Transcript
EC type-approval Certificate Number T7390 revision 2 Project number 12200481 Page 1 of 1 Issued by
NMi Certin B.V., designated and notified by the Netherlands to perform tasks with respect to conformity modules mentioned in article 9 of Directive 2009/23/EC, after having established that the measuring instrument meets the applicable requirements of Directive 2009/23/EC, to:
Manufacturer
GRUPO EPELSA, S.L. c/. Punto Net, 3 Polígono Industrial TECNOALCALÁ 28805 Alcalá de Henares (Madrid) SPAIN
Measuring instrument
A Non-automatic weighing instrument Type : UHRS
Further properties are described in the annexes: Description T7390 revision 2; Documentation folder T7390-3. Valid until
2 April 2018
Remarks
This revision replaces the earlier versions, including its documentation folder.
Issuing Authority
NMi Certin B.V., Notified Body number 0122 13 December 2012
C. Oosterman Head Certification Board
101
NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands T +31 78 6332332
[email protected] www.nmi.nl
This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability. The designation of NMi Certin B.V. as Notified Body can be verified at http:// ec.europa.eu/enterprise/newapproach/nando/
Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see www.nmi.nl). Reproduction of the complete document only is permitted.
Description Number T7390 revision 2 Project number 12200481 Page 1 of 7 1
General information about the non-automatic weighing instrument
All properties of the non-automatic weighing instrument, whether mentioned or not, shall not be in conflict with the legislation. 1.1
Essential parts
500
See the following drawings: Number
Pages
Description
Remarks
7390/0-23
1
Block diagram for 20 RL-I option
-
7390/0-24
1
Block diagram for 22 V14 option
-
7390/0-25
1
Block diagram for 20 V14 GRAFICO option
-
7390/0-26
1
Block diagram for 20 RL-SS 80T GRAFICO option
-
7390/0-27
1
Block diagram for 20 RL-P GRAFICO option
-
7390/0-28
1
Block diagram for 22 RL-I GRAFICO option
-
7390/0-29
1
Block diagram for 11 V12 LCD option
-
7390/1-08
1
Block diagram for 10 IV4 option
-
7390/1-09
1
Block diagram for 20 IV4 option
-
7390/1-10
1
Block diagram for 22 IV4 option
-
7390/2-13
1
Block diagram for 20.I touch screen option, counter type with pole
-
7390/2-14
1
Block diagram for 20.RL touch screen option, counter type with pole and thermal label printer
-
7390/2-15
1
Block diagram for 20.RLI touch screen option, counter type with pole, tally roll thermal printer and thermal label printer
-
7390/2-16
1
Block diagram for 20.I touch screen option, hanging type with tally roll thermal printer
-
7390/2-17
1
Block diagram for 20.RL touch screen option, hanging type with thermal label printer
-
7390/2-18
1
Block diagram for 20.RLI touch screen option, hanging type with tally roll thermal printer and thermal label printer
-
Description Number T7390 revision 2 Project number 12200481 Page 2 of 7 The electronics; The mechanical assembly with load cell. EMC protection measures: - 2 ferrites on the cable between load cell and main board, (1 turn); - 2 ferrites on the load cell cable (only counter scales), (1 turn); - 1 ferrite ref. NF-100 from Ferrico or equivalent in the rear display cable, (1 turn); - 1 ferrite on power supply, (6 turns); - 1 ferrite on grounding wire, (6 turns); - 1 metal cover over the analogue part at the side of the load cell. 1.2
Essential characteristics
Accuracy class
III
Maximum capacity
6 kg
Verification scale interval Maximum number of scale intervals
e
Single interval Multi interval
Max
n n
30 kg
1g
6000 divisions
3000 divisions per partial weighing range
Maximum partial weighing ranges
2
Temperature range
0 °C / 40 °C
Tare
T
Weighing range(s)
-Max
Single- or multi-interval
Application
Intended to be used for direct sales to the public 220 - 230 V AC 50/60 Hz; 12 V / 5 A battery (optional)
Power supply voltage Software identification
X-XXXXXXXX-XXX-1 (X may be a letter from A to Z or a number from 0 to 9, the last digit 1 is representing the metrological software part);
Software: - The identification number will be displayed at start-up. 1.3
Essential shapes
500
The non-automatic weighing instrument is built according to the drawings: Number
Pages
Description
Remarks
7390/0-01
1
Exploded view of 20RL-I option
-
7390/0-02
1
Front and side view of 20RL-I option
-
Description
500
Number T7390 revision 2 Project number 12200481 Page 3 of 7 Number
Pages
Description
Remarks
7390/0-03
1
Exploded view of 22 V14 option
-
7390/0-04
1
Front and side view of 22 V14 option
-
7390/0-05
1
Exploded view of 20 V14 GRAFICO option
-
7390/0-06
1
Front and side view of 20 V14 GRAFICO option
-
7390/0-07
1
Exploded view of 20 RL-SS 80T GRAFICO option
-
7390/0-08
1
Front & side view 20 RL-SS 80T GRAFICO option
-
7390/0-09
1
Exploded view of 20 RL-P GRAFICO option
-
7390/0-10
1
Front and side view of 20 RL-P GRAFICO option
-
7390/0-11
1
Exploded view of 22 RL-I GRAFICO option
-
7390/0-12
1
Front and side view of 22 RL-I GRAFICO option
-
7390/0-13
1
Exploded view of 11 V12 LCD option
-
7390/0-14
1
Front and side view of 11 V12 LCD option
-
7390/1-01
1
Exploded view of 10 IV4 option
-
7390/1-02
1
Front and side view of 10 IV4 option
-
7390/1-03
1
Exploded view of 20 IV4 option
-
7390/1-04
1
Front and side view of 20 IV4 option
-
7390/1-05
1
Exploded view of 22 IV4 option
-
7390/1-06
1
Front and side view of 22 IV4 option
-
7390/2-01
1
7390/2-02
1
7390/2-03
1
7390/2-04
1
7390/2-05
1
Exploded view of 20.I touch screen option, counter type with pole Front and side view of 20.I touch screen option, counter type with pole Exploded view of 20.RL touch screen option, counter type with pole and thermal label printer Front / side view of 20.RL touch screen option, counter type w. pole and thermal label printer Exploded view of 20.RLI touch screen option, counter type with pole, tally roll thermal printer and thermal label printer
