,55 3 m /h 650/ 570/500 dB(A) 40/38/36 0,57 0,83 12,5 15,5 0,60 0,83 800/600/500 1.200/ 900/700 1.980/1.860/1.730 43/41/38 45/43/40 47/45/42 1.670x244x680 Dimension (LxWxH) mm 990x206x660 1.280x 206x660 Packing (LxWxH) mm 1.089x296x744 1.379x 296x744 1.764x329x760 Net/gross weight kg 34,5/41 54/59 26/32 28/34 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 16 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 53 | VRF Duct indoor units Medium Static Pressure Duct Indoor Units SYSVRF DUCT Features External static pressure up to 100 Pa.  :DVKDEOHDLUʾOWHUSODFHGLQDQDOXPLQXPIUDPHZKLFK is removable downward from the bottom.  )UHVKDLUKROHDLULQOHWRXWOHWʿDQJHDUHVWDQGDUGIRU easy duct connection. Air inlet from back as standard and from bottom as  RSWLRQDOZLWKWKHVDPHʿDQJHSODWH Integrated drain pump with a head of 750 mm.  (OHFWURQLFH[SDQVLRQYDOYH (;9 ʾ[HGLQVLGHRIWKH indoor unit. Standard functional port such as remote on/off free contact. Display board with infrared receiver as standard equipment. Wired controller SYSCONTROL WC 90 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (standard) Infrared remote control SYSCONTROL RM 02 (optional) Wired controller SYSCONTROL WC 120 (optional) Accessories/option Infrared controller SYSCONTROL RM 02 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Dimensions Indoor unit SYSVRF DUCT 22 Q DUCT 28 Q DUCT 36 Q DUCT 45 Q DUCT 56 Q mm 700 700 700 920 920 mm 210 210 210 210 210 C mm 635 635 635 635 635 D mm 570 570 570 570 570 B H A B I 54 F G A E D C E mm 65 65 65 65 65 F mm 493 493 493 713 713 G mm 35 35 35 35 35 H mm 119 119 119 119 119 Indoor unit SYSVRF DUCT 71 Q DUCT 90 Q DUCT 112 Q DUCT 140 Q A mm 920 1.140 1.140 1.200 B mm 270 270 270 300 C mm 635 775 775 865 D mm 570 710 710 800 E mm 65 65 65 80 F mm 713 933 933 993 G mm 35 35 35 40 H mm 179 179 179 204 VRF Duct indoor units | Technical features Model Indoor unit DUCT 22 Q DUCT 28 Q DUCT 36 Q DUCT 45 Q 314107 314108 314109 314110 SYSVRF Art. no. Power Supply V/Ph/Hz Cooling capacity kW 2,2 2,8 3,6 W 59 57 61 Current A kW 2,6 3,2 4,0 W 59 57 61 Current A m3/h Sound pressure level (hi/med/low) dB(A) External static pressure DUCT 90 Q DUCT 112 Q DUCT 140 Q 314111 314112 314113 314114 314115 14,0 4,5 5,6 0,28 Power Input $LUʿRZ KLPHGORZ DUCT 71 Q 220-240/1/50 Power Input Heating capacity DUCT 56 Q 7,1 9,0 11,2 92 149 200 313 0,50 0,70 1,00 5,0 8,0 10,0 12,5 92 149 200 313 274 0,28 0,50 0,70 1,16 1,65 1,80 570/410/320 958/667/583 1207/ 905/821 1400/ 1018/ 861 2010/ 1552/ 1389 2030/ 1539/ 1250 43/38,9/36 45/ 40/36 42/ 38/36 40/35/32 6,3 274 1,80 47/ 50/ 39,8/37 41,9/38 20 (10~50) 10 (10~30) Pa 15,5 50/ 43,2/39 40 40 (10~80) (10~100) Dimension (LxWxH) mm ǸǸ ǸǸ Ǹ Ǹ ǸǸ Ǹ Ǹ Packing (LxWxH) mm ǸǸ ǸǸ Ǹ Ǹ ǸǸ Ǹ Ǹ Net/gross weight kg 27/32 30/34 40/48 49/58 21,5/26 22/27 Refrigerant R410A Piping dimension Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping mm Operating ambient temp. range 32 °C Cooling +17…+32 / Heating +10…+28 Fan performance SYSVRF DUCT 22/28/36 Q 80 70 70 70 External static pressure (Pa) 50 Medium speed 30 Low speed 20 10 50 Super high speed 40 External static pressure (Pa) High speed 40 60 60 Super high speed 50 High speed 30 Medium speed 20 Low