Preview only show first 10 pages with watermark. For full document please download

Talexxmodule Stark Qle Classic Em En

   EMBED


Share

Transcript

U – LED modules, converters and systems GENERAL ILLUMINATION Umodule STARK QLE CLASSIC EM umodule STARK QLE Product description • Ideal for linear and panel lights OU T • Combined LED module for general and emergency lighting • Integrated separate emergency LEDs controlled by EM powerLED (2 or 4 W version) • Efficiency of the module up to 106 lm/W • Separate wired emergency LEDs • High colour rendering index CRI > 80 • Small colour tolerance MacAdam 44 • Small luminous flux tolerances 270 222 • Perfectly uniform light, even if several LED modules EM_In(+) are used together in a line • Self-cooling (no additional heat sink required) EM_Out(-) module SE D • Push terminals for quick and simple wiring of LED module to LED • Simple installation (e.g. screws) • Long lifetime: 50,000 hours tp 180 270 • Colour temperatures 3,000 and 4,000 K Ø4 • 5-year system guarantee on the complete product Technical data Beam characteristic Ambient temperature ta Typ. tp point 120° Ordering data -30 ... +55 °C Type Article number Colour temperature Packaging, carton Weight per pcs. STARK-QLE-1250-830-CLA-EM 25000817 3,000 K 40 pieces 0.135 kg STARK-QLE-1250-840-CLA-EM 25000819 4,000 K 40 pieces 0.135 kg 65 °C Risk group (EN 62471:2008) 0 Type of protection IP00 È PH A Standards, page 3 D For colour temperatures and tolerances, page 6 Specific technical data Type Photometric code Typ. luminous flux1 Typ. forward current1 2 3 Typ. forward voltage Typ. power Luminous efficacy Luminous efficacy Colour rendering module system index CRI consumption1 Mains mode STARK QLE-1250-830-CLA EM 830/4x9 1,190 lm 350 mA 33.7 V 11.8 W > 101 lm/W ~ 93 lm/W > 80 STARK QLE-1250-840-CLA EM 840/4x9 1,250 lm 350 mA 33.7 V 11.8 W > 106 lm/W ~ 98 lm/W > 80 STARK QLE-1250-830-CLA EM 830/4x9 230 lm 350 mA 6.2 V – – – – STARK QLE-1250-840-CLA EM 840/4x9 245 lm 350 mA 6.2 V – – – – STARK QLE-1250-830-CLA EM 830/4x9 430 lm 700 mA 6.2 V – – – – STARK QLE-1250-840-CLA EM 840/4x9 455 lm 700 mA 6.2 V – – – – Emergency mode – 350 mA (EM powerLED 2 W) Emergency mode – 700 mA (EM powerLED 4 W) All values at tc = 65 °C. 1 Tolerance 2 Ripple 3 Max. range for optical and electrical data: ±10 %. max. 15 % of rated current. permissible surge current: 1.5 A, duration max. 10 µs. 4 Integrated measurement over the complete module. Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 1 U – LED modules, converters and systems GENERAL ILLUMINATION Converter matrix – Umodule STARK QLE CLASSIC IN-BUILT LCI Type LCAI 080/0350 I010 LCI 080/0350 I010 LCI 050/1050 R010 LCI 055/1400 R010 86459392 86459366 86459216 86459217 series series parallel Ord. No. Circuit Voltage on the module (typ.) 135 V 202 V SELV 135 V 202 V No 33.7 V parallel 33.7 V No 33.7 V Yes 33.7 V Yes assignable converter STARK QLE-1250 Min. Max. Min. Max. Min. Max. Min. Max. 4 6 4 6 3 3 4 4 OU T Type Converter matrix – Umodule STARK QLE CLASSIC REMOTE LCI Type LCI 050/1050 T020 86459218 Ord. No. parallel Circuit Voltage on the module (typ.) 33.7 V SELV LCI 055/1400 T020 LCCI 016/0350 Q010 86459219 86459213 parallel 33.7 V Yes 33.7 V – 33.7 V 33.7 V Yes 33.7 V Yes assignable converter Type Min. Max. 3 3 Min. Max. Min. Max. 4 4 1 1 SE D STARK QLE-1250 Converter matrix – Umodule STARK QLE CLASSIC IN-BUILT LCI Type Ucontrol C350 dim Ucontrol C700 dim Ucontrol C350-2 4 Kanal 86458944 86458945 86458693 – parallel Ord. No. Circuit Voltage on the module (typ.) 33.7 V SELV 33.7 V 33.7 V Yes 33.7 V – 33.7 V Yes 33.7 V Yes assignable converter Type PH A STARK QLE-1250 Min. Max. Min. Max. Min. Max. 1 1 2 2 1 4 Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 2 U – LED modules, converters and systems GENERAL ILLUMINATION Standards EN 62031 EN 62471 EN 61347-1 EN 61547 EN 55015 Photometric code Key for photometric code, e. g. 830 / 449 2nd + 3rd digit 4th digit 5th digit 6th digit Lumen maintanance after 25% McAdams after of the lifetime (max.6000h) Code CRI Code Remaining lumen Colour temperature in McAdams 25% of the 7 67 – 76 7 ≥ 70 % lifetime Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 % OU T 1st digit Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK QLE will be greatly reduced or the umodule STARK QLE may be destroyed. SE D tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product. For umodule STARK QLE a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Mounting instruction PH A None of the components of the umodule STARK QLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. The LED modules are mounted with 4 screws per module. In order not to damage the modules only rounded head screws and an additional plastic flat washer should be used. EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 3 U – LED modules, converters and systems GENERAL ILLUMINATION Electrical supply/choice of converter umodule STARK QLE from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule STARK QLE guarantees the necessary protection for safe and reliable operation. Thermal behaviour storage temperature operating temperature ta tc max. (at typ. current) max. humidity -40 ... +85 °C -30 ... +55 °C 80 °C 0 ... 