TABULAR DATA SHEET OUTDOOR SPLIT SYSTEM HEAT PUMP MODELS: E*RD018* - 060* 13 SEER 1-1/2 - 5 TONS Physical and Electrical Data
MODEL
E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 E1RD048S06 E1RD060S06
Unit Supply Voltage Normal Voltage Range
208/230 – 1 – 60 1
187 to 252
Minimum Circuit Ampacity
9.9
15.0
16.9
19.8
25.0
32.7
37.8
15
25
25
30
40
50
60
Recip
Recip
Recip
Recip
Recip
ScrollB
ScrollB
Rated Load
7.5
10.7
12.4
14.6
18.8
25.0
29.1
Locked Rotor
41
44
60
78
78
115
150
Crankcase Heater
Yes
Yes
Yes
Yes
Yes
No
No
Fan Motor Amps Rated Load
0.5
1.5
1.5
1.5
1.5
1.5
1.5
Fan Diameter Inches
22
22
22
22
22
24
24
Rated HP
1/15
1/4
1/4
1/4
1/4
1/4
1/4
Nominal RPM
850
850
850
850
850
850
850
Nominal CFM
2,000
3,250
3,450
3,500
3,500
3,400
3,500
Face Area Sq. Ft.
15.72
18.34
20.96
23.58
23.58
24.00
27.00
Rows Deep
1
1
1
1
1
2
2
Fin / Inches
22
22
22
22
22
18
18
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
7/8
7/8
7/8
7/8
7/8
7-1
7-9
8-7
8-7
8-7
12 - 8
16 - 8
Charge Per Foot, Oz.
0.68
0.68
0.70
0.70
0.70
0.70
0.70
Operating Weight Lbs.
172
184
196
208
208
250
294
Max. Overcurrent Device Amps
2
Compressor Type 3 Compressor Amps
Fan Motor
Coil
Unit Charge (Lbs. - Oz.)
1. 2. 3. 4.
4
Rated in accordance with ARI Standard 110, utilization range “A”. Dual element fuses or HACR circuit breaker. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
C
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
A
B
Refrigerant Connection Service Valve Size
Dimensions (Inches)
Unit Model A1
B
C
018
27
35
23
024
31
37
27
030
35
37
27
036
39
37
27
042
39
37
27
048
34
43
32
060
38
43
32
Liquid
Vapor 3/4”
3/8” 7/8”
1. Including Fan Guard
Unitary Products Group
155581-YTD-B-0905
R-22 SYSTEM CHARGING PROCEDURE Additional R-22 Charge / Orifice Size for Various Matched Systems Outdoor Unit Required TXV Factory R-22 Charge, lbs-oz Indoor Coil1 G2FD024(S,H)14,17 G2FD030(S,H)17 G2FD035(S,H)14 G2FD036(S,H)17 G2FD036(S,H)21 G2FD042(S,H)21 G2FD046(S,H)17 G2FD048(S,H)21,24 G2FD060(S,H)24 G2FD061H24 G1HA024H14 G1HA036H14 G1HA036H17 G1HA048H21 G1HA060H24 G1HD024 G1HD036 G1HD048 G1HD060 G1NA030S17K G1NA030S21M G1NA036S17J G1NA036S21C G1NA036S17L G1NA042S24W G1NA048S21D G1NA060S24T G1FA/G1UA024S14,17 G1FA/G1UA030S14 G1FA/G1UA036S14 G1FA/G1UA036S17,21 G1FA/G1UA048S17 G1FA/G1UA048S21 G1FA/G1UA060S21,24 F2RP/F2FP024 F2RP/F2FP030 F2RP/F2FP036 F2RP/F2FP042 F2FP048 F2FP060 F2FV060 G1FA036S14T G1FA048S17T G1FA048S21T G2FD036(S,H)17T G2FD036(S,H)21T G2FD042(S,H)21T G2FD046(S,H)17T G2FD048(S,H)21,24T G1HA036H14T G1HA036H17T G1HA048H21T F3FP024 F3FP030 F3FP036 F3FP042 F3FP048 F3FP060 F3FV060
Coil Orifice2 61 65 65 75 75 78 78 84 90 90 61 75 78 84 90 59 69 81 93 63 63 67 67 71 84 78 87 59 65 73 73 84 84 90 61 65 75 78 84 90 90 -
E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 E1RD048S06 E1RD060S06 1TV0702 1TV0702 1TV0703 1TV0703 1TV0705 1TV0706 1TV0706 7-1 7-9 8-7 8-7 8-7 12 - 8 16 - 8
TXV Kits3 + Additional Charge, Oz 702 + 0 702 + 2 702 + 2 702 + 5 702 + 10 703 + 2 703 + 2
703 + 6 703 + 9
705 + 14 706 + 7 706 + 14
706 + 7 706 + 13
706 + 7
706 + 7
706 + 0
706 + 0
706 + 0
706 + 0
706 + 7
706 + 7
706 + 7 706 + 7
706 + 7 706 + 7
702 + 0 702 + 12 702 + 9
703 + 2 703 + 9
703 + 5
705 + 7
702 + 0 702 + 4 703 + 3
703 + 0
705 + 0
702 + 1 702 + 1 702 + 2 702 + 2 703 + 0 703 + 0
705 + 0 703 + 6
702 + 0 702 + 3 702 + 2 703 + 2 703 + 9
703 + 6
705 + 7
702 + 0 702 + 10 703 + 2
703 + 6 705 + 14
3 2 9
6
5 10 2 2 12 9
6 9
14
2 9
5
7
2
6
10
FOOTNOTES:
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit #6918A5011. 2. These orifices are factory mounted in the flow device of each indoor coil. 3. A TXV kit must be used with these coils to obtain system performance (701, 702, 703 indicates 1TV07 …series). PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and the additional charge required for the specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base charge (as shipped) + adder for evaporator + adder for line set. 5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice/TXV size. Subject to change without notice. Printed in U.S.A. 155581-YTD-B-0905 Copyright © by York International Corp. 2005. All rights reserved. Supersedes: 155581-YTD-A-0705
Unitary Products Group
5005 York Drive
Norman OK 73069