Preview only show first 10 pages with watermark. For full document please download

Talexxmodule Stark Sle Gen2 Classic En

   EMBED


Share

Transcript

LED light engine / OLED LED compact Umodule STARK SLE GEN2 CLASSIC STARK SLE Product description T • For spotlights and downlights • High efficiency up to 145 lm/W for the LED module • High system efficiency up to 115 lm/W at tp = 65 °C U • High colour consistency (MacAdams 3) angle for spotlights • Excellent thermal management by COB technology • NTC for temperature control for type LES23 and LES26 • Fixing holes for M3 screws • Cooling required LES 23 7,2 LES 19 • Built-in LED module Ø50 35 Ø19 • Long life time: up to 80 % luminous flux after 50,000 operating 7,2 O • Uniform radiation with Dam&Fill technology LES 26 Ø50 35 Ø23 7,2 • Small LES (light emitting surface) diameter enables small beam Ø50 35 Ø26 Colour temperatures and tolerances, page 12 ø3,3 Ø3,2 □31 1,75 tc/tp 3,13 □31 tc/tp ø3,3 Ø26 3,13 Standards, page 5 1,75 tc/tp 22,5 È □31 LES 26 1,2 ±0,5 1,65 ±0,15 1,75 1,65 ±0,15 IP00 LES 23 22,5 Type of protection LES 19 1,2 ±0,5 1 Ø23 3,13 65 °C Risk group (EN 62471:2008) 1,65 ±0,15 tp_rated temperature1 With housing (tc/tp position same as without housing) 22,5 -25 ... +55 °C 1,2 ±0,5 140° Ambient temperature ta AS E Beam characteristic Ø19 3,13 Technical data Ø3,2 Ø3,2 • Flexible operating modes D hours 3,13 ø3,3 3,13 Without housing Ordering data PH Type Colour Connection Housing Packaging temperature cable Weight per pc. STARK SLE G2 LES19 830 CLA 89601652 3,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES19 840 CLA 89601632 4,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES19 750 CLA 89601633 5,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES23 830 CLA 89601634 3,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES23 840 CLA 89601635 4,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES23 750 CLA 89601636 5,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES26 830 CLA 89601637 3,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES26 840 CLA 89601638 4,000 K yes no 15 pc(s). 0.008 kg STARK SLE G2 LES26 750 CLA 89601639 5,000 K STARK SLE PURE G2 LES19 830 CLA 89601622 3,000 K yes no 15 pc(s). 0.008 kg no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES19 840 CLA 89601623 4,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES19 750 CLA 89601624 5,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES23 830 CLA 89601625 3,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES23 840 CLA 89601626 4,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES23 750 CLA 89601627 5,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES26 830 CLA 89601628 3,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES26 840 CLA 89601629 4,000 K no yes 20 pc(s). 0.010 kg STARK SLE PURE G2 LES26 750 CLA 89601630 5,000 K no yes 20 pc(s). 0.010 kg Data sheet 06/13-LED100-10 Subject to change without notice. Article number www.tridonic.com 1 LED light engine / OLED LED compact Specific technical data Type7 Photometric Forward Luminous flux Luminous code at flux at current3 4 5 tp = 25 °C2 tp = 65 °C2 Power consumption module8 Forward voltage module6 8 Luminous Luminous Luminous Colour efficacy module efficacy module efficacy system rendering at tp = 25 °C at tp = 65 °C at tp = 65 °C index CRI Energy classification STARK SLE LES19 – Operating mode HE at 350 mA STARK