Preview only show first 10 pages with watermark. For full document please download

Ta01c / Ta01c4 Winprox For 5,000 Id Card Users And 50,000

   EMBED


Share

Transcript

RFID Access Controller / Time Clock with Time Attendance Software TA01C / TA01C4 WinProx for 5,000 ID Card Users and 50,000 Transaction Records Dimensions: 114mm x 162mm x 37mm INTRODUCTION The WinProx series proximity readers are powerful offline solution for access control and time recording / attendance. It can accept up to 5,000 ID card users and store 50,000 transaction records. With Time Attendance software, it can also capture the photo if a PC camera is connected to the computer. Transaction records in offline readers can download to Time Attendance software easily. Hence, reports can be generated accordingly. There are four mode of operation for TA01C as follows: 1. Access Control (Outside / Single reader) - IN mode - Entrance with or without password In this mode, only a single reader is installed outside the premises. An electric door lock can be connected. A bypass switch is installed inside the premises, pressing it will release the door lock. Also, authorized cards will release the door lock too. A door magnet can be used to feedback the state of the door. The door will not be locked until the door magnet is short circuit. The reader’s states and card information can be uploaded by the Time Attendance software through the RS232 communication port. (ADJUST LCD CO NT RAST) ( Short c i rcui t i f not used ) DOOR M AGNET GND ( P O W E R 9 -12V 5 00mA DC I N B YPA S S SWI TC H (R X to T D) ( F or KS23 2U DATA F ROM SL AV E RX to T X & T X to RX)) DATA TO SLAVE (TX t o RD) GN D - D B 9 PIN 5 DATA FROM PC - DB9 PIN 3 DATA TO PC - DB9 PI N 2 RS2 3 2 PORT (To c omp u te r ) G N D ( TO EL ECT RI C LOC K) D C OUT NORMAL CLOSE (RE L AY ) COMMON NORMAL OPEN DC IN TERMINAL - Connect to the 12V DC power for the reader and the DC OUT terminal for driving a electric lock. IN1 TERMINAL (Door Magnet) - Connect to the door magnet in order to feed back the status whether the door is closed. The reader will wait for this signal before locking the door. If no door magnet connected, it should be short circuit otherwise the door will not be locked. IN2 TERMINAL (Bypass switch) - Connect to a normal open push button, pressing the button will open the door. SLAVE TERMINAL - Connect to a slave reader. PC TERMINAL - Connect to a PC for setup and database. DC OUT TERMINAL - Connect to a electric lock. The power is output from the DC IN terminal through the control of a relay directly. RELAY TERMINAL - SPDT relay output for external control. 2. Access Control (Outside / Dual readers) - IN mode - TA01C as MASTER for entrance with or without password + KS232U/F as SLAVE f or exit In this mode, two readers are installed. The TA01C is installed outside the premises as the master. An KS232F or KS232U is installed inside the premises as the slave unit. An electric door lock and a bypass switch are connected to the slave and are installed inside the premises. Pressing the bypass switch and authorized cards will release the door lock. A door magnet can be connected to the master to feedback the state of the door. The door will not be locked until the door magnet is short circuit. The reader’s states and card information can be uploaded by the Time Attendance software through the RS232 communication port. (TO ELECTR I C LOCK) (BYPA S S SWITCH ) + - + (TO POWER) GND DC IN (ADJUST LCD CONTRAST) GND DC O UT (Shor t ci r cuit i f n o t use d ) DOOR MAGNET GN D (POWE R 9 -12V 500m A DC I N K S 23 2 F BYPA S S SW I TCH GND ( R X t o T D) (F o r KS232U DATA FROM SL AVE RX to TX & TX t o RX ) ) DATA TO S L AV E (T X to R D) GN D - D B 9 PIN 5 D ATA F R OM P C - D B9 PIN 3 O PEN SW G N D(TO ELECTR I C LOCK) DC O UT DATA TO PC - DB9 PIN 2 