Transcript
Table of Contents ServerLink Eco KVM Rack Drawer ■ Introduction Overview ............................................................................................1 Features .............................................................................................2 Configurations ....................................................................................3 Front Panel Control............................................................................5
■ Installation Rack Cabinet .....................................................................................6 Device Connection for LKS-1017E ....................................................8 Device Connection for LKS-8017E & LKS-16017E ...........................9 Initial Power-up ..................................................................................9
■
Operation
Push Buttons .....................................................................................10 OSD (On-Screen Display) Operation ................................................11 Hotkey Commands ............................................................................15
■ Cascade Configuration Connection .........................................................................................17 Change Configuration while Running ................................................18
■ Appendices Specifications .....................................................................................19 LCD Panel Specification ....................................................................20 Video/Keyboard/Mouse Specification ................................................20 Troubleshooting .................................................................................21
Please read this manual thoroughly and follow the Installation procedures to prevent any damage to the system or any connecting device.
ServerLink Eco KVM Rack Drawer
------------------------ Introduction Overview The ServerLink Eco KVM Rack Drawer is the most efficient and space-saving way of managing multiple computers in a 19” rack cabinet. With its OSD features, you can name your computers, switch to a computer from a list, configure settings with easy-to-use menus, and view the name of the selected computer on-screen with programmable time interval. The ServerLink Eco KVM Rack Drawers are available in 3 different models: Fig1: LKS -1017E
Built-In AC Power Fig 2:
Simply plug an AC Cord and apply the power, then switch on, the green LED will be lit to show the unit is powered up properly.
Page 1
ServerLink Eco KVM Rack Drawer
Features
Cascade configuration expands system capability Auto-scan automatically selects computers sequentially Assign computers with unique and meaningful names with 14 characters Identify and select computers by name Programmable scan filters unused computers Store system settings and name entries to non-volatile memory Password security locks computer from unauthorized access Gain complete control with easy-to-use OSD interface Hotkey functions allow easy computer access Keyboard states automatically saved and restored when switching computers Operating system independent, transparent to all applications Plug and play system configuration Keyboard and mouse can be hot plugged at any time DDC2B compatible Uses standard connectors for computer connection Built-in power. No power adapter required.
Page 2
ServerLink Eco KVM Rack Drawer
Configurations ServerLink Eco KVM Rack Drawers are available in single, 8 or 16 port models. For applications requiring many computers, the Rack Drawer can be cascaded in a master/slave configuration.
Single Rack Drawer Configuration The ServerLink Eco KVM Rack Drawer can be connected to multiple computers with keyboard, mouse and monitor cables as shown in Figure 4.
Figure 4: A single Rack Drawer configuration (ex: 1-8 port)
Page 3
ServerLink Eco KVM Rack Drawer
KVM Rack Drawer in cascade (Master/Slave) Configuration The Rack Drawer (Master), for example, when combined with additional KVM switches (Slave), expands system ability, allowing you to access up to 136 computers connected to the Master or Slaves.
Figure 5: A cascaded Rack Drawer configuration (ex: 1-8 port)
Throughout this manual, Master is the ServerLink Eco KVM Rack Drawer. Slave is a KVM Switch that has its CONSOLE port connected to an ServerLink Eco KVM Rack Drawer “PC x” port. Slave only exists in cascade configuration.
Page 4
ServerLink Eco KVM Rack Drawer
Front Panel Control
Front panel of LKS-8017E & LKS-16017E
KVM Control and Status: For LKS-8017E and LKS-16017E only 1. Computer Selection Pad: For an 8 port model, press one of these push buttons to select a computer. For a 16 port model, the 8 buttons can select either the lower bank 1-8 ports or the higher bank A-H ports. Ports 1 and A share the same push button. If port 1 is already selected, pressing 1 again will toggle between port A and port 1. If port 1 is not selected, press + hold push button 1 for 2 seconds to directly select port A. 2. Selected Computer Indicator: 2.1 1~8 Port: One of the indicators turns red when pushbuttons, hotkey or OSD menu selects a corresponding computer. 2.2 A~H Port: One of the indicators turns flashing red when pushbuttons, hotkey or OSD menu selects a corresponding computer. 3. Power on LED. 4. NOT IN USE 5. LCD Panel Menu: These buttons invoke the OSD menu for the LCD panel and acts as menu selection. 6. LCD Panel Adjustment: Lets you adjust settings for the LCD panel. 7. Num Lock: Keyboard Num Lock status. 8. Caps Lock: Keyboard Caps Lock status. 9. Scroll Lock: Keyboard Scroll Lock status. 10. LCD Panel Power Switch.
