Preview only show first 10 pages with watermark. For full document please download

Tankless Non-condensing Gts-910 Spec Sheet (scgss00210)

   EMBED


Share

Transcript

H E AV Y - D U T Y COMMERCIAL GAS HEAVY-DUTY COMMERCIAL GAS TANKLESS MODELS FEATURES SAFETY FEATURES Designed specifically for heavy-duty • Built in Freeze Protection commercial applications. Fully • Manual Reset Hi Limit (Set at 194°F) modulating, gas-fired, tankless, • Overheat Cutoff Fuse water heaters with sealed combustion • Inlet, Outlet & Mixing Thermistors and power-vented flue. for Constant Temperature Can be installed either indoors or Monitoring outdoors. Capable of supplying hot • Air Fuel Ratio Rod water for domestic hot water systems • GFI, Fuse & Surge Absorber (directly or indirectly) which can be • Power Supply Connection used with storage tanks, recirculations systems,hydronic heating systems, Venting and Combustion radiant floor heating systems, and/or • 5” Category III Stainless Steel combined domestic & heating • Vertical or Horizontal Installation applications (local codes dictate • 50’ Max Length, 5 elbows max proper compliance). (90° elbows = 5’ equivalent length) • Power Vent Primary Heat Exchanger • Electronic Ignition - No Pilot Light is Constructed of HRS35 • 5” Combustion Air Intake (with Commercial-Grade Copper GTS-910-NIE GTS-910-PIE GTS-910-NIEA GTS-910-PIEA • Stronger than standard copper and more resilient against erosion Continuous Maximum Flow Rates up to 14.5 GPM Easy-Link up to 4 Units • No multiple unit controller needed Combined Indoor/Outdoor Models Available in Natural Gas or Propane (LP) ASME Models Available optional kit) Optional Accessories • Multi-Unit Controller (Multi-Unit System) • Remote Temperature Controller • Direct Vent Conversion Kit • Pipe Cover • Vent Cap • Backflow Preventor Warranty • 5-year limited warranty on heat exchanger in commercial applications •5-year limited warranty on all parts Low NOx Emissions ANSI Z21.10.3 CSA 4.3 Complies with Lead Free Standards For more information on Tankless Condensing Units, contact: State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015 1-877-737-2840 Toll-free USA www.statewaterheaters.com 251201_SCGSS00210.indd 1 SCGSS00210 Revised October 2012 10/23/12 3:35 PM H E AV Y - D U T Y COMMERCIAL GAS HEAVY-DUTY COMMERCIAL GAS TANKLESS GAS CONSUMPTION INPUT MODEL NUMBER FUEL TYPE MIN. BTU/H MAX. BTU/H INLET GAS PRESSURE THERMAL EFFICIENCY MIN. W.C. DIMENSIONS (INCHES) MAX. W.C. GPM** HEIGHT WIDTH DEPTH VOLT AMP FLUE*** INTAKE (OPTIONAL) HOT/COLD GAS CONN. APPROX. SHIPPING WEIGHT (LBS) 25-3/10 24-4/5 11-4/5 25-3/10 24-4/5 11-4/5 25-3/10 24-4/5 11-4/5 25-3/10 24-4/5 11-4/5 All dimensions in inches. *ASME models **Current numbers based on factory testing, 0.4 GPM required for continuous fire after initial ignition. *** Category III required 15 - 150 psi water pressure. Pressure only relief valve requires (Min. 380,000 BTUs. 150 PSI). Min 40 PSI or above recommended for maximum flow. CLEARANCES: Flow Rate Vs. Temperature Rise INDOOR: Top 12”, Bottom 12”, Front 24”, Back 0.5”, Sides 2” OUTDOOR: Top 36”, Bottom 12”, Front 24”, Back 0.5”, Sides 2” 16 Flow Rate (gpm) 14 12 10 24-7/8" (632.9mm) 12-1/4" (311.5mm) 8 15" (381mm) 4-7/8" (122.9mm) 6 8" (203mm) 1/2" (11.9mm) 5" (127mm) 4 2 0 85 105 125 145 Temperature Rise (°F) Set temperature of 145° or lower Set temperature of 150° or higher 25-1/4" (642mm) Above shown rate is based on single unit only Pressure Loss 25 40 15 30 10 20 5 10 Head Feet Pressure Loss (psi) 50 20 28-7/8" (734mm) 65 2-1/2" (62.1mm) 45 25 1/2" (12.5mm) 4-3/8" (110.8mm) GAS 0 0 5.0 0.0 10.0 15.0 Flow Rate (gpm) Set temperature of 145° or lower 5-3/8" (137.3mm) HOT 1-5/8" (40mm) COLD 6-3/4" (171.3mm) 120V 5-7/8" (150mm) HOT 4" (100mm) 120V 7-3/8" (186mm)GAS 7-5/8" (194.3mm) COLD Set temperature of 150° or higher Specification Water heater(s) shall be Model _________________ as manufactured by State Water Heaters. The water heater(s) shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. The heater shall be vented with 5” Stainless steel Category III vent pipe a distance not to exceed 50’ (equivalent) feet terminating vertically or horizonatlly as prescribed. Intake air with optional direct vent kit may be of such material as PVC not to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by on board solid state printed circuit board monitoring incoming and outgoing temperatures with factory-installed thermistors, sensing and controlling flow rate to set point temperature with control both air and gas mixture inputs to maintain thermal combustion efficiency. Unit also consists of ground fault interrupter, inline fusing, spark ignition and sensor system, aluminized stainless steel burners, air-fuel ratio rod, Hi limit switch, modulating and proportional gas valves, freeze protection sensor and heating block and overhead cutoff fuses.The water heater(s) shall be CSA listed, exceeds the energy efficiency requirements of ASHRAE 90.1b-1992 and complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for low NOx emissions. For complete information on limited warranties, consult written warranty or contact technical support at 1-877-737-2840. State Industries, Inc., reserves the right to make product changes or improvements without prior notice. For more information on Tankless Heavy-Duty Commercial Units, contact: State Water Heaters 500 Tennessee Waltz Parkway Ashland City, TN 37015 1-877-737-2840 Toll-free USA www.statewaterheaters.com SCGSS00210 251201_SCGSS00210.indd 2 Revised October 2012 © 2012 State Industries, Inc. Printed in U.S.A 10/23/12 3:35 PM