Preview only show first 10 pages with watermark. For full document please download

Tdr-960-spec 21.10.2015

   EMBED


Share

Transcript

960W Three Phase Industrial DIN RAIL with PFC Function TDR-960 series ■   ‧           ‧   ‧       ‧       ‧           ‧     ‧     ‧         ‧   ‧    ‧     ‧     ‧     ‧   SPECIFICATION MODEL OUTPUT TDR-960-24 TDR-960-48 DC VOLTAGE RATED CURRENT 24V 40A 48V 20A CURRENT RANGE 0 ~ 40A 0 ~ 20A RATED POWER 960W 960W RIPPLE & NOISE (max.) Note.2 180mVp-p 250mVp-p VOLTAGE ADJ. RANGE 24 ~ 28V VOLTAGE TOLERANCE Note.3 ±1.0% 48 ~ 55V ±1.0% LINE REGULATION ±0.5% LOAD REGULATION SETUP, RISE TIME ±1.0% 1000ms, 100ms/400VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPU T 12ms / 400VAC ±1.0% 800ms, 100ms/500VAC at full load 14ms / 500VAC at full load Note.4 Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC FREQUENCY RANGE POWER FACTOR (Typ.) 47 ~ 63Hz PF≧ 0.88/400VAC EFFICIENCY (Typ.) 94% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/400VAC 1.4A/500VAC COLD START 60A LEAKAGE CURRENT PF≧0.86/500VAC at full load 94.5% <3.5mA / 530VAC 105 ~ 130% rated output power OVERLOAD Pro tection type : Constant current limiting, unit will shut down after 3 sec. ,re-p ower on to recover PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION ±0.5% 29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover 56 ~ 65V 90℃ ±5℃ (TSW) detect on heatsink of power switch 85℃± 5℃ (TSW) detect on heatsink of power switch Pro tection type : Shut down o/p voltage, recovers automatically after temperature goes down DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load Please refer to function manual CURRENT SHARING WORKING TEMP. WORKING HUMIDITY Note.5 -30 ~ +70℃ (Refer to "Derating Curve") 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS -40 ~ +85℃, 10 ~ 95% RH SAFE TY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION I/P-O/P:3KVAC OTHERS UL508 approved, IEC60950-1 CB approved by SIQ I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A MTBF 59.4K hrs min. DIMENSION 110*125.2*150mm (W*H*D) 2.47Kg ; 6pcs/15.8Kg/1.47CUFT PACKING NOTE ±0.03%/℃ (0 ~ 50℃) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 MIL-HDBK-217F (25℃)                  ℃                                                                                                                           File Name:TDR-960-SPEC 2013-04-26 TDR-960 series 960W Three Phase Industrial DIN RAIL with PFC Function Mechanical Specification Case No.214A Unit:mm 123 4 1 25 .2 CN205 12 34 1 2 3 4 5 6 TB1 1 2 3 4 TB2 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Termina l Pin No. Assignment (TB1) Pin No. 1 2 3 4 Te rminal P in No. Assignment (TB2) Assignm ent FG AC/L3 AC/L2 AC/L1 Pin No. 1,2 ,3 4,5,6 Assignment DC OUTPUT +V DC OUTPUT -V Control Pin (CN205 ) : DINK LE ECH250R-04P or equival ent Pin No . Assignment 1 P-( Current Share) 2 P+( Current Share) 3,4 DC OK Relay Cont ac t Mating Housing Wi re Diameter DINKLE ESC250V-04P or equivalent (Including in the single package) Block Diagram 0.081~0.517mm2 (28~20AWG) PFC fosc : 65KHz PWM fosc : 60KHz DC OK I/P EMI FILTE R & RE CTIFIERS POWER SWITCHING PFC CIRCUIT RECTIFIERS & F ILTER +V -V O .C.P. O.L.P. FG P WM CO NTROL PFC CO NTROL DETECTION CIR CUIT CURRENT S HARE O.T.P. CURRENT SHARE O.V.P. DC OK Relay Contact Contact Close P SU turns on / DC OK. Contact Open P SU turns off / DC Fail. Contact Ratings ( max .) 30V/1A res istive load. File Name:TDR-960-SPEC 2013-04-26 TDR-960 series 960W Three Phase Industrial DIN RAIL with PFC Function Derating Curve Output derating VS input voltage 100 100 Three phase operation 90 80 80 60 Dual phase operation(L1 & L3) 70 60 40 Dual phase operation(L1 & L2 or L2 & L3) 50 20 40 -30 0 10 20 30 40 50 60 70 (VERTICAL) 340 360 AMBIENT TEMPERATURE (℃) 380 400 450 500 550 INPUT VOLTAGE (V) 60Hz Function Manual 1. Current sharing (1) Parallel operation is available by connecting th e units shown as below (P+,P- are connected m utually in parallel). (2) Difference of output voltages among parallel units should be less than 0.2V. (3) The total output current must not exceed the v alue determined by the following equation (Outp ut current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel ope ration 4 units is the maximum, please consult th e manufacture fo r other applications. (5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. (6) When in parallel operation, the minimum output load should be greater than 5% of total output load. (Min. load >5% rated current per unit x number of unit) (7) In parallel connection, maybe only one unit (m aster) operate if the total output load is less than 5% of rated loa d condition. The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on. (8) Some minor noise may be heard at light load condition under parallel operation. This is a normal phenomenon and the performance of the PSU will not be influenced. LOAD +V -V P+ and P- lines shoul d be tw isted in pairs P+(pin2) DCO K 4 DCO K 3 P+ 2 P- 1 CN2 05 DCOK 4 DCOK 3 P+ 2 P- 1 CN205 +V -V TB2 +V -V TB2 PSU P-(pin1) DC OK 4 DC OK 3 P+ 2 P- 1 C N20 5 +V -V TB2 PSU DC OK 4 DC OK 3 P+ 2 P- 1 CN 20 5 +V -V TB2 PSU PSU File Name:TDR-960-SPEC 2013-04-26