-
Description Number T7390 revision 2 Project number 12200481 Page 4 of 7 Number 7390/2-06
Pages 1
7390/2-07
1
7390/2-08
1
7390/2-09
1
7390/2-10
1
7390/2-11
1
7390/2-12
1
Description Front and side view of 20.RLI touch screen option, counter type with pole, tally roll thermal printer and thermal label printer Exploded view of 20.I touch screen option, hanging type with tally roll thermal printer Front / side view of 20.I touch screen option, hanging type w. tally roll thermal printer Exploded view of 20.RL touch screen option, hanging type with thermal label printer Front / side view of 20.RL touch screen option, hanging type w. thermal label printer Exploded view of 20.RLI touch screen option, hanging type with tally roll thermal printer and thermal label printer Front and side view of 20.RLI touch screen option, hanging type with tally roll thermal printer and thermal label printer
Remarks -
-
The descriptive markings plate is secured against removal by sealing or will be destroyed when removed. 1.4
Conditional parts
The non-automatic weighing instrument may be equipped with peripheral equipment which is used for the applications listed in article 1(2)(a) of Directive 2009/23/EC, provided that the peripheral equipment is certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type examination under Directive 2009/23/EC, or that the equipment and the use of the equipment comply with the requirements of WELMEC 2.5 Issue 2 Section 2.2. The non-automatic weighing instrument may be equipped with an Electronic Point of Sale (EPoS) or an Electronic Cash Register (ECR), provided that these EPOS and ECR are certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type examination under Directive 2009/23/EC. The non-automatic weighing instrument may be equipped with Electronic Funds Transfer equipment (EFT/ECU), if these EFT/ECU represent only the price total on the display. The non-automatic weighing instrument is fitted with a levelling device and a level indicator, unless the instrument is installed in a fixed position. A ring on the level indicator indicates when the maximum tilt is exceeded. 1.5
Non-essential parts
500
The non-automatic weighing instrument may be connected to non-essential devices, for example but not limited to bar code readers, foot switches, second display’s and cash drawers, provided that: - They do not present primary data used for purposes mentioned in article 1(2)(a) of
Description Number T7390 revision 2 Project number 12200481 Page 5 of 7
-
Directive 2009/23/EC unless the "preliminary observations" in Annex 1 of this directive is satisfied; They do not lead to an instrument having other essential characteristics than those fixed by this type-approval document.
2
Information about the main constituent parts of the non-automatic weighing instrument
2.1
The electronics
2.1.1 Essential parts Number
Pages
Description
Remarks
7390/0-17
2
ADC Board including parts list
-
7390/0-18
5
CPU Boards (normal & simplified) plus parts list
-
2.1.2 Essential characteristics List of legally relevant functions: - Determination stability of equilibrium; - Indication of stable equilibrium; - Zero indicator; - Semi-automatic zero-setting; - Initial zero-setting; - Zero-tracking; - Semi-automatic subtractive tare weighing; - Preset tare; - The calibration mode is secured with a password, this software seal uses an event counter that contains a number that will be incremented each time any parameter changes or calibration change is made and saved; - Acting upon significant faults; - Checking the display; - Price calculation.
500
When equipped with a printer the following legally relevant function may be present: - Indications other than primary indications; - Indication of additional information; - Memory storage; - Non-weighed articles; - Totalization; - Multi-vendor; - Price labeling; - PLU function.
Description Number T7390 revision 2 Project number 12200481 Page 6 of 7 2.1.3 Conditional parts Number
Pages
Description
Remarks
7390/2-19
4
Power supply including parts list
-
The non-automatic weighing instrument may be equipped with one or more of the following protective interfaces that have not to be secured: - RS232; - Serial neuron communication (Lonworks); - Ethernet. 2.1.4 Non-essential parts Display; Keyboard; Internal printer; Label printer. 2.2
The mechanical assembly with load cell
2.2.1 Essential parts Number
Pages
Description
Remarks
7390/0-20
1
Load Cell BP/C
For hanging scales
7390/0-21
1
Load Cell MVB
For bench scales
2.2.2 Essential characteristics e Emax/10000, or e1 Emax/10000 in case of multi-interval instrument; Excitation power supply 10 V DC. 2.2.3 Essential shapes
500
See drawings: - “Precinto Celula Colgante”, drawing number 7390/0-15 (hanging scales); - “Precinto Celula MVB Sombremostrador Balanza 20RL”, drawing number 7390/0-16 (counter scales).
Description Number T7390 revision 2 Project number 12200481 Page 7 of 7 3
Seals
To secure components that may not be dismantled or adjusted by the user, the non-automatic weighing instrument has to be secured in a suitable manner on the locations indicated in the drawings: - “Precinto Celula Colgante”, drawing number 7390/0-15 (hanging scales); - “Precinto Celula MVB Sombremostrador Balanza 20RL”, drawing number 7390/0-16 (counter scales). 4
Conditions for conformity assessment
500
The marks, facilities for the marks and the inscriptions on the non-automatic weighing instrument fulfill the requirements of article 1 of Annex IV of Directive 2009/23/EC.