Preview only show first 10 pages with watermark. For full document please download

Tcil Instructions Pg 1 2008

   EMBED


Share

Transcript

TCIL TRAFFIC CONTROLLER INDICATOR Installation Instructions (For LED Light Engines, Horizontal or Vertical Units) Standard Wall Mount 1. Remove the cover from the housing by unscrewing the four retaining screws on the front of the unit. 2. Carefully remove the raceway by unscrewing the two screws located between the sockets. 4. Mount the housing securely to the building structure using four appropriate fasteners (not supplied). 3. Using a screwdriver knock out the holes in the housing for screws and conduct. 5. Make wiring connections, see diagram below for optional control switch. 6. Attached raceway with the two screws removed, install supplied LED light engine(s), and replace the cover and four retaining screws. Light Engines Note: Make appropriate wiring connections per local codes. Optional Control Switch - Wiring Schematic Wiring diagram for teller control switch with three position switch and green and red indicator lights. Front View Back View White (Neutral Lead) Green Light (Open) Green Light (Open) Black (Open Lead) 3 Position Switch 3 Position Switch Red (Closed Lead) Red Light (Closed) Red Light (Closed) White Black Ground For Supply Connections Use Wire Rated For At Least 110º C 120 Volts 0.6 Amps Replace with LED Light Engines Ground (To Sign) Traffic Controller From Supply Current TCIL 0908 LMY Projection, Ceiling, Recessed, and Angle Mounts • Remove the cover of the TCIL unit by unscrewing the four retaining screws on the front of the unit. • Remove the raceway by unscrewing the two screws located between the sockets. • Secure the mounting bracket (Angle, Ceiling or Projection) to the building surface using appropriate fasteners (not supplied). • Using a screwdriver, knock out the holes in the housing for screws and conduit. Attach the unit housing to the mounting bracket using appropriate fasteners (not supplied). • Make wiring connections (see diagram). Replace the raceway using the screws removed in step 2, install supplied LED light engines, and replace the cover and four retaining screws. • Secure Recessed Frame to TCIL unit with 4 screws, insert frame / unit assembly into wall opening, attach frame to wall surface using appropriate fasteners (not supplied). Projection Mount Ceiling Mount Canopy Wall Surface Angle Mount Canopy Top View Recessed Frame Top View Wall Opening Canopy Ceiling Bracket Projection Bracket Unit Canopy 45º 30º Unit Unit Unit Note: Make appropriate wiring connections per local codes. Center Post Mount • Laying post on the ground, slide TCIL unit with attached mounting extrusion into the post slot. • Align the mounting extrusion just under the conduit hole in the post and tighten the set screw in the mounting extrusion. • Fasten the post cap on top of the post with the two screws provided. Dig hole to local code, insert post and fill with concrete Level sign both hortizontally and vertically. • Follow the wall mount instructions on the opposite side for accessing and wiring the unit. Conduit or other appropriate wire enclosure (Not Supplied) Unit Unit Set screw in mounting extrusion Slot in mounting post Set Screw Mounting Extrusion Mounting extrusion Hole for conduit Standard Rectangular Mounting Post Note: Make appropriate wiring connections per local codes. TCIL 0908 LMY