speed 600 800 800 1000 630 800 1200 SYSVRF DUCT 112 Q 220 200 200 90 180 180 80 160 Low speed 30 20 10 140 External static pressure (Pa) Medium speed 40 High speed 120 100 Medium speed 80 Low speed 60 40 1000 1200 1400 Air flow (m 3/h) Super high speed High speed 120 100 20 770800 1400 160 Super high speed 140 External static pressure (Pa) 50 1200 SYSVRF DUCT 140 Q 100 High speed 1000 Air flow (m 3/h) 220 60 Low speed 10 420 600 Super high speed Medium speed 20 110 70 High speed 30 Air flow (m 3/h) SYSVRF DUCT 90 Q Super high speed 40 10 200 400 280 Air flow (m 3/h) External static pressure (Pa) SYSVRF DUCT 71 Q 80 60 External static pressure (Pa) SYSVRF DUCT 45/56 Q 80 Medium speed 80 Low speed 60 40 20 1000 1020 1400 1800 2200 1400 10601000 Air flow (m 3/h) Air flow (m 3/h) 1800 2200 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 55 | VRF Duct HP indoor units High Static Pressure Duct Indoor Units SYSVRF DUCT HP Features External static pressure up to 250 Pa.  :DVKDEOHDLUʾOWHUSODFHGLQDQDOXPLQXPIUDPHZKLFK is removable downward from the bottom. Easy access both in rear and bottom.  )UHVKDLUKROHDLULQOHWRXWOHWʿDQJHDUHVWDQGDUGIRU easy duct connection.  (OHFWURQLFH[SDQVLRQYDOYH (;9 ʾ[HGLQVLGHRIWKH indoor unit. Display board with infrared receiver as standard equipment. Wired controller SYSCONTROL WC 90 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (standard) Accessories/option Infrared remote control SYSCONTROL RM 02 (optional) Wired controller SYSCONTROL WC 120 (optional) Infrared remote SYSCONTROL RM 02 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Dimensions SYSVRF DUCT HP 71/112 Q SYSVRF DUCT HP 140 Q 135 86 930 88 270 420 249 82 82 85 56 29 952 856 214 420 Plastic cover Plastic cover Electrical control box 24 46 68 Electrical control box SYSVRF DUCT HP 200/280 Q 936 200 75 50 378 60 96 1121 343 56 VRF Duct HP indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q 314129 314130 314131 314132 314133 V/Ph/Hz Cooling capacity 220-240/1/50 kW 7,1 11,2 14,0 20,0 28,0 W 263 524 724 1.516 1.516 Power Input Current A 1,1 2,3 2,7 6,6 6,6 kW 8,0 12,5 16,0 22,5 31,5 Power Input W 263 524 724 1.516 1.516 Current A 1,1 2,3 2,7 6,6 6,6 1.510/ 1.399/1.236 2.117/ 1.950/1.644 2.988/ 2.670/2.229 4.268/ 3.780/3.200 4.400/ 3.700/3.200 Heating capacity m3/h $LUʿRZ KLPHGORZ Sound pressure level (hi/med/low) External static pressure dB(A) Pa 48/46/44 52/49/47 53/50/48 59/55/52 59/55/52 40 (30~196) 50 (30~196) 50 (30~196) 140 (50~250) 160 (50~250) Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470 1.356x763x470 Packing (LxWxH) mm 1.090x768x440 1.090x768x440 1.436x768x450 1.509x964x570 1.509x964x570 Net/gross weight kg 45/50 50,6/56 68/70 115/129 115/129 Refrigerant R410A Piping dimension Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2) 32 32 32 32 32 Drain piping mm Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28 Fan performance SYSVRF DUCT HP 112 Q P(Pa) P(Pa) SYSVRF DUCT HP 71 Q 300 300 280 280 260 260 240 240 220 220 200 200 180 180 160 140 140 120 120 100 Midium speed Midium speed 100 80 60 High speed High speed 80 Low speed Low speed 60 40 40 20 20 0 800 1000 1200 1400 0 1600 1800 2000 400 600 Q(m3/h) Q( 3 /h) SYSVRF DUCT HP 280 Q P(Pa) SYSVRF