Page 5
ServerLink Eco KVM Rack Drawer
------------------------ Installation
Rack Cabinet
A complete ServerLink Eco KVM Rack Drawer with rear brackets installed is shown in Figure 6. Two kinds of rear brackets are available as options to fit rack cabinet of various depths as shown in Figure 7. Make sure you have the correct Rear Brackets that match the depth of your rack cabinet. Note: The type of the bracket is determined by the distance from the front side of the front vertical pole to the rear side of the rear vertical pole of the rack cabinet.
Figure 6: A complete ServerLink Eco KVM Rack Drawer
RW-1( 385mm long )
RW-2 ( 575mm long )
Figure 7: Rear Bracket pairs of different length
Cabinet’s RW-1* RW-2** Front Pole to Rear Pole Distance mm mm Minimum 400 590 Maximum 770 960 * RW-1 (385mm long) is an optional order. **RW-2 (575mm long) is included with the standard packaging.
Page 6
ServerLink Eco KVM Rack Drawer z
Install the Unit on the Rack a. Slide the bracket into both sides of the unit as shown in Figure 8. Make sure the three wheels are inside the track of the bracket while sliding.
Figure 8: Slide the Bracket into Both Sides of the Unit b.
Using standard cabinet screws, fasten both sides, front and back, to the rack.
Figure 9 : Screw Up the Unit on the Rack
Page 7
ServerLink Eco KVM Rack Drawer
Device Connection for LKS-1017E To a USB computer: Connect the standard VGA cable and a USB A-B cable to the computer and LKS-1017E as shown in Figure 6a. The computer can be a USB-ready PC, Sun, HP server, or a Mac.
Figure 6a: LKS-1017E with USB Computer Connection Diagram To a PS/2 computer: Connect the standard VGA cable and two mini-DIN6 male-to-male cables to the computer and LKS-1017E, see Figure 6b. There are two mini-DIN6 female connectors marked with keyboard and mouse, be sure not to swap the connections.
Figure 6b: LKS-1017E with PS/2 Computer Connection Diagram
Page 8
ServerLink Eco KVM Rack Drawer
Device Connection for LKS-8017E & LKS-16017E Use only the special cables as shown in Figure 5a and 5b.
Figure 5a: For PS/2 computers
Figure 5b: For USB computers
Connection from a ServerLink Eco KVM Rack Drawer to a PS/2 computer or a USB computer is shown in Figure 6.
Figure 6: Connections for the special cables
Initial Power-Up Make sure all computers and the Rack Drawer are powered down during installation. You must power up the Rack Drawer before turning on any other devices.
For single Rack Drawer: 1) 2)
Apply power to the ServerLink Eco KVM Rack Drawer. Turn on computers.
For the Rack Drawer in cascaded mode: 1)
Apply power to the ServerLink Eco KVM Rack Drawer.
2)
Apply power to all Slaves.
3)
Turn on computers.
Note: You may hot plug additional powered-down computers or a KVM Switch without turning any existing KVM switches or computers off after initial power up.
Page 9
ServerLink Eco KVM Rack Drawer
------------------------ Operation Push Buttons A computer may be selected by pressing the push button directly, by issuing hotkey commands or by activating the OSD window. The indicator changes to reflect the computer port selected (red). The indicator flashes red when it is in either Auto Scan or Manual Scan mode. Note: For a 16-port model: 1 ~ 8 represent the lower 8 ports and A ~ H for the higher 8 ports. Push the same button twice for higher 8 ports, for example, push button 1 twice for A port, and so forth.
K/M RESET
K/M RESET solves most problems developed by keyboard, mouse, device replacement or change of configuration. Press down both the front-panel number 1 and 2 push buttons for 2 seconds to re-configure the whole system without turning either the Rack Drawer or any computer off.
AUTO SCAN
The ServerLink Eco KVM Rack Drawer provides the easy to use feature to start Auto Scanning. Press down both the front-panel number 7 and 8 buttons for 2 seconds to start Auto Scanning.
