Tdls220 Bulletin

   EMBED


Share

Transcript

TDLS220 Process Oxygen Analysis The Tunable Diode Laser Spectroscopy (TDLS) Analyzer, TDLS220 is specifically designed for accurate, reliable and low maintenance measurement of volume percent (vol%) oxygen in process gas streams. Typical applications include: • Vent headers and flare lines • Vapor Recovery Systems • Reactor Control Bulletin 11Y01B02-01E-A www.yokogawa.com/an/index.htm The first tunable diode laser analyzer, designed specifically for process analysis Innovative Dependable Accurate Process Hardened Our TruePeak Process Laser Analyzer uses a tunable diode laser and measures across an infrared absorbance region. This means you can make measurements in the most demanding applications. The TruePeak measurement integrates the area of the absorbance rather than measuring peak height or peak width value alone. This means you get a true interference free analysis. TruePeak measurement ensures accuracy even during simultaneous sample pressure, temperature, and background gas changes. Flexible installation options, materials of construction, and validation methods make the Yokogawa TDLS a perfect solution for the most aggressive process applications. User Interface 4Stand Alone • Mini Display (integral or remote), 4x20 VFD with • scrolling information 7” Color Screen with Keypad 4Remote Interface Unit (RIU) • Interface only, not required for analyzer operation • 7” Color Screen with Keypad • Connects 1 to 4 analyzers with central display/keypad Reliability 4Enhanced Diagnostics Built In diagnostics with on board CPU, data storage, and retrieval. No PC required to record data, spectra, and critical diagnostics. • Data transfer via wired/wireless Ethernet, memory stick or PDA • Spectra capture (timed, manual capture, event-based) 4Maintenance • All components field replaceable • Remote diagnostics and analyzer control Sample Diagnostics Screen Shots The Process TDLS Solution 4Interference free 4TruePeak measurement 4Rapid measurement up to 5 seconds (optional 10 seconds) 4Sample gas pressure up to 100 psig 4Sample gas temperature up to 120˚C (248˚F) (When ambient temperature is ≤ 40˚C) 4Optical measurement Hazardous Area 4 Class 1, Div 2 Group B,C,D when purged • The standard analyzer is designed for operation in Safe Area (General Purpose) The addition of a Purge System facilitates operation in Hazardous Area for gaseous releases. Communications 4Wired • Analog Outputs (3, 4-20mA) • Digital Outputs (Warnings/Faults/Alarm + 3x Valve Control) Ethernet (standard) • USB Data Transfer (standard) • Other Options Available • 4Wireless - Optional Wireless • WiFi 802.11 4Fully Network Ready Process Oxygen Analysis Designed as an extractive analyzer to replace traditional extractive analyzer technologies. • Line Power Input (VAC) • Integral Heat Trace Controller • Heat Traced and Insulated Flow Cell • Flow Cell construction 316L or (optional) monel alloy 400 and Kalrez 4079 0-rings Refinery Oxygen measurement is critical in many refining applications to ensure safety, increase efficiency, and enhance process control. The TDLS220 was designed to provide a near real time measurement that is unaffected by background interferences. Application include but not limited to marine vapor recovery, flare headers, flare gas recovery drums and waste gas from a gas plant. technical specifications Accuracy Detection Limit 0.01% O2 Span Drift (6-12month calibration) <+/-0.1% O2 Zero Drift (6-12month calibration) <+/-0.05% O2 Linearity R2 = 0.9999% Ambient Temperature -10 + 50˚C (14-122˚F) Analog I/O (optional) Outputs: Concentration/Transmission (3@ 4-20mA isolated) Sub 4mA for warnings/faults Inputs: Pressure/Temperature Feed for Compensation (2@4-20mA isolated, powered or loop power) Digital I/O Outputs: Inputs: Area Classification General purpose. Class 1 Division 2 Group B,C and D with purge. ATEX and CE pending. CSA acceptance by request. Zone 1 and Div1 require a special Communications Ethernet, IEEE 802.3, 10/ WiFi 802.11 (optional) Automatic USB data transfer (upload/download settings and data) Calibration Recommended Calibration Check Interval 3-6 Months •Warning/Fault/Concentration Limit Relays (3 Form C Relay SPDT rated 1A@24VDC) •Valve Control (3@24VDC, Max 10W per valve), zero/span/ Remote Validation (3 voltage free floating contacts) for zero/span/ GasES MEASURED O2 Max Range 0-25%, Min Range 0-1% Detection Limits, accuracy, etc. are application dependant. Yokogawa Electric Corporation World Headquaters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN Tel: +81-422-52-6316 Fax: +81-422-52-6619 http://www.yokogawa.com/an/ North America Yokogawa Corporation of America Georgia, U.S.A http://www.yokogawa.com/us South America Yokogawa Corporation of America Brazil http://www.yokogawa.com.br/ Yokogawa Europe B.V. European Headquarters The Netherlands http://www.yokogawa.com/eu/ Yokogawa Electric CIS LTD Russian Federation http://www.yokogawa.ru/ Contact Yokogawa for more details Middle East Yokogawa Middle east B.S.C. (C) http://www.yokogawa.com/bh/ India Yokogawa India LTD. http://www.yokogawa.com/in/ Singapore Yokogawa Engineering Asia PTE. LTD. http://www.yokogawa.com/bh/ Australia Yokogawa Australia PTY. LTD. http://www.yokogawa.com/au/ Korea Yokogawa Electric Korea CO., LTD. http://www.yokogawa.com/kr/ China Yokogawa China CO., LTD. http://www.yokogawa.com/cn/ Yokogawa Shanghai Instrumentation CO., LTD. http://www.ysi.com/cn/ Yokogawa Sichuan Instrument CO., LTD. http://www.cys.com/cn/ Taiwan Yokogawa Taiwan Corporation http://www.yokogawa.com.tw/ Represented by: Vig-PMK-G-NL-10E Printed in USA, 107 (KP) [Ed 02b] Bulletin 11Y01B02-01E-A Subject to change without notice. All rights Reserved, Copyright © 2009, Yokogawa Corporation of America