SLE G2 LES19 830 CLA 830/349 350 mA 1,450 lm 1,250 lm 11.6 W 33.2 V 125 lm/W 108 lm/W 97 lm/W 80 A+ STARK SLE G2 LES19 840 CLA 840/349 350 mA 1,600 lm 1,400 lm 11.6 W 33.2 V 138 lm/W 121 lm/W 109 lm/W 80 A++ STARK SLE G2 LES19 750 CLA 750/349 350 mA 1,750 lm 1,500 lm 11.6 W 33.2 V 142 lm/W 125 lm/W 113 lm/W 70 A++ STARK SLE LES19 – Operating mode NM at 500 mA STARK SLE G2 LES19 830 CLA 830/349 500 mA 2,000 lm 1,750 lm 17.1 W 34.2 V 117 lm/W 102 lm/W STARK SLE G2 LES19 840 CLA 840/349 500 mA 2,250 lm 1,900 lm 17.1 W 34.2 V 132 lm/W 112 lm/W 101 lm/W 80 A+ STARK SLE G2 LES19 750 CLA 750/349 500 mA 2,400 lm 2,100 lm 17.1 W 34.2 V 135 lm/W 117 lm/W 105 lm/W 70 A++ 80 A+ T STARK SLE LES19 – Operating mode HO at 700 mA 92 lm/W 830/349 700 mA 2,700 lm 2,300 lm 24.7 W 35.3 V 109 lm/W 93 lm/W 84 lm/W 80 A+ 840/349 700 mA 3,000 lm 2,550 lm 24.7 W 35.3 V 121 lm/W 103 lm/W 93 lm/W 80 A+ STARK SLE G2 LES19 750 CLA 750/349 700 mA 3,250 lm 2,800 lm 24.7 W 35.3 V 126 lm/W 107 lm/W 96 lm/W 70 A+ STARK SLE LES23 – Operating mode HE at 500 mA 830/349 500 mA 2,100 lm 1,800 lm 16.5 W 33.1 V 840/349 500 mA 2,300 lm 2,000 lm 16.5 W 33.1 V STARK SLE G2 LES23 750 CLA 750/349 500 mA 2,500 lm 2,150 lm 16.5 W 33.1 V 127 lm/W 109 lm/W 98 lm/W 80 A+ 139 lm/W 121 lm/W 109 lm/W 80 A++ 145 lm/W 127 lm/W 115 lm/W 70 A++ O STARK SLE G2 LES23 830 CLA STARK SLE G2 LES23 840 CLA U STARK SLE G2 LES19 830 CLA STARK SLE G2 LES19 840 CLA STARK SLE LES23 – Operating mode NM at 700 mA STARK SLE G2 LES23 830 CLA 830/349 700 mA 2,850 lm 2,450 lm 23.8 W 33.9 V 120 lm/W 103 lm/W 93 lm/W 80 A+ STARK SLE G2 LES23 840 CLA 840/349 700 mA 3,150 lm 2,700 lm 23.8 W 33.9 V 132 lm/W 113 lm/W 102 lm/W 80 A+ STARK SLE G2 LES23 750 CLA 750/349 700 mA 3,400 lm 2,950 lm 23.8 W 33.9 V 137 lm/W 118 lm/W 106 lm/W 70 A++ STARK SLE LES23 – Operating mode HO at 1,050 mA 830/349 1,050 mA 4,050 lm 3,500 lm 37.1 W 35.3 V 109 lm/W 94 lm/W 85 lm/W 80 A+ 840/349 1,050 mA 4,450 lm 3,850 lm 37.1 W 35.3 V 120 lm/W 104 lm/W 93 lm/W 80 A+ STARK SLE G2 LES23 750 CLA 750/349 1,050 mA 4,850 lm 4,200 lm 37.1 W 35.3 V 124 lm/W 108 lm/W 97 lm/W 70 A+ STARK SLE LES26 – Operating mode HE at 700 mA D STARK SLE G2 LES23 830 CLA STARK SLE G2 LES23 840 CLA STARK SLE G2 LES26 830 CLA 830/349 700 mA 2,950 lm 2,500 lm 23.2 W 33.2 V 127 lm/W 108 lm/W 97 lm/W 80 A+ STARK SLE G2 LES26 840 CLA 840/349 700 mA 3,250 lm 2,800 lm 23.2 W 33.2 V 140 lm/W 121 lm/W 109 lm/W 80 A++ STARK SLE G2 LES26 750 CLA 750/349 700 mA 3,500 lm 3,000 lm 23.2 W 33.2 V 144 lm/W 125 lm/W 113 lm/W 70 A++ AS E STARK SLE LES26 – Operating mode NM at 1,050 mA STARK SLE G2 LES26 830 CLA 830/349 1,050 mA 4,200 lm 3,650 lm 36.0 W 34.3 V 117 lm/W 101 lm/W 91 lm/W 80 A+ STARK SLE G2 LES26 840 CLA 840/349 1,050 mA 4,650 lm 4,000 lm 36.0 W 34.3 V 129 lm/W 111 lm/W 100 lm/W 80 A+ STARK SLE G2 LES26 750 CLA 750/349 1,050 mA 5,050 lm 4,350 lm 36.0 W 34.3 V 133 lm/W 115 lm/W 104 lm/W 70 A++ STARK SLE LES26 – Operating mode HO at 1,400 mA STARK SLE G2 LES26 830 CLA 830/349 1,400 mA 5,400 lm 4,650 lm 49.5 W 35.3 V 109 lm/W 94 lm/W 85 lm/W 80 A+ STARK SLE G2 LES26 840 CLA 840/349 1,400 mA 5,950 lm 5,100 lm 49.5 W 35.3 V 120 lm/W 103 lm/W 93 lm/W 80 A+ STARK SLE G2 LES26 750 CLA 750/349 1,400 mA 6,450 lm 5,550 lm 49.5 W 35.3 V 124 lm/W 107 lm/W 96 lm/W 70 A+ 1 If the max, temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged, The temperature of the umodule at the tp-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1, For the precise position of the tp point see the drawing above. 