Page 10
ServerLink Eco KVM Rack Drawer
OSD (On-Screen-Display) Operation
Figure 16: OSD screen illustration By hitting the left CTRL key twice within two seconds, you may see the 'Hotkey Menu' if it is enabled (an OSD option). Or, by hitting the left CTRL key three times within two seconds, you will see a 'KVM MENU' screen showing a list of the computers with corresponding port numbers, names and status, see Figure 16. The port number of the currently selected computer is displayed in red, same as the front indicator, at the right corner of the OSD menu. The color of a device name is green if it has power and is ready for operation, or the color is white as it has no power. The OSD menu updates the color when it is activated. Pressing the PageUp and PageDown keys to view 8 other computers. Use the “ Ï “, “ Ð “, “ 1 “ ~ “ 8 “ or “ A “ ~ “ H “ to highlight a Page 11
ServerLink Eco KVM Rack Drawer computer and the ENTER key to select it. Or, you may press ESCAPE to exit OSD and remove the OSD menu from the display; the status window returns to the display and indicates the currently selected computer or operating status. A triangle mark () to the right of a name indicates the port is cascaded to a Slave; the number at the left of the triangle mark shows the number of ports the Slave has, i.e. 8for an 8-port Switch. ENTER key brings you one level down and another screen pops up listing the names of the computers on that Slave. The name of the Slave will be shown at the upper right corner of the OSD menu. It is useful to group computers and still be able to see the group name. An eye mark (1) to the right of a name indicating the computer is selected to be monitored in Scan mode. In OSD, this mark can be switched on or off by function key F2 . Press ESCAPE key to exit OSD and to return to the selected computer; the computer name is also shown on the screen. Function key F1 : To edit name entry of a computer or a Slave with up to 14 characters. First, highlight a port then press F1 followed by name entry. Valid characters are ‘A’~’Z’, ‘0’~’9’, and the dash character. Lowercase letters are converted to uppercase ones. Press BACKSPACE to delete a letter one at a time. Non-volatile memory stores all name entries until you change, even if the unit is powered down. Function key F2 : To switch the eye mark (1) of a computer on or off. First, use the UP and DOWN arrow keys to highlight it, then press F2 to switch its eye mark on or off. If Scan Type is 'Ready PC +1', only the power-on and eye mark selected computers will be displayed sequentially in Scan mode. Function key F3 : To lock a computer from unauthorized access. To lock a device, highlight it then press F3 . Now, enter up to 4 characters (‘A’~’Z’, ‘0’~’9’, ‘-‘) followed by ENTER as new password. A Security-enabled device is marked with a lock (±) following its port number. To permanently disable the security function from a locked device, highlight it, press F3 then enter the password.
Page 12
ServerLink Eco KVM Rack Drawer If you want to access the locked device temporarily, simply highlight it and press ENTER , the OSD will ask you for the password. After entering the correct password, you are allowed to use the device. This device is automatically re-locked once you switch to another port. During Scan mode, OSD skips the password-protected devices. If you forget the password, the only way to permanently erase all the passwords is to: For 8-port and 16-port, press and hold the front panel buttons “1” and “2”, then hold “7” and “8”. Release “7” and “8”, then release “1” and “2”.
Function key F4 : More functions are available by hitting F4 . A new screen pops up displaying more functions as described below. Most of them are marked with a triangle () indicating there are options to choose from. Using the UP and DOWN arrow keys, select the functions and press ENTER . Available options will be shown in the middle of the screen. Again, using the UP and DOWN arrow keys to view options then press ENTER to select it. You can press ESCAPE to exit at any time.
Auto Scan In this mode, the ServerLink Eco KVM Rack Drawer automatically switches from one power-on computer to the next sequentially in a fixed interval. During Auto Scan mode, the OSD displays the name of the selected computer. When Auto Scan detects any keyboard or mouse activity, it suspends the scanning till the activity stops; it then resumes with the next computer in sequence. To abort the Auto Scan mode, press the left CTRL twice, or, press any front button. Scan Type and Scan Rate set the scan pattern. Scan Type ( F4 :More\Scan Type) determines if scanned computers must also be eye mark selected. Scan Rate ( F4 :More\Scan Rate) sets the display interval when a computer is selected before selecting the next one.
Page 13
ServerLink Eco KVM Rack Drawer
Manual Scan Scan through power-on computers one by one using keyboard control. Scan Type ( F4 :More\Scan Type) determines if scanned computers must also be eye mark selected. Press the up arrow key (Ï) to select the previous computer and the down arrow key (Ð) to select the next computer. Press any other key to abort the Manual Scan mode.