80 % If a converter other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection 800 700 umodule STARK QLE must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module. If [mA] 600 500 400 300 Wrong polarity can damage the umodule STARK QLE. 200 100 0 OU T 900 0 10 20 30 40 50 60 Tc [°C] 70 80 Lifetime 90 100 If umodules QLE are wired in parallel and a wire breaks or a complete module fails then the current passing through the other module increases. This may reduce its life considerably. In addition there can be slight differences in light output caused by tolerances. Wiring 65 luminous flux in % lifetime in h 80 70 50 30.000 50.000 90.000 in + EM_in (+) EM_out (–) SE D tc temperature in °C Selection of the control gear umodule STARK QLE can be operated either from 350mA SELV converters or from 350 mA converters with LV output voltage. For a maximised system efficacy LED controlgear with LV output (e.g. LCAI 080/0350) are recommended. These LED controlgear are designed for an efficiency > 90 % where LED control gear with SELV outputvoltage (e.g. LCI 050) can be delivered with an efficiency > 83 %. PH A umodule STARK QLE are basic isolated against ground and can be mounted directly on earthed metal parts of the luminaire also when used in conjunction with the converter LCAI 080/0350. In this case the light emitting side of the module has to be protected against direct touch (test finger). This is typically achieved by means of a non removable light distributor over the module. out – Wiring examples 230 – 240 V AC 0/50/60 Hz L N PE Umodules STARK QLE Uconverter LCAI 80 W 350 mA + – 2 3 4 + – Permanentline + – + – + + – – + – + – Akku EM PowerLED 4W Umodule STARK QLE EM Wiring type and cross section The wiring can be solid cable with a cross section of 0.4 to 0.75 mm². For the push-wire connection you have to strip the insulation (6–7 mm). Loosen wire through twisting and pulling. wire preparation: 0.4 – 0.75 mm² 6 – 7 mm Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 4 U – LED modules, converters and systems GENERAL ILLUMINATION 1,05 1,10 1,04 1,00 1,03 rel. luminous flux [a.u.] relative voltage [a.u.] Relative forward voltage and relative luminous flux 1,02 1,01 1 0,80 0,70 0,60 OU T 0,99 0,90 0,98 0,50 0,97 20 30 40 50 Tc [°C] 60 75 70 The diagrams based on statistic values. The real values can be different. 25 35 45 Tc [°C] 55 65 75 SE D Optical characteristics Umodule STARK QLE The optical design of the umodule STARK QLE product line ensures optimum homogenity for the light distribution. Light distribution -20° -40° 10° -50° 60 -60° The colour temperature is measured integral over the complete module. The single LED light points can have deviations in the colour coordinates within MacAdam 7. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 6 cm) should be used. 20° 30° 40° 50° 60° PH A relative intensity Iv/Iv, max 0° -30° 100 80 -10° 40 70° 80° 20 0 -100 -80 -60 -40 -20 0 20 40 60 80 100 90° 3D-Data, photometric data and Design-in guide available on request or go to www. tridonic.com Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 5 U – LED modules, converters and systems GENERAL ILLUMINATION Coordinates and tolerances according to CIE 1931 The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K x0 0,4344 Centre y0 0,4032 0,4250 100 norm. intensity [%] 0,4150 0,4100 0,4050 0,4000 0,3950 80 60 40 20 0,3900 0,4550 0,4500 0,4450 0,4400 0,4350 0,4300 0,4250 0,4150 0,4200 0,3850 OU T 0,4200 MacAdam Ellipse: 4SDCM 0 380 420 460 500 540 580 620 660 wave length [nm] 700 740 780 500 540 580 620 660 wave length [nm] 700 740 780 4,000 K y0 0,3803 SE D x0 0,3828 Mittelpunkt 100 0,4000 0,3950 80 norm. intensity [%] 0,3900 0,3850 0,3800 0,3750 0,3700 0,4000 0,3950 0,3900 0,3850 0,3800 0,3750 0,3700 0,3650 PH A 0,3600 0,3600 40 20 0,3650 60 0 380 420 460 MacAdam Ellipse: 4SDCM Data sheet 08/12-LED098-4 Subject to change without notice. www.tridonic.com 6