2 Tolerance range for optical data: ±10 %. the max, operating current leads to an overload on the umodule, This may in turn result in a significant reduction in lifetime or even destruction of the umodule. 3 Exceeding 4 Max. permissible surge current: 3 A, duration max. 10 µs. max. 50 % of typ. forward current. PH 5 Ripple 6 Tolerance range voltage: ±10 %. 7 HE ... high efficiency, NM ... nominal mode, HO ... high output. 8 All values at tp = 65 °C. Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 2 LED light engine / OLED LED compact LED control gear matrix – Umodule STARK SLE G2 REMOTE Type Article no. IN-BUILT LCAI 015/0350 A020 LCI 015/0350 E020 LCCI 016/0350 B020 86458899 24166312 86459210 LCI 015/0350 M020 LCI 20W 350mA TEC SR LCCI 016/0350 Q010 LCI 20W 350mA TEC C 86459179 87500187 86459213 87500079 G G G assignable control gear Type Operating mode at 350 mA G G G T G STARK SLE G2 REMOTE Article no. IN-BUILT LCI 20W 500mA TEC SR LCI 20W 500mA TEC C 87500189 87500188 86459107 assignable control gear Type Operating mode at 500 mA G G D G STARK SLE G2 O Type LCAI 020/0500 A120 one4all U LED control gear matrix – Umodule STARK SLE G2 LED control gear matrix – Umodule STARK SLE G2 REMOTE Article no.. Type LCAI 030/0700 A120 one4all LCI 030/0700 E020 LCI 033/0700 U010 LCI 35W 700mA TEC SR LCI 030/0700 M120 86458900 24166314 25000669 87500197 86459178 G G AS E Type LCI 030/0700 A120 86458901 assignable control gear Operating mode at 700 mA G STARK SLE G2 G G G LED control gear matrix – Umodule STARK SLE G2 REMOTE Type PH Article no. LCAI 050/1050 N020 DALI 24166469* IN-BUILT LCI 050/1050 N020 LCI 35W 700mA TEC C 24166468* 87500196 assignable control gear Type Operating mode at 700 mA STARK SLE G2 G G G * Configuratet for 700 mA, see control gear data sheet. Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 3 LED light engine / OLED LED compact LED control gear matrix – Umodule STARK SLE G2 REMOTE Type IN-BUILT LCAI 050/1050 N020 DALI LCI 050/1050 N020 LCI 050/1050 R010 LCI 050/1050 T020 LCI 60W 1050mA TEC SR LCAI 055/1400 O010 DALI LCI 055/1400 O010 LCI 60W 1050mA TEC C 24166469 24166468 86459216 86459218 87500203 24166471* 24166470* 87500202 G G G Article no. assignable control gear Type Operating mode at 1,050 mA G STARK SLE G2 G G G G U T * Configurated for 1,050 mA, see control gear data sheet. LED control gear matrix – Umodule STARK SLE G2 REMOTE Article no. LCI 055/1400 T020 LCI 65W 1400mA TEC SR LCAI 055/1400 O010 DALI 86459219 87500205 24166471 LCI 055/1400 O010 LCI 055/1400 R010 O Type IN-BUILT 24166470 86459217 G G assignable control gear Type Operating mode at 1,400 mA G G G PH AS E D STARK SLE G2 Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 4 LED light engine / OLED LED compact Standards EN 62031 EN 62471 EN 61547 EN 55015 IEC 62717 Mounting instruction umodule STARK SLE G2 from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. None of the components of the umodule STARK SLE G2 (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Photometric code Max. torque for fixing: 0.5 Nm. Key for photometric code, e. g. 830 / 349 For further information please refer to to the brochure entitled “Technical Design-In-Guide SLE GEN2”. 