Scan Type Ready PC +1: In Scan mode, scan through power-on and eye mark selected computers. Ready PC: In Scan mode, scan through power-on computers.
1 Only: In Scan mode, scan through any 1 selected computer regardless of computer power status. The non-volatile memory stores the Scan Type setting.
Scan Rate Sets the duration of a computer displayed in Auto Scan mode. The options are 3 seconds, 8 seconds, 15 seconds and 30 seconds. The non-volatile memory stores the Scan Rate setting.
PS/2 Keyboard Speed The ServerLink Eco KVM Rack Drawer offers keyboard typematic setting that overrides the similar settings in BIOS and in Windows. Available speed options are Low, Middle, Fast and Faster as 10, 15, 20 and 30 characters/sec respectively. The non-volatile memory stores the Keyboard Speed setting.
Hotkey Menu When you hit the left CTRL key twice within two seconds, the "Hotkey Menu" appears displaying a list of hotkey commands if the option is On. The 'Hotkey Menu' can be turned Off if you prefer not to see it when the left CTRL key is hit twice. The non-volatile memory stores the Hotkey Menu setting.
CH Display Auto Off: After you select a computer, the port number and name of the computer will appear on the screen for 3 seconds then disappear automatically. Always On: The port number and name of a selected computer and/or OSD status displayed on the screen all the time. The Page 14
ServerLink Eco KVM Rack Drawer non-volatile memory stores the CH Display setting.
Position The position of the selected computer name and/or OSD status displayed on screen during operation, the actual display position shifts due to different VGA resolution, the higher the resolution the higher the display position. The non-volatile memory stores the Position setting. Upper Left, Upper Right, Lower Left, Lower Right. Middle. ESC: To exit the OSD, press the ESCAPE
key.
Hotkey commands Hotkey command is a short keyboard sequence to select a computer, to activate computer scan, etc. The ServerLink Eco KVM Rack Drawer interprets keystrokes for hotkeys all the time. A hotkey sequence starts with two left CTRL keystrokes followed by one or two more keystrokes. A built-in buzzer generates a high-pitch beep for correct hotkey command; otherwise, one low-pitch beep for error and the bad key sequence will not be forwarded to the selected computer.
The short form hotkey menu can be turned on as an OSD function ( more\Hotkey Menu) every time the left CTRL key is pressed twice.
F4
:
Left Ctrl : is the CTRL key located at the left side of the keyboard. 1~8/A~H: are the number keys '1' ~ '8' at the upper row of the keyboard and character keys 'A' ~ 'H' are case insensitive. Do not use the keypad at the right of the keyboard.
To select a computer by hotkey command, you must know its port number, which is determined by the connection. For a computer connected to a (Master), its port is represented by the PC port label (1~8 or A~H). For a computer connected to a Slave, two characters represent its port. The first character is the port number on the Rack Drawer (1~8) and the Page 15
ServerLink Eco KVM Rack Drawer second one is the port number on the Slave (1~8 or A~H). Please note that only 'PC 1' ~'PC 8' ports on a ServerLink Eco KVM Rack Drawer can be connected to a Slave. left Ctrl + left Ctrl + 4 Selects a computer connected to port 4 of the Rack Drawer (Master). left Ctrl + left Ctrl + 3 + C Selects a computer connected to port C of a Slave connected to port 3 of the Rack Drawer.
To start Auto Scan, automatically scan power-on computers one by one at a fixed interval: left Ctrl + left Ctrl + F1 When Auto Scan detects any keyboard or mouse activity, it suspends the scanning till the activity stops; it then resumes with the next computer in sequence. The length of the Auto Scan interval (Scan Rate) is adjustable, see below. To abort the Auto Scan mode, press the left Ctrl key twice. Note: Scan Type determines whether an eye-marked computer is to be displayed during Auto Scan.
Manual Scan enables you to manually switch back and forth between power-on computers. left Ctrl + left Ctrl + F2 Press Ï or Ð to select the previous or the next computer in sequence. And, press any other key to abort the Manual Scan. Note: Scan Type determines whether an eye-marked computer is to be displayed during Auto Scan.
To adjust Scan Rate which sets the duration before switching to the next computer in Auto Scan: left Ctrl + left Ctrl + F3 The Rack Drawer sends one to four beeps indicating scan interval of 3, 8, 15 and 30 seconds respectively.