DUCT HP 200 Q P(Pa) SYSVRF DUCT HP 140 Q 800 1000 1200 1400 1600 1800 2000 2200 300 300 280 280 260 260 240 240 220 220 200 200 180 180 160 160 High speed P(Pa) 160 300 280 260 High speed 200 Midium speed 120 120 100 100 80 80 60 60 40 40 40 20 20 100 Midium speed 80 Low speed 60 20 0 0 0 400 600 800 1000 1200 1400 2000 2500 3000 3500 4000 4500 5000 5500 6000 2000 2500 3000 3500 4000 4500 5000 5500 6000 1600 1800 2000 Q(m3/h) Low speed 160 140 120 Midium speed 180 Low speed 140 140 High speed 240 220 Q(m3/h) Q(m3/h) Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m The sound pressure value may vary depending on ambient conditions. 57 | VRF Heat Recovery Ventilation Heat Recovery Ventilation Units SYSVRF HRV Features  &URVVʿRZKHDWH[FKDQJHUPDGHRIVSHFLDOSDSHUIRU  HQKDQFHGKHDWH[FKDQHJHIʾFLHQF\ Main structure made of galvanized steel sheet.  +LJKHIʾFLHQWFHQWULIXJDOIDQDVVXUHVORZSRZHU consumption. 3 fan speeds available for sizes 500 m3/h and 1000 m3/h, 1 speed for size 2000 m3/h.  7HPSHUDWXUHH[FKDQJHHIʾFLHQF\DERYH  &RPSDFWGHVLJQDQGʿH[LEOHLQVWDOODWLRQLQWKHIDOVHFHLOLQJ Different operating modes available: heat exchange, bypass, auto, exhaust/supply mode. Insulation material guarantees quiet operation and thermal insulation. 7KDQNVWRWKHʿH[LEOHFRQWUROWKH+59XQLWFDQEH interlocked to the operation of the VRF indoor units. Wired controller SYSCONTROL WC 27 as standard equipment. SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 R Wired controller SYSCONTROL WC 27 (standard) Dimensions SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 R W L 75 1550 Door N2 H W2 C Wire control box Door Air exhaust vent By-pass Air return system vent W1 Fresh air inlet 1400 G Model SYSVRF HRV 500 Q SYSVRF HRV 1000 Q L 824 1.116 L1 754 1.045 W 904 1.134 W1 960 1.190 W2 500 678 H 270 388 C 107 85 G 19 19 N Ɗ Ɗ N2 111 170 540 700 250 1600 Air supply vent Air exhaust vent 1370 L1 350 Air supply vent Fresh air inlet 50 1650 Air return vent 50 326 N Wire control box 20 58 VRF Heat Recovery Ventilation | Technical features Model Indoor unit SYSVRF Art. no. Power supply HRV 500 Q HRV 1000 Q 314134 314135 V/Ph/Hz 314136 380/3/50 500/500/375 1.000/1.000/750 External static pressure (H/M/L) Pa 80/68/45 100/85/58 170 Power consumption W 120 360 450 (QWKDOS\H[FKDQJHHIʾFLHQF\ Cooling (H/M/L) % 50/50/55 50/50/55 50 (QWKDOS\H[FKDQJHHIʾFLHQF\ Heating (H/M/L) % 60/60/65 60/60/65 60 7HPSHUDWXUHH[FKDQJHHIʾFLHQF\ +0/ % 65/65/70 65/65/70 65 dB(A) 35/34/28 40/39/33 53 1.038x1.026x270 1.286x1.256x388 1.650x1.470x540 41 79 182 ʡ ʡ 346x326 $LUʿRZUDWH +0/ Sound pressure level (H/M/L) Dimensions (LxWxH) Unit weight m3/h 220-240/1/50 HRV 2000 R mm kg Duct connection dimensions Ambient condition mm °C 2.000 -7…+43/ max 80% RH Fan performance Air flow (m3/h) SYSVRF HRV 500 Q External static pressure (Pa) Air flow (m3/h) SYSVRF HRV 1000 Q External static pressure (Pa) Air flow (m3/h) SYSVRF HRV 2000 Q External static pressure (Pa) Nominal conditions Exhaust air Fresh air Cooling mode 27°C DB, 19,5°C WB 35°C DB, 28°C WB Heating mode 21°C DB, 13°C WB 5°C DB, 2°C WB The sound pressure value may vary depending on ambient conditions. 