NORMAL CLOSE COMMON RS2 3 2 PORT ( To c o mpu t e r ) G DN DATA FROM PC DATA TO PC NORMAL OPEN RS2 3 2 POR T (RELAY ) RS232 ( DB 9 soc ke t ) To compu t er *** Remove al l j u mp e r s on slave 3. Access Control (Inside / Dual readers) - OUT mode - TA01C as MASTER for exit + KS232U/F as SLAVE for entrance In this mode, two readers are installed. The TA01C is installed inside the premises as the master. An KS232F or KS232U is installed outside the premises as the slave unit. An electric door lock and a bypass switch are connected to the master and are installed inside the premises. Pressing the bypass switch and authorized cards will release the door lock. A door magnet can be connected to the master to feedback the state of the door. The door will not be locked until the door magnet is short circuit. The reader’s states and card information can be uploaded by the Time Attendance software through the RS232 communication port. D o or Magnet (Shor t ci r cuit i f not used) *** Remove al l j u mp e r s on s lave (BYPASS SWITCH) GND DC IN (ADJU S T L C D CONTRA S T) ( S h o r t ci rc u i t if n o t u s e d ) DOOR M A GN E T GN D D C OUT GND (P OW ER 9- 12V 500m A D C IN KS 2 32F BYPASS S W ITCH GN D OPEN S W (RX to TD) ( For KS23 2 U DATA FROM SLAVE RX to T X & TX t o RX ) ) DATA TO S LAV E ( T X to RD ) GN D - D B9 PI N 5 D ATA F RO M PC - D B9 PIN 3 G N D ( TO ELECTRIC LO C K ) DC OUT D ATA TO P C - DB9 PI N 2 NORMAL CLOSE COMMON (RELAY) R S 232 P O R T ( To compu t er) GND DATA FR O M PC DATA TO PC NORMAL OPEN RS232 PORT - (TO P OWER) RS 2 32 (DB9 so c ket) To c omputer - + + ( TO ELECTRIC LO C K ) OTHER CO N TROL (OPTIO N AL) 4. As Time Clock / Time Recorder - Connect the RS232 port and power to the TA01C In this mode, no access control is enabled. It is used for recording the time that cards are presented. (ADJUST LCD CONTRAST) (Short circuit if not used) DOO R MAGNET GND ( P OWER 9- 12 V 50 0m A DC I N 2 BYPASS SWI TC H (R X to TD) (For KS232U DATA FROM SLAVE RX to TX & TX to RX)) DATA TO SLAVE ( T X t o RD) GND - DB9 PIN 5 DATA FR O M PC - DB9 PIN 3 GND ( TO EL ECT RI C LO CK) DC O UT DATA TO PC - D B 9 PIN 2 1 NORMAL CLOSE ( RE L AY ) COMMON RS232 PO RT (To c om pu t er ) NORMAL OPEN KEYPAD FUNCTIONS Enter PASSWORD in “IN” mode for entrance - Present the ID card to the reader, then enter the preset “PASSWORD” + “#” to end. MEMORY USAGE - Press “0” to check for number of ID card users and transaction records. Number of transaction records stored MEMORY USAGE Log=00042/53592 Acc=00003/05088 Total number of transaction records can be stored Total number of ID card can be stored Total number of ID card stored IN CLOCK mode with Auto IN/OUT time, use “#” to change from IN to OUT or vice versa. STAFF CHECK - Press “*” then present the ID card to the reader. Use “ 2 ” to go to the previous record and press “ 8 ” to go to the next record. Quick Start: 1.Connect cables and power to the TA01C 2. Turn on the computer. 3. Insert the Time Attendance CD into your computer's CD-ROM drive. The Installer will start by itself automatically. If the Installer doesn't start automatically, you can run the setup.exe program to install the software. The detailed installation manual for the Time Attendance will be automatically installed into your computer when you install the application software. Follow the installation instruction to finish the installation and follow the Installation Manual of Time Attendance from Start for details of Time Attendance's Setup. Installation Manual of Time Attendance from Start 6. Define the workgroup 8. Setup the RFID reader 9. Setup the Offline Reader Manager 5. Login the Time Attendance to start SETUP 4. Setup the password for LOGIN (Password cannot be reversed) 7. ADD Cards and enter Card Information (By selecting the serial no. on CD ROM of your card pack)