To adjust keyboard typematic rate (characters/sec), this setting over-rides that of BIOS and any operating system: left Ctrl + left Ctrl + F4 The Rack Drawer generates 1 to 4 beeps corresponding to 10, 15, 20 and 30 characters/sec respectively. (For PS/2 keyboard only)
Page 16
ServerLink Eco KVM Rack Drawer
-------------------- Cascade Configuration Connection Before connecting a device (a computer or a Slave KVM Switch) to the Rack Drawer under power, you must turn off the device. Note: The ServerLink Eco KVM Rack Drawer must have equal or more ports than that of the Slave, i.e., if the Master has an 8-port KVM switch, another 8-port KVM switch can be a Slave, but not a 16-port one. The ports labeled "PC 1"~”PC 8” can be connected to either a computer or a Slave's CONSOLE port, as shown in Figure 17. The ports “PC A"~”PC H” can only be connected to computers.
Figure 17: Slave console connection . The maximum number of computers controlled by a master/slave configuration with all 8-port units is 64 -- with 8 Slaves and each Slave connects to 8 computers, see Figure 18.
Page 17
ServerLink Eco KVM Rack Drawer
Figure 18: The Rack Drawer and 8-port KVM Switches in cascade
For OSD menu: After connection completes, you should re-activate the OSD menu to check if the Master recognizes the Slaves. A triangle mark () is placed to the right of the channel name indicating the port is connected to a Slave not a computer. A number to the left of the triangle mark indicates the Slave model, i.e. 8 for an 8-port Switch.
Change Configuration while Running A device (a computer or a KVM Switch) at any 'PC x' port can be changed at any time after initial power-up. If you change any one of the “PC 1” to “PC 8” connection from a computer to a Slave or vice versa, or replace the devices of a port; the OSD will update this change the next time it is activated. Note: Any new device must be turned off before it is connected to the Rack Drawer.
Page 18
ServerLink Eco KVM Rack Drawer
------------------------ Appendices Specifications: Specifications
LKS-1017E
LKS-8017E
LKS-16017E
No. of users
1
1
1
No. of computers
1
8
16
No. of cascadable computers
Up to 16
Up to 64*
Up to 136*
Available cable type
USB or PS/2
Applicable to computer
3-in-1, HDB15 for PS/2 or USB PS/2 PC, USB PC, Sun†, Mac
Included cables
None
On-screen display (OSD)
No
Yes
Push button control
No
8, available when connected to a KVM drawer
Hot plug-and-play Hotkey control
Yes No
Yes
Rack-mounted
Yes, 19” industry-standard
Automatic scan interval
No
3, 8, 15, 30 seconds
Programmable scan pattern
No
Yes
Cable length (Max) Device connectors
Keyboard Mouse Monitor
15M at PC ports for PS/2 5M at PC ports for USB 1 x USB 2 x PS/2 1 x HDB-15 male
8 x HDB-15 female
H x W x D (mm) (in.)
40 x 404 x 114 1.6 x 15.9 x 4.5
Rear-mount brackets
1U-height, included
size
1U
* Maximum control when cascaded with models of the same type. † For USB-ready Sun computers.
Page 19
16 x HDB-15 female
ServerLink Eco KVM Rack Drawer
LCD Panel Specification: Specification LCD Size
17” TFT
Active Display Area
337.920 x 270.336 (mm)
Pixel Pitch (mm)
0.264(H) x 0.264(V)
Resolution
1280 x 1024
Brightness
260 cd/m
Contrast Ratio
450:1
Display Color
16.2M (8 bits/color)
Viewing Angle
- 80~ 80(H)
2
- 80~ 80(V)
Video/Keyboard/Mouse Specification: User Control
OSD Control (auto saving)
Input Signal
RGB analog, H/V separate
Plug-n-Play VESA
VESA DDC 1/2B
Power Consumption
33W typical, normal operation
Power Management
VESA DPMS compliant “on” mode: 23.2W “stand-by” mode <= 1W “suspend” mode <= 1W “off” mode <= 1W
Scanning Frequency
H:30-68Khz;V:50-75Hz
Keyboard
105 Key, PS/2
Mouse Touch Pad
PS/2
Note: It is suggested to set the VGA resolution for all the computers to “1024 x 768” with “Large Fonts” in order to achieve the best performance for the TFT LCD panel.