59 60 | VRF connection to AHU Connection of SYSVRF AHU SYSCONTROL AHU Features The SYSCONTROL AHU 5HP, 10HP and 20HP can be used to connect the SYSVRF outdoor units to an external DX AHU with capacity from 7 kW to 73 kW. Nominal capacity in cooling 14kW (5HP), 28kW (10HP) and 56kW (20HP). Modulating cooling/heating capacity thanks to the built-in Electronic Expansion Valve (EXV) controlled by the superheat degree of the AHU. The SYSCONTROL AHU kit includes four temperature sensors, one for the air intake of the AHU and three for a precise monitoring of the DX evaporator coil. For indoor installation in horizontal or vertical position. Failure alarm codes on the PCB for quick service checking. Environment friendly R410A refrigerant. Connection to Systemair network monitoring system. Connection diagram SYSVRF indoor units SYSVRF outdoor unit SYSCONTROL AHU SYSTEMAIR Air Handling Unit Technical features Model Indoor unit SYSVRF Art. no. Power supply AHU capacity SYSCONTROL AHU 10HP SYSCONTROL AHU 20HP 314188 314189 314190 V/Ph/Hz kW Dimensions (LxWxH) mm Packing (LxWxH) mm Piping diameters in/out mm IP-class SYSCONTROL AHU 5HP 220-240/1/50, 208-230/1/60 9-20 20-33 40-56 375x350x150 490x240x420 8/8 12,7/12,7 15,9/15,9 IP X0 IP X0 IP X0 VRF connection to AHU | SYSVRF selection and designing software Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF. Main tasks: Calculation of the heat loads and selection of the necessary cooling /heating capacity, type and location of outdoor and indoor units. Calculation of the refrigerant piping diameters and the required additional amount of refrigerant. Selection of an optimal set of piping joints. Building Management System. Correction of the performance of indoor units. Automatic check of the circuit for compliance requirements and limits on the maximum length of refrigerant pipelines and indoor-outdoor elevations. &RQFOXVLRQRISURMHFWGRFXPHQWDWLRQVSHFLʾFDWLRQ ([FHO DGHWDLOHGVSHFLʾFDWLRQZLWKWKHGUDZLQJV (Word), and print out of all documents. 61 62 | VRF control systems SYSCONTROL systems Remote control for indoor units Wireless infrared remote control SYSCONTROL RM 02 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting , fan speed selection (high/medium/low/auto), 24h on/off WLPHU785%2PRGH(&2PRGHDLUʿRZVZLQJDGMXVWPHQWGLVSOD\EDFNOLJKWEXWWRQ FOLLOW ME functions, keyboard locking function, 26 °C button. Standard equipment for SYSVRF WALL, CASSETTE, CEILING. For 2-pipe and 3-pipe SYSVRF. (Art. no. 314138). Wired controller SYSCONTROL WC 90 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting, fan speed selection (high/medium,low/auto), real 24h on/off timer, swing button. Standard equipment for SYSVRF DUCT, DUCT HP. Designed for 2-pipe SYSVRF HP with automatic cooling/heating changeover. It can be used for 3-pipe SYSVRF HR with manual cooling/heating changeover. (Art. no. 314139). Wired controller SYSCONTROL WC 120 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting , fan speed selection (high/medium/low/auto), 24h on/off timer, DLUʿRZVZLQJDGMXVWPHQWDLUʾOWHUIXQFWLRQNH\ERDUGORFNLQJEXWWRQ 2SWLRQDO HTXLSPHQW IRU DOO VHULHV RI 6<695) LQGRRU XQLWV 6SHFLʾFDOO\ GHVLJQHG IRU 3-pipe SYSVRF HR systems with automatic cooling/heating changeover and adjustable dead band. It can be used in 2-pipe SYSVRF HP systems. (Art. no. 314182). Centralized controllers Centralized controller SYSCONTROL CWC 03 HP/HR Monitors and manages 64 indoor units. Main functions: on/off, setting modes (including the lock mode), change temperature settings, fan speed selection, query function and error code of indoor units LCD with backlight. Provides the ability to connect to a PC via a converter RS485/RS232. (Art. no. 314140) CWC 03 HP for 2-pipe SYSVRF HP. (Art. no. 314183) CWC 03 HR for 3-pipe SYSVRF HR. Centralized controller SYSCONTROL CWC 09 Monitors and manages 64 indoor units. Perform the same functions of the central control SYSCONTROL CWC 03, with the possibility of drawing up management program for the week. LCD with backlight it doesn't have the port for the connection to a PC. (Art. no. 314141). Centralized monitoring of outdoor units SYSCONTROL CWC 02 Monitors up to 32 outdoor units which may be included in the 8 different VRF air conditioning systems. When using a powermeter tra performs the accounting function of electricity consumed. Ability to connect to a PC via a converter RS485/RS232. (Art. no. 314142). VRF control systems | Intelligent Network Management System Systemair multi-zone system can be integrated into a comprehensive building management system (BMS) thanks to the Bacnet, Modbus or LonWorks gateway via SYSCONTROL CWC 08/CWC 11/CWC 64, respectively. With the implementation of these gateway it is possible to use different control schemes: individual, group, network. To one gateway Bacnet SYSCONTROL CWC 08 (Art. no. 314145) can be connected to up to 4 remote central control (SYSCONTROL CWC 02 /SYSCONTROL CWC 03). Each group can contain a maximum of 64 indoor units/32 outdoor units. Bacnet SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120 SYSCONTROL CWC 03 BMS SYSCONTROL CWC 08 SYSCONTROL CWC 03 SYSCONTROL CWC 03 S SCO RO SYSCONTROL CWC 02 The central management console (SYSCONTROL CWC 03) can be connected to one gateway Modbus SYSCONTROL CWC 11 (Art. no. 314143). Each group can contain a maximum of 64 indoor units. Modbus BMS SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120 SYSCONTROL CWC 11 SYSCONTROL CWC 03 Up to 64 indoor units can be directly connected to one gateway Lonworks SYSCONTROL CWC 64 (Art. no. 314144). LonWorks BMS SYSCONTROL RM 02 SYSCONTROL CWC 64 SYSCONTROL WC 90/WC 120 63 64 | VRF piping joint Piping joints for 2-pipe refrigerant system SYSVRF JOINT Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series Use SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN: SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 16,6-33kW SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-66kW SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 66-92kW SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units 92-135kW SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units > 135kW Indoor unit Use VRF piping joint | Piping joints for 3-pipe refrigerant system SYSVRF JOINT Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series Use SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN: SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW Indoor unit Use 65 Notes www.systemair.com Systemair - April 2014