Preview only show first 10 pages with watermark. For full document please download

T200a Universal Tester Mode Prim

   EMBED


Share

Transcript

Single Phase Relay Tester Primary Injection Model T1000 Primar y Injection and Test Equipment T200A Universal Tester Specifications Features High power AC current output (I1) Range Accuracy Output voltage Power Load time Output Time 0.2A~20A 10~250A ±0.5% 130V~100V 2000VA(20A) 250A 120s 10V~8V 2000VA(250A) 50A 3000s <50A continuous High power AC voltage output (U1) Range Accuracy Power Load time <1A : 1~3A : 10~500V ±0.5% 1200VA(400V) continuous Max 60min 10~300V ±0.5% 750W(300V) < 1A >1 A continuous Max 60min Auxiliary DC voltage output (Aux Udc) Range Accuracy Power Load time 20~240V ±1% 55W at 110V/110W at 220V continuous at 0.5A AC/DC current output (I2) Mode AC output Range 0~20A Accuracy ±0.5% Power(20A) 200VA Frequency 20~100Hz Phase angle 0~360° Phase angle accuracy 0.5 ° Distortion 1A~20A <0.5% Transient response Load time 20A : 10A : <10A : Harmonic(2nd,3rd,5th,7th)accuracy DC output 0~20A ±0.5% 200W — — — — 500μs 60s 240s continuous AC output 0~120V ±0.5% 60VA 20~100Hz 0~360° 0.5 ° <0.5% 500μs Number Input characteristics Time resolution Max. measuring time AC output 0~200mA ±0.5% 3VA 20~100Hz DC output 0~200mA ±0.5% 3W — 1% DC output 0~120V ±0.5% 80W — — — — 500μs 2 30~250V DC, or dry contact ±1ms(0.001~1s) ±0.1%(1~9999.999s) 9999.999s Binary output Number Type Break capacity AC Break capacity DC 1 Potential free relay contacts Vmax 250V AC / Imax 8A / Pmax 2000VA Vmax 250V DC/ Imax 8A / Pmax 150W Specifications High power AC current output (I1) Range Output voltage Accuracy Power Load time 2A~50A, 50A~1000A 20V 7V ±0.5% 7000VA 120s at 1000A Power supply High power AC voltage output (U1) Nominal input voltage Permissible tolerance Nominal frequency Permissible frequency 110/220Vac -20% ~+15% 50/60Hz 45~65Hz Range Accuracy Power Load time 0~600V AC/DC ±1% Range Accuracy Power Load time Range Accuracy Ammeter 0~6A AC/DC ±1% Certificates EMC (Emission) EMC (Immunity) Safety IEC-61000-3-2/3 IEC 61000-4-2/3/4/5/6/11 IEC 61010-1 Others - 5 ~ +45°C 5 ~95 %, non-condensing 23kg 440 mm×255mm×255 mm USB 4 mm banana socket; front side 10~300V ±0.5% 750W(300V) >1 A Output : < 1A Time : continuous Max 60min Auxiliary DC voltage output (Aux Udc) Range Accuracy Power Load time 20~240V ± 1% 55W at 110V/110W at 220V continuous at 0.5A Ammeter Range Operation temperatur Operation humidity Weight Dimensions (W x H x D) PC connection Ground Socket (earth) 10~250V ±0.5% 750VA(250V) continuous High power DC voltage output (Udc) Voltmeter Range Accuracy AC/DC voltage output (U2) Mode Range Accuracy Power(120V) Frequency Phase angle Phase angle accuracy Distortion 5V~120V Transient response Mode Range Accuracy Power(200mA) Frequency Binary inputs High power DC voltage output (Udc) Range Accuracy Power (300V) Load time Output : Time : High precision AC/DC current output (I3) 2 minutes continuous output at1 000A Manual and Ramp control CT test functions available Independent Aux DC supply In-built multi-meter funtion Weight : 37kg Accuracy 0~6A AC direct measurement 0~2000A AC with external CT ±1% Binary inputs Number Input characteristics Time resolution Max. measuring time 2 ( auto detection ) ±30 ~ ±250Vdc, or potential free ±1ms ( 0.001~1s ) ±0 . 1% ( 1~9999.999s ) 9999.999s Binary output Number Type Break capacity AC Break capacity DC 1 Potential free relay contacts Vmax 250V AC / Imax 5A / Pmax 1250VA Vmax 250V DC/ Imax 5A / Pmax 150W Power supply Nominal input voltage frequency 220VAC±15% 45~65Hz Others Operation temperature Operation humidity Weight Dimensions (W x H x D) PC connection Ground Socket (earth) -5 ~ +50°C 5 ~95 %, non-condensing 37kg 260 ×330×500 mm USB 4 mm banana socket; front panel Certificates Voltmeter Range Accuracy 0~600V AC/DC ± 1% EMC (Emission) EMC (Immunity) Safety 18 IEC-61000-3-2/3 IEC 61000-4-2/3/4/5/6/11 IEC 61010-1