Page 20
ServerLink Eco KVM Rack Drawer
Troubleshooting: Ensure that all cables are well seated. Check that keyboard/mouse cables are not swapped. Label and bundle the cables for each computer to avoid confusion when connected to the ServerLink Eco KVM Rack Drawer.
Symptom
Possible causes
Nothing works
No power
Recommended solutions
VGA monitor works fine but keyboard and touch pad does not work.
Another keyboard or mouse is Remove the external keyboard and connected to the rear side of mouse. The local port is only used for the KVM Module box (marked trouble shooting or diagnostics. with Local).
Connect the power cable, turn on the TFT LCD panel and press one of the buttons near the right side of the keyboard to pop up the OSD of the TFT LCD panel. If the OSD pops up, the drawer works.
No screen A power-on computer is not Turn on a computer and select it by the front push buttons image, or no selected OSD menu External power supply is not Apply power to the system. Press the connected. There is no power front push buttons to select a computer. A red rectangle, part of the OSD to system function, should pop up displaying the port number as the system is properly powered. Connect a VGA monitor to the LOCAL port and check if the VGA signal presents. Both TFT LCD monitor and an external VGA monitor should have the same video image.
Alphabets on Improper resolution settings the TFT LCD display are blurring or have shadows. I forget the Bad memory password
Master/slave does not work
Improper installation procedures
Set the VGA resolution of the computers to 1024 x 768 with “Large Font” for the best performance. Hold down pushbuttons 1 and 2, then 7 and 8. Release 7 and 8 then release 1 and 2. Memorize the password Make sure slave’s CONSOLE is connected to Master’s PC 1~ PC 8 port. Only PS/2 ports can be used for cascade connection.
Page 21
ServerLink Eco KVM Rack Drawer Press and hold the 1 and 2 push buttons to initiate K/M reset Remove any possible power supply to the slave (unplug all cables), before connecting it to the Master Press both SHIFT keys
Keyboard strokes shifted
The computer was in shifted state when last switched
The Ï and Ð keys do not work in Manual Scan
All PCs are off or only one PC Turn computers on. is turned on. Scan mode works for power-on computers Press any other key to abort Manual Scan mode. only Scan type is eye mark selected but no PC is eye mark selected in OSD. All PCs are off or only one PC is turned on. Scan mode works for power-on computers only
Auto Scan does not switch port and the system beeps from time to time and red Scan type is eye mark indicator selected but no power-up PC flashes is eye mark selected in OSD.
Set proper Scan type in OSD and determine which PCs are eye marks selected, do it in OSD. Turn on computers Set proper Scan Type in OSD and determine which PCs are eye marks selected, do it in OSD. Press left CTRL key twice to abort Auto Scan mode. Press any front button to select a PC, and Auto Scan stops
Double OSD images at cascade configuration
Improper slave connection procedure.
Hold pushbuttons 1 and 2 down for 2 seconds to activate K/M RESET
Remove any possible power supply to the Slave (unplug all cables), before connecting it to the system OSD menu is OSD menu has fixed Use F4 :More\Position to select UL not at the resolution. Its size varies and or UR. OSD menu may appear near proper position position shifts as computer the middle of the screen when LL or LR VGA resolution changes. is selected. Only ports PC1~PC8 of the system can Can not select a Improper cable connection be connected to slaves. computer connected to a Connect slave CONSOLE port to Improper slave unit slave PC1~PC8 ports of the system connection Too many levels of slaves
Only one level of slave units is allowed. Pop up OSD again to check if the system recognizes the slave connection. Look for triangle mark and the number before it to verify the connection.
Page 22
ServerLink Eco KVM Rack Drawer
Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR'S LIABILITY FOR DIRECT OR INDIRECT, SPECIAL, INCIDENTIAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFIT, LOSS OF BUSINESS, OR FINANCIAL LOSS WHICH MAY BE CAUSED BY THE USE OF THE PRODUCT EXCEEDS THE PRICE PAID FOR THE PDOCUDT. The direct vendor makes no warranty or representation, expressed or implied with respect to the contents or use of this documentation, and especially disclaims its quality, performance, merchantability, or fitness for any particular purpose. The direct vendor also reserves the right to revise or update the product or documentation without obligation to notify any user of such revisions or updates. For further information, please contact your direct vendor. All the brand names and registered trademarks are the property of their respective owners.
PP5-ILN5900-000-JD Printed in Taiwan
Page 23