4th digit 6th digit Luminous flux after 25% McAdams after of the lifetime (max.6000h) Code CRI Code Luminous flux Colour temperature in McAdams 25% of the 7 67 – 76 7 ≥ 70 % lifetime Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 % U 2nd + 3rd digit 5th digit The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp D Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK SLE G2 will be greatly reduced or the umodule STARK SLE G2 may be destroyed. EOS/ESD safety guidelines O 1st digit T Glow wire test according to EN 62031 with increased temperature of 960 °C passed. Temperature control for LES23 and LES26 An NTC resistor is on the board of the umodule STARK SLE G2 to control the tp temperature during the operation with a resistor value of 220 kΩ NTC. Therefore the umodule STARK SLE G2 needs to be mounted onto a heat sink heat sink which does not exceed the value for Rth,max. 240 PH tp point, ambient temperature and lifetime The temperature at tp reference point is crucial for the light output and life time of a u product. The opeating temperature of a Talex product is crucial for the light output, the product life time but also for the product safety. The thermal limits can be checked at the tp/tc point and at tr. On page 10 the lumen maintenance is shown in relation to the temperature at tp. tp,rated shows the temperature at which the rated values are reached. tc shows the thermal limit for safety reason und must never be exceeded under normal conditions. For the interchangeablity with othe Zhaga products, tr,max is specified directly at the thermal interface to the heatsink of the luminaire. For umodule STARK SLE G2 a tp temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tp point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. 220 200 180 160 Resistance [kΩ] AS E Tridonic’s excellent thermal design for the umodule STARK SLE G2 products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. 140 120 100 80 60 40 20 0 30 25 35 40 45 60 55 50 Temperature [°C] 65 70 75 80 85 Electrical supply/choice of LED control gear umodule STARK SLE G2 from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED control gear which complies with the relevant standards. The use of u LED control gears from Tridonic in combination with umodule STARK SLE G2 guarantees the necessary protection for safe and reliable operation. If a LED control gear other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection umodule STARK SLE G2 must be supplied by a constant current LED control gear. Operation with a constant voltage LED control gear will lead to an irreversible damage of the module. Wrong polarity can damage the umodule STARK SLE G2. Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 5 LED light engine / OLED LED compact Umodule STARK SLE G2 LES26 CLASSIC ta tp If 25 °C 65 °C 700 mA 30 °C 65 °C 700 mA 65 °C 700 mA 40 °C 50 °C 65 °C 700 mA 25 °C 65 °C 1050 mA 30 °C 65 °C 1050 mA 40 °C 65 °C 1050 mA 50 °C 65 °C 1050 mA 25 °C 65 °C 1400 mA 30 °C 65 °C 1400 mA 40 °C 65 °C 1400 mA 50 °C 65 °C 1400 mA Rth, hs-a 2.76 K/W 2.41 K/W 1.70 K/W 1.00 K/W 1.68 K/W 1.46 K/W 1.03 K/W 0.60 K/W 1.16 K/W 1.01 K/W 0.71 K/W 0.40 K/W U Rth, hs-a 3.59 K/W 3.13 K/W 2.22 K/W 1.31 K/W 2.41 K/W 2.10 K/W 1.49 K/W 0.87 K/W 1.46 K/W 1.27 K/W 0.89 K/W 0.52 K/W O Umodule STARK SLE G2 LES23 CLASSIC ta tp If 25 °C 65 °C 500 mA 30 °C 65 °C 500 mA 40 °C 65 °C 500 mA 50 °C 65 °C 500 mA 25 °C 65 °C 700 mA 30 °C 65 °C 700 mA 40 °C 65 °C 700 mA 50 °C 65 °C 700 mA 25 °C 65 °C 1050 mA 30 °C 65 °C 1050 mA 40 °C 65 °C 1050 mA 50 °C 65 °C 1050 mA D Rth, hs-a 5.14 K/W 4.49 K/W 3.19 K/W 1.89 K/W 3.37 K/W 2.94 K/W 2.08 K/W 1.23 K/W 2.23 K/W 1.94 K/W 1.37 K/W 0.80 K/W PH AS E Umodule STARK SLE G2 LES19 CLASSIC ta tp If 25 °C 65 °C 350 mA 30 °C 65 °C 350 mA 40 °C 65 °C 350 mA 50 °C 65 °C 350 mA 25 °C 65 °C 500 mA 30 °C 65 °C 500 mA 40 °C 65 °C 500 mA 50 °C 65 °C 500 mA 25 °C 65 °C 700 mA 30 °C 65 °C 700 mA 40 °C 65 °C 700 mA 50 °C 65 °C 700 mA T Heat sink values Notes The actual cooling can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule STARK SLE G2 and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule STARK SLE G2 has to be fixed on the heat sink with M3 screws to optimise the thermal connection. Use of thermal interface material with thermal conductivity of l > 1 W/mK and layer thickness of interface material with max. 50 µm or a similar interface material where the quotient of layer thickness and thermal conductivity b < 50 µmmK/W. Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 6 LED light engine / OLED LED compact Thermal behaviour storage temperature operating temperature ta tp (at typ. current) tc max. (at typ. current)* max. humidity Condensation on the module is not allowed. During the processing of the LED modules in the lamp the humidity has to be between 30 and 70%. -30 ... +80 °C +25 ... +55 °C 65 °C 75 °C 0 ... 80 % * according to the derating curves 900 800 800 700 700 600 600 500 500 300 200 100 55 60 65 70 75 80 Tc [°C] 85 90 95 100 0 800 700 500 400 300 If [mA] If [mA] 600 200 100 55 60 65 70 75 80 Tc [°C] 85 90 95 100 PH 50 60 65 70 75 80 Tc [°C] 85 90 95 100 50 55 60 65 70 75 80 Tc [°C] 85 90 95 100 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 50 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 50 Data sheet 06/13-LED100-10 Subject to change without notice. 55 60 65 70 75 80 Tc [°C] 85 90 95 100 Derating curve for Umodule STARK SLE G2 LES23 CLASSIC 5,000 K If [mA] Derating curve for Umodule STARK SLE G2 LES23 CLASSIC 4,000 K If [mA] 55 Derating curve for Umodule STARK SLE G2 LES23 CLASSIC 3,000 K AS E 900 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 50 D 50 Derating curve for Umodule STARK SLE G2 LES19 CLASSIC 5,000 K 0 300 200 100 0 400 O 400 U 900 T Derating curve for Umodule STARK SLE G2 LES19 CLASSIC 4,000 K If [mA] If [mA] Derating curve for Umodule STARK SLE G2 LES19 CLASSIC 3,000 K www.tridonic.com 55 60 65 70 75 80 Tc [°C] 85 90 95 100 7 LED light engine / OLED LED compact Derating curve for Umodule STARK SLE G2 LES26 CLASSIC 3,000 K Derating curve for Umodule STARK SLE G2 LES26 CLASSIC 4,000 K 1600 1400 1400 1200 1200 1000 1000 800 800 600 400 400 200 200 50 55 60 65 70 75 80 Tc [°C] 85 90 95 0 100 Derating curve for Umodule STARK SLE G2 LES26 CLASSIC 5,000 K 1600 1400 1200 50 55 60 65 70 75 80 Tc [°C] 85 90 95 100 O 0 T 600 U If [mA] If [mA] 1600 D If [mA] 1000 800 600 400 50 55 60 65 70 75 80 Tc [°C] 85 90 95 100 PH 0 AS E 200 Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 8 LED light engine / OLED LED compact Lumen maintenance for HE operation operating time in h 80 70 50 80 70 50 80 70 50 80 70 50 > 50,000 > 50,000 > 50,000 > 50,000 > 50,000 > 50,000 50,000 > 50,000 > 50,000 42,000 > 50,000 > 50,000 25 55 65 75 T luminous flux in % U tp temperature in °C luminous flux in % operating time in h 80 70 50 80 70 50 80 70 50 80 70 50 > 50,000 > 50,000 > 50,000 43,000 > 50,000 > 50,000 37,000 > 50,000 > 50,000 31,000 50,000 > 50,000 25 55 65 AS E 75 D tp temperature in °C O Lumen maintenance for HO operation Luminous flux and operating current for LES19 at tp = 65 °C 3000 2500 lm 2000 1500 PH 1000 3000 K 4000 K 5000 K 500 0 0 100 200 300 400 mA 500 600 700 Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 800 9 LED light engine / OLED LED compact Luminous flux and operating current for LES23 at tp = 65 °C 4500 3000 K 4000 4000 K 3500 5000 K 3000 T lm 2500 2000 1500 U 1000 500 0 200 400 600 mA 800 1000 Luminous flux and operating current for LES26 at tp = 65 °C D 6000 5000 3000 2000 1000 0 AS E 4000 lm 1200 O 0 0 200 400 600 800 mA 1000 1200 1400 3000 K 4000 K 5000 K 1600 PH Relative forward voltage and relative luminous flux 1.05 1.14 1.12 1.1 1.03 rel. luminous flux [a.u.] relative voltage [a.u.] 1.04 1.02 1.01 1 0.99 1.06 1.04 1.02 1 0.98 0.96 0.98 0.97 20 1.08 0.94 30 40 50 tp [°C] 60 70 75 0.92 20 30 40 50 tp [°C] 60 70 75 The diagrams based on statistic values. The real values can be different. Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 10 LED light engine / OLED LED compact Wiring with housing Wiring without housing NTC solder pads + + red AWG 24 - black Removing wires by lightly pressing on the push button. D wire preparation: U Wiring type and cross section The wiring has to be solid cable with a cross section of 0.5 to 0.75 mm² or with flexible cable with soldered ends with a cross section of 0.5 mm². For the push-wire connection you have to strip the insulation (5 – 6 mm). 600 mm O 8 T NTC (if existing) – 5 – 6 mm Optical characteristics Umodule STARK SLE G2 AS E The optical design of the umodule STARK SLE G2 product line ensures optimum homogenity for the light distribution. Light distribution 100 60 40 20 -10° 0° 10° 20° 30° 40° -50° 50° -60° 60° 70° PH relative inetnsity [%] 80 -30° -40° -20° -90° 100 80 60 40 20 80° 0 20 40 60 80 100 90° Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 11 LED light engine / OLED LED compact Coordinates and tolerances according to CIE 1931 The specified colour coordinates are measured integral by a current impulse with nominal values of module after a settling time of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K y0 0,4041 0,4250 0,04 0,4200 0,035 0,4050 0,4000 0,3950 0,3900 4,000 K x0 0,3804 y0 0,3767 norm. intensity [W/nm] 0,4000 0,3950 0,3900 0,3850 PH 0,3600 0,3550 0,3800 0,3600 0,3750 0,3650 0,3700 0,3700 0,3650 0,3750 0,015 0,01 0 380 AS E Centre 0,3800 0,02 460 500 540 580 620 660 wave length [nm] 700 740 780 420 460 500 540 580 620 660 wave length [nm] 700 740 780 0,04 0,035 0,03 0,025 0,02 0,015 0,01 0,005 0 380 MacAdam ellipse: 3SDCM Data sheet 06/13-LED100-10 Subject to change without notice. 420 D 0,4600 0,4550 0,4500 0,4450 0,4400 0,4350 0,4300 0,4250 0,4200 MacAdam ellipse: 3SDCM 0,3850 0,025 0,005 0,3850 0,3900 0,03 U 0,4100 O norm. intensity [W/nm] 0,4150 0,3950 T x0 0,4369 Centre www.tridonic.com 12 LED light engine / OLED LED compact 5,000 K x0 0,3451 Centre y0 0,3516 0,06 0,3600 0,3550 0,3500 0,3450 0,3400 0,3350 0,3650 0,3600 0,3550 0,3500 0,3450 0,3400 0,3350 0,3300 0,04 0,03 0,02 0,01 0 380 0,3300 0,3250 0,05 T norm. intensity [W/nm] 0,3650 U 0,3700 420 500 540 580 620 660 wave length [nm] 700 740 780 PH AS E D O MacAdam ellipse: 3SDCM 460 Data sheet 06/13-LED100-10 Subject to change without notice